Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20070191 Ver 4_More Info Received_20240909 (2)
Strickland, Bev From: Perry Isner <perryisner@wetlands-waters.com> Sent: Monday, September 9, 2024 11:43 AM To: Homewood, Sue Cc: Stygar, KRYSTYNKA B CIV USARMY CESAW (USA); Dailey, Samantha J CIV USARMY CESAW (USA) Subject: [External] Re: Request for Additional Information for Bryton IP modification, - Mecklenburg County - DWR#20070191 v4 Attachments: Declan Huntersville HEPA Base 9-5-24-8.7 CULVERTS.pdf Follow Up Flag: Follow up Flag Status: Completed CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Sorry, forgot the attachment. On Mon, Sep 9, 2024 at 11:42 AM Perry Isner <perryisner@wetlands-waters.com> wrote: Good morning Sue, the proposed crossing has been revised per the attached. The riprap has been removed from the steep portion, and is only proposed at the pool immediately downstream of the culvert outlet. It is the engineer's opinion that this will accomplish the same goal as a plunge pool. Let me know if you have any questions. Sam, cc'ingyou for your records. On Tue, Sep 3, 2024 at 2:00 PM Homewood, Sue <sue.homewood@deq.nc.gov> wrote: Hello Perry, I have reviewed the proposed modification request and require additional information to complete my review. Please respond to the items below within 30 days of this email. Please note that the application is considered "on hold" until a complete response is submitted. 1. The profile of the proposed culvert shows that there is a steep drop within the stream channel at the proposed riprap outlet. Please provide clarification of the proposed slope at this location and the feasibility of maintaining stability of the embedded riprap on a steep slope within a stream channel. The Division encourages the designer to consider whether a plunge pool may provide more long term channel stability at this location. 1 Thanks, Sue Homewood (she/her/hers) 401 & Buffer Permitting Branch Division of Water Resources sue.homewood@deq.nc.gov please note my new email address 336 813 1863 mobile 919-707-3679 office Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Perry Isner <perryisner@wetlands-waters.com> Sent: Thursday, August 8, 2024 11:30 AM To: Homewood, Sue <sue.homewood@deq.nc.gov> Subject: Re: [External] Bryton IP modification, ID # 20070191 Ver 4 CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Good morning Sue, do you have any idea when you will get to the review of this project? The applicant asked me to reach out. Thanks in advance, On Wed, Jul 24, 2024 at 8:00 AM Homewood, Sue <sue.homewood@deq.nc.gov> wrote: It just showed up and is in my queue Thanks, Sue Homewood (she/her/hers) 401 & Buffer Permitting Branch Division of Water Resources sue.homewood@deq.nc.gov please note my new email address 336 813 1863 mobile 919-707-3679 office 2 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Perry Isner <perryisner@wetlands-waters.com> Sent: Tuesday, July 23, 2024 5:21 PM To: Homewood, Sue <sue.homewood@deq.nc.gov> Subject: [External] Bryton IP modification, ID # 20070191 Ver 4 CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Good evening Sue, hope all is well. Just wanted to confirm that you have received the above referenced project, feel free to let me know if you have any questions once you've had a chance to review. Thanks in advance, Perry Isner Wetlands & Waters, Inc. 328 East Broad St. Suite D Statesville, NC 28677 704.773.4239 perryisner@wetlands-waters.com The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received this message in error, you are hereby notified that any dissemination, distribution or copy of this email is strictly prohibited. If you have received this email in error, please 3 immediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently delete this message. Thank you for your cooperation and consideration. Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. Perry Isner Wetlands & Waters, Inc. 328 East Broad St. Suite D Statesville, NC 28677 704.773.4239 perryisner@wetlands-waters.com The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received this message in error, you are hereby notified that any dissemination, distribution or copy of this email is strictly prohibited. If you have received this email in error, please immediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently delete this message. Thank you for your cooperation and consideration. Perry Isner 4 Wetlands & Waters, Inc. 328 East Broad St. Suite D Statesville, NC 28677 704.773.4239 perryisner@wetlands-waters.com The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received this message in error, you are hereby notified that any dissemination, distribution or copy of this email is strictly prohibited. If you have received this email in error, please immediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently delete this message. Thank you for your cooperation and consideration. Perry Isner Wetlands & Waters, Inc. 328 East Broad St. Suite D Statesville, NC 28677 704.773.4239 perryisner@wetlands-waters.com The information contained in this email message is confidential and may be legally privileged and is intended only for the use of the individual or entity named above. If you are not an intended recipient or if you have received this message in error, you are hereby notified that any dissemination, distribution or copy of this email is strictly prohibited. If you have received this email in error, please immediately notify us by return email or telephone if the sender's phone number is listed above, then promptly and permanently delete this message. Thank you for your cooperation and consideration. 5 �A0r PERMANENT MAINTENAN ACCESS EASEMENT CO F I I O O to0 ...Z.' our' m Jo- < 40 0 co II� r 4tilo 20 r°4 I I GRAPHIC SCALE 40 80 0 32 160 800 790 780 770 ( IN FEET ) 1 inch = 40 ft. Culvert Report Hydraflow Express Extension for Autodesk® Civil 3D® by Autodesk, Inc. Culvert CC - 25 YR Invert Elev Dn (ft) Pipe Length (ft) Slope (%) Invert Elev Up (ft) Rise (in) Shape Span (in) No. Barrels n-Value Culvert Type Culvert Entrance Coeff. K,M,c,Y,k Embankment Top Elevation (ft) Top Width (ft) Crest Width (ft) Elev Inl 269.0 78700 = 775.00 = 125.00 = 0.50 = 775.63 = 24.0 = Circular = 24.0 = 1 = 0.012 = Circular Concrete = Square edge w/headwall (C) = 0.0098, 2, 0.0398, 0.67, 0.5 = 787.00 = 30.00 = 30.00 Culvert CC -25 YR Calculations Qmin (cfs) Qmax (cfs) Tailwater Elev (ft) Highlighted Qtotal (cfs) Qpipe (cfs) Qovertop (cfs) Veloc Dn (ft/s) Veloc Up (ft/s) HGL Dn (ft) HGL Up (ft) Hw Elev (ft) Hw/D (ft) Flow Regime Wednesday, Sep 4 2024 = 4.93 = 4.93 = (dc+D)/2 = 4.93 = 4.93 = 0.00 = 2.11 = 4.34 = 776.39 = 776.41 = 776.72 = 0.55 = Inlet Control H-0490 tnl 13.32 780.00 78369 78100 279.60 72960 ar 0 10 20 30 C' cut CG M 40 50 60 HGL 70 80 Ein6e k 90 190 110 120 130 140 150 160 170 Hewn IN 1437 037 7.32 G3, -0..63 3.63 0 0 N o Qco u7 La o ct oa II1- N N i,-) N O 0 00 �> '� "0r o 7- 1-Z N N U II PROPOSED C.)� II (,) ,„ mil LL I- zal 8' WATER DIP MAIN E 18" RCP Ni STORM SEWER 24" 1II © • r125LF HORIZONTAL SCALE: 1 "=40' VERTICAL SCALE: 1 "=4' 0+00 1+00 2+00 40 GRAPHIC SCALE 0 20 40 80 EXHIBIT A REVISED IMPACT #6 160 800 790 780 770 760 ( IN FEET ) 1 inch = 40 ft. Culvert Report Hydrarlow Express Extension for Autodesk® Civil 3D® by Autodesk, Inc. Culvert DD Invert Elev Dn (ft) Pipe Length (ft) Slope (%) Invert Elev Up (ft) Rise (in) Shape Span (in) No. Barrels n-Value Culvert Type Culvert Entrance Coeff. K,M,c,Y,k Embankment Top Elevation (ft) Top Width (ft) Crest Width (ft) ant 01 = 769.00 = 125.00 = 3.10 = 772.88 = 42.0 = Circular = 42.0 = 1 = 0.012 = Circular Concrete = Square edge w/headwall (C) = 0.0098, 2, 0.0398, 0.67, 0.5 = 790.00 = 30.00 = 30.00 Guinn 00 Calculations Qmin (cfs) Qmax (cfs) Tailwater Elev (ft) Highlighted Qtotal (cfs) Qpipe (cfs) Qovertop (cfs) Veloc Dn (ft/s) Veloc Up (ft/s) HGL Dn (ft) HGL Up (ft) Hw Elev (ft) Hw/D (ft) Flow Regime Wednesday, Jun 192024 = 45.10 = 45.10 = Normal = 45.10 = 45.10 = 0.00 = 15.06 = 7.51 = 770.22 = 774.97 = 776.01 = 0.89 = Inlet Control 773 CO 30.13 18.13 8.13 10 20 CI oul Culvert Bete k linen let -3,8111 PROPOS�o 8' DIP WATER MAIN � N N -) b oo• HW DD-2 -THROAT=776.70' 42" II rn co STORM 15" RCP SEWER INV OUT-772.87' o Q II 0 0 = Z 5 = 1- > Z „ RGP 15' RIP RAP TO BE EMBEDDED IN STREAM BED EXISTING 3:1 SLOPE TO REMAIN HORIZONTAL SCALE: 1 "=40' VERTICAL SCALE: 1 "=4' 0+00 1+00 2+00 SEPARATION REQUIREMENTS SEWER LINES CROSSING WATER MAINS SHALL MAINTAIN A MINIMUM SEPARATION OF 18" VERTICALLY. WHERE IT IS IMPOSSIBLE TO MAINTAIN THE PRESCRIBED 18 INCHES OF VERTICAL SEPARATION, THE WATER LINE SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE AND THE SEWER LINE SHALL BE CONSTRUCTED TO WATER SYSTEM STANDARDS AND PRESSURE TESTED TO A MINIMUM OF 150 PSI IN ACCORDANCE WITH THE SCDHEC STANDARDS. GRAVITY SEWER CROSSING STORM DRAINS SHALL MAINTAIN A MINIMUM VERTICAL SEPARATION OF12". WHEN CROSSING SEPARATION IS LESS THAN 18"#57 STONE SHALL BE INSTALLED BETWEEN THE STORM DRAIN INVERT AND THE GRAVITY SEWER INVERT. .` NCAR/, � 0 ��',y RY'% NGINE`��,V`���• ' 9-5-24 PRELIMINARY SEPTEMBER 5, 2024 FOR REVIEW ONLY NOT FOR CONSTRUCTION M oo O 0 L) z E M O • 00 tO czj W'• O a DEC LAN HUNTERSVILLE HAMBRI GH T RD HUNTERSVILLE, NORTH CAROLINA MECKLENBURG COUNTY JOB NUMBER 2018-28 CO 0 BAH I Date A i~ A REVISIONS 0 DESCRIPTION d z C-5.11