HomeMy WebLinkAboutWQ0022870_Compliance Evaluation Inspection_20240627ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
Stephen A. Miller
102 Get A Way Lane
Bahama, NC 27503
NORTH CAROLINA
Environmental Quality
August 30, 2024
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
General NPDES Permit NCG550000
Certificate of coverage NCG550807
Facility: 186 Munday Oakley Road, Semora
Person County
Dear Mr. Miller,
On June 27, 2024, Curtis Tyree from the Raleigh Regional Office visited your single-family
residence (SFR) wastewater treatment system to evaluate compliance with the subject General
NPDES Permit.
Our records indicate the treatment system consists of a septic tank; dual primary sand filters; a
secondary sand filter; a chlorinator and chlorine contact chamber; cascade aeration; and
associated appurtenances with the discharge of treated waste to receiving waters designated as
Hyco Lake in the subbasin of the Roanoke River Basin.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG550807 authorize
the discharge of domestic wastewater from your treatment system to an unnamed tributary
Findings during the inspection were as follows:
1. The septic tank shall be checked annually and pumped out every 3 to 5 years. The home is
a vacation home, and the septic tank is checked annually.
2. Treatment syste►n operation. The treatment system shall be maintained at all tunes to
prevent seepage of sewage to the surface of the ground. At the time of the inspection, the
system appeared to be well maintained.
3. Chlorination. The tablet chlorinator shall be inspected weekly to ensure there is an
adequate supply of tablets for continuous and proper operation. Wastewater grade tablets
(calcium hypochlorite) shall be added as needed to provide proper chlorination
(swimming pool chlorine tablets _shall not be used). At the time of the inspection, the
inspector observed tablets in the chlorinator.
ANorth Carolina Ikpartaiant of l-nvironinental Quality I Division of Water Resources
1jiD E Q:> Raleigh Regional Office! 3800 Barren lhive I Raleigh. North Carolina 27609
" °�— V 91V 791.4200
Stephen Miller- NCG550807
August 30, 2024
Page 2
4. Outfall location, A visual review of the outfall location shall be executed twice each year
(one at the time of sampling) to ensure that no visible solids or other obvious evidence of
system malfunctioning is observed. Any visible signs of a malfunctioning system shall be
documented, and steps taken to correct the problem. At the time of the inspection, the
outfall location was clear and appeared to be well maintained and free of any obstructions.
There was no water discharging at the time of the inspection.
5. Effluent sampling requirements. Effluent sampling must be conducted annually as part
of your permit requirements. The effluent samples must be analyzed by a North Caroline
Certified Lab and the results must be kept on site for three years The effluent sample
results from May 22, 2024, were within the permit limits.
6. Fees and renewals COC's with unpaid administering and compliance monitoring fees
will not be automatically renewed. The fees must be paid annually and within 30 days of
notification. All fees have been paid.
If you have questions or comments about this inspection or the requirements of your permit,
please contact Curtis Tyree via email at curtis.tvreeawde .ng c. ov or 919-791-4251.
Sincerely,
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment: EPA Water Compliance Inspection Report
Cc: Laserfiche
D_E Q North Carolina Depbury Snrcnt of 611 Environmental Quality IDivisionag Water Resources27
512 Nonh Salisbury SIreG 1 1G11 Mail Senice C¢ntt'r I Raleigh. Noah Carolina 27699-1611
919707.9000
GepYbnnlaf rmh0min W OmW,
United States Environmental Protection Agency Form Approved.
EPA Washington, D.C. 20460 OMB No. 2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES
yrlmolday
Inspection Type
Inspector Fac Type
1 E 2 15 1 3 I NCG550807 111 121
24/06/27
117 181 C I
19 I S I 201 I
211E 1 1 1 1 _Ll_[_l I I I I I I III I I
I I I I
I Ll I I I I I I. I
I I I I I I I Ifi6
Inspection Work Days Facility Self -Monitoring Evaluation Rating
B1
QA
Reserved--------
671
1 701 1
71 I I
72 L N 1 73I I I74
71 1 1 1 1 1 1
180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry TimelDate Permit Effective Date
POTW name and NPDES oermit Number) 08:35AM 24/06/27 21/08/24
186 Munday Oakley Rd
186 Munday Oakley Rd
Semora NC 27343
Name(s) of Onsite Representative(s)ffitles(s)lPhone and Fax Number(s)
111
Name, Address of Responsible Of(iciallTitlelPhone and Fax Number
Contacted
Stephen Alfred Miller,17 Fairwoods Dr Durham NC 27712/1919-560-43441
No
Exit Time/Date Permit Expiration Date
08:50AM 24/06/27 25/10/31
Other Facility Data
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Operations & Maintenai Records/Reports Sludge Handling Dispo: E Facility Site Review
Effluent/Receiving Wate Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Curtis Tyree DWRlRRO WQ1919-791 42391
-------------
Signature of Ma gemenl Q A Reviewer Agency/Office/Phone and Fax Numbers Date
3q Z;:, 7-
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPOES yrlmolday Inspection Type
NCG550807 �11 12 24106;27 117 18 ICI
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
The home is empty and for sale.
The system appears to be well maintained.
Effluent was sampled as part of the sale and meets permit requirements
Page#
Permit: NCG550807 Owner -Facility: 186 Munday Oakley Rd
Inspection Date: 06/27/2024 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:: The system appears to be well maintained
Septic Tank
Yes No
NA
NE
(If pumps are used) Is an audible and visual alarm operational?
❑
❑
❑
Is septic tank pumped on a schedule?
❑
❑
❑
Are pumps or syphons operating properly?
❑
❑
❑
Are high and low water alarms operating properly?
❑
❑
M
❑
Comment: This is a vacation home that is used about 2 or three weeks each vear and there are
very little solids in the septic tank
Disinfection -Tablet Yes No NA NE
Are tablet chlorinators operational? M ❑ ❑ ❑
Are the tablets the proper size and type? 0 ❑ ❑ ❑
Number of tubes in use? 2
Is the level of chlorine residual acceptable? ❑ ❑ ❑ 0
Is the contact chamber free of growth, or sludge buildup? ❑ ❑ ❑
Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑
Comment:
Page# 3