Loading...
HomeMy WebLinkAboutSW6231002_Design Calculations_20240906 (4) C*40\I,: NTECH. ENGINEERED SOLUTIONS Filterra Sizing in North Carolina Design Engineer: Irs Blue Cells= Input Date 8/20/2024 Black Cells= Calculation Site Information Project Name Serenity-SCM 12 Project State North Carolina Project Location Harnett County Drainage Area,Ad 1.42 ac Impervious Area,Ai 0.93 ac Impervious Runoff Coefficient,Ci 0.90 Pervious Area,Ap 0.49 Pervious Area Runoff Coefficient,Cp 0.30 %Impervious 65% Weighted Runoff Coefficient,Cw 0.69 Filterra Sizing Calculations Filter Surface Area/Drainage Area Ratio 0.39% Per NCDEQ Manual,Chapter D.3,Table 1 Required Filterra Media Surface Area, 185 ft2 Filterra System Filterra Configuration Bioscape Vault 2 ea - 8 x 12 Vaults Filterra Model ID See Note Note: Drainage area is too large for single Filterra system.Consider a different Filterra configuration, utilizing multiple structures,or utilizing Filterra Bioscape.Contact Contech for more info. ©2019 Contech Engineered Solutions ContechES.com 1 of 1