Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0045676_Application (FTSE)_20240830
State of North Carolina Department of Environmental Quality DWR Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 10-23&SUPPORTING DOCUMENTATION Application Number: Wt?00%T10 7(04o be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: Town of Clayton(company,municipality. HOA, utility,etc.) 2. Applicant type: ❑ Individual ❑Corporation ❑General Partnership ❑ Privately-Owned Public Utility ❑ Federal ❑State/County ®Municipal ❑Other 3. Signature authority's name: Joshua Baird, PE.CFM per 15A NCAC 02T.0106(b) Title: Engineering Director, Interim Water Resources Director -- - - NC Dept ofEnviroctmentai Quality4. Applicant's mailing address: PO Sox 879 City: Clayton Stnte:NC Zip: 27528- 5. Applicant's contact information: JU 1. 2 D 2024 Phone number:(919) 555 -1554 Email Address:ibaird a townofciaytounc.orx R8l00R4on1OMW 11. PROJECT INFORMATION: I. Project name: Country Lane Subdivision 2. Application/Project status: ® Proposed(New Permit) ❑ Existing Permit/Project If a modification,provide the existing permit number: WQ00 and issued date: , For modifications,also attach a detailed narrative description as described in Item G of the checklist. If new construction,but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Johnston 4. Approximate Coordinates(Decimal Degrees): Latitude: 35.623 Longitude: -78.474 5. Parcel ID(if applicable): 165804821701 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: I. Professional Engineer:Jayson 13uftkin, PE License Number:051054 Firm: WithersRavenei, Inc. Mailing address: 115 MacKenan Drive City: Cary State: NC Zip: 2751 l- Phone number:(919)238-0343 Email Address: ibtiffkui a,,witliersravcncl.coni IV. WASTEWATER TREATMENT FACILITY(WWTF)INFORMATION: I. Facility Name: Little Creek Water Reclamation Facility Permit Number: NCO025453 Owner Name: Town of Clayton V. RECEIVING DOWNSTREAM SEWER INFORMATION: I. Permit Number(s): WQ P4me Sk�aN A- QN� Setttan ?01\A l 5W1111 2. Downstream(Receiving)Sewer Information: 8 inch 0 Gravity 0 Force Main 3, System Wide Collection System Permit Nuniber(s)(if applicable): WQCS 00//0 Owner Name(s):Town of Clayton FORM: FTA 10-23 Page 1 of 5 N I. GENERAL REQUIREMENTS I. If the Applicant is a Privately-Owned Public Utility,has a Certificate of Public Convenience and Necessity been attached'? ❑Yes ❑ No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement(FORM: DEV)been attached? ❑Yes ❑ No ®N/A 3. If the Applicant is a Home/Propetty Owners'Association,has an IIOXPOA Operational Agreement(FORM: HOA)and supplementary documentation as required by 15A NCAC 02T.01 15(c)been attached'? ❑ Yes ❑ No ® N/A 4. Origin of wastewater.(check all that apply): ® Residential(Individually Owned) ❑Retail (stores,centers,malls) ❑Car Wash ❑ Residential(Leased) ❑Retail with food preparation/servicc ❑ Hotel and/or Motels ❑ School /preschool/day care ❑Medical/dental/veterinary facilities ®Swimming Pool/Clubhouse ❑ Food and drink facilities ❑Church ❑Swimming Poo]iFilter Backwash El Businesses/offices/ factories ❑ Nursing Home ❑Other(Explain in Attachment) 5. Nature of wastewater: 100%Domestic %Commercial %Industrial(See I SA NCAC 02T.0103(20)) If Industrial, is there a Pretreatment Program in effect?❑ Yes El No 6. Has a flow reduction been approved under 15A NCAC 02T.01 14(f)'? ® Yes ❑ No Y If des,provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type(see 02T.0114(t)) Daily Design Flow'" No.of Units Flow Single Family Detached Residential Homes 250 gal/day 130 32,500 GPD Amenity Center gal/ 2,OOOGPD gal/ GPD gal/ GPD gall GPD gal/ GPD Total 34,500 GPD a See 15A NCAC 02T .0114(b). (d),(e)(I)and (e)(2) for caveats to wastewater design flow rates(i.e. proposed unknown non-residential development uses. public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in C.S.42A-4). b Per I SA NCAC 02T .0114(c),design flow rates for establishments not identified(in table 15A NCAC 02T.01 14)shall be determined using available flow data,water using fixtures,occupancy or operation patterns,and other measured data. 8. Wastewater generated by project. 34.500 GPD(per 15A NCAC 02T A 114 and G.S. 14 3-21.5.1_) Do not include future flows or previously permitted allocations If permitted flow is zero,please indicate why: ❑Pump Station'.,Force Main or Gravity Sewer where flow wi'l be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑Other(Explain): FORM: FTA 10-23 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA(If Applicable)-02T A305& MDC_(Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size(inches) Length(feet) Material 8" 6.023 SDR 35 PVC 8" 5.029 C900 PVC 8" 473 DIP Section It & III of the M DC for Permitting of Gravity Sewers contains information related to design criteria i Section Ill contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA(If Applicable)—_02T.0305& IVIDC(Punig Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT l. Pump station number or name: 2. Approximate Coordinates(Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design (low of the pump station: millions gallons per day(firm capacity) This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s)per pump(s): gallons per minute(GPM)at feet total dynamic head(TDH) 5. Summarize the force main to be permitted(for this Pump Station): Size(inches) Length(feet) Material If any portion of the force main is less than 4-inches in diameter,please identify the method of solids reduction per MDCPSFM Section 2.01 C.I.b. ❑Grinder Pump ❑ Mechanical Bar Screen ❑Other(please specify) 6. Power reliability in accordance with ISA NCAC 021 .030500(I): ❑ Standby power source or ❑ Standby pump Must have automatic activation and telemetry- I SA NCAC 02T.0305(h)(1)(B): Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day r Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation,quick-connection receptacle and telemetry- or ❑ Portable pumping;nit with plugged emergency pump comiection and telemetry: Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. If the portable power Source or pump is dedicated to multiple pump stations,an evaluation of all the pump stations'storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes,shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 10 23 Page 3 of 5 IX. SETBACKS &SEPARATIONS—(02B.0200& I5A NCAC 02T.0305(f)): I. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(t) &(&V ® Yes ❑ No iSA NCAC 02T.0305 t contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below(vertical) 18 inches =Water mains(vertical -water over sewer preferred, including in benched trenches) 18 inches 'Water mains(horizontal) 10 feet Reclaimed water lines(vertical-reclaimed over sewer) 18 inches Reclaimed water lines(horizontal-reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells.WS-I waters of Class I or Class 11 impounded reservoirs used as a source of drinking water,and associated wetlands. 100 feet **Waters classified WS(except WS-I or WS-V), B,SA,ORW, WQW,or SB from normal high water(or tide elevation)and wetlands associated with these waters(see item IX.2) 50 feet **Any other stream, lake, Impoundment,or ground water lowering and surface drainage ditches,as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation(horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade(vertical) 36 inches If noncompliance with 02T.0305(1)or(g),see Section X.I of this application *I5A NCAC 02T.0305(r;)contains alternatives where separations in 02T.0305(l)cannot be achieved. Please check"yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications wcboae,c 2. Does this project comply with the minimum separation requirements for water mains? ®Yes ❑No ❑ N/A If no,please refer to 15A NCAC I9C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE,verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ®Yes ❑No ❑N/A Please provide supplementary information identifying the areas of non-conformance. %- See the Division's draft separation resluir;emenls for situations where separation cannot be met. No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules'? ®Yes Basin name: Neuse ❑No If ycs,does the project comply with setbacks found in the river basin rules per 15A NCAC 0213.0200? ® Yes ❑ No This includes Trout Buffered Streams per 15A NCAC 213.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications'? i Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6)(additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6},directly related environmental permits or certification applications must be being prepared, have been applied for,or have been obtained. Issuance of this pennit is contingent on issuance of dependent permits(erosion and sedimentation control plans,storinwater management plans,etc.). 7. Does this project include any sewer collection lines that are deemed"high-priority?" ❑ Yes ® No Per 15A NCAC 02T.0402."high-priority sewer"means any aerial sewer,sewer contacting surface waters, siphon,or sewers positioned parallel to streambanks that are subject to erosion that undennines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. If yes, include an attachment with details for each line,including type(aerial line,size,material,and location). High priority lines shall be inspected by the permittee or its representative at least once every six-months and inspections documented per 15A NCAC 02T.0403(a)(5)or the permittee's individual System-Wide Collection permit. FORM: FTA 10-23 Page 4 of 5 K. CERTIFICATIONS: 1, Does the submitted system comply with 15A NCAC 02T, the Minimtun Design Criteria for the Permitting of Putrp Stalwns and Force Mains(latest version), and the Gravity Sewer Minimum_Design Criteria(latest version)as applicable? ® Yes ❑No If no, for projects requiring a single variance, complete and submit the Variance/Altemative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the renuest will be issued concurrently with the approval of the permit, and protects requiring a variance approval may,be suhfect to longer review times. For projects requiring tivo or more variances or where the variance is determined by the Division to be a significant portion of the project,the full technical review is required. 2. Professional Engineer's Certification: 1, Jayson Buftkin attest that this application for Country Lane Subdivision (Professional Engineer's name from Application Item tit.).) (Project Name from Application stein 11.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,engineering calculations,and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers(latest version),and the Minimum Design Criteria for the Fast-Track Permitting Of Pump Stations and Force Mains(latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor. which may include a fine not to exceed$10.000,as well as civil penalties up to$25.000 per violation. Misrepresentation of the application information,including failure to disclose any design nun-compliance with the applicable Rules and design criteria,may subject the North Carolina-licensed Professional Engineer to referral to the licensing board.(21 NCAC 56.0701) ......... ... .. .. °°ocodtiotlpp0000 North Carolina Professional Engineer's seal,signature,and date: o°°°�N E A R pe0°o, 00 2 °oeCCeeoocc��°ooe /,/00 e a°O�(GSJ��°00 o"i' Go o e� � e- o o° SI=AL e o e 051054 0 0 o e e a° e' �o `s gOOp°ooeo°Oo! 6/18124 3. Applicants Certification per 15A NCAC 02T.0I06(b): 1 Joshua Baird, PE, CFM ,attest that this application for Country Lane Subdivision (Signature Authority Nano from Application licm 1.3.) (Project Namc t'rom Application licm 11.11 attest that this application has been reviewed by pre and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. l understand that any discharge of wastewater from this non-discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,injunctive relief,and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package arc not completed and that if all required supporting information and attachments arc not included, [his application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as civil penalties up to$25.000 per violation. 711 zo,(' Signature: Date: r�I 1 FORM: FTA 10-23 Page 5 of 5 O W i t h e r s R a v e n e l NC Dept of Environmental Quality r Our People.Your Success. L 29 2024 July 26,2024 Raleigh Repong woe NCDEQ-DWR Attn: Public Water Supply Section 1634 Mail Service Center Raleigh, NC 27699-1634 RE:Chatham Park- Country Lane Subdivision Sewer System Extension Permit Dear NCDEQ Reviewer, On behalf of Meritage Homes of the Carolinas,Inc.,please find the attached documentation in support of a Fast Track Application(FTA 10-23)for the referenced project. As noted in the application,this project will consist of LF 11,052 of 8" PVC sewer lines and 473 LF of 8" DIP Sewer Lines located at the intersection of Jasper Drive and Country Lane Southeast of Barber Mill Road and will connect to pump station and gravity sewer for Country Lane Subdivision which will be permitted and constructed under separate cover. The Sewer proposed within this application will be tributary to the Little Creek (Sam's Branch) Water Reclamation Facility(NC0025453) and will serve Country Lane Subdivision consisting of 130 single family detached homes and an Amenity Center within this development. The proposed project will meet all the DWR's minimum design criteria for sanitary sewer extensions.The design flow rate for this project is calculated at 34,500 gpd based on NCAC 2T Rules for wastewater flow rates and the DEQ approved sewer flow reduction of 250 gal/day, approved under separate cover for Chatham Park,is included with this submittal package. The proposed sanitary sewer line sizes are more than adequate to convey the design flow rates. Please find attached the following information in support of the application: • Fast Track Sewer System Extension Application(FTA 10-23) • Flow Tracking/Acceptance Form for Sewer Extension Applications(FTSE 10-23) • Street Level Map • USGS Aerial Topo Map • Country Lane Subdivision Sewer Allocation Memo If you have any questions regarding this request or if you require any additional information,please feel free to contact me at 919.238.0343 or ibuffkin@withersravenel.com. Sincerely Wi hersRavenel J/yvson P. Buffkin, PE Project Manager 115 MacKenan Drive I Cary, NC 27511 t:919.469.3340 1 f: 919.467.6008 1 www.withersravenel.com I License No.C-0832 Cary I Greensboro I Pittsboro I Raleigh I Wilmington 40 WithersRavenel 00 Our People.Your Success. August 30, 2024 NCDEQ-DWR Wastewater Management 3600 Barrett Drive Raleigh, NC 27609 RE: Country Lane Subdivision V Sewer Review NCDEQ-DWR Project No.TBD WR Project No.02200402.00 Dear Tanvir, We are writing this letter in response to comments dated August 28, 2024. Each of the comments are repeated below,followed by our response. NCDEQ-DWR General 1. Is this an ARPA funded project? If so, please include the DWI assigned ARPA project number in your response. RESPONSE:This is not on ARPA funded project.As such,a DWI assigned ARPA project number will not be needed. Application 2. Your application is missing following items: a. Signed FTSE RESPONSE:Signed FTSE has been included in this resubmittal package. b. USGS and Aerial Map with sufficient information and in proper scale. 1) According to Section F of the Application Instructions, an 8.5-inch x 11-inch color copy of a USGS Topographic Map and an aerial map should be included with the application. The maps need to clearly identify the project area, including the closest surface waters,general location of the gravity sewer, pumpstations,and force mains, and the downstream connection points for the receiving sewer. Please provide the required maps according to the application requirements. RESPONSE:USGS and Aerial Topo Maps have been included in this resubmittal package. 3. As I was unable to seethe proposed sewer lines on the maps, please verify that the requested 11,525 linear feet gravity sewer does not cross any streams or deemed high priority as mentioned in section IX.7. RESPONSE: We have provided the Overall Utility Plan show casing the proposed sewer layout as denoted in GREEN. Sincerely, 7'thersRavenel Jayson Buffkin, PE Project Manager 115 MacKenan Drive I Cary, NC 27511 t: 919.469.3340 1 f: 919.467.6008 1 www.withersravenel.com License No. F-1479 Asheville I Cary I Greensboro I Pittsboro I Raleigh I Southern Pines I Wilmington %0 WithersRavenel Letter of Transmittal SS Grant Drive, Suite D Pittsboro, NC 27312 t: 919.469.3340 J f: 919.467,6008 • • zric 6/2024 ••• • 200402 • Water Supply Section TO: NCDEQ-DWR Attn:Public Water Supply Section 1634 Mail Service Center Country Lane Subdivision-DEQ Sewer Submittal Raleigh,NC 27699 WE ARE SENDING YOU THE FOLLOWING ITEMF ® Attached O Under Separate Cover Via O Shop Drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications O Copy of Letter O Change Order O Disk ® Other I DESCRIPTION • • 1 Cover Letter 1 FTA NC Dept ofEnvimnmj= 1 FTSE Ly 1 USGS 1 Street Level Map 1 Application Fee in the amt.$600.00 to NCDEQ RcgkxW 01NM 2 Thumb Drives with PDF Submittal Items THESE ARE TRANSMITTED as checked below. ® For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution ❑ As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ Other ❑ For bids due ❑ Prints returned after loan to us REMARKS: Liz Owens Jayson P.Buffkin,PE COPY TO lowens@withersravenel.com SIGNED. jbuffkin@withersravenel.com QA/QC RECEIVED. If enclosures are not as noted,kindly notify us at once. State of North Carolina Department of Environmental Quality DWR Division of Water Resources Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-23) Entity Requesting Allocation: Town of Clayton Project Name for which flow is being requested: Country Lane More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Little Creek (Sam's Branch) Water Reclamation Facility b. WWTP Facility Permit#: NCO025453 All flows are in MGD c. WWTP facility's permitted flow 5.65 (LCWRF 2.5 + JoCo 1.4+Raleigh 1.75) d. Estimated obligated flow not yet tributary to the WWTP 0.9105 e. WWTP facility's actual avg. flow 3.338 f. Total flow for this specific request 0,0345 g. Total actual and obligated flows to the facility 4.283 h. Percent of permitted flow used 75.8% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm/p fl, Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow,MGD MGD Flow Capacity*** *The Firm Capacity(design flow)of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor(pf)not less than 2.5,per Section 2.02(A)(4)(c)of the Minimum Design Criteria. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is<0. Downstream Facility Name (Sewer): UNK Page 1 of 7 FTSE 10-23 Downstream Pen-nit Number: UNK III. Certification Statement: I Joshua Baird certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. t / 12o7 S' -ning Official Signature Date Tit e of S' ing Official Page 2 of 7 FTSE 10-23 Country Lane Aerial Map AW Ire— ,' ^•+i ��` .., � .fir �� �. a s D +!maJy r 6 Ilk {d a� Country Lane USGS Map .l. .L- . 1 J. Q- .4 J. J. .I. J. .L- 6. SroNEHEN(' .4 .4 F,QJ r,. .4 .L- .L. .L. r r. 4. IJ- r, L J. J. J. .I. ZZ i r r .L tiG \ oG Qf m O a, r. .L. L Z. ANGUS r r r. AMELIA CHURCH RD .' 4" )RD CT _ � Clayto 4 i wo 4SpFR r. r. Oq � 1 Q: HUNTER ESTS r r. .4 z PON_D_fROSA_D"' .4 320 Q GREEN LN \P s� v = _ r. . V iil' 310 D F fla-o^al 6,'a Piacio^al Ec--c Data;et.3DEP Elevef _ _ e .. � � o^°,co,am Geogrephic`.am=s rrc•rafonSys-em,Nations -_ z_�_ -�� - _ _- __ _ •_ _ _ —.ign Envelope ID:726C6184-D33E-4180-968CAC2A]CBDA616 I c I I 09 / — —�/ \ / N A I PHASE IB ( I / .::UBLIC U:LITY�.::r: \.:;-, � / \ \�\ \ \ > N\ rtrtll / \ "WPUBLICUTILITVPND / / 3 I I _ I \�� © I — / / ® /\�\ GREENWAY ASEMEM G / \ i / - /�/ / II 12 —� \ ® \ FHA AHA ETA _\ US RI �V1/ I \`\/ \ \ \ \ l l \ ,�^ c ( \ I / \\ V 1 c 6"PVC C-9DD 51"DBH IlE oax BEND RIPARIANBUFFER: u I/ I 'WATERLINE 8'%8'iE�\\`\ _ y �iREE TO BE PRESERVE@D \ \ — ® (316"OV @L\11AN08 I Un p) 50'NEUSE RI ER 6-PVC O800 / " OPEN SPACE WET POND I tO4 ® `� WATaE@RLINE \ \ Ir\�`RIPPRI4N BUFFER \ \ POCKET KEPARK \ITE THIN 61PVC F900\ a�FF` -OA W TER LwE \J / /// / \ FHA FHA 8"CAP wl TEMPORARY / I 46°BEND \\ ` 16 � �� //� - I 11.2E° 2 BOV FOR PHASING / E PVC G9pp 19 / / /BEND 6'PVC G9pp _ I �. O WETLAND6 � / / WATERLINE \ J 1125° WATER LINE \ WETLANDS \ \ / / REMO/EEX BOA RYP) fi'180LATION VALVE \ I `` ANDCONNECTTO " / .BEND (TYP) PHASE IB ` E%.WATER MAIN FHA O _BEND__ ��m ® \ , F q O'PVC C�00 'fl i 8—TEE \ BEND WATER LINE I I I 1,16'GV 11.25• \ 8'ISOLATION VALVE \ 5° I (1)8'X6'CROSS BEND WATERLINE 0'%0'TEE / \ XL� / BE �i O'PVC o900 (2J B'GV (318"GV \ / I FHA FHA / WATERLINE �1 eFHA--- --. \ _ FHA (1)8"X fi•RED V I X XTTEE (t'8 �T •%6BRE0- -- WATERLINE B(3)r GV ��a QD PHASEIA •� B:CAPW9TEMPoRARVNE ��nEOD 02 BOV FOR PHASING/3g I I - J[O)IPED _ - - -- _ - i \ Z 1 \� BUFFER RIPARIAN BUFFER_�\" / w WATERLINE rEN,o800 ---- PHASE2 - �� \ / ::..::y`�.:: I • J 1_1_L_L_I_J—�—L_L_I—J— _ Q PHASE IA B'PVC L gooINE /----OpENBPACEI':""""" `7+ [1 O -T--- - ��_ �.._::30'PUBLIC UTILITVPND P CG WATERLINE r T r 6"PVC C500 1 POCIT PARK 6 WATERLINE (1)8'XBCROSSi'180'TEE pHASE to PROPOSm 6' WIPICNIC :GREENWAY EASEMEM 2 S GV / FORCEMAIIN p�„Y S"ISOATIONVPLVEMGV ' (2023-100CD( SHELTEl ®G -� WATERLINE WATERLINE / 21"DBH WHITE OAK-I50'NEUSE RIVER \ FHA _ - - _ j / \ TREETO BE PRESERVED \\ I OD N RIPARIAN BUFFER WETLANDS F- ()8" FOR PHA PHASE IA I STREETA 2'BOV PHASING /� � F WATEftC � I / 7 O / \ WATERLINE IPueLTA X6"RED T EE\ I Z 3 1 _ \\\ 1 Pee O 8"CAP TEMPORARY / Z _ s•pvc c9po r- I N 8'PVC 0900 46"BEND I EXISTING �I / \\ EX.fi'PVC - PHASE IB - - n L `�F O } WATERLINE I� I\ / \ WATERLINE Irk FUTUREAMENITY SITE(1.8 AR) I _ /` (16 J FUTUREAMENITV TOINCLUDEONEOF ® FHA N CR��_\�\�� / 6'CAP WI TEMPORARY / CUT-IN TEE I ALVE \ , ` J/ / c6"%6(2)fi ----_2"BOY FOR PHASING \ / �` .-. I^_ ApW \ , 1 THEFOLLOWING:CLUBHOUSE AO 6.WATT LINE 6'ISOLATIONV _ .... Q PLAYGROUND,OR CLUBHOUSE WATERLINE FHA FHA FHA \ -- - / / TEMPORARY WILIFIT MRENTPIPEK I W W FHA -��/ OV FOR PHASING'- /� 30'PUBLIC UTILIIVAND ,'� 1 / K ETF BUFFER 2 W'STREAM� / / 8� � � e'Pac cspp \ I u 6"PVC C-900 6'Xfi'TEE //, 71F // �(�' WATERLINE 20GREENWAV WATERLINE (118'GV �� / PHASES I \ E45EMENT (2)fi'GV � PHASE IA \\\ N / MASTER METER LOCATION TO �- \ // / 5tl STREAMPROPOSEDfi" / BUFFER 6'P CG800 \\ ORCEMAIN CHANGE FROM COUNTY WATER 7j \I I �/ry / I FHA WATERLINE / �" \T / WET POND (2p231pptA) \ SYSTEM TO TOWN WATER SYSTEM y `( J� / ------- -1---- --- -y 22.5°BEND ) / \ Z \ ' V / = / FHA STREETH / / � stl ER mueuo RIPARIANRIAN BUFFER \ J X / EE PONDEROSA DRIVE (2)B'GV - III'TEE 8-CAPWITEMPORARY)fi GV '�e I WATER LINE (31 fi"GV 2"BOY FOR PHASN 8'P G c\ \ VC LIgooNE 6CAPWITEM PHASING ( /j TATIONLOCAPUMP — WATERLINE- 2'BOV FOR PHA6ING / 46 _ I / \ / \ (BV OTHER PLAN) LATIO f 6'ISON VALVE fi'PVC o9p0 I -III 7 I WATERLINE scm A WET POND PHASE IA � - ... ... FHA / PHASES _. _.:.::.:'.:.z':-:. :E: : :.' W 6�C � 6'ISOLATION VALVE "l __ - _ \ I II w O WATER LINE � ....: :... I1225° I ]ob N. — L WATERLINE022002/1/2S I I -Hq I \ yq7 l 1 //�•Y a`) i Date Drawn By / � � / '� 2/1/22 WR _ / Checked By Des goer WR WR \ ® BUFFS(1)6-GV� \ BEBENDS / / (j 8GV EAM / e e / \ O)8'Xfi'REO_- / BUFFER // / Oa=Q,•pFESS/�°y09:0 -r — — SEAL 1054 G 8\ •F't' INE�P 24 WATERLINE a KEY MAP „ I — e FHA \ I 1 TOW 2A6/23 COMMENTS C#2 �3 /// \ I / 2 TOWN OF CLAYTON 8/14/23 TOWN OF CLAYTON OMMENTS 1 — I Town of Clayton 3 COMMENTS 11/6/23 Approved for Construction / CY.1 O^•I I I \ /FHA 4 SITE PLAIN REVISIONS 3/19/24 // \ \ ROA Signature: Date: 5 TOWN OF 6n/za 6 TOWN OF CISYTON x/vn4 a I I COMMENTS 8 as NOTE: Signature: PG-e va Date: PALL TOWN OF CL LRV WTON UTICONSTRULTION SHALL BE Town of Clayton Engineering must be contacted at a E I I PERFORMED IN ACCORDANCE WITH TOWN OF CLAYTON minimum 4f3 hours riot t0 the commencement Of STANDARDSPECIFICATIONSAND DETAILS IN EFFECTATTIME GRAPHIC SCALE p Sheet No. OF UTILITY PERMITTING. construction activities.The Town of Clayton will not be a responsible for errors and/or omissions on these A•O g 2.ALL FHA WATER LINES BETWEEN GATE VALVE AND l'{ s HYLIRANT BHALL Be Dlp 1 Inch=1 so FL. approved set of plans. 9/12/24, 1:35 PM Mail-Pasha,Tanvir-Outlook [External] FW: Country Lane Subdivision-Additional Information Request Morris, Sue <smorris@withersravenel.com> Fri 8/30/2024 3:12 PM To:Pasha,Tanvir <tanvir.pasha@deq.nc.gov> Cc:Buffkin,Jayson <jbuffkin@withersravenel.com>;Walters,Tristan <twalters@withersravenel.com> D 5 attachments (4 MB) Country Lane 1st Sewer Review Comment Response Letter.pdf;Country Lane FTSE-signed.pdf;Country Lane Aerial Map.pdf; Country Lane USGS Map w-Sewer.pdf;Country Lane Overall Utility Plan w-Sewer.pdf; CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Good Afternoon, Tanvir! I don't know if you remember me, but you and I were on a Teams call with Susan Wilson not too long ago...I hope you are doing well! I am writing in response to your comments, below. I have attached a Comment Response Letter and all supporting documentation as our resubmittal for this project. Please let me know if these items satisfy your comments and you are able to issue the permit. If there is anything else you need, please let me know! Thank you...enjoy your holiday weekend! %0 Sue Morris NOSENIOR PROJECT COORDINATOR () 17, F1 © 0 t:919.469.3340 d:919.417.7889 Cary.Nc WITH ERSRAVEN EL.COM From: Pasha,Tanvir<tanvir.pasha2deq.nc.gov> Sent: Wednesday,August 28, 2024 2:10:59 PM To:Joshua Baird <jbaird(@townofclaytonnc.org> Cc: Buf kin,Jayson <jbuf kin(@withersravenel.com> Subject: [EXTERNAL] Country Lane Subdivision—Additional Information Request CAUTION: This email originated from outside of WithersRavenel. Do not click links or open attachments unless you recognize the sender and know the content is safe. Hello Joshua and Jayson, After reviewing the Fast Track Sewer System Extension Application for Country Lane Subdivision, additional information is required in order to further process the application. Please provide the following information by 09 27 24, and note that the requested information must be submitted within 30 days of this request, or the applicant will be required to submit a new application and application fee in accordance with 15A NCAC 02T .0107. https://outlook.office.com/mail/id/AAQkAGQ3ZGU4M2U4LTY2ZTUtNDhiMC04MGlyLTg2ZjEl NGVIMjk4MwAQAM9h238rRQ5Hp5okni1 UCCs%3D?nat... 1/3 9/12/24, 1:35 PM Mail-Pasha,Tanvir-Outlook 1. Is this an ARPA funded project? If so,_please include the DWI assigned ARPA project number in your response. 2. Your application is missing following items: a. Signed USE b. USGS and Aerial Map with sufficient information and in proper scale. i. According to Section F of the Application Instructions, an 8.5-inch x 11-inch color copy of a USGS Topographic Map and an aerial map should be included with the application. The maps need to clearly identify the project area, including the closest surface waters, general location of the gravity sewer, pumpstations, and force mains, and the downstream connection points for the receiving sewer. Please provide the required maps according to the application requirements. 3. As I was unable to see the proposed sewer lines on the maps, please verify that the requested 11,525 linear feet gravity sewer does not cross any streams or deemed high priority as mentioned in section IX.7. 15A NCAC 02T .0107 Staff Review and Permit Preparation states: • "(2) (e) If an application is accepted and later found to be incomplete, the applicant shall be advised how the application or accompanying supporting information may be modified to make it complete. The staff shall advise the applicant: (2) if all required information is not submitted within 30 days, the project will be returned as incomplete. Any resubmittal of a returned application shall be accompanied with a new application fee." Please contact me with any questions that you may have regarding this request. *Please note that the fee for fast track sewer extension permits has increased to$600 as of October 3, 2023 [as stipulated in the 2023 House Appropriations Act, House Bill 259, Water Quality and Stormwater Fees, Section 12.14(a)]. Sincerely, https://outlook.office.com/mail/id/AAQkAGQ3ZGU4M2U4LTY2ZTUtNDhiMC04MGIyLTg2ZjEl NGVIMjk4MwAQAM9h238rRQ5Hp5okni1 UCCs%3D?nat... 2/3 9/12/24, 1:35 PM Mail-Pasha,Tanvir-Outlook A B M "Tanvir" Pasha (he/him) Environmental Engineer Division of Water Resources—Raleigh Regional Office North Carolina Department of Environmental Quality 3800 Barrett Drive, Raleigh, NC 27609 Office: 919-791-4250; Cell: 984-202-3390 tanvir.pasha@deq.nc.gov D--E NORTH CAROLINA Department of Environmental Duality Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. https://outlook.office.com/mail/id/AAQkAGQ3ZGU4M2U4LTY2ZTUtNDhiMC04MGIyLTg2ZjEl NGVIMjk4MwAQAM9h238rRQ5Hp5okni1 UCCs%3D?nat... 3/3