Loading...
HomeMy WebLinkAboutNCG550226_Staff Report_19921124 • SOC PRIORITY PROJECT Yes No If Yes, SOC No. cc: Permits and Engineering Technical Support Branch County Health Dept. Central Files WSRO RECEIVED To: Permits and Engineering Unit Water Quality Section NOV 2 4 1992 Attention : Mack Wiggins Date No v emb e r 19 . 1992 TECHNICAL SUPPORT BRANCH NPDES STAFF REPORT AND RE ONMEM)AT I CN County : Davidson ' Permit No . NCO-0-5-605-7- JJCGsso PART I - GENERAL INFOIMATICN 1 . Facility and Address : Mr . Jinmie R. Murdock Residence Route 1 , Box 804 Thomasville , N.C. 27360 2 . Date of Investigation : November 12 , 1992 3 . Report Prepared by : Mike Mickey , Environmental Technician V 4 . Persons Contacted and Telephone Number : Mr . Jimmy R. Murdock, ph (919) 475-0641 5 . Directions to Site : Take Hwy 109 south out of Winston-Salem and then turn right onto Old Greensboro Road (SR 1798) . Proceed to Turnpike Road (SR 1898) , turn left and the Murdock SFR is at the end of the road on the left . 6. Discharge Point (s) , List for all discharge points : Latitude : 35 ° 54 ' 03" Longitude : 80° 08 ' 50" U. S .G. S . Quad No . D18NN U. S .G. S . Quad Name Midway 7 . Site size and expansion area consistent with application? NA Yes No If No , explain : 8 . Topography ( relationship to flood plain included) : The lot and sandfilter system are located adjacent to , but out of the flood plain . 9 . Location of nearest dwelling : The Gary D. Eddigner Residence (NC0058670) is located across the street from the Murdocks . 10. Receiving stream or affected surface waters : U.T. to Rich Fork Creek. a . Classification : C b . River Basin and Subbasin No. : YAD-07 c . Describe receiving stream features and pertinent downstream uses : The U.T. joins Rich Fork Creek approximately 50 yards below Murdocks outfall . Mr . Eddinger ' s sandfilter discharges into the U.T. some 100 yards above Murdock' s outfall . PART II - DESCR I PT I Cni OF DISCHARGE AND TREATMENT WORKS 1 . a . Volume of Wastewater to be permitted : 0 . 0003 MD(Ultimate Design Capacity) b . What is the current permitted capacity of the Was to Water Treatment facility? 300 gpd c . Actual treatment capacity of the current facility (current design capacity) ? 300 based on the A/C issued 2/ 16/84 . d . Date( s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years : NA e . Please provide a description of existing or substantially constructed wastewater treatment facilities : The existing 300 gpd system consists of a 1000 gallon septic tank, a 270 square foot subsurface sandfilter , chlorinator and contact tank and discharge pipe . There is not a cascade aerator as specified in the A/C. f. Please provide a description of proposed wastewater treatment facilities : NA - existing g . Possible toxic impacts to surface waters : None known . h . Pretreatment Program (PGRWs only) : NA NPDES Permit Staff Report Version 10/92 Page 2 2 . Residuals handling and utilization/disposal scheme : Solids are removed from the septic tank by local haulers for disposal in the nearest POIW. a . If residuals are being land applied , please specify DHvi permit no .NA Residuals Contractor NA Telephone No . NA b . Residuals stabilization : NA PSRP PFRP_ Other c . Landfill : NA d . Other disposal /utilization scheme (Specify) : 3 . Treatment plant classification (attach completed rating sheet) : NA for SFR 4 . SIC Code( s) : 4952 Wastewater Code( s) : Primary 04 Secondary Main Treatment Unit Code : 4 4 0 X 7 PART III - OTHER PERTINENT INFOAVIATI(N 1 . Is this facility being constructed with Construction Grant Funds or are any public monies involved . (municipals only)? NA 2 . Special monitoring or limitations ( including toxicity) requests : NA 3 . Important SOC, JOC or Compliance Schedule dates : (Please indicate) NA 4 . Alternative Analysis Evaluation : Has the facility evaluated all of the non-discharge options available . Please provide regional perspective for each option evaluated . NA - existing Spray Irrigation : Connection to Regional Sewer System: Subsurface : NPDES Permit Staff Report Version 10/92 Page 3 Other disposal options : 5 . Other Special Items : PART IV - EVALUATION AND RE CMVI11 TI CNS Observations of the system on 11 - 12-92 did not reveal any problems . It was relevant to note , however , that the trailer had been removed so no discharge was occurring . The Murdocks are replacing their present 1 -bedroom mobile home with a double wide . The chlorine contact chamber is located downslope from the end of the driveway . The discharge pipe is approximately 50 yards in length and passes in front of the end of the gravel road and empties into the U.T. just below the driveway across the street . WSRO Recommends reissuance . - V-\;.kD.A.\'Nt.L , Signature of repor preparer ater Quality Regio al Supervisor ? Z// Zv Date NPDES Permit Staff Report Version 10/92 Page 4 ),., h°\ ° f` Mr. Jimmie R. Murdock Residence ,s'\ a ` NPDES Permit No. NC0056057 V )T _ % / '�I Discharges into a U.T. to Rich_Fork " - Creek, class "C" waters. i /jam - ,/ ,;, / ' 1 - _ ,Lr� Located at the end of Turnpike Road � l �;o � „ ! (SR1898) Northwest of Thomasville. ��/^�'!- l� 2= _ ' ° Davidson County D-18-SW r /,, -_� , le • _ 7` .` r ----so \ • , Q il �\= % o ) yO ' ,- � �59 1, cl/ oat - 1, - 2 •.A • - /-' 00 1:e. l • i_ , ,,, -------i- ,_,75o • 7.-, _ • • \ , , , • V O Q' -,›• \\ _ • * : . \ .r 0 • ••railer u Faitview\ _ . / u k ' • • o-r h lIV r. - al N • • •• ar • " \`.. 1p y ( �o° • `11 Q 1 c �ti. I \ rl ° Aso / lq n \ I. , •• / ,� '� III PI BM 7841 .11 • \\O i 11 `jam%• • j'�r "So ` fir:f'i' r\e • -1,./..../..r."- . 70.: ' /. fft� o -\\� 'ate 1• '1 - ~�✓ . `� • f Discharge Point El ',;;,e`'� • • ,�J'•II'' • .7 / r11 • • 8• . =i h ;xc • • Jim �RI, 574 575 10' 576 LEXINGTON 7 Ml. 577 • • INTERIOR--GEOLOGICAL SURVEY,RESTON,VIRGINIA-1987 800� SALISBURY 24 MI. 578000mE A. (1) . EFFLUENT LIMITATICt.S AND MONITORING REQUIREMEDTTS Final During the period beginning on the effective date of the permit and lasting until expiration, the permittee is authorized to discharge from outfall(s) serial number(s) 001. Such discharges shall be limited and monitored by the permittee as specified below: Effluent Characteristics Discharge Limitations Monitoring Requirements Kg/day (lbs/day) Other Units (Specify) Measurement Sample *Sample Monthly Avg. Weekly Avg. Monthly Avg. Weekly Avg. Frequency Location Flora 300 4 GPp BOD,5Day,20 C 30.0 mg/1 45.0 mg/1 Total Suspended Residue 30.0 mg/1 45.0 mg/1 NH3 as N Dissolved Oxygen (minimm►) 6.0 mg/1 6.0 mg/1 Fecal Coliform (geanetric mean) 1000.0/100m1 2000.0/100ml Residual Chlorine Temperature The chlorinator shall be inspected weekly to ensure there is an ample supply of chlorine tablets for continuous disinfection of the effluent. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. There shall be no discharge of floating solids or visible foam in other than trace amounts. NC0056057