Loading...
HomeMy WebLinkAboutWI0400629_Notification of Intent (NOI) – GW Remediation_20240802 CDM Smith July 30, 2024 Blake Butcher, Geologist/Hydrogeologist Groundwater Resources Branch— UIC Program Division of Water Resources—Water Planning Section North Carolina Department of Environmental Quality 1636 Mail Service Center Raleigh, NC 27699 Subject: Notification of Intent (NOI)to Construct and Operate Injection Wells Permit Type: (5) Pilot Test Kitchens Operation Center, Greensboro, North Carolina Dear Mr. Butcher: CDM Smith has submitted an NOI to the North Carolina Department of Environmental Quality (NCDEQ) DWR—UIC Program to perform aquifer testing at the Kitchens Operation Center site located in Greensboro, North Carolina. We are providing you with this letter containing additional information because you have served as the reviewer on this project previously and have requested the information herein. A conceptual remedial design for volatile organic compounds (VOCs) in groundwater has been completed for this site that includes constructing a treatment barrier at the property line to treat groundwater before it migrates offsite. Bioremediation will be used for treatment in the barrier and the injection of bioremediation agents will require a Groundwater Remediation Permit to construct and use wells for injection. Aquifer testing is planned under this NOI to provide the hydrogeologic data necessary to finalize the remedial design and prepare the Groundwater Remediation Permit.This aquifer testing NOI includes the "Deemed Permitted GW Remediation (NO1) Form (Rev. 3-1-2023)" in Attachment A and additional information below to address previous NCDEQ requests and compliance with 15A NCAC Subchapter 02C Rule .0220—Aquifer Test Wells.This rule defines "Aquifer Test Wells" as "...wells used to inject uncontaminated fluid into an aquifer to determine the aquifer characteristics." Aquifer Test Summary The existing and proposed well locations are shown on Figure 1 and Figure 2.The following sequence of work will be completed to support and complete the aquifer testing. 1. Obtain well construction permits from the Guilford County Health Department. 2. Well Installation a. Record boring logs, 6 boreholes b. Install/develop saprolite/partially weathered rock (PWR) aquifer test wells,4 each c. Install/develop shallow bedrock aquifer test wells,4 each d. Install/develop shallow bedrock monitoring wells, 2 each e. Submit GW-1 Well Construction Records ■ 5400 Glenwood Avenue,Suite 400, Raleigh, North Carolina 27612 1 tel:919 787-5620 CDM Smith Blake Butcher July 30, 2024 Page 2 3. Collect baseline samples from all new wells for VOC analyses 4. Construct a temporary potable water line from a fire hydrant to supply aquifer test water to the aquifer test wells 5. Complete 4.5-hour step tests on 4 saprolite/PWR aquifer test wells and 4 shallow bedrock aquifer test wells 6. Complete 48-hour constant rate tests on 2 saprolite/PWR aquifer test wells Subsurface Conditions A hydrogeologic cross section through the site is shown on Figure 3 and the cross-section location is shown on Figure 1. Groundwater flow from the site is to the south-southwest toward Buffalo Creek.The following subsurface zones have been investigated at the site. Overburden—Two overburden types were observed at the site: 1) an upper layer consisting of residual soil and fill and 2) a lower layer consisting of saprolite.The site topography has been altered by development and flat terraces have been graded along the slope leading down to South Buffalo Creek.The upper surface includes residual soil and fill and this material does not extend to depths below the water table.The saprolite consists of the in-place weathered material that retains remnant bedrock structure and consists primarily of micaceous silty sand, clayey sand, sandy clay, clay with rock fragments, and clayey silt.The water table is in the saprolite at a depth of approximately 20 feet below land surface (bls). PWR—The transitional zone between bedrock and saprolite originating from the partial weathering of the parent bedrock. Bedrock—Competent bedrock underlying the overburden consisting of metamorphosed granitic rock. Well Installation All wells will be installed using sonic drilling techniques and continuous formation samples will be collected and recorded on boring logs. Figure A-1 included with the attached NOI shows the planned well construction materials and completion depths. The wells will be constructed by methods that will ensure mechanical integrity.The borehole will be constructed using sonic drilling with a steel casing open for the full depth of the boring for installation. Well materials will be installed and depths verified before the steel casing in withdrawn.The cement/bentonite grout will be installed using the tremie pipe method in continuous operation until the complete well annulus is filled. Grout will be allowed to cure for a minimum of 48 hours before any injections are attempted. Visual checks will be made for mechanical integrity as injection is initiated and the injection pressure will be increased incrementally. Any conditions indicative a mechanical integrity problem will cause injections to cease and the next course of action will be determined. Aquifer Testing Two types of aquifer performance tests will be completed.The first test is a 4.5-hour step test. Separate step tests will be performed using the saprolite/PWR and bedrock test wells to determine well capacity 5400 Glenwood Avenue,Suite 400, Raleigh, North Carolina 27612 1 tel:919 787-5620 CDM Smith Blake Butcher July 30, 2024 Page 3 and formation transmissivity.The second test is a 48-hour constant rate test performed for saprolite/PWR to obtain addition aquifer parameters such as hydraulic conductivity and specific yield. The aquifer test setup is shown on Figure 4. The step tests will consist of injecting potable water at 3 flow rates for approximately 90 minutes at each flow rate while recording water levels, injection pressure, and flow.The tests will be conducted with steps at 3, 6, and 10 gallons per minute (gpm) and will not exceed 10 pounds per square inch (psi) measured at the wellhead.The flow rates will be adjusted as required by the observed pressure responses to flow but the maximum injection rate will not exceed 10 gpm.The anticipated test parameters are summarized below and the total injection radii are shown on Figure 2. Table 1:Aquifer Test Parameters Step Test Constant Constant Total Average Step Test Rate Test Rate Test Screen Effective Injection Well Rate Volume Rate Volume Length Porosity Radius INJ-1S 6.33 gpm 1,709 gal. 10 gpm 28,800 gal. 15 feet 20% 20.8 feet INJ-2S 6.33 gpm 1,709 gal. None None 15 feet 20% 4.9 feet INJ-3S 6.33 gpm 1,709 gal. None None 15 feet 20% 4.9 feet INJ-4S 6.33 gpm 1,709 gal. 10 gpm 28,800 gal. 15 feet 20% 20.8 feet INJ-11) 6.33 gpm 1,709 gal. None None 20 feet 15% 4.8 feet INJ-213 6.33 gpm 1,709 gal. None None 20 feet 15% 4.8 feet INJ-31) 6.33 gpm 1,709 gal. None None 20 feet 15% 4.8 feet INJ-413 6.33 gpm 1,709 gal. None None 20 feet 15% 4.8 feet If you have any questions or need any additional information, please contact me at your earliest convenience at (919) 325-3569 or by email at colonemf@cdmsmith.com. Sincerely, %&4 IVJLI-- Mathew F. Colone, P.G., PMP Associate CDM Smith Inc. cc: Eddie Raynard, City of Greensboro Virginia Spillman, City of Greensboro Tom Duffey, CDM Smith Inc. 5400 Glenwood Avenue,Suite 400, Raleigh, North Carolina 27612 1 tel:919 787-5620 Figures ■ 5400 Glenwood Avenue,Suite 400, Raleigh, North Carolina 27612 1 tel:919 787-5620 I Scale in Feet E. , y 0 150 300 MW 7 'ice . I �� "I I +►t g *"***O%IMW-30s¢, MW-29d• +`4 �:..--. t t . I ~ 4b , 4 MW-38s#. i 1 • �► ti .L _ �, ! �MW-34s' 4 T l T 1. ( ;";': i"-, / NJ ID MW-39s ( ) rIr M1Y49U f -MW-42s 'I r I I a MW-43dAil r a 1 r w MW 45d rMW-44s — r• •r fti r lei '� X: t'• ' -- b- i�r r L � � • � � I :.,:fi gip. � rJ e'��. n•'�T�t I F MW-47 w-ass W-s - W-1 it I Site Boundary Offsite Parcels Existing Well Proposed Well cross section __ _ - - - - Figure 1 CDMSaprolite Monitoring Well Shallow Bedrock Monitoring Well Well Location Map DM_ �` Saprolite/PWR Monitoring Well X Shallow Bedrock Injection Well Kitchens Operation Center Saprolite/PWR Injection Well -* Deep Bedrock Monitoring Well Greensboro, North Carolina N • ' Scale in Feet ♦ Cr E ♦ �� .�^ 0 60 120 ♦ (i7 r s ♦ (-F n $1 r--� 1 r MW-32d?:-BMW-31s off-) MW-41d IV) ' �r ,onI� 0-1 1� 1 t�� •a - , � J or fro ire-I k NW INJ-IS- INJ-1D / MW-35s MW-48d / NJ-2D D IN -2 -49d MW- 1 � '�T/ rli��t , � • rr► WNW M1 f / MWi24s MW 25d 1~ :;fMW-26d Site Boundary Existing Well Proposed Well cross section Off site Parcels — — — — Potable Water Figure 2 CDMSaprolite Monitoring Well Shallow Bedrock Monitoring Well Injection Diameter Aquifer Test Area Smith Saprolite/PWR Monitoring Well X Shallow Bedrock Injection Well J.Edward Kitchen Operations Center Saprolite/PWR Injection Well Deep Bedrock Monitoring Well Greensboro, North Carolina • "ISO • :11 Site :• •. :1 Meadowview �r Road City of Greensboro BDL 26 1 1 �1 -.�/... j�.r..../i✓!�� :'//�%/lF}i/� 7/0p,wg /��J//'L�•/I��...�.1fi%O/i/ijjil�/�n�/��/I/<-'vr/��//L/.�%/�%%1'��� �� ' / /�r� Pr/)ooiFFJI IFEN NOWN ON MENOMONEE "'Orm �i 'G+ !/ �/�I:/ // �MIN®R, , � fylyri//r I ti h6G' /�0=////lf�/1��riiior�r'�1�///• /f////l��//��� �// 1 11 11 11 • 11 11 •11 11 :11 •11 111 11 11 11 �11 11 •11 11 :11 •11 111 11 11 11 �11 11 --*-2019 PCE —Site Boundary MOM • '■■■■■■■■■■■■ ■■■■■■■■-m30 �■ 1 11 11 11 � 11 11 •11 11 :11 •11 111 11 11 11 •11 11 •11 11 :11 •11 111 11 11 11 • 11 Transducer Cable Cable — Gland � Pressure Potable Flow Gauge Water Totalizing Control Supply Flow Meter Valve - = = = = = = = = = = = =--=--=--=--=--=--=--= ---=--=--=--=--=--=--- -----=--=--- ------------------------ --=--=--=--=- = ;_=________________________________ = _________________ _______________ ________ ___ __ ______ = = = = = = = _ _________ ___ ____________________ _______ ____ _____ _ --_--__-____--__-__________: ---------------=-=-==-----=-==-----=--=-=--==--=---=-------------==-----==--=--=------==--=-==-----==------=--==--=====--==--==---=----------==-=--==-------=--=--== --_______-_-___=_=====_===========____ _______ ______________________________________________________________________________________________________________________________________________________ t-:=_=____________ ____-_____; ___________________________________________________________________________________________________________________________________ ___________________________-____ _____ _ _ ____ =__-__-_ ________-__-____________. _ _ _ _ _ _ _ _ _ _ _ = = __-___-__________________ --------- -------------------------------------------------------------------------------------------------------------------------------------- Figure 4 Aquifer Test Setup CDM J.Edward Kitchen Operations Center Smith Greensboro, North Carolina I� -r- -�rrrr N ❑� MW-37s I 771.95 M MW-36s 770.21 3 772.24 t I .21 L 770 38 766.04 MW-34s 761.54 MW-31s j761.82 . 760 j MW-35s / MW-3_ 3s MW-39s• ' 755.72 752.77 756.56• 1 I T / • L . E � ❑I MW-42s 750 n r ❑ ❑IE 752.79 1 % MW-24s I I 1 � 750.28 a�i/ I a� 3 _. ul t 750 / I � U) ' ❑ W Meadow Rd. 74 t - - — •/� I L - 1 — -� � I— .l _ . — . . III MW-44s - - • . — .� — . . i - � � -- - - - 739.72 t 740 i1 1 MW-46s 729.74 ' I MW-28 I 4a/0 C, - � —7 n Scale in Feet 0 300 600 I ' i Site Boundary Cross Section Saprolite/PWR Figure 5: Saprolite/PWR Offs ite ar Pcels Potentiometric Surface Saprolite/PWR Monitoring Well 750 Potentiometric Surface Shallow Bedrock Monitoring Well Contour Interval=10 Feet SmithA Surface Water Contour Interval=2 Feet Kitchens Operation Center PWR-Partially Weathered Rock February 2023 Greensboro, North Carolina 0 -rrrrrr N �- •�. .LI L°j Ell o ��� ci I 770 � �! � S • MW-29d I —� 768.80 '* r� i I� MW-40d I J 762.14 MW-32d 760.7 - • / �E1 ❑I MW-25d I r M NA 6a ' j50 750.01 ❑ °❑IE c I I MW-43d 753.99 -- �� n 1 �� \ J/ I� y� MW-212 II I LKE741. 1 I — I— W Meadow Rd. A 740 M 5 739.4 u 730 — I / I I I I \ ----- M 7.16 - - - I I __— 717.1s I Se I - 4n`a/o C�ee / — I \ I— — \�A - Scale in Feet 0 300 600 i Site Boundary Bedrock Offsite Parcels Potentiometric Surface Figure 6: Bedrock — . . — . Cross Section — — — ' 750 Potentiometric Surface Contour Interval=10 Feet Smith Shallow Bedrock Monitoring Well Contour Interval=2 Feet Kitchens Operation Center Greensboro, North Carolina February2023 !—r-f—f �—�—r r _ N Lj W-.6 ' C I MW-36s I w E ❑� I MW-37s� �1y'2.11 • ND I NIDS 1 ` MND 3 I I S I I 8,140 MIP-21 I I / 21* l. — I MW-38s� � � /6.5 MW- 0 \ El 1,240 IMW-35s / 509 MW-39s - r205 / /MINp*0 /M /IP-19. 11.21 I / 0 ' 872 ND* u ❑ MW-42s ' IE ND I tMW-24s/ c I� i❑ 68.9 U _J I � d I la � L _. _ . L . _ _ W Meadow Rd. ` — ¢MW-44s — a I � Loy � � ro I MW-46s ND* MW-28 Se 10*1 \0io creek �J 1001, \ S11.9 11.9 SW-1 ND Scale in Feet 0 300 600 Site Boundary -(�Saprolite/PWR Monitoring Well PCE>Residential VISL, 12 ug/L Offsite Parcels `Shallow Bedrock Monitoring Well Figure 7: Saprolite/PWR 0 Surface Water PCE-Non-Residential VISL,48�g/L — — — — — — Tetrachloroethene (PCE) CDM Kitchens Operation Center Smith PWR-Partially Weathered Rock Posted values are PCE in ug/L Greensboro, North Carolina ND-Not Detected *-Sample prior to 2023 l—r—�—rrrrr _ N I L �LJI 1Ji E7,ciI I W E MW-29d• I i S . / 5,050 II / MV% I 1,450 / MW-41d I 2,300 i / El . - M 1890d I • 11EI ❑I I , N. . �. . �L . _ . . - . . -. I I MW-25d °' ID i❑IE MW-43d MW-26d 80.7 I 1.6 2,040 w = _ d , I I MW-27d 21.2 ElLI W Meadow Rd. 1 ` MW-45d I I I � 448 -LOYr--T ro I � I 0 MW-47d83 I - e4 I a/o I \•creek ,�at� Scale in Feet 0 300 600 Site Boundary Shallow Bedrock Monitoring Well PCE>100 ug/L Offsite Parcels Deep Bedrock Monitoring Well � � � � � - Figure 8: Bedrock CDM _ PCE>500 ug/L _ Tetrachloroethene (PCE) Posted values are PCE in u /L Smith g Kitchens Operation Center ND-Not Detected PCE>1,000 ug/L Greensboro, North Carolina Attachment A Deemed Permitted GW Remediation (NOI) Form ■ 5400 Glenwood Avenue, Suite 400, Raleigh, North Carolina 27612 1 tel:919 787-5620 NC Department of Environmental Quality (DEQ)—Division of Water Resources (DWR) NOTIFICATION OF INTENT (NOI) TO CONSTRUCT OR OPERATE INJECTION WELLS The following are `permitted by rule"and do not require an application to be submitted and an individual permit be issued when constructed in accordance with the rules of 15A NCAC 02C.0200(NOTE: This form must be received at least 14 DAYS prior to iniection) GROUNDWATER(GW)REMEDIATION INJECTION PERMIT TYPES: (1)IN-SITU GW REMEDIATION PERMIT TYPE(15A NCAC 02C.02251 • In-Situ Passive Injection Systems-In-well delivery systems to diffuse injectants into the subsurface. Examples include ORC socks,iSOC systems,and other gas infusion methods(Note:Injection Event Records(IER)do not need to be submitted for replacement of each sock used in ORC systems). • In-Situ Small-Scale Injection Operations—Injection wells located within a land surface area not to exceed 10,000 square feet(SF)for the purpose of soil or groundwater remediation or tracer tests.If area to be treated exceeds 10,000 SF do not use this NOI;an injection Permit application shall be submitted,and a Permit issued per 15A NCAC 02C.0225(f). • In-Situ Pilot Tests-Preliminary studies conducted for the purpose of evaluating the technical feasibility of a remediation strategy to develop a full-scale remediation plan for future implementation,and where the surface area of the injection zone wells is located within an area that does not exceed five percent of the land surface above the known extent of groundwater contamination. Also,if pilot test is going to be conducted on separate groundwater contaminant plumes do not use this NOI;a Permit application shall be submitted,and a Permit issued as per 15A NCAC 02C.0225(f). • In-Situ Thermal(IST)—IST wells`heat'contaminated groundwater in-situ to enhance remediation. (2)AIR INJECTION PERMIT TYPE 05A NCAC 02C.02251 These permit types are used to inject ambient air to enhance treatment of soil or groundwater. (3)TRACER WELL PERMIT TYPE(15A NCAC 02C.0229) These permit types are used to inject substances for determining hydrogeologic properties of aquifers. (4)AQUIFER TEST PERMIT TYPE(15A NCAC 02C.02201 These permit types are used to inject uncontaminated fluid into an aquifer to determine aquifer hydraulic characteristics. DATE: ,20 NOI TRACKING NO. (To be filled in by DWR) DIRECTIONS- Submit this NOI only for(1)New deemed `permitted by rule' injection project or(2)If there is going to be a different permit type(listed above)used for a previously issued NOI. NOTE-After this NOI is processed and acknowledged,any supplemental or additional injections still meeting the criteria referenced in Section G below shall be reported using Injection Event Records(IERs)and using the NOI tracking number provided by DWR. A. WELL TYPE TO BE CONSTRUCTED OR OPERATED (1) Air Injection Well....................................... Complete sections B through F,J,M (2) Aquifer Test Well.......................................Complete sections B through F,J,M (3) Passive Injection System............................... Complete sections B through F,H-M (4) Small-Scale Injection Operation...................... Complete sections B through M (5) X Pilot Test................................................. Complete sections B through M (6) Tracer Injection Well................................... Complete sections B through M (7) In-Situ Thermal(IST)Well........................... Complete sections B through M Deemed Permitted GW Remediation NOI Rev.3-1-2023 Page 1 B. STATUS OF WELL OWNER: County Government C. WELL OWNER(S) — State name of Business/Agency, and Name and Title of person delegated authority to sign on behalf of the business or agency: Name(s): City of Greensboro—Virginia Spillman,Assistant Director,Water Resources Department Mailing Address: PO Box 3136 City: Greensboro State:NC Zip Code: 27402-3136 County: Guilford Day Tele No.: 336-373-7779 Cell No.: EMAIL Address: claudia.spillman(a)greensboro-nc.gov Fax No.: D. PROPERTY OWNER(S)(if different than well owner/applicant) Name and Title: Company Name Mailing Address: City: State: Zip Code: County: Day Tele No.: Cell No.: EMAIL Address: Fax No.: E. PROJECT CONTACT(Typically Environmental Consulting/Engineering Firm) Name and Title: Mathew Colone—Project Manager Company Name CDM Smith Inc. Mailing Address: 5400 Glenwood Avenue, Suite 400 City: Greensboro State:NC Zip Code: 27612 County:Wake Day Tele No.: 919.325.3569 Cell No.: 919.609.2955 EMAIL Address: colonemf(a,cdmsmith.com Fax No.: F. PHYSICAL LOCATION OF WELL SITE (1) Facility Name&Address: City of Greensboro—Kitchen Building City: Greensboro County:Guilford Zip Code: 27406 (2) Geographic Coordinates: Latitude": 0 1 "or 36 0.0419757 Longitude": "or -79 0.7930471 Reference Datum:North American 1983 Accuracy: 0.1 Feet Method of Collection: Calculated geographic center of property "FOR AIR INJECTION AND AQUIFER TEST WELLS ONLY: A FACILITY SITE MAP WITH PROPERTY BOUNDARIES MAY BE SUBMITTED IN LIEU OF GEOGRAPHIC COORDINATES. G. TREATMENT AREA Land surface area of contaminant plume: —867,800 square feet Land surface area of inj.well network: —21,800 square feet(< 10,000 ft2 for small-scale injections) Percent of contaminant plume area to be treated: —2.5% (must be<5%of plume for pilot test injections) Deemed Permitted GW Remediation NOI Rev.3-1-2023 Page 2 H. INJECTION ZONE MAPS—Attach the following to the notification.—Maps attached and included in cover letter. (1) Contaminant plume map(s) with isoconcentration lines that show the horizontal extent of the contaminant plume in soil and groundwater, existing and proposed monitoring wells, and existing and proposed injection wells; and (2) Cross-section(s)to the known or projected depth of contamination that show the horizontal and vertical extent of the contaminant plume in soil and groundwater, changes in lithology, existing and proposed monitoring wells,and existing and proposed injection wells. (3) Potentiometric surface map(s)indicating the rate and direction of groundwater movement,plus existing and proposed wells. I. DESCRIPTION OF PROPOSED INJECTION ACTIVITIES AT THE SITE —Provide a brief narrative regarding the cause of the contamination,and purpose,scope,goals of the proposed injection activity:See cover letter. J. WELL CONSTRUCTION DATA (1) No.of injection wells: 8 Proposed 0 Existing(provide NC Well Construction Record(GW-1)for each well) (2) Appx. injection depths(BLS): Saprolite/PWR wells 20—35 ft BLS,Bedrock wells 40—60 ft BLS (3) For Proposed wells or Existing wells not having GW-1s,provide well construction details for each injection well in a diagram or table format. A single diagram or line in a table can be used for multiple wells with the same construction details. Well construction details shall include the following(indicate if construction is proposed or as-built): (a) Well type as permanent,Geoprobe/DPT,or subsurface distribution infiltration gallery (b) Depth below land surface of casing,each grout type and depth, screen,and sand pack (c) Well contractor name and certification number Well diap-ram attached. K. INJECTION SUMMARY NOTE: Only iniectants approved by the epidemiology section of the NC Division ofPublic Health,Department of Health and Human Services can be injected. Approved iniectants can be found online at http:Hdeg.nc.gov/about/divisions/water-resources/water-resources-permits/wastewater-branch/ground-water- protection/ground-water-approved-injectants. All other substances must be reviewed by the DHHS prior to use. Contact the UIC Program for more info iyou wish to get approval for a deferent additive. However,please note it may take 3 months or lonzer. If no iniectants are to be used use N/A. Injectant: NA Total Amt.to be injected(gal)/event: Injectant: NA Total Amt.to be injected(gal)/event: Injectant: NA Total Amt.to be injected(gal)/event: Injectant: NA Total Amt.to be injected(gal)/event: Injectant: NA Total Amt.to be injected(gal)/event: Total Amt.to be injected(gal/event): Deemed Permitted GW Remediation NOI Rev.3-1-2023 Page 3 No.of separate injection events: Total Amt.to be injected(gal): Source of Water(if applicable): City of Greensboro municipal water L. MONITORING PLAN—Describe below or in separate attachment a monitoring plan to be used to determine if violations of groundwater quality standards specified in Subchapter 02L result from the injection activity. Injecting_potable water to perform aquifer performance testing. Following well installation and aquifer performance testing a comprehensive round of groundwater samples will be collected from all wells at the site. The wells will be sampled for volatile organic compounds(VOCs)by EPA Method 8260. M. SIGNATURE OF APPLICANT AND PROPERTY OWNER Well Owner/Applicant: "I hereby certify, under penalty of law, that I am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, 1 believe that the information is true, accurate and complete. 1 am aware that there are significant penalties, including the possibility of fines and imprisonment, .for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurtenances in accordance with the 1 SA NCAC 02C 0200 Rules." Signaturevof Applicant Print or Type Full Name and Title Property Owner(if the property is not owned by the Well Owner/Applicant): "As owner of the property on which the injection wells)are to be constructed and operated, I hereby consent to allow the applicant to construct each injection well as outlined in this application and agree that it shall be the responsibility of the applicant to ensure that the injection well(s) conform to the Well Construction Standards (I5A NCAC 02C.0200J." "Owner"means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land shall be deemed to vest ownership in the land owner, in the absence of contrary agreement in writing. Signature*of Property Owner(if different from applicant) Print or Type Full Name and Title *An access agreement between the applicant andproperty owner may be submitted in lieu of a signature on this form. Please send 1 (one)hard color copy of this NOI along with a copy on an attached CD or Flash Drive at least two(2)weeks prior to injection to: DWR—UIC Program 1636 Mail Service Center Raleigh,NC 27699-1636 Telephone: (919)707-9000 Deemed Permitted GW Remediation NOI Rev.3-1-2023 Page 4 1 • • 1 1 • � ��/ UAi •rif!///i� /L/iry � //�niii ,f ,(wir�(/,7 - w/`/��s�i1�//�/V�i,J►/I��"//%�/i/�Jj/ ,ram✓/_ � /O r�� , .,_ /io/` r /// /yi NO Me" / � VO— FA ofop �ilrii:I raj".�,10-%/ir ,Wells are to be installed by M&W Drilling, ;7,IvIuIuple NC certified drillers are employed by nn-Mr, &r '/M&W and the selected driller for this work will �uri OVA KA 110 1 o." 0 M IN ZW "r be iderILIfied on the GW-1 Well Construction ias�iii�/ �/////G_1/1h!►ri���J///���iiiaaiir/���%/�/..�ii���%11s'Y/�iiiai��iiir ... „ � �.. !