Loading...
HomeMy WebLinkAboutSW8950109_Compliance Evaluation Inspection_20160728 PAT McCRORY Governor DONALD R. VAN DER VAART Secretary Energy,Mineral& T RA CY DAVIS Land Resources ENVIRONMENTAL QUALITY July 28, 2016 Georgetowne Homeowners' Association, Inc. C/o Kyle Berzina, Director, CEPCO CEPCO 1628 Doctors Circle Wilmington,NC 28401 Subject: Notice of Inspection—Compliant Georgetowne Subdivision State Stormwater Management Permit No. SW8 950109 New Hanover County Dear Mr. Berzina: On July 26, 2016, staff from the Wilmington Regional Office of the Division of Energy, Mineral and Land Resources (DEMLR)reviewed the file for Georgetowne Subdivision, located in New Hanover County to determine the status of compliance with the State Stormwater Management Permit Number SW8 950109, originally issued on May 9, 1995 and as modified thereafter. DEMLR file review has revealed that the site is in compliance with the terms and conditions of this permit. Please find a copy of the completed form entitled "Compliance Inspection Report" attached to this letter,which summarizes the findings of the recent inspection. As indicated in the attached report,the following deficiencies have been resolved: 1. A valve was installed on the unapproved discharge pipe, which is located under the emergency overflow riprap area of Pond#l. This gate valve was used to plug the discharge pipe, so it should always be in the closed position and locked. However, if it needs to be opened later for some reason(i.e.-to drain the pond or change the level), it can be done upon approval by DEQ State Stormwater. 2. Pictures have been submitted as verification for installation of the valve described above, and equalizer pipes, which were previously installed at an earlier date. Please be advised that until you submit the required Name/Ownership Change Form to the Division and receive approval from the Division to transfer the permit, you are required to comply with the terms, conditions and limitations of the Stormwater Management Permit under Title 15A North Carolina Administrative Code 2H .1003 and North Carolina General Statute 143-214.7, including the operation and maintenance of the permitted stormwater system. Please also note that any individual or entity found to be in noncompliance with the provisions of a stormwater management permit or the stormwater rules is subject to enforcement action as set forth in NCGS 143 Article 21, including the assessment of civil penalties of up to $25,000 per day. State of North Carolina I Environmental Quality I Energy,Mineral and Land Resources Wilmington Regional Office j 127 Cardinal Drive Extension( Wilmington,NC 28405 910 796 7215 State Stormwater Permit No. SW8 950109 Page 2 of 2 If you have any questions,please contact me at the Wilmington Regional Office,telephone number (910) 796-7215 or via email at steven.pusey@ncdenr.gov. Sincerely, Steve Pusey Environmental Engineer Enc: Compliance Inspection Report /-j GDS\sgp: %Stormwater\Permits &Projects\1995\950109 HD\2016 07 CEI_compliant 950109 cc: Edward Coleman, Retention Pond Services 3317 Masonboro Loop Rd - Suite 150, Wilmington,NC 28408 Paul Mazzola, President, Georgetowne HOA 4217 Aftonshire Dr., Wilmington, NC 28412 Georgette Scott, Wilmington Regional Office Stormwater Supervisor WiRO Stormwater Permit File State of North Carolina I Environmental Quality I Energy,Mineral and Land Resources Wilmington Regional Office 1 127 Cardinal Drive Extension I Wilmington,NC 28405 910 796 7215 Compliance Inspection Report Permit: SW8950109 Effective: 10/09/15 Expiration: 02/09/23 Project: Georgetowne Subdivision Owner: Georgetowne Homeowners Association County: New Hanover Adress: 4200 S College Rd Region: Wilmington City/State/Zip: Wilmington NC 28412 Contact Person: Cathie Johnston Title: President Phone: 910-392-7201 Directions to Project: College Road,just south of Cape Fear Academy Type of Project: State Stormwater-HD-Detention Pond Drain Areas: 1 -(Barnards Creek) (03-06-17)(C;Sw) On-Site Representative(s): Related Permits: Inspection Date: 07/26/2016 Entry Time: 05:OOPM Exit Time: 05:30PM Primary Inspector: Steven G Pusey Phone: Secondary Inspector(s): Reason for Inspection: Follow-up Inspection Type: Transfer Renewal Permit Inspection Type: State Stormwater Facility Status: Compliant ❑ Not Compliant Question Areas: i State Stormwater (See attachment summary) page: 1 Permit: SW8950109 Owner-Project: Georgetowne Homeowners Association Inspection Date: 07/26/2016 Inspection Type Transfer Renewal Reason for Visit: Follow-up Inspection Summary: This site meets the requirements for compliance with the permit. File Review Yes No NA NE Is the permit active? ® ❑ ❑ ❑ Signed copy of the Engineer's certification is in the file? ® ❑ ❑ ❑ Signed copy of the Operation&Maintenance Agreement is in the file? ® ❑ ❑ ❑ Copy of the recorded deed restrictions is in the file? ® ❑ ❑ ❑ Comment: SW Measures Yes No NA NE Are the SW measures constructed as per the approved plans? ■ ❑ ❑ ❑ Are the inlets located per the approved plans? . ❑ ❑ ❑ Are the outlet structures located per the approved plans? 0 ❑ ❑ ❑ Comment: As requested,a valve was installed on the discharge pipe under the riprap at Pond#1 in order to stop the pond from short-circuiting. The valve installation was verified by photos Also the installation of equalizer pipes between ponds was verified by photos Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? N ❑ ❑ ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to ❑ ❑ ❑ DWQ upon request? Comment: Ponds are being maintained on a regular basis page: 2 Non W 11 Work Completion R,po,i p.,3 of I I.jpg STORMWATER COMPLIANCE OPERATIONS WORK COMPLETION REPORT Site Photos 3 4. zw Description Description Description Description Picture shows Pond#2 (OCS Side) at normal pool. s� r: R w yrG e �,' - ,.. f•� ..,-'����.'�.'�` db?4�Sazs?': 1'� 44�;,: ,F�� � .� � w"' x Y,s'ems n'`".+. . 3-�ry,��v�C� O'�1.��',rYa�• 3 3"'0�`{�.cs.� -',L W f , d * IH '�' _ _ + � .t s c,. _ w 4 51, eM. Lj r r s Picture shows all three pipes on the discharge side. (1)The metal pipe shown on the plans; (2) and (3) are the HDPE pipes shown on the plans that run between the ponds.The pipe that was briefly bent upward by someone was pushed back down by RPS. Pusey, Steven From: Abby Stanley <abby@retentionponds.com> Sent: Tuesday,July 26, 2016 3:07 PM To: Edward Coleman; Pusey, Steven Subject: RE: Georgetowne Attachments: Georgetowne Valve.pdf Good afternoon Steve, I have attached photos of the valve installed. Please let us know if you need anything else. Thank you, Abby Stanley Senior Estimator&Project Manager Office(910) 313-6830 1 Mobile(910)297-9735 This e-mail transmission, including any attachments, is intended only for the named recipient(s) and may contain information that is privileged, confidential and/or exempt from disclosure under applicable law. If you have received this transmission in error,or are not the named recipient(s), please notify Retention Pond Services, Inc. immediately by return e-mail and permanently delete this transmission, including any attachments. From: Edward Coleman Sent:Tuesday,July 26,2016 10:50 AM To: Pusey,Steven<steven.pusey@ncdenr.gov> Cc:Abby Stanley<abby@ retention ponds.corn> Subject: Re:Georgetowne Yes Sir. I am on the road today but will get you some pics in the morning.Thanks. Edward. Sent from my Whone On Jul 26, 2016,at 10:43 AM, Pusey,Steven<steven.pusey@ncdenr.gov>wrote: Ed, Hello, I hope all is well with you. Did you get the valve installed yet? Steve From: Edward Coleman [mailto:Edward@retentionponds.com] Sent: Monday,June 13, 2016 1:49 PM To: Pusey,Steven<steven.pusev@ncdenr.gov> Subject: RE:Georgetowne 1 Pusey, Steven From: Edward Coleman <Edward@retentionponds.com> Sent: Monday, June 13, 2016 1:49 PM To: Pusey, Steven Subject: RE: Georgetowne Steve, Thanks for the email. We had to wait on the valve which we received last week. We are wrapping up a job in town this week and the Georgetowne job is next on the list.The job should be completed this week. I will keep you posted. Thanks. Edward Retention Fond 67ervices 3317 Masonboro Loop Rd -Suite 150 Wilmington, NC 28409 910-313-6830 ext 117 910-313-6870 Fax 910-443-9341 Cell www.retentionponds.com From: Pusey,Steven [mailto:steven.pusey@ncdenr.gov] Sent: Monday,June 13, 2016 8:51 AM To: Edward Coleman<Edward@ retentionponds.com> Subject: RE:Georgetowne Ed, Just checking on the status of the valve installation at the pond overflow riprap area for Georgetown Subdivision. Has that been done yet? Please advise the status. Thanks, Steve 0. PuU,-V Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven.pusey -ncdenr.gov 1 ST TE OF NORTH CAR®T.,WA Department of Environmental anal Natural Resources 127 Cardinal Drive Extension. Wjmington,North Carolina.28405 (910)795-7215 FILE ACCESS Tt1 C�� � L CId h SECTION .� V,,'' TIIviE/DATI; NA&M REPMENTING Guidelines forAccess: The staff of VJ"jagtan Regional Office is dedicated to making puBc records in. aux custodyreadzly a�railable to tlae public far review and capyirtg. W'also have dne res obsibility to the public to safeguard these records and to ca€xy out our day-to-day program oblf gations. Please read carefully fie following guidelines signing the form' 11 Due to tlae large public- emand for file aceess,we mgii%tthatyou can at least a day in advance to schedule an.appoh3tmennt to review the files. Appointments vPtll Tae schaduTed between 9i004m and 3:0 Viewing time earls at 4:45pm, Aa pane arrt�in withaut a rrWoittment Mg view the Meg to the extent that t)je and staff snpe-'MR1an Ss yaiTable. 2. You must specify files you want to review.by La AM name. The number of fides that you may review at oue fte will be linnited to five. ts 3. You may mare copies of a file when the copier is not in use by the staff and if time pemni Cost par copy is$,05 cents,payment may be made lr eheek,money order.or eash at the reeetatiio>tz desk, Copies totaT� $S 00 or more can be invaiced for...our eon�enxenee. 4_ FILES I�TTJST T AT 3Cbt 4)R DF,R YOU T?Di7I-' M.'Piles may not be taken from the offee,-To remove,alter,deface,m-utilate,or destroy Matenal in one of these files is a misdemeanor for which you cab.be fuaed up to$500,00. No briefcases lame totes etc.ate- ermztted in the file review area. S. In accordance with General Statao 25-3-512,a$25,00-proce5sing fee-will be clnarg�d and oollected•for checks on which paymeaat has been.refused. PA CTIsrr AID COUNTY 2 4. Signature d 14amo of FkM/Susiraess 4D /0 Time In Time Out Please azaelz a budness ccu d.,tois fa)r M COPIES MADE PMD rnr 01.CE 5:.�. .i�..f�e acce • Pusey, Steven From: Edward Coleman <Edward @retentionponds.com> Sent: Tuesday, March 15, 2016 3:29 PM To: Pusey, Steven Cc: Kyle Berzina Subject: Georgetowne Attachments: Georgetowne Pipe Pictures.docx Steve, Attached are some pictures that show the pipes at Georgetowne.We are working with our pipe suppliers to get the appropriate valve for the discharge pipe at the spillway. I anticipate having a proposal to Georgetowne this week. Thanks and please let me know if you need anything further from us. I will keep you updated on the valve installation. Edward Coleman Retentiom POnd Services 3317 Masonboro Loop Rd-Suite 150 Wilmington,NC 28408 910-313-6830 ext 117 910-313-6870 Fax 910443-9341 Cell www.retentionponds.com k � PAT MCCRORY th Governor DONALD R. VAN DER VAART L, Secretary Energy,Mineral and Land Resources TRACY DAVIS ENVIRONMENTAL QUALITY Director March 3, 2016 6 Georgetowne Homeowners' Association, Inc. c/o Kyle Berzina, Director, CEPCO CEPCO 1628 Doctors Circle Wilmington,NC 28401 ; c Subject: Notice of Inspection—loot Compliant Georgetowne Subdivision State Stormwater Management Permit No. SW8 950109 New Hanover County A Dear Mr. Berzina: E On March 2, 2016, staff from the Wilmington Regional Office of the Division of Energy, Mineral and Land Resources (DEMLR) inspected Georgetowne Subdivision, located in New Hanover County to determine the status of compliance with the State Stormwater Management Permit Number SW8 950109, originally issued on May 9, 1995 and as modified thereafter. DEMLR file review and site inspection revealed that the site is not in compliance with the terms and conditions of this permit. Please find a copy of the completed form entitled "Compliance Inspection Report" attached to this letter, which summarizes the findings of the recent inspection. As indicated in the attached inspection report,the following deficiencies must be resolved: 1. Please install a valve on the unapproved discharge pipe,which is located under the emergency overflow riprap area of Pond#1. A die test was performed and the results confirmed that the outlet pipe under the emergency overflow riprap is draining the pond. This is considered short-circuiting the pond. Therefore,this pipe needs to be plugged. Since this will change the overall performance of the pond, it has been proposed that the pipe be plugged with a gate valve in the closed position and locked. Then, if it needs to be opened later for some reason(i.e.- to drain the pond or change the level), it can be done. However,please note that this will require approval by DEQ State Stormwater first. 2. Please submit pictures of the drained pond showing the equalizer pipes installed. The equalizer pipes could not be located in the field due to murky water. 1 Please be reminded that it is your responsibility as the permittee of record to submit a completed and signed Name/Ownership Change Form to the Division of Energy, Mineral and Land F Resources at least 30 calendar days prior to making any of the below listed changes. These forms are available on our website at: littps:Hdeq nc gov/about/divisions/energy-mineral-land- resources/energy-mineral-land-permits/stormwater-permits/forins. K a. An ownership change including the sale or conveyance of the permitted project area in whole or in part. This does not include the conveyance of subdivided residential lots to individuals which are made subject to a recorded declaration of covenants and restrictions as required by the stormwater permit; b. The sale or conveyance of the common areas to a Homeowner's or Property Owner's Association, subject to the requirements of Session Law 2011-256; c. Foreclosure proceedings; e State of North Carolina I Environmental Quality I Energy,Mineral and Land Resources t 127 Cardinal Drive Extension I Wilmington,NC 28405 ' 910 796 7215 T 1 910 350 2004 F I htto://t)ortal.ncdenr.ory(web/Ir/ i State Stormwater Permit No. SW8 950109' Page 2 of 2 d. Bankruptcy; e. Dissolution of the partnership or corporate entity; f. A name change of the owner/permittee; g. A name change of the project; h. A mailing address change of the permittee; Please be advised that until you submit the required Name/Ownership Change Form to the Division and receive approval from the Division to transfer the permit,you are required to comply with the terms, conditions and limitations of the Stormwater Management Permit under Title 15A North Carolina Administrative Code 2H .1003 and North Carolina General Statute 143-214.7,including the operation and maintenance of the permitted stormwater system. Failure to provide the requested information, or to respond to this letter with a plan of action, including a timeline to resolve the identified deficiencies, by April 1,2016, are considered violations of the permit. If the requested information is not submitted to this office by the due date,then DEMLR staff will re-inspect the site and may issue allotice of Violation. Please also note that any individual or entity found to be in noncompliance with the provisions of a stormwater management permit or the stormwater rules is subject to enforcement action as set forth in NCGS 143 Article 21,including the assessment of civil penalties of up to$25,000 per day. If you have any questions,please contact me at the Wilmington Regional Office,telephone number(910) 796-7215 or via email at steven.pusey@ncdenr.gov. Sincerely, Steve Pusey Environmental Engineer Enc: Compliance•Inspection Report GDS\sgp: %Stormwater\Permits &Projects\1995\950109 HD\2016 03 CEI_deficient 950109 cc: Edward Coleman, Retention Pond Services 3317 Masonboro Loop Rd - Suite 150, Wilmington,NC 28408 Paul Mazzola, President, Georgetowne HOA 4217 Aftonshire Dr., Wilmington,NC 28412 Georgette Scott, Wilmington Regional Office Stormwater Supervisor WiRO Stormwater Permit File i i i f State of North Carolina I Environmental Quality I Energy,Mineral and Land Resources 127 Cardinal Drive Extension I Wilmington,NC 28405 910 796 7215 T 1 910 350 2004 F I htto://vortal.ncdenr.ore/web/lr/ C®mpBiance Inspection Report Permit: SW8950109 Effective: 10/09/15 Expiration: 02/09/23 Project: Georgetowne Subdivision Owner: Georgetowne Homeowners Association County: New Hanover Adress: 4200 S College Rd Region: Wilmington City/State/Zip:Wilmington NC 28412 Contact Person: Cathie Johnston Title: .President Phone: 910-392-7201 Directions to Project: College Road,just south of Cape Fear Academy Type of Project: State Stormwater-HD-Detention Pond Drain Areas: 1 -(Barnards Creek) (03-06-17)(C;Sw) On-Site Representative(s): Related Permits: Inspection Date: 03/02/2016 Entry Time: 10:OOAM Exit Time: 11:OOAM Primary Inspector: Steven G Pusey Phone: Secondary Inspector(s): Reason for Inspection: Follow-up Inspection Type: Transfer Renewal Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant Not Compliant Question Areas: State Stormwater (See attachment summary) page: 1 Permit: SW8950109 Owner•Project: Georgetowne Homeowners Association Inspection Date: 03/02/2016 Inspection Type Transfer Renewal Reason for Visit: Follow-up Inspection Summary: In order to bring this project into compliance,the following actions need to be taken: 1. Please install a valve on the unapproved discharge pipe,which is located under the emergency overflow riprap area of Pond#1. See explanation in details below. 2. Please submit pictures of the drained pond showing the equalizer pipes installed. File Review Yes No NA NE Is the permit active? ❑ ❑ ❑ Signed copy of the Engineer's certification is in the file? ❑ ❑ ❑ Signed copy of the Operation&Maintenance Agreement is in the file? ® ❑ ❑ Copy of the recorded deed restrictions is in the file? ❑ ❑ ❑ Comment: SW Measures yes No NA NE Are the SW measures constructed as per the approved plans? ❑ ® ❑ ❑ Are the inlets located per the approved plans? ® ❑ ❑ ❑ Are the outlet structures located per the approved plans? ® ❑ ❑ ❑ . Comment: A die test was performed and the results confirmed that the outlet pipe under the emergency overflow - riprap is draining the pond. This is considered short-circuiting the pond. Therefore this pipe needs to be plugged. Since this will change the overall performance of the pond it has been proposed that the pipe be plugged with a gate valve in the closed position and locked. Then if it needs to be opened later for some reason (i.e.-to drain the pond or change the level) it can be done. However, please note that this will require approval by DEQ State Stormwater first. The equalizer pipes could not be located in the field due to murky water. Operation and Maintenance yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? ® ❑ ❑ ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to ❑ ❑ ❑ DWQ upon request? Comment: Pond#1 level was down from the previous inspection even with the rain last night. However, it was still higher than the normal pool. Pond#2 level was down about the same amount. page: 2 Pusey, Steven From: Pusey, Steven Sent: Friday, February 26, 2016 2:06 PM To: 'Edward Coleman' Cc: Kyle Berzina; Abby Stanley; Jaymie McGuire Subject: RE: Georgetowne Depth Plots Okay. I will try to rneet your next week at the pond, For bond 1., I thinly it will be good to check the elevation at the overflow to see if it matches the drawing. If so, then the elevation of the pond bottom could be measured by subtracting your depth readings. if the depth measures 12', then the elevation of the pork bottom would be 22' (overflow elevation) - 2' (depth) = t ' elevation. This would mean that there is 2' of sediment because it's supposed to have an ' bottom elevation. As a general rule, the pond should be mucked out when it has 1' of sediment in it. Or, the older- rule of thumb was to muck it out when it reached 2 gf of the depth, which would be about 2' of sediment, Steve Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven.Qus�y o ncdenr gay 127 Cardinal Drive Ext. Wilmington, NC 28405 mom �Awmlhk Email correspondence to and from this address is,su iect to the North Carolina public records Lair and may be disclosed to third fatties. Beare printing this email,Tease consider year budget and the environment. From: Edward Coleman [mailto:Edward@retentionponds.com] Sent: Friday, February 26, 2016 1:13 PM To: Pusey, Steven <steven.pusey@ncdenr.gov> Cc: Kyle Berzina <kyle@cepco-nc.com>; Abby Stanley<abby@retentionponds.com>; Jaymie McGuire <jaymie@ retention ponds.com> Subject: Re: Georgetowne Depth Plots Steve, 1 The pond does draw down but slowly. I have seen it at normal pool several times. I do not have the elevation of the emergency spillway but I can get that to you next week. I am traveling today and am out at the beginning of next week but I can meet you at the pond mid next week.Thanks and have a good weekend. Edward Sent from my iPhone On Feb 26, 2016, at 11:29 AM, Pusey, Steven <steven, rise a)ricdenr.gov>wrote: I haven't: had time to review the plot depths but I do have a question about the level of water in Pend 1. Why does it have such a high level all the time? It doesn't seem to draw down. Have you observed it in a drawn down state? What is the elevation at the emergency overflow as measured in the field? Steve c5 IG, m tc. Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct st ven.puse a.DLderKAov 127 Cardinal Drive Ext. Wilmington, NC 28405 <irnage001 prig> Email correspondence to and from this address is swbioct to the North Carolina Public r'=if`;cords Law and may be &,.ol(sEa'i';ic)third panties, >. <image007.jpg>Before printing this email, geese consider your gadget and the environment. From: Edward Coleman [mailtw dwan, rete tior onds.corn] Sent:Thursday, February 25, 2016 10:32 AM To: Pusey, Steven<steve�us?y > Cc: Kyle Berzina <k e c.e aco--nc.com �retentionponds >; Abby Stanley<abbb .corn>;Jaymie McGuire < r pie r ter�tic n nds.corn> Subject: Georgetowne Depth Plots Steve, Attached please find the depth plots for the ponds at Georgetowne you requested. I went out to inspect the site yesterday and decided to perform another depth plot so that you would have current numbers. The ponds are designed to have a depth of 7.75 feet at the deepest point in each basin. Pond #1 had an average depth of 12.72 feet less the high water level of+/- 2 feet resulted in an average depth of around 10 feet over the area designed to be the deepest portion of the basin. Pond #2 had an average depth of 9.41 feet less the high water level of+/-2 feet resulted in an average depth of around 7.5 feet over the area designed to be the deepest portion of the basin. 2 Pusey, Steven From: Edward Coleman <Edward@retentionponds.com> Sent: Thursday, February 25, 2016 10:32 AM To: Pusey, Steven Cc: Kyle Berzina; Abby Stanley; Jaymie McGuire Subject: Georgetowne Depth Plots Attachments: Georgetowne Pond #1 - Depth Plot 2-24-16.pdf; Georgetowne Pond #2 Depth Plot- 2-24-16.pdf Steve, Attached please find the depth plots for the ponds at Georgetowne you requested. I went out to inspect the site yesterday and decided to perform another depth plot so that you would have current numbers. The ponds are designed to have a depth of 7.75 feet at the deepest point in each basin. Pond#1 had an average depth of 12.72 feet less the high water level of+/-2 feet resulted in an average depth of around 10 feet over the area designed to be the deepest portion of the basin. Pond #2 had an average depth of 9.41 feet less the high water level of+/-2 feet resulted in an average depth of around 7.5 feet over the area designed to be the deepest portion of the basin. The measurements reveal that Pond #1 is around 2.25 feet deeper than designed at the deepest portion of the basin while Pond #2 is around .25 feet shallower than designed at the deepest portion of the basin but well within the permitted parameters. I hope this is help. Please let me know if you have any questions.Thanks. Edward Coleman Retentiom 10—Vnd 5ervice5 3317 Masonboro Loop Rd- Suite 150 Wilmington,NC 28408 910-313-6830 ext 117 910-313-6870 Fax 910-443-9341 Cell www.retentionponds.com 1 . _... • 's v j+• i r lima 8 s - f • f s Kil��;l'O�rl�� Ia �t • i I • � � 1.1 E i o � t 163 9' f I! I �� "q\, IQ Cn ? rn � l ® t ; m I , ;' ►� I I I rri, - Compliance Inspection Report Permit: SW8950109 Effective: 10/09/15 Expiration: 02/09/23 Project: Georgetown Subdivision Owner: Georgetowne Homeowners Association County: New Hanover Adress: 4200 S College Rd Region: Wilmington City/State0p: Wilmington NC 28412 Contact Person: Cathie Johnston Title: President Phone: 910-392-7201 Directions to Project: College Road,just south of Cape Fear Academy Type of Project: State Stormwater-HD-Detention Pond Drain Areas: 1-(Bamards Creek) (03-06-17)(C;Sw) On-Site Representative(s): Related Permits: Inspection Date: 02/22/2016 Entry Time: 10:OOAM Exit Time: 11:30AM Primary Inspector: Steven G Pusey Phone: Secondary Inspector(s): Reason for Inspection: Follow-up Inspection Type: Transfer Renewal Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant Not Compliant Question Areas: State Stormwater (See attachment summary) page: 1 Permit: SW8950109 owner-Project: Georgetowne Homeowners Association Inspection Date: 0 2/2212 01 6 Inspection Type Transfer Renewal Reason for Visit: Follow-up Inspection Summary: At time of inspection,it was noticed that Pond 1 was full of water up to the emergency overflow elevation,which was the same as during the last inspection. Previously, it was believed that the pond needed to be cleaned out. I met at the site with Kyle Berzina of CEPCO,who stated that Retention Pond Services had completed a survey of the pond. I requested that it be submitted as soon as possible. The survey should show an array of bottom elevations covering the surface area of the pond. From here,it can be compared to the design condition to evaluate the volume provided.We will also need to know the surveyed elevation of the emergency overflow and the orifice pipe(if it can be measured). The approved drawing shows the emergency overflow at 23 feet and the permanent pool at 15.75 feet. The pond should be around 7.5 feet deep or at 8.25 feet bottom elevation. There was a pipe outlet at the bottom of the emergency overflow, not shown on plans,apparently designed to draw down Pond 1. It is believed that it helps draw down some of the ground water infiltrating into the pond. This needs to be verified. NE File Review Yes No NA Is the permit active? M ❑ ❑ ❑ Signed copy of the Engineer's certification is in the file? 0 110 ❑ Signed copy of the Operation&Maintenance Agreement is in the file? M ❑ ❑ ❑ Copy of the recorded deed restrictions is in the file? M ❑ ❑ ❑ Comment: SW Measures Yes No NA NE Are the SW measures constructed as per the approved plans? ❑ M ❑ ❑ Are the inlets located per the approved plans? M ❑ ❑ ❑ Are the outlet structures located per the approved plans? 0 ❑ ❑ ❑ Comment: There is an outlet pipe under the emergency overflow riprap area that is not shown on the plans. Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? 0 110 ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to ❑ ❑ ❑ M DWQ upon request? Comment: Pond#1 was full of water,again up to the emergency overflow elevation. page: 2 Pusey, Steven From: Pusey, Steven Sent: Monday, February 22, 2016 5:04 PM To: 'Edward Coleman'; Kyle Berzina Subject: RE: Georgetown Subdivision permit SW8 950109 The inspection went well. To summarize, I need for you to send me the survey data for the upper pond bottom, which was full up to the overflow elevation. This is necessary to evaluate the pond volume and storage volume of the system. The erosion was under control and all else looked good. Steve Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven.puseyo_ncden r.Aov 127 Cardinal Drive Ext. Wilmington, NC 28405 tne+ }s Mineral r)d)Gf�tlnCf Rt€1ktLT`Ce S u:•YE8®Kpi4TAi{34&€IlY Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Before printing this email,please consider your budget and the environment. From: Edward Coleman [mailto:Edward@retentionponds.com] Sent: Monday, February 22, 2016 2:03 PM To: Kyle Berzina<kyle@cepco-nc.com>; Pusey,Steven <steven.pusey@ncdenr.gov> Subject: RE:Georgetown Subdivision permit SW8 950109 Gentlemen, My sincerest apologies. I was out of town last Thursday and Friday when we confirmed this meeting and when I returned to my office this morning I simply forgot we had scheduled the meeting. Edward Coleman i Retention fond 5ervicee 3317 Masonboro Loop Rd- Suite 150 Wilmington,NC 28408 910-313-6830 ext 117 910-313-6870 Fax 910-443-9341 Cell www.retentionponds.com From: Kyle Berzina [mailto:kyle@cepco-nc.com] Sent: Friday, February 19,2016 10:12 AM To: Pusey,Steven<steven.pusey@ncdenr.gov>; Edward Coleman<Edward@ retention ponds.com> Subject: RE:Georgetown Subdivision permit SW8 950109 Sounds good—see you both at the entrance gate into the area (off of Tollington) Thank you, Kyle J. Berzina,AMS® Director of Operations Email: kyle@cepco-nc.com Main: (910)395-1500/ Fax: (910) 395-6229 P.11A—m ialion\I:nur�.;t•nn•nf 1628 Doctors Circle,Wilmington, North Carolina 28401 Our Office Hours: Monday through Thursday: 8:30 a.m.-5:00 p.m. Friday: 8:30 a.m.—12:30 p.m. Saturday/Sunday: Closed Please visit us at www.cepco-nc.com CONFIDENTIALITY NOTICE:This e-mail message including attachments, if any, is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material.Any unauthorized review, use,disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. If you are the intended recipient but do not wish to receive communications through this medium, please do advise the sender immediately. From: Pusey,Steven [mailto:steven.pusey@ncdenr.gov] Sent: Friday, February 19,2016 8:45 AM To: Edward Coleman<Edward retentionponds.com>; Kyle Berzina<kyle@cepco-nc.com> Subject: RE:Georgetown Subdivision permit SW8 950109 Okay. I'll see you on Monday morning, Feb. 22, at 10 am. 2 Steve stym q. PuAm* Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven.puseyCcD-ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 £ner y,Mineral and fund Resourers FHvl�PNSK+tTAc SVa41TY Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. ` ' Before printing this email,please consider your budget and the environment. From: Edward Coleman [mailto:Edward a@retentionponds.com] Sent:Thursday, February 18, 2016 6:02 PM To: Kyle Berzina<kyle cepco-nc.com> Cc: Pusey,Steven<steven.pusey@ncdenr.gov> Subject: Re:Georgetown Subdivision permit SW8 950109 Works for me.Thanks! Edward Sent from my iPhone On Feb 18, 2016,at 5:57 PM, Kyle Berzina<kvle@cepco-nc.com>wrote: Gentlemen: Monday at 10 a.m. works for me. Thank you, Kyle J. Berzina,AMS® Director of Operations Email: kvle@cepco-nc.com Main: (910) 395-1500/Fax: (910) 395-6229 <image001.jpg> 1628 Doctors Circle,Wilmington, North Carolina 28401 Our Office Hours: Monday through Thursday: 8:30 a.m. -5:00 p.m. Friday: 8:30 a.m.—12:30 p.m. Saturday/Sunday: Closed 3 Please visit us at www.cepco-nc.com CONFIDENTIALITY NOTICE:This e-mail message including attachments, if any,is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material. Any unauthorized review, use,disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. If you are the intended recipient but do not wish to receive communications through this medium, please do advise the sender immediately. From: Pusey,Steven [mailto•steven.pusey@ncdenr.gov] Sent:Thursday, February 18, 2016 4:43 PM To:Edward Coleman<Edward@ retention ponds.com>; Kyle Berzina<kyle cepco-nc.com> Subject: RE:Georgetown Subdivision permit SW8 950109 1 can probably meet Monday morning at say 10 am out there. Is that okay with everyone? Steve Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct Steven.puseyamcden r.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 <image002.png> Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. <image003.jpg>Before printing this email,please consider your budget and the environment. From: Edward Coleman [mailto•Edward(@retentionponds.com] Sent:Thursday, February 18, 2016 2:54 PM To: Kyle Berzina<kyle cepco-nc.com> Cc: Pusey,Steven<steven.pusey@ncdenr.gov> Subject: RE:Georgetown Subdivision permit SW8 950109 Crazy day for me. I just saw this. I can't meet today but can meet in the morning before 11:00 or next Monday morning before 11:00. My next availability is next Thursday the 25 any time before 3:00. Thanks. Edward Coleman <image004.j pg> 3317 Masonboro Loop Rd- Suite 150 Wilmington,NC 28408 4 910-313-6830 ext 117 91.0-313-6870 Fax 910-443-9341 Cell www.retentionponds.com From: Kyle Berzina [mailto:kyIee cepco-nc.com] Sent:Thursday, February 18, 2016 9:27 AM To: Edward Coleman<Edward@retentionponds.com> Cc:steven.pusey@ncdenr.gov Subject: FW:Georgetown Subdivision permit SW8 950109 Steven, I am copying Edward Coleman with RPS,who is performing the restoration work. I would like for Edward to join us... Hopefully between the three of us,we can find a date/time that will work. Edward,can you meet this afternoon? Thank you, Kyle J. Berzina,AMS® Director of Operations Email: kyle@cepco-nc.com Main: (910) 395-1500/Fax: (910) 395-6229 <image001.jpg> 1628 Doctors Circle,Wilmington, North Carolina 28401 Our Office Hours: Monday through Thursday: 8:30 a.m. -5:00 p.m. Friday: 8:30 a.m.—12:30 p.m. Saturday/Sunday: Closed Please visit us at www.cepco-nc.com CONFIDENTIALITY NOTICE:This e-mail message including attachments, if any, is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material.Any unauthorized review, use,disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. If you are the intended recipient but do not wish to receive communications through this medium, please do advise the sender immediately. From: Pusey,Steven [mailto:steven.pusey@ncdenr.gov] Sent:Thursday, February 18, 2016 8:01 AM To: Kyle Berzina<kvle@cepco-nc.com> Subject: RE:Georgetown Subdivision permit SW8 950109 I'm going to be down that way this afternoon. Would you like to meet then? Steve 5 vtC rm-xL 0. PU_4C* Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven.pusey ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 <image002.png> Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. <image003.jpg>Before printing this email,please consider your budget and the environment. From: Kyle Berzina [mailto:kyle@cepco-nc.com] Sent: Monday, February 15, 2016 10:51 AM To: Pusey,Steven<steven.pusev@ncdenr.gov> Subject: FW:Georgetown Subdivision permit 5W8 950109 Steven, Good morning... RPS is still working on the project...they anticipate completing this week. I would like for RPS(Edward Coleman)to join us when you and I walk the area. How does next week look on your schedule? Thank you, Kyle J. Berzina,AMS® Director of Operations Email: kyle@cepco-nc.com Main: (910)395-1500/ Fax: (910) 395-6229 <image001.jpg> 1628 Doctors Circle,Wilmington, North Carolina 28401 Our Office Hours: Monday through Thursday: 8:30 a.m. -5:00 p.m. Friday: 8:30 a.m.—12:30 p.m. Saturday/Sunday: Closed Please visit us at www.cepco-nc.com CONFIDENTIALITY NOTICE:This e-mail message including attachments, if any, is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material.Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. If you are the intended recipient but do not wish to receive communications through this medium, please do advise the sender immediately. 6 From: Edward Coleman [m ailto:Edward@ retentionponds.com] Sent:Saturday, February 13, 2016 8:44 AM To: Kyle Berzina<kyle@cepco-nc.com> Subject:Georgetown Subdivision permit SW8 950109 1 would schedule the inspection after we complete the scope of work. If we did not finish yesterday we should be done by Tuesday at the latest. I will be glad to join y'all for the inspection if you would like. Edward Coleman <irnage004 Jpg> 3317 Masonboro Loop Rd- Suite 150 Wilmington,NC 28408 910-313-6830 ext 117 910-313-6870 Fax 910-443-9341 Cell www.retentionponds.com Begin forwarded message: From:"Pusey,Steven"<steven.pusey@ncdenr.gov> Date: February 12, 2016 at 2:58:17 PM EST To: Kyle Berzina<kvle@cepco-nc.com> Cc:Virginia Wright<vwright@cepco-nc.com> Subject: RE:Georgetown Subdivision permit SW8 950109 Mr. Berzina, I am going to be in the area on Feb. 18 and was wondering if that would be a good time to meet with you and inspect the Georgetown Subdivision pond. Please advise. Thanks, Steve erfO-,,-.i. 07. /PUA.-V Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven.pusey a-ncdenr.gov 127 Cardinal Drive Ext. Wilmington, NC 28405 <image002.png> Email correspondence to and from this address is subject to the 7 North Carolina Public Records Law and may be disclosed to third parties. <i mage003.jpg>Before printing this email,please consider your budget and the environment. From: Kyle Berzina [mailto:kvle@cepco-nc.com] Sent:Thursday,January 21, 2016 10:53 AM To: Pusey,Steven<steven.pusey@ncdenr.gov> Cc:Virginia Wright<vwright@cepco-nc.com> Subject: RE:Georgetown Subdivision permit SW8 950109 Steve, Good morning... the Board is reviewing the$16k restoration bid tonight as part of their meeting agenda. I am hopeful it will be approved and RPS can proceed with the identified work. Thank you, Kyle J. Berzina,AMS® Director of Operations Email: kyle@cepco-nc.com Main: (910)395-1500/ Fax: (910) 395-6229 <image001.jpg> 1628 Doctors Circle,Wilmington, North Carolina 28401 Our Office Hours: Monday through Thursday: 8:30 a.m. -5:00 p.m. Friday: 8:30 a.m.—12:30 p.m. Saturday/Sunday: Closed Please visit us at www.cepco-nc.com CONFIDENTIALITY NOTICE:This e-mail message including attachments, if any, is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material.Any unauthorized review, use,disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. If you are the intended recipient but do not wish to receive communications through this medium, please do advise the sender immediately. From: Pusey,Steven [mailto:steven.pusev@ncdenr.gov] Sent:Tuesday,January 19,201610:31 AM To: Kyle Berzina<kvle@cepco-nc.com> Subject:Georgetown Subdivision permit SW8 950109 Kyle, Have the ponds in the subject stormwater system been maintained in accordance with the requirements of our last inspection of October 7, 2015? Steve 8 Environmental Engineer Division of Energy, Mineral and Land Resources—State Stormwater Program Department of Environmental Quality 910 796 7215 office 910 796 7334 direct steven.pusey ncdenr.cgov 127 Cardinal Drive Ext. Wilmington, NC 28405 <irnage002.png> Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. <image003.jpg>Before printing this email,please consider your budget and the environment. 9 STATE OF NORTH CAROLINA Department of Environmental and Natural Resources 127 Cardinal Drive Extension Wilmington,North Carolina 28405 (910)796-7215 FILE ACCESS EECORD ze SECTION TIME/DATE j NAME REPRESENTING on Re ionat Office is dedicated to making public records in Guidelines for Access: The staff of Wilmington g our custody readily available to the public for review an -to-day program We also have the responsibility to the d copying, also obligations. Please read public to safeguard these recordss and to carry out our day gr carefully the fonowmg guidelines signing the form. f. Due to the large public demand for file access,we request that you call at least a day in advance to schedule an appointment to review the files. A ointnnerAts vrgll be scheduled between 9�00am and 3.00 m. to the extent that txnne and staif'ie,wing time ends at 4:45pm, Ans�n is available. a ointzment ma vxcer the files . The number of files that you 2. You must specify files you want to facility name. may review at one time will b limited to f� ff and if 3. You may make copies of a file when the copier zs not in use by the ade b heck money order o�ash at the Cost per copy is$.05 cents.l'a meat ma be rerentioA desk. Go yes tatalin �5.40 or more cam be invoiced for our convenreiace. 4. FILES I��JS� BE KEPT IN ORDER YOU�'O�71��THEM. Filesnmof th se fileay riot be s is a en from the office. To remove,alter,deface,mutilate,or destroy mat misdemeanor for which you can be fined up to$500.00. NO briefcases large totes,etcl axe- ermitted in the file review area. 5. In accordance with General Statue 25-3-512,a$25.00 processing fee will be charged and collected-for checks on which payment has been refused, COUNTY FACILITY NAME 4. f G'dl�14-r ✓ Time In Time Out Signature and Name of Firm/Business Date Please attach a business card to this form � � INVOICE COPIES MADE _ S:AdmznBe access sTAj OF NORTH C ROLINA Department of Environmental and Natural Resources 127 Cardinal Drive Extension Wi9rniugton,North Carolina 28405 (910)796-7215 FILE.A.CCES MCD SECTION TIME/DATE NAME REPRESENTING in Guidelines for Access: The staff of"Wilmington Regional Office is dedicated to making public records our custody readily available to the public for review and copying. We also have the responsibility to the public to safeguard these records and to carry out our day to-day program obligations. Please read carefully the following guidelines signing the form. qust that you call at least aay in 1. Due to the large public demand for file access,we rOe files.e flint e s�h be chieduled advance to schedule an appointment to review tk between 9=00am an 3:00p— Viewie extent thatng time ends atiane a nd staff su 9s avajabl . a oimtmeut ma view tlac des to th 2. You must specify files you want to reeview d to fiver f aczli — The number of fits that you may review at one time will be lit its- 3. You may make copies of a file when the copier is not in use by made b he the staff and if time Perm the Cost per copy is$.OS cents.Pa mcmt Ma �° recenis 01D desk. Co is tatatsn PD.U0 0r more can be inv€►iced for our conveniezace. ay not be en M Files 4. F_ILFS MU .BE KEPT�defaceORDER tilate,o YOU r destroy mUND material in onemofth se files is a om the office. To remove,alter, , misdemeanor for which you can be fined up to$500.00. N briefcases lame totes,etc.are ermitted in the file review area. 3. In accordance with General Statue 25-3-512,a$25.00 processing fee will be charged and collected-for checks on which payment has been refus C l?ACZLI TY NAME • � �,�j `off� Pt'`�-) r�:�' 4. TV -_--- - Ir�� Time Out Signature an.dName ofliirmlBusiness Date Time In Please attach a business card to this foPA� T07�E COPIES MADE—. &Adnain.file access i STATE OF NORTH CAROL I NA Department of Environmental and Natural Resources 127 Cardinal Drive Extension Wilmington,North Carolina 28405 (910)796-7215 FILE ACCESS RECORD SECTION TIME/DATE �'� NAMEfi REPRESENTING - d Guidelines for Access: The staff of Wilmington Regional Office is dedicated to making public records in our custody readily available to the public for review and copying. We also have the responsibility to the arry out our day-to-day program obligations. Please read public to safeguard these records and to c carefully the following guidelines signing the form: r. Due to the Iarge public demand for file access,we request that you call at least a day in advance to schedule an appointment to review the files. Aiointments eeill be scheduled between 9�OOam and 3:®Opm. Viewing time ends at 4:45pm. �nyone arriving without as a ointment ma view the files to the extent that tinge and staff su ervision is available. 2. You must specify files you want to review by facility nan�ie• The number of files that You may review at one time will be limited to five. 3. You may make copies of a file when the copier is not in use by the staff and if time permits. Cost per copy is$.05 cents.Pavment may be made by check money order,-or cash at the reception desk. Copies totaling$5 00 or more can be invoiced for your convenience. 4. bILFS MUST.BE KEPT IN ORDER YOU FUND THEM.'Files may not be taken from the office. To remove,alter,deface,mutilate,or destroy material in one ofthese files is a misdemeanor for which you can be fined up to$500,00. No briefcases large totes etc.are pemvtted in the file review area. 5. In accordance with General Statue 25-3-512,a$25.00 processing fee will be charged and eollected.for checks on which payment has been refused. FACILITY NAME COUNTY � f r%f' �H�� 3. 4. P f / Signature and Name of Firm/Business Date Time In Time Out Please attach a business card to this form IVOICE COPIES MADE PAID S:AdminRo access Compliance Inspection Report Permit: SW8950109 Effective: 02/09/01 Expiration: 02/09/15 Project: Georgetowne Subdivision Owner: Georgetowne Homeowners Association County: New Hanover Adress: 4200 S College Rd Region: Wilmington City/State/Zip: Wilmington NC 28412 Contact Person: Cathie Johnston Title: President Phone: 910-392-7201 Directions to Project: College Road,just south of Cape Fear Academy Type of Project: State Stormwater-HD-Detention Pond Drain Areas: On-Site Representative(s): Related Permits: Inspection Date: 10/07/2015 Entry Time: 01:OOPM Exit Time: 02:OOPM Primary Inspector: Steven G Pusey Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Transfer Renewal Permit Inspection Type: State Stormwater Facility Status: ❑ Compliant ® Not Compliant Question Areas: ® State Stormwater (See attachment summary) page: 1 Permit: SW8950109 Owner-Project: Georgetowne Homeowners Association Inspection Date: 10/07/2015 Inspection Type Transfer Renewal Reason for Visit: Routine Inspection Summary: Although we have had a lot of rain recently, Pond#2 was down below the 10-year storm elevation which shows that it is drawing down properly. Pond#1 was full of water up to the emergency overflow elevation. This is a sign that there may not be enough volume in the pond. Therefore,the bottom elevations of the pond should be surveyed to determine the sediment level. The pond should be mucked out if necessary in accordance with the Operation &Maintenance Agreement. File Review Yes No NA NE Is the permit active? ■ ❑ ❑ ❑ Signed copy of the Engineer's certification is in the file? ❑ ❑ ❑ Signed copy of the Operation&Maintenance Agreement is in the file? ❑ ❑ ❑ Copy of the recorded deed restrictions is in the file? ■ ❑ ❑ ❑ Comment: SW Measures Yes No NA NE Are the SW measures constructed as per the approved plans? ❑ ❑ ❑ Are the inlets located per the approved plans? ❑ ❑ ❑ Are the outlet structures located per the approved plans? ■ ❑ ❑ ❑ Comment.- Operation and Maintenance Yes No NA NE Are the SW measures being maintained and operated as per the permit requirements? ® ❑ ❑ ❑ Are the SW BMP inspection and maintenance records complete and available for review or provided to ❑ ❑ ❑ N DWQ upon request? Comment: Pond#1 was full of water up to the emergency overflow elevation This is a sign that there may not be enough volume in the pond. Therefore the bottom elevations of the pond should be surveyed to determine the sediment level. The pond should be mucked out if necessary in accordance with the Operation& Maintenance Agreement page: 2 B STATE OF NORTH CAR®LINA k / Leent of Environment and Natural Resources AIR® Regional Officeq1 /0 F Et IL ACCESS REC®R N DATE/TIME G NAME REPRESENTING 297- 7z 1' - �- Guidelines for Access: The staff of the Regional Offiep is dedicated to making public records in our custody readily available to the public for review and copying. We also have the responsibility to the public to safeguard these records and to carry out our day-to-day program obligations. Please read carefully the following before signing the form. 1. Due to the large public demand for file access, we request that you call at least a day in advance to schedule an appointment for file review so you can be accommodated. Appointments are scheduled between 9.00 a.m. and 3�00 p.m. Viewing time ends at 4 45 p.m. Anyone arriving without an appointment may view the files to the extent that time and staff supervision are available. 2. You.must specify files you want to review by facility name or incident number, as appropriate. The number of files that you may review at one appointment will be limited to five. 3 You may make copies of a file when the copier is not in use by the staff and if time permits. There is no charge for 25 or less copies. cost per copy after the initial 25 is 2,5 per copy. Payment is to be made by check, money order, or cash in the administrative offices. 4- Files must be kept in the order you received them. Files may not be taken from the office. No briefcases, large totes, etc. are permitted in the file review area To remove, alter, deface, mutilate, or destroy material in public files is a misdemeanor for which you can be fined up to $500.00. 5. In accordance with GS 25-3-512, a $25.00 processing fee will be charged and collected for checks on which payment has been refused. 6. The customer must present a photo I®, sign-in, and receive a visitor sticker prior to reviewing files. FACILITY NAME COUNTY �-5-`� l4; 2. 3. 4. 5. Signature/Name of Firm or Business ®ate Time In. Time Out (Please attach business card to form if available) # Copes: Amt. Pd: L� Z 153 115 232 1 also wish to receive the US Postal Service following services(for an Receipt for Certified Mail ?can return this extra fee): ;e does not 1.El Addressee's Address No Insurance Coverage Provided. > Do not use for International Mail See reverse le number. 2•❑ Restricted Delivery a) Sent toy d the date Consult postmaster for fee. a ® Street&Num r 4a.Article Number 0 d 0?_Z vrt' hisv lleAe z I153 116 232. it Post opice,State, Z Code t z 4o 4b.Service Type �,/ 7 �- ElC Registered Certified °1 Postage $ ❑ Express Mail ❑ Insured Certified Fee ❑ Return Receipt for Merchandise ❑ COD V 7. Date of Delive o Special Delivery Fee 0 8.Addressee's Address(Only if requested T Restricted Delivery Fee � Y p � ,n and fee is paid) m Return Receipt Showing to 1 F Whom&Date Delivered a Return Receipt Showing to Whom, Q Date,&Addressee's Q - - - 12595-98-8-0229 Domestic Return Receipt 0 TOTAL Postage&Fees2/1 cl Postmark or Date r 16 E ` 0 a Wilmingtor, NJ 28411 UPS "a STATE o a+v State of North Carolina Department of Environment, Health, and Natural Resources Wilmington Regional Office James B. Hunt, Jr. Division of Water Quality Wayne McDevitt Governor Water Quality Section Secretary August 8, 1997 Ms. Sandra Dail, Interim President Georgetown HOA c/o Landmark Organization 5022 Wrightsville Avenue Wilmington, NC 28403 Subject: COMPLIANCE INSPECTION Georgetown Subdivision Stormwater Project No. SW8 950109 New Hanover County Dear Ms. Dail: Please find attached a copy of the completed form entitled "Stormwater Compliance Inspection Report". The report summarizes the findings of a recent inspection of the project's stormwater controls conducted on August 7, 1997 to determine compliance with Stormwater Permit Number SW8 950109 issued to you on November 27, 1996. A summary of the findings and comments are noted under Section 6 of the report. Please inform this Office in writing before September 8, 1997 of the specific actions that will be undertaken and the time frame required to correct the deficiencies. Failure to provide the requested information, when required, may initiate enforcement action. If you have any questions please contact me at the Wilmington Regional Office, telephone number (910) 395-3900. Sincerely, Linda Lewis Environmental Engineer RSS/arl: S:\WQS\STORMWAT\INSPECT\950109.AUG cc: Mark Ashness, P.E. Central Files Linda Lewis 127 Cardinal Drive Extension,Wilmington,N.C.28405-3845•Telephone 910-395-3900 0 Fax 910-350-2004 An Equal Opportunity Affirmative Action Employer STORMWATER COMPLIANCE INSPECTION REPORT 1. Project Name: Georgetown Subdivision Project Number: SW8.950109 Control Measure: a Detention Pond Water Body: Barnards Creek Classification: C Sw Directions to site, address: South College Road, between 17th Street and Monkey Junction, Wilmington 2. Inspection Date: August 7, 1997 Weather Conditions: Warm, sunny 3. Comparison of Approved plans vs. As-Built: Compared well. 4. Maintenance Problems: a. Pond could not be accessed for inspection. No clear routes to pond due to construction. b. The phasing pattern approved as temporary routing to the first pond seems to have been expanded without benefit of an approved plan. It appears that both the first and second roads to the right, and the third road to the left are in, while only 100 -150 feet of each were approved in the first phase. Per Section I, Item 2, Phase II of the pond must be complete prior to construction beyond the temporary phase line approved. 5. PE Certification Received? 9/19/96 (Phase I only) Deed Restrictions Received? 10/21/96 6. Comments: a. Access to the pond must be available at all times. Please indicate in your reponse the designated route available for access. b. Submit the Engineer's Certification for Phase II of the pond. If Phase II has not been constructed, you are in violation of your permit. Inspector: Linda LewisAl_� Water Quality/Wilmington Regional Office/(910) 395-3900 RSS/arl: S:\WQS\STORMWAT\INSPECT\950109.AUG