Loading...
HomeMy WebLinkAboutWQCS00349_Renewal (Application)_20241007Town of Gilsonville Department of Public Works 1236 Springwood Church Rd. Gibsonville, NC 27249 Office: (336) 449-7188 email: publicworks@gibsonville.net Fax: (336) 449-7949 To: NCDEQ-DWR Water Quality Permitting Section PERCS UNIT Re: Wastewater collection system Permit Renewal For WQCS00349 Greetings, 9/23/2024 RECEIVED OCT 07 2024 NCDEQ/DWR/NPDES The Town of Gibsonville requests renewal of its wastewater collection system permit WQCS00349. Enclosed with this packet is the following information: Application, Pump station list, High priority line list, and Annual budget for collection system, Capital improvement plan, Response action plan, Contingency plan and comprehensive collection system map. If you have any questions or concerns please contact me. Sincerely, jo"� �A James R Elliott, Gibsonville Public Works Director cc: R. Benjamin Baxley, Gibsonville Town Manager State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T.0400 — SYSTEM -WIDE WASTEWATER COLLECTION SYSTEMS Division of Water Resources INSTRUCTIONS FOR FORM CSA 04-16 & SUPPORTING DOCUMENTATION Documents shall be prepared in accordance with 15A NCAC 02T .0100, 15A NCAC 02T .0400, and all relevant Division Policies. Failure to submit all required items will necessitate additional processing and review time. For more information, visit the System -wide Collection System Permitting website: General — When submitting an application to the Municipal Permitting Unit, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. The copy may be submitted in digital format. A. Cover Letter OCT 07 ?074 g Submit a cover letter listing all items and attachments included in the permit application package B. No Application Fee Required NCDEQ/DWR/NPDES ➢ No application fee is necessary. The permittee will be billed an annual fee upon issuance of the permit ➢ The appropriate annual fee for systemwide wastewater collection system permits may be found at: ➢ Annual Non-Dischar eg Fees C. System -Wide Wastewater Collection System (FORM: CSA 04-16) Application: g Submit the completed and appropriately executed System -wide Wastewater Collection System (FORM: CSA 04- 16) application. Any unauthorized content changes to this form shall result in the application package being returned. If necessary for clarity or due to space restrictions, attachments to the application may be made, as long as the attachments are numbered to correspond to the section and item to which they refer. ❑ If the Applicant Type in Section 1.3 is a Privately -Owned Public Utility, provide the Certificate of Public Convenience and Necessity (CPCN) from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the wastewater collection system, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. ❑ If the Applicant Type in Section 1.3 is a corporation or company, provide documentation if it is registered for business with the North Carolina Secretary of State. D. General Information: ➢ The Authorized signing official listed in Section I.4 should match with that of the Applicant certification page in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). ➢ NOTE - Public Works Directors are not authorized to sign this permit application, according to the rule, unless they are formally delegated. INSTRUCTIONS FOR APPLICATION CSA 04-16 & SUPPORTING DOCUMENTATION Page 1 of E. Summary of Attachments Required: ® Instruction A: Cover Letter ® Instruction C: Application ❑ Instruction C: Ownership Documentation (i.e. CPCN) (If necessary) ❑ Instruction D: Delegation Letter (If necessary for signing official) ® Section IV.3 Pump Station List ® Section IVA High Priority Lines List ® Section VA Annual Budget for Collection System (Updated and Approved) ® Section V.6 Capital Improvement Plan (Updated and Approved) ® Section VI.2 Response Action Plan ® Section VIA Contingency Plan ® Section VI.6 Comprehensive Collection System Map ❑ Section VII Note Any Potential Compliance Issues THE COMPLETED APPLICATION PACKAGE, INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO: NCDEQ-DWR Water Quality Permitting Section MUNICIPAL PERMITTING UNIT By U.S. Postal Service: BV Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 N. SALISBURY ST. Suite 925 RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 707-3601 TELEPHONE NUMBER: (919) 707-3601 INSTRUCTIONS FOR APPLICATION CSA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 5 1. APPLICANT INFORMATION: 1. Applicant's name (Municipality, Public Utility, etc): Town of Gibsonville 2. Facility Information: Name: Town of Gibsonville Collection System Permit No.: WQCS00349 3. Applicant type: ®Municipal ❑ State ❑ Privately -Owned Public Utility ❑ County ❑ Other: 4. Signature authority's name: R. Bejamin Baxley per 15A NCAC 02T .0106(b) Title: Town Manager 5. Applicant's mailing address: 129 W. Main St City: Gibsonville State: NC Zip: 27249-_ 6. Applicant's contact information: Phone number: 3( 36) 449-4144 Fax number: Q& 449-4196 Email address: bbaxley(a gibsonville.net H. CONTACT/CONSULTANT INFORMATION: 1. Contact Name: James R Elliott 2. Title/Affiliation: Public Works Director 3. Contact's mailing address: 129 W. Main St 4. City: Gibsonville State: NC Zip: 27249-_ 5. Contact's information: Phone number: (336) 449-7188 Fax number: 3(6 449-7949 III. GENERAL REQUIREMENTS: Email address: relliottagibsonville.net L New Permit or Premit Renewal? ❑ New ® Renewal 2. County System is located in: Guilford/Alamance County 3. Owner & Name of Wastewater Treatment Facility(ies) receiving wastewater from this collection system: Owner(s) & Name(s): City of Burlington East side WWTF and South sode WWTF 4. WWTF Permit Number(s): NCO023868 and NCO023876 5. What is the wastewater type? 100 % Domestic or 0 % Industrial (See 15A NCAC 02T .0103(20)) Is there a Pretreatment Program in effect? ❑ Yes or ® No 6. Wastewater flow: 0.709 MOD (Current average flow of wastewater generated by collection system) 7. Combined permitted flow of all treatment plants: 1.55 MGD 8. Explain how the wastewater flow was determined: ❑ 15A NCAC 02T .0114 or ® Representative Data 9. Population served by the collection system: 9721 IV. COLLECTION SYSTEM INFORMATION: 1. Line Lengths for Collection System: Sewer Line Description Length Gravity Sewer 54.3 miles Force Main 0.44 miles Vacuum Sewer 0 miles Pressure Sewer 0 miles APPLICATION CSA 04-16 Page 3 of 5 2. Pump Stations for Collection System: Pump Station Type Number Simplex Pump Stations(Serving Single Building) 0 Simplex Pump Stations(Serving Multiple Buildings) 0 Duplex Pum Stations 3 3. Submit a list of all major (i.e. not simplex pump station serving a single family home) pump stations. Include the following information: ➢ Pump Station Name ➢ Physical Location ➢ Alarm Type (i.e. audible, visual, telemetry, SCADA) ➢ Pump Reliability (Can convey peak hourly wastewater flow with largest single pump out of service) ➢ Reliability Source (permanent/portable generator, portable pumps) ➢ Capacity of Station (Pump Station Capacity in GPM) 4. Submit a list of all high priority lines according per 15A NCAC 02T .0402(2) known to exist in the collection system. Head the list with "Attachment A for Condition V(4)" and include the system name. ➢ Use the same line identification regularly used by the applicant ➢ Indicate type of high priority line (i.e. aerial), material and general location V. COLLECTION SYSTEM ADMINISTRATION: I. Provide a brief description of the organizational structure that is responsible for management, operation and maintenance of the collection system. The Gibsonville Mayor and Board of Aldermen appoint a town manager (Council -Manager form of government). The town manager is responsible for hiringall Il department heads including the public works director. The public works director is responsible for the management. operation and maintenance of the collection system through provided resources (financial and oersonnel). 2. Indicate the current designated collection system operators for the collection system per 15A NCAC 08G.0201 Main ORC Name: James R Elliott Jr Certification Number: 26232 Back -Up ORC Name: Frank Richard Wade Certification Number: 1000005 See the "WOCS Contacts and ORC Report" for a current listing of the ORC(s) the Division has on file for WQCS permit 3. Approximate annual budget for collection system only: $ 2,637,792 4. Submit a copy of your current annual budget. 5. Approximate capital improvement budge for the collection system only: S 370,000 6. Submit a copy of your current capital improvement plan. 7. Is this collection system currently a satellite system ® Yes or ❑ No 8. Do any satellite systems discharge to this collection system ❑ Yes or ® No (If yes complete table below) Complete for Satellite Systems that have a flow or capacity greater than 200,000 GPD (Average daily flow) 9. List any agreements or ordinances currently in place to address flows from satellite systems: The town has a satellite agreement with the Town of Whitsett to accept wastewater from a residential neighborhood currently under construction. The collection system has not vet been completed so no wastewater is currently being accented from Whitsett APPLICATION CSA 04-16 Page 4 of 5 VI. COLLECTION SYSTEM COMPLIANCE: 1. Is a Response Action Plan currently in place ® Yes or ❑ No 2. If Yes, submit a copy of the Response Action Plan or see table 6 below. 3. Is a pump station contingency plan currently in place? ® Yes or ❑ No 4. If Yes, submit a copy of the pump station contingency plan or see table 6 below. 5. Is a comprehensive collection system map currently in place? ® Yes or ❑ No 6. Submit a copy of the collection system map (CD or hardcopy) or indicate a schedule for completion 7. Thoroughly read and review the System -Wide Collection System Permit Conditions. Typically compliance schedules are only offered to NEW permit applicants and NOT permit renewals. Any compliance dates must be included within the permit prior to issuance or the permit holder will be found in violation upon inspection. Permit Condition Current Compliance? If no, Indicate a Compliance Date Typical Compliance Schedule 1(4) — Grease ordinance with legal authority to inspectlenforce ® Yes ❑ No 12 — 18 mo. I(5) — Grease inspection and enforcement program ® Yes ❑ No 12 — 18 mo. I(6) — Three to five year current Capital Improvement Plan. ® Yes ❑ No 12 — 18 mo. 1(8) — Pump station contingency plan ® Yes ❑ No 3 mo. I(9) — Pump station identification signs. ® Yes ❑ No 3 mo. I(11) — Functional and conspicuous audible and visual alarms. ® Yes ❑ No 3 — 6 mo. II(5) — Spare pumps for any station where one pump cannot handle peak flows alone (in a duplex station, the 2nd pump is the spare if pump reliability is met). ® Yes ❑ No 6 — 9 mo. 11(7) — Accessible right-of-ways and easements. ® Yes ❑ No 6 — 12 mo. II(9) — Response action plan with Items 9 (a — h). ® Yes ❑ No 3 mo. III(3) — Comprehensive collection system map ® Yes ❑ No 10% per year For conditions not listed, compliance dates are not typically offered. List any permit cofjE Gat dttt ek �r to applicant to meet (attach clarification if needed): YYY OCT 07 2024 VIL APPLICANT'S CERTIFICATION per 15A NCAC 02T .0106(b): I, R. Benjamin Baxley attest that this application for Town of bjGQFeQ/ D W R/ N P D ES (Signature Authority's Name & Title from Item 1.4) (Facility name from Item 1.1) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. l Signature: I Date: APPLICATION CSA 04-16 Page 5 of 5 Attachment A for IV.3 Town of Gibsonville Town of Gibsonville Pump Station List Pump Station Name: Sullivan Ct Location: 214 Sullivan Ct., Gibsonville, NC Alarm Type: Audible, Visual, Telemetry Pump Reliability: Yes (Can convey peak hourly wastewater flow with largest single pump out of service) Reliability Source: Portable Generator with quick connect for this station Capacity of Station: 0.052 MGD Design Capacity (36 gpm) Pump Station Name: Scott Drive Location: 614 Scott Dr., Gibsonville, NC Alarm Type: Audible, Visual, Telemetry Pump Reliability: Yes (Can convey peak hourly wastewater flow with largest single pump out of service) Reliability Source: Portable Generator with quick connect for this station Capacity of Station: 0.058 MGD Design Capacity (40 gpm) Pump Station Name: Broad St. Location: 708 Broad St. Gibsonville NC Alarm Type: Audible, Visual, Telemetry Pump Reliability: Yes (Can convey peak hourly wastewater flow with largest single pump out of service) Reliability Source: Permanent onsite generator Capacity of Station: 0.230 MGD Design Capacity (160 gpm) Attachment A for condition IV.4 Town of Gibsonville Town of Gibsonville High Priority Lines Aerial Lines: Sewer line at creek crossing on Steele St. (200 Block) Sewer line at creek crossing on Hwy 70 near Hutson Mobile Home Park Sewer line at creek crossing on First St outfall near manhole BC354 Sewer line at creek crossing on Hwy 61 N. entering TC324 Sub -waterway crossing lines: Travis Creek Outfall: Between manholes TC20 and TC21 At manhole TC24 Between manholes TC25 and TC26 Between manholes TC29 and TC30 Between manholes TC304 and TC305 At manhole TC32 1240 Springwood Church Road — Between Manholes BC177-BC176 Stream Crossing between Hwy 70 and Walnut Crossing Drive — Between Manholes BC125 — BC124 Carson Farms Sewer Outfall — Between Manholes BC2 - BC3 Brittnev Court Outfall— Between Manholes BC416— BC417 Behind 1306 Lashley Park Drive — Between Manholes BC422— BC432 Woodlawn Street Outfall— Between Manholes BC450— BC451 Other Lines that are not in public view, that have had issues in the past: Outfall on the dead end of Cummings Street Outfall line from Joyner St. to the Broad St lifts station Attachment Afor condition lV.4 Town ofGibsonville Outfall line off of First St. Outfall line between Joyner and Lewis St. Siphons: None Line Parallel to stream banks that are subject to eroding: Outfall line from Dick St. to Church St. Lines contacting surface waters: None Gibsonville staff is still evaluating the system to identify more high priority lines. Attachment A - Section VA FY2025 ADOPTED - BUDGET - EXPENDITURES EXPENDITURES SEWER EXPENSES Adopted-2025 SALARIES 222,485 OVERTIME 6,000 FICA 17,020 RETIREMENT 30,350 GROUP INSURANCE 43,469 401 K 11,109 SUPPLIES & MATERIALS 26,000 UNIFORMS 4,000 GAS/OIL 13,000 TIRES 2,000 SAFETY 1,500 TRAVEL & TRAINING 1,500 CELL PHONES 700 UTILITIES 10,000 BURLINGTON SEWER FEES 810,000 ELON SEWER FEES 1,044,000 M&R BLDGS/GROUNDS 6,500 M & R EQUIPMENT 5,000 M & R VEHICLE 3,000 MISCELLANEOUS 60,000 INSURANCE 14,000 DUES & SUBSCRIPTIONS 4,000 WATER METERS (CAP. OUTLAY) 50,000 CONTRACTED SERVICES 104,000 DEBT SERV 141,853 Reserve for Short Lived Assets per USDA 6,306 2,637,792 (61) - SEWER FUND 2,637,792 Page 122 F-lrr:l�Jl 1�W.&MMM7%TOILTA j , AMYAI inaoonvGnaMT pi AN.(f7pl SIIMMARY Icontinuedl d Primary Funding Total Capital oa `tepartment Project Source FY 2025 FY 2026 FY 2027 FY 2028 FY 2029 Cost !LibraN Library Debt Financing - 9,000,000 - - 9,000,000 Library Total 1 9,000,000 9,000000 General Fund CIP TotalL 1 1 2,177,000 1 4,326,000 1 17,083,000 1 2,995,000 1 405,000 27,311,000 Water New Water Tank Multi Source 1 2,500,000 1 2,500,000_1 2000,000 7,000,000 Service Truck water,sewer, street) Fund Balance 25,000 - - 25,000 Dump Truck (shared) Fund Balance 25,000 25,000 50,000 NC Hwy 61 Waterline Connector Multi Source 2,000,000 1 2,000,000 1 1,000,000 5,000,000 Water Total 4,500,000 1 4,550,000 1 3,000,000 1 25,000 I - I 12,07rA00 Sewer Dump Truck (shared) Fund Balance - 25,000 25,000 50,000 Service Truck (water,sewer, street) Fund Balance 25,000 - 25,000 Scott Drive Lift Station Rehab Fund Balance 25,000 - - 25,000 Trencher Fund Balance 10,000 - - 10,000 Broad Street Lift Station Rehab Fund Balance 25,000 - 25,000 Sullivan Court Lift Station Rehab Fund Balance - 20,000 20,000 Skid Steer Fund Balance 30,000 30,000 Sewer Total 1 85,000 25,000 45,000 30,000 185,000 Water & Sewer Total I 1 1 4,500,000 1 4,635,000 1 3,025,D00 1 70,000 1 30,000 1 12,260 000 CIP Grand Total I 1 1 6,677,000 1 8,961,000 1 20,108,000 1 3,065,000 1 435,000 39,571,000 Attachment A — Section VI.2 TOWN OF GIBSONVILLE SEWER SPILL RESPONSE PLAN Response Action Plan January 1, 2014 Revised July 30, 2015 Revised August 12, 2024 TOWN OF GIBSONVILLE SEWER SPILL RESPONSE PLAN PROCEDURES QUALIFIED AND ON CALL PERSONNEL ARE TO BE AVAILABLE TO MAKE ON SITE ASSESSMENTS OF A SPILL, OR SEWER EMERGENCY WITHIN ONE HOUR UPON NOTIFICATION. >AFTER NOTIFICATION PERSONNEL WILL INVESTIGATE SPILL TO DETERMINE THE PROBLEM AND CALL NECESSARY HELP< >NOTIFY ORC OR BACKUP ORC < >SPILL (IF NECESSARY) WILL BE REPORTED TO THE DIVISION OF WATER QUALITY WITHIN 24 HOURS< >PROCEED WITH REPAIRS TO ENSURE PROBLEM IS SOLVED< >NOTIFY AFFECTED RESIDENTS (IF APPLICABALE) < >DETERMINE AND EXECUTE PROPER CLEAN UP< >FOLLOW UP WITH SEWER SPILL RESPONSE FORM TO DWQ< >EMPLOYEES TO USE ALL SAFETY EQUIPMENT INCLUDING PERSONAL PROTECTIVE EQUIPMENT AS REQUIRED< THIS SEWER SPILL RESPONSE PLAN WILL BE AVAILABLE FOR ALL ESSENTIAL PERSONNEL ALL EMPLOYEES WILL BE MADE AWARE OF THESE PROCEDURES EMERGENCY CONTACT LIST NEED SOURCE Phone Number ORC Rob CELL (336) 516-4856 Public Works Director Elliott Backup ORC Ricky CELL (336) 516-4723 Asst. Public Works Dir. Wade Utility Superintendent Troy King CELL 336 840-6102 (336) 578-2931 UTILITY CONTRACTOR C&J UTILITIES CELL 336 214-0231 RENTAL EQUIPMENT UNITED RENTAL EMERGENCY (336)379-9757 M-F (336) 776-9800 DWQ AFTER HOUR OR WEEKEND 800-858-0368 POLICE OR FIRE 911 ELECTRICAL GUILFORD ELECTRIC CELL (336) 430-4634 ALLEN STEEL (336) 584-3756 ELECTRIC MOTORS CLAYTON ELECTRIC CLAPP SEPTIC TANK (336) 449-4390 SEPTIC TRUCK SERVICE CELL 336 516-4419 GORMAN RUPP (SCOTT DRIVE) & TSURUMI TENCARVA (336) 665-0250 (SULLIVAN COURT) FRANK LUCIUS CELL (336) 312-3266 PUMP PARTS UTILITY LOCATES USA ONE CALL 811 TOWING ANDREWS TOWING 336 449-4461 POWER DUKE ENERGY 800-578-0588 SAND STONE LUDD SUMMERS 336 669-2777 GAS COMPANY PIEDMONTGAS NATURAL (336) 227-0120 PUMPS AND PLUMBING WILLIE SAUL (336) 584-6324 PLUMBING W/S PARTS CAROLINA WATER (336) 622-6969 SYSTEMS MANAGED GENERATOR GENERATOR (336) 270-4824 SERVICES CROWN PUMP PARTS PUMPS, PARTS AND (704) 588-6250 SERVICE TOWN OF GIBSONVILLE EMERGENCY EQUIPMENT LIST THE FOLLOWING ITEMS ARE READILY AVAILABLE AT THE PUBLIC WORKS FACILITY AT 1236 SPRINGWOOD CHURCH ROAD BACKHOES DUMP TRUCKS BUCKET TRUCK SEWER JETTING EQUIPMENT VAC TRAILER SEWER T.V. CAMERA PORTABLE GENERATORS EMERGENCY LIGHTING MATERIALS FOR MOST REPAIRS SMOKE EQUIPMENT TRAFFIC CONTROL DEVICES PPE ALSO SAFETY EQUIPMENT ON HAND GAS MONITOR FRESH AIR FAN SAFETY TRIPOD HARNESSES SHORING BOX ETC I Attachment A — Section VIA TOWN OF GIBSONVILLE PUMP FAILURE CONTINGENCY PLAN January 1, 2014 Revised July 30, 2015 Revised August 12, 2024 Attachment A — Section VIA IN ACCORDANCE WITH OUR COLLECTION SYSTEM PERMIT, THE FOLLOWING IS A CONTINGENCY PLAN FOR PUMP FAILURE AT ALL OUR SANITARY LIFT STATIONS. ➢ FIRST THE MAINTENANCE PERSONNEL WILL DETERMINE THE NATURE OF THE PUMP FAILURE AND THE EXTENT OF REPAIRS NEEDED. ➢ MAINTENANCE PERSONNEL SHALL THEN NOTIFY THE ORC OR BACKUP ORC OF THE SITUATION ➢ IF NECESSARY, EMERGENCY EQUIPMENT WILL BE SET IN PLACE TO ENSURE THAT A SANITARY OVERFLOW DOES NOT OCCUR. ➢ IF IT IS DETERMINED THAT REPAIRS CAN BE MADE ON SITE, PERSONNEL WILL USE ALL SAFETY PROCEDURES INCLUDING LOCK OUT TAG OUT. ➢ MINOR REPAIRS SUCH AS DEBRIS REMOVAL OR MINOR PART REPLACEMENT WILL BE COMPLETED BY MAINTENANCE PERSONNEL. ➢ OTHER MAJOR REPAIRS SUCH AS MOTOR REPAIR AND MAJOR ELECTRICAL WORK SHALL BE COMPLETED BY A LOCAL CONTRACTOR IN A TIMELY MANNER. THERE ARE SOME SPARE PARTS AND EQUIPMENT THAT ARE MAINTAINED AT OUR LIFT STATIONS OR OUR WAREHOUSE, SUCH AS REPLACEMENT IMPELLERS AND CUTTER RINGS FLOATS AIR COMPRESSORS FOR BUBBLER SYSTEMS VARIOUS ELECTRICAL CONTROL DEVICES PORTABLE GENERATOR SOME PUMP REPLACEMENT PARTS Attachment A — Section VIA EMERGENCY CONTACT LIST NEED SOURCE Phone Number ORC Rob CELL (336) 516-4856 Public Works Director Elliott Back upORC Ricky CELL (336)516-4723 Asst. Public Works Dir. Wade Utility Superintendent Troy King CELL 336 840-6102 UTILITY C&) UTILITIES (336) 578-2931 CONTRACTOR CELL 336 214-0231 RENTAL EQUIPMENT UNITED EMERGENCY (336)379-9757 RENTAL M-F (336) 776-9800 DWQ AFTER HOUR OR WEEKEND 800-858-0368 POLICE OR FIRE 911 GUILFORD ELECTRICAL ELECTRIC CELL (336) 430-4634 ALLEN STEEL CLAYTON (336) 584-3756 ELECTRIC MOTORS ELECTRIC CLAPP SEPTIC (336) 449-4390 SEPTIC TRUCK TANK SERVICE CELL 336 516-4419 GORMAN RUPP (SCOTT DRIVE) & TENCARVA (336) 665-0250 TSURUMI (SULLIVAN FRANK LUCIUS CELL (336) 312-3266 COURT) PUMP PARTS UTILITY LOCATES USA ONE CALL 811 TOWING ANDREWS (336) 449-4461 TOWING POWER DUKE ENERGY 800-578-0588 SAND/STONE LUDD (336) 669-2777 SUMMERS GAS COMPANY PIEDMONT (336) 227-0120 NATURAL GAS PUMPS AND WILLIE SAUL (336) 584-6324 PLUMBING PLUMBING CAROLINA W/S PARTS WATER (336) 622-6969 SYSTEMS MANAGED GENERATOR GENERATOR (336) 270-4824 SERVICES CROWN PUMP PARTS PUMPS, PARTSr777 (704) 588-6250 AND SERVICE Attachment A — Section VIA SULLIVAN CT. LIFT STATION 214 SULLIVAN CT. THIS LIFT STATION CATCHES ABOUT 380' OF SEWER LINE WITH ONLY A FEW HOUSES ON IT. THE FORCE MAIN EMPTIES OUT IN A MANHOLE AT THE INERSECTION OF SULLIVAN CT. AND PARK DR. THEN GRAVITY FLOWS TO THE BROAD ST. LIFT STATION, INTO THE TOWN OF ELONS TRAVIS CREEK LIFT STATION, THEN INTO CITY OF BURLINGTON'S SYSTEM (EAST WWTP) FEATURESINCLUDE ➢ AUDIO AND VISUAL ALARMS AND TELEMETRY ➢ POSTED EMERGENCY CONTACT INFORMATION ➢ CONNECTIONS AND MANUAL TRANSFER SWITCH FOR PORTABLE GENERATOR ➢ FLOAT STYLE LEVEL CONTROLS ➢ (2) 3 HP CUTTER STYLE SUBMERSIBLE PUMPS OTHER INFORMATION ➢ STATION IS VISITED 3 DAYS A WEEK TO ENSURE PROPER WORKING ORDER ➢ ALARMS TESTED MONTHLY ➢ MAINTENANCE PERFORMED AS NEEDED ➢ PREVENTATIVE MAINTENANCE (MAINLY CONTROL OF GREASE) AS NEEDED ➢ FLOATS AND ASSORTED ELECTRICAL PARTS ARE LOCATED AT OUR SPRINGWOOD WAREHOUSE ➢ REPLACEMENT PARTS AND PUMPS CAN BE OBTAINED AT TENCARVA IN GREENSBORO. A SPARE PUMP IS KEPT ON HAND AT PUBLIC WORKS. Attachment A — Section VIA SCOTT DR. LIFT STATION 614 SCOTT DR. THIS STATION CATCHES ABOUT 9200' OF SEWER LINE LOCATED ON THE SOUTHEASTERN PART OF GIBSONVILLE. THE FORCE MAIN EMPTIES OUT AT THE INTERSECTON OF MEADOW ST. AND PINE ST., SEWAGE THEN GRAVITY FLOWS TO OUR LITTLE BACK CREEK OUTFALL AND INTO CITY OF BURLINGTON'S SYSTEM. (SOUTH WWTP) FEATURESINCLUDE ➢ AUDIO AND VISUAL ALARMS AND TELEMETRY ➢ POSTED EMERGENCY CONTACT INFORMATION ➢ CONNECTIONS AND MANUAL TRANSFER SWITCH FOR PORTABLE GENERATOR ➢ BUBBLER SYSTEM FOR LEVEL CONTROLS ➢ HOUR METERS ON PUMPS BUT NO FLOW METER ➢ (2) 208 VOLTS 5 HP CUTTER STYLE SUBMERSIBLE PUMPS OTHER INFORMATION ➢ STATION IS VISITED 3 TIMES PER WEEK AND DATA RECORDED ➢ ALARMS TESTED MONTHLY ➢ MAINTENANCE PERFORMED AS NEEDED WITH BASIC PARTS ON HAND ➢ PREVENTATIVE MAINTENANCE (MAINLY CONTROL OF GREASE) AS NEEDED ➢ FLOATS AND ASSORTED ELECTRICAL PARTS ARE LOCATED AT OUR SPRINGWOOD WAREHOUSE ➢ REPLACEMENT PARTS AND PUMPS CAN BE OBTAINED AT TENCARVA IN GREENSBORO. A SPARE PUMP IS KEPT ON HAND AT PUBLIC WORKS. Attachment A — Section VIA BROAD ST. LIFT STATION 708 BROAD ST. THIS STATION CATCHES ABOUT 17,000' OF SEWER LINES LOCATED ON THE NORTHEASTERN SIDE OF GIBSONVILLE. THE FORCE MAIN EMPTIES OUT IN A MANHOLE AT THE INTERSECTION OF BROAD ST. AND WYRICK ST. FROM THIS POINT SEWER GRAVITY FLOWS TO ELON'S TRAVIS CREEK PUMP STATION, INTO CITY OF BURLINGTON'S SYSTEM. (EAST WWTP) FEATURES INCLUDE ➢ AUDIO AND VISUAL ALARMS AND TELEMETRY ➢ POSTED EMERGENCY CONTACT INFORMATION ➢ ONSITE GENERATOR ➢ HOUR METERS ON PUMPS BUT NO FLOW METER ➢ BUBBLER SYSTEM FOR LEVEL CONTROLS ➢ (2) CROWN FRAME PUMPS DRIVEN BY 7'/2 HP MOTORS OTHER INFORMATION ➢ STATION IS VISITED 3 TIMES PER WEEK AND DATA RECORDED ➢ ALARMS TESTED MONTHLY ➢ MAINTENANCE PERFORMED AS NEEDED WITH BASIC PARTS ON HAND ➢ PREVENTATIVE MAINTENANCE OIL, GREASE ETC. TWICE A YEAR OR AS NEEDED ➢ SPARE MOTOR AND BELTS LOCATED AT PUBLIC WORKS ➢ REPLACEMENT PUMPS AND PARTS CAN BE OBTAINED FROM PUMPS, PARTS AND SERVICE IN CHARLOTTE OR CAROLINA WATER SYSTEMS (CWS) Attachment A — Section VIA TOWN OF GIBSONVILLE EMERGENCY EQUIPMENT LIST THE FOLLOWING ITEMS ARE READILY AVAILABLE AT THE PUBLIC WORKS FACILITY BACKHOES DUMP TRUCKS BUCKET TRUCK SEWER JETTING EQUIPMENT VAC TRAILER SEWER T.V. CAMERA PORTABLE GENERATORS EMERGENCY LIGHTING MATERIALS FOR MOST REPAIRS SMOKE EQUIPMENT TRAFFIC CONTROL DEVICES PPE ALSO SAFETY EQUIPMENT ON HAND GAS MONITOR FRESH AIR FAN SAFETY TRIPOD HARNESSES SHORING BOX ETC Attachment A — Section VIA SULLIVAN CT. LIFT STATION GENERATOR HOOK UP SELECTOR SWITCH ON GENERATOR TO BE SET ON 208/120 VOLT USING CORD WITH TWIST CAM ENDS, HOOK ON END TO THE 30 AMP GENERATOR SOCKET ON THE CONTROL SIDE OF GENERATOR CRANK GENERATOR UP AND LET ENGINE LEVEL OFF HOOK OTHER END OF CORD TO THE INLET SOCKET NEAR TRANSFER SWITCH FLIP MANUAL TRANSFER SWITCH Attachment A — Section VIA BROAD ST. LIFT STATION GENERATOR HOOK UP GENERATOR OPERATION GENERATOR HAS AN AUTOMATIC TRANSFER SWITCH AND WITH THIS FEATURE THE OPERATION UNDER EMERGENCY CONDITIONS SHOULD NOT NEED ANY SPECIAL ATTENTION Contact Todd Palmer at Palmer Generator If needed (336) 270-4824 Attachment A — Section VIA SCOTT DR. LIFT STATION GENERATOR HOOK UP SELECTOR SWITCH TO BE IN 208/120 VOLTS USING CORD SET WITH COLORED ENDS BLACK, BLUE, RED AND WHITE HOOK UP AS FOLLOWS GENERATOR SIDE LI L2 L3 N GROUND TO TO TO TO TO BLACK RED BLUE WHITE GREEN STATION SIDE AT CONNECTOR BOX BLACK RED BLUE WHITE GREEN TO TO TO TO TO BLACK RED BLUE WHITE GREEN CRANK UP GENERATOR AND LET ENGINE LEVEL OUT PULL TRANSFER SWITCH TO GENERATOR POSITION