Loading...
HomeMy WebLinkAboutBIMS form WQCS00270-CEI 2024 Docusign Envelope ID:06107E31-461D-4B78-9A54-8124222F6902 Compliance Inspection Report Permit:WQCS00270 Effective: 08/03/22 Expiration: Owner: Town of Smithfield SOC: Effective: Expiration: Facility: Smithfield Collection System County: Johnston Region: Raleigh Contact Person:Walter Credle Title: Public Utility Director Phone: 919-934-2116 Directions to Facility: System Classifications: CS2, Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: NC0030716 Johnston County Public Utilities-Central Johnston County WWTP Inspection Date: 08/26/2024 Entry Time 09:30AM Exit Time: 12:30PM DOCUSiyned by: Primary Inspector:Step CeD Smitf9/4/2024 Phone: 919-791-4200 Secondary Inspector(s) 9Ec679823B1D478.. Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions General Sewer& FOG Ordinances Capital Improvement Plan Map Reporting Requirements Inspections Spill Response Plan Spills Lines Pump Stations (See attachment summary) Page 1 of 6 Docusign Envelope ID:06107E31-461D-4B78-9A54-8124222F6902 Permit: WQCS00270 Owner-Facility:Town of Smithfield Inspection Date: 08/26/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: Page 2 of 6 Docusign Envelope ID:06107E31-461D-4B78-9A54-8124222F6902 Permit: WQCS00270 Owner-Facility:Town of Smithfield Inspection Date: 08/26/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine General Yes No NA NE Is there a properly designated primary ORC and at least one back-up of proper grade? 0 ❑ ❑ ❑ Are logs being reviewed by the system management or owner on a regular basis? 0 ❑ ❑ ❑ #What is that frequency? #Are there any issues being addressed currently or any in the planning stages? ❑ ❑ ❑ Is there a specific pump failure plan available for all pump stations? ❑ ❑ ❑ Does plan indicate if pump parts/new pumps are in spare parts/equipment inventory? ❑ ❑ ❑ Are new/significantly upgraded pump stations equipped with anti-corrosion materials? ❑ ❑ ❑ Does the permittee have a copy of their permit? ❑ ❑ ❑ # Is permit expiring within the next 6 months? ❑ ❑ ❑ If Yes, has the Permittee applied for renewal? ❑ ❑ 0 ❑ Comment: Pumpstation failure plans need to be updated such that they are available at each repsective PS.- This issue is addressed in inspection letter. Sewer and FOG Ordinances Yes No NA NE Is Sewer Use Ordinance(SUO)or other Legal Authority available? ❑ ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? 0 ❑ ❑ ❑ Is there a Grease Control Program that legally requires grease control devices? 0 ❑ ❑ ❑ What is the standard grease trap cleaning requirement in the FOG ordinance? Is Grease Control Program enforced via periodic inspections/records review? 0 ❑ ❑ ❑ Is action taken against violators? 0 ❑ ❑ ❑ #Have satellite systems adopted an equivalent or more stringent ordinance? ❑ ❑ ❑ Is grease/sewer education program documented with req'd customer distribution? 0 ❑ ❑ ❑ #Are other types of education tools used like websites, booths, special meetings, etc? ❑ ❑ ❑ If Yes,what are they?(This can reduce mailing to annual.) Comment: Capital Improvement Plan Yes No NA NE Has a Capital (CIP)or System Improvement Plan been developed and adopted? 0 ❑ ❑ ❑ Is it designated for wastewater only or does it have a dedicated section? 0 ❑ ❑ ❑ Does CIP cover three to five year period of earmarked improvements? ❑ ❑ ❑ Does CIP include description of project area? ❑ ❑ ❑ Does CIP include description of existing facilities? ❑ ❑ ❑ Does CIP include known deficiencies? ❑ ❑ ❑ Does CIP include forecasted future needs? ❑ ❑ ❑ Comment: Map Yes No NA NE Page 3 of 6 Docusign Envelope ID:06107E31-461D-4B78-9A54-8124222F6902 Permit: WQCS00270 Owner-Facility:Town of Smithfield Inspection Date: 08/26/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Is there a overall sewer system map? ❑ ❑ ❑ ❑ Does the map include: Pipe Type(GS/FM) 0 ❑ ❑ ❑ Pipe sizes 0 ❑ ❑ ❑ Pipe materials(PVC, DIP, etc) ❑ 0 ❑ ❑ Pipe location 0 ❑ ❑ ❑ Flow direction 0 ❑ ❑ ❑ Approximate pipe age ❑ 0 ❑ ❑ Pump station ID, location and capacity 0 ❑ ❑ ❑ # Force main air release valve location &type ❑ 0 ❑ ❑ # Location of satellite connections ❑ ❑ 0 ❑ Is the map being updated for changes/additions within 1 year of activation? 0 ❑ ❑ ❑ Comment: The GIS map for the collection system depicts pipe type (FM, GS), location, size, flow direction, pumpstation location, and PS name. Reporting Requirements Yes No NA NE #Have there been any sewer spills in the past 3 years? ❑ ❑ ❑ If Yes,were they reported to the Division if meeting the reportable criteria? ❑ ❑ ❑ If applicable, is there documentation of press releases and public notices issued? ❑ ❑ ❑ Is an Annual Wastewater Performance Report being filed with the Division, if required? ❑ ❑ ❑ Is the report being made available to all its sewer customers? ❑ ❑ ❑ #How is it being made available? Town's website and at Town Hall Comment: Inspections Yes No NA NE Are adequate maintenance records maintained? ❑ ❑ ❑ Are pump stations being inspected at the required frequency? ❑ ❑ ❑ # Is at least one complete functionality test conducted weekly per pump station? ❑ ❑ ❑ Is there a system or plan in place to observe the entire system annually? ❑ ❑ ❑ Is the annual inspection documented? ❑ ❑ ❑ #Does the system have any high-priority lines/locations? ❑ ❑ ❑ Are inspections of HPL documented at least every 6 months? ❑ ❑ ❑ Are new lines being added to the HPL list when found or created? 0 ❑ ❑ ❑ Comment: Inspection revealed that back up power is tested monthly. Spill Response Action Plan Yes No NA NE Is a Spill Response Action Plan available? 0 ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? 0 ❑ ❑ ❑ Page 4 of 6 Docusign Envelope ID:06107E31-461D-4B78-9A54-8124222F6902 Permit: WQCS00270 Owner-Facility:Town of Smithfield Inspection Date: 08/26/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine Does the plan include: 24-hour contact numbers ❑ ❑ ❑ Response time ❑ ❑ ❑ Equipment list and spare parts inventory ❑ ❑ ❑ Access to cleaning equipment ❑ ❑ ❑ Access to construction crews, contractors, and/or engineers ❑ ❑ ❑ Source of emergency funds ❑ ❑ ❑ Site sanitation and cleanup materials ❑ ❑ ❑ Post-overflow/spill assessment ❑ ❑ ❑ Does the Permittee appear to respond within 2 hours of first knowledge of a spill? ❑ ❑ ❑ Comment: aRiL Yes No NA NE Is system free of known points of bypass? ❑ ❑ ❑ If No, describe type of bypass and location Are all spills or sewer related issues/complaints documented? ❑ ❑ ❑ #Are there repeated overflows/problems(2 or more in 12 months)at same location? ❑ ❑ ❑ # If Yes, is there a corrective action plan? ❑ ❑ 0 ❑ Comment: Lines/Right-of-Ways/Aerial Lines Yes No NA NE Please list the Lines/Right of Ways/Aerial Lines Inspected: HPL-Lowes Behind @ railroad; Wilson Mil Road @ Laurel Dr; Elm Dr. in Swamp. Are right-of-ways/easements maintained for full width for access by staff/equipment? ❑ ❑ ❑ If No, give details on temporary access: Is maintenance documented? ❑ ❑ ❑ Are gravity sewer cleaning records available? ❑ ❑ ❑ Has at least 10%of lines older than 5 yrs been cleaned annually? ❑ ❑ ❑ Were all areas/lines inspected free of issues? ❑ 0 ❑ ❑ Comment: One Pillar/support at Elm Drive in Swamp was less than vertical. This item is addressed in letter. Pump Stations Yes No NA NE Please list the Pump Stations Inspected: #Number of duplex or larger pump stations in system 21 #Number of vacuum stations in system 0 #Number of simplex pump stations in system 4 #Number of simplex pump stations in system serving more than one building How many pump/vacuum stations have: Page 5 of 6 Docusign Envelope ID:06107E31-461D-4B78-9A54-8124222F6902 Permit: WQCS00270 Owner-Facility:Town of Smithfield Inspection Date: 08/26/2024 Inspection Type:Collection System Inspect Non Sampling Reason for Visit: Routine # A two-way"auto polling"communication system (SCADA)installed? 21 # A simple one-way telemetry/communication system (auto-dialer)installed? For pump stations inspected: Are they secure with restricted access? 0 ❑ ❑ ❑ Were they free of by-pass structures/pipes? 0 ❑ ❑ ❑ Were wet wells free of excessive grease/debris? 0 ❑ ❑ ❑ # Do they all have telemetry installed? 0 ❑ ❑ ❑ Is the communication system functional? 0 ❑ ❑ ❑ Is a 24-hour notification sign posted ? 0 ❑ ❑ ❑ Does the sign include: Owner Name? 0 ❑ ❑ ❑ Pump station identifier? 0 ❑ ❑ ❑ # Address? 0 ❑ ❑ ❑ Instructions for notification? ❑ ❑ ❑ 24-hour emergency contact numbers? 0 ❑ ❑ ❑ Are audio and visual alarms present? 0 ❑ ❑ ❑ Are audio and visual alarms operable? ❑ 0 ❑ ❑ # Is there a backup generator or bypass pump connected? 0 ❑ ❑ ❑ If tested during inspection, did it function properly? ❑ ❑ ❑ Is the back-up system tested at least bi-annually under normal operating conditions? 0 ❑ ❑ ❑ #Does it have a dedicated connection for a portable generator? ❑ ❑ 0 ❑ # Is the owner relying on portable units in the event of a power outage? ❑ ❑ 0 ❑ # If Yes, is there a distribution plan? ❑ ❑ ❑ If Yes,what resources (Units/Staff/Vehicles/etc)are included in Plan? #Does Permittee have the approved percentage of replacement simplex pumps? ❑ ❑ ❑ Is recordkeeping of pump station inspection and maintenance program adequate? 0 ❑ ❑ ❑ Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? 0 ❑ ❑ ❑ Inspecting and exercising all valves? 0 ❑ ❑ ❑ Inspecting and lubricating pumps and other equipment? 0 ❑ ❑ ❑ Inspecting alarms,telemetry and auxiliary equipment? 0 ❑ ❑ ❑ Comment: Inspection revealed two (2) PS (Wal-Mart and Longview) audible and visual alarms were in needed repair. Wal-Mart had already been scheduled for repair other other was being addresed/scheduled during the inspection. (SCADA operated properly for all PS inspectied, including Wal-Mart and Longvielw stations) Page 6 of 6