Loading...
HomeMy WebLinkAboutNCG551321_Inspection_20240826 August 26, 2024 Peter A. Leone 107 Turnage Road Chapel Hill, NC 27597-6125 Subject: Compliance Evaluation Inspection Single Family Wastewater Treatment System General NPDES Permit NCG550000 Certificate of Coverage NCG551321 Facility: 107 Turnage Road, Chapel Hill, NC 27517 Orange County Dear Mr. Leone: On August 14, 2024, Tyler Clark from the Raleigh Regional Office visited your single-family residence (SFR) wastewater treatment system to evaluate compliance with the subject General NPDES Permit. Your assistance during the inspection was greatly appreciated. Our records indicate the treatment system consists of a septic tank, one AX-20 pretreatment unit, a 1000- gallon recirculating tank w/ UV disinfection, and a discharge pipe with a cascade aerator. General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG551321 authorize the discharge of domestic wastewater from your treatment system to receiving waters designated as unnamed tributary to Buck Branch (classified WS-IV, NSW) in the Cape Fear River Basin. The authorized discharge is in accordance with the effluent limits and monitoring requirements established within the General Permit. The items below show what conditions were noted at your facility: Findings during the inspection were as follows: 1. Treatment system operation: The wastewater treatment system shall be maintained at all times to prevent seepage of sewage to the surface of the ground. 2. Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. Within 30 days of receiving this letter, please send a copy of the most recent receipt/invoice to this office showing the date the septic tank was last checked and/or pumped out. The General NPDES Permit requires the permittee to retain records associated with sewage disposal activities for a period of at least 5 years. Docusign Envelope ID: DE5D5340-65FF-4B7D-90E0-0551C9222FB7 Peter Leone, NCG551321 August 26, 2024 Page 2 of 3 3. UV Disinfection: Your system uses an ultra-violet (UV) light system for disinfection of the discharged wastewater. New rules put into place on August 1, 2007 require all SFR systems to have a means of disinfection (and dechlorination when chlorine tablets are used to disinfect, if the system was installed since that date). A UV disinfection system provides effective disinfection and prevents/limits harmful bacteria from discharging to the environment. Unless the UV disinfection unit is monitored by telemetry, the unit shall be checked weekly. The lamp(s) and quartz sleeve(s) shall be cleaned or replaced as needed to ensure proper disinfection of the discharged wastewater. Within 30 days of receiving this letter, please provide proof that the UV light is functioning properly to ensure proper disinfection of the discharged wastewater. 4. Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total Phosphorous. Within 30-days of receiving this letter, please let this office know if you have monitored your effluent discharge within the last 12 months and provide this office with a copy of the lab results if you have. If you have not monitored your effluent, then please collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory and submit the results to this office no later than September 30, 2024. If, during this time, you are unable to collect a representative sample of the effluent discharge due to insufficient flow from the discharge pipe, then update this office with that information and continue to monitor the discharge and if conditions for sampling become favorable, then arrange to collect a sample. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. 5. Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented and steps taken to correct the problem. The discharge pipe was visible and accessible the day of the inspection. Please continue to ensure the outlet is always visible/maintained and cleared of vegetation, soil and leaves. Part II Section B.14 of General Permit NCG550000 requires the permittee to “pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division.” The annual fee ($60 per year) for the period February 1, 2024 through January 31, 2025, was due by February 3, 2024. This fee has not been paid and is overdue. In addition, there are three unpaid invoices from previous years (see attached invoices). Payment in the amount of $240 must be remitted to the Division as indicated on the attached Annual Permit Fee Invoices. The wastewater treatment system should be periodically inspected to ensure the treatment components are always maintained and in good operating order. You are also reminded to maintain all monitoring data and associated maintenance records onsite for a minimum of three years and available for inspection. Docusign Envelope ID: DE5D5340-65FF-4B7D-90E0-0551C9222FB7 Peter Leone, NCG551321 August 26, 2024 Page 3 of 3 Within 30 days receipt of this letter, please submit a written response to this office indicating the actions you will take or have taken to comply with or resolve the issues noted items #2-#4 above. If you have questions or comments about this inspection or the requirements to take corrective action (if applicable), then please contact Tyler Clark at 919-791-4242. Sincerely, Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachment(s): EPA Water Compliance Inspection Report Annual Permit Fee Invoice – Due Feb. 3, 2024 Annual Permit Fee Invoice – Due Feb. 5, 2021 Annual Permit Fee Invoice – Due Feb. 9, 2020 Annual Permit Fee Invoice – Due Feb. 5, 2018 Cc: RRO/SWP Files Laserfiche Docusign Envelope ID: DE5D5340-65FF-4B7D-90E0-0551C9222FB7 EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NCG551321 24/08/14 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 107 Turnage Road 107 Turnage Rd Chapel Hill NC 27514 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 01:00PM 24/08/14 13/08/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 01:45PM 24/08/14 18/07/31 Name, Address of Responsible Official/Title/Phone and Fax Number Peter A Leone,107 Turnage Rd Chapel Hill NC 27514//919-843-0724/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Records/Reports Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Timothy Clark DWR/RRO WQ/919-791-4234/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 8/20/2024 Docusign Envelope ID: F292FF23-7501-4482-B687-991BD6CA6A16 8/27/2024 NPDES yr/mo/day 24/08/14 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Findings during the inspection were as follows: 1.Treatment system operation: The wastewater treatment system shall be maintained at all times to prevent seepage of sewage to the surface of the ground. 2.Pumping the septic tank: You are required to inspect the septic tank at least yearly to determine if solids must be removed or if other maintenance is necessary. Septic tanks should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping company can check the status periodically and determine when pumping is required. Within 30 days of receiving this letter, please send a copy of the most recent receipt/invoice to this office showing the date the septic tank was last checked and/or pumped out. The General NPDES Permit requires the permittee to retain records associated with sewage disposal activities for a period of at least 5 years. 3.UV Disinfection: Your system uses an ultra-violet (UV) light system for disinfection of the discharged wastewater. New rules put into place on August 1, 2007 require all SFR systems to have a means of disinfection (and dechlorination when chlorine tablets are used to disinfect, if the system was installed since that date). A UV disinfection system provides effective disinfection and prevents/limits harmful bacteria from discharging to the environment. Unless the UV disinfection unit is monitored by telemetry, the unit shall be checked weekly. The lamp(s) and quartz sleeve(s) shall be cleaned or replaced as needed to ensure proper disinfection of the discharged wastewater. Once the residence is occupied and wastewater is being generated, please ensure the UV disinfection unit is properly operated and maintained to ensure optimal performance. Within 30 days of receiving this letter, please provide proof that the UV light is functioning properly to ensure proper disinfection of the discharged wastewater. 4.Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements, within General Permit NCG550000 requires a permittee to sample and analyze the effluent leaving his/her treatment system prior to discharge annually. Parameters to be sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total Suspended Solids, Fecal Coliform, Total Residual Chlorine, Total Nitrogen, Ammonia Nitrogen and Total Phosphorous. Within 30-days of receiving this letter, please let this office know if you have monitored your effluent discharge within the last 12 months and provide this office with a copy of the lab results if you have. If you have not monitored your effluent, then please collect a representative sample of the effluent, have it analyzed by a certified commercial laboratory and submit the results to this office no later than September 30, 2024. If, during this time, you are unable to collect a representative sample of the effluent discharge due to insufficient flow from the discharge pipe, then update this office with that information and continue to monitor the discharge and if conditions for sampling become favorable, then arrange to collect a sample. Failure to monitor the effluent discharge as required is a violation of NPDES General Permit NCG550000. 5.Discharge outlet location. The permittee is required to conduct a visual review of the outfall location at least twice each year (one at the time of sampling) to ensure that no visible solids or other obvious evidence of system malfunctioning is observed. Any visible signs of a malfunctioning system shall be documented and steps taken to correct the problem. The discharge pipe was visible and accessible the day of the inspection. Please continue to ensure the outlet is always visible/maintained and cleared of vegetation, soil and leaves. Part II Section B.14 of General Permit NCG550000 requires the permittee to “pay the annual administering and compliance monitoring fee within thirty days after being billed by the Division.” The annual fee ($60 per year) for the period February 1, 2024 through January 31, 2025, was due by February 3, 2024. This fee has not been paid and is overdue. Payment in the amount of $60 must be remitted to the Division as indicated on the attached Annual Permit Fee Invoice. NCG551321 17 (Cont.) Page#2 Docusign Envelope ID: F292FF23-7501-4482-B687-991BD6CA6A16 Permit:NCG551321 Inspection Date:08/14/2024 Owner - Facility: Inspection Type: 107 Turnage Road Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Page#3 Docusign Envelope ID: F292FF23-7501-4482-B687-991BD6CA6A16 NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY This annual fee is required by the North Carolina Administrative Code. It covers the administrative costs associated with your permit. It is required of any person holding a permit for any time during the annual fee period, regardless of the facility’s operating status. Failure to pay the fee by the due date will subject the permit to revocation. Operating without a valid permit is a violation and is subject to a $10,000 per day fine. If the permit is revoked and you later decide a permit is needed, you must reapply, with the understanding the permit request may be denied due to changes in environmental, regulatory, or modeling conditions. INVOICE Annual Permit Fee Overdue *2024PR000576* Permit Number:NCG551321 Annual Fee Period: Orange County Invoice Date:01/04/2024 107 Turnage Road Due Date:02/03/2024 Annual Fee:$60.00 02/01/2024 to 01/31/2025 Peter A. Leone 107 Turnage Rd Chapel Hill, NC 27514 2024PR000576Invoice Number: Notes: 1.You may pay either by mail with check/money order OR by electronic payment (eCheck or Credit Card). 2.If payment is by check/money order, please remit payment to: NCDEQ - Division of Water Resources Attn: Animal/Discharge/Non-Discharge Billing 1617 Mail Service Center Raleigh, NC 27699-1617 3.If payment is electronic, please see https://epay.deq.nc.gov/wq-epayments.html to pay electronically. Payments by eCheck will debit your checking account. Credit card transactions will incur a convenience fee. 4.Please include your Permit Number and Invoice Number on all correspondence. 5.A $35.00 processing fee will be charged for returned checks in accordance with North Carolina General Statute 25-3-506. 6.The Department cannot accept checks older than 6 months under Uniform Commercial Code 4-404. 7.Non-Payment of this fee by the payment due date will initiate the permit revocation process. 8.Should you need to update any Owner/Permit/Contact information or have any questions regarding this invoice, please send email to dwqepay@deq.nc.gov or you may also contact the following: - NPDES WW Program Administrative Contact at 919-707-3601 or - Annual Administering and Compliance Fee Coordinator at 919-707-3698 Peter A. Leone 107 Turnage Rd Chapel Hill, NC 27514 Invoice Number: (Return This Portion With Check) ANNUAL PERMIT INVOICE Permit Number:NCG551321 Annual Fee Period: Orange County Invoice Date:1/4/2024 107 Turnage Road Due Date:2/3/2024 Annual Fee:$60.00 Check Number: 02/01/2024 to 01/31/2025 Overdue *2024PR000576* 2024PR000576