Loading...
HomeMy WebLinkAboutSW4240902_Supplement-EZ Form_20241004 SUPPLEMENT-EZ COVER PAGE • FORMS LOADED PROJECT INFORMATION 1 Project Name Bryson Park 1-3 2 Project Area(ac) 125.51 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(as) 0 5 Is this project High or Low Density? Low 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Wdth of vegetated setbacks provided(feet) See Narrative Provided 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is.ro•osed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: r 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DISC 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION _._ 27IName and Title: Robert L.Frost,PE Principal Engineer #-- 28 'Organization: NC Design Solutions,Inc. 29 Street address: 6701 Carmel Road,Suite 205 30 City,State,Zip: Charlotte,NC 28226 31 Phone number(s): 704-614-8359 32 Email: rfrost@ncdesignsolutions.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. RE C C I'r p Designer C C \\\,,,SCAR Ili AUG 3 01024 �\pe'�F •s s; ���'� Wt.,- ` MLR-STORMWATER PROGRAM 0..•2 SE _ Signature of Designer 71 Robert L. Frost, PE - Principal Engineer • %f-0 �'G 1 N E,tipOco'''�� if0/ j. ,\\ August 29, 2024 8.29.2024 Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so,number of drainage areas/SCMs 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No CLICK TO LOAD FORM LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 _ 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 ;Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) sf f 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 5.02�`—3:1 6 Are curb outlet swales proposed? No Max. velocity from 7 Maximum longitudinal slope of curb outlet swale(s)(%) 8 Bottom width of curb outlet swale(s)(feet) table on Sheet 37 9 Maximum side slope of curb outlet swale(s)(H:V) of the approved 10 Minimum length of curb outlet swale(s)(feet) 11 Are treatment swales used instead of curb outlet swales? Yes construction t 12 Is stormwater released at the edge of the setback as dispersed flow? Yes drawings m13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: See swale calculations on Sheet 37 of approved construction drawings. Drainage ' Pervious Swale BUA Q Slope V,i�,,, V.,.,..: Flow depth Area area C # (ac) (ac) (ac) (cfs) (%) (fps) (fps) (ft) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30