Loading...
HomeMy WebLinkAboutSW4240503_Supplement-EZ Form_20240823 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name WILDERNESS RESERVE PHASE 3 2 Project Area ac 54.48 3 Coastal Wetland Area ac 0 4 Surface Water Area ac 0 5 Is this project High or Low Density? Low 6 1 Does this project use an off-site SCM? No MPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided feet >100 FT 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is ro osed in the setback,does it meet NCAC 02H.1003 4 o-d ? N/A 10 Is streambank stabilization proposed on this project? No BER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting RWH 18 Green Roof 19 Level Spreader-Filter Strip LS-FS 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 Dry Pond 23 StormFilter r2624 Silva Cell 25 Bayfilter Filterra FORMS LOADED SIGNER CERTIFICATION Name and Title: GREG GOTSCH L929 Or anization: LAND RESOURCE MANAGEMENT Street address: 118 CHERRY ST Cit ,State,Zip: BLACK MOUNTAIN, NC 28711 31 Phone numbers: 828 900-8700 32 Email: GREG@LANDRM.COM Certification Statement: certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer ``pu�u��li�lpii Signature of Designer �'.,� ,p'••.........••'G o`er 5/28/2024 Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so,number of drainage areas/SCMs 0 3 Does this ro'ect have low density areas? NO 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? Yes FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 4 Type of SCM N/A 5 Total BUA from project(sq ft) 167770 sf 6 1995 rules SL 2006-246 2008 rules 2017 rules New BUA on subdivided lots(subject to 7 permitting)(sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules New BUA not on subdivided lots(subject to 8 permitting)(sf) 1995 rules SL 2006-246 2008 rules 2017 rules 9 Offsite-total area(sq ft) sf sf 1995 rules SL 2006-246 2008 rules 2017 rules 10 Offsite BUA(sq ft) sf sf 1995 rules SL 2006-246 2008 rules 2017 rules 11 Design storm(inches) NA NA 1995 rules SL 2006-246 2008 rules 2017 rules 12 Breakdown of new BUA: -Parking(sq ft 23106 sf -Sidewalk(sq ft sf -Roof(sq ft 86913 sf -Roadway s ft 57749 sf -Future(sq ft sf -Other,please specify in the comment box below(sq ft sf New infiltrating permeable pavement on 13 Isubdivided lots(sq ft NA New infiltrating permeable pavement not on 14 subdivided lots(sq ft NA Existing BUA that will remain(not subject to 15permitting) s ft NA 16 Existing BUA that is already permitted(sq ft NA sf 17 Existing BUA that will be removed(sq ft NA 18 Percent BUA 7% 19 1 Desi n volume of SCM cu ft cf 20 1 Calculation method for design volume NA ADDITIONAL INFORMATION Please use this space to provide any additional 21 information about the drainage area(s): DRAINAGE AREA INFO IS ONLY FOR WATERSHED WITHIN AN ORW WATERSHED. LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 021-1.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 2 sf 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 7.6 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) NA 8 Bottom width of curb outlet swale(s)(feet) NA 9 Maximum side slope of curb outlet swale(s)(H:V) NA 10 Minimum length of curb outlet swale(s)(feet) NA 11 Are treatment swales used instead of curb outlet swales? Yes 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 lAre variations to rule.1003 proposed? I No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: ALL AREA IS WITHIN ORW Drainage Pervious Swale A BUA area C Q Slope V,i„w V,�,,,i Flow depth Area# re (ac) ac (cfs) (%) (fps) (fps) (ft) fac1 0.64 0.22 0.42 0.49 2.18 5.66 15.00 0.90 11.16 2 0.68 0.04 0.64 0.29 1.38 11.41 15.00 1.10 7.68 3 4 5 1.11 0.11 1.00 0.32 2.44 11.95 15.00 1.27 9.96 6 0.51 0.14 0.37 0.45 1.57 13.16 15.00 1.19 7.92 7 0.08 0.08 0.00 0.95 0.52 13.16 15.00 0.60 2.40 8 0.14 0.06 0.08 0.56 0.54 12.16 15.00 0.87 4.80 9 0.71 0.20 0.51 0.45 2.21 11.48 15.00 1.21 9.60 10 1.22 0.35 0.87 0.45 3.78 11.46 15.00 7.58 4.08 11 0.27 0.27 0.01 0.94 1.75 11.46 15.00 0.79 4.56 12 0.79 0.28 0.51 0.50 2.70 8.65 15.00 1.16 11.28 13 0.12 0.07 0.05 0.67 0.55 5.82 15.00 0.66 5.76 14 0.06 0.03 0.03 0.66 0.27 5.82 15.00 0.54 3.96 15 16 0.22 0.12 0.10 0.63 0.96 12.74 15.00 1.01 6.36 17 0.42 0.16 0.26 0.52 1.50 12.93 15.00 1.15 7.80 18 0.47 0.17 0.30 0.51 1.65 13.03 15.00 1.19 8.16 19 20 21 22 23 24 25 26 27 28 29 30