Loading...
HomeMy WebLinkAboutWQ0000889_Monitoring - 07-2024_20240826 (3)Monitoring Report Submittal Permit Number#* Name of Facility:* Month:* July WQ0000889 PCS Phosphate Company Inc. Report Information Type * NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address: Name of Submitter: * Signature: Date of submittal: Initial Review Year:* 2024 Upload Document* Ju1y2024_Nutrien NDMR_NDAR_WQ0000889 .pdf 483.59KB PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). brittany.curtis@nutrien.com Brittany Curtis Reviewer: Wanda.Gerald 8/26/2024 This will be filled in automatically Is the project number correct?* WQ0000889 Is the monitoring report accepted?* Yes No Regional Office* Washington Reviewer: _anonymous Review Date: 8/27/2024 Jutrien- CERTIFIED MAIL August 26, 2024 Division of Water Resources Non -Discharge Compliance / Enforcement Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: Permit #WQ0000889 PCS Phosphate Company, Inc.' Wastewater Treatment Plant Monthly Report July 2024 Dear Mr. Bullock, Please find the attached digital copy of PCS Phosphate Company, Inc.'s Non -Discharge Monitoring Report (NDMR) and PCS Phosphate Company, Inc.'s Non -Discharge Application Report (NDAR-2), as required by condition IV.6 of the above referenced permit. Please do not hesitate to contact me at (252) 617-5374 if I can answer any questions or provide any additional information. Sincerely, Brittany Curtis Environmental & Technical Services Specialist Nutrien — Aurora Attachments ec: 12-04-01 w/attach J.C. Stroud w/attach L. D. Davis w/attach 1630 NC Hwy 306 South, Aurora, NC USA 27806 rr n itrien corn 1 Effective January 1, 2018, PCS Phosphate Company, Inc. is an indirect subsidiary of Nutrien Ltd. PCS Phosphate Company, Inc. remains the legal operating entity and permittee. FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page _1_ of _2_ Permit No.: W00000889 Facility Name: PCS Phosphate WWTP County: Beaufort Month: July Year: 2024 Did infiltration occur at Site Name: 1 Site Name: 2 Site Name: 3 Site Name: this facility? 0 YES ❑ Area (acres): 0.15 Area (acres): 0.15 Area (acres): 0.15 Area (acres): No Rate (GPD/ft): 4.99 Rate (GPD/ft): 4.99 Rate (GPD/ft): 4.99 Rate (GPD/ft): Weather Freeboard Site Infiltrated? 2 YES Oi NO Site Infiltrated? ❑ YES p No Site Infiltrated? (] YES I3 NO Site Infiltrated? ❑ YES ❑ NO o C� 3 *'• a W S ry a ®� 9 wa V% l0 a A c+ Ra G 10 �" m° E m oa Q ro ®� �E'-- C °� ?, c oo J ° 0 0 m� 1 •w LLm d a E d oa= 9 Q m C of 1, S p� J ° 0 0 m0 2 `. m .a E m ca Q M m w E� ~ C a+ a C eon -a 0 0 me fA LLm E d 0Q' � Q V d :; Ew ~ C �, 100 J T �, o p �c ` 'y LLm °F in I ft ft gal min GPDM2 ft gal min GPD/ft2 ft gal min GPDM2 ft gal min GPD/ft2 ft 1 R 75 0.191 3,853 144 0.59 2 C 78 0 4,160 162 0.64 3 C 79 0.01 5,040 192 0.77 4 80 0 HOL 3,730 129 0.57 5 C 83 0 3,730 129 0.67 6 83 0.04 4,266 202 0.65 7 84 2.17 4,266 202 0.65 8 C 82 0.141 4,266 202 0.65 9 C 85 0.14 3,600 94 0.55 10 C 85 0 2,100 59 0.32 17 C 86 0 1,200 32 0.18 121 PC 81 0.21 3,610 100 0.55 131 82 1.18 1,716 63 0.26 14 89 0.53 1,716 63 0.26 15 C 89 0 1,716 63 0.26 16 C 87 0 2,700 26 0.41 17 C 84 0 1 2,600 1 63 0.40 18 R 82 0 3,900 106 0.60 19 PC 80 0 2,410 58 0.37 20 85 0 3,721 99 0.57 21 82 0 3,721 99 0.57 22 PC 82 1.61 3,721 99 1 0.57 23 PC 84 0.14 2,390 66 0.37 24 R 1 83 0.01 3,500 114 0.54 25 R 81 1 0.24 1 3,850 59 0.59 26 R 78 2.15 2,610 75 0.40 27 80 0.63 2,941 79 0.45 28 78 0 2,941 79 0.45 29 PC 75 0 2,941 79 0.45 30 C 80 0 2,300 90 0.35 31 C 82 0.01 2,300 84 0.35 Monthly Loading (GPD/ftEMMM 0.47 #DIV/01 rill= 0.50 #DIV/0! Year to Date Loading GPD/ft2 FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page _2_ of _2_ Did the application rates exceed the limits in Attachment B of your permit? If not a basin, were the sites kept free of vegetation and raked? If not a basin, were there any instances of effluent ponding in or runoff from the sites? If a basin, were there any instances of breakout from the berms? 21 Compliant ❑ Non -Compliant 21 Compliant ❑ Non -Compliant 2 Compliant ❑ Non -Compliant Z Compliant ❑ Non -Compliant Was the onsite automatically activated standby power source tested and operational? O Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification ORC: Larry D Davis Jr. Certification No.: 1004832 Grade: WW IV Phone Number: (252) 322-8111 ext. 8656 Has the ORC changed since the previous NDAR-2? ❑ Yes O No Signature By this signature, I certify that this report is accurrate and complete to the best of my knowledge. Permittee Certification Permittee: PCS Phosphate Company, Inc. Signing Official: William M. Ponton Signing Official's Title: General Manager Phone Number: (252)322-8283 Permit Exp.: 4/30/28 Date Signature Date I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: WQ0000889 Facility Name: PCS PHOSPHATE WWTP County: Beaufort Month: July Year: 2024 PPI: 001 Flow Measuring Point: ❑ Influent 0 Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent I] Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code --► 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00530 a (3K Q ~ C 0 _ . v m ~00, m,E 0 E Ep a c $ 9'° . x a a 6 Hy ° .mE ca ton in 1 24-hr 07:00 hrs 9.5 GPD 3,853 mg/L mg/L I mg/L #/100 mL mg/L mg!L mg/L mg/L su 7.34 mg/L mg/L mg/L 2 07:00 9.5 4,160 7.25 3 07:00 9.5 5,040 7.27 4 5 Holiday 07:00 9.5 3,730 3,730 Holiday 7.32 6 4,266 7 4,266 8 07:00 9.5 4,266 7.51 9 07:00 9.5 3,600 7.29 10 07:00 9.5 2,100 7.31 11 07:00 9.5 1,200 <2.0 178 <1 <0.02 1.98 15.6 17.6 7.15 6.02 <2.5 12 07:00 9.5 3,610 7.28 13 1,716 14 1,716 15 07:00 9.5 1,716 7.15 07:00 9.5 2,700 7.21 116 17 07:00 9.6 2,600 7.32 18107:00 9.5 3,900 7.25 19 07:00 9.5 2,410 7.3 201 3,721 211 3,721 221 07:00 9.5 3,721 7.26 231 07:00 9.5 2,390 7.3 3 24 07:00 9.5 3,500 7 251 07:00 9.5 2,850 7.35 26 07:00 9.5 2,610 7.33 27 2,941 28 2,941 29 07:00 9.5 2,941 7.21 30 07:00 1 9.5 2,300 7.32 311 07:00 1 9.5 2,300 7.43 Average: 3,113 0.00 178.00 1.00 0.00 1.98 15.60 17.60 1 6.02 0.00 Daily Maximum: 5,040 2.00 178.00 1.00 0.02 1.98 15.60 17.60 7.51 6.02 2.50 Daily Minimum: 1,200 2.00 178.00 1.00 0.02 1.98 15.60 17.60 7.15 6.02 2.50 Sampling Type: Monthly Avg. Limit: Recorder Composite 10 Composite Grab Grab 200 Composite 4 Composite, Composite Composite Grab Composite Composite Composite 5 Daily Limit: 30,000 15 6 (6-9) 10 Sample Frequency:1 Continuous Monthly 3x Year Per Event Monthly Monthly Monthly Monthly Monthly 5 x Week Monthly 3 x Year Monthly FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Sampling Person(s) Certified Laboratories Name: Larry D.Davis, Jr. Name: Waypoint Incorporated Id. 10 Name: Name: PCS Phosphate Inc. ID 330 uoes all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? ❑O Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additinnal chants if naraccary Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Larry D. Davis, Jr. Permittee: PCS Phosphate Inc. Certification No.: 1004832 Signing Official: William M. Ponton Grade: WW IV Phone Number: 252-322-8111 ext 8656 Signing Officials Title: General Manager Has the ORC changed since the previous NDMR? ❑ Yes O No Phone Number: 252-322-8283 Permit Expiration: 4/30/2028 Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617