Loading...
HomeMy WebLinkAbout310095_Application Attachment - Digester Drawings_20241014DU LIN COUNTY, NORTH CAROLINA ADDRESS 1174 HWY 11, KENANSVILLE, NC LEGEND: KIRBY QUINN RD. � = RAINWATERCIVIL ENGINEER o� = GAS LINE _ \EW gRps LIFT STATION BR' pGE RD. MCCLURE 2001 W. BROADWAY = UNDERGROUND TELEPHONE COLUMBIA MO 65203 — = OVERHEAD ELECTRICAL 573-814-1 568 = STORM DRAIN = WATER TRANSFER LINE ELECTRICAL ENGINEER= GRAVITY OVERFLOW � = g03 ROESLEIN & ASSOCIATES, PROPERTY LINE N 9200 WATSON ROAD SUITE 200 = SET BACK LIMITATIONS ST. LOU IS, MO 63126 = OCCUPIED RESIDENCES SET BACK PRICE FARMS (314) 729-0055 0 = CHURCH & SCHOOL SET BACK = DIGESTER OPTIONS N ny ® = EXISTING POWER POLE TRUE NORTHSHEET INDEX �p COUNTY MAP � = CONCRETE BARRIER RA270-00-27101-1 - COVER & SHEET INDEX = EXISTING SEWER MODIFICATION SARECTA RD. �. RA270-00-27101-2 -AREA 1000 NEW DIGESTER GRADING �s� RA270-00-27101-3 - AREA 1000 PRICE FARMS SITE SET BACKS - DATA FROM FISH &WILDLIFE NATIONAL WETLANDS RA270-00-27101-4 -AREA 1000 GENERAL ARRANGEMENTS = 1 oo, WET WELL SET BACK RA270-00-27101-5 -AREA 1000 HYDRAULIC PROFILE RA270-00-27101-6 -AREA 1000 EROSION CONTROL VICINITY MAP LEGEND: = DUPLIN COUNTY I HEREBYCERTIFYTHATTHIS / ENGINEERING DOCUMENT WAS I I / BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION C L U R E PROFESSIONAL ENGINEER UNDER 0i O CA �i `�O��N.•......V RO� 0��� `�O�—'.��FEiA _ _ fS-8 'SPECIFIED) � _ S_ • • 6059 =� ASESHOWN 1111EE MILLIMETERS: — DIMENSION TOLERANCE .xx =±o.io 09JULY24 ISSUED FOR PERMITTING LMB ZTS JE (UNLESS OTHERWISE xxx _+0010PREPARED ANGLES =±0.5� REV DRWN CHK'D APP'D DATE REVISION DESCRIPTIONANDTHATIAMADULYLICENSED u BY eY eY FRACTIONS: INCHES: THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN &ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC AND IS PROTECTED UNDER STATE MACHINED PARTS =±1/64 _ _ .. __, ... PROTECTEDX =±.020 MONARCH BIO ENERGY KENANSVILLE NC 7M AREA 10 00 coN TRUE NORTH RO E� x Detail Drawing Control Index Sys. Sys. Description Drawing DWG Description General Drawings RA-STD-251 Typical Lagoon Operating Levels RA-STD-253 Anchor Trench Installation RA-STD-270 Liner Penetration Installation S-1 Digester Influent RA-STD-265 Sewer Cleanout RA-STD-269 Forced Sewer RA-STD-280 Lift Station Pump Piping RA-STD-285 Precast Lift Station S-2 Digester Effluent RA-STD-275 Transfer Water Discharge RA -STD- 295 ART System Connection S-3 Wet We I I RA-STD-272 Wet Well Piping RA-STD-274 Wet Well Level Indicator S-4 Cover/Rain Water RA-STD-256 Rainwater Removal Suction Pipe RA-STD-271 Rainwater Removal Pump RA-STD-277 Rain Water Outlet Detail S-5 Power Flush RA-STD-266 Power Flush RA-STD-282 Wet Well Power Flush S-6 Sludge Removal RA-STD-264 Irrigation Suction S-7 Emergency Vent RA-STD-255 Lagoon Vent Ports Bio as Interface gpTM RA-STD-261 Biogas Draw -Off RA-STD-267 Off-S ec Connection RA -STD- 288 Condensate Return ILBAGGETT4317 9/20/2024 2:54:40 PM C:\VAULT\PROJECTS\MONARCH BIO ENERGY\REGISTER, NC\CADD\01 RA270\ORTHOS\DWGS\00 GENERAL ARRANGEMENTS\RA270-00-27101.DWG GENERAL NOTES: 1. THE QUANTITIES SHOWN ON THIS PLAN ARE BASED ON ENGINEER'S CALCULATIONS REQUIRED TO ACHIEVE THE DESIRED GRADES. 2. VERIFY LOCATION OF ALL UTILITIES (BOTH ABOVE AND BELOW GROUND) PRIOR TO ANY EXCAVATION. CALL 811 PRIOR TO ANY EXCAVATION ACTIVITIES. 3. EROSION PROTECTION SHALL BE INSTALLED AT INLET LOCATIONS. 4. TOPSOIL STRIPPED FROM THE LAGOON SITE SHALL BE STOCKPILED ON -SITE FOR COVERING THE OUTSIDE OF THE BERMS. 5. EMBANKMENT MATERIALS SHALL BE FREE OF SOD, ROOTS, AND OTHER OBJECTIONALBLE MATERIALS. 6. ALL ELEVATIONS SHALL BE AT GRADE OR PLUS 0.1' OF DESIGN GRADE. 7. BERM FILL FOR THE PROPOSED LAGOON DIGESTER TO BE PLACED IN 6" LIFTS TO 95% OF STANDARD PROCTOR AT -1 % TO +3% OF OPTIMUM MOISTURE. 8. EACH 6" LIFT SHALL BE TESTED FOR MOISTURE/DENSITY BY A QUALIFIED GEOTECHNICAL LABORATORY APPROVED BY ENGINEER. A FAILING TEST REQUIRES REWORK OF AREA TO MEET SPECIFICATION. 9. THE INTERFACE SURFACE OF SUCCESSIVE LAYERS IS TO BE DISKED OR SCARIFIED PRIOR TO PLACEMENT OF SUBSEQUENT LAYERS OF CLAY. 10. ALL INSIDE AND OUTSIDE CUTS/FILLS ARE 3:1 UNLESS OTHERWISE NOTED. 11. NO OFF -SITE MATERIAL MAY BE IMPORTED FOR LAGOON LINING UNLESS APPROVED BY THE ENGINEER. 12. LAGOON TO BE LINED WITH 60-MIL THICK HDPE SYNTHETIC LINER. THE INSIDE WALLS OF THE LAGOON SHALL BE SMOOTH ROLLED PRIOR TO LINER INSTALLATION. 13. PROVIDE PROPER CONSTRUCTION AND WORKMANSHIP TO ENSURE NECESSARY SLOPES FOR DRAINAGE. Cut/Fill Summary Name Cut Factor Fill Factor 2d Area Cut Fill Net EX BARN 87.2 V V / ) / PIT: 5 r 11/� / \ _/ I _ ' f- � I EX BARN FF:88.25 pIT:88.25 - ij yL v/ EX LAGOON C l \ 1 \ 1 I 27601 B I \ \ lv f �I n 1 `\ J l I I \ I1( EX BARN FF:88.25 I � <� 1 00 00 / 1 \ EX BARN I FF:88.0 / I r_\ </ v 1 � 1 �I / fA / \ �s L NEW \ s° \ \ \ \ \ I EX BARN r,�- 1 _\ \� �.\ I DIGESTER �\ \ I � \ \ FT877 PI s Jr. \- r� o \ \ � v \\ \ \ • � I �' ��\ 1 L/ �� , EX LAGOON 9 FLOOR \ J / / \ / /� ll I111 I s \\ \\// // //— \ \ _� 1 EX BARN ���� \ 1 � 1 Pi $$ 0 c �- C `� /i�11 I I` \ \ � � �\ '`� `-- � `\ \ � , �`-\ , \ ,� \ _ �� 11 I`lh ,I111► l I � 726' \\ // \\ <� \ \�`<�\_. EX BARN FFa3.o /lll IIIIII I I 1 / PIT-.81.25 �I \ PIPE BRIDGE \1 / f r ✓84.60 7 I \ TOP OF BERM QTY-27101 PRICE FARMS 1.000 1.150 73168.83 Sq. Ft. 6119.74 Cu. Yd. 5862.41 Cu. Yd. 257.33 Cu. Yd.<Cut> Totals 73168.83 Sq. Ft. 6119.74 Cu. Yd. 5862.41 Cu. Yd. 257.33 Cu. Yd.<Cut> AMILTON 9/27/2024 4:18:47 PM P:\200599\06-DRAWINGS\CIVIL\A1 K\REGISTER-CLUSTER 3\AFO PERMIT DRAWINGS\27101 PRICE FARMS AFO PERMIT.DWG PROPERTY OWNER MATTHEWS, PROPERTY OWNER FLORES, APOLONIO & WIFE FLORES, RHONE 0 TRUE NORTH LBAGGETT4317 9/20/2024 2:54:42 PM C:\VAULT\PROJECTS\MONARCH B10 ENERGY\REGISTER, NC\CADD\01 ENERALARRANGEM 101.DWG i' 'I 8 SEWER INFLUENT LINE 4p MODIFICATIONS NEEDED L LIFT STATION 27601 B , OVERFLOW LINE I (S-1) RA-STD-285 1 EXISTING RECYCLE PUMP - ---- � (S-6) RA-STD-266 o d (S-4) RA-STD-256 & RA-STD-277 J11' /6. °0 270� 0 00 -,-` PROPOSED METER DROP RA-STD-280 DIGESTER INFLUENT L WTL 82-oIe I is Now co h — GO 7c, (S-1) RA-STD-285 27601A PROPOSED METER DROP WATER TRANSFER LINE WATER TRANSFER PUMP 0 0 (S-2) RA-STD-295 1 EXISTING �I RECYCLE - PUMP ;IL .1 _ X OPTION 1: LAGOON 27101 (S-9) RA-STD-261 & RA-STD-271 3 SEWER INFLUENT LINE MODIFICATIONS NEEDED 5 �- DIGESTER - EFFLUENT �M - PROPOSED GAS LINE (S-4) RA-STD-256 r I � & RA-STD-277 , r . , � {, ' � � _ _ - I�.,, _ fir• * * i IF 1 = r .y T 40 Aft 0 FARM PRODUCTION INFORMATION CITY AVG ANNUAL ANIMAL POPULATION 4340 ESTIMATED RNG INJ DTH/YR 5759 AN I MAL TYPE GF BARN OPERATION TYPE Flush SYSTEMS SYSTEM OPTION SELECTED CITY EXISTING BARN EFFLUENT GRAVITY SEWER 11 S-1 DIGESTER INFLUENT LIFT STATION 1 S-2 DIGESTER EFFLUENT FORCED WATER TRANSFER 1 S-3 WET WELL YES 1 S-4 COVER/RAIN WATER REMOVAL YES 1 S-5 NOT USED S-6 POWER FLUSH YES 2 S-7 SLUDGE REMOVAL YES 1 S-8 EMERGENCY VENT YES 2 S-9 BIOGAS INTERFACE YES 1 DIGESTER PARAMETER VALUE UNITS LENGTH 270 FT WIDTH 140 FT TOP OF DIKE ELEVATION 86.2 FT DEPTH 12 FT BOTTOM ELEVATION 74.2 FT DIKE WIDTH 12 FT INTERIOR SLOPE 3:1 EXTERIOR SLOPE 3:1 OPERATING HEIGHT 10 FT OPERATING ELEVATION 84.2 FT LOW DIGESTER OPERATING HEIGHT N/A FT LOW DIGESTER OPERATING ELEVATION N/A FT OPERATING VOLUME 1693998 GAL TOTAL VOLUME 2223473 GAL CUT 5504 CY FILL 5504 CY NET 0 CY SERVICE _ ± BARN EFFLUENT (GRAVITY) AREA 1000 PRICE FARMS 27101 LOCATION DETA LBAGGETT4317 9/20/2024 2:54:43 PM C:\VAULT\PROJECTS\MONARCH BIO ENERGY\REGISTER NC\CADD\01 RA270\ORTHOS\DWGS\00 GENERAL ARRANGEM IL N TRUE NORTH 00 I HEREBY CERTIFY THAT THIS potI I / ENGINEERING DOCUMENT WAS PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AT I AM A DULY LICENSED McC L U RE TM P ODFESS ONAL ENGINEER UNDER making lives better THE LAWS OF THE STATE OF NORTH CAROLINA. 2001 W. BROADWAY, COLUMBIA MO 65203 573-814-1568 MY LICENSE NUMBER IS 101.DWG INC CERTIFICATE OF AUTHORITY C-4628 LICENSE -NO EXISTING BARN EFFLUENT (FORCED) LIFT STATION OVERFLOW .. DIGESTER INFLUENT (FORCED) DIGESTER INFLUENT (FORCED) DIGESTER INFLUENT CLEANOUT *' DIGESTER EFFLUENT (FORCED) WATER TRANSFER WET WELL LATERAL DIGESTER EFFLUENT (GRAVITY) WET WELL LATERAL COVER WATER SUCTION COVER WATER DISCHARGE POWER FLUSH SLUDGE REMOVAL MIXING SUCTION MIXING DISCHARGE ``� N..•CA•������ `� �'• FESS,, O �� 1 • • • 'SE _ i 6059 =!f �J` v (j ��� N �I� C!i �'*•�'��` \�`�� — 09/2- SCALE 1 - ' " 100 SIZE E MILLIMETERS: - .xx -+0.10 xxx =±0.010 ANGLES =±0.5' DIMENSION TOLERANCE (UNLESS OTHERWISE SPECIFIED) A 09JULY24 ISSUED FOR PERMITTING REVISION DESCRIPTION LMB ZTS JE REV # DATE DRWN BY CHK'D BY APP'D BY FRACTIONS: MACHINED PARTS =±1/64 HOLE LOCATIONS ON =±1/32 WELDED ASSEMBLIES LINEAR DIMENSIONS ON =±1/16 STRUCTURAL WELDMENTS ANGLES =±1 ° INCHES: .X =±.020 .XX =±.010 XXX =±.005 XXXX =±.0002 ANGLES =±.05' THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC AND IS PROTECTED UNDER STATE AND FEDERAL LAW, INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et seq. ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC RESERVES ALL PATENT, COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC. ANY USE OF THE INFORMATION CONTAINED IN THIS DOCUMENT STRICTLY PROHIBITOTHER THAN BY THE AUTHORIZED ED. UPON HE REQUEST OF ROESLEINENT FOR THE EXPRASSOCIATES, INC. AND ROESS SLEIN ASE OR WHICH IT HAS BEEN ALTERNATIVE ENERGY, LLC THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIES THEREOF IN ITS POSSESSION. ©2023 ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC D O NOT SCALE PRINT ,j,: SIZE 1211 N/A 1211 611 1211 X" 611 1211 1211 N/A 311 311 611 1211 811 611 MONARCH BIO ENERGY KENANSVILLE, NC AREA 1000 PRICE FARMS NEW DIGESTER LAYOUT SPECIFICATION I CITY PL01 450 N/A N/A H P01 100 HP02 850 HP02 N/A PL01 N/A HP02 700 H P01 50 H P01 150 N/A N/A H P01 80 HP02 200 H P02 100 H P02 50 H P02 50 HP02 305 UNITS FT N/A FT FT FT EA FT FT FT FT FT FT FT FT FT FT ENGINEERS * MANUFACTURERS * CONSTRUCTORS DWG. SHEET REV NO. RA270- 00-27101 4OF6 A 120 120 110 110 100 RIM: 87.75 100 (27601 B) RIM: 85.60 LEVEL ONTROL 90 FF:88.0 FF:88.25 FF:88.25 LIFT STATION WET WELL 90 PIT:88.00 PIT:88.00 PIT:88.25 FF:88.0 (SEE DETAIL) TOB: 84.60 HDPE COVER (SEE DETAIL) PIT:87.25 EXISTING LAGOON RIM:81.25 PROPOSED OUTLET: (27601 B) FB: 85.00 _ DIGESTER 82.60 (LC-2) - LIFT STATION TOB: 80.00 - FF:83.0 FF:83.0 FF:82.75 EE DETAIL) OL: 82.60 FLOATING PUMP PIT:81.50 PIT:81.25 PIT:80.75 INV: 80.85 EXISTING 80 BOTTOM: �� INV:80.60 LEVEL 12�� LEVEL LAGOBOTTOM: (27601O-FB:79.00 80 77.75 CONTROL 77.60 CONTROL PIPE (LC-1) BOTTOM: 75.50 0.5% MIN. PIPE INV: 78.00 0 25°/(MAN) BOTTOM: BOTTOM: 72.60 S H WT: 73.00 - - 71.25 - 70 BOTTOM: 67.00 70 WATER TRANSFER 60 60 NOTE: INVERTS OF EXISTING GRAVITY PIPING ARE APPROXIMATED BASED ON BEST AVAILABLE SURVEY INFORMATION. LEGEND: TOB: TOP OF BANK ELEVATION FF: FINISHED FLOOR ELEVATION FB: FREEBOARD ELEVATION EG: EXISTING GRADE ELEVATION OL: OPERATING LEVEL ELEVATION INV: INVERT ELEVATION SHWT: SEASONAL HIGH WATER TABLE LIQUID FLOW DIRECTION CHAMILTON 9/27/2024 4:18:52 PM P:\200599\06-DRAWINGS\CIVIL\A1 K\REGISTER-CLUSTER 3\AFO PERMIT DRAWINGS\27101 PRICE FARMS AFO PERMIT.DWG EXCAVATION SPECIFICATIONS 1. PROTECTION OF PERSONS AND PROPERTY 1 .1. THE CONTRACTOR SHALL PROTECT STRUCTURES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING, WASHOUT AND OTHER HAZARDS CREATED BY EARTHWORK OPERATIONS. 1.2. ANY SETTLEMENT IN BACKFILL FILL OR IN STRUCTURES BUILT OVER THE BACKFILL OF FILL, WILL BE CONSIDERED TO BE CAUSED BY IMPROPER COMPACTION METHODS AND SHALL BE CORRECTED AT THE CONTRACTOR'S SOLE EXPENSE. ALSO, ANY STRUCTURES DAMAGED BY SETTLEMENT SHALL BE RESTORED TO THEIR ORIGINAL CONDITION BY THE CONTRACTOR AT HIS SOLE EXPENSE. 2. DEWATERING 2.1. PUMPING EQUIPMENT SHALL BE PROVIDED AND EMPLOYED TO PREVENT RAINFALL AND SURFACE RUNOFF FROM ACCUMULATING OR FLOWING INTO EXCAVATIONS AND FROM FLOODING THE PROJECT SITE AND SURROUNDING AREA. PROVIDE AND MAINTAIN PUMPS, SUMPS, SUCTION AND DISCHARGE LINES, AND OTHER DEWATERING SYSTEM COMPONENTS NECESSARY TO CONVEY WATER AWAY FROM THE EXCAVATIONS. THE DISPOSAL OF CONVEYED. WATER SHALL BE DIVERTED IN SUCH A MANNER THAT NATURAL DRAINAGE OF THE AREA SHALL NOT BE DISTURBED. 3. SOIL EROSION 3.1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREVENTION OF SOIL EROSION DURING CONSTRUCTION TO THE MAXIMUM EXTENT POSSIBLE TO COMPLY WITH ALL APPLICABLE NORTH CAROLINA SOIL EROSION LAWS AND REGULATIONS. THE CONTRACTOR WILL ERECT EROSION CONTROL MEASURES IN ACCORDANCE WITH THE APPROVED EROSION CONTROL PLAN, PRIOR TO COMMENCING LAND DISTURBING ACTIVITY. 4. STRIPPING 4.1. ALL VEGETATION SUCH AS BRUSH, HEAVY SODS. HEAVY GROWTH OF GRASS, DECAYED VEGETABLE MATTER, RUBBISH AND ANY OTHER UNSUITABLE MATERIAL WITHIN THE EXISTING PROJECT SITE SHALL BE STRIPPED OR OTHERWISE REMOVED PRIOR TO THE PLACEMENT OF EMBANKMENT. 5. EXCAVATION AND EMBANKMENT FOR SITE FEATURES 5.1. THE ROUGH EXCAVATION SHALL BE CARRIED TO THE NECESSARY DEPTH AS SHOWN ON THE PLANS, TO THE LINES, GRADES AND ELEVATION SHOWN OR AS DIRECTED BY THE ENGINEER, AND SHALL BE MADE SO THAT THE REQUIREMENTS FOR FORMATION OF EMBANKMENTS CAN BE FOLLOWED. ON EMBANKMENT, THE DEPTH OF SUBGRADE DENSIFICATION SHALL BE AS SHOWN ON THE PLANS. SHOULD THE CONTRACTOR, THROUGH NEGLIGENCE OR OTHER FAULT, EXCAVATE BELOW THE DESIGNATED LINES, HE SHALL REPLACE THE EXCAVATION WITH APPROVED MATERIALS, IN AN APPROVED MANNER AND CONDITION, AT HIS OWN EXPENSE. CONTROL OVER THE EXCAVATION. MOVING, PLACING AND DISPOSITION OF ALL MATERIAL AND SHALL DETERMINE THE SUITABILITY OF MATERIAL TO BE PLACED IN EMBANKMENTS. ALL MATERIAL DETERMINED UNSUITABLE SHALL BE DISPOSED OF IN WASTE AREAS OR AS DIRECTED AND SHALL BE REPLACED WITH SELECT MATERIALS DEEMED SUITABLE BY THE ENGINEER. TOPSOIL SHALL NOT BE USED IN SUBGRADES BUT SHALL BE HANDLED AND PLACED AS DIRECTED. SHOULD EXCESS MOISTURE BE ENCOUNTERED DURING EXCAVATION IN THE CONSTRUCTION AREAS, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PERFORM ANY NECESSARY DEWATERING OF THE SITE IN ORDER TO PROVIDE A STABLE EXCAVATED AREA FOR THE PLACEMENT OF EMBANKMENT. THE ENGINEER RESERVES THE RIGHT TO MAKE MINOR ADJUSTMENTS OR REVISIONS IN LINES OR GRADES, IF FOUND NECESSARY. AS THE WORK PROGRESSES DUE TO DISCREPANCIES IN THE PLANS OR TO OBTAIN SATISFACTORY CONSTRUCTION. 5.2. STONES OR ROCK FRAGMENTS LARGER THAN 2" IN THE GREATEST DIMENSION WILL NOT BE PERMITTED IN THE TOP 5" OF THE SUBGRADE. 6. FORMATION OF EMBANKMENTS 6.1. EMBANKMENTS SHALL BE FORMED OF SATISFACTORY MATERIALS PLACED IN SUCCESSIVE HORIZONTAL LAYERS OF NOT MORE THAN 6" IN COMPACTED DEPTH FOR THE FULL WIDTH OF THE CROSS SECTION. THE GRADING OPERATIONS SHALL BE CONDUCTED. AND THE VARIOUS SOIL STRATA SHALL BE PLACED, TO PRODUCE A SOIL STRUCTURE AS SHOWN ON THE TYPICAL CROSS SECTION OR AS DIRECTED. ALL MATERIALS ENTERING THE EMBANKMENT SHALL BE REASONABLY FREE OF ORGANIC MATTER SUCH AS LEAVES, GRASS, ROOTS, AND ANY OTHER OBJECTIONABLE MATERIAL. 6.2. OPERATIONS ON EARTHWORK SHALL BE SUSPENDED AT ANY TIME WHEN SATISFACTORY RESULTS CANNOT BE OBTAINED BECAUSE OF RAIN, FREEZING WEATHER. OR OTHER UNSATISFACTORY CONDITIONS IN THE FIELD. THE CONTRACTOR SHALL DRAG, BLADE OR SLOPE THE EMBANKMENT TO PROVIDE PROPER SURFACE DRAINAGE AT ALL TIMES. 6.3. THE MATERIAL IN THE LAYERS SHALL BE OF PROPER MOISTURE CONTENT BEFORE ROLLING TO OBTAIN THE PRESCRIBED COMPACTION. WETTING OR DRYING OF THE MATERIAL AND MANIPULATION WHEN NECESSARY TO SECURE A UNIFORM MOISTURE CONTENT THROUGHOUT THE LAYER SHALL BE REQUIRED. SHOULD THE MATERIAL BE TOO WET TO PERMIT PROPER COMPACTION OR ROLLING, ALL WORK ON ALL PORTIONS OF THE EMBANKMENT THUS AFFECTED SHALL BE DELAYED UNTIL THE MATERIAL HAS BEEN DRIED TO THE PROPER MOISTURE CONTENT. SPRINKLING SHALL BE DONE WITH APPROVED EQUIPMENT THAT WILL SUFFICIENTLY DISTRIBUTE THE WATER. SUFFICIENT EQUIPMENT TO FURNISH THE REQUIRED WATER SHALL BE AVAILABLE AT ALL TIMES. 6.4. THE EMBANKMENT SHALL BE COMPACTED TO NOT LESS THAN 95% OF THE MAXIMUM STANDARD PROCTOR DENSITY AT OPTIMUM MOISTURE. DURING CONSTRUCTION OF THE EMBANKMENT, THE CONTRACTOR SHALL ROUTE HIS EQUIPMENT AT ALL TIMES, BOTH WHEN LOADED AND WHEN EMPTY, OVER THE LAYERS AS THEY ARE PLACED AND SHALL DISTRIBUTE THE TRAVEL EVENLY OVER THE ENTIRE WIDTH OF THE EMBANKMENT. CARE SHALL BE TAKEN. HOWEVER, NOT TO OVERLOAD THE EMBANKMENT AREA WITH CONSTRUCTION EQUIPMENT. 6.5. IN THE CONSTRUCTION OF EMBANKMENTS, STARTING LAYERS SHALL BE PLACED IN THE DEEPEST PORTION OF THE FILL; AS PLACEMENT PROGRESSES, LAYERS SHALL BE CONSTRUCTED APPROXIMATELY PARALLEL TO THE FINISHED PAVEMENT GRADE LINE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF ALL EMBANKMENTS MADE UNDER THE CONTRACT AND SHALL REPLACE ANY PORTION WHICH, IN THE OPINION OF THE ENGINEER. HAS BECOME DISPLACED DUE TO CARELESSNESS OR NEGLIGENCE ON THE PART OF THE CONTRACTOR. 7. TESTING 7.1. THE OWNER WILL PROVIDE THE SERVICES OF AN INDEPENDENT SOILS TESTING FIRM FOR PERFORMING TESTS AS ARE REQUIRED TO IDENTIFY MATERIALS, TO DETERMINE COMPACTION CHARACTERISTICS,TO DETERMINE MOISTURE CONTENT, AND TO DETERMINE DENSITY OF FILL IN PLACE. THESE TESTS PERFORMED WILL BE USED TO VERIFY THAT THE FILLS CONFORM TO THE REQUIREMENTS OF THE SPECIFICATIONS. TEMPORARY SEEDING CHART SPECIES PLANTING DATES LBS/ACRE CEREALS: RYE/WHEAT 8/15-12/30 120 MILLETS/SUDANGRASS 4/15-8/15 40 ANNUAL LESPEDEZA 12/1-4/15 50 1. FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. 2. APPLY 4,000 .B/ARE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. 3. IF GROWTH IS LESS THAN FULLY ADEQUATE, REFERTILIZE IN THE SECOND YEAR ACCORDING TO SOIL TESTS OR TOPDRESS WITH 500 LB/ARE 10-10-10 FERTILIZER, RESEED, REFERTILIZE, AND MULCH AREA IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. IF SEEDING IN FALL, TOPDRESS WITH 50 LB/ACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 LB/ACRE LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. PERMANENT SEEDING CHART SPECIES PLANTING DATES LBS/ACRE COMMON BERMUDAGRASS 4/1-7/15 10 MILLETS/SUDANGRASS 4/1-7/15 10 ANNUAL LESPEDEZA 4/1-7/15 30 1. APPLY LIME AND FERTILIZER ACCRODING TO SOIL TESTS, OR APPLY 3,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 500 LB/ACRE 10-10-10 FERTILIZER. 2. APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR BY TACKING WITH ASPHALT, ROVING, NETTING, OR CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. 3. REFERTILIZE THE FOLLOWINGN APRIL WITH 50 LB/ACRE OF NITROGEN. REPEAT AS GROWTH REQUIRES. MAY BE MOWED ONLY ONCE A YEAR. WHERE A NEAT APPEARANCE IS DESIRED, OMIT LESPEDEZA AND MOW AS OFTEN AS NEEDED. STABILIZATION TIMEFRAME CHART SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS PRIMETER DIKES, SWALES, DITCHES, SLOPES 7 DAYS NONE SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES > 50' IN LENGTH ALL OTHER AREAS WITH SLOPES < 4:1 14 DAYS NONE POST 4'-0" MIN. 10' MIN. FENCE 4" MIN. WIDTH TRENCH & COMPACTED BACKFILL v o 6" Min �o v o v v GEOTEXTILE FILTER FABRIC SECTION A -A ATE TYPICAL SECTION 1. A STABILIZED PAD OF CRUSHED STONE SHALL BE LOCATED WHERE TRAFFIC WOOD POST (TYP) NOTES: WILL BE ENTERING OR LEAVING A CONSTRUCTION SITE OR FROM A PUBLIC STREET. FENCE 1. MINIMUM LONGITUDINAL SPLICE FABRIC 5' SPACING MAX OVERLAP SHALL BE 2' WITH A 2. STONE TO BE 2-3 INCH WASHED STONE (SURGE STONE) POST AT EACH END. SECURE FABRIC TO POSTS. 3. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT 2. SUPPORT FENCE REQUIRED TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC STREETS OR EXISTING GROUND z WITH SILT FENCE AROUND LINE g z DROP INLET OR WHEN USED PAVEMENT. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL ACROSS DITCH. STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY Lo 3. INSTALL AROUND INLETS AND MEASURES USED TO TRAP SEDIMENT. ADDITIONAL CUT AREAS. 4. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. TRENCH GROUND 5. WHEN NECESSARY, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT BOTTOM LINE TRENCH PRIOR TO ENTERING A PUBLIC STREET. WHEN WASHING IS REQUIRED, IT BOTTOM SHALL BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN. GENERAL NOTES: 6. FILTER FABRIC SHALL BE MIRAFI 500 OR EQUAL. 1. FENCE FABRIC SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A MINIMUM OF 6 LINE WIRES WITH 12" STAY SPACING. ('_�2DETAIL-CONSTRUCTION ENTRANCE 2. FILTER FABRIC SHALL BE MIRAFI 100 FABRIC OR EQUIVALENT. BURLAP CANNOT BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD MORE N.T.S. THAN 30 DAYS. MAINTENANCE NOTES: 1. FILTER BARRIERS SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY. 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL BE NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH STORM EVENT. THEY MUST BE REMOVED WHEN DEPOSITS REACH APPROXIMATELY 0.5 FT. IN DEPTH. 4. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE OR FILTER BARRIER IS NO LONGER REQUIRED SHALL BE DRESSED TO CONFORM WITH THE EXISTING GRADE, PREPARED AND SEEDED. 5. PROVIDE OUTLETS WITH SEDIMENT FENCE AT LOW SPOTS FOR DEWATERING LARGE AREAS (USE CLASS B STONE). DETAIL -SILT FENCE 27� 0� N.T.S. EROSION AND MAINTENANCE CONTROL SCHEDULE: 1. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NECESSARY REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN THE INTEGRITY OF ALL SUCH DEVICES. 2. ALL TEMPORARY/PERMANENT BASINS AND ROCK CHECK DAMS SHALL BE CLEANED OUT AND RESTORED TO ORIGINAL VOLUME WHEN THE SEDIMENT ACCUMULATES TO APPROXIMATELY ONE HALF OF THE DESIGN VOLUME. GRAVEL SHALL BE CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS. 3. SEDIMENT SHALL BE REMOVED FROM BEHIND THE SEDIMENT FENCE AND AT THE INLET PROTECTION SEDIMENT FENCE WHEN IT BECOMES APPROXIMATELY 6" DEEP AT THE FENCE. THE SEDIMENT FENCE SHALL BE REPAIRED AS NECESSARY TO PRESERVE THE INTEGRITY OF THE FENCE. 4. ALL SEEDED AREAS SHALL BE FERTILIZED. RESEEDED AND MULCHED AS NECESSARY TO ESTABLISH A VIGOROUS, DENSE VEGETATIVE COVER. COIL FIBER ROLLS TO BE CHECKED FOR INTEGRITY AND BE REPLACED OR REPAIRED AS NECESSARY AFTER EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NECESSARY REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN THE INTEGRITY OF ALL SUCH DEVICES. CHANNEL GRADE G 5' MIN 4" DIA. RIP RAP 2.5:1 MAX 1 FT THICK 1/2"-3/4" GRAVELLAYER 2.5:1 MAX & MAX. DETAIL -TEMPORARY ROCK CHECK N.T.S. AMILTON 9/27/2024 4:18:56 PM P:\200599\06-DRAWINGS\CIVIL\A1 K\REGISTER-CLUSTER 3\AFO PERMIT DRAWINGS\27101 PRICE FARMS AFO PERMIT.DWG TOP OF BERM HIGH PUMP OPERATING HEIGHT 0 N l 1 12" WET WELL LATERAL LAGOON OPERATING LEVELS II[GANTIlIl►VAI?i WET WELL LATERAL CENTER OF PIPE TOP OF SLUDGE BOTTOM OF LAGOON SPIROS1623 3/5/2024 4:16:25 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-251-2.DWG ISE�C _ n k6059 srr% 09/27/2024 KinTF.q- 80-MIL HDPE FLOATING COVER 0 M 60-MIL HDPE LINER COMPACT THE BOTTOM SOIL. ANCHOR TRENCH PLAN VIEW NOTE 1 PERIMETER PIPING NOTE 2 WELD COVER/LINER HERE 1. PERIMETER PIPING. SEE RA-STD-254 FOR DETAILS. 2. NO TRENCH; EXCAVATE FROM TURNDOWN OF LINER/COVER; BACK FILL AND COMPACT IN STAGES TO COVER LINER/COVER. SSPIROS1623 5/3/2024 3:22:16 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\COVER DRAWINGS\DWG FILES\RA-STD-253-2.DWG ISE�C _ n k6059 srr% 09/27/2024 NOTES: DAYLIGHT OUT BERM SPIROS1623 6/20/2024 1:35:36 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\COVER DRAWINGS\DWG FILES\RA-STD-255-2.DWG LAGOON EMERGENCY VENT PORT ELEVATION VIEW SS ��i Q ! z IISE i i 056059 �K�`` 09/27/2024 2 1. TWO EMERGENCY VENTS REQUIRED PER LAGOON, ONE AT EACH END OF THE LAGOON FURTHEST FROM THE BARNS. NOTES: 1. 45' HOSE LENGTH IS BASED ON RAINWATER PUMP BEING CENTERED WITH THE CUSTOM STRAINER SEE DETAIL "F" HDPE STRAPS. SEE DETAIL "C" FLEXIBLE HOSE. SEE DETAIL "A" NOTE 5 `- BALLAST PIPING C1l 55' 55' -J --�-- 30' COVER ANCHOR STRAPS CUSTOM STRAINER SEE DETAIL "E" SEE DETAIL "F" COVER RAINWATER REMOVAL SUCTION PIPE PLAN VIEW 1.)nl A DETAIL A: FLEX HOSE INSTALLATION NOTE 4 MALE CAMLOCKS NOTE 2 3"SDR 17 10' DETAIL E: COVER ANCHOR STRAPS FLEXIBLE HOSE. SEE DETAIL "B" RAINWATER REMOVAL PUMP SEE DETAIL "D" FOR PIPE ORIENTATION APRON (NOTE 3) APRON (NOTE MALE CAMLOCKS 3" SDR 17 NOTE 2 STD256- DISTANCE BETWEEN STRAP WELDS = 24" 42" DETAIL C: FLEX HOSE ANCHOR STRAPS L/\ 11AuJIlJIV VVC.LLjF-L.! I V r1rRlJIV IIVLi I L J). SEE DETAIL "C". DETAIL B: FLEX HOSE INSTALLATION NOTE 4 APRON (NOTE 3) NC 6" U/'1LLFiJ I ririivv. STD�256-2 FLOATING COVER FLOATING COVER AND BEING 10' FROM THE EDGE OF THE COVER. CALCULATIONS ARE REQUIRED IF RAINWATER PUMP LOCATION DIFFERS. 2. WHEN INSTALLING, ENSURE THAT TRANSITION PIECES/CAMLOCKS WILL NOT TEAR COVER. 3. HDPE STRAPS & APRON SHALL BE SAME THICKNESS AS COVER MATERIAL. 4. SEE RA-STD-293 FOR RAINWATER FLEX HOSE ASSEMBLY DETAILS. 5. SEE RA-STD-257 FOR BALLAST PIPE DETAILS. FEMALE CAMLOCKS rn\ir-:Q PUMP SUCTION PIPE (3" SDR 17) ING COVER SPIROS1623 6/26/2024 9:00:04 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\COVER DRAWINGS\DWG FILES\RA-STD-256-2.DWG ISE�C n k6059 srn= 09/27/2024 NnTF.q- SSPIROS1623 HIGH EFFLUENT LOW EFFLUENT FLOATING COVER 0 2 W_ NOTE 4 NOTE 5 2°/Q SLOPE BOTTOM OF TEE MUST BE ABOVE LAGOON HIGH WATER LEVEL 5 ~1 NOTE 5 I NOTE 6 5 NOTE 3 BIOGAS DRAW -OFF INSTALLATION ELEVATION VIEW 6/13/2024 12:18:26 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\COVER DRAWINGS\DWG FILES\RA-STD-261-1.DWG 0:: Ovallm NO POCKETS 1� 1 3 NOTE 1 3 NOTES 7, 8, 9, 10 8" PERIMETER PIPING 1. SEE RA-STD-276 FOR BLOWER SKID ASSEMBLY DETAILS. 2. ELEVATION TO CHANGE WITH TOPOGRAPHY. 3. SEE DRAWING RA-STD-253 FOR ANCHOR TRENCH DETAILS. 4. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 5. 5. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 6. COVER CONTRACTOR TO SUPPLY MANUFACTURED BOOT. 7. SEE PIPING ALIGNMENT DRAWINGS FOR STUB UP LOCATION. 3. VALVE SHALL BE INSTALLED PRIOR TO COVER INSTALLATION. 3 9. BUTTERFLY VALVES SHALL BE INSTALLED IN THE OPEN POSITION AND TURNED CLOSED AFTER INSTALLATION. 10. BOLTS AT TOP OF BUTTERFLY VALVE CONNECTING TO ABOVE GRADE PIPING IS TO BE SUPPLIED BY ROESLEIN. )VER , 8" LINE TO ABOVE GRADE DRAW OFF 4" DRAIN LINE TO LAGOON 8" INVERTED TEE IN LINE WITH PERIMETER PIPING _ 611 w ry IY O _ U z Q LL O w w 0 0 — — — — — — — — ' BOTTOM OF ANCHOR TRENCH DETAIL A: BIOGAS EXTRACTION POINT SECTION VIEW 3 BILL OF MATERIALS TAG DESCRIPTION SPEC SIZE QTY 1 PIPE HP01 811 VARIES 2 PIPE HP01 411 20' 3 90 ELBOW HP01 8" 1 4 ECCENTRIC REDUCER HP01 8" x 4" 1 5 TEE HP01 8" 2 6 FLANGE ADAPTER HP01 8" 1 7 BACKUP RING HP01 811 1 8 MACHINE BOLT HP01 3/4" x 3" 8 9 BUTTERFLY VALVE BUF05 811 1 10 22.5 ELBOW HP01 411 1 0III��lift1 / o�°N CA Q����i , 3 24FEB24 ADDED NOTE 10, REVISED BOLT SIZE CBE SJS CBE KPL 2 28JUN23 UPDATED BILL OF MATERIALS CBE SJS KPL CD SCALE slzE E MILLIMETERS: ROESLEIN &ASSOCIATES INC. ••"�•�**•''•. ��i �'.•'�FESS � i� 1 25MAY23 ISSUED FOR CONSTRUCTION CBE SJS KPL CD DIMENSION TOLERANCE x xx =±O.1 =±a10 , v �i�i 0 03APR23 ISSUED FOR CONSTRUCTION CBE SJS KPL CD (UNLESS OTHERWISE SPECIFIED) ANGLES ANGLES =±0.010 =±0.5° RN G PIPING STANDARD RO E S L E �T • 'SE _ _ REV DRWN CHK'D APP'D DATE REVISION DESCRIPTION BY # By BY By THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY FRACTIONS: INCHES: AREA OOO TM — 6059 S � �� INFORMATION THAT IS THE PROPERTY OF ROESLEIN &ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, MACHINED PARTS =±1/64 X =±.020 A' !. ��� INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et seq. ROESLEIN & ASSOCIATES, INC. RESERVES ALL PATIENT, COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, HOLE LOCATIONS ON -+-1/32 WELDED ASSEMBLIES XX _ -+ 010 =±.005 BIOGAS DRAW —OFF 'Y ` V N ` ��`` USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE OR IN OR IN WITHOUT THE EXPRESS ITTEN PERMISSION RN LINEAR DIMENSIONS ON =±1/16 _XXX .XXXX =±.0002 ENGINEERS •MANUFACTURERS •CONSTRUCTORS C •.••.••LICATED I L NOLE ASSOCIATES, INC.. ANY USE OF THE INFORMATIOCONTAINED THIS DOCUMENT OTHER THAN BY THE AUTHORIZOED RECIPIENT FOR THE EXPRESS PURPOSE FOR WHICH IT HAS BEEN PROVIDED IS STRICTLY PROHIBITED. UPON THE REQUEST OF ROESLEIN & STRUCTURAL WELDMENTS ANGLES =±1 ' ANGLES =±.05° INSTALLATION DETAILS DWG. SHEET REV ��ii1i"��� ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL RA-STD-261-1 OF 1 1 3 09/1 COPIES THEREOF IN ITS POSSESSION. ©2019 ROESLEIN &ASSOCIATES, INC. D O NOT SCALE PRINT N O . NnTF.q- OPERATING WATER LEVEL r 1 3 NOTE 2 Ala ------ NOTE 1 1 GRAVITY TRANSFER WATER WET WELL INSTALLATION DETAIL ELEVATION VIEW �rrL 0.5% MIN 0 n �I NOTE 4 NOTE 5 0 A NOTE 6 6'-0" CONDENSATE FRETURN LINE a n 3 . . . 1. SEE RA-STD-253 FOR ANCHOR TRENCH INSTALLATION DETAILS. 2. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 3. 3. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 4. SEE RA-STD-272 FOR WET WELL HOUSING AND PIPING DETAILS. 5. SEE RA-STD-273 FOR PRECAST WET WELL DETAILS. 6. SEE RA-STD-274-2 FOR WET WELL LEVEL INDICATOR DETAILS. 0.5% MIN 1 EXISTING OPEN LAGOON SSPIROS1623 6/25/2024 1:50:41 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-262-3.DWG ISE�C _ n k6059 srr% 09/27/2024 NnTF.q- r 19 E 18 20 11 1 14 17 15 16 m ----- 13 0,:":":w 10) (7 FLOATING PUMP DISCHARGE INSTALLATION PLAN VIEW NOTE 4 7 FLOATING PUMP DISCHARGE INSTALLATION ELEVATION VIEW co w O z 1. ATTACH TO FLOATING PUMP ASSEMBLY. 2. VARIES, SEE ALIGNMENT DRAWINGS. 3. DEPTH AS REQUIRED BY PIPING ALIGNMENT DRAWINGS. 4. VALVE BOX LOCATION TO BE DETERMINED BY THE FARM OPERATOR. 5. SEE RA-STD-237 FOR VALVE BOX INSTALLATION DETAILS. / c JJ F1 In W LLI IL L r NOTE 5 HDPE SDR 11 WATER MANAGEMENT PIPING It NOTE 2 SSPIROS1623 3/6/2024 4:55:11 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-263-1.DWG ISE�C 0 6059 8rn= 09/27/2024 O O O O Oo0o0o0oC`r I I i t i t Li LL f000000�roo�� FLOATING PUMP DISCHARGE INSTALLATION 18) �20) (11 14 17 15 19 16 9 m 13 7 U NOTE 1 0 0 0 0 5 4 3 2 21-� 22 M W H O z 7 3 FLOATING PUMP DISCHARGE INSTALLATION SSPIROS1623 3/7/2024 10:46:57 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-263-3.DWG 1 SAS ' NL IISE ; i M6059 ( = �����//• 1111111����` 09/27/2024 7 HDPE SDR 11 WATER MANAGEMENT PIPING NOTE 2 NOTES: 1. ATTACH TO FLOATING PUMP ASSEMBLY. 2. VARIES, SEE ALIGNMENT DRAWINGS. 3. DEPTH AS REQUIRED BY PIPING ALIGNMENT DRAWINGS. A I f1Tr C%. 3 2 41516 NOTE 2 NOTE 3 NOTE 4 6PIROS1623 3/7/2024 10:38:30 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-264-2.DWG FLOATING COVER 1 IRRIGATION SUCTION PLAN VIEW IRRIGATION SUCTION ELEVATION VIEW SAS �i '� IISE ; i M6059 �����//• 1111110" 09/" NOTE 1, 5 NOTE 6 1. ANCHOR PIPE TO KEEP FROM MOVING. 2. MINIMUM OF 15' FROM THE EDGE OF THE COVER. LOCATION TO BE VERIFIED BY FARM OPERATOR. 3. SEE DRAWING RA-STD-253 FOR ANCHOR TRENCH DETAILS. 4. BENTONITE SLEEVE TO EXTEND BACK FROM THE TOP OF THE PIPE PENETRATION BY AT LEAST 36". ALL BACKFILL PIPE IN TRENCHES SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. BENTONITE SEAL MINIMUM 6" AROUND THE FULL DIAMETER OF THE PIPE. BENTONITE SEAL TO EXTEND FULL WIDTH OF THE TRENCH. 5. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 4. 6. TOP OF PIPE NEEDS TO END 2' BELOW THE LOW EFFLUENT. SEE RA-STD-251 FOR OPERATING LEVELS. HIGH EFFLUENT LOW EFFLUENT NnTF.q- c� . SEWER CLEANOUT NOTE I IIIII NOTE I IIIII 2 X 3 1 4 � 5 0 0 N SEWER LINE NOTE 1 TOP OF BERM SSPIROS1623 12/7/2023 10:08:15 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-266.DWG POWER FLUSH PLAN VIEW FLOATING COVER NOTE 3 1 z 3 N if NOTE 5 1 POWER FLUSH ELEVATION VIEW 1 „ 1111111 O'''' 011 ��••••••••• 'I ����-��•FESS; '•• C/'�i� Q �"y • ISE _ — • 6059 S V► = A' !. �� 'Y V � %x ''��.,'� •••••••�� \;```� C jv \\ Li1i"��V� 09/27/2024 SCALE slzE E MILLIMETERS: .X —±0.5 .xx =±o.10 xxx=±0.010 ANGLES =±0.5° 1 28JUN23 UPDATED BILL OF MATERIALS CBE SJS KPL MDC DIMENSION TOLERANCE (UNLESS OTHERWISE SPECIFIED) 0 08JUN23 ISSUED FOR CONSTRUCTION CBE SJS KPL MDC REV DATE REVISION DESCRIPTION BY DRWN BY CHK'D BY APP'D BY FRACTIONS: MACHINED PARTS =±1/64 HOLE LOCATIONS ON =±1/32 WELDED ASSEMBLIES LINEAR DIMENSIONS ON =±1/16 MENTS STRUCTURAL WELD ANGLES =±1° INCHES: X =±,020 XX =±.010 XXX =±.005 XXXX=±,0002 ANGLES =±.05° THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et se ROESLEIN & ASSOCIATES, INC. RESERVES ALL PATIENT, Q COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & ORASSOTHIATES, INC.. ANY USE OF THE E EXPRESS PURPOSE FOR WHICHRITAHAS BEEN PROVIDED S STRICTLY PROHIBATION CONTAINED IN THIS DOCUMENT ITED. ED. UPON THE REQUEST ER THAN BY THE RIZED RECIPIENTOF ROESLEIN & ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIESTHEREOFASSOCIATES, ©2019 ROESLEIN &ASSOCIATES, INC. /� DO NOT SCALE J f� PRINT 1. REFER TO FARM OPERATOR FOR EXACT LOCATION. 2. 6" POWER FLUSH INSTALLED APPROXIMATELY 18" ADJACENT TO SEWER LINE CLEANOUT. SEE RA-STD-265 FOR DETAILS. 3. SEE DRAWING RA-STD-253 FOR ANCHOR TRENCH DETAILS. 4. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 5. 5. A BENTONITE SLEEVE, 611 MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. HIGH PUMP LOW PUMP LOW LAGOON NOTE 4 1 BILL OF MATERIALS TAG DESCRIPTION SPEC SIZE QTY 1 PIPE FLANGE ADAPTER HP02 6" 609 2 HP02 6" 1 3 BACKUP RING HP02 6" 1 4 GASKET STUD BOLTS W/ NUTS HP02 6" 1 8 5 HP02 3/4" x 4%4" LG 6 BLIND FLANGE HP02 6" 1 ROESLEIN & ASSOCIATES, INC. ' - RNG PIPING STANDARD ROESLEIN. AREA 1000 POWER FLUSH ENGINEERS • MANUFACTURERS • CONSTRUCTORS INSTALLATION DETAILS DWG. SHEET REV NO. RA-STD-266 1 OF2 1 FOXMiM =1 I HIGH PUMP I LOW PUMP LOW LAGOON SSPIROS1623 FLOATING COVER 1 i 1 3 OFF -SPEC LAGOON TIE IN ELEVATION VIEW 0 2 1 NOTE 2 1 2 U\ V MIN 1 5 C! NOTE 3 0:Q: n. ff": 3 w I- O z TOP OF BERM/GRADE NOTE 4 C `��••••••••• �I ����-��•FESs; '•• C/'�i� OsrQ-� �i�i Q �"y • 'SE _ — • 6059 0 - A, !.� ,Y V � %x ''��.,'� •••••••�� \;```� C N \\ iLi1i"��V 12/7/2023 10:14:21 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-267.DWG 09/� I SCALE SIZE E MILLIMETERS: X =±0.5 xx =±0.10 xxx=±0.010 ANGLES =±0.5° 1 28JUN23 UPDATED BILL OF MATERIALS CBE SJS KPL MDC DIMENSION TOLERANCE (UNLESS OTHERWISE SPECIFIED) 0 08JUN23 ISSUED FOR CONSTRUCTION CBE SJS KPL MDC REV # DATE REVISION DESCRIPTION BY DRWN BY CHK'D BY APP'D BY FRACTIONS: MACHINED PARTS =±1/64 HOLE IEMBLIONS O S =±1/32 WELDED ASSATES, LINEAR DIMENSIONS ON =±1/16 MENTS WELD ANGLES =±1° INCHES: X =±,020 .XX =±.010 .XXX =±.005 XXXX=±.0002 ANGLES =±.05° THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, INC. RESERVES ALL PATIENT, COPYRIGHT AND OTHER IPROPRI PROPRIETARY RIGHTS TOTTHIS ION IDOCUMENT01 et seq. � INCLUDING ALL DESLEIN & IES GN, MANUFACTURING, REPRODUCTION, USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & ORASSOTHIATES, INC.. ANY USE OF THE E EXPRESS PURPOSE FOR WHICHRTnHA3 BEENNTAINED IN THIS PROVIDED S STRIOCTLYIPROHENT OIBHTEDER TUPON THE REQUEHAN BY THE ST OF ROESLEIN & IZED RECIPIENTSTRUCTURAL ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIESTHEREOFIN S OCIATES,INC. ©2019 ROESLEIN &ASSOCIATES, INC. DO NOT SCALE PRINT 1. DEPTH AS REQUIRED BY PIPING ALIGNMENT DRAWINGS. NO SLOPING REQUIREMENT ON INCOMING OFF SPEC GAS LINE. 2. SEE RA-STD-253 FOR ANCHOR TRENCH INSTALLATION DETAILS. 3. BUTTERFLY VALVES SHALL BE INSTALLED IN, 1 THE OPEN POSITION AND TURNED CLOSED AFTER INSTALLATION. 4. SEE PIPING ALIGNMENT DRAWINGS FOR OFF -SPEC PIPE SIZE. 1 BILL OF MATERIALS TAG DESCRIPTION SPEC SIZE QTY 1 PIPE HP01 8" 25' 2 TEE HP01 8" 1 3 REDUCER, ECCENTRIC HP01 8" x 4" 1 4 90 ELBOW HP01 811 5 5 BUTTERFLY VALVE BUF05 811 1 6 FLANGE ADAPTER HP01 811 2 7 BACKUP RING HP01 811 2 8 MACHINE BOLT HP01 3j4° x 3° 16 ROESLEIN & ASSOCIATES, INC. 7"_�A RNG PIPING STANDARD ROESLEIN. AREA 1000 OFF -SPEC CONNECTION ENGINEERS • MANUFACTURERS • CONSTRUCTORS INSTALLATION DETAILS DWG. SHEET REV NO. RA -STD -267 1 OF2 1 NOTFS- HIGH PUMP 1. TOP OF PIPE MUST BE 18" BELOW THE LOW LAGOON LEVEL. 2. SEE DRAWING RA-STD-253 FOR ANCHOR TRENCH DETAILS. 3. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 4. 4. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 5. SEE RA-STD-284 FOR EARTH ANCHOR INSTALLATION DETAILS. 6. DEPTH AS REQUIRED BY PIPING ALIGNMENT DRAWINGS. NOTE 8 FLOATING COVER NOTE 13 TOP OF BERM 3 NOTE 7 X1 :":ffol© 0 13 14 OPERATING HEIGHT _ 1 LOW PUMP I I I NOTE 3 - 1 1 10 12 11 I I C/�IJ I IIVV JCVVLfI LIIVL 1 I 1 NOTE 2 3 1 0 7. VALVE BOX TO BE 2' BACK FROM THE BACK TOE OF THE BERM, APPROXIMATELY 12' FROM THE INNER EDGE OF THE BERM. 8. SEE RA-STD-287 FOR VALVE BOX INSTALLATION DETAILS. 9. COVER CONTRACTOR TO SUPPLY MANUFACTURED BOOT. 10. LOCATION FOR VACUUM BREAKER WHEN REQUIRED. 11. FOR CLAY LINED LAGOONS, SEE RA-STD-284 FOR EARTH ANCHOR INSTALLATION DETAILS. FOR PLASTIC LINED LAGOONS, SEE DETAIL "A". 12. BALLAST PIPE TO HAVE SAME SIZE AS SEWER PIPE. HDPE STRAP WELDED TO BALLAST PIPE AND SEWER PIPE. 13. ADD RUB SHEET TO COVER. 3 SPIROS1623 4/11/2024 2:46:45 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-269.DWG 1 LAGOON FORCED SEWER ELEVATION VIEW 3 SAS �i '� IISE ; i M6059 �����//• 11111M���� 09/" tl off 7f nil cil BEN MINI ARC DIAL PIPE THE OF 1 c u PENETRATION REPAIR PATCH 'PLATE TO SKIRT D PERIMETER 6PIROS1623 12/8/2023 11:52:34 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-270.DWG CA/I171TIAIf- I Irli= EXISTING LINER PENETRATION DETAIL 1. BENTONITE SLEEVE TO EXTEND BACK FROM THE TOP OF THE PIPE PENETRATION BY AT LEAST 36". 2. ALL BACKFILL IN PIPE TRENCHES SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. KinTF.q- L------L BACK TO OPEN LAGOON / WET WELL NOTE 4, 5 TE 2, 3 Cnl IAI Cnl I A I INSTALLED BY UNDERGROUND PIPING CONTRACTOR 27 27 31 31 125 DISCHARGE 4 3 RAINWATER REMOVAL PUMP ELEVATION VIEW NOTE 7 RAINWATER REMOVAL PUMP PLAN VIEW SSPIROS1623 3/6/2024 4:23:02 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-271-3.DWG NOTE 6 17 INSTALLED BY UNDERGROUND PIPING CONTRACTOR F --- I I 16 I I ---------- ------------r--------- 20 I I NOTE 2,3 I I I I I I q I I I I I I GRADE I I � I I L-- - - - - - I TO LOCAL DISCHARGE STATION 1. SEE LOCAL GENERAL ARRANGEMENTS, SUPPORT DETAILS, AND PANEL MOUNTING INFORMATION. 2. ELECTROFUSION COUPLER NEEDED IF DISCHARGE OF PIPE IS LESS THAN 3 FEET ABOVE GRADE. 3. ELECTROFUSION COUPLINGS PROVIDED BY INSTALLING CONTRACTOR. 4. COVER WATER FLOW BACK INTO LAGOON UNDER COVER WHEN WATER TESTS HOT FOR EFFLUENT. 5. SEE RA-STD-260 FOR UNDER COVER RETURN. 6. INSTALL FEMALE CAMLOCK CAP - ITEM 13 ON THE B.O.M. - ON PIPE TO LAND DISCHARGE. 7. SEE RA-STD-293 FOR RAINWATER FLEX HOSE ASSEMBLY DETAILS. 8. BUTTERFLY VALVES SHALL BE INSTALLED IN THE OPEN POSITION AND TURNED CLOSED AFTER INSTALLATION. •�� CaR SS ' ` /���i REV • DATE REVISION DESCRIPTION ISE __ # - � � THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, 6059 S /y�� INFORMATION THAT IS THE PROPERTY OF ROESLEIN &ASSOCIATES, �v. �` USE, AND SALES RIGHTS THERETO THERETO, T TO THE EXTENT SAID RIGHTS ��� /� ` MUST NOT BE DUPLICATED OR DISCLOSED IN WHOLE OR IN PART •' •N• FORASSTHEEXPRESS PURPOSE FOR WHICATES, INC.. ANY USE OF THE H T HASON CONTAINED IN THIS B BEEN PROVIDED IS ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY COPIES THEREOF IN ITS POSSESSION. 09/27/2024 02019 ROESLEIN & ASSOCIATES, INC. BILL OF MATERIALS TAG DESCRIPTION 1 BALL VALVE - BAT02 - CL 800 FNPT 2 WATER HOSE ADAPTER, THREADED MALE OUTLET 3 BALL VALVE, BAT02 - CL800 THREADED 4 PIPE, NIPPLE, SCH 80 CARBON STEEL ERW, GALVANIZED, THREADED ENDS 5 WELD OUTLET, CARBON STEEL, 3000 LB, THREADED FEMALE OUTLET (THREAD-O-LET) 6 FLANGE, THREADED, GALVANIZED CARBON STEEL, 150 LB, RAISED FACE, BORE TO SCH 80 7 GASKET, GARLOCK 3000 NITRILE GASKET OR EQUL, %8" THICK 8 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 9 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 10 LUG BOLT, A193 GR B7 / W(2) ASTM A194 GR 2H HEAVY HEX NUTS TEFLON COATED 11 BUTTERFLY VALVE - BUF02 - CL 150, THREADED 12 FLANGE, 304 SS, RF, CL 150, THREADED 13 CAMLOCK CAP, FEMALE, 304 SS 14 MALE CAMLOCK, 304 SS, THREADED MALE OUTLET 15 FEMALE CAMLOCK, THREADED FEMALE OUTLET, 304SS 16 TRANSITION FITTING, HDPE SDR 17 TO 304 SS (M) NPT 17 MALE CAMLOCK, THREADED FEMALE OUTLET, 304 SS 18 90 ELBOW, HDPE SDR 17, PE4710 ASTM D3261 IPS 19 PIPE, HDPE, PE4710, SDR 17, DIMENSIONS PER ASTM F2619 20 ELECTROFUSION COUPLERS 21 EXTRA NITRITE O-RINGS FOR CAMLOCKS 22 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 23 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 24 90 ELBOW, GALVANIZED MALLEABLE IRON, CL150, THREADED ENDS, SCH 80 25 FLANGE, THREADED, GALVANIZED CARBON STEEL, 150 LB, RAISED FACE, BORE TO SCH 80 26 TYPE A - ALUMINUM CAMLOCK FITTING 27 LUG STUD TEFLON COATED A193 GR B7 / W(2) ASTM A194 GR 2H HEAVY HEX NUTS TEFLON COATED 28 WELD OUTLET, CARBON STEEL, 3000 LB, THREADED FEMALE OUTLET (THREAD-O-LET) 29 PIPE, NIPPLE, CARBON STEEL, GALVANIZED, SCH 80, THREADED ENDS 30 BALL VALVE - BAT02 - CL 800 THREADED 31 GASKET, GARLOCK 3000 NITRILE GASKET OR EQUAL, %8" THICK DRWN CHK'D APP'D BY gv gv gv AND PROPRIETARY UNDER STATE AND FEDERAL LAW, GRANTED OTHERS. THIS DOCUMENT WRITTEN PERMISSION OF ROESLEIN & UPON THE REQUEHAN BY THE ST OF ROES EIZED IENTIN & OR DESTROY THIS DOCUMENT AND ALL SCALE SIZE MILLIMETERS: .XXXX=+_0.010 ANGLES =±0.5° ROESLEIN & ASSOCIATES, INC. R N G PIPING STANDARD r,r,rr,, AREA V V V RAINWATER REMOVAL PUMP PIPING DETAILS (UNLESISOOTHOERW SEE SPECIFIED) FRACTIONS: MACHINED PARTS =±1/64 WELDED ASSIEMBLIO S =±1/32 LINEAR DIMENSIONS ON _+ STRUCTURAL WELD ANGLES =±1/16 ENTSANGLES INCHES: .XX =±,010 .XXX =±.DDS .XXXX 1202 =±.05° CONTAINS CONFIDENTIAL INC. AND IS PROTECTED ARE EXPRESSLY WITHOUT THE EXPRESS STRICUMENT OTHER CTLY Y PROHIBITED. RETURN DO NOT SCALE PRINT SPEC SIZE QTY CS05 1" 1 SP-1006B-XX 3/4" NPT (M) x 3/4" 1 CS05 3/4„ 1 CS05 3/4" x 4" 1 CS05 OUTLET 3/4", HEADER 1%2" 1 CS05 3" 1 CS05 3" 2 CS05 1 " x 4" 1 CS05 3" x 8" 1 CS05 5/8" X 13/4" g CS05 3" 2 CS05 3" 1 S P-1007-A-XX 3" 1 S P-1007 B-XX 3" 1 SP-1007C-XX 3" 2 H P02 3" 3 SP-1007D-XX 3" 2 H P02 3" 2 H P02 3" 10, HP02 3" AS NEEDED SP-1007E-XX 3" 2 CS05 3" x 12" 1 CS05 3" x 8" 2 CS05 3" 1 CS05 3" 2 S P-1008A-XX 3" 1 H P02 5/8" X 13/4" 24 CS05 OUTLET %2", HEADER 3/4" 1 CS05 j2" x 4" 1 CS05 %2" 1 H P02 3" 4 ENGINEERS • MANUFACTURERS • CONSTRUCTORS DWG. SHEET REV NO. RA -STD -271-3 1 OF 1 FRONT VIEW SPIROS1623 6/25/2024 2:19:20 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-274-2.DWG NOTES: 1. INSTALL AT TOP OF BERM GRADE. 2. FASTEN TO SIDE OF WET WELL USING GALVANIZED PIPE HANGER STRAPS. V rl I LJL, LJI 17 LJI II 1 LEVEL SWITCHES LIFT STATION PLAN VIEW DETAIL A: LIFT STATION ELEVATION VIEW NOTE 4 IN UNDERGROUND PIPING CONTRACTOR'S SCOPE IN UNDERGROUND PIPING CONTRACTOR'S SCOPE 8" HDPE SDR 17 FORCED SEWER NOTES: 1. PIPE SIZES MAY VARY PER LIFT STATION, SEE PIPING ALIGNMENT DRAWINGS FOR SIZES. 2. SEE RA-STD-285 FOR PRECAST LIFT STATION FABRICATION DETAILS. 3. RAILING OR GRATING IS REQUIRED FOR LIFT STATIONS THAT EXTEND ABOVE GRADE LESS THAN 42". 4. SEE RA-STD-287 FOR VALVE BOX INSTALLATION DETAILS. 5. SIZES AND COMPONENTS MAY VARY PER VALVE BOX. SEE ALIGNMENT DRAWINGS AND ATTACHED TABLE FOR DETAILS. 6. PACKING MUST BE TIGHTENED AT INSTALL. 7. ROTATE OUT OF WAY OF OVERHEAD PIPE. FLOATS 1 ALARM HIGH WATER 2 PUMP OFF 3 LEAD PUMP ON 4 LAG PUMP ON SPIROS1623 3/6/2024 4:26:48 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GEN ERAL\RA-STD-280-2. DWG ISE�C _ n k6059 srr% 09/27/2024 NOTES: z NOTE 2 N 0,:":":m TOP OF BERM aaa i l i i l i i l i i l i i l i i l i i � I I I NOTE 1 I SSPIROS1623 12/7/2023 10:52:52 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-282.DWG EDGE OF BERM NOTE 4 z N vl- POWER FLUSH PLAN VIEW FLOATING COVER WET WELL POWER FLUSH ELEVATION VIEW LAGOON SLOPED WALL 1 3 NOTE 3 . MINIMUM OF 1 5' FROM EDGE OF THE COVER. REFER TO FARM OPERATOR FOR EXACT LOCATION. 2. 6" POWER FLUSH INSTALLED ADJACENT TO WET WELL LATERAL. 3. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 4. SEE RA-STD-2 53 FOR ANCHOR TRENCH DETAILS. HIGH PUMP LOW PUMP LOW LAGOON PRECAST LIFT STATION PLAN VIEW WATERTIGHT, FLEXIBLE GASKET- Q A-LOK C107-16 AND CLAMP CL-EV15-18-L. w OVERFLOW SEE INSTALLATION INSTRUCTIONS. p < 12" PVC SDR 35 INSIDE OF WET WELL DO NOT MORTAR TOP HALF OF PIPE LINE. ry O OUTSIDE OF WET WELL DO NOT MORTAR. w O Q 2" x 2" NOTCH 10" MIN. FOR LID 0 - - - - - - - - - - - - a w - p o w o a 9" INFI-SHIELD GATOR WRAP OR EQUAL INFLUENT X" ADS-1\112 WATERTIGHT, FLEXIBLE GASKET- A-LOK C107-16 AND CLAMP CL-EV15-18-L. SEE INSTALLATION INSTRUCTIONS. INSIDE OF WET WELL DO NOT MORTAR TOP HALF OF PIPE LINE. OUTSIDE OF WET WELL DO NOT MORTAR. COMPACTED EAR} I' UNDISTURBED EARTH SPIROS1623 3/6/2024 4:28:39 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-285-2.DWG [-Y QT PRECAST LIFT STATION ELEVATION VIEW FINISH GRADE 1" CLR (TYP) 6vl N MASTIC ON INSIDE & OUTSIDE JOINT EDGES. SNYDER "RAM-NEK" EQUAL. #6 @ 7", BOTH WAYS, BOTH FACES #6 @ 7", BOTH WAYS, BOTH FACES LIFT STATION 1 LIFT STATION 2 LIFT STATION 3 PD (IN) AG (IN) INFLUENT PIPE SIZE (IN) ''� SAS .:}'OC'''�'�i IISE ; i 1956059 �����I/• 1111111����� 09/ PIPE INSTALLATION INSTRUCTIONS: 1. BEVEL PIPE. CLEAN CONNECTOR. CLEAN PIPE OF DIRT AND DEBRIS. 2. CENTER PIPE IN CONNECTOR AND PUSH THROUGH. 3. ATTACH PROPER SIZE CLAMP BESIDE O-RING THEN CENTER PIPE IN CONNECTION AND TIGHTEN CLAMP WITH TORQUE WRENCH TO 60 INCH POUNDS. NOTFS- 1. PRECAST CONCRETE LIFT STATION STRUCTURE SHALL MEET ASTM-913 STANDARDS. 2. CONCRETE SHALL HAVE A WATER TO CEMENT RATIO OF 0.45 OR LESS NOTES: 6 � 5 � 4 1 3 1 2 NOTE 4 1 NOTE 5 L 0.5% SLOPE 1 NOTE 3 1 � 1 OTE 6 3 FLOATING COVER 1 NOTE 1 97 GCS CONDENSATE RETURN INSTALLATION DETAILS ELEVATION VIEW 1. FOR PLASTIC LINED LAGOONS, SEE RA-STD-270 FOR LINER PENETRATION DETAILS. FOR CLAY LINED LAGOONS, ADHERE TO NOTE 2. 2. A BENTONITE SLEEVE, 6" MINIMUM THICKNESS, SHALL BE COMPACTED AROUND THE FULL DIAMETER OF THE PIPE, EXTENDING BACK 36" FROM THE PIPE PENETRATION. ALL BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 3. SEE RA-STD-253 FOR ANCHOR TRENCH INSTALLATION DETAILS. 4. CONNECTS TO GCS CONDENSATE DISCHARGE. 5. SEE GENERAL ARRANGEMENTS FOR EXACT LOCATION. I-'6. COVER CONTRACT R TO SUPPLY MANUFACTURED BOOT. HIGH PUMP LOW PUMP LOW LAGOON SPIROS1623 3/6/2024 9:56:41 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-288.DWG ISE�C _ n k6059 srr% 09/27/2024 2 3" SDR11 3'-0" MIN. 5 ART SYSTEM CONNECTION ELEVATION VIEW li III III III I 1 3 EVAPORATION LAGOON CONNECT TO INFUSER NOZZLE 6PIROS1623 3/6/2024 4:31:01 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-295.DWG ISE�C 056059 8rn= 09/27/2024