Loading...
HomeMy WebLinkAboutSWA000222_O&M Agreement/Plan_20241010 Operation & Maintenance Agreement Project Name: Compton Addy - Popeyes - Spout Springs, NC Project Location: 1517 NC 24-87 Cover Page Maintenance records shall be kept on the following SCM(s). This maintenance record shall be kept in a log in a known set location. Any deficient SCM elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the SCM(s). The SCM(s) on this project include (check all that apply&corresponding O&M sheets will be added automatically): Infiltration Basin Quantity: 0 _ Location(s): Infiltration Trench Quantity: 0 Location(s): Bioretention Cell Quantity: 0 Location(s): Wet Pond Quantity: 0 Location(s): Stormwater Wetland Quantity: 0 Location(s): Permeable Pavement Quantity: 0 Location(s): Sand Filter Quantity: 1 Location(s): North side of the site. Rainwater Harvesting Quantity: 0 Location(s): Green Roof Quantity: 0 Location(s): Level Spreader- Filter Strip Quantity: 0 Location(s): Proprietary System Quantity: 0 Location(s): Treatment Swale Quantity: 0 Location(s): Dry Pond Quantity: 0 Location(s): Disconnected Impervious Surface Present: No Location(s): User Defined SCM Present:_ No Location(s): Low Density Present: No Type: CLICK TO UPDATE O&M MANUAL I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each SCM above, and attached O&M tables. I agree to notify NCDEQ of any problems with the system or prior to any changes to the system or responsible party. Responsible Party: CT Spout Springs -Doug Compton Title &Organization: CT Spout Springs Street address: 3805 Edwards Rd.Suite 390 City, state, zip: Cincinnati, OH 45209 Phone number(s): (513) 256-0742 Email: djcomptonjr@comptonaddy.com Signature: Date: -2.0Z�1 I, J62' GdG,iL , a Notary Public for the State of>> ei✓e County of JJifr?i�ci c) , do hereby certify that . L�uS4 (/�'/�t.3 personally appeared before me this T$ day of do4 D Si 12.6 01 and acknowledge the due execution of the 0 erations and Mainten ce Agreem . Witness my hand and official seal, Jorin Benjamin Zola °'� Attorney aR Law - ` NOTARY PJBLIC 1 STATE OF OHIO `B�,�±="�� Sec 147.03 O.R,C, Seal My commission expires N/A STORM-EZ 8/28/2024 Version 1.5 O&M Agreement Page 1 of 1 Sand Filter Maintenance Requirements Important operation and maintenance procedures: - Manage the drainage area to reduce the sediment load to the sand filter. - Clean out the sedimentation chamber or forebay whenever sediment depth exceeds six inches. - At least once a year, skim the sand media - Replace the sand filter media whenever it fails to function properly after maintenance. After the sand filter is established, it shall be inspected quarterly and within 24 hours after every storm event greater than 1.0 inches (or 1.5 inches if in a Coastal County). Records of operation and maintenance shall be kept in a known set location and shall be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. SCM element: Potential problem: How to remediate the problem: Entire sand filter Trash/debris is present. Remove the trash/debris. Adjacent pavement (if Sediment is present on the applicable) pavement surface. Sweep or vacuum the sediment as soon as possible. Areas of bare soil and/or Regrade the soil if necessary to remove the gully, plant ground erosive gullies have cover and water until it is established. Provide lime and a one- The perimeter of the formed. time fertilizer application. sand filter • Vegetation is too short or Maintain vegetation at an appropriate height. too long. • The structure is clogged. Unclog the structure and dispose of sediment in a location The flow diversion where it will not cause impacts to streams or the SCM. structure (if applicable) The structure is damaged. Make any necessary repairs or replace if the damage is too much for repair. The inlet pipe is clogged (if Unclog the pipe and dispose of sediment in a location where it applicable). will not cause impacts to streams or the SCM. The inlet pipe is cracked or otherwise damaged (if Repair or replace the pipe. applicable). The inlet device Regrade the swale if necessary and provide erosion control Erosion is occurring in the devices such as reinforced turf matting or riprap to avoid future swale (if applicable). problems with erosion. Stone verge is clogged or Remove sediment and clogged stone and replace with clean covered in sediment (if applicable). stone. Sediment has Search for the source of the sediment and remedy the problem accumulated to a depth of if possible. Remove the sediment and dispose of it in a location greater than six inches. where it will not cause impacts to streams or the SCM. Sediment chamber (forebay) Provide additional erosion protection such as reinforced turf Erosion has occurred. matting or riprap if needed to prevent future erosion problems. Weeds are present. Remove the weeds, preferably by hand. If a pesticide is used, wipe it on the plants rather than spraying. Sand Filter Maintenance Requirements (continued) SCM element: Potential problem: How to remediate the problem: Sand chamber and Water is ponding on the Check to see if the collector system is clogged and flush if underdrain collection surface for more than 24 necessary. If water still ponds, remove the top few inches of system hours after a storm. filter bed media and replace. If water still ponds, then consult an appropriate professional. Clogging has occurred. Clean out the outlet device and dispose of sediment in a gg g location where it will not cause impacts to streams or the SCM. The outlet device The outlet device is Repair or replace the outlet device. damaged. Erosion or other signs of damage have occurred at Repair the damage and improve the flow dissipation structure. the outlet. The receiving water Discharges from the sand filter are causing erosion Contact the local NCDEQ Regional Office. or sedimentation in the receiving water.