Loading...
HomeMy WebLinkAboutWQ0036187_Permit (Issuance)_20121130"J NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Mr. Randy Hoffer Pluris, LLC 2100 McKinney Ave, Suite 1550 Dallas, Texas, 75201 Dear Mr. Hoffer: Division of Water Quality Charles Wakild, P.E. Director November 30, 2012 SUBJECT: Permit No. WQ0036187 Pluris, LLC 12th Avenue Sewer Extension Onslow County Dee Freeman Secretary In accordance with your permit application received October 11, 2012, and additional information received by the Division of Water Quality (Division), we are forwarding herewith Permit No. WQ0036187 dated November 30, 2012, to Pluris LLC for the construction and operation of the subject wastewater collection system. This Permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the approved plans and specifications. Mail the Certification to the Infrastructure Finance Section, 1633 Mail Service Center, Raleigh, North Carolina 27699-1633. (Engineer's Certification Form is attached.) One set of approved plans and specifications is being forwarded to you. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-6492 Internet: www.ncwaterouality.oro An Equal Opportunity 1 Affirmative Action Employer NorthCarolina Natumllry Mr. Randy Hoffer November 30, 2012 Page 2 If you need additional information concerning this matter, please contact Adrian Eaton, State Review Engineer, at (919) 707-9178 or Seth Robertson, P.E. at (919) 707-9175. Sincerely, Charles Wakild, P.E. ae/sr cc: Michael C. Gallant, P.E., Michael C. Gallant Engineering, P.O. Box 4039, Surf City, North Carolina, 28445 Onslow County Health Department DWQ Wilmington Regional Office, Surface Water Protection DWQ Wilmington Regional Office, Aquifer Protection Section (WQ0005849) Application File WQ0036187 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO PLURIS LLC Onslow County FOR THE construction and operation of a pressure sewer extension consisting of: approximately 70 linear feet of 2-inch pressure sewer, and one (1) simplex pump station with on -site audible and visual alarms to serve one (1) 4-bedroom single family residential unit as a part of the 12th Avenue Sewer Extension, and the discharge of 480 GPD of collected wastewater into the Pluris North Topsail WWTF (WQ0005849) sewerage system pursuant to the application received on October 11, 2012, and subsequent additional information received by the Division of Water Quality (Division), and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0400. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0400: Pluris LLC November 30, 2012 Permit No. WQ0036187 Page 2 (a) The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. (b) A map of the sewer system shall be developed and actively maintained. (c) An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response shall be developed and implemented. (d) Pump stations that are not connected to a telemetry system (i.e., remote alarm system) shall be inspected by the permittee or its representative every day (i.e., 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. (e) High -priority sewers shall be inspected by the permittee or its representative at least once every six -months and inspections are documented. (f) A general observation by the permittee or its representative of the entire sewer system shall be conducted at least once per year. (g) Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 02B .0506(a), and public notice shall be provided as required by G.S. 143-215.1C. (h) A Grease Control Program shall be established as follows: (i) For publicly owned collection systems, the Grease Control Program shall include at least bi-annual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors for new construction and retrofit, if necessary, of grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. (ii) For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permittee or its representative. (iii) Grease education materials shall be distributed more often than required in Parts (i) and (ii) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. (i) Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. (j) Documentation shall be kept for Subparagraphs (a) through (i) for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 4. The sewage and wastewater collected by this system shall be treated in the Pluris North Topsail WWTF (WQ0005849) sewerage system prior to being land applied. Pluris LLC November 30, 2012 Permit No. WQ0036187 Page 3 5. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Mail the Certification to the Infrastructure Finance Section, 1633 Mail Service Center, Raleigh, North Carolina 27699-1633. (Engineer's Certification Form is attached.) 9. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 10. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e., local, state, and federal) having jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, soil erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCGO10000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. The Permittee shall provide for the pump station and force main the following items: (a) Pump Station Reliability: (i) Pump stations, except when exempted by Subparagraph 0)(2) of 15A NCAC 02T.0305, shall be designed with multiple pumps such that peak flow can be pumped with the largest pump out of service. (ii) A standby power source or pump is required at all pump stations except for those pump stations subject to Subparagraph 0)(2) of 15A NCAC 02T.0305. Controls shall be provided to automatically activate the standby source and signal an alarm condition. Pluris LLC November 30, 2012 Permit No. WQ0036187 Page 4 (iii) As an alternative to Part (ii) for pump stations with an average daily design flow less than 15,000 gallons per day as calculated using 15A NCAC 02T.0114, a portable power source or pumping capability may be utilized. It shall be demonstrated to the Division that the portable source is owned or contracted by the permittee and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (iv) As an alternative to Part (ii) for pump or vacuum stations connecting a single building to an alternative sewer system, wet well storage requirements shall be documented to provide 24-hours worth of wastewater storage or, exceed the greatest power outage over the last three years or the documented response time to replace a failed pump, whichever is greater. Documentation shall be required pursuant to the permit application. (v) All pump stations designed for two pumps or more shall have a telemetry system to provide remote notification of a problem condition to include power failure and high water alarm. (vi) High water audio and visual alarm. (b) Pump stations shall have a permanent weatherproof sign stating the pump station identifier, 24-hour emergency number and instructions to call in case of emergency. Simplex pump or vacuum stations serving a single-family residence shall have a placard or sticker placed inside the control panel with a 24-hour emergency contact number. (c) Screened vents for all wet wells. (d) The public shall be restricted access to the site and equipment. (e) Air relief valves shall be provided at all high points along force mains where the vertical distance exceeds ten feet. 12. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those that may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 13. The facilities shall be constructed in accordance with the requirements of the North Carolina Sedimentation Pollution Control Act. 14. If applicable, the Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is made a condition of this Permit. Noncompliance with the terms of the Operational Agreement may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. A copy of the Articles of Incorporation, Declarations, and Bylaws that have been properly filed shall be submitted with the engineer's certification prior to operation. Pluris LLC November 30, 2012 Permit No. WQ0036187 Page 5 15. Any abandoning of the existing facilities must be done in accordance with the requirements of the Division's Wilmington Regional Office. 16. Noncompliance Notification: The Permittee shall verbally report to a water quality staff member at the Wilmington Regional Office, telephone number (910) 796-7215, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: (a) Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater transport such as mechanical or electrical failures of pumps, line blockage or breakage, etc. (b) Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858- 0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition I(2), Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 17. The Permittee shall maintain on hand for immediate installation an adequate supply of spare, fully operational pump units of each type used in the pressure sewer system. 18. Pursuant to the letter from the Town of North Topsail Beach, dated September 6, 2011 (see attached), an alternative to 15A NCAC 02T .0305 (e) is granted to allow the grinder pump station to be installed without protection from a 100-year flood. In the event that a storm could produce a 100-year flood event, the Town will declare a mandatory evacuation. Permit issued this the 30th Day of November 2012 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Charles Wakild, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit No. WQ0036187 Pluris LLC Permit No. WQ0036187 12th Avenue Sewer Extension Issued November 30, 2012 ENGINEERS CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the 121h Avenue sewer extension, located in Onslow County, hereby state that to the best of my abilities, due care and diligence was used in the observation of the following construction: a pressure sewer extension consisting of. approximately 70 linear feet of 2-inch pressure sewer, and one (1) simplex pump station with on -site audible and visual alarms to serve one (1) 4-bedroom single family residential unit as a part of the 12th Avenue Sewer Extension, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Date Registration No. Mail this Certification to: Attn: Adrian Eaton DENR/DWQ Infrastructure Finance Section 1633 Mail Service Center Raleigh, North Carolina 27699-1633. Note: If the wastewater collection permit was issued to a private entity under an Operational Agreement with the Environmental Management Commission, then a copy of the Articles of Incorporation, Declarations, and Bylaws that have been properly filed with the applicable County's Register of Deeds shall be submitted with this certification.