Loading...
HomeMy WebLinkAboutWQ0045700_Wilkes_County_Rural_Community_Wastewater_Extension_FTSSE_Permit_Application_Final_Submission_20240815DWR, Division of Water Resources EnvirU Received e; li:ai ��State of North Carolina e 1'024 Department of Environmental Quality AUG I LDivision of Water Resources Winston-Salem FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Regional FTA 10-23 &SUPPORTING DOCUMENTATION Grfice Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: North Wilkesboro (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Holly Minton per 15A NCAC 02T .0106(b) Title: Town Manager 4. Applicant's mailing address: P.O. Box 218 City: North Wilkesboro State: NC Zip: 28659- 5. Applicant's contact information: Phone number: (336) 667-7129 Email Address: townmanagerknorthwilkesboronc.gov II. PROJECT INFORMATION: 1. Project name: Wilkes County Rural Community Wastewater Extension 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Wilkes 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.14366' Longitude:-81.0899' 5. Parcel ID (if applicable): 2200990 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Ryan Hager,_ PE License Number: 031444 Firm: W.K.Dickson & Co., Inc. Mailing address: 401 4`h Street, SW City: Hickory State: NC Zip: 28602- Phone number: (828) 327-6911 Email Address: rwhagergwkdickson.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Thurman Street Wastewater Treatment Plant Permit Number: NCO020761 Owner Name: North Wilkesboro V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ Unknown 2. Downstream (Receiving) Sewer Information: 8 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00093 Owner Name(s): Town of North Wilkesboro FORM: FTA 10-23 Page I of 5 L11 V;.-O Z1: 1 _'.:rl::.ii L IL Received VI. GENERAL REQUIREMENTS AUG 13 2 012 h 1. If the Applicant is a Privately -Owned Public Utili , has,a Ce�tific� of Public Convenience and Necessity been attached? �IVinsion,-Jett PQbsn P t C0 N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ® Other (Explain in Attachment) 5. Nature of wastewater: % Domestic 100 % Commercial % Industrial (See 15A NCAC 02T .0103(201) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ®No ➢ If Yes, provide a cony of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow Stadium 5 gal/seat 20,000 100,000 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 100,000 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(22) for caveats to wastewater design flow rates (i.e. proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 100,000 GPD (per 15A NCAC 02T .0114 and G.S. 143-215.1) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 10-23 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 4,135 PVC 8 670 DIP 41 VL"r�°7s� Rega%em �ona1 Gffioe ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Puma Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED M THIS PROJECT 1. Pump station number or name: Fishing Creek Pump Station 2. Approximate Coordinates (Decimal Degrees): Latitude: 36.14366' Longitude:-81.0899' 3. Total number of pumps at the pump station: 2 3. Design flow of the pump station: 0.3024 millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): 210 gallons per minute (GPM) at 122 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6 3,725 PVC 6 385 DIP If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.l.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 10-23 Page 3 of 5 {4 C DC p r .m,cn', o Environmenial Quality Received IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): AUG 13 2024 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(fA&•( Won_SaA Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be Provided forRcwtr nsw,stgMW.4. rA Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches ZWater mains (vertical - water over sewer preferred, including in benched trenches) 18 inches ZWater mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application *15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. "Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 213.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 10-23 Page 4 of 5 DWR Division of Water Resources NC Department of State of North Carolina Environmental Quality Department of Environmental Quality Received p Q tY Division of Water Resources k 2 2 ST TRACK SEWER SYSTEM EXTENSION APPLICATION Winston-SalemFTA 10-23 & SUPPORTING DOCUMENTATION Regiona Application Number: J4 ce (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: i I . Applicant's name: North Wilkesboro (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Holly Minton per 15A NCAC 02T .0106(b) Title: Town Manager 4. Applicant's mailing address: P.O. Box 218 City: North Wilkesboro / State: NC Zip: 28659- 5. Applicant's contact information: Phone number: 336) 667-7129 / Email Address: townmanager@northwilkesboronc.gov 11. PROJECT INFORMATION: ❑ Privately -Owned Public Utility ❑ Other 1. Project name: Wilkes County Rural Community Wastewater Extension 2. Application/Project status: ®Proposed (New Permit) ❑ Existing Pennit/Project If a modification, provide the existing permit number: WQ00 and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00_ 3. County where project is located: Wilkes ' 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.143660 Longitude:-81.0899' 5. Parcel ID (if applicable): 2200990 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Ryan Hager, PEA License Number: 031444 Firm: W.K.Dickson & Co., Inc.,, Mailing address: 401 4th Street, SW / City: Hickory ' State: NC Phone number: 828) 327-6911 O Zip: 28602- Email Address: rwhager@wkdickson.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Thurman Street Wastewater Treatment Plant Permit Number: NCO020761 Owner Name: North Wilkesboro. V. RECEIVING DOWNSTREAM SEWE INFO) MATION: 1. Permit Numbe Cs)-WQCS00093 2. Downstream (Receiving) Sewer Information: 8 inch ❑x Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00093 Owner Name(s): Town of North Wilkesboro FORM: FTA 10-23 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ® N/A - 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0I 15(c) been attached? ❑ Yes ❑ No ® N/A - 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ® Other (Explain in Attachment)' 5. Nature of wastewater: % Domestic 100 % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(1)? ❑ Yes ®No' ➢ If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) F Daily Design Flow a°b No. of Units Flow Stadium 5 gal/seat 20,000 100,000 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 100,000 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e. proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 100,000 GPD (per 15A NCAC 02T .0114 and G.S. 143-215.1) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 10-23 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 4,135- PVC 8 ` 670 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Fishing Creek Pump Station 2. Approximate Coordinates (Decimal Degrees): Latitude: 36.14366' Longitude:-81.0899' 3. Total number of pumps at the pump station: 2 3. Design flow of the pump station: 0.1 millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): 210 gallons per minute (GPM) at 122 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6 3,725 PVC 6 385 DIP If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.l.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 10-23 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T.0305(f) & (g)? ® Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 2Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 2Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application *15A NCAC 02T.0305(Q) contains alternatives where separations in 02T.0305(fl cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpaee 2. Does this project comply with the minimum separation requirements for water mains? ® Yves [-]No ❑ N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® �es [—]No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ❑ Yes Basin name: ® No, If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. r 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 10-23 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes � ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical review is required. Professional Engineer's Certification: I, y�l✓� /k5 e ✓ , attest that this application for (Profe sional Engineer's name from Application Item III.1.) WtLK155 C.o4wrY 0KAL CNA W✓;VT W1.,/ C,<-j (Project Name from Application Item II.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: Applicant's Certification per 15A NCAC AN (02T.0106(b): I, Alt t 6�}`-- attest that this application for WZLK �S (Signature Au ority Name from Application Item I.3.) (Project Name from Application Item II.1) GouuT'/ INCAL GOMnoWZTY WV1 6XT, attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exce d $10,000 as well as civil penalties up to $25,000 per violation. i Signature: Date: M 6?Z62 FORM: FTA 10-23 Page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-23) Entity Requesting Allocation: North Wilkesboro Project Name for which flow is being requested: Wilkes County Rural Comm WW Ext More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Thurman Street Wastewater Treatment Plant b. WWTP Facility Permit #: NCO020761 ' c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 2.0-� 0% 1.1 ' 0.1 - 1.2 ' 60% I1. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Speedway 0.216 0.086 0.045 0.1 0.145� -0.059 VFW 0.576 0.23 0.072 ( 0.1 0.172 0.058( * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Thurman Street WWTP Downstream Permit Number: NCO020761 Page 1 of 6 FTSE 10-23 III. Certification Statement: AA1)1-- I certify to the best of my knowledge that the addition of the volu e f wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. ial Date Page 2 of 6 FTSE 10-23 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 170 % and -0.059 MGD of the Available Capacity (E) in Pump Station Speedway ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.1 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely NCDOT Hwy 115 Widening (R-5759) is in design or under construction with planned completion in late 2026 ; and/or d. The following applies: An upgrade of the Speedway Rd pump station is currently under design as part of NCDOT's project R-5759. The Speedway Rd pump station upgrade will increase the firm capacity of the pump station to 0.504 MGD (350 gpm), and 0.202 MGD design average daily flow, will be constructed concurrently with the time in which the proposed project begins to receive wastewater flow. Thus providing an available capcity of 0.057 MGD at the Speedway Pump Station, after the proposed project and the R-5759 project are complete, insuring that the required downstream capacity will be available. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143- 215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. 26 Date Page 3 of 6 FTSE 10-23 0 F-I ,4 O moo 0 ;; 1� 1, ..Cr mm cp CL- 49 LL 0 LL CL to 00 .00 00 Cp T V) U 0 Z M, Nz E vv CL CL cn C� Ln ui X en M 0. CL 40 E 0. N r_— r-1 x Ri CL O CD r� .Ro I, r —31 0 U. —J 6. 00 CUP fi > CL IL RAILS a. U. ON ",,,f IN LL c d) m �j 0 L-I > Le) t 2 Q) RL i LL ch : CL 0- r�- ��STATESVTJLE RD U.L N s j j� A .. siEFaverra L. cc 0 Aj —Sleepy -G-L:—& lft�wl< DICI<SOICI community Infrastructure consultants August 7, 2024 NCDEQ Division of Water Resources Winston-Salem Regional Office 450 West Hanes Mill Rd, Suite 300 Winston-Salem, NC 27105 RE: Wilkes County Rural Community Wastewater Extension FTA 10-23 Fast Track Application for Approval North Wilkesboro, North Carolina WK Dickson # 20220842.00.CL NC Department of Environmental Quai . 4,1 Received AU6 , n Winston-Salem Regional office Enclosed is a Fast -Track Application submittal and supporting documentation for the above referenced project, for the Division's review and comment. This project consists of the construction of a gravity sewer line, new wastewater pump station and associated force main serving the North Wilkesboro Speedway and surrounding area in Wilkes County. The project includes construction of 4,800 linear feet of 8-inch gravity sewer, a new 210 gpm duplex submersible wastewater pump station, and approximately 4,100 linear feet of 6-inch force main to transfer wastewater from the North Wilkesboro Speedway property to the nearest gravity wastewater collection system owned and operated by the Town of North Wilkesboro. Based upon the design flow rates provided in 15A NCAC 02T .0114 for Stadium facilities, a daily design flow of 100,000 gallons per day is anticipated from the Speedway. The proposed 6-inch force main will discharge into an existing manhole located near the intersection of Speedway Road and NC Hwy 115. The downstream sewer from this location is to be upgraded as part of NCDOT's project R-5759 that will widen NC Hwy 115. The extent of the downstream wastewater collection system upgrades and remainder of the downstream sewer is shown in the included General Project Area map. This package has been prepared in accordance with 15A NCAC 02T and the "Fast Track Sewer System Extension Application." The following is included herein: • Application Form FTA 10-23 (1 original, 1 copy) • Flow Tracking/Acceptance Form FTSE 10-23 (1 original,1 copy) Site Maps (2 copies) Application Fee of $600.00 401 4"' Street, SW Suite 201 Hickory, NC 28601 Tel. 828.327.6911 www.wkdickson.com Aviation • Water Resources • Land Development • Energy August 7, 2024 Page 2 Pursuant to FTA 10-23, engineering design documents including drawings, technical specifications, and calculations were completed prior to submittal of this package and are available to the Division upon request. Please advise if there are any questions or comments. Sincerely, W. K. Dickson & Co., Inc. Jordan Isenhour, PE Senior Project Engineer Enclosures cc: Holly Minton — North Wilkesboro Town Manager