Loading...
HomeMy WebLinkAboutWM0401549_Application_20240823NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: 2. County: Guilford FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE 3. What type of well are you applying for? (monitoring or recovery): Temporary monitoring well 4. Applicant: Murphy Oil USA Telephone: 704-860-3602 Applicant's Mailing Address: 9805 Katy Freeway Suite G-200 Houston, Texas 77024 Applicant's Email Address (if available): Caleb.Chambers6dWurphvUSA.com 5. Contact Person (if different than Applicant): Matthew Cowart Telephone: 470-896-0034 Contact Person's Mailing Address: 625 Holcomb Bridge Road, Norcross, GA 30071 Contact Person's Email Address (if available): mcowart(aunitedconsulting.com 6. Property Owner (if different than Applicant): Brian Hunt Telephone: 803-760-3088 Property Owner's Mailing Address: 34 Lata Palm Ct Blythewood, SC 29016 Property Owner's Email Address (if available): 7. Property Physical Address (Including PIN Number) 2403 Randleman Road City Greensboro County Guilford Zip Code 27406 8. Reason for Well(s): Phase II assessment, suspect contamination (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: On -site spills, adjoining fuel station, drycleaners, and auto store. (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). 11 12 13 14 Spill of approximately 75-gallons non -PCB mineral Oil from failed utility pole transformer. Incident # 200604060 Type of contaminants being monitored or recovered: VOCs, lead, and PAHs (ex: organics, nutrients, heavy metals, etc.) Are there any existing wells associated with the proposed well(s)? If yes, how many? Not to my knowledge Existing Monitoring or Recovery Well Construction Permit No(s).: Distance from proposed well(s) to nearest known waste or pollution source (in feet): On -site (100 feet) Are there any water supply wells located less than 500 feet from the proposed well(s)? Not to my knowledge If yes, give distance(s): 15. Well Contractor: George Bridger Certification No.: 2393-A Well Contractor Address: 609A Piner Road STE 607, Wilmington, NC 28409 PROPOSED WELL CONSTRUCTION INFORMATION As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons C. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated 5. How will the well(s) be secured? material: 5 Temporary monitoring well 3. Number of wells to be constructed in bedrock: 0 6. Estimated beginning construction date: 8/27/24 4. Total Number of wells to be constructed: 5 7. Estimated construction completion date: 8/27/24 (add answers from 2 and 3) ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. C. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant assumes total responsibility for ensuring that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. s Digitally signed by Caleb Chambers Caleb Chamber Date: 2024.08.1609:15:48-04'00' Project Manager Signature of Applicant or *Agent Caleb Chambers Printed name of Applicant or *Agent Title of Applicant or *Agent * If signing as Agent, attach authorization agreement stating that you have the authority to act as the Agent. If the property is owned by someone other than the Applicant, the property owner hereby consents to allow the Applicant to construct well(s) as outlined in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to ensure that the well(s) wil�ocated, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office Raleigh Regional Office Wilmington Regional Office 2090 U.S. Highway 70 3800 Barrett Drive 127 Cardinal Drive Extension Swannanoa, NC 28778 Raleigh, NC 27609 Wilmington, NC 28405 Phone: (828) 296-4500 Phone: (919) 791-4200 Phone: (910) 796-7215 Fax: (828) 299-7043 Fax: (919) 571-4718 Fax: (910) 350-2004 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 GW-22M/R (Rev. 5-26-2022) I -c- Jce; 4" Legend ENV Soil Boring it 0 ENV Soil Boring 1 Temp Well Property boundary r Source Urce of known or potential groundwater contamination . - Ft J 7j "71 r.1 I.If SIV fob' tt Ap fir V-1tv bolt t, W7 Wr 4 �.A r Ilk. W! 4 4V-,p UNITED WELL/PIEZOMETER LOG ER�OPOSED ID: WELL 1 L ID: CONSULTING" CLIENT: SITE LOCATION: CONSTR. START: Murphy Oil USA, Inc. 2403 Randleman Road, Greensboro, NC 8/27/2024 DRILLING METHOD: CONSTR. COMP: PROJECT NAME: Greensboro, NC (Randleman & Meadowview) Hollow Stem Auger 8/27/2024 PROJECT NUMBER: DRILLING CONTRACTOR AND EQUIP: DEVELOPMENT DATE: MPOIL-24-NC-08518-02 Bridger Drilling NA LOGGED BY: SAMPLING METHOD: STATIC GROUNDWATER DEPTH: Matthew Cowart Peristaltic pump Unknown d w t N U E LITHOLOGY SAMPLES SKETCH NOTES 0 REC Sample ID OVM 0 2 -9 4 6 8 10 12 14 16 18 20 1::� �• .; ;, ; i 22 24 ::•".• ::: :�;; • . 26 t�• 28 •::� :1 30 NOTES - Surface Elev.: Surface Completion: Filter Pack Type: Screen Length: Time of Drilling Stick-uD #20 Well Slot Sand 10 Feet Groundwater Level TOC Elev.: Riser Height (Surface): Well Diameter: Screen Slot Size: 11nch 0.001in 2a-Hour Groundwater Level Northing/Lat.: Annular Fill Type: Borehole Diameter: Bottom of Screen: Fill Soils 6.25Inches 30 Feet C Easting/Long.: Annular Sealant Type: Top of Screen: Bottom of Well: Development Groundwater Level Grout La er/Bentonite Seal 20 Feet 30 Feet UNITED WELL/PIEZOMETER LOG TP 1 OSED ID: TPEL1 ID: CONSULTING" CLIENT: SITE LOCATION: CONSTR. START: Murphy Oil USA, Inc. 2403 Randleman Road, Greensboro, NC 8/27/2024 DRILLING METHOD: PROJECT NAME: CONSTR. COMP: Greensboro, NC (Randleman & Meadowview) Hollow Stem Auger 8/27/2024 PROJECT NUMBER: DRILLING CONTRACTOR AND EQUIP: DEVELOPMENT DATE: MPOIL-24-NC-08518-02 Bridger Drilling NA LOGGED BY: SAMPLING METHOD: STATIC GROUNDWATER DEPTH: Matthew Cowart Peristaltic pump Unknown d w t N U E LITHOLOGY SAMPLES SKETCH NOTES 0 REC Sample ID OVM 0 2 4 6 8 10 12 14 16 18 20 1::� �• 22 24 ::•".• ::: :�;; • . 26 t�• 28 30 �: �:.•. c ; NOTES - Surface Elev.: Surface Completion: Filter Pack Type: Screen Length: Time of Drilling Stick-up #20 Well Slot Sand 10 Feet Groundwater Level TOC Elev.: Riser Height (Surface): Well Diameter: Screen Slot Size: IInch 0.001in 2a-Hour Groundwater Level Northing/Lat.: Annular Fill Type: Borehole Diameter: Bottom of Screen: Fill Solis 6.25Inches 30 Feet C Easting/Long.: Annular Sealant Type: Top of Screen: Bottom of Well: Development Groundwater Level Grout La er/Bentonite Seal 20 Feet 30 Feet 1 POSED ID: WELL UNITED WELL/PIEZOMETER LOG PROPOSED � L ID: CONSULTING" CLIENT: SITE LOCATION: CONSTR. START: Murphy Oil USA, Inc. 2403 Randleman Road, Greensboro, NC 8/27/2024 DRILLING METHOD: CONSTR. COMP: PROJECT NAME: Greensboro, NC (Randleman & Meadowview) Hollow Stem Auger 8/27/2024 PROJECT NUMBER: DRILLING CONTRACTOR AND EQUIP: DEVELOPMENT DATE: MPOIL-24-NC-08518-02 Bridger Drilling NA LOGGED BY: SAMPLING METHOD: STATIC GROUNDWATER DEPTH: Matthew Cowart Peristaltic pump Unknown d w t N U E LITHOLOGY SAMPLES SKETCH NOTES 0 REC Sample ID OVM 0 2 4 6 8 10 12 14 16 18 20 i �• 22 24 ::•".• ::: :�;; • . 26 28 30 . : NOTES - Surface Elev.: Surface Completion: Filter Pack Type: Screen Length: Time of Drilling Stick-up #20 Well Slot Sand 10 Feet Groundwater Level TOC Elev.: Riser Height (Surface): Well Diameter: Screen Slot Size: IInch 0.001in 2a-Hour Groundwater Level Northing/Lat.: Annular Fill Type: Borehole Diameter: Bottom of Screen: Fill Solis 6.25Inches 30 Feet C Easting/Long.: Annular Sealant Type: Top of Screen: Bottom of Well: Development Groundwater Level Grout La er/Bentonite Seal 20 Feet 30 Feet UNITED WELL/PIEZOMETER LOG PROPOSED ID: WELL ID: C-1 C-1 CONSULTING" CLIENT: SITE LOCATION: CONSTR. START: Murphy Oil USA, Inc. 2403 Randleman Road, Greensboro, NC 8/27/2024 DRILLING METHOD: CONSTR. COMP: PROJECT NAME: Greensboro, NC (Randleman & Meadowview) Hollow Stem Auger 8/27/2024 PROJECT NUMBER: DRILLING CONTRACTOR AND EQUIP: DEVELOPMENT DATE: MPOIL-24-NC-08518-02 Bridger Drilling NA LOGGED BY: SAMPLING METHOD: STATIC GROUNDWATER DEPTH: Matthew Cowart Peristaltic pump Unknown d w t N U E LITHOLOGY SAMPLES SKETCH NOTES 0 REC Sample ID OVM 0 2 4 6 8 10 12 14 16 18 20 1::� �• 22 24 ::•".• ::: :�;; • . 26 t�• 28 30 NOTES - Surface Elev.: Surface Completion: Filter Pack Type: Screen Length: Time of Drilling Stick-up #20 Well Slot Sand 10 Feet Groundwater Level TOC Elev.: Riser Height (Surface): Well Diameter: Screen Slot Size: IInch 0.001in 2a-Hour Groundwater Level Northing/Lat.: Annular Fill Type: Borehole Diameter: Bottom of Screen: Fill Solis 6.25Inches 30 Feet C Easting/Long.: Annular Sealant Type: Top of Screen: Bottom of Well: Development Groundwater Level Grout La er/Bentonite Seal 20 Feet 30 Feet UNITED WELL/PIEZOMETER LOG PROPOSED ID: PWE2LL ID: CONSULTING" CLIENT: SITE LOCATION: CONSTR. START: Murphy Oil USA, Inc. 2403 Randleman Road, Greensboro, NC 8/27/2024 DRILLING METHOD: CONSTR. COMP: PROJECT NAME: Greensboro, NC (Randleman & Meadowview) Hollow Stem Auger 8/27/2024 PROJECT NUMBER: DRILLING CONTRACTOR AND EQUIP: DEVELOPMENT DATE: MPOIL-24-NC-08518-02 Bridger Drilling NA LOGGED BY: SAMPLING METHOD: STATIC GROUNDWATER DEPTH: Matthew Cowart Peristaltic pump Unknown d w t N U E LITHOLOGY SAMPLES SKETCH NOTES 0 REC Sample ID OVM 0 2 4 6 8 10 12 14 16 18 20 1::� �• 22 24 ::•".• ::: :�;; • . 26 t�• 28 30 NOTES - Surface Elev.: Surface Completion: Filter Pack Type: Screen Length: Time of Drilling Stick-up #20 Well Slot Sand 10 Feet Groundwater Level TOC Elev.: Riser Height (Surface): Well Diameter: Screen Slot Size: IInch 0.001in 2a-Hour Groundwater Level Northing/Lat.: Annular Fill Type: Borehole Diameter: Bottom of Screen: Fill Solis 6.25Inches 30 Feet C Easting/Long.: Annular Sealant Type: Top of Screen: Bottom of Well: Development Groundwater Level Grout La er/Bentonite Seal 20 Feet 30 Feet