Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
310889_Application Attachment - Digester Drawings_20241014
DU LIN COUNTY, NORTH CAROLINA ADDRESS DONNA SMITH - SR 1704, 579 KITTY NOECKER RD, PINK HILL, NC LEGEND: CIVIL ENGINEER — — = ROESLEIN &ASSOCIATES, Rw RAINWATER o. 9200 WATSON ROAD SUITE 200 —GAS! = GAS LINE G ST. LO U I S, MO 63126 — LS = LIFT STATION (314) 729-0055 _ T_ = UNDERGROUND TELEPHONE OHEOVERHEAD ELECTRICAL *I DONNA SMITH ST — = STORM DRAIN ELECTRICAL ENGINEER wTL- = WATER TRANSFER LINE Z ROESLEIN & ASSOCIATES, GO = GRAVITY OVERFLOW � 9200 WATSON ROAD SUITE 200 m ST. LO U I S, MO 63126 � — = PROPERTY LINE (314) 729-0055 = SET BACK LIMITATIONS Y U w 1.500 = OCCUPIED RESIDENCES SET BACK N z BAN s� 2.500 = CHURCH & SCHOOL SET BACK TRUE NORTH SHEET INDEX — — — = DIGESTER OPTIONS COUNTY MAP ,5 RA270-00-27050-1 - COVER & SHEET INDEX ® = EXISTING POWER POLE RA270-00-27050-2 - AREA 1000 DONNA & THOMAS SMITH = CONCRETE BARRIER SITE LAYOUT = EXISTING SEWER MODIFICATION RA270-00-27050-3 -AREA 1000 NEW DIGESTER LAYOUT DATA FROM FISH & WILDLIFE NATIONAL WETLANDS SHEET INDEX 100' WET WELL SETBACK VICINITY MAP RA270-00-27050-1 - COVER & SHEET INDEX N RA270-00-27050-2 - NEW DIGESTER GRADING RA270-00-27050-3 - AREA 1000 DONNA & THOMAS SMITH SITE LAYOUT TRUE NORTH RA270-00-27050-4 - AREA 1000 NEW DIGESTER LAYOUT LEGEND: RA270-00-27050-5 - AREA 1000 HYDRAULIC PROFILE = DUPLIN COUNTY RA270-00-27050-6 - AREA 1000 EROSION CONTROL Detail Drawing Control Index Sys. Sys. Description Drawing DWG Description RA-STD-251-2 Typical Lagoon Operating Levels General Drawings RA-STD-253-2 Anchor Trench Installation RA-STD-270 Liner Penetration Installation RA-STD-265-2 Sewer Cleanout S-1 Digester Influent RA-STD-269 Forced Sewer RA-STD-280-2 Lift Station Pump Piping RA-STD-263-3 Floating Pump Discharge S-2 Digester Effluent RA-STD-275-2 Transfer Water Discharge RA-STD-295 ART System Connection S-3 Wet Well RA-STD-262-3 Wet Well Installation RA-STD-274-2 Wet Well Level Indicator S-4 Cover/Rain Water RA-STD-256-2 Rainwater Removal Suction Pipe RA-STD-271-3 Rainwater Removal Pump S-5 Mixing RA-STD-289 Typical Lagoon Mixing System S-6 Power Flush RA-STD-266 Power Flush RA-STD-282 Wet Well Power Flush S-7 Sludge Removal RA-STD-264-2 Irrigation Suction SCALE SIZE AS SHOWN E MILLIMETERS: S-8 Digester Vent RA-STD-255-2 Lagoon Vent Ports O���N�..�;4R // C 22SEP23 ISSUED FOR GROWERS MEETING LMB LMB ZL MK x =±0.5 MONARCH BIOENERGY < S �� B 05SEP23 ISSUED FOR GROWERS MEETING ZTS ZTS ZL MK DIMENSION TOLERANCE xx =±0.10 RA-STD-261-1 BIO as Draw -Off ���O�FE / /� A 11AUG23 ISSUED FOR GROWERS MEETING ZTS ZTS ZL MK (UNLESS OTHERWISE xxx=±0.010 z Q -� SPECIFIED) ANGLES =±0.5° PINK HILL NC g = REV DATE REVISION DESCRIPTION BY DRWN CHK'D APP'D RO E V S-9 GCS Interface RA-STD-267 Off -Spec Connection _ s L : # BY BY BY FRACTIONS: INCHES: AREA OOO : �56059 �n THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION MACHINED PARTS -±1/64 RA -STD- 288 Condensate Return THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC AND IS PROTECTED UNDER STATE X =±.020 HOLE LOCATIONS ON AND FEDERAL LAW INCLUDING 1S USC SECTION 1836 AND 17 USC SECTION 101 et se . ROESLEIN &ASSOCIATES INC. AND ROESLEIN ---- q =±1/32 XX =±.010 ALTERNATIVE ENERGY, LLC RESERVES ALL PATENT, COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL WELDED ASSEMBLIES DONNA SMITH �'!� �/�• �� DESIGN, MANUFACTURING, REPRODUCTION, USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY .XXX =±.005 ENGINEERS • MANUFAC (j .. �� LINEAR DIMENSIONS ON XXXX=±.0002 4 t,� ` GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE DUPLICATED OR DISCLOSED IN WHOLE OR IN PART WITHOUT THE EXPRESS =+ '�I / ���• .N•••� v` WRITTEN PERMISSION OF ROESLEIN &ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC. ANY USE OF THE INFORMATION STRUCTURAL WELDMENTS -1/16 ANGLES =±.05° CONTAINED IN THIS STRICTDOCUMENT LYY PROHIBITOTHER THAN BY THE ED. UPON HE REQUEST OF ROEDSLRECIPIENT ASSOCIATES, NC EXPRESS AND ROESLEIN ALFOR ERNATIVIT HAS BEEN E ENERGY, LLC ANGLES =±1 COVER &SHEET INDEX DWG . RA2 70 0 0 2 THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIES THEREOF IN ITS HAIRY STEWART 8/6/2024 3:49:11 PM C:\VAULT\PROJECTS\MONARCH BIO ENERGY\REGISTER NC\CADD\01 RA270\ORTHOS\DWGS\00 GENERAL ARRANGEMENTS\RA270-00-27050.DWG POSSESSION. @2023 ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC DO NOT SCALE PRINT NO. GENERAL NOTES: 1. THE QUANTITIES SHOWN ON THIS PLAN ARE BASED ON ENGINEER'S CALCULATIONS REQUIRED TO ACHIEVE THE DESIRED GRADES. 2. VERIFY LOCATION OF ALL UTILITIES (BOTH ABOVE AND BELOW GROUND) PRIOR TO ANY EXCAVATION. CALL 811 PRIOR TO ANY EXCAVATION ACTIVITIES. 3. EROSION PROTECTION SHALL BE INSTALLED AT INLET LOCATIONS. 4. TOPSOIL STRIPPED FROM THE LAGOON SITE SHALL BE STOCKPILED ON -SITE FOR COVERING THE OUTSIDE OF THE BERMS. 5. EMBANKMENT MATERIALS SHALL BE FREE OF SOD, ROOTS, AND OTHER OBJECTIONALBLE MATERIALS. 6. ALL ELEVATIONS SHALL BE AT GRADE OR PLUS 0.1' OF DESIGN GRADE. 7. BERM FILL FOR THE PROPOSED LAGOON DIGESTER TO BE PLACED IN 6" LIFTS TO 95% OF STANDARD PROCTOR AT -1 % TO +3% OF OPTIMUM MOISTURE. 8. EACH 6" LIFT SHALL BE TESTED FOR MOISTURE/DENSITY BY A QUALIFIED GEOTECHNICAL LABORATORY APPROVED BY ENGINEER. A FAILING TEST REQUIRES REWORK OF AREA TO MEET SPECIFICATION. 9. THE INTERFACE SURFACE OF SUCCESSIVE LAYERS IS TO BE DISKED OR SCARIFIED PRIOR TO PLACEMENT OF SUBSEQUENT LAYERS OF CLAY. 10. ALL INSIDE AND OUTSIDE CUTS/FILLS ARE 3:1 UNLESS OTHERWISE NOTED. 11. NO OFF -SITE MATERIAL MAY BE IMPORTED FOR LAGOON LINING UNLESS APPROVED BY THE ENGINEER. 12. LAGOON TO BE LINED WITH 60-MIL THICK HDPE SYNTHETIC LINER. THE INSIDE WALLS OF THE LAGOON SHALL BE SMOOTH ROLLED PRIOR TO LINER INSTALLATION. 1[d♦�:A]�II�7��3�]»:ZK�7►6��:Z�L��[�7�I9�IH�i1N7:7:IJi/•1�69:IIiC�I��E,Y�1:7��1xy��9_1:�'L.9��]�x.97�7:��]:L11�/_[el■ Cut/Fill Summary Name Cut Factor Fill Factor 2d Area Cut Fill NORTHWEST PROPERTIES rl \ Iz n / /- _�_ tip' < / � Ix ro < � 6 f 1` 9 _ ----_ — —__ II / �\I1 l�\�/ � �/(I/I► \/�(I/�j/// J j � I \ I II I I I t I 1 I // v 1� I I \ 95 /I / I � I fl(II)I 98Il .0/ 0 96 TOP OF BERM I � DRAINAGE SWALE 97/ \ /— ( I\ 1 IICSILT FENCE I/ F_ f ��II 1r ((`l /l� L / (/ c \\ 1 1 I (rl I I I II I l fl lr1 /ll IhlI// 90✓ f / \ r\\ I I 1 \ III / I I I I _I I(( II I I t (1 ► Net � I IIII I I/ S I III 1 I I I I I I I I I I I` 1 � 1 � I �I ► Ir / / I I I III IIIII I/ 1► I I^ I( I I I U I ( I I I I I I I I I II 1 \I o, I EX LAGOON / I I III III 11 I/ I 27 I 1 `� l 11 �j ((►� Ilj�\II tI II � \ I I I 00 I III I I I I 1 11'2 �I I j I I I I �► / I I I I I I i l( l �� r � I I I /► I 1 1 l l (l I II 1 I I` � II / I I I J I 1 1 1 /I l If I I I I / I I I I I III /► I Ill I l ,-_ J II I 11 l 11 / I I IIII I III ;�) I I I \ l I MI I \ II (s I\ 1 I\I\ \\\�� _I ----------------- IlI(/If I L �! 1 I I ) j I \ \ �---_�— QTY 27050 DONNA & THOMAS SMITH 1.000 1.150 68757.30 Sq. Ft. 5610.65 Cu. Yd. 5318.15 Cu. Yd. 292.49 Cu. Yd.<Cut> Totals 68757.30 Sq. Ft. 5610.65 Cu. Yd. 5318.15 Cu. Yd. 292.49 Cu. Yd.<Cut> 1 00 I 1~ (00 � 86.00 I�✓% FLOOR i C C rn o I N NEW _ DIGESTER ' N I N rn N M M I0') z� / 0) 130' \ M rn 00 ` — — — — — I I \ I \\ _ J--_ � 0 1 l 1 _ _ __ _ f v� EX BARN II \ 1 FF:111.0 II � PIT:110.0 II I 14 A 1 lr EX BARN FF:110.5 �/I 1I / PIT:109.51 I J D L' J \ I` i AMILTON 9/26/2024 8:19:47 AM P:\200599\06-DRAWINGS\CIVIL\AlK\REGISTER-CLUSTER 2\AFO PERMIT DRAWINGS\27050 DONNA SMITH AFO PERMIT.DWG + PROPERTY OWNER PROPERTY OWNER NOBLES, WADE S AWFORD, PHILLIP H III & WIFE CRAWFORD, LYNN G - PROPERTY OWNER - PROPERTY OWNER BALL, MICHAEL W. & WIFE MARY JEAN BALL T=# DECORPO, DENNIS G. R # Y ' PROPERTY OWNER 1.500 1 5nn _ • SMITH, THOMAS „" .� - � PROPERTY OWNER EARL &WIFE SMITH, ', � 150° � PROPERTY OWNER CANNON, ABBY I DONNA JEAN 1.500 1.500 SMITH HAROLD J, JR &SMITH \ A 15p0 DSO o PROPERTY OWNER DEBORAH Q, TRUSTEES rso < < i, PROPERTY OWNER o 5o KORNEGAY a ° PROPERTY OWNER �. , \ SMITH, THOMAS EARL & - CONNIE M. Q TAYLOR, KELLY DENISE �s -� � 's0 \WIFE SMITH, DONNAS 1.500 o o ' 1.500 O VA46 % I 7.500 '` QJ \ �# �00 1.500 1.500 ��� 1.500 1.500 • 150p 1 SO 00 1 5 S00 s°° 7 S . + 00 dl � \ s 1.�I # r J \ \49 , 0 500 15L'� 1 SO �� oo o Q�'. \ PROPERTY OWNER Qv a j" 'so0 BRITT FARMING COMPANY, LLC p PROPERTY OWNER TRI-COUNTY ELECTRIC MEMBERSHIP CORPORATION PROPERTY OWNER so i i PROPERTY OWNER J Q� \ GRADY, DOROTHY H. ° °° WILSON, TRACY SMITH � PROPERTY OWNER OUTLAW, TRACY L. o Q PROPERTY OWNER CD.� / 1 SMITH, THOMAS EARL a CD o 0 0 f _ o PROPERTY OWNER a p4 ` SANDERSON, If PROPERTY �, \ o �, \ YVONNE CAROL OWNER a ,o, ',�F 7-1tv o A •r a SMITH, THOMAS EARL Q � * -�'� ��p� PROPERTY OWNER SMITH, THOMAS EARL ocl 40 o J� C / o \ o i PL a PROPERTY o 0 OWNER a i o o PROPERTY OWNER o PC 1�,t SMITH, s o°o o o ho hoo - ram' A� THOMAS EARL -o on P4 o �' PROPERTY OWNER MILLER, VIRGINIA D`, PROPERTY \ PROPERTY OWNER `so < o 0o SMITH, HAROLD J, JR &SMITH, OWNER SMITH, THOMAS DEBORAH TRUSTEES L Q, A� SMITH, THOMAS \ 's EARL &WIFE SMITH, > o 00 y o v + r EARL ° v DONNA JEAN N`? N`� o ^o 4 1 _ 50 \ r PROPERTY WAIVER 's o / ,f � � *` - • OBTAINED ° o p pt " ° s00 \ 15 \ O po Nlo 00 5 h / p` # 1.500 1.5p0 1.5 0 ..__-r/ - O° f 50C P4 ` pt 1.500 1 00 — 1' �� ' / 000 I �� \ � 0 - Sq ' • S O P4 LNy � r t #, 150 <o00 p * W 0—\15 �50 0 I -. 50 1.500 588 1.5 100' WELL SETBACK - . ; G - 11 5 * 4 ' M W 00 1. - 1 00'WELL SETBACK p4 PROPERTY OWNER - p STROUD, JIMMY W. � o - - i STROUD, JO ANN PL SET BACK LIMITATIONS PROPERTY OWNER * _ PROPERTY WAIVER �� _00 SMITH, ANTHONY C. OBTAINED & SMITH SONYA B. * PROPERTY OWNER ' SMITH, THOMAS - EARL & WIFE SMITH, # DONNA S. ' PROPERTY WAIVER OBTAINED PROPERTY OWNER `A RHODES, G. FREDERICK PROPERTY LINE - L d P PROPERTY OWNER HENSLEY, NANCY TURNERk IL PROPERTY OWNER RHODES, G. FREDERICK } 'f PROPERTY OWNER HILL, HOWARD ALLEN wo do F ' J a - � 46 PROPERTY OWNER PL PL PL P PL _ PROPERTY OWNER RHODES, SHANE ROGER SMITH, SHELBY SMITH . CAP Qv . / % a # # a r J a TRUE NORTH %w%III fill/ 0 �S L 56059� Iftli"i 1111111 LBAGGETT4317 9/22/2024 10:08:23 PM C:\VAULT\PROJECTS\MONARCH B10 ENERGY\REGISTER NC\CADD\01 RA270\ORTHOS\DWGS\00 GENERAL ARRANGEMENTS\RA270-00-27050.DWG FARM 1 0 PRODUCTION INFORMATION CITY 98.00 AVG AN N UAL AN I MAL POPU LATI ON 3520 0 ESTIMATED RNG I NJ DTH/YR 4396 - di 0, AN I MAL TYPE GF BARN OPERATION TYPE Pit Recharge . o0 �° SYSTEMS p�pp SYSTEM OPTION SELECTED CITY EXISTING BARN EFFLUENT GRAVITY SEWER 4 (S-3) RA-STD-274-2, (S-4) RA-STD-256 - — (S-9) RA-STD-261-1, (S-4) RA-STD-277 LL S-1 DIGESTER INFLUENT GRAVITY 1 (S-9) RA-STD-267 ' 4 SEWER MODIFICATION -• _ , �p5 -- - REQUIRED S-2 DIGESTER EFFLUENT FORCED WATER TRANSFER 1 r - � I S-3 WET WELL YES 1 �, .. � •- � - *— -- � - � (S-2) RA-STD-295 S-4 COVE R/RAIN WATER REMOVAL YES 2 S-5 NOT USED •- � DIGESTER 82.00 S-6 POWER FLUSH YES 1 EFFLUENT \ ���- � - S-7 SLUDGE REMOVAL YES 1 a LAGOON 27050 � - r o S-8 EMERGENCY VENT YES 2 �� i S-9 BIOGAS INTERFACE YES 1 .0010 , S-7 CI DIGESTER RA-STD-264 $0/ � 1 o� o PARAMETER VALUE UNITS WTL WTL .� LENGTH 240 FT - WI DTH 130 FT 1 0 '+ TOP OF DIKE ELEVATION 82 FT - - — DEPTH 12 FT I o BOTTOM ELEVATION 70 FT l� 70.00 27550 �� DIKE WIDTH 12 FT (S-8) RA-STD-255 I INTERIOR SLOPE 3:1 �rLmiL 0 EXTERIOR SLOPE 4:1 OPERATING HEIGHT 10 FT _ OPERATING ELEVATION 80 FT + LOW DIGESTER OPERATING HEIGHT N/A FT TEMPORARY FLARE � —"��— LOW DIGESTER OPERATING ELEVATION N/A FT MIN. 50' AWAY FROM EDGE OF DIGESTER OPERATING VOLUME 1325932 GAL TOTAL VOLUME 1760249 GAL DIGESTER .I, \ INFLUENT----- _ CUT 4357 CY FILL 4357 CY ' I I NET 1 0 CY qk PIPE o 78' - SERVICE SIZE SPECIFICATION QTY UNITS r RA-STD-266 BARN EFFLUENT (GRAVITY) 12" PL01 700 FT \ -- S-4 EXISTING BARN EFFLUENT (FORCED) N/A N/A N/A N/A RA-STD-277 & RA-STD-256 po LIFT STATION OVERFLOW 12" HP01 50 FT - GRAVITY TRANSFER OVERFLOW DIGESTER INFLUENT (FORCED) 611 HP02 N/A FT PROPOSED GAS LINE DIGESTER INFLUENT (FORCED) 1011 HP02 N/A FT 106.00 DIGESTER INFLUENT CLEANOUT X" PL01 N/A EA 105.00 DIGESTER EFFLUENT (FORCED) 611 HP02 250 FT WATER TRANSFER WET WELL LATERAL 1211 HP01 50 FT DIGESTER EFFLUENT (GRAVITY) 12" HP01 N/A FT WET WELL LATERAL N/A N/A N/A FT 102.00 COVER WATER SUCTION 311 HP01 80 FT _ COVER WATER DISCHARGE 311 HP02 200 FT POWER FLUSH 6" HP02 100 FT F _ '°o�n SLUDGE REMOVAL 12" HP02 50 FT +•' • j r "` 99.00 �� °`goo i i MIXING SUCTION 8 HP02 50 FT I :''"` '-� MIXING DISCHARGE 611 HP02 285 FT On _Awl - CD �o `_ C) JI 1°6 O - o po _ • TRUE NORTH AREA 1000 DONNA SMITH 27050 LOCATION DETAIL N� 11111111111� BAR �''� D 16JULY24 ISSUED FOR PERMITTING ZTS C 22SEP23 ISSUED FOR GROWERS MEETING LMB LMB ZL MK SCALE 1 SIZE MILLIMETERS: 1 =250 E MONARCH B I O E N E RGY �,,.•S•••••, �� ���E / �/Jj z Q -� B 05SEP23 ISSUED FOR GROWERS MEETING ZTS ZTS ZL MK A 11AUG23 ISSUED FOR GROWERS MEETING ZTS ZTS ZL MK DIMENSION TOLERANCE ±X -±010 (UNLESS OTHERWISE XXX=±0.010 SPECIFIED) ANGLES =±0.5' PINK HILL NC RO E S L E I N • • L# V�56059 REV DRWN CHK'D APP'D DATE REVISION DESCRIPTION gy BY By BY 7 FRACTIONS:INCHES:AREAOOO m �n THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC AND IS PROTECTED UNDER STATE AND FEDERAL LAW, INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et seq. ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC RESERVES ALL PATENT, COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL MACHINED PARTS -±1/64 .X =±.020 HOLE LOCATIONS ON =±1/32 .XX =±.010 DONNA SMITH WELDED ASSEMBLIES - ^4,G� / •N� ,�•\!•����� GRAN ED TOO HET S. THIS DOCUMENT IMUST NOT BE DUPLICATED ON, USE, AND SALES TOR DISCLOSED, IN WHOLE OR INETO, EXCEPT TO THE TPART, WITHOUT THE EXPRESS ENT SAID RIGHTS ARE EXPRESSLY PERMISSION CIATES, INC. AND ROESLEiN ALTERNATIVE NERGY, LLC. ANY USE OF THE OENERGEEN IIRICTHIS _ LINEAR STRUCTURAL WEOLDMENTS =±1/16 ANGLES XX=±.0502 ENGINEERS MANUFACTURERS •CONSTRUCTORS SHEET PROVIDEDOIDISNWRITTEN AND ROESLESN ALTERNATIVE/CH IT HAS DLOY PROHNBITOTHER THAN BY THE ED. UPONOTHE REQUEST OF ROEDSLEINIPIENT FOR THE& ASSOCIATES, NC EXPRESS YO, LLC ANGLES =±1 NEW DIGESTER DETAIL DWG • _ RA270 00 27050 OF 4 6 C ZACHARY STEWART 8/6/2024 3:49:14 PM C:\VAULT\PROJECTS\MONARCH BIO ENERGY\REGISTER NC\CADD\01 RA270\ORTHOS\DWGS\00 GENERAL ARRANGEMENTS\RA270-00-27050.DWG THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIES THEREOF IN ITS POSSFSSION.©2023ROESLEIN&ASSOCIATESE ,INC.ANDROESLFINALRNATIVEENERGY,LLc DO NOT SCALE PRINT NO. NOTE: INVERTS OF EXISTING GRAVITY PIPING ARE APPROXIMATED BASED ON BEST AVAILABLE SURVEY INFORMATION. 130 130 LEGEND: TOB: TOP OF BANK ELEVATION FF: FINISHED FLOOR ELEVATION FB: FREEBOARD ELEVATION EG: EXISTING GRADE ELEVATION OL: OPERATING LEVEL ELEVATION INV: INVERT ELEVATION SHWT: SEASONAL HIGH WATER TABLE - LIQUID FLOW DIRECTION AMILTON 9/26/2024 8:19:53 AM P:\200599\06-DRAWINGS\CIVIL\AlK\REGISTER-CLUSTER 2\AFO PERMIT DRAWINGS\27050 DONNA SMITH AFO PERMIT.DWG EXCAVATION SPECIFICATIONS 1. PROTECTION OF PERSONS AND PROPERTY 1 .1. THE CONTRACTOR SHALL PROTECT STRUCTURES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING, WASHOUT AND OTHER HAZARDS CREATED BY EARTHWORK OPERATIONS. 1.2. ANY SETTLEMENT IN BACKFILL FILL OR IN STRUCTURES BUILT OVER THE BACKFILL OF FILL, WILL BE CONSIDERED TO BE CAUSED BY IMPROPER COMPACTION METHODS AND SHALL BE CORRECTED AT THE CONTRACTOR'S SOLE EXPENSE. ALSO, ANY STRUCTURES DAMAGED BY SETTLEMENT SHALL BE RESTORED TO THEIR ORIGINAL CONDITION BY THE CONTRACTOR AT HIS SOLE EXPENSE. 2. DEWATERING 2.1. PUMPING EQUIPMENT SHALL BE PROVIDED AND EMPLOYED TO PREVENT RAINFALL AND SURFACE RUNOFF FROM ACCUMULATING OR FLOWING INTO EXCAVATIONS AND FROM FLOODING THE PROJECT SITE AND SURROUNDING AREA. PROVIDE AND MAINTAIN PUMPS, SUMPS, SUCTION AND DISCHARGE LINES, AND OTHER DEWATERING SYSTEM COMPONENTS NECESSARY TO CONVEY WATER AWAY FROM THE EXCAVATIONS. THE DISPOSAL OF CONVEYED. WATER SHALL BE DIVERTED IN SUCH A MANNER THAT NATURAL DRAINAGE OF THE AREA SHALL NOT BE DISTURBED. 3. SOIL EROSION 3.1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREVENTION OF SOIL EROSION DURING CONSTRUCTION TO THE MAXIMUM EXTENT POSSIBLE TO COMPLY WITH ALL APPLICABLE NORTH CAROLINA SOIL EROSION LAWS AND REGULATIONS. THE CONTRACTOR WILL ERECT EROSION CONTROL MEASURES IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN, PRIOR TO COMMENCING LAND DISTURBING ACTIVITY. 4. STRIPPING 4.1. ALL VEGETATION SUCH AS BRUSH, HEAVY SODS. HEAVY GROWTH OF GRASS, DECAYED VEGETABLE MATTER, RUBBISH AND ANY OTHER UNSUITABLE MATERIAL WITHIN THE EXISTING PROJECT SITE SHALL BE STRIPPED OR OTHERWISE REMOVED PRIOR TO THE PLACEMENT OF EMBANKMENT. 5. EXCAVATION AND EMBANKMENT FOR SITE FEATURES 5.1. THE ROUGH EXCAVATION SHALL BE CARRIED TO THE NECESSARY DEPTH AS SHOWN ON THE PLANS, TO THE LINES, GRADES AND ELEVATION SHOWN OR AS DIRECTED BY THE ENGINEER, AND SHALL BE MADE SO THAT THE REQUIREMENTS FOR FORMATION OF EMBANKMENTS CAN BE FOLLOWED. ON EMBANKMENT, THE DEPTH OF SUBGRADE DENSIFICATION SHALL BE AS SHOWN ON THE PLANS. SHOULD THE CONTRACTOR, THROUGH NEGLIGENCE OR OTHER FAULT, EXCAVATE BELOW THE DESIGNATED LINES, HE SHALL REPLACE THE EXCAVATION WITH APPROVED MATERIALS, IN AN APPROVED MANNER AND CONDITION, AT HIS OWN EXPENSE. CONTROL OVER THE EXCAVATION. MOVING, PLACING AND DISPOSITION OF ALL MATERIAL AND SHALL DETERMINE THE SUITABILITY OF MATERIAL TO BE PLACED IN EMBANKMENTS. ALL MATERIAL DETERMINED UNSUITABLE SHALL BE DISPOSED OF IN WASTE AREAS OR AS DIRECTED AND SHALL BE REPLACED WITH SELECT MATERIALS DEEMED SUITABLE BY THE ENGINEER. TOPSOIL SHALL NOT BE USED IN SUBGRADES BUT SHALL BE HANDLED AND PLACED AS DIRECTED. SHOULD EXCESS MOISTURE BE ENCOUNTERED DURING EXCAVATION IN THE CONSTRUCTION AREAS, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PERFORM ANY NECESSARY DEWATERING OF THE SITE IN ORDER TO PROVIDE A STABLE EXCAVATED AREA FOR THE PLACEMENT OF EMBANKMENT. THE ENGINEER RESERVES THE RIGHT TO MAKE MINOR ADJUSTMENTS OR REVISIONS IN LINES OR GRADES, IF FOUND NECESSARY. AS THE WORK PROGRESSES DUE TO DISCREPANCIES IN THE PLANS OR TO OBTAIN SATISFACTORY CONSTRUCTION. 5.2. STONES OR ROCK FRAGMENTS LARGER THAN 2" IN THE GREATEST DIMENSION WILL NOT BE PERMITTED IN THE TOP 5" OF THE SUBGRADE. 6. FORMATION OF EMBANKMENTS 6.1. EMBANKMENTS SHALL BE FORMED OF SATISFACTORY MATERIALS PLACED IN SUCCESSIVE HORIZONTAL LAYERS OF NOT MORE THAN 6" IN COMPACTED DEPTH FOR THE FULL WIDTH OF THE CROSS SECTION. THE GRADING OPERATIONS SHALL BE CONDUCTED. AND THE VARIOUS SOIL STRATA SHALL BE PLACED, TO PRODUCE A SOIL STRUCTURE AS SHOWN ON THE TYPICAL CROSS SECTION OR AS DIRECTED. ALL MATERIALS ENTERING THE EMBANKMENT SHALL BE REASONABLY FREE OF ORGANIC MATTER SUCH AS LEAVES, GRASS, ROOTS, AND ANY OTHER OBJECTIONABLE MATERIAL. 6.2. OPERATIONS ON EARTHWORK SHALL BE SUSPENDED AT ANY TIME WHEN SATISFACTORY RESULTS CANNOT BE OBTAINED BECAUSE OF RAIN, FREEZING WEATHER. OR OTHER UNSATISFACTORY CONDITIONS IN THE FIELD. THE CONTRACTOR SHALL DRAG, BLADE OR SLOPE THE EMBANKMENT TO PROVIDE PROPER SURFACE DRAINAGE AT ALL TIMES. 6.3. THE MATERIAL IN THE LAYERS SHALL BE OF PROPER MOISTURE CONTENT BEFORE ROLLING TO OBTAIN THE PRESCRIBED COMPACTION. WETTING OR DRYING OF THE MATERIAL AND MANIPULATION WHEN NECESSARY TO SECURE A UNIFORM MOISTURE CONTENT THROUGHOUT THE LAYER SHALL BE REQUIRED. SHOULD THE MATERIAL BE TOO WET TO PERMIT PROPER COMPACTION OR ROLLING, ALL WORK ON ALL PORTIONS OF THE EMBANKMENT THUS AFFECTED SHALL BE DELAYED UNTIL THE MATERIAL HAS BEEN DRIED TO THE PROPER MOISTURE CONTENT. SPRINKLING SHALL BE DONE WITH APPROVED EQUIPMENT THAT WILL SUFFICIENTLY DISTRIBUTE THE WATER. SUFFICIENT EQUIPMENT TO FURNISH THE REQUIRED WATER SHALL BE AVAILABLE AT ALL TIMES. 6.4. THE EMBANKMENT SHALL BE COMPACTED TO NOT LESS THAN 95% OF THE MAXIMUM STANDARD PROCTOR DENSITY AT OPTIMUM MOISTURE. DURING CONSTRUCTION OF THE EMBANKMENT, THE CONTRACTOR SHALL ROUTE HIS EQUIPMENT AT ALL TIMES, BOTH WHEN LOADED AND WHEN EMPTY, OVER THE LAYERS AS THEY ARE PLACED AND SHALL DISTRIBUTE THE TRAVEL EVENLY OVER THE ENTIRE WIDTH OF THE EMBANKMENT. CARE SHALL BE TAKEN. HOWEVER, NOT TO OVERLOAD THE EMBANKMENT AREA WITH CONSTRUCTION EQUIPMENT. 6.5. IN THE CONSTRUCTION OF EMBANKMENTS, STARTING LAYERS SHALL BE PLACED IN THE DEEPEST PORTION OF THE FILL; AS PLACEMENT PROGRESSES, LAYERS SHALL BE CONSTRUCTED APPROXIMATELY PARALLEL TO THE FINISHED PAVEMENT GRADE LINE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF ALL EMBANKMENTS MADE UNDER THE CONTRACT AND SHALL REPLACE ANY PORTION WHICH, IN THE OPINION OF THE ENGINEER. HAS BECOME DISPLACED DUE TO CARELESSNESS OR NEGLIGENCE ON THE PART OF THE CONTRACTOR. 7. TESTING 7.1. THE OWNER WILL PROVIDE THE SERVICES OF AN INDEPENDENT SOILS TESTING FIRM FOR PERFORMING TESTS AS ARE REQUIRED TO IDENTIFY MATERIALS, TO DETERMINE COMPACTION CHARACTERISTICS,TO DETERMINE MOISTURE CONTENT, AND TO DETERMINE DENSITY OF FILL IN PLACE. THESE TESTS PERFORMED WILL BE USED TO VERIFY THAT THE FILLS CONFORM TO THE REQUIREMENTS OF THE SPECIFICATIONS. TEMPORARY SEEDING CHART SPECIES PLANTING DATES LBS/ACRE CEREALS: RYE/WHEAT 8/15-12/30 120 MILLETS/SUDANGRASS 4/15-8/15 40 ANNUAL LESPEDEZA 12/1-4/15 50 1. FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. 2. APPLY 4,000 .B/ARE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. 3. IF GROWTH IS LESS THAN FULLY ADEQUATE, REFERTILIZE IN THE SECOND YEAR ACCORDING TO SOIL TESTS OR TOPDRESS WITH 500 LB/ARE 10-10-10 FERTILIZER, RESEED, REFERTILIZE, AND MULCH AREA IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. IF SEEDING IN FALL, TOPDRESS WITH 50 LB/ACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/ACRE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. PERMANENT SEEDING CHART SPECIES PLANTING DATES LBS/ACRE COMMON BERMUDAGRASS 4/1-7/15 10 MILLETS/SUDANGRASS 4/1-7/15 10 ANNUAL LESPEDEZA 4/1-7/15 30 1. APPLY LIME AND FERTILIZER ACCRODING TO SOIL TESTS, OR APPLY 3,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 500 LB/ACRE 10-10-10 FERTILIZER. 2. APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR BY TACKING WITH ASPHALT, ROVING, NETTING, OR CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. 3. REFERTILIZE THE FOLLOWINGN APRIL WITH 50 LB/ACRE OF NITROGEN. REPEAT AS GROWTH REQUIRES. MAY BE MOWED ONLY ONCE A YEAR. WHERE A NEAT APPEARANCE IS DESIRED, OMIT LESPEDEZA AND MOW AS OFTEN AS NEEDED. STABILIZATION TIMEFRAME CHART SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS PRIMETER DIKES, SWALES, DITCHES, SLOPES 7 DAYS NONE SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES > 50' IN LENGTH ALL OTHER AREAS WITH SLOPES < 4:1 14 DAYS NONE POST 4'-0" MIN. 10' MIN. FENCE 4" MIN. WIDTH TRENCH & COMPACTED BACKFILL v o 6" Min �o v o v v GEOTEXTILE FILTER FABRIC SECTION A -A ATE TYPICAL SECTION 1. A STABILIZED PAD OF CRUSHED STONE SHALL BE LOCATED WHERE TRAFFIC WOOD POST (TYP) NOTES: WILL BE ENTERING OR LEAVING A CONSTRUCTION SITE OR FROM A PUBLIC STREET. FENCE 1. MINIMUM LONGITUDINAL SPLICE FABRIC 5' SPACING MAX OVERLAP SHALL BE 2' WITH A 2. STONE TO BE 2-3 INCH WASHED STONE (SURGE STONE) POST AT EACH END. SECURE FABRIC TO POSTS. 3. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT 2. SUPPORT FENCE REQUIRED TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC STREETS OR EXISTING GROUND z WITH SILT FENCE AROUND LINE g z DROP INLET OR WHEN USED PAVEMENT. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL ACROSS DITCH. STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY Lo 3. INSTALL AROUND INLETS AND MEASURES USED TO TRAP SEDIMENT. ADDITIONAL CUT AREAS. 4. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. TRENCH GROUND 5. WHEN NECESSARY, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT BOTTOM LINE TRENCH PRIOR TO ENTERING A PUBLIC STREET. WHEN WASHING IS REQUIRED, IT BOTTOM SHALL BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN. GENERAL NOTES: 6. FILTER FABRIC SHALL BE MIRAFI 500 OR EQUAL. 1. FENCE FABRIC SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A MINIMUM OF 6 LINE WIRES WITH 12" STAY SPACING. ('_�2DETAIL-CONSTRUCTION ENTRANCE 2. FILTER FABRIC SHALL BE MIRAFI 100 FABRIC OR EQUIVALENT. BURLAP CANNOT BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD MORE 27050 N.T.S. THAN 30 DAYS. MAINTENANCE NOTES: 1. FILTER BARRIERS SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY. 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL BE NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH STORM EVENT. THEY MUST BE REMOVED WHEN DEPOSITS REACH APPROXIMATELY 0.5 FT. IN DEPTH. 4. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE OR FILTER BARRIER IS NO LONGER REQUIRED SHALL BE DRESSED TO CONFORM WITH THE EXISTING GRADE, PREPARED AND SEEDED. 5. PROVIDE OUTLETS WITH SEDIMENT FENCE AT LOW SPOTS FOR DEWATERING LARGE AREAS (USE CLASS B STONE). DETAIL -SILT FENCE 27050 N.T.S. EROSION AND MAINTENANCE CONTROL SCHEDULE: 1. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NECESSARY REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN THE INTEGRITY OF ALL SUCH DEVICES. 2. ALL TEMPORARY/PERMANENT BASINS AND ROCK CHECK DAMS SHALL BE CLEANED OUT AND RESTORED TO ORIGINAL VOLUME WHEN THE SEDIMENT ACCUMULATES TO APPROXIMATELY ONE HALF OF THE DESIGN VOLUME. GRAVEL SHALL BE CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS. 3. SEDIMENT SHALL BE REMOVED FROM BEHIND THE SEDIMENT FENCE AND AT THE INLET PROTECTION SEDIMENT FENCE WHEN IT BECOMES APPROXIMATELY 6" DEEP AT THE FENCE. THE SEDIMENT FENCE SHALL BE REPAIRED AS NECESSARY TO PRESERVE THE INTEGRITY OF THE FENCE. 4. ALL SEEDED AREAS SHALL BE FERTILIZED. RESEEDED AND MULCHED AS NECESSARY TO ESTABLISH A VIGOROUS, DENSE VEGETATIVE COVER. COIL FIBER ROLLS TO BE CHECKED FOR INTEGRITY AND BE REPLACED OR REPAIRED AS NECESSARY AFTER EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NECESSARY REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN THE INTEGRITY OF ALL SUCH DEVICES. CHANNEL GRADE G 5' MIN 4" DIA. RIP RAP 2.5:1 MAX 1 FT THICK 1/2"-3/4" GRAVELLAYER 2.5:1 MAX & MAX. 3 DETAIL -TEMPORARY ROCK CHECK 7050) N.T.S. AMILTON 9/26/2024 8:19:58 AM P:\200599\06-DRAWINGS\CIVIL\AlK\REGISTER-CLUSTER 2\AFO PERMIT DRAWINGS\27050 DONNA SMITH AFO PERMIT.DWG TOP OF BERM HIGH PUMP OPERATING HEIGHT 0 N IItolvivIlol►VAI� :0rylyl :1110WIN 9:ICL'1I z CENTER OF PIPE 0 12" WET WELL LATERAL N DIGESTER OPERATING LEVELS TOP OF SLUDGE BOTTOM OF LAGOON SPIROS1623 3/5/2024 4:16:25 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-251-2.DWG NOTES: x A 80-MIL HDPE FLOATING COVER 0 M 60-MIL HDPE LINER COMPACT THE BOTTOM SOIL. ANCHOR TRENCH PLAN VIEW NOTE 1 PERIMETER PIPING NOTE 2 WELD COVER/LINER HERE 1. PERIMETER PIPING. SEE RA-STD-254 FOR DETAILS. 2. NO TRENCH; EXCAVATE FROM TURNDOWN OF LINER/COVER; BACK FILL AND COMPACT IN STAGES TO COVER LINER/COVER. SPIROS1623 5/3/2024 3:22:16 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\COVER DRAWINGS\DWG FILES\RA-STD-253-2.DWG 024 NOTES: DAYLIGHT OUT BERM DIGESTER EMERGENCY VENT PORT ELEVATION VIEW 2 1. TWO EMERGENCY VENTS REQUIRED PER LAGOON, ONE AT EACH END OF THE LAGOON FURTHEST FROM THE BARNS. SPIROS1623 6/20/2024 1:35:36 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\COVER DRAWINGS\DWG FILES\RA-STD-255-2.DWG 09/27/2024 NOTES: 1. 45' HOSE LENGTH IS BASED ON RAINWATER PUMP BEING CENTERED WITH THE CUSTOM STRAINER SEE DETAIL "F" HDPE STRAPS. SEE DETAIL "C" FLEXIBLE HOSE. SEE DETAIL "A" NOTE 5 EE- BALLAST PIPING C1l 55' 55' -J --�-- 30' COVER ANCHOR STRAPS CUSTOM STRAINER SEE DETAIL "E" SEE DETAIL "F" COVER RAINWATER REMOVAL SUCTION PIPE PLAN VIEW oni A DETAIL A: FLEX HOSE INSTALLATION NOTE 4 MALE CAMLOCKS NOTE 2 3"SDR 17 10' DETAIL E: COVER ANCHOR STRAPS FLEXIBLE HOSE. SEE DETAIL "B" RAINWATER REMOVAL PUMP SEE DETAIL "D" FOR PIPE ORIENTATION APRON (NOTE 3) APRON (NOTE MALE CAMLOCKS 3" SDR 17 NOTE 2 STD256- DISTANCE BETWEEN STRAP WELDS = 24" 42" DETAIL C: FLEX HOSE ANCHOR STRAPS L/\ I f\IJJIIJIV VVCLL.iLLi I V P1rRlJIV IIVLi I L J). SEE DETAIL "C". DETAIL B: FLEX HOSE INSTALLATION NOTE 4 APRON (NOTE 3) NC 6" U/'1LLFiJ I ririivv. STD�266-2 FLOATING COVER FLOATING COVER AND BEING 10' FROM THE EDGE OF THE COVER. CALCULATIONS ARE REQUIRED IF RAINWATER PUMP LOCATION DIFFERS. 2. WHEN INSTALLING, ENSURE THAT TRANSITION PIECES/CAMLOCKS WILL NOT TEAR COVER. 3. HDPE STRAPS & APRON SHALL BE SAME THICKNESS AS COVER MATERIAL. 4. SEE RA-STD-293 FOR RAINWATER FLEX HOSE ASSEMBLY DETAILS. 5. SEE RA-STD-257 FOR BALLAST PIPE DETAILS. FEMALE CAMLOCKS rn\ir-:Q PUMP SUCTION PIPE (3" SDR 17) ING COVER SPIROS1623 6/26/2024 9:00:04 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\COVER DRAWINGS\DWG FILES\RA-STD-256-2.DWG NnTF.q- SSPIROS1623 HIGH EFFLUENT LOW EFFLUENT FLOATING COVER 0 2 W_ NOTE 4 NOTE 5 2°/Q SLOPE BOTTOM OF TEE MUST BE ABOVE DIGESTER HIGH WATER LEVEL 5 ~1 NOTE 5 I NOTE 6 5 NOTE 3 BIOGAS DRAW -OFF INSTALLATION ELEVATION VIEW 6/13/2024 12:18:26 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\COVER DRAWINGS\DWG FILES\RA-STD-261-1.DWG 0:: Ovallm NO POCKETS 1� 1 3 NOTE 1 3 NOTES 7, 8, 9, 10 8" PERIMETER PIPING 1. SEE RA-STD-276 FOR BLOWER SKID ASSEMBLY DETAILS. 2. ELEVATION TO CHANGE WITH TOPOGRAPHY. 3. SEE DRAWING RA-STD-253 FOR ANCHOR TRENCH DETAILS. 4. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 5. 5. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 6. COVER CONTRACTOR TO SUPPLY MANUFACTURED BOOT. 7. SEE PIPING ALIGNMENT DRAWINGS FOR STUB UP LOCATION. 3. VALVE SHALL BE INSTALLED PRIOR TO COVER INSTALLATION. 3 9. BUTTERFLY VALVES SHALL BE INSTALLED IN THE OPEN POSITION AND TURNED CLOSED AFTER INSTALLATION. 10. BOLTS AT TOP OF BUTTERFLY VALVE CONNECTING TO ABOVE GRADE PIPING IS TO BE SUPPLIED BY ROESLEIN. )VER , 8" LINE TO ABOVE GRADE DRAW OFF 4" DRAIN LINE TO LAGOON 8" INVERTED TEE IN LINE WITH PERIMETER PIPING _ 611 w ry IY O _ U z Q LL O w w 0 0 - - - - - - - - ' BOTTOM OF ANCHOR TRENCH DETAIL A: BIOGAS EXTRACTION POINT SECTION VIEW 3 BILL OF DESCRIPTION MATERIALS TAG SPEC SIZE QTY 1 PIPE HP01 811 VARIES 2 PIPE HP01 411 20' 3 90 ELBOW HP01 8" 1 4 ECCENTRIC REDUCER HP01 8" x 4" 1 5 TEE HP01 8" 2 6 FLANGE ADAPTER HP01 8" 1 7 BACKUP RING HP01 811 1 8 MACHINE BOLT HP01 3/4" x 3" 8 9 BUTTERFLY VALVE BUF05 811 1 10 22.5 ELBOW HP01 411 1 SCALE SIZE E MILLIMETERS: xX =±o.io XXX=+0.010 ANGLES =±0.5° QQ ROESLEIN CX ASSOCIATES INC. RNG PIPING STANDARD AREA 1000 BIOGAS DRAW -OFF INSTALLATION DETAILS 3 24FE624 ADDED NOTE 10, REVISED BOLT SIZE CBE SJS CBE KPL 2 28JUN23 UPDATED BILL OF MATERIALS CBE SJS KPL CD 1 25MAY23 ISSUED FOR CONSTRUCTION CBE SJS KPL CD DIMENSION TOLERANCE (UNLESS OTHERWISE SPECIFIED) 0 03APR23 ISSUED FOR CONSTRUCTION CBE SJS KPL CD TM ROESLE� �T REV # DATE REVISION DESCRIPTION BY DRWN CHK'D By APP'D By FRACTIONS: MACHINED PARTS =±1/64 HOLE LOCATIONS ON '' WELDED ASSEMBLIES--1/32 LINEAR DIMENSIONS ON =±1/16 STRUCTURAL WELDMENTS ANGLES =±1 ' INCHES: X =±.020 .XX =±.010 .XXX =±.005ENGINEERS .XXXX=±.0002 ANGLES =±.05° • MANUFACTURERS • CONSTRUCTORS PROBy THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL ANDPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et seq. ROESLEIN & ASSOCIATES, INC. RESERVES ALL PATIENT, COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & ASSOCIATES, INC.. ANY USE OF THE INFORMATION CONTAINED IN THIS DOCUMENT OTHER THAN BY THE AUTHORIZED RECIPIENT FOR THE EXPRESS PURPOSE FOR WHICH IT HAS BEEN PROVIDED IS STRICTLY PROHIBITED. UPON THE REQUEST OF ROESLEIN & ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIES THEREOF IN ITS POSSESSION. ©2019 ROESLEIN &ASSOCIATES, INC. DWG. RA-STD-261-1 N O . SHEET OF 1 1 REV 3 D O NOT SCALE PRINT NOTFS- OPERATING WATER LEVEL r 1 3 NOTE 2 Ala ------ NOTE 1 1 GRAVITY TRANSFER WATER WET WELL INSTALLATION DETAIL ELEVATION VIEW �rrL 0.5% MIN 0 n �I NOTE 4 NOTE 5 0 A NOTE 6 6'-0" CONDENSATE FRETURN LINE a n 3 . . . 1. SEE RA-STD-253 FOR ANCHOR TRENCH INSTALLATION DETAILS. 2. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 3. 3. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 4. SEE RA-STD-272 FOR WET WELL HOUSING AND PIPING DETAILS. 5. SEE RA-STD-273 FOR PRECAST WET WELL DETAILS. 6. SEE RA-STD-274-2 FOR WET WELL LEVEL INDICATOR DETAILS. 0.5% MIN 1 EXISTING OPEN LAGOON SPIROS1623 6/25/2024 1:50:41 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-262-3.DWG 2024 AIf1TrC%. 3 2 41516 NOTE 2 NOTE 3 NOTE 4 6PIROS1623 3/7/2024 10:38:30 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-264-2.DWG FLOATING COVER 1 IRRIGATION SUCTION PLAN VIEW IRRIGATION SUCTION ELEVATION VIEW NOTE 1, 5 NOTE 6 1. ANCHOR PIPE TO KEEP FROM MOVING. 2. MINIMUM OF 15' FROM THE EDGE OF THE COVER. LOCATION TO BE VERIFIED BY FARM OPERATOR. 3. SEE DRAWING RA-STD-253 FOR ANCHOR TRENCH DETAILS. 4. BENTONITE SLEEVE TO EXTEND BACK FROM THE TOP OF THE PIPE PENETRATION BY AT LEAST 36". ALL BACKFILL PIPE IN TRENCHES SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. BENTONITE SEAL MINIMUM 6" AROUND THE FULL DIAMETER OF THE PIPE. BENTONITE SEAL TO EXTEND FULL WIDTH OF THE TRENCH. 5. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 4. 6. TOP OF PIPE NEEDS TO END 2' BELOW THE LOW EFFLUENT. SEE RA-STD-251 FOR OPERATING LEVELS. HIGH EFFLUENT LOW EFFLUENT NOTES: HDPE STRI 13 12 1 z 0 N 2 3 4 5 9lt NEW/EXISTING SEWER LINE 5'-0" 7 10' MAX - NOTE 1 w O TOP OF BERM z 10 FLOATING COVER NOTE 12 NOTE 2 NOTE 3 NEW SEWER LINE (NOTE 4) iDPE STRAP V V LI V 1 1 1 I I LLLL-1 I..;ALLAST 11 10 1 \ 3 NOTE 8 S' M 11 Lo w O z 91, MIXING SYSTEM LINE(NOTE 11) SEWER CLEANOUT ELEVATION VIEW HIGH PUMP OPERATING HEIGHT LOW PUMP NOTE 9 NOTE 9 NOTE 9 NOTE 9 NOTE 9 1. REFERENCE DIMENSION. REFER TO FARM OPERATOR FOR EXACT LOCATION. 2. SEE DRAWING RA-STD-253 FOR ANCHOR TRENCH DETAILS. 3. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 4. 4. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 5. TOP OF PIPE MUST BE 12" BELOW LOW LAGOON LEVEL. 6. DEPTH TO BE DETERMINED BY EXISTING SEWER PIPE BURIAL DEPTHS. 7. BUTTERFLY VALVES SHALL BE INSTALLED IN THE OPEN POSITION AND TURNED CLOSED AFTER INSTALLATION. 8. FOR CLAY LINED LAGOONS, SEE RA-STD-284 FOR EARTH ANCHOR INSTALLATION DETAILS. FOR PLASTIC LINED LAGOONS, SEE DETAIL "A". 9. VARIES. SEE PIPING ALIGNMENT DRAWINGS FOR PIPE SIZES. 10. BALLAST PIPE TO HAVE SAME SIZE AS SEWER PIPE. HDPE STRAP WELDED TO BALLAST PIPE AND SEWER PIPE. 11. SEE RA-STD-289 FOR MIXING SYSTEM DETAILS. 12. COVER CONTRACTOR TO SUPPLY MANUFACTURED BOOT. SPIROS1623 3/6/2024 4:20:41 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-265-2.DWG NnTF.q- c� . SEWER CLEANOUT NOTE I IIIII NOTE I IIIII 2 X 3 1 4 � 5 0 POWER FLUSH PLAN VIEW FLOATING COVER 0 N NOTE 1 TOP OF BERM NOTE 3 1 z 3 N if SEWER LINE 1 POWER FLUSH ELEVATION VIEW SSPIROS1623 12/7/2023 10:08:15 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-266.DWG '024 NOTE 5 SCALE SIZE E MILLIMETERS: :xx =±O:10 xxx=±0.010 ANGLES =±0.5° 1 28JUN23 UPDATED BILL OF MATERIALS CBE SJS KPL MDC DIMENSION TOLERANCE (UNLESS OTHERWISE SPECIFIED) 0 08JUN23 ISSUED FOR CONSTRUCTION CBE SJS KPL MDC REV DATE REVISION DESCRIPTION BY DRWN CHK'D APP'D FRACTIONS: MACHINED PARTS =±1/64 INCHES: 4 BY BY BY THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, =±.020 INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et seq. ROESLEIN & ASSOCIATES, INC. RESERVES ALL PATIENT, HOLE LOCATIONS ON =±1/32 .X =±.010 COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, WELDED ASSEMBLIES .XX XXX =±.005 USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT LINEAR DIMENSIONS ON XXXX=±.0002 MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & =±1/16 STRUCTURAL WELDMENTS ASSOCIATES, INC.. ANY USE OF THE INFORMATION CONTAINED IN THIS DOCUMENT OTHER THAN BY THE AUTHORIZED RECIPIENT ANGLES =±.05° FOR THE EXPRESS PURPOSE FOR WHICH IT HAS BEEN PROVIDED IS STRICTLY PROHIBITED. UPON THE REQUEST OF ROESLEIN & ANGLES =±1 ° ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALLCOPIE /� DO NOT SCALE f� PRINT THEREOF INSITS (92019 ASSOCIATES, ©2019 ROESLEIN &ASSOCIATES, INC. J 1. REFER TO FARM OPERATOR FOR EXACT LOCATION. 2. 6" POWER FLUSH INSTALLED APPROXIMATELY 18" ADJACENT TO SEWER LINE CLEANOUT. SEE RA-STD-265 FOR DETAILS. 3. SEE DRAWING RA-STD-253 FOR ANCHOR TRENCH DETAILS. 4. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 5. 5. A BENTONITE SLEEVE, 611 MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. HIGH PUMP LOW PUMP LOW LAGOON NOTE 4 1 BILL OF MATERIALS TAG DESCRIPTION SPEC SIZE QTY 1 PIPE FLANGE ADAPTER HP02 6" 609 2 HP02 6" 1 3 BACKUP RING HP02 6" 1 4 GASKET STUD BOLTS W/ NUTS HP02 6" 1 8 5 HP02 3/4" x 4%4" LG 6 BLIND FLANGE HP02 6" 1 ROESLEIN & ASSOCIATES, INC. RNG PIPING STANDARD ROESLEIN. AREA 1000 POWER FLUSH ENGINEERS • MANUFACTURERS • CONSTRUCTORS INSTALLATION DETAILS DWG. SHEET REV NO. RA-STD-266 1 OF2 1 FOXMiM =1 FLOATING COVER 1 HIGH PUMP 1 3 I LOW PUMP LOW LAGOON OFF -SPEC DIGESTER TIE IN ELEVATION VIEW SSPIROS1623 12/7/2023 10:14:21 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-267.DWG 0 2 1 NOTE 2 1 2 U\ V MIN 1 5 C! NOTE 3 0:Q: n. ff": 3 w H O z TOP OF BERM/GRADE NOTE 4 SCALE SIZE E MILLIMETERS: XX=+00.50 XXX=±0.010 ANGLES =±0.5° 1 28JUN23 UPDATED BILL OF MATERIALS CBE SJS KPL MDC DIMENSION TOLERANCE (UNLESS OTHERWISE SPECIFIED) 0 08JUN23 ISSUED FOR CONSTRUCTION CBE SJS KPL MDC REV DATE REVISION DESCRIPTION BY DRWN CHK'D APP'D FRACTIONS: MACHINED PARTS =±1/64 INCHES: # BY BY BY THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, =±.020 INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et seq. ROESLEIN & ASSOCIATES, INC. RESERVES ALL PATIENT, HOLE LOCATIONS ON =±1/32 .X =±.010 COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, WELDED ASSEMBLIES .XX =±.005 USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT LINEAR DIMENSIONS ON .XXX =±.0002 MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & STRUCTURAL WELDMENTS .XXXX ASSOCIATES, INC.. ANY USE OF THE INFORMATION CONTAINED IN THIS DOCUMENT OTHER THAN BY THE AUTHORIZED RECIPIENT ANGLES =±.05° FOR THE EXPRESS PURPOSE FOR WHICH IT HAS BEEN PROVIDED IS STRICTLY PROHIBITED. UPON THE REQUEST OF ROESLEIN & ANGLES =±1 ° ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL /� DO NOT SCALE L E PRINT COPIES THEREOF IN ITS POSSESSION. ©2019 ROESLEIN &ASSOCIATES, INC. J /'1 1. DEPTH AS REQUIRED BY PIPING ALIGNMENT DRAWINGS. NO SLOPING REQUIREMENT ON INCOMING OFF SPEC GAS LINE. 2. SEE RA-STD-253 FOR ANCHOR TRENCH INSTALLATION DETAILS. 3. BUTTERFLY VALVES SHALL BE INSTALLED IN, 1 THE OPEN POSITION AND TURNED CLOSED AFTER INSTALLATION. 4. SEE PIPING ALIGNMENT DRAWINGS FOR OFF -SPEC PIPE SIZE. 1 BILL OF MATERIALS TAG DESCRIPTION SPEC SIZE QTY 1 PIPE HP01 8" 25' 2 TEE HP01 8" 1 3 REDUCER, ECCENTRIC HP01 8" x 4" 1 4 90 ELBOW HP01 811 5 5 BUTTERFLY VALVE BUF05 811 1 6 FLANGE ADAPTER HP01 811 2 7 BACKUP RING HP01 811 2 8 MACHINE BOLT HP01 3j4° x 3° 16 ROESLEIN & ASSOCIATES, INC. RNG PIPING STANDARD ROESLEIN. AREA 1000 OFF -SPEC CONNECTION ENGINEERS • MANUFACTURERS • CONSTRUCTORS INSTALLATION DETAILS DWG. SHEET REV NO. RA -STD -267 1 OF2 1 NOTFS- tl off 7f nil &If BEN MINI ARC DIAL PIPE THE OF l c u PENETRATION REPAIR PATCH 'PLATE TO SKIRT D PERIMETER CA/I171TIAIf- I Irli= EXISTING LINER PENETRATION DETAIL 1. BENTONITE SLEEVE TO EXTEND BACK FROM THE TOP OF THE PIPE PENETRATION BY AT LEAST 36". 2. ALL BACKFILL IN PIPE TRENCHES SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. SPIROS1623 12/8/2023 11:52:34 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-270.DWG KinTF.q- L------L BACK TO OPEN LAGOON / WET WELL NOTE 4, 5 TE 2, 3 Cnl IAI Cnl I A I INSTALLED BY UNDERGROUND PIPING CONTRACTOR 27 27 31 31 125 DISCHARGE 4 3 RAINWATER REMOVAL PUMP ELEVATION VIEW NOTE 7 RAINWATER REMOVAL PUMP PLAN VIEW SSPIROS1623 3/6/2024 4:23:02 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-271-3.DWG NOTE 6 17 INSTALLED BY UNDERGROUND PIPING CONTRACTOR F --- I I 16 I I ---------- ------------r--------- 20 I I NOTE 2,3 I I I I I I q I I I I I I GRADE I I � I I L-- - - - - - I TO LOCAL DISCHARGE STATION 2024 1. SEE LOCAL GENERAL ARRANGEMENTS, SUPPORT DETAILS, AND PANEL MOUNTING INFORMATION. 2. ELECTROFUSION COUPLER NEEDED IF DISCHARGE OF PIPE IS LESS THAN 3 FEET ABOVE GRADE. 3. ELECTROFUSION COUPLINGS PROVIDED BY INSTALLING CONTRACTOR. 4. COVER WATER FLOW BACK INTO LAGOON UNDER COVER WHEN WATER TESTS HOT FOR EFFLUENT. 5. SEE RA-STD-260 FOR UNDER COVER RETURN. 6. INSTALL FEMALE CAMLOCK CAP - ITEM 13 ON THE B.O.M. - ON PIPE TO LAND DISCHARGE. 7. SEE RA-STD-293 FOR RAINWATER FLEX HOSE ASSEMBLY DETAILS. 8. BUTTERFLY VALVES SHALL BE INSTALLED IN THE OPEN POSITION AND TURNED CLOSED AFTER INSTALLATION. BILL OF MATERIALS TAG DESCRIPTION 1 BALL VALVE - BAT02 - CL 800 FNPT 2 WATER HOSE ADAPTER, THREADED MALE OUTLET 3 BALL VALVE, BAT02 - CL800 THREADED 4 PIPE, NIPPLE, SCH 80 CARBON STEEL ERW, GALVANIZED, THREADED ENDS 5 WELD OUTLET, CARBON STEEL, 3000 LB, THREADED FEMALE OUTLET (THREAD-O-LET) 6 FLANGE, THREADED, GALVANIZED CARBON STEEL, 150 LB, RAISED FACE, BORE TO SCH 80 7 GASKET, GARLOCK 3000 NITRILE GASKET OR EQUL, %8" THICK 8 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 9 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 10 LUG BOLT, A193 GR B7 / W(2) ASTM A194 GR 2H HEAVY HEX NUTS TEFLON COATED 11 BUTTERFLY VALVE - BUF02 - CL 150, THREADED 12 FLANGE, 304 SS, RF, CL 150, THREADED 13 CAMLOCK CAP, FEMALE, 304 SS 14 MALE CAMLOCK, 304 SS, THREADED MALE OUTLET 15 FEMALE CAMLOCK, THREADED FEMALE OUTLET, 304SS 16 TRANSITION FITTING, HDPE SDR 17 TO 304 SS (M) NPT 17 MALE CAMLOCK, THREADED FEMALE OUTLET, 304 SS 18 90 ELBOW, HDPE SDR 17, PE4710 ASTM D3261 IPS 19 PIPE, HDPE, PE4710, SDR 17, DIMENSIONS PER ASTM F2619 20 ELECTROFUSION COUPLERS 21 EXTRA NITRITE O-RINGS FOR CAMLOCKS 22 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 23 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 24 90 ELBOW, GALVANIZED MALLEABLE IRON, CL150, THREADED ENDS, SCH 80 25 FLANGE, THREADED, GALVANIZED CARBON STEEL, 150 LB, RAISED FACE, BORE TO SCH 80 26 TYPE A - ALUMINUM CAMLOCK FITTING 27 LUG STUD TEFLON COATED A193 GR B7 / W(2) ASTM A194 GR 2H HEAVY HEX NUTS TEFLON COATED 28 WELD OUTLET, CARBON STEEL, 3000 LB, THREADED FEMALE OUTLET (THREAD-O-LET) 29 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 30 BALL VALVE - BAT02 - CL 800 THREADED 31 GASKET, GARLOCK 3000 NITRILE GASKET OR EQUAL, %8" THICK SCALE SIZE E MILLIMETERS: :X _±05Xx XXX=±0.010 ANGLES =±0.5° ROESLEIN & ASSOCIATES, INC. R N G PIPING STANDARD DIMENSION TOLERANCE (UNLESS OTHERWISE SPECIFIED) REV DATE REVISION DESCRIPTION B�, DRWN By CHK'D By APP'D By # FRACTIONS: INCHES: r,r,r, AREA 1000 THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, MACHINED PARTS =±1/64 =±.020 IN & ASSOCIATES, INC. RESERVES ALL PATIENT, INCLUDING 18 USC SECTION PRI AND 17 USC SECTION 101 C seq. T, INCLUDING COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, HOLE LOCATIONS ION E =±1/32 WELDED ASSEMBLIES .X .XX =±.010 XXX =±.005 RAINWATER REMOVAL PUMP USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT LINEAR DIMENSIONS ON =±.0002 MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & ASSOCIATES, INC.. ANY USE OF THE INFORMATION CONTAINED IN THIS DOCUMENT OTHER THAN BY THE AUTHORIZED RECIPIENT =±1/16 STRUCTURAL WELDMENTS .XXXX ANGLES =±.05° FOR THE EXPRESS PURPOSE FOR WHICH IT HAS BEEN PROVIDED IS STRICTLY PROHIBITED. UPON THE REQUEST OF ROESLEIN & ANGLES =±1 ° PIPING DETAILS ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL DO NOT SCALE PRINT f� IN COPIE@2019 OESTHEREOF ©2019 ROESLEIN &ASSOCIATES, INC. IN&ASS CIATES,INC. SPEC SIZE QTY CS05 1" 1 SP-1006B-XX 3/4" NPT (M) x 3/4" 1 CS05 3/4„ 1 CS05 3/4" x 4" 1 CS05 OUTLET 3/4", HEADER 1%2" 1 CS05 3" 1 CS05 3" 2 CS05 1 " x 4" 1 CS05 3" x 8" 1 CS05 5/8" X 13/4" g CS05 3" 2 CS05 3" 1 S P-1007-A-XX 3" 1 S P-1007 B-XX 3" 1 SP-1007C-XX 3" 2 H P02 3" 3 SP-1007D-XX 3" 2 H P02 3" 2 H P02 3" 10, HP02 3" AS NEEDED SP-1007E-XX 3" 2 CS05 3" x 12" 1 CS05 3" x 8" 2 CS05 3" 1 CS05 3" 2 S P-1008A-XX 3" 1 H P02 5/8" X 13/4" 24 CS05 OUTLET %2", HEADER 3/4" 1 CS05 j2" x 4" 1 CS05 %2" 1 H P02 3" 4 ENGINEERS • MANUFACTURERS • CONSTRUCTORS DWG. SHEET REV NO. RA -STD -271-3 1 OF 1 FRONT VIEW NOTES: 1. INSTALL AT TOP OF BERM GRADE. 2. FASTEN TO SIDE OF WET WELL USING GALVANIZED PIPE HANGER STRAPS. V SPIROS1623 6/25/2024 2:19:20 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-274-2.DWG NOTES: NOTES: SPIROS1623 6/26/2024 9:56:24 AM A � Cl STD-277 PIPE OUTLET TO FLAT AREA — NO WELL DEFINED CHANNEL PLAN VIEW L Li a SECTION A STD-277 S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-277.DWG 1. THE ROCK RIPRAP SHALL MEET NCDOT REQUIREMENTS FOR CLASS "B" RIP RAP (100 LBS./FT3) OR AS DESIGNATED BY ENGINEER. 2. APRON WIDTH "W1" SHALL BE AT LEAST 2 TIMES THE CULVERT PIPE DIAMETER. APRON WIDTH "W2" SHALL BE AT LEAST "L" PLUS THE PIPE DIAMETER. 3. ROCK THICKNESS 'IT" SHALL BE AT LEAST 1.5 TIMES THE RIP RAP D100 SIZE. 4. APRON LENGTH "L" AND ROCK RIP RAP SHALL BE SIZED ACCORDING TO ENGINEERS SPECIFICATIONS, MINIMUM 111—"=4 x "D" FT. 5. "T" = 15" CLASS "I" RIP RAP, UNLESS OTHERWISE SHOWN ON PLANS. 6. "T" = 12" CLASS "B" RIP RAP, UNLESS OTHERWISE SHOWN ON PLANS. Ed R;EV DATE REVISION DESCRIPTION BY DKWBYN ` BYD A BY THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et seq. ROESLEIN & ASSOCIATES, INC. RESERVES ALL PATIENT, COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & ASSOCIATES, INC.. ANY USE OF THE INFORMATION CONTAINED IN THIS DOCUMENT OTHER THAN BY THE AUTHORIZED RECIPIENT FOR THE EXPRESS PURPOSE FOR WHICH IT HAS BEEN PROVIDED IS STRICTLY PROHIBITED. UPON THE REQUEST OF ROESLEIN & ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIES THEREOF IN ITS POSSESSION. ©2019 ROESLEIN & ASSOCIATES, INC. PIPE OUTLET TO WELL DEFINED CHANNEL PLAN VIEW B SECTION B ST -277 SCALE SIZE E MILLIMETERS: DIMENSION TOLERANCE x =±0.5 XX =±0.10 (UNLESS OTHERWISE xxx =±O.o10 SPECIFIED) ANGLES =±0.51 FRACTIONS: INCHES: MACHINED PARTS =±1/64 HOLE LOCATIONS ON X =±.020 WELDED ASSEMBLIES -±1/32 XX =±.010 XXX =±.005 LINEAR DIMENSIONS ON =±1/16 XXXX =±.0002 STRUCTURAL WELDMENTS ANGLES =±.05° ANGLES =±1° DO NOT SCALE PRINT L 1. THE ROCK RIPRAP SHALL MEET NCDOT REQUIREMENTS FOR CLASS "B" RIP RAP (100 LBS./FT3) OR AS DESIGNATED BY ENGINEER. 2. APRON WIDTH "W1" SHALL BE AT LEAST 1 TIMES THE CULVERT PIPE DIAMETER. APRON WIDTH "W2" SHALL BE AT LEAST "L" PLUS THE PIPE DIAMETER. 3. ROCK THICKNESS "T" SHALL BE AT LEAST 1.5 TIMES THE RIP RAP D100 SIZE. 4. APRON LENGTH "L" AND ROCK RIP RAP SHALL BE SIZED ACCORDING TO ENGINEERS SPECIFICATIONS, MINIMUM "L"=4 x "D" FT. 5. H = RIP RAP TO TOP OF PIPE (MAX. "H" = "D11 + „T„ 6. 'IT" = 15" CLASS "I" RIP RAP, UNLESS OTHERWISE SHOWN ON PLANS. 7. 'IT" = 12" CLASS "B" RIP RAP, UNLESS OTHERWISE SHOWN ON PLANS. TZ ROESLEIN & ASSOCIATES, INC. RNG PIPING STANDARD AREA 1000 RAINWATER OUTLET PIPING DETAIL ENGINEERS • MANUFACTURERS • CONSTRUCTORS DWG. SHEET REV NO. RA —STD —277 1 OF rl I LJL, LJI 17 LJI II 1 LEVEL SWITCHES LIFT STATION PLAN VIEW DETAIL A: LIFT STATION ELEVATION VIEW NOTE 4 IN UNDERGROUND PIPING CONTRACTOR'S SCOPE IN UNDERGROUND PIPING CONTRACTOR'S SCOPE 8" HDPE SDR 17 FORCED SEWER NOTES: 1. PIPE SIZES MAY VARY PER LIFT STATION, SEE PIPING ALIGNMENT DRAWINGS FOR SIZES. 2. SEE RA-STD-285 FOR PRECAST LIFT STATION FABRICATION DETAILS. 3. RAILING OR GRATING IS REQUIRED FOR LIFT STATIONS THAT EXTEND ABOVE GRADE LESS THAN 42". 4. SEE RA-STD-287 FOR VALVE BOX INSTALLATION DETAILS. 5. SIZES AND COMPONENTS MAY VARY PER VALVE BOX. SEE ALIGNMENT DRAWINGS AND ATTACHED TABLE FOR DETAILS. 6. PACKING MUST BE TIGHTENED AT INSTALL. 7. ROTATE OUT OF WAY OF OVERHEAD PIPE. FLOATS 1 ALARM HIGH WATER 2 PUMP OFF 3 LEAD PUMP ON 4 LAG PUMP ON SPIROS1623 3/6/2024 4:26:48 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GEN ERAL\RA-STD-280-2. DWG 024 A 1/1Trt-%_ z NOTE 2 N 0,:":":m TOP OF BERM aaa i l i i l i i l i i l i i l i i l i i � I I I NOTE 1 I EDGE OF BERM NOTE 4 z N vl- POWER FLUSH PLAN VIEW FLOATING COVER WET WELL POWER FLUSH ELEVATION VIEW LAGOON SLOPED WALL 1 3 NOTE 3 . MINIMUM OF 1 5' FROM EDGE OF THE COVER. REFER TO FARM OPERATOR FOR EXACT LOCATION. 2. 6" POWER FLUSH INSTALLED ADJACENT TO WET WELL LATERAL. 3. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 4. SEE RA-STD-2 53 FOR ANCHOR TRENCH DETAILS. HIGH PUMP LOW PUMP LOW LAGOON IROS1623 12/7/2023 10:52:52 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-282.DWG 2024 NOTES: 6 � 5 � 4 1 3 1 2 NOTE 4 1 NOTE 5 L 0.5% SLOPE 1 NOTE 3 1 � 1 OTE 6 3 FLOATING COVER 1 NOTE 1 97 GCS CONDENSATE RETURN INSTALLATION DETAILS ELEVATION VIEW 1. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 2. 2. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 3. SEE RA-STD-253 FOR ANCHOR TRENCH INSTALLATION DETAILS. 4. CONNECTS TO GCS CONDENSATE DISCHARGE. 5. SEE GENERAL ARRANGEMENTS FOR EXACT LOCATION. I-'6. COVER CONTRACT R TO SUPPLY MANUFACTURED BOOT. HIGH PUMP LOW PUMP LOW LAGOON SPIROS1623 3/6/2024 9:56:41 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-288.DWG 2024 2 -1 I I I I I I I I J� � L 3'-0" MIN. 3" SDR11 5 1 3 ART SYSTEM CONNECTION ELEVATION VIEW EVAPORATION LAGOON CONNECT TO INFUSER NOZZLE ISSPIROS1623 3/6/2024 4:31:01 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-295.DWG 2024