HomeMy WebLinkAboutNCC242846_Site Plan or Location Map_20240916 4,211....nwityg.
low•••••morsovele ,
11406.1qumrstlibraogiv2
f DUKE ___.,151 ._..........
mir--Aekvi-zAw 424,4---atv we '
s sE1411 /eirj
PROJECT %Till!� �►
LocATION
t 1 ittr,"
NfrA.. „,,,,to,„ ,,,.it
ENERGY® viphvir4
Irixt,
CAROL I NAS 10
NORTH & SOUTH CAROLINA STATE MAP
CHASTAIN LINE PERMITTING
PROJECT NARRATIVE CHARLOTTE, NC
THE PROPOSED CHASTAIN LINE PERMITTING PROJECT IS LOCATED IN MECKLENBURG COUNTY,NORTH CAROLINA.THE
PROJECT INCLUDES INSTALLATION OF THE WYLIE WHITE CIRCUIT(1W3208),WHICH WILL EXTEND NORTHEAST FROM NEW
TOWER 484 TO SERVE THE NEW CHASTAIN AVE RET SUBSTATION.THIS WILL INCLUDE APPROXIMATELY 750 FEET OF
DOUBLE CIRCUIT 795 ACSS/TW WITH TWO 3/8"HS OHGW'S.TOWER 484(1B+20 STRAIN)WILL BE REPLACED WITH A NEW
1 EWL+20BA,FOLDING IN OVER THE CHARLOTTE 1&244KV LINES.THE WYLIE B&W(1 W538/1 W3208)WILL ALSO BE
RECONDUCTORED WITH THE 795 ACSS/TW FROM TOWER 484 INTO WOODLAWN TIE(4 SPANS EQUALING 1010 FEET). IT IS
ASSUMED THAT ADEQUATE GROUND AND RR CLEARANCE CAN BE MAINTAINED WITH THE NEW CONDUCTOR,AND NO START E N D
OTHER STRUCTURES WILL REQUIRE REPLACEMENT.THE PROPOSED LIMITS OF DISTURBANCE IS 4.77 ACRES.IN ORDER TO ACCOUNT FOR ALTERNATIVE CONSTRUCTION METHODS,OR THE NEED FOR ACCESS TO OTHER TOWERS,AN LATITUDE: 3 5°1 0' $" LATITUDE: 3 5°1 0'14"
ADDITIONAL 10%OF TOTAL PROPOSED WORK AREA HAS BEEN INCLUDED IN THE PERMITTING FEE.THE ADDITIONAL10%
OF ACREAGE IS EQUAL TO 0.48 ACRES AND RESULTS IN A TOTAL AREA OF 5.25 ACRES.PRIOR TO CONSTRUCTION,A DUKE
ENERGY CONSTRUCTION CONTRACTOR WILL INSTALL EROSION AND SEDIMENT CONTROL MEASURES TO ENCOMPASS LONGITUDE: -80°53'0 5" LONGITUDE: -80°53'07 rr
THE ANTICIPATED CONSTRUCTION LIMITS.PREDEVELOPMENT CONDITIONS WILL BE RESTORED AND THE AREA WILL BE
STABILIZED PRIOR TO COMPLETION OF CONSTRUCTION.AN AVOIDANCE AND MINIMIZATION OF DISTURBANCE APPROACH
HAS BEEN INCORPORATED INTO THE DESIGN OF THE EROSION CONTROL MEASURES BY UTILIZING EXISTING ACCESS -Imesr� N SHEET LIST:
POINTS AND STABILIZED RIGHT-OF-WAY ACCESS ROUTES,WHENEVER POSSIBLE.EROSION CONTROL MEASURES ARE ., + j
INDICATED HEREIN FOR PERMITTING USE ONLY BY NCDEQ.THE INITIAL PROJECT DURATION IS ANTICIPATED TO START IN I 111:I-, TITLE SHEET SHEET PTL
SEPTEMBER 2024 AND BE COMPLETED IN AUGUST 2025. BILLY GRAHAM PKWY (SR-5901),s -.:-, EROSION&SEDIMENT CONTROL NOTES SHEET PEN1
;T ,A :"t m * T`► _ EROSION&SEDIMENT CONTROL NOTES SHEET PEN2
YORKMONT RD (SR 1156) z..
" • ," NATIONS CROSSING RD EROSION&SEDIMENT CONTROL EROSION&SEDIMENT CONTROL PLANS SHEET SHEET p1 PEN3
GENERAL NOTES # R i``
1. APPROXIMATE STRUCTURE LOCATIONS WERE PROVIDED BY DUKE ENERGY LINE ENGINEER AND ARE - '5,„ E WOODLAWN RD (SR-1291) EROSION&SEDIMENT CONTROL PLAN SHEET P2
s +
FOR REFERENCE ONLY. THESE DRAWINGS SHALL NOT BE USED FOR LINE CONSTRUCTION. S TRYON ST (SR-0049) _ " - r �►- EROSION&SEDIMENT CONTROL DETAILS SHEET PED1
2. BASE DRAWINGS WERE CREATED FROM GIS DATA OBTAINED FROM VARIOUS SOURCES.AERIAL EROSION&SEDIMENT CONTROL DETAILS SHEET PED2
,'+ E WOODLAWN RD (SR-3814) EROSION&SEDIMENT CONTROL DETAILS SHEET PED3
PHOTOGRAPHY WAS OBTAINED FROM STATE AGENCIES. NATIONS FORD RD m
3. NOT ALL EXISTING UTILITIES ARE SHOWN. LOCATIONS SHOWN ARE APPROXIMATE. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO ACCURATELY LOCATE,BOTH VERTICAL AND HORIZONTAL, l'•' - `.-SPRINGBROOK RD
EXISTING UTILITIES PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY NC BEGINNING OF CHASTAIN LINE PERMITTING
811 PRIOR TO EXCAVATION. CONTRACTOR SHALL NOTIFY DUKE ENERGY IMMEDIATELY IN THE EVENT a y ~ Ira s
OF ENCOUNTERING ANY UNDERGROUND OBSTACLE REQUIRING DEVIATION FROM THE PLAN. COST TO t - _
REPAIR DAMAGED UTILITIES SHALL BE BORNE BY THE CONTRACTOR. --
4. ALL UTILITIES SHALL BE PROTECTED AND REMAIN ACTIVE UNLESS OTHERWISE NOTED. CONTRACTOR I
` •s
SHALL NOT DISTURB UTILITY POLES,GUY WIRES,OR ANCHORS WITHOUT PERMISSION FROM DUKE i ,~ - MIGRATORY BIRD HOTLINE
: �r. •
ENERGY. - D MARKETPLACE
WOODLAWN MA E STATE AND FEDERAL LAWS PROTECT ALL SPECIES OF NATIVE BIRDS FOUND THROUGHOUT THE DUKE ENERGY
5. PROJECT IS LOCATED IN THE CATAWBA RIVER BASIN. THE PROJECT IS SUBJECT TO :_'. SERVICE AREA.INTERACTIONS OF BIRDS WITH GENERATING FACILITIES,TRANSMISSION AND DISTRIBUTIONS,
STATE-REGULATED BUFFER REQUIREMENTS. ° FBI 1 OLD PINEVILLE RD SUBSTATIONS,OTHER STRUCTURES AND EQUIPMENT,AND OPERATIONS ARE POTENTIALLY HARMFUL OR FATAL TO
6. SEE SHEET PEN1 FOR EROSION AND SEDIMENTATION CONTROL NOTES,CONSTRUCTION SEQUENCE, }• - !� - _ '� s... . BIRDS. DUKE ENERGY OPERATES THESE 24-HOUR MIGRATORY BIRD HOTLINES TO ASSIST EMPLOYEES AND
AND SEEDING SCHEDULE. ' ■ ° CONTRACTORS WITH RELATED INCIDENTS THAT OCCUR DURING WORK ACTIVITIES.
7. STREAMS EXTEND BEYOND THE RIGHT-OF-WAY. APPROPRIATE BRIDGING AND MATTING OF THESE )' _ y + '� SOUTH BLVD (SR-3998)
FEATURES IS REQUIRED SHOULD THE CONTRACTOR USE ANY ACCESS ROUTES LOCATED OUTSIDE OF .� �; ` I. CAROLINAS:JAMES MCRACKEN 704.996.8671 FLORIDA:727.386.3084 MIDWEST:317.430.4497
THE RIGHT-OF-WAY. r ti w YTS`r ' m ..� ', - - -
8. ANY ALTERNATE ACCESS PLANNED BY THE CONTRACTOR SHALL BE APPROVED BY DUKE ENERGY t �`��• - SPILL REPORTING HOTLINE
PERMITTING PRIOR TO USE. P' 77 CENTER DRIVE i. _.
END OF CHASTAIN LINE PERMITTING
9. CONSTRUCTION ENTRANCES ARE SHOWN FOR REFERENCE ONLY. HEAVY MATS MAY BE USED IN LIEU -. REQUIREIN OU TOT CERTAINSURE THE PROTECTIONEOFPIL SO AHND
UNPERMITTEDAN HEALTH AND THE ENVIRONMENT, D FEDERAL AND STATE LAWS
OF ROCK CONSTRUCTION ENTRANCES IF DEEMED SUFFICIENT BY A DUKE ENERGY REPRESENTATIVE. ® THAT TYPES OF SPILLS ANDFOLLOWING
RELEASES BE REPORTED TO THE PROPER
u` 1'` ,.� - REGULATORY AGENCIES AS SOON AS POSSIBLE FOLLOWING IDENTIFICATION.IMMEDIATELY NOTIFY YOUR
10. WETLAND MATTING SHALL BE COMPOSITE MATS. NO LATTICE OR TWO-PLY MATTING SHALL BE USED _ - 1 p RAILROAD
" SUPERVISOR AND THE FIELD ENVIRONMENTAUEHS PROFESSIONAL WHEN A SPILL OR UNPERMITTED RELEASE IS
IN JURISDICTIONAL WETLANDS AND/OR STREAMS. NVOLA RD (SR-1577) At *, ' DISCOVERED.IF YOU ARE UNABLE TO FIELD ENVIRONMENTAUEHS PROFESSIONALCONTACT ONE OF I 0
11. NO OIL/FUEL-FILLED EQUIPMENT SHALL BE STORED OVERNIGHT WITHIN 100 FEET OF WETLANDS OR '. '!+* •'®gyp 10 THE DUKE ENERGY SPILL REPORTING HOTLINES AT: Z
SURFACE WATER WITHOUT CONTAINMENT. t CAROLINAS&MIDWEST:800.527.3853 I-
12. SITE SHOULD BE"STORM READY"AT THE END OF EACH WORK DAY/WEEK. IAIm., - FLORIDA:866.769.1266 H
13. SECURE WRITTEN ACCESS AGREEMENT IS REQUIRED FOR ALL 3RD PARTY ACCESS AND PRIVATE 10 2
DRIVES NOT INCLUDED IN ROW DOCUMENTATION PRIOR TO BEGINNING CONSTRUCTION. CK
14. ALL DISTURBED AREAS SHALL BE RESTORED TO SAME OR BETTER CONDITION.PERMANENT GROUND VICINITY MAP CONTACTS LLI
COVER SHALL BE USED FOR STABILIZATION. JEFF GOTO ENGINEER: RESPONSIBLE FOR MAINTENANCE:
15. CONTRACTOR TO FIELD ADJUST CRANE AND PULL PADS AS NEEDED FOR SAFE ACCESS UNDER SCALE. 1"=1 000' DUKE ENERGY CAROLINAS HDR ERIC SHOOK W
EXISTING ENERGIZED ELECTRICAL OVERHEAD LINES. 525 SOUTH TRYON ST. MICHAEL LITTLE,PE PH:(336)416-9468 Z
CHARLOTTE,NC 28202 440 S.CHURCH STREET Eric.Shookduke-energy.com J
PH:(760)445-3332 SUITE 1200 Z
FAX:(704)382-6542 CHARLOTTE,NC
CONTRACTOR SHALL NOTIFY "NORTH CAROLINA ONE CALL' (811� Jeff.Goto@duke-energy.com PH:(704)338-6706 I-
OR (1-800-632-4949) AT LEAST 48 HOURS PRIOR TO michael.little@hdrinc.com U)
BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING Q
8
UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL I
UTILITIES THAT PROVIDED THEIR OWN LOCATOR SERVICES U
INDEPENDENT OR "NORTH CAROLINA ONE CALF. REPORT ANY "►+ '
DISCREPANCIES TO THE ENGINEER IMMEDIATELY. „oNN,rr„ DUKE TITLE
r`.•sy, AR07, CHASTAIN LINE PERMITTING
INC811.OAG� .OQ-`LESS/ �` F) HDR Engineering Inc.
u Id 1T oflheCarolinas ENERGY®SEAL TITLE SHEET
! 037911 ° 440 S.Church St.Suite 1200
1 re/ j(4,: Charlotte,NC 28202-2075 CAROLINAS
1 10375181 5/01/2024 90%ISSUED FOR REVIEW NC FSL BA O h01NEF'fi. .
0 10375181 2/2/2024 30%ISSUED FOR REVIEW NC FSL BA ,,,;9F1 G.°,,,, N.C.6.E.La.License Number 526 SOUTH CHURCH STREET NE INDEX DRANK SHEET
'rprrNnor�" F-0118 CHARLOTTE N.C.28202
REV FILE NO. DATE REVISION DRAWN CHECKED APPROVED TELEPHONE NO.(704)382-2741 10375181 PTL