Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0045745_City_of_Randleman_Earnhardt_Apartments_FTSSE_Permit_Application_1st_Submission_20240815
State of North Carolina N C D rar.�ment of Department of Environmental Quality Environmental Quality Division of Water Resources Receive FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources AUG 15 2024 FTA 10-23 & SUPPORTING DOCUMENTATION Winston-Salem C/�'r t { App*tibow,�ftr: ; Jd 0 4 ,J 7�✓ (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Randleman (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County Municipal 3. Signature authority's name: Shain Sexton per 15A NCAC 02T .0106(b) Title: Iterim City Manager / 4. Applicant's mailing address: 204 S. Main Street ell z City: Randleman State: NC Zip: 27317- 5. Applicant's contact information: Phone number: (336) 495-7500 Email Address: ssexton@randlemanpolice.or II. PROJECT INFORMATION: 1. I Project name: City of Randleman Earnhardt Apartments Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project ❑ Privately -Owned Public Utility ❑ Other If a modification, provide the existing permit number: WQ00 and issued date: , ❑ ARPA funded For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Randolph 11 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.805°Longitude: -79.817' 5. Parcel ID (if applicable) III. CONSULTANT INFORMATION: (or Parcel ID to closest downstream sewer) Professional Engineer: Hiram J. Marziano License Number: 7707 Firm: Hiram J. Marziano, P.E. Mailing address: P. O. Box 278 City: Asheboro State: N6 Zip: 2720440 78 Phone number: (336) 953-6186/ Email Address: hmarzianona,triadbiz.rr.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Randleman WWTP� Permit Number: NCO025445 Owner Name: City of Randleman V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ0004825 2. Downstream (Receiving) Sewer Information: 8 inch / © Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00099 / Owner Name(s): City of Randleman / FORM: FTA 10-23 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® N/A f 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement FORM: DEV) been attached? ❑ Yes ❑ No ® N/A,' 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? [:]Yes ❑ No ® N/A / 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ® Residential (Leased) / ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .01 14(f)? ❑ Yes ❑ No ➢ If Yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a b No. of Units Fjpw 72 Apartments w/2 & 3 bedrooms 75 gal/day/bedroom 168 12,600 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 12,4 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e. proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 12,600 GPD (per 15A NCAC 02T .0114 and G.S. 143-215.1) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 10-23 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 ./ 1062 / PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0Longitude: - ° 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01 C. Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(13)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 10-23 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): / 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T.0305(f) & (g)? ® Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 2Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 2Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(f) or W, see Section X.1 of this application * 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpae 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes [:]No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. i 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ®No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes Z No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six-montbs and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 10-23 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (.latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes, ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and proiects requiring a variance approval may be subiect to longer review times. For proiects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the proiect, the full technical review is required. 2. Professional Engineer's Certification: 1, []� '-S 4( -t `(M" • Zicm u , attest that this application for v h �; og ,.4--e4l-� (Professional Engineer's name from Application Item III.1.) (Project Name om A' pplic+on em I .1 has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) ...................................................................................... �i111/ North Carolina Professional Engineer's seal, signature, and date: �'t�►14 L M fool 3. Applicant's Certification per 15A NCAC 02T .0106(b): i I, 4 G-I r, attest that this application for Ec�r C1\N('11r &A (Signature Authority Name from Application Item I.3.) (Project Name from Application Item II.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. i s Signature: 4, IJ Date: FORM: FTA 10-23 Page 5 of 5 D R � W� Divislon of State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-23) Entity Requesting Allocation: City of Randleman "` Project Name for which flow is being requested: Earnhardt Apartments) More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Randleman WWTP" b. WWTP Facility Permit #: NCO025445 -' c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 1.745 0 0.7473 ' 0.0126 ' 0.7599 43.55 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station Firm (Name or Permit Capacity, Number) No. MGD Main WQSC00099 5.143 (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Average Approx. Obligated, Total Daily Current Not Yet Current Flow Flow** Avg. Daily Tributary Plus (Firm / pf), Flow, Daily Flow, Obligated Available MGD MGD MGD Flow Capacity*** 2.057� 0.7473/ 0.0126 0.7�99 1.297 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pt) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Deep River Outfall Page 1 of 7 FTSE 1.0-23 III. Certification Statement: f Brian Crawford certify to the best of my knowledge that the addition of / the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any `capacity'related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Official Signature Title of Signing Official ❑PLANNING ASSESSMENT ADDENDUM (PAA) NC Department of Environmental Quality Received 08.8.2024 i AUG 15 2024 Winston-Salem To Regional Office NCDEQ-WS Enclosed, please find the following items relative to a Fast Track Application for EARNHART APARTMENTS, in Randleman, Randolph Co., N.C. for your review and/or approval.: From Hiram J. Marziano, PE 1. Cover Letter/Project Narrative -(Original + 1 Copy). 2. Check in the amount $600.00 to cover the permit fee cc 3. Fast Track Application, Form: FTA 10-23-(Original + 1 Copy). Bobby Earnhardt, Brian Crawford 4. Flow Tracking/Acceptance Form-FTSE 10-23-(Original + 1 Copy) 5. Color 8.5"x11" USGS Topographic Map w/annotations of the Project Re 6. Aerial Location Map w/coordinates & sewer line ties. FTA Appl. For Earnhardt Apartments, Randleman, 7. Street view map from Google Earth of the site location. Randolph Co. N.C. Project Description/Narrative This project proposes to ultimately construct six (6) apartment buildings having twelve (12) apartments each for a total of 72, 2 & 3 bedroom units. The project site is in the corporate limits of the City of Randleman. Water/Sewer/Fire & Police protection, and Solid Waste disposal will be provided by the city. The project is zoned properly, and the site plan was approved by the city. The project does not contain any wetlands or lie in a protected watershed. In addition to this fast track sewer application, applications for water, driveway access and erosion control are being submitted. Regarding the sewer service, on -site gravity wastewater lines will be constructed to tie directly into the existing sewer line located on the adjacent Stout Street. The receiving sewer line flows entirely by gravity until it is intercepted by the city's main lift station at the WWTF. All wastewater generated from this project will be domestic. If you need additional information, please advise. Thank you for your review. Signed: • ♦ � yr: _ � � M&.LCTm - , -,% ENGINEER Tel: 336-493-4450 PO Box 278 � HIRAM J. Cell: 336-953-6186 Asheboro. N.C. 27204 hmarziana tricadbiz.rr.com . AR2IANQ,_PE', Randolph County, NC REID PIN TAXED ACREAGE PROPERTY DESCRIPTION DEED BOOK & PAGE PLAT BOOK & PAGE OWNER OWNER ADDRESS 47084 7755704146 6 R1955;W 002776/01420 RANDOLPH BUILDING SUPPLY LLC PO BOX 58 OWNER ADDRESS2 OWNER CITY OWNER STATE OWNER ZIP LOCATION ADDRESS LOCATION ZIP DATA REFRESHED RANDLEMAN NC 27317 No Physical Address No ZIP 12/10/2023 Disclaimer- This map was compiled from recorded deeds, plats, and other public records and data. Map Scale (a Users of this data are hereby notified that the aforementioned public information sources should be 1 inch = 400 feet ?r ' consulted for verification of the information. Randolph County, its agents and employees make no 12/12/2023 warranty as to the accuracy of the information on this map. EARNHARDT APARTMENT SITE RANDLEMAN-RANDLOPH CO. list' f ` r y • r B3. - Aedal Location Map EARNHARDTAPARTMENTS Randleman,of No Scale • •