Loading...
HomeMy WebLinkAboutWQ0000088_Monitoring - 03-2024_20240603SUBMIT FORM ON YELLOW PAPER ONLY EPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: �1617 IVISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: (919) 7333221 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7-31-2023 Facility Name: Governors Club Non -Discharge WQ0000088 UIC Permit Name (if different): NPDES Other Facility Address: TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery Chapel Hill NC County Chatham ® Spray Field ❑ Remediation: Contact Person: Wesley Bishop Telephone#: 919-653-5760 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 4 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-1A Date sample collected: 3/26/2024 FIELD ANALYSES: WAS Well Depth: 45.03 ft. Well Diameter: 2 in. pH 6.9 units Temp. 16 °C DRY at Depth to Water Level: 24.67 ft. below measuring point Screened Interval: ft. to ft. Spec. Cond. µMhos time of sampling, Measuring Point is 0 ft. above land surface Relative M.P. Elevation: ft. Odor check Volume of water pumped/bailed before sampling: 1.6 gallons Appearance here: ❑ Samples for metals were collected unfiltered: ❑YES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 3/26/2024-4/9/2024 Laboratory Name: Waypoint Analytical Certification No. 10 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD mg/I Nitrite (NO2) as N mg/I Pb - Lead mg/I Coliform: MF Fecal <1 /100ml Nitrate (NO3) as N 0.15 mg/I Zn - Zinc mg/I Coliform: MF Total /100ml Phosphorus: Total as P 0.16 mg/I (Note. Use MPN method for highly turbid samples) Orthophosphate mg/I Other (Specify Compou en`tratiV, Units): 0 Dissolved Solids: Total 1700 mg/I AI - Aluminum mg/I YL� pH (when analyzed) 6.9 units Ba - Barium mg/I ,.l TOC 4.47 mg/I Ca - Calcium mg/1 Chloride 647 mg/I Cd - Cadmium mg/I OVM Arsenic mg/I Chromium: Total mg/I t W Grease and Oils mg/1 Cu - Copper mg/I ORGANICS: (by GC, GC/MS, HPLC) Phenol mg/I Fe - Iron mg/I (Specify test and method #. ATTACH LAB REPORT.) Sulfate mg/I Hg - Mercury( mg/I Report Attached? El Yes (1) ® No (0) Specific Conductance µMhos K - Potassium]UTU 22024 mg/I VOC method # Total Ammonia 0.35 mg/I Mg - Magnesium mg/I method # (Ammonia Nitrogen; NH3as N; Ammonia Nitrogen, Total) Mn -Manganese —mg/1 ,method # TKN as N mg/1 Ni - Nickel mg/I method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Wesley Bishop - Field Supervisor Permittee (or Authorized Aqent) Name and Title - Please print or type Siqnature of Pe ee (or Authorized Aqent) (Date) GW-59 Rev.1/2007 SUBMIT FORM ON YELLOW PAPER ONLY DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: (VISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 617 MAIL SERVICE CENTER, RALEIGH, NC 27699.1617 Phone: (919) 733-3221 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7-31-2023 Facility Name: Governors Club Non -Discharge WQ0000088 UIC Permit Name (if different): NPDES Other Facility Address: TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery Chapel Hill NC County Chatham ® Spray Field ❑ Remediation: Contact Person: Wesley Bishop Telephone#: 919-653-5760 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 4 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-3A Date sample collected: 3/26/2024 FIELD ANALYSES: WAS Well Depth: 44.56 ft. Well Diameter: 2 in. pH 6.2 units Temp. 15 eC DRY at Depth to Water Level: 25.12 ft. below measuring point Screened Interval: ft. to _ft. Spec. Cond. µMhos time of sampling, Measuring Point is 0 ft. above land surface Relative M.P. Elevation: ft. Odor check Volume of water pumped/bailed before sampling: 1.5 gallons Appearance here: Samples for metals were collected unfiltered: El YES ❑ NO and field acidified: ❑ YES ❑ NO u LABORATORY INFORMATION Date sample analyzed: 3/26/2024-4/9/2024 Laboratory Name: Waypoint Analytical Certification No. 10 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD mg/I Nitrite (NO2) as N mg/I Pb - Lead mg/I Coliform: MF Fecal <1 /100ml Nitrate (NO3) as N 0.04 mg/I Zn - Zinc mg/I Coliform: MF Total /100ml Phosphorus: Total as P 1.01 mg/I (Note. Use MPN method for highly turbid samples) Orthophosphate mg/I Other (Specify Compounds and Concentration Units): Dissolved Solids: Total 160 mg/1 Al - Aluminum mg/I pH (when analyzed) 6.2 units Ba - Barium mg/I TOC 4.56 mg/1 Ca - Calcium mg/I Chloride 20 mg/1 Cd - Cadmium mg/I Arsenic mg/l Chromium: Total mg/1 Grease and Oils mg/I Cu - Copper mg/I ORGANICS: (by GC, GC/MS, HPLC) Phenol mg/1 Fe - Iron mg/I (Specify test and method #. ATTACH LAB REPORT.) Sulfate mg/I Hg - Mercury mg/I Report Attached? ❑ Yes (1) ® No (0) Specific Conductance µMhos K - Potassium mg/I VOC method # Total Ammonia 0.18 mg/I Mg - Magnesium mg/I method # (Ammonia Nitrogen, NH, as N, Ammonia Nitrogen, Total) Mn -Manganese mg/I ,method # TKN as N mg/I Ni - Nickel mg/I method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Wesley Bishop - Field Supervisor Permittee (or Authorized Aqent) Name and Title - Please print or type Siqnature of Perm i a (or Authorized Aqent) (Date) GW-59 Rev.1/2007 SUBMIT FORM ON YELLOW PAPER ONLY EPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: Im IVISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: (919) 733-3221 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: 7-31-2023 Facility Name: Governors Club Non -Discharge WQ0000088 UIC NPDES Other Permit Name (if different): Facility Address: TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery Chapel Hill NC County Chatham ® Spray Field ❑ Remediation: Contact Person: Wesley Bishop Telephone#: 919-653-5760 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 4 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-7 Date sample collected: 3/26/2024 FIELD ANALYSES: WAS Well Depth: 30.21 ft. Well Diameter: 2 in. pH 7.0 units Temp. 16 eC DRY at Depth to Water Level: 24.0 ft. below measuring point Screened Interval: ft. to ft. Spec. Cond. µMhos time of Measuring Point is 0 ft. above land surface Relative M.P. Elevation: ft. Odor sampling, check Volume of water pumped/bailed before sampling: 0.5 gallons Appearance here: ❑ Samples for metals were collected unfiltered: DYES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 3/26/2024-4/9/2024 Laboratory Name: Waypoint Analytical Certification No. 10 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD mg/I Nitrite (NO2) as N mg/I Pb - Lead mg/I Coliform: MF Fecal <1 .0 /100ml Nitrate (NO3) as N <0.04 mg/I Zn - Zinc mg/I Coliform: MF Total /100ml Phosphorus: Total as P 4.87 mg/I (Note: Use MPN method for highly turbid samples) Orthophosphate mg/I Other (Specify Compounds and Concentration Units): Dissolved Solids: Total 700 mg/I Al - Aluminum mg/I Total Suspended Residue: 484 mg/I pH (when analyzed) 7.0 units Ba - Barium mg/I TOC 9.44 mg/I Ca - Calcium mg/I Chloride 54 mg/I Cd - Cadmium mg/I Arsenic mg/I Chromium: Total mg/I Grease and Oils mg/I Cu - Copper mg/I ORGANICS: (by GC, GC/MS, HPLC) Phenol mg/I Fe - Iron mg/I (Specify test and method #. ATTACH LAB REPORT.) Sulfate mg/I Hg - Mercury mg/I Report Attached? ❑ Yes (1) ® No (0) Specific Conductance µMhos K - Potassium mg/I VOC method # Total Ammonia <0.04 mg/I Mg - Magnesium mg/I method # (Ammonia Nitrogen; NH3as N. Ammonia Nitrogen, Total) Mn -Manganese mg/I ,method # TKN as N mg/I Ni - Nickel mg/I method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Wesley Bishop - Field Supervisor Permittee (or Authorized Aqent) Name and Title - Please print or type Siqnature of Permi a (or Authorized Aqent) (Date) GW-59 Rev.1/2007 SHRMIT FnRM nw YFI I nyy PAPFR nmi V GROUNDWATER QUALITY MONITORING: DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES (VISION OF WATER QUALITY -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phons: (919) 733-3221 FACILITY INFORMATION Please Prfnt Clearly orType PERMIT Number: Expiration Dale: 7-31-2023 Facility Name: Governors Club Non -Discharge W00000088 UIC NPDES Other Permit Name (if different): Facility Address: TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery Chapel Hill NC County Chatham Spray Field ❑ Remediation: Contact Person: Wesley Bishop Telephone#: 919-653-5760 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: No. of wells to be sampled: 4 ❑ Water Source Heat Pump ❑ Other: frcm Porrr�l SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): MW-9 Date sample collected: 3/2612024 FIELD ANALYSES: WAS Well Depth: 32.09 ft. Well Diameter: 2 in. pH 7.3 units Temp. 15 aC DRY at Depth to Water Level: 2.50 ft. below measuring point Screened Interval: ft. to ft. Spec. Cond. }(Mhos time of Measuring Point is 0 ft. above land surface Relative M.P. Elevation: ft. Odor sampling, check Volume of water pumpedlbailed before sampling: 5 gallons Appearance here: ❑ Samples for metals were collected unfiltered: DYES ❑ NO and field acidified: ❑ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 11/30/23-12/13124 Laboratory Name: Waypoint Analytical Certification No. 10 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD mg/I Nitrite (NO2) as N mgll Pb - Lead mg/I Coliform: MF Fecal <1 ,0 /loom] Nitrate (N0,,) as N <0,04 mg/1 Zn - Zinc mg11 Coliform: MF Total /100ml Phosphorus: Total as P 0.50 mg/I (Note: Use MPN nwthad for hlghlyturbid carrplos) Orthophosphate mgll Other (Specify Compounds and Concentration Units): Dissolved Solids: Total 720 mgil Al - Aluminum mg/i Total Suspended Residue: 102 rngll pH (when analyzed) 7.3 units Ba - Barium mg/I TOC 3.74 mgll Ca - Calcium mg/I Chloride 147 mg11 Cd - Cadmium mg/I Arsenic mg/I Chromium: Total mgll Grease and Oils mg/I Cu - Copper mgli ORGANICS: (by GC, GC30S, HPLC) Phenol mg/I Fe - Iron mg/I (Specify test and method #. ATTACH LAB REPORT.) Sulfate mg/I Hg - Mercury mg/I Report Attached? ❑ Yes (1) ® No (0) Specific Conductance pMhos K - Potassium mg/I VOC method # Total Ammonia <0.04 mg/I Mg - Magnesium mg/1 method # (Ammonla Nitrogen; NH3as N; Ammonia Nitrogen, Total) Mn -Manganese mg/l ,method # TKN as N mgll Ni - Nickel mg/l method # For Rernedlation Systems Only • Total Reports): Influent • . • I certify that, to the best of my knowledge and belief, the information submitted in this report Is true, accurate, and complete, and that the laboratory analytical data was produced using approved methods of analysis by a DWQ-certified laboratory. I am aware that there are significant penalties for submitting false Information Includina the DOSSIbllitY of fines and Imprisonment for knowing violations. Wesley Bishop - Field Supervisor Perrnitlee (or Authorized Agenl) Namo and Title - Please print or type Signature of Permiltee (or Authorized Aqent) (Date) GW-59 Rev.112007 IVERSTILITIES We are TRU to our customers! August 7, 2024 Department of Environmental Quality Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: Groundwater Monitoring Land Application of Class B Residuals Permit #WQ0001793 Dear Groundwater Staff: Attached are forms GW-59 and GW-59A with results from the July 2024 groundwater monitoring required by the City of Gastonia / Two Rivers Utilities Land Application of Class B Residuals Permit #WQ0001793. Monitoring well MW-6 was above the interim groundwater standard for ammonia which has been an ongoing issue. The pH of all wells were both below the 6.5 standard units which has been typical for measurements at these sites. If you have any questions or if I may be of assistance regarding this report please contact me at 704-214-9145 or davids@tworiversutilities.com. Sincerely, David Shellenbarger Assistant Division Manager —Compliance Wastewater Treatment Division Enclosures Certified Mail: 70161370 0000 8337 7054 c c.� a N O N