Loading...
HomeMy WebLinkAboutWQCSD0786_Incident 202402658_5 Day Report_20240801State of North Carolina vollk Department of Environment and Natural Resources Mir D-WIRW Division of Water Resources Collection System Sanitary Sewer Overflow Reporting Form Division of Water Resources Form CS-SSO PART I: This form shall be submitted to the appropriate DWR Regional Office within five business days of the first knowledge of the sanitary sewer overflow (SSO). Permit Number: WQCSD0786 (WQCS# if active, otherwise use WQCSD#) Facility: Cross Creek MHP Incident #: Owner: Aqua North Carolina Region: Raleigh City: Knightdale County: Wake Source of SSO (check applicable): ® Sanitary Sewer ❑ Pump Station / Lift Station SPECIFIC location of the SSO (be consistent in description from past reports or documentation - i.e. Pump Station 6, Manhole at Westall & Bragg Street, etc.): Manhole at WWTP Manhole #: Latitude (degrees/minute/second): 35.75107 Longitude (degrees/minute/second): 78.50614 Incident Started Dt: 9/27/2024 Time: 2:40pm Incident End Dt: 9/27/2024 Time: 3:20pm (mm-dd-yyyy) (hh:mm) AM/PM (mm-dd-yyyy) (hh:mm) AM/PM Estimated volume of the SSO: 1000 gallons Estimated Duration (round to nearest hour): 1 hour(s) Describe how the volume was determined: Estimated from what was seen Weather conditions during the SSO event: Cloudy Did the SSO reach surface waters? ❑ Yes ® No ❑ Unknown Volume reaching surface waters: gallons Surface water name: Did the SSO result in a fish kill? ❑ Yes ® No ❑ Unknown If Yes, what is the estimated number of fish killed? SPECIFIC cause(s) of the SSO: ❑Severe Natural Conditions ® Grease [-]Roots ❑Inflow & Infiltration ❑Pump Station Equipment Failure ❑ Power Outage ❑Vandalism ❑ Debris in line ❑Pipe Failure (Break) ❑Other (Please explain in Part ll) 24-hour verbal notification (name of person contacted): Joe Myer ®DWR ❑Emergency Management Date (mm-dd-yyy): 9/27/2024 Time: (hh:mm AM/PM): 5:30pm Per G.S. 143-215.1 C(b), the owner or operator of any wastewater collection system shall: In the event of a discharge of 1,000 gallons or more of untreated wastewater to the surface waters of the State, issue a press release to all print and electronic news media that provide general coverage in the county where the discharge occurred setting out the details of the discharge. The press release shall be issued within 24 hours after the owner or operator has determined that the discharge has reached surface waters of the State. In the event of a discharge of 15,000 gallons or more of untreated wastewater to the surface waters of the State, publish a notice of the discharge in a newspaper having general circulation in the county in which the discharge occurs and in each county downstream from the point of discharge that is significantly affected by the discharge. The Regional Office shall determine which counties are significantly affected by the discharge and shall approve the form and content of the notice and the newspapers in which the notice is published. WHETHER OF NOT PART II IS COMPLETED A SIGNATURE IS REQUIRED SEE PAGE 13 Form CS-SSO Page 1 In order tosubmit aclaim for justification of an SSO.you must use Part Uof form CS-SSO with additional documentation as necessary. DWR staff will review the justification claim and determine if enforcement action is appropriate. PART III: ANSWER THE FOLLOWING QUESTIONS FOR EACH RELATED CAUSE CHECKED IN PART I OF THIS FORM AND INCLUDE THE APPROPRIATE DOCUMENTATION ASREQUIRED URDESIRED COMPLETE ONLY THOSE SECTONS PERTAINING TO THE CAUSE OF THE SSO AS CHECKED IN PART I (In the check boxes below, NA = Not Applicable and NE = Not Evaluated) AHARDCOPYOF THIS FORM SHOULD BE SUBMITTED TO THE APPROPRIATE DWR REGIONAL OFFICE UNLESS |SHAS BEEN SUBMITTED ELECTRONICALLY THROUGH THE ONLINE REPORTING SYSTEM Form CS-SSO Page 2 Severe Natural Conditions (hurricane, tornado, etc.) Describe the "severe natural condition" in detail: How much advance warning did you have and what actions were taken in preparation for the event? Comments: Form CS-SSO Page 3 Grease (Documentation such as cleaning, inspection, enforcement actions, past overflow reports, educational material and distribution date, etc. should be available upon request.) When was the last time this specific line (or wet well) was cleaned? 2022 Do you have an enforceable grease ordinance that requires new or retrofit of grease traps/interceptors? ❑ Yes ® No ❑ NA ❑ NE Have there been recent inspection and/or enforcement actions taken on near- by restaurants or other nonresidential grease contributors? ❑ Yes ® No ❑NA ❑ NE Explain: No restaurants in this system. Residental Only Have there been other SSOs or blockages in this areas that were also caused by grease ❑ Yes ® No ❑NA ❑ NE When? If yes, describe them: Have cleaning and inspections ever been done at this location? ® Yes ❑ No ❑NA ❑ NE Explain. Have educational material about grease been distributed in the past? ® Yes ❑ No ❑NA ❑ NE When: This year we sent out the info in April and will be sending it out again in October. and to whom: Aqua sends educational material about grease twice a year to all customers. Explain: If the SSO occurred at a pump station, when was the wet well and pumps last checked for grease accumulation: Were the floats clean? ❑ Yes ❑ No ❑NA ❑ NE Comments: Form CS-SSO Page 4 Roots Do you have an active root control program on the line / area in question? ❑ Yes ❑ No ❑NA Describe: Have cleaning and inspections ever been increased at this location because of roots? ❑ Yes ❑ No ❑NA Explain: What corrective actions have been accomplished at the SSO location (and surrounding system if associated with the SSO)? What corrective actions are planned at the SSO location to reduce root intrusion? Has the line been smoke tested or videoed within the past year? If Yes, when? Comments: ❑ Yes ❑ No ❑NA MMS R® RM Form CS-SSO Page 5 Inflow and Infiltration Am(Special or El Yes �� [� No � �NE [��NA �0 inany permit that addresses N? Explain if Yes: What corrective actions have been taken to reduce or eliminate I & I related overflows this spill location within the last year? Has there been any flow studies Vm determine 18 problems in the Fl You [7 No RNA El NE collection system okthe SSOlocation? |fYes, when was the study completed and what actions did itrecommend? Has the line been smoke tested orvideoodwithin the past year? El Yes RNu RNA NE |fYes, when and what actions are necessary and the status ofsuch actions: Are there //| related projects inyour Capital Improvement Plan? Fl Yes rl No FINA R NE If Yes, explain: Have there been any grant orloan applications for Nreduction projects? RYea FlNn RNA RNE If Yes, explain: Doyou suspect any major sources ofinflow orcross connections RYes ElNo RNA RNE with storm sewers? If Yes, explain: Have all lines contacting surface waters inthe SSOlocation and upstream El Yes EJ No RNA R NE been inspected recently? If Yes, explain: What other corrective actions are planned to prevent future 1/1 related SSOs at this location? Comments: Form CS-SSO Page 6 Pump Station Equipment Failure (Documentation of testing records, etc should be provided upon request) What kind of notification/alarm systems are present? Auto-dialer/telemetry (one-way communication) ❑ Yes Audible ❑ Yes Visual ❑ Yes SCADA (two-way communication) ❑ Yes Emergency Contact Signage ❑ Yes Other ❑ Yes If Yes, explain: Describe the equipment that failed: What kind of situations trigger an alarm condition at this station (i.e. pump failure, power failure, high water, etc.)? Were notification/alarm systems operable? ❑ Yes ❑ No ❑NA ❑ NE In no, explain: If a pump failed, when was the last maintenance and/or inspection performed? What specifically was checked/maintained? If a valve failed, when was it last exercised? Were all pumps set to alternate? ❑ Yes ❑ No ❑NA ❑ NE Did any pump show above normal run times prior to and during the SSO event? ❑ Yes ❑ No ❑NA ❑ NE Were adequate spare parts on hand to fix the equipment Was a spare or portable pump immediately available? If a float problem, when were the floats last tested? How? If an auto -dialer or SCADA, when was the system last tested? How? Comments: ❑ Yes ❑ No ❑NA ❑ NE ❑ Yes ❑ No ❑NA ❑ NE Form CS-SSO Page 7 Power outage (Documentation of testin_q, records, tec., should be provided of alternative power source upon What isyour alternate power orpumping source? Did it function properly? Fl Yes [l No [:INA n NE Describe? When was the alternate power nrpumping source last tested under load? If caused by a weather event, how much advance warning did you have and what actions were taken to prepare for the event? Comments: Form CS-SSO Page 8 Vandalism Provide police report number: Was the site secured? ❑ Yes ❑ No If Yes, how? Have there been previous problems with vandalism at the SSO location? If Yes, explain: What security measures have been put in place to prevent similar ❑ Yes ❑ No occurrences in the future? Comments: WE, AMS OM Form CS-SSO Page 4 Debris in line (Rocks, sticks, rags and other items not allowed in the collection system, etc.) What type of debris has been found in the line? Suspected cause or source of debris: Are manholes in the area secure and intact? When was the area last checked/cleaned? Have cleaning and inspections ever been increased at this location due to previous problems with debris? Explain: Are appropriate educational materials being developed and distributed to prevent future similar occurrences? Comments: ❑ Yes ❑ No ❑NA ❑ Yes ❑ No ❑NA ❑ Yes ❑ No ❑NA ❑ NE ❑ NE ❑ NE Form CS-SSO Page 10 Other (Pictures and police report, as applicable, must be available upon request.) Describe: Were adequate equipment and resources available to fix the problem? If Yes, explain: If the problem could not be immediately repaired, what actions were taken to lessen the impact of the SSO? Comments: El Yes n No nNA El Yes n No nNA MM MM Form CS-SSO Page I I Pipe Failure (Break) Pipe size (inches) What is the pipe material What is the approximate age of the line/ pipe (years old) Is this a gravity line? Is this a force main line? Is the line a "High Priority" line? Last inspection date and findings If a force main then, Was the break on the force main vertical? Was the break on the force main horizontal? Was the leak at the joint due to gasket failure ? Was the leak at the joint due to split bell? ❑ Yes ❑ No ❑NA ❑ NE ❑ Yes ❑ No ❑NA ❑ NE ❑ Yes ❑ No [:]NA ❑ NE ❑ Yes ❑ No [_]NA ❑ NE ❑ Yes ❑ No ❑NA ❑ NE ❑ Yes ❑ No [:]NA ❑ NE ❑ Yes ❑ No [:]NA ❑ NE When was the last inspection or test of the nearest air -release valve to determine if operable? When was the last maintenance of the air release performed? If gravity sewer then, Does the line receive flow from a force main immediately upstream ❑ Yes ❑ No [:]NA ❑ NE of the failed section of pipe? If yes, what measures are taken to control the hydrogen sulfide production? When was the line last inspected or videoed? If line collapsed, what is the condition of the line up and down stream of the failure? What type of repair was made? If temporary, when is the permanent repair planned? Have there been other failures of this line in the past five years? ❑ Yes ❑ No [:]NA ❑ NE If so, then describe Form CS-SSO Page 12 System Visitation ORC ❑ Yes ❑ Yes Name: Kathy Broadwell Certification Number: 1000052 Date visited: 9/27/2024 Time visited: 2:40pm How was the SSO remediated (i./e. Stopped and cleaned up)? Once the issue was reconized, the line was snaked and cleared and flow went back to normal. A contractor was called out the same day to jet the line to insure there would not be anymore issues. After the spill was stopped, the impacted area was treated with lime and straw. As a representative for the responsible party, I certify that the information contained in this report is true and accurate to the best of my knowledge. Person submitting claim: Steven Johnson Date: 10/ 1 /2024 �e Signature: Title: U/ r�f �t �CJ✓ Telephone Number: 919-201-2058 Any additional information desired to be submitted should be sent to the appropriate Division Regional Office within five business days of first knowledge of the SSO with reference to the incident number (the incident number is only generated when electronic entry of this form is completed, if used). Form CS-SSO Page 13