Loading...
HomeMy WebLinkAboutWQ0045799_Comments_20241011 1 EARTHWöRKS planning anddesign di n consultants It'October 8, 2024 North Carolina Department of Environmental Quality Division of Water Resources, Water Quality Section, Municipal Permitting Unit 512 North Salisbury St., Raleigh, NC, 27604 1617 Mail Service Center, Raleigh, NC, 27699-1617 RECEIVED Attention: H. Dale Crisp, PE 919-707-3603 OCT 11 2024 RE: Admirals Cove — Comment Responses Round #1 NCDEQ/DWR/NPDES Low Pressure Sewer Design Brunswick County, NC EW# 221138 Dear NCDEQ: Enclosed are the revised plan sheets, calculations and comment responses below: 1. Proposed project is for the installation of 204 residential simplex grinder pump stations, 2 duplex grinder pump stations serving pool/amenity centers and the associated low pressure sewer mains and force mains to serve the Admirals Cove LPSS and connect to the Brunswick Country sewer system. The additional sewer flowrate requested for the subject permit application is a total of 46,200 GPD. The submitted ASEA does not include approximate pressure sewer main lengths or the size diameter of the pressure sewer mains but rather is a note indicating these lengths can be found in tables in the supporting documents. Such a table was found on sheet C2.3 of the engineering plans. Please provide this type of table as an attachment to be added to the ASEA as required, including the size diameter and estimated total lengths of each diameter of the pressure sewer mains. This table has been copied below and is a separate sheet that can be attached to the ASEA application. 11655 Highway 707•P.O. Box 201 •Murrells Inlet,South Carolina 29576 Phone: (843)651-7900•Facsimile: (843)651-7903•www.earthworksgroup.com 1 LOW PRESSURE SEWER COLLECTION &TRANSMISSION FORCEMAINS BRANCH ROAD NAME PIPE FOOTAGE PIPE DIAMETER 2 3 4 6 NW ADMIRAL FORD LOOP 1,218 866 352 0 0 NE ADMIRAL FORD LOOP 996 770 226 0 0 BOARDWALK WAY; SE VALIANT WAY 1,735 305 1,245 185 0 SE-2A MARBLE DRIVE 222 222 0 0 0 SE-5 BOARDWALK WAY 181 181 0 0 0 SYLVIA POINT; SW SOUTHPORT SHOALS 1,915 850 880 185 0 SW-5 BOARDWALK WAY 205 205 0 0 0 DUPLEX-1 - 188 188 0 0 0 DUPLEX-2 - 80 80 0 0 0 6" FM ZION HILL ROAD 1,800 0 0 0 1,800 TOTALS 8,540 3,667 2,703 370 1,800 2. No anti-flotation calculations appear to be submitted for the typical detail of the simplex and duplex grinder sewer pump stations in the supporting information for the permit application as required. Please provide the signed and sealed calculations. See attached signed/sealed calculations for simplex and duplex stations. 3. No pump station emergency storage calculations appear to be submitted as required in support of the indication on the permit application of 360 gallons of storage is available during a power outage for the simplex grinder sewer pump stations. Please provide the signed and sealed calculations. See attached signed/sealed calculations for simplex and duplex stations. 4. The project narrative letter indicates portable emergency generators will be provided for the stations duringpower outages and the submitted construction duplexgrinder sewer pump g p specifications provided general information for such generators that are acceptable to Brunswick County, but no specific information such as proposed manufacturer, capacity, etc. is provided for these generators. Please provide this information. The County owns multiple towable Cummins _generators that are mounted on a chassis with internal Tier 4 diesel fuel tank & 25 kW capacity to serve these stations in event of power outage. NCDEQ LOW PRESSURE SEWER COMMENT RESPONSE ROUND1 10.08.2024 Page 2 of 4 5. The engineering plans submitted with the supporting information to the ASEA permit application include profile information sheets. However, the minimum cover from existing or proposed ground elevation is not labeled on these sheets. The actual vertical separations of the proposed pressure sewer mains and force mains for their crossing points of proposed storm sewers and crossing points of proposed potable water mains appears to be provided in feet but is not labeled as such. Please clarify. All dimensions shown for pipe separations are in feet and have been labeled as such. All pipes will maintain a minimum of three feet of cover over the top of the pipes. All utilities will maintain their respective clearances between water, wastewater, and stormwater conduits. 6. Sheet C2.10 provides profile information for the proposed 6-inch diameter C-900 PVC force main along Zion Hill Road. The minimum pipe cover is not labeled, and from the prolife it does not appear 3 feet of cover is provided from the existing ground elevation. Please clarify and revise as appropriate to provide 3 feet of cover or utilize ductile iron pipe for the force main. Also, the vertical separation for the crossing of the existing water main at approximately station 14+50 is not labeled at all. Please add this vertical separation information at this crossing location. All dimensions shown for pipe separations are in feet and have been labeled as such. All pipes will maintain a minimum of three feet of cover over the top of the pipes. All utilities will maintain their respective clearances between water, wastewater, and stormwater conduits. 7. The submitted modeling summary information for the LPSS indicates a C factor of 130 was utilized for the modeling of the system. The Division's Minimum Design Guidelines for Pump Stations and Force mains requires a C factor of 120 be utilized when making such calculations for end-of service conditions for the proposed system. Please revise and provide this summary information utilizing a C factor of 120. All pipes in the model have been changed to C = 120 and re-ran for average and peak daily demands. The revised output files are provided in the report. EARTH W . KS - • =-- -. - NCDEQ LOW PRESSURE SEWER COMMENT RESPONSE ROUND1 10.08.2024 Page 3 of 4 A response to the above comments is considered required in order to proceed with the review of the application and issuance of the permit. If a complete response is not received within 30 days, the application and supporting documents will be returned to you in accordance with 15A NCAC 02T.0107(e)(2). Please feel free to provide digital copies of these revised documents and supporting information to me via email along with hardcopies via mail. Acknowledged. If you have any questions, please feel free to contact our office at 843-651-7900. Sincerely, Steve Strickland, PE The EARTHWORKS Group EARTHW INKS NCDEQ LOW PRESSURE SEWER COMMENT RESPONSE ROUND1 10.08.2024 Page 4 of 4 EARTHW RKS planning and design consultants ADMIRALS COVE LOW PRESSURE SEWER COLLECTION ENGINEERING REPORT & DESIGN CALCS BRUNSWICK COUNTY, NC March 1 , 2024 REVISED 10-08-2024 PREPARED FOR PALM LAND DEVELOPMENT LLC MARK PERLE, EXECUTIVE MANAGER 4030 WAKE FOREST RD # 349 RALEIGH, NC 27609-0010 PREPARED BY The EARTHWORKS Group 11655 HIGHWAY 707, P.O. BOX 201 MURRELLS INLET, SC 29576 EW PROJECT #221138 . . THE 9 Q EARTHWORKS it&J x; o GROUP, INC.e _ e' • 804za a_ ANO:C-2249 : �� �'' • ,' �.' 10/8/24 -z "61- //11l11!!III11\\\\\\\ //1111!!1111k1110 • • Inlet, South Carolina 29576 11655 Highway 707• P.O. Box 201 • Murrells C o 9 Y Phone: (843)651-7900 • Facsimile: (843)651-7903•www.earthworksgroup.com EARTHWRKS planning and design consultant, Admirals Cove Brunswick County, North Carolina ENGINEERING REPORT: REVISED 10-08-2024 LOW-PRESSURE SEWER COLLECTION SYSTEM PROJECT DESCRIPTION The subject development is Admirals Cove, located along Zion Hill Road in Brunswick County, NC. The property is within the utility jurisdiction of Brunswick County Public Utilities, and is located southeast of densely developed residential areas near the Town of Supply and Varnamtown. The site is located on two parcels with a total acreage of 77.2 acres (3,362,832 sqft). Elevations on the future developed portions of the property range between 20-42 feet MSL. The southern portions of the property lie within the floodplain of the Lockwoods Folly River at near sea level. These parcels are summarized below: Owner: Palm Land Development, LLC 4030 Wake Forest Rd, Suite 349, Raleigh, NC 27609 Parcel PIN: 203705290936 (39.4 acres) Parcel PIN: 203817108301 (37.8 acres) The proposed residential development will be 204 single family homes that are to be long-term leased properties on 5,000 sqft lots. A community pool is proposed at the southern end of the parcel and a separate amenity center is located just off Zion Hill Road. The community will have paved roads, stormwater system with a wet detention ponds, mail kiosks with parking, and extensive open space in the unimpacted wetlands adjoining the Lockwoods Folly River. All of the new development will be served with public water from Brunswick County Public Utilities via existing 12" potable main along Zion Hill Road. The development will be served with public sewer via low-pressure collection mains and forcemain connection to the existing low-pressure system at Winding River Plantation, located approximately one half mile to the north. Ultimately, wastewater will be pumped via a series of central pumping stations to the West Brunswick Wastewater Treatment Plant. EXISTING SEWER SYSTEM WINDING RIVER PLANTATION An existing low-pressure collection system is located approximately one half mile to the north that serves portions of the Winding River Plantation community. This is a part of an expansive golf course resort that has multiple phases and entrances off Zion Hill Road. In addition to the low-pressure collection system that serves most of the single family homes, there is a mix of condominiums and a large clubhouse that is served by gravity sewer and a central pump station. All wastewater is tributary to this Winding River PS#2 and then pumped to the West Brunswick Wastewater Treatment Plant located approximately six miles to the north. 11655 Highway 707•P.O.Box 201 •Murrells Inlet,South Carolina 29576 Phone:(843)651-7900•Facsimile:(843)651-7903•www.earthworksgroup.com NCDEQ & BRUNSWICK COUNTY DESIGN GUIDELINES The following design guidelines were used to design the low-pressure sewer system to serve the Admirals Cove development: • North Carolina Administrative Code (NCAC) Title 15A Subchapter 2T Section .0305: Design Criteria for Construction of Sewers and Sewer Extensions • Brunswick County Utilities Design Standards Part E: Low Pressure Sewer Systems and Grinder Pumps • Brunswick County Technical Specification TS-021: Low Pressure Sewer Systems & Grinder Pumps • Brunswick County Technical Specification TS-022: Waste Water Force Mains • rn USEPA Wastewater Technology Alternative Fact Sheet for to at Sewers, Pressure PROPOSED LOW-PRESSURE SYSTEM INFRASTRUCTURE The proposed low-pressure collection system is described as follows: • Four (4) separate Zones or Branches in the collection system • Zone Northwest (N.W.) o Total of 43 single family connections • Zone Northeast (N.W.) o Total of 29 single family connections • Zone Southeast (SE) o Total of 67 single family connections O 1 @ Duplex connection @ Community Amenity#1 Location • Zone Southwest (SW) o Total of 65 single family connections O 1 @ Duplex connection @ Community Amenity#2 Location • Total of 204 residential lots will use simplex grinder stations o Approved pump model is Barnes Omni-Grind Plus OGP2022L o Packaged station to be installed and maintained by Brunswick County o Electrical: 240 Volt, 60 Hz, Single Phase, 3450 rpm O 42" Basins with 360 gallons storage above PUMP-ON elevation o Total Unit Depth = 6.5 feet (78") for virtually all locations • 2 pool/amenities will use duplex grinder stations o Approved pump model is Barnes Omni-Grind Plus OGP2022L O 2 identical pumps in single 42" wet well o Packaged station detail provided by Brunswick County o Packaged station can be installed by private contractor or Brunswick County o To be maintained by private contractor in most cases • 2"-4" collection system piping is SDR-21 PVC o Total of +/- 6,740 LF • 6" transmission forcemain is DR-18 C900 PVC o Connection to existing Winding River low-pressure collection o Total of +/- 1,800 LF • Service laterals will be SDR-9 Polyethylene (PE) • Air release valves and flushing cleanout stations will be provided as required 2IPage PROPOSED FLOW RATES PER ZONE Brunswick County Public Utilities has standard specifications for the pump model and installed dimensions of simplex and duplex grinder stations in the County's service area. The standard pump is the Barnes Omni-Grind Plus OGP2022L in both simplex and duplex stations. This analysis assumes that the simplex pump will deliver a flow rate if 10 gpm into the collection system during average daily conditions and 14 gpm during peak daily conditions. Additionally, the duplex pump stations will deliver a flow rate if 20 gpm into the collection system during average daily conditions and 28 gpm during peak daily conditions. Hazen-Williams C-factor is 120 in this analysis. Per the NCDEQ 2T Rules, hydraulic modeling of the low-pressure system shall be provided using the statistical (projected) number of pumps running at one time. The number of simultaneous pump operations was referenced from the widely used statistical analysis provided by the E-One pump manufacturer for a historical study of low-pressure system operations in Albany, NY and is in the report appendices. The number of simultaneous operations and corresponding average/peak flows is summarized in the below table: SIMPLEX PUMP STATIONS @ SINGLE-FAMILY RESIDENTIAL LOCATIONS SIMULTANEOUS OPERATIONS FLOWS # AVG. PEAK AVG. NODE PEAK NODE RATIO ZONE OPS GPM GPM # NODES GPM GPM GPM GPM (PEAK/AVG.) NW 7 10 14 6 70 11.67 98 16.33 1.4 NE 7 10 14 6 70 11.67 98 16.33 1.4 SE 7 10 14 7 70 10.00 98 14.00 1.4 SW 7 10 14 6 70 11.67 98 16.33 1.4 DUPLEX PUMP STATIONS @ NON-RESIDENTIAL LOCATIONS SIMULTANEOUS OPERATIONS FLOWS # AVG. PEAK AVG. NODE PEAK NODE RATIO ZONE OPS GPM GPM #NODES GPM GPM GPM GPM (PEAK/AVG.) AMENITY-1 1 20 28 1 20 20.00 28 28.00 1.4 AMENITY-2 1 20 28 1 20 20.00 28 28.00 1.4 TOTALS 250 73.33 350 102.67 1.4 PROPOSED OPERATING CONDITIONS (a. FULL BUILD-OUT As previously discussed, the existing ground elevations at the site range between 20-42 feet MSL. The proposed low-pressure system would typically operate in the +/- 30 psi range during average daily flow conditions (250 gpm) at the higher elevations near Zion Hill Road where ground elevations are 40-42 feet. This is also the location of the proposed 6" forcemain that serves as the relief for the system and transmission to the interconnection with the Winding River Plantation collection system. Lower elevations in the SE and SW zones would have higher static heads of up to 20 feet, but would still operate between 30-50 psi. Pipe velocities range from 2-3 feet per second (fps). 3IPage Peak daily flow conditions (350 gpm) increase operating pressures by 5-10 psi depending upon elevation and line size and range between 30-62 psi on the collection system. All pipe velocities in the collection system and forcemain are between 2.2-4.5 feet per second (fps). At the proposed interconnection point to Winding River low-pressure along Zion Hill Road, the existing condition at Winding River (static) is estimated to operate @ +/- 30 psi for this analysis (hydraulic grade of 105 feet MSL). The proposed 6" forcemain will be located within the NCDOT ROW approximately 5 feet inside the ROW boundary. The new 6" PVC forcemain will have to maintain 10 feet separations from the existing water mains in this area, which appear to cross the road near this location according to Brunswick GIS data. The new 6" PVC forcemain will connect to the existing 6" PVC forcemain via Tapping Sleeve & Valve with a combination Air Release Valve (ARV) & pumper In-Line cleanout at a location to be approved by the County. CONCLUSIONS A future forcemain stubout (per Detail S-18) may be required by Brunswick County at the Admirals Cove end along Zion Hill Road to provide a connection to properties eastward. Due to the large amount of vacant land with similar topography, these vacant properties may be able to be served with sewer via the proposed forcemain as indicated in this report. As Zion Hill Road approaches Sunset Harbor Road, existing communities are already served with predominantly low-pressure collection systems with a mix of gravity collection as well. 4IPage ADMIRALS COVE (EW 221138) WATER & SEWER PIPE FOOTAGE SUMMARY TABLES LOW PRESSURE SEWER COLLECTION &TRANSMISSION FORCEMAINS PIPE BRANCH ROAD NAME PIPE DIAMETER FOOTAGE 2" 3" 4" 6" NW ADMIRAL FORD LOOP 1,218 866 352 0 0 NE ADMIRAL FORD LOOP 996 770 226 0 0 SE BOARDWALK WAY; 1,735 305 1,245 185 0 VALIANT WAY SE-2A MARBLE DRIVE 222 222 0 0 0 SE-5 BOARDWALK WAY 181 181 0 0 0 SYLVIA POINT; SW 1,915 850 880 185 0 SOUTHPORT SHOALS SW-5 BOARDWALK WAY 205 205 0 0 0 DUPLEX-1 AMENITY#1 188 188 0 0 0 DUPLEX-2 AMENITY#2 80 80 0 0 0 6" FM ZION HILL ROAD 1,800 0 0 0 1,800 TOTALS 8,540 3,667 2,703 370 1,800 POTABLE WATER DISTRIBUTION MAINS BRANCH ROAD NAME PIPE PIPE DIAMETER FOOTAGE 2 6 8 WATER-1 ADMIRAL FORD LOOP 1,356 0 1,356 0 WATER-2 ADMIRAL FORD LOOP 955 95 735 125 WATER-3 BOARDWALK WAY;VALIANT WAY 2,075 0 2,075 0 WATER-4 SYLVIA POINT,SOUTHPORT SHOALS 1,897 200 1,697 _ 0 WATER-5 BOARDWALK WAY 443 0 443 0 WATER-6 MARBLE DRIVE 344 0 344 0 TOTALS 7,070 295 6,650 125 Admirals Cove - Wastewater Flow Calcs (TEG 221138) Residential & Commercial Amenity Centers Wastewater Unit Contributory Loadings Treatment Facility = West Brunswick Regional WRF - WQ0023693 Low Pressure Sewer Pumped to Winding River Plantation LP Collection REVISED: 6/18/2024 Single Family Homes All 3-Bedroom # 3 Bedroom Units 204 GPD per Unit 210 Sub-Total Residential WW Design Flows 42,840 # Commercial Units (Amenity Centers) 2 GPD per Unit 1,680 Sub-Total Commercial WW Design Flows 3,360 TOTAL WW Design Flows 46,200 PEAKING FACTOR 2.5 PEAK WW Design Flows 115,500 PEAK Pumped WW Flow Rate 80.2 WW Calcs Page 1 1 Rep'<< _�':` . y.o ! Rhs ki?, .. ..� .: .s e. , > h `p Y M31Aa ) '',� x Dec, Y '�y, 7/\ rl/: it P. S. n. js yj a y f T - -�� �G ter`+ '�' � � �' I� •& ,,,.. , t.4.•,,:•-#:,,,,-- ./ _ 4° I :'=„2,„‘"\A. „-...i• i- .4,,,,.'4.,,,A", \7, ,,,1-: # e s Aft' :: ! ~OgRoY >i .` , sty fa r- `' , " Pr R Y 5. K • 7) O x c� �!�s� � mO ��� vt H I";. rj y 1;: n Zr ' * .r ' �' rzn ;' tM \r o m O O - 4 o° Oa 4s •;C) G -ti R a 4 ., .., ,,,,41-r/ilil..-1,:-..,...i.1!...4,.,,,..::_,,..ro. p-1,4,..,_,...,- ...t..v6 .,- 0) 3 .5", ' t-- litt il.,.;''',. ''ei.,0". ., C,..9.: -.41".i,,,,4•',,-..,-,: Fd . 13 t,• art-R *J .r( :44. '. r nn3 r •'4 .. -� NeoP T .fir ' a. �� „ . r N' . tat � y� /I Fk k t ► ; A` « . ;° Scenario: Base m J-NW2 J-NE2 }i? R-RIVER LANDING LPS h J-NW3 P W3 > — w_ J-NE3 (7 11 cc p V 00 Z z P-ZION HI L FM-2 P-ZION HI L FM-1 a d J-ZION HILL CONN-E J-WINDING RIVER Ca N = J-ZION HIL .ONN-W 0 —A J-SW6 J-SE7 A J-S W 5 J-AMENITY DUPLEX _':_~ Q d -.,E> J-SE. -o . Color Coding Legend 1`rn Pipe:Diameter(m) ,I-5E5 <= 2.0 J-SW4 <= 3.0 <= 4.0 A.6 -o in <= 6.0 Color Coding Legend Other Junction:Pressure(psi) J-SW3 <= 40.00 h o- <= 50.00 ® <= 60.00 70.00 • < 80.00 Other Sewer Low Pressure Model Admirals Cove_FINAL 10.08.2024.wtg Bentley Systems, Inc. Haestad Methods Solution Center 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT 06787 USA +1-203-755-1666 JUNCTION - AVERAGE DAILY FLOWS (SORTED BY NAME) FlexTable: Junction Table Label Demand Elevation Hydraulic Grade Pressure Head Pressure (gpm) (ft) (ft) (ft) (psi) - J AMENITY -20.0 40.00 117.12 77.12 33.37 DUPLEX J-NE1 -20.0 42.00 135.16 93.16 40.30 J-NE2 -7.5 41.00 129.74 88.74 38.40 3-NE3 -7.5 40.00 119.98 79.98 34.60 J-NW1 -20.0 42.00 140.00 98.00 42.40 J-NW2 -7.5 42.00 133.74 91.74 39.69 J-NW3 -7.5 40.00 122.43 82.43 35.67 J-POOL DUPLEX -20.0 25.00 135.59 110.59 47.85 J-SE1 -20.0 25.00 138.72 113.72 49.20 J-SE2 -2.5 25.00 134.17 109.17 47.23 J-SE3 -2.5 30.00 130.01 100.01 43.27 J-SE4 -20.0 30.00 132.29 102.29 44.26 J-SE5 -2.5 35.00 123.70 88.70 38.38 J-SE6 -2.5 40.00 116.94 76.94 33.29 J-SE7 -20.0 40.00 119.93 79.93 34.58 J-SW1 -20.0 25.00 139.62 114.62 49.59 J-SW2 -7.5 25.00 133.21 108.21 46.82 J-SW3 -7.5 30.00 121.66 91.66 39.66 J-SW4 -7.5 35.00 119.21 84.21 36.43 J-SW5 -7.5 40.00 115.69 75.69 32.75 J-SW6 -20.0 40.00 118.68 78.68 34.04 J WINDING 0.0 35.00 105.07 70.07 30.32 RIVER CONN ] ZION HILL 0.0 40.00 115.36 75.36 32.60 CONN-E J ZION HILL 0.0 40.00 114.12 74.12 32.07 CONN-W Sewer Low Pressure Model Admirals Bentley Systems,Inc. Haestad Methods Solution WaterCAD Cove_F I NAL.wtg Center [24.00.00.26] 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT Page 1 of 1 06787 USA +1-203-755-1666 JUNCTION - AVERAGE DAILY FLOWS (SORTED BY PRESSURE) FlexTable: Junction Table Label Demand Elevation Hydraulic Grade Pressure Head Pressure (gpm) (ft) (ft) (ft) (psi) J-SW1 -20.0 25.00 139.62 114.62 49.59 J-SE1 -20.0 25.00 138.72 113.72 49.20 J-POOL DUPLEX -20.0 25.00 135.59 110.59 47.85 J-SE2 -2.5 25.00 134.17 109.17 47.23 J-SW2 -7.5 25.00 133.21 108.21 46.82 J-SE4 -20.0 30.00 132.29 102.29 44.26 J-SE3 -2.5 30.00 130.01 100.01 43.27 J-NW1 -20.0 42.00 140.00 98.00 42.40 J-NE1 -20.0 42.00 135.16 93.16 40.30 J-NW2 -7.5 42.00 133.74 91.74 39.69 3-SW3 -7.5 30.00 121.66 91.66 39.66 J-NE2 -7.5 41.00 129.74 88.74 38.40 J-SE5 -2.5 35.00 123.70 88.70 38.38 J-SW4 -7.5 35.00 119.21 84.21 36.43 J-NW3 -7.5 40.00 122.43 82.43 35.67 J-NE3 -7.5 40.00 119.98 79.98 34.60 J-SE7 -20.0 40.00 119.93 79.93 34.58 3-5W6 -20.0 40.00 118.68 78.68 34.04 J AMENITY -20.0 40.00 117.12 77.12 33.37 DUPLEX J-SE6 -2.5 40.00 116.94 76.94 33.29 J-SW5 -7.5 40.00 115.69 75.69 32.75 ] ZION HILL 0.0 40.00 115.36 75.36 32.60 CONN-E J-ZION HILL 0.0 40.00 114.12 74.12 32.07 CONN-W 3-WINDING 0.0 35.00 105.07 70.07 30.32 RIVER CONN Sewer Low Pressure Model Admirals Bentley Systems,Inc. Haestad Methods Solution WaterCAD Cove_F I NAL.wtg Center [24.00.00.26] 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT Page 1 of 1 06787 USA +1-203-755-1666 PIPES - AVERAGE DAILY FLOWS (SORTED BY NAME) FlexTable: Pipe Table Label Length Diameter Start Node Stop Node Material Hazen- Flow Velocity (ft) (in) Williams C (gpm) (ft/s) P-NE1 418 2.0 J-NE1 J-NE2 PVC 120.0 20.0 2.04 P-NE2 418 2.0 J-NE2 J-NE3 PVC 120.0 27.5 2.81 P-NORTH 253 3 0 3-ZION HILL J-NE3 PVC 120.0 -70.0 3.18 TIE CONN-E P-NW1 484 2.0 J-NW2 J-NW1 PVC 120.0 -20.0 2.04 P-NW2 484 2.0 J-NW3 J-NW2 PVC 120.0 -27.5 2.81 P-NW3 484 3.0 J-NE3 J-NW3 PVC 120.0 -35.0 1.59 P-SE1 352 2.0 J-SE2 J-SE1 PVC 120.0 -20.0 2.04 P-SEIa 110 2.0 J-SE2 J POOL PVC 120.0 -20.0 2.04 DUPLEX P-SE2 572 3.0 J-SE3 J-SE2 PVC 120.0 -42.5 1.93 P-SE2a 176 2.0 3-SE3 J-SE4 PVC 120.0 -20.0 2.04 P-SE3 396 3.0 J-SE5 3-SE3 PVC 120.0 -65.0 2.95 P-SE4 396 3.0 J-SE6 J-SE5 PVC 120.0 -67.5 3.06 P-SE5 231 2.0 J-SE6 J-SE7 PVC 120.0 -20.0 2.04 P-SOUTH 220 4.0 ] ZION HILL J-SE6 PVC 120.0 -90.0 2.30 TIE CONN-E P-SW1 495 2.0 J-SW2 J-SW1 PVC 120.0 -20.0 2.04 P-SW2 495 2.0 J-SW2 J-SW3 PVC 120.0 27.5 2.81 P-SW3 484 3.0 J-SW3 J-SW4 PVC 120.0 35.0 1.59 P-SW4 484 3.0 J-SW4 3-SW5 PVC 120.0 42.5 1.93 P-SW5 231 2.0 J-SW5 J-SW6 PVC 120.0 -20.0 2.04 P-SW6 110 2.0 J AMENITY J-SW5 PVC 120.0 20.0 2.04 DUPLEX P-WEST TIE 220 4.0 J-SW5 ] ZION HILL PVC 120.0 90.0 2.30 CONN-W P-WINDING 11 6.0 R-RIVER J-WINDING PVC 120.0 -250.0 2.84 RIVER FM LANDING LPS RIVER CONN P-ZION J-ZION HILL J-ZION HILL HILL FM-1 430 6.0 CONN-W CONN-E PVC 120.0 -160.0 1.82 P-ZION 1,370 6.0 3-WINDING ] ZION HILL PVC 120.0 -250.0 2.84 HILL FM-2 RIVER CONN CONN-W Sewer Low Pressure Model Admirals Bentley Systems,Inc. Haestad Methods Solution WaterCAD Cove_F I N AL.wtg Center [24.00.00.26] 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT Page 1 of 1 06787 USA +1-203-755-1666 PIPES - AVERAGE DAILY FLOWS (SORTED BY VELOCITY) FlexTable: Pipe Table Label Length Diameter Start Node Stop Node Material Hazen- Flow Velocity (ft) (in) Williams C (gpm) (ft/s) P-NORTH 253 3.0 ] ZION HILL J-NE3 PVC 120.0 -70.0 3.18 TIE CONN-E P-SE4 396 3.0 J-SE6 J-SE5 PVC 120.0 -67.5 3.06 P-SE3 396 3.0 J-SE5 J-SE3 PVC 120.0 -65.0 2.95 P-WINDING 11 6.0 R-RIVER J-WINDING PVC 120.0 -250.0 2.84 RIVER FM LANDING LPS RIVER CONN P-ZION 1 370 6.0 J WINDING J ZION HILL PVC 120.0 -250.0 2.84 HILL FM-2 RIVER CONN CONN-W P-SW2 495 2.0 J-SW2 J-SW3 PVC 120.0 27.5 2.81 P-NW2 484 2.0 J-NW3 J-NW2 PVC 120.0 -27.5 2.81 P-NE2 418 2.0 J-NE2 J-NE3 PVC 120.0 27.5 2.81 P-WEST TIE 220 4.0 J-SW5 J ZION HILL PVC 120.0 90.0 2.30 CONN-W P-SOUTH 220 4.0 J ZION HILL J-SE6 PVC 120.0 -90.0 2.30 TIE CONN-E P-SW1 495 2.0 J-SW2 J-SW1 PVC 120.0 -20.0 2.04 P-NE1 418 2.0 J-NE1 J-NE2 PVC 120.0 20.0 2.04 P-SE1a 110 2.0 J-SE2 J POOL PVC 120.0 -20.0 2.04 DUPLEX P-NW1 484 2.0 J-NW2 J-NW1 PVC 120.0 -20.0 2.04 P-SE1 352 2.0 J-SE2 J-SE1 PVC 120.0 -20.0 2.04 P-SE2a 176 2.0 J-SE3 J-SE4 PVC 120.0 -20.0 2.04 P-SW6 110 2.0 J AMENITY J-SW5 PVC 120.0 20.0 2.04 DUPLEX P-SW5 231 2.0 J-SW5 J-SW6 PVC 120.0 -20.0 2.04 P-SE5 231 2.0 J-SE6 J-SE7 PVC 120.0 -20.0 2.04 P-SW4 484 3.0 J-SW4 J-SW5 PVC 120.0 42.5 1.93 P-SE2 572 3.0 J-SE3 J-SE2 PVC 120.0 -42.5 1.93 P-ZION J-ZION HILL J-ZION HILL HILL FM-1 430 6.0 CONN-W CONN-E PVC 120.0 -160.0 1.82 P-SW3 484 3.0 J-SW3 J-SW4 PVC 120.0 35.0 1.59 P-NW3 484 3.0 J-NE3 J-NW3 PVC 120.0 -35.0 1.59 Sewer Low Pressure Model Admirals Bentley Systems,Inc. Haestad Methods Solution WaterCAD Cove_FINAL.wtg Center [24.00.00.26] 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT Page 1 of 1 06787 USA +1-203-755-1666 JUNCTION - PEAK DAILY FLOWS (SORTED BY NAME) FlexTable: Junction Table Label Demand Elevation Hydraulic Grade Pressure Head Pressure (gpm) (ft) (ft) (ft) (psi) J AMENITY -28.0 40.00 127.60 87.60 37.90 DUPLEX J-NE1 -28.0 42.00 161.23 119.23 51.59 J-NE2 -10.5 41.00 151.14 110.14 47.65 J-NE3 -10.5 40.00 132.94 92.94 40.21 J-NW1 -28.0 42.00 170.27 128.27 55.50 J-NW2 -10.5 42.00 158.59 116.59 50.44 J-NW3 -10.5 40.00 137.51 97.51 42.19 J-POOL DUPLEX -28.0 25.00 162.04 137.04 59.29 J-SE1 -28.0 25.00 167.89 142.89 61.82 J-SE2 -3.5 25.00 159.39 134.39 58.14 J-SE3 -3.5 30.00 151.65 121.65 52.63 J-SE4 -28.0 30.00 155.90 125.90 54.47 J-SE5 -3.5 35.00 139.88 104.88 45.38 J-SE6 -3.5 40.00 127.26 87.26 37.75 J-SE7 -28.0 40.00 132.83 92.83 40.16 3-SW1 -28.0 25.00 169.57 144.57 62.55 J-SW2 -10.5 25.00 157.61 132.61 57.38 J-SW3 -10.5 30.00 136.06 106.06 45.89 J-SW4 -10.5 35.00 131.49 96.49 41.75 J-SW5 -10.5 40.00 124.94 84.94 36.75 J-SW6 -28.0 40.00 130.52 90.52 39.16 3-WINDING 0.0 35.00 105.14 70.14 30.34 RIVER CONN J ZION HILL 0.0 40.00 124.31 84.31 36.48 CONN-E ] ZION HILL 0.0 40.00 122.00 82.00 35.48 CONN-W Sewer Low Pressure Model Admirals Bentley Systems,Inc. Haestad Methods Solution WaterCAD Cove_FINAL.wtg Center [24.00.00.26] 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT Page 1 of 1 06787 USA +1-203-755-1666 JUNCTION - PEAK DAILY FLOWS (SORTED BY PRESSURE) FlexTable: Junction Table Label Demand Elevation Hydraulic Grade Pressure Head Pressure (gpm) (ft) (ft) (ft) (psi) 3-SW1 -28.0 25.00 169.57 144.57 62.55 J-SE1 -28.0 25.00 167.89 142.89 61.82 J-POOL DUPLEX -28.0 25.00 162.04 137.04 59.29 J-SE2 -3.5 25.00 159.39 134.39 58.14 J-SW2 -10.5 25.00 157.61 132.61 57.38 J-NW1 -28.0 42.00 170.27 128.27 55.50 J-SE4 -28.0 30.00 155.90 125.90 54.47 J-SE3 -3.5 30.00 151.65 121.65 52.63 J-NE1 -28.0 42.00 161.23 119.23 51.59 J-NW2 -10.5 42.00 158.59 116.59 50.44 J-NE2 -10.5 41.00 151.14 110.14 47.65 J-SW3 -10.5 30.00 136.06 106.06 45.89 J-5E5 -3.5 35.00 139.88 104.88 45.38 J-NW3 -10.5 40.00 137.51 97.51 42.19 3-SW4 -10.5 35.00 131.49 96.49 41.75 J-NE3 -10.5 40.00 132.94 92.94 40.21 J-SE7 -28.0 40.00 132.83 92.83 40.16 J-SW6 -28.0 40.00 130.52 90.52 39.16 J AMENITY -28.0 40.00 127.60 87.60 37.90 DUPLEX J-SE6 -3.5 40.00 127.26 87.26 37.75 J-SW5 -10.5 40.00 124.94 84.94 36.75 ] ZION HILL 0.0 40.00 124.31 84.31 36.48 CONN-E J ZION HILL 0.0 40.00 122.00 82.00 35.48 CONN-W ]-WINDING 0.0 35.00 105.14 70.14 30.34 RIVER CONN Sewer Low Pressure Model Admirals Bentley Systems,Inc. Haestad Methods Solution WaterCAD Cove_F I N AL.wtg Center [24.00.00.26] 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT Page 1 of 1 06787 USA +1-203-755-1666 PIPES - PEAK DAILY FLOWS (SORTED BY NAME) FlexTable: Pipe Table Label Length Diameter Start Node Stop Node Material Hazen- Flow Velocity (ft) (in) Williams C (gpm) (ft/s) P-NE1 418 2.0 J-NE1 3-NE2 PVC 120.0 28.0 2.86 P-NE2 418 2.0 J-NE2 J-NE3 PVC 120.0 38.5 3.93 P-NORTH 253 3.0 J ZION HILL J-NE3 PVC 120.0 -98.0 4.45 TIE CONN-E P-NW1 484 2.0 J-NW2 J-NW1 PVC 120.0 -28.0 2.86 P-NW2 484 2.0 J-NW3 J-NW2 PVC 120.0 -38.5 3.93 P-NW3 484 3.0 J-NE3 J-NW3 PVC 120.0 -49.0 2.22 P-SE1 352 2.0 J-SE2 J-SE1 PVC 120.0 -28.0 2.86 P-SE1a 110 2.0 J-SE2 J POOL PVC 120.0 -28.0 2.86 DUPLEX P-SE2 572 3.0 J-SE3 J-SE2 PVC 120.0 -59.5 2.70 P-SE2a 176 2.0 J-SE3 J-SE4 PVC 120.0 -28.0 2.86 P-SE3 396 3.0 J-SE5 J-SE3 PVC 120.0 -91.0 4.13 P-SE4 396 3.0 J-SE6 J-SE5 PVC 120.0 -94.5 4.29 P-SE5 231 2.0 J-SE6 J-SE7 PVC 120.0 -28.0 2.86 P-SOUTH 220 4.0 ] ZION HILL J-SE6 PVC 120.0 -126.0 3.22 TIE CONN-E P-SW1 495 2.0 J-SW2 J-SW1 PVC 120.0 -28.0 2.86 P-SW2 495 2.0 J-SW2 J-SW3 PVC 120.0 38.5 3.93 P-SW3 484 3.0 J-SW3 J-SW4 PVC 120.0 49.0 2.22 P-SW4 484 3.0 J-SW4 J-SW5 PVC 120.0 59.5 2.70 P-SW5 231 2.0 J-SW5 J-SW6 PVC 120.0 -28.0 2.86 P-SW6 110 2.0 J AMENITY J-SW5 PVC 120.0 28.0 2.86 DUPLEX P-WEST TIE 220 4.0 J-SW5 J-ZION HILL PVC 120.0 126.0 3.22 CONN-W P-WINDING 11 6.0 R-RIVER J-WINDING PVC 120.0 -350.0 3.97 RIVER FM LANDING LPS RIVER CONN P-ZION J-ZION HILL J-ZION HILL HILL FM-1 430 6.0 CONN-W CONN-E PVC 120.0 -224.0 2.54 P-ZION 1,370 6.0 J-WINDING J-ZION HILL PVC 120.0 -350.0 3.97 HILL FM-2 RIVER CONN CONN-W Sewer Low Pressure Model Admirals Bentley Systems,Inc. Haestad Methods Solution WaterCAD Cove_F I NAL.wtg Center [24.00.00.26] 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT Page 1 of 1 06787 USA +1-203-755-1666 JUNCTION - PEAK DAILY FLOWS (SORTED BY VELOCITY) FlexTable: Junction Table Label Length Diameter Start Node Stop Node Material Hazen- Flow Velocity (ft) (in) Williams C (gpm) (ft/s) P-NORTH 253 3.0 J ZION HILL J-NE3 PVC 120.0 -98.0 4.45 TIE CONN-E P-SE4 396 3.0 J-SE6 J-SE5 PVC 120.0 -94.5 4.29 P-SE3 396 3.0 J-SE5 J-SE3 PVC 120.0 -91.0 4.13 P-WINDING 11 6.0 R-RIVER J-WINDING PVC 120.0 -350.0 3.97 RIVER FM LANDING LPS RIVER CONN P-ZION 1 370 6.0 J-WINDING J-ZION HILL PVC 120.0 -350.0 3.97 HILL FM-2 RIVER CONN CONN-W P-SW2 495 2.0 J-SW2 J-SW3 PVC 120.0 38.5 3.93 P-NW2 484 2.0 J-NW3 J-NW2 PVC 120.0 -38.5 3.93 P-NE2 418 2.0 J-NE2 J-NE3 PVC 120.0 38.5 3.93 1 P-WEST TIE 220 4.0 J-SW5 J-ZION HILL PVC 120.0 126.0 3.22 CONN-W P-SOUTH 220 4.0 J ZION HILL J-SE6 PVC 120.0 -126.0 3.22 TIE CONN-E P-SW1 495 2.0 J-SW2 3-SW1 PVC 120.0 -28.0 2.86 P-NE1 418 2.0 J-NE1 J-NE2 PVC 120.0 28.0 2.86 P-SE1a 110 2.0 J-SE2 J POOL PVC 120.0 -28.0 2.86 DUPLEX P-NW1 484 2.0 J-NW2 J-NW1 PVC 120.0 -28.0 2.86 P-SE1 352 2.0 J-SE2 J-SE1 PVC 120.0 -28.0 2.86 P-SE2a 176 2.0 J-SE3 J-SE4 PVC 120.0 -28.0 2.86 P-SW6 110 2 0 J AMENITY J-SW5 PVC 120.0 28.0 2.86 DUPLEX P-SW5 231 2.0 J-SW5 J-SW6 PVC 120.0 -28.0 2.86 P-SE5 231 2.0 J-SE6 J-SE7 PVC 120.0 -28.0 2.86 P-SW4 484 3.0 J-SW4 J-SW5 PVC 120.0 59.5 2.70 P-SE2 572 3.0 J-SE3 J-SE2 PVC 120.0 -59.5 2.70 P-ZION J-ZION HILL J-ZION HILL HILL FM-1 430 6.0 CONN-W CONN-E PVC 120.0 -224.0 2.54 P-SW3 484 3.0 J-SW3 J-SW4 PVC 120.0 49.0 2.22 P-NW3 484 3.0 J-NE3 J-NW3 PVC 120.0 -49.0 2.22 Sewer Low Pressure Model Admirals Bentley Systems,Inc. Haestad Methods Solution WaterCAD Cove_F I NAL.wtg Center [24.00.00.26] 10/8/2024 76 Watertown Road,Suite 2D Thomaston,CT Page 1 of 1 06787 USA +1-203-755-1666 zones 3, 4, 6, 8, 9, 11, 12, 13 and 14. Table 3 MAXIMUM NUMBER OF GRINDER PUMP CORES OPERATING DAILY Completion of Pipe Schedule Maximum Daily of Grinder and Zone Analysis Pump Cores Connected Number of Grinder Pump Cores Operating Simultaneously The data recorded on the System Flow Diagram (Figure 3) is then transferred to Table 4. 1 1 2-3 2 Table 4 Column No. Designation 4-9 3 10-18 4 1 Zone Number 19-30 5 2 Connects to Zone 3 Number of Pumps in 31-50 6 Zone 51-80 7 4 Accumulated 81-113 8 Pumps in Zone 114-146 9 11 Length of Main this 147-179 10 Zone in Feet 180-212 11 Column 4 is completed by referring to Table 3, 213-245 12 where the maximum number of pumps in simul- 246-278 13 taneous operation is given as a function of the 279-311 14 number of pumps upstream from the end of the 312-344 15 particular zone. The output of each zone will vary slightly with head requirements, but under typical 345-377 16 conditions, the flow is approximately 11 gpm. 378-410 17 Calculate the maximum anticipated flow for each 411-443 18 zone by multiplying the number of simultaneous 444-476 19 operations in Column 7 by 11 gpm and record 477-509 20 the results in Column 8. 510-542 21 To complete columns 9, 10, 12 and 13, refer to 543-575 22 Flow Velocity and Friction Head Loss table for the 576-608 23 type of pipe selected —in this case, Table 5 for 609-641 24 SDR-21. It will be seen that the engineer will 642-674 25 frequently be presented with more than one option when selecting pipe size. Sometimes a 675-707 26 compromise in pipe size will be required to meet 708-740 27 present needs as well as planned future develop- 741-773 28 ment.As a general rule, pipe sizes should be 774-806 29 selected to minimize friction losses while keep- 807-839 30 ing velocity near or above 2 feet per second. 840-872 31 For example, Zone 1 has a maximum of two 873-905 32 pumps running (Column 7). Table 5 offers a 906-938 33 choice of 1.25-inch, 1.5-inch or 2-inch pipe. 1.5- 939-971 34 inch pipe is selected since flow velocity equals 972-1,004 35 14 ADMIRALS COVE (EW 221138) WET WELL STORAGE CALCULATIONS A. Wet Well Storage Calculation -SIMPLEX GRINDER STATION 1. Wet Well Volume (from Barnes packaged lift station catalog) SIMPLEX UNIT DIMENSIONS 3.50 Wet Well diameter(feet) 42 Wet Well diameter(inches) 7.00 Wet Well depth (feet) 84 Wet Well depth(feet) 2. Bottom Elevation 0.00 INCHES 3. Pump ON Elevation 18.00 INCHES 4. ALARM Elevation 24.00 INCHES 5. RIM Elevation 84.00 INCHES 6. Wet Well Storage Calculations 52.9 Total Wet Well Storage Volume 7.48 gallons per CF 396 Storage Volume ABOVE PUMP ON 360 Storage Volume ABOVE ALARM B. Wet Well Storage Calculation -DUPLEX GRINDER STATION 1. Wet Well Volume (from Barnes packaged lift station catalog) DUPLEX UNIT DIMENSIONS 4.00 Wet Well diameter(feet) 48 Wet Well diameter(inches) 7.00 Wet Well depth (feet) 84 Wet Well depth (feet) 2. Bottom Elevation 0.00 INCHES 3. Pump ON Elevation 18.00 INCHES 4. ALARM Elevation 24.00 INCHES 5. RIM Elevation 84.00 INCHES 6. Wet Well Storage Calculations 69.1 Total Wet Well Storage Volume 7.48 gallons per CF 517 Storage Volume ABOVE PUMP ON 470 Storage Volume ABOVE ALARM `m EARTHWORKS p' GROUP INC �` ' p= 14-50 O:C-2249�W 14°3410/8 ADMIRALS COVE (EW 221138) ANTI-BUOYANCY CALCULATIONS A. Wet Well Buoyancy Calculation -SIMPLEX GRINDER STATION 1. Wet Well Volume (from Barnes packaged lift station catalog) SIMPLEX UNIT DIMENSIONS 3.50 Wet Well diameter(feet) 42 Wet Well diameter(inches) 7.00 Wet Well depth (feet) 84 Wet Well depth (feet) 0.25 Wet Well thickness (feet) 2. Ground Water Elevation 0 feet below grade 3. Total Wet Well Weight 150 Total Weight of Unit(EMPTY) 4. Buoyancy Calculation Wet Well Empty 88.0 Total Wet Well Volume 62.4 unit weight of water(pcf) 5,489 Total Buoyancy Force (lbs, acting upward) 5,339 Net Buoyancy Force (lbs, acting upward) 3.0 Poured Concrete Footer as Anchor 3,000 LBS per CY 9,000 LBS ANCHORING CONCRETE 1.69 Safety Factor Against Wet Well Flotation 1 of 2 ADMIRALS COVE (EW 221138) ANTI-BUOYANCY CALCULATIONS B. Wet Well Buoyancy Calculation -DUPLEX GRINDER STATION 1. Wet Well Volume (from Barnes packaged lift station catalog) DUPLEX UNIT DIMENSIONS 4.00 Wet Well diameter(feet) 48 Wet Well diameter(inches) 7.00 Wet Well depth (feet) 84 Wet Well depth (feet) 0.25 Wet Well thickness(feet) 2. Ground Water Elevation 0 feet below grade 3. Total Wet Well Weight 200 Total Weight of Unit(EMPTY) 4. Buoyancy Calculation Wet Well Empty 111.3 Total Wet Well Volume 62.4 unit weight of water(pcf) 6,947 Total Buoyancy Force (Ibs, acting upward) 6,747 Net Buoyancy Force (Ibs, acting upward) 3.0 Poured Concrete Footer as Anchor 3,000 LBS per CY 9,000 LBS ANCHORING CONCRETE 1.33 Safety Factor Against Wet Well Flotation tNIlCll)IiI0O� \\`\\\\O,,AtA ICIIAll1/ 4�//////// THE g ! !r 1,?, EARTHWORKS\o' = 15-1 GROUP INC. _ iy •• 6604f VAo o c-22as �� VA10/8/ ` % F� . per //1/lO OF �\\�\\ //////J!/Cj�illltls10 111\\\\���� 2 of 2 I ADMIRALS COVE (EW 221138) WATER & SEWER PIPE FOOTAGE SUMMARY TABLES LOW PRESSURE SEWER COLLECTION &TRANSMISSION FORCEMAINS PIPE BRANCH ROAD NAME PIPE DIAMETER FOOTAGE 2" 3" 4" 6" NW ADMIRAL FORD LOOP 1,218 866 352 0 0 NE ADMIRAL FORD LOOP 996 770 226 0 0 BOARDWALK WAY; SE 1,735 305 1,245 185 0 VALIANT WAY SE-2A MARBLE DRIVE 222 222 0 0 0 SE-5 BOARDWALK WAY 181 181 0 0 0 SYLVIA POINT; SW 1,915 850 880 185 0 SOUTHPORT SHOALS SW-5 BOARDWALK WAY 205 205 0 0 0 DUPLEX-1 AMENITY#1 188 188 0 0 0 DUPLEX-2 AMENITY#2 80 80 0 0 0 6" FM ZION HILL ROAD 1,800 0 0 0 1,800 TOTALS 8,540 3,667 2,703 370 1,800 POTABLE WATER DISTRIBUTION MAINS 1 PIPE BRANCH ROAD NAME PIPE DIAMETER FOOTAGE 2 6 8 WATER-1 ADMIRAL FORD LOOP 1,356 0 1,356 0 WATER-2 ADMIRAL FORD LOOP 955 95 735 125 WATER-3 BOARDWALK WAY;VALIANT WAY 2,075 0 2,075 0 WATER-4 SYLVIA POINT,SOUTHPORT SHOALS 1,897 200 1,697 0 WATER-5 BOARDWALK WAY 443 0 443 0 I WATER-6 MARBLE DRIVE 344 0 344 0 TOTALS 7,070 295 6,650 125