Loading...
HomeMy WebLinkAboutWS0701191_Application Extension_20240916Aiutrien, Feeding the Future - •ewb"-25,242W sePbmba-lGa2424 Attn: David May Division of Water Resources 943 Washington Square Mall Washington, NC 27889-3314 Subject: Application For Permit To Construct CCPCUA Permit No. CU1003 -Mine Depressurization Wells — Castile Hayne Aquifer PCS Phosphate Company, Inc." - Aurora Division Beaufort County Dear Mr. Tankard, Please see the attached application for well construction associated with systems regulated by Capacity Use Permit No. CU 1003 — Mine Depressurization Wells- Castle Hayne Aquifer. The application is for the addition of (7) Mine Depressurization Wells located south of 33. All wells will be located within the active mining area at the Nutrien — Aurora facility. Please do not hesitate to contact me at (252) 617-5374, if I can answer any questions, or provide any additional information concerning this application. I6frbi01 i Brittany Curtis Specialist, Environmental Affairs and Technical Services Nutrien-Aurora pc: 12-06-001-02 (w/attachment) cc: Gabrielle Chianese —DWR (w/attachment) Robbie Bullock — DWR (w/attachment) Tyler Cvetan (w/attachment) Emma Shipley (w/attachment) 1530 NC Hwy" S , Aumra. NC USA 21g08 1mmn.. m 1 Effective January 1. 2028, PCs Phosphate Company, Inc. is an indirect sulasidlary of Nutrien Ltd. PCS Phosphate Company, Inc, remalns the legal operating entity and permittee. NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY — DIVISION OF WATER p4S,OuRCES APPLICATION FOR PERMIT TO CONSTRUCT A WATER SUPPLY WELL OR WELL SYSTEM (Wells or Well Systems with a Design Capacity of 100,000 Gallons Per Day or Greater) PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct water supply wells. Z c-T ItMbed' 1. Date: 2. County: Beaufort FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE: 3. Applicant: PCS Phosphate Company Inc Telephone: 252-402-6044 Applicant's Mailing Address: 1530 NC HWY 306 S Aurora NC 27806 Applicant's Email Address (it available): Brittanv.Curtis(d-Mutrien com 4. Contact Person (if different than Applicant): Brittany Curtis Telephone: 252-322-4111 x8549 Contact Person's Mailing Address: 1530 NC HWY 306 S Aurora NC 27806 Contac Person's Email Address (if available): Brittanv.Curbs(a)nutrien com 5. Property Owner (if different than Applicant): Telephone: - Owner's Mailing Address: Owner's Email Address (if available): 6. Property Physical Address (including PIN Number): 1630 NC HWY 306 S PIN - 27806-9245 City: Aurora County: Beaufort Zip Code: 27806 7. Intended use of Well or Well System: Mine Depressurization Wells — Castle Havne Aquifer (examples: irrigation, consumption, etc.) 8. Will the proposed water supply well or well system replace or be added to an existing well orwell system? Yes (If yes, complete questions 7 and 8) (If no, complete question 7 and then skip to question 9) 9. Total design capacity of proposed well or well system in gallons per day (gpd): 78 000 000 10. If adding a well to an existing system, list the existing water supply wells in the existing system and their respective yields: These wells be regulated by CCPCUA Permit No. CU 1003 11. Is this a public well or well system? No If yes, give Public Water ID Number: If yes, give Project Engineer and contact information: 12. Well Contractor: Joshua Respess Well Contractor Certification No.: 4181-A Well Contractor Address: J.M. Hudson Drilling Co Inc 309 Teach's Cove Bath NC 27808 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(0(7), attach a well construction diagram of each well showing the following: 2. No. of wells to be constructed in unconsolidated a. Borehole and well diameter material: 0 b. Estimated well depth 3. No. of wells to be constructed in bedrock: 7 C. Screen intervals 4. Total No. of wells to be constructed: 7 d. Sand/gravel pack intervals (add answers from 2 and 3) e. Type of casing material and thickness 5. Estimated beginning construction date: 1/1/2024 f. Grout horizons 6. Estimated construction completion date: 12/31/2024 g. Well Head completion details Continued on Reverse ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(fx5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feel of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. C. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. 2. As required by 15A NCAC 02C .0105(g)(3), for wells screened in multiple zones or aquifers, provide representative data on the static water level, pH, specific conductance, and concentrations of sodium, potassium, calcium, magnesium, sulfate, chloride, and carbonates from each aquifer or zone from which water is proposed to be withdrawn. 3. Attach any water use permits (if required). [e.g. Central Coastal Plain Capacity Use Area Permit is required in 15 eastern NC counties by NC Division of Water Resources, visit: http://www.ncwater.org] SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of the Water Supply Well Construction Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina ; /�Administrative Code, Subchapter 2C) and accepts full responsibility for compliance with these rules ,! 1 n /" Specialist. Environmental & Technical Services Signature licant or *Agent Title of Applicant or *Agent Brittany Curtis • ff signing as Agent, attach authorization agreement stating Printed name of Applicant or 'Agent that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct water supply wells as outlined in this Water Supply Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the water supply well(s) conform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office Asheville Regional Office 3800 Barrett Drive Wilmington, NC 28405 2090 U.S. Highway 70 Raleigh, NC 27609 Phone: (910) 796-7215 Swannanoa, NC 28778 Phone: (919) 791-4200 Fax: (910) 350-2004 Phone: (828) 296-4500 Fax: (919) 571-4718 Fax: (828) 299-7043 Winston-Salem Regional Office Washington Regional Office 450 W. Hanes Mill Road Fayetteville Regional Office 943 Washington Square Mall Suite 300 225 Green Street, Suite 714 Washington, NC 27889 Winston-Salem, NC 27105 Fayetteville, NC 28301-5094 Phone: (252) 946-6481 Phone: (336) 776-9800 Phone: (910) 433-3300 Fax: (252) 975-3716 Fax: (336) 776-9897 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704)663-1699 Fax: (704)663-6040 Wilmington Regional Office GW-22W Rev. 3-1-2016 Raleigh Regional Office 127 Cardinal Drive Extension w Z i FIGURE 3 TYPICAL 20" DEPRESSURIZATION WELL CONSTRUCTION DIAGRAM STEEL CAP GROUND LEVEL SURFACE CASING 0' TO -34' - 60' (TOPOFCLAV - LAYER OR - SHELL BED) 0' TO 180' 28" BOREHOLE Alutrien- Feeding the Future +2' TO 0' 0' TO -20' CEIVENTGROUT -20' TO -160' DRILL CUTTINGS -160' TO -180' CEMENT GROUT -180' TO -260' 18" OPEN BOREHOLE +2' TO -180' 20" x .375" WALL STEEL CASING NOTE: Drawing not to scale. Casing lengths are approximate. Steel casing to be set at least 10' into the tap of the Castle Hayne Aquifer, which lies approximately 145'to 168' below land surface within the project area. Surface casings typically extend about 34 to 60 feet deep.