Loading...
HomeMy WebLinkAboutSW6240607_Design Calculations_20240830 (3) NORTH North American Green AMERICAN 5401 St. Wendel-Cynthiana Rd. Poseyville, Indiana 47633 GREEN Tel. 800.772.2040 >Fax 812.867.0247 www.nagreen.com ECMDS v7.0 SLOPE ANALYSIS >>>ROAD B CUL-DE-SAC SLOPE Country United States State/Region North Carolina City Fayetteville Annual R Factor 300.00 Adjusted R Factor 255.00 Total Slope Length 20 Protection Type Permanent Protection Period 9 Beginning Month May Slope Gradient(H:1) 2 Soil Type Sandy Loam K Factor 0.19 Reach 1 Start: Oft End: 20 ft Vegetation Type: 50-64% Material ASL bare ASL mat MSL bare MSL mat Soil Loss SF Remarks Staple/App Tolerance Rate P300 0.6 in 0.0 in 1.1 in 0.0 in 0.25 in >10 STABLE D P300 1.1 in 0.0 in 1.7 in 0.0 in 0.03 in 3.008 STABLE D Reinf. Veg