HomeMy WebLinkAboutNC0003573_Inspection_20240912ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Certified Mail # Return Receipt Requested Brian Long The Chemours Company Fc LLC 22828 Hwy 87 W Fayetteville, NC 28306 NORTH CAROLINA Environmental Quality September 12, 2024 SUBJECT: Compliance Inspection Report Chemours Company -Fayetteville Works NPDES WW Permit No. NC0003573 Bladen County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Chemours Company -Fayetteville Works on 8/02/2024. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0003573. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". The permit was issued in 2012 and expired in 2016. Permittee has submitted a renewal application. The current permit is outdated and does not accurately reflect plant's current status. Aeration tank is now being used by stormwater process and will be covered under storm water permit. Aeration basin currently has "pre-digestor" written on side of tank. Digester tank is now being used as aeration tank. Center of Clarifier has a "flooring" 2 ft deep and maintains solids buildup due to design. Plant is using an old screw press and centrifuge run roughly 3-4 days per week to adequately dry solids. Solids are hauled to a hazardous waste site in Alabama. Facility was clean and neat in appearance. All treatment units appeared to be in working order at the time of the inspection. There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. INA North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1 225 Green Street, Suite 714 1 Fayetteville, North Carolina 28301 910.433.3300 If you should have any questions, please do not hesitate to contact Evelyn Hairr with the Water Quality Regional Operations Section in the Fayetteville Regional Office at 910-433-3300 or via email at evelyn.hairr@deq.nc.gov. ATTACHMENTS Ec: NPDES Laserfiche File Sincerely, DocuSigned b(ywM1/.N}'�I,�'- I E4E1A9691 DB248E... 9/25/2024 Mark Brantley, Regional Supervisor Water Quality Regional Operations Section Fayetteville Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1 225 Green Street, Suite 714 1 Fayetteville, North Carolina 28301 910.433.3300 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NC0003573 I11 121 24/08/02 I17 18I � I 19 I s I 201 I 6 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II J Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 71 I 74 79 I I I I I I I80 701 I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:OOAM 24/08/02 12/03/01 Chemours Company -Fayetteville Works 22828 NC Highway 87 West Exit Time/Date Permit Expiration Date Fayetteville NC 283067332 12:OOPM 24/08/02 16/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Jamie Ray Lewis/ORC/910-678-1219/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Brian Long,22828 Hwy 87 W Fayetteville NC 28306H910-678-1415/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Si bl;g4% jj%pector(s) Agency/Office/Phone and Fax Numbers Date Evelyn Hairr &4" ru � - DWR/FRO WQ/704-433-3300/ 9/12/2024 Sharon Mora o %s E1402... DWR/FRO WQ/910-433-3300/ 9/12/2024 sLvbin, AtwaA. viewer Agency/Office/Phone and Fax Numbers Date ManagemPVt qA Rev Signature of cu Igoe o Mark Brantley 9/25/2024 �.a� �a�/Division of Water Quality/910-433-3300 Ext.727/ yF EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NC0003573 I11 12I 24/08/02 117 18 i c i (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The permit was issued in 2012 and expired in 2016. Permittee has submitted a renewal application. The current permit is outdated and does not accurately reflect plant's current status. Aeration tank is now being used by stormwater process and will be covered under storm water permit. Aeration basin currently has "pre-digestor" written on side of tank. Digester tank is now being used as aeration tank. Center of Clarifier has a "flooring" 2 ft deep and maintains solids buildup due to design. Plant is using an old screw press and centrifuge run roughly 3-4 days per week to adequately dry solids. Solids are hauled to a hazardous waste site in Alabama. Facility was clean and neat in appearance. All treatment units appeared to be in working order at the time of the inspection. Page# Permit: NC0003573 Owner -Facility: Chemours Company -Fayetteville Works Inspection Date: 08/02/2024 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ■ ❑ ❑ ❑ application? Is the facility as described in the permit? ❑ ■ ❑ ❑ # Are there any special conditions for the permit? ❑ ■ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The permit was issued in 2012 and expired in 2016. Permittee has submitted an renewal application. The current permit is outdated and does not accurately reflect plant's current status. Aeration tank is now being used by stormwater process and will be covered under storm water permit. Digester tank is now being used as aeration tank. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ■ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ■ ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ■ Name of individual performing the sampling ■ Results of analysis and calibration ■ Dates of analysis ■ Name of person performing analyses ■ Transported COCs ■ Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ■ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ■ ❑ ❑ ❑ operator on each shift? Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ■ ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility ■ ❑ ❑ ❑ classification? Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ■ ❑ Comment: TBL contract lab is used for permit sampling and to calibrate flow meters Page# 3 Permit: NC0003573 Inspection Date: 08/02/2024 Upstream / Downstream Sampling Owner -Facility: Chemours Company -Fayetteville Works Inspection Type: Compliance Evaluation Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Comment: User is a member of the cape fear river basin association Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Comment: Yes No NA NE ■ ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Influent Sampling Yes No NA NE # Is composite sampling flow proportional? ❑ 0 ❑ ❑ Is sample collected above side streams? ■ ❑ ❑ ❑ Is proper volume collected? ■ ❑ ❑ ❑ Is the tubing clean? ❑ 0 ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ ■ ❑ degrees Celsius)? Is sampling performed according to the permit? ❑ ❑ 0 ❑ Comment: Influent samplinq is not reported and for plant use only. Samplinq is time based. head tubing had some film, all tubing is usually replaced monthly. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑ Is the wet well free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Page# 4 Permit: NC0003573 Inspection Date: 08/02/2024 Owner -Facility: Chemours Company -Fayetteville Works Inspection Type: Compliance Evaluation Pump Station - Influent Yes No NA NE Are all pumps operable? 0 ❑ ❑ ❑ Are float controls operable? ❑ ❑ ❑ Is SCADA telemetry available and operational? 0 ❑ ❑ ❑ Is audible and visual alarm available and operational? S ❑ ❑ ❑ Comment: Equalization Basins Yes No NA NE Is the basin aerated? 0 ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? ❑ 0 ❑ ❑ Are float controls operable? 0 ❑ ❑ ❑ Are audible and visual alarms operable? 0 ❑ ❑ ❑ # Is basin size/volume adequate? ■ ❑ ❑ ❑ Comment: A work order is in for repairs on an aerator, a second aerator has also been removed from basin for repairs Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Comment: Center of Clarifier has a "flooring" 2 ft deep and maintains solids buildup due to design Aeration Basins Mode of operation Yes No NA NE Ext. Air Page# 5 Permit: NC0003573 Inspection Date: 08/02/2024 Aeration Basins Owner -Facility: Chemours Company -Fayetteville Works Inspection Type: Compliance Evaluation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/1) Comment: Aeration basin currently has "pre-digestor" written on side of tank Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Solids Handling Equipment Is the equipment operational? Is the chemical feed equipment operational? Is storage adequate? Is the site free of high level of solids in filtrate from filter presses or vacuum filters? Is the site free of sludge buildup on belts and/or rollers of filter press? Is the site free of excessive moisture in belt filter press sludge cake? The facility has an approved sludge management plan? Yes No NA NE Diffused ❑ ■ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ■ Comment: Plant is using an old screw press and centrifuge run roughly 3-4 days per week to adequately dry solids. Solids are hauled to a hazardous waste site in Alabama Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? ❑ 0 ❑ ❑ Page# 6 Permit: NC0003573 Inspection Date: 08/02/2024 Flow Measurement - Influent Is flow meter calibrated annually? Owner -Facility: Chemours Company -Fayetteville Works Inspection Type: Compliance Evaluation Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ Page# 7 Regional Inspectors' Checklist for Field Parameters [This checklist is to be completed during regional plant inspections for Field Laboratories denoted by certification numbers in the 5000s.] Facility Name: Chemours Company Fayetteville Works Regional Plant Inspector: Sharon Moran Permit #: NC0003573 Regional Inspector Contact #: 910 916 3489 Field Lab Certification #: 5105 Region: FRO Lab Contact: Jamie Lewis Date: 8/02/2024 I. Check the parameter(s) performed at this site for reporting purposes. Total Residual Chlorine (TRC) jPTTemperature (TEMP) El Specific Conductance (SC) ❑ Dissolved Oxygen (DO) ❑ Settleable Residue (SETT) II. General Laboratory note any exceptions in section XI Are instruments, meters, probes, photometric cells, etc. maintained in good condition? ZFYes ❑ No Are standards, reagents and consumables used within manufacturer expiration dates? [TRC gel standard is exempt.] 0 Yes ❑ No Are the following items documented (� where applicable): Item TRC TEMP DO SC SETT Date of sample collection* Time of sample collection* Sample collector's initials or signature Date of sample analysis* rf Time of sample analysis* l/ Analyst initials or signature fz Sample site i.e., facility name, location, ID, etc. Instrument ID Parameter Data qualifiers, when required yJ *Date and time of sample collection and analysis may be the same for in sitl or on -site meAsurements. III. Total Residual Chlorine — reference method: Wk Total Residual Chlorine meter make and model: Is a check standard analyzed each day of use? (Circle one: gel or liquid standard) ❑ Yes ❑ No Does the check standard recover within ±10% of the known value? ❑ Yes ❑ No What is the assigned/observed value of the daily check standard? Is a 5-standard calibration verificationperformed? Note date of last verification: ❑ Yes ❑ No Alternatively, does the lab construct a linear regression, using 5 standards, to calculate results? Note date of last calibration curve constructed: ❑ Yes ❑ No True values: ❑ pg/L ❑ mg/L Obtained values: ❑ pg/L ❑ mg/L What program are samples analyzed on? Are results reported in proper units? Check one: ❑ /L ❑ m /L ❑ Yes ❑ No Are results reported between the facility's permit limit and the compliance limit of 50 p /L? ❑ Yes ❑ No Are results less than the low standard reported as "<x", where x=low standard conc.? ❑ Yes ❑ No Is DPD/buffer added within 15 minutes of collection? ❑ Yes ❑ No Is a post -analysis check standard analyzed if samples are analyzed at multiple sites? ❑ Yes ❑ No IV. pH — reference method: pH meter manufacturer and model: Hach HQ44Od Is the pH meter calibrated with at least 2 buffers per mfg's instructions each day of use? Note buffers used: 4, 7, 10 Yes ❑ No Is the pH meter calibration checked with an additional buffer prior to sample analysis? Note check buffer used: 7 Ij es ❑ No Does the check buffer read within ±0.1 S.U. of the known value? Yes ❑ No Are the following items documented: Meter calibration? El Yes ❑ No Check buffer reading(s)? ['Yes ❑ No Are samples analyzed within 15 minutes of collection? DYes ❑ No 9 Are sample results reported to 0.1 pH units on the eDMR? Yes ❑ No Is a post -analysis check buffer analyzed if samples are analyzed at multi le sites? ❑ Yes ❑ No V. Tern erature — reference method: mperature? Check a;What apply: El pH meter What instrument(s) is used to measuWagital El DO meter El Conductivity meter thermometeit,� Glass thermometer Is the instrument/thermometer calibration checked at least annually against a NIST traceable thermometer? yes El No Is NIST traceability documentation maintained on site? El Yes ❑ No Are samples measured within 15 minutes? es ❑ No Are sample results reported in degrees C? ETYes ❑ No VI. Dissolved Oxygen — reference method: DO meter make and model: Is the air calibration of the DO meter performed each day of use? ❑ Yes ❑ No Is meter calibration documented? ❑ Yes ❑ No Are samples analyzed within 15 minutes of collection? ❑ Yes ❑ No Are results reported in m /L? ❑ Yes ❑ No If samples are analyzed at multiple sites, is the meter recalibrated at each site or a post- analysis calibration verification performed? ❑ Yes ❑ No Does the post -analysis verification theoretical value agree within 0.5 mg/L of the meter calibration reading? ❑ Yes ❑ No VII. Conductivity — reference method: Conductivity meter make and model: Is the meter calibrated daily according to the manufacturer's instructions? Note standard used this is generally a one -point calibration): ❑ Yes ❑ No Is a daily check standard analyzed? Note value: ❑ Yes ❑ No Is meter calibration documented? ❑ Yes ❑ No Are samples analyzed within 28 days of collection? ❑ Yes ❑ No Is a post -analysis check standard analyzed if multiple samples are analyzed? Are results reported in pmhos/cm (some meters display equivalent S/cm units)? ❑ Yes ❑ No Vill. Settleable Residue — reference method: Does the laboratory have an Imhoff Cone in good condition? ❑ Yes ❑ No Is the sample settled for 1 hour? ❑ Yes ❑ No Is the sample agitated after 45 minutes? ❑ Yes ❑ No Are the following items documented: Volume of sample analyzed? Note volume analyzed (must use 1 L): ❑ Yes ❑ No Date and time of sample analysis(settling start time)? ❑ Yes ❑ No Time of agitation after 45 minutes of settling? ❑ Yes ❑ No Sample analysis completion(settling end time)? ❑ Yes ❑ No Are samples analyzed within 48 hours of collection? ❑ Yes ❑ No Are results reported in ml/L? ❑ Yes ❑ No IX. Was a paper trail (comparing contract lab and on -site data to DMRs) performed? If so, list months reviewed: March 2024 ❑ Yes ❑ No X. Is follow-up by the Laboratory Certification program recommended? ❑ Yes ❑ No XI. Additional comments: Please submit a copy of this completed form to the Laboratory Certification program at: DWR Lab Certification, Water Sciences Section, 1623 Mail Service Center, Raleigh NC, 27699-1623 Electronic copies may be emailed to Jennifer.seaver(a)ncdenr.gov. Revision 3/2021