HomeMy WebLinkAboutForsyth_Well Abandonment_20240910 (2) WELL ABANDONMENT RECORD For Internal Use ONLY:
1.Well Contractor Information: WELL ABANDONMENT DETAILS
J. Michael Venable 7e.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same
Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of
N CW C-2079-A wells abandoned:
NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 261 (gal.)
Venable Brothers Well Const.r Inc. FOR WATER SUPPLY WELLS ONLY:
Company Name 7c.Type of disinfectant aced: Calcium Hypochlorite
2.Well Construction Permit#:
List all applicable well construction permits(i.e.UIC.County,State,Variance,etc.)ifknown
7d..amount of disinfectant used: OZ
3.Well use(check well use):
Water Supply Well: 7e.Sealing materials used(check all that apply):
❑Agricultural ❑Municipal/Public ❑Neat Cement ❑ Bentonite Chips or Pellets
❑Geothermal(Heating/Cooling Supply) ■Residential Water Supply(single) ❑ Sand Cement *���Hry Clay
❑Industrial/Commercial ❑Residential Water Supply(shared) III Concrete Grout �a Jrr kWil Cuttings
Oftrigation ❑Specialty Grout SEP 1 0 20240 Gtavel
Non-Water Supply Well: ❑Bentonite Slur ❑Other(explain under 7g)
❑Monitoring ❑Recovery ;ng I,ra
Injection Well: 7f.For each material selF�tfld fj}Y,pro�lde amoaoIt of materials used:
❑Aquifer Recharge ❑Groundwater Remediation well mix- 8 yards
❑Aquifer Storage and Recovery ❑Salinity Barrier
❑Aquifer Test ❑StormwaterDrainage clean clay- 1 yard
❑Experimental Technology ❑Subsidence Control 7g,Provide a brief description of the abandonment procedure:
❑Geothermal(Closed Loop) ❑Tracer removed plumbing; dewatered•
❑Geothermal(Heating/CoolingReturn ❑Other(explain under 7 ) P g> >
chlorinated; removed top 3 ft of tile;
°•Date well(a)abandoned: 8/29/2024 filled with well mix to form plug;
9;
sa.Well location: topped with clean clay
WESTCAR PROPERTIES,LLC/FRANK HERNANDEZ
Facility/Owner Name Facility ID#(ifapplicable) 8.Certification:
7113 HUNTING BROOK CT., WALKERTOWN, NC Q. 8/30/2024
Physical Address,City,and Zip Si of Certified Well Contractor or Well Owner Date
Forsyth 6869-74-1021 By signing this form, I hereby certify that the well(s)was(were)abandoned in
County Parcel Identification No.(PIN) accordance with 1 SA NCAC 02C.0100 or 2C.0200 Well Construction Standards
Sb.Latitude and longitude in degrees/minutes/seconds or decimal degrees: and that a copy of this record has been provided to the well owner.
(ifwell field one[at/long is sufficient) 9.Site diagram or additional well details:
36.201281 N -80.128098 µ, You may use the back of this page to provide additional well site details or well
abandonment details. You may also attach additional pages if necessary.
CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS
Attach well construction record(s)ifavailable. For multiple injection or non-water supply wells
ONLY with the same construction abandonment,you can submit oneform. 10a. For All Wells: Submit this form within 30 days of completion of well
6a.Well ID#: abandonment to the following:
Division of Water Resources,Information Processing Unit,
61).Tonal w cll depth: 67 (ft.) 1617 Mail Service Center,Raleigh,NC 27699-1617
lob.For Iniection Wells: In addition to sending the form to the address in 10a
6c.Borehole diameter: 24 (in.) above,also submit one copy of this form within 30 days of completion of well
abandonment to the following:
6d.Water level below ground surface: 51 (ft,) Division of Water Resources,Underground Injection Control Program,
1636 Mail Service Center,Raleigh,NC 27699-1636
6e.Outer casing length(if known): (ft,) 10c.For Water Supply&Iniection Wells: In addition to sending the form to the
address(es)above,also submit one copy of this form within 30 days of completion
of well abandonment to the county health department of the county where
6f.Inner casing/tubing length(if known): (ft.) abandoned.
6g.Screen length(if known): (ft)
Form G W-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016