Loading...
HomeMy WebLinkAboutNC0087106_Authorization to Construct_20020315.N William G. Lapsley & Associates, P.A. Consulting Engineers and Land Planners 1635 Asheville Highway Post Office Box 546 Hendersonville, North Carolina 28793 828-697-7334 - FAX 828-697-7333 March 15, 2002 Ms. Jacquelyn M. Nowell NPDES Permit Unit NC Division of Water Quality T 1617 Mail Service Center D Raleigh, NC 27699-1617 i �u Re: Champion Hills WWTP MAR 19 2002 Permit N00087106. A/C #0087106 DENR - WATER QUALITY SOURCE BRAN^N Henderson County POINT SO Dear Ms. Nowell: Enclosed for your records please find the Engineer's Certification for the above referenced project. William G. Lapsley, P.E. William R. Buie, P.E. G. Thomas Jones III, P.E. Wm. James Jones, P.E. Please note that it was not necessary to upgrade the -existing effluent pumps included in the approved plans. During a test run of the existing pumps the system worked find therefore, new pumps are not required. If you have any questions or concerns please feel free to contact our office. WGL/ds cc: Lee Weber, Champion Hills 0- Printed on Recycled Paper gut No. NC0087106 "ithorization to Construct WWTP .:hampion Hills January 25, 2002 a Page 3 Engineer's Certification I, WA%b^ G. La duly registered Professional Engineer in the State of North Carolina, having been nut horiz d to observe (periodically, e) the construction of the project, 5� w �m Wt VMC60KWS NAM for the o� Projeck Name Location Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following installations: • the installation of a tee(s) in the existing effluent force main with two (2) control valves, • the installation of 4" � effluent force main to the receiving stream, an unnamed tributary of South Fork Big Willow Creek • the upgrading of the dual pumps of the effluent discharge lift station from 5 HP to 7 %Z HP for the above referenced project such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications: The permittee must comply, even during the construction phase, with all limits required by the NPDES permit. Once construction under this ATC has been completed and an Engineer's Certificate has been submitted, the permittee is authorized to operate the new treatment units. Sign Date In addition, please check one of the following: -4- F •. C, • SEAL ' 669 !�w••• r A� r `l� • ` �4ti �+` . Vlea� •' ��yy -'•....••'S� ,I,��ivvw��,' E G Tad` `i` ire: . ►a,a`a� • There are still some major components that require completion. Another Engineer's Certificate will be submitted once all substantial construction has been completed. All substantial construction has been completed. The Division of Water Quality hereby receipt and acceptance of Bn t� on State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director January 25, 2002 Mr. Lee J. Weber Champion Hills POA, Inc. 1 Hagen Drive Hendersonville, North Carolina 28739-8964 Dear Mr. Weber: L19.9�VA NCD NR Subject: Permit No. NCO087106 ATC Number 087106AO I Champion Hills WWTP Henderson County The Division received a letter of request for Authorization to Construct on October 16, 2001. Final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the installation of an effluent discharge line. Specifically, this ATC allows: the installation of a tee(s) in the existing effluent force main with two (2) control valves, the installation of 4" 0 effluent force main to the receiving stream, an unnamed tributary of South Fork Big Willow Creek the upgrading of the dual pumps of the effluent discharge lift station from 5 HP to 7 %Z HP This Authorization to Construct is issued in accordance with Part III, Paragraph C of NPDES Permit No. NCO087106 issued September 25, 2001 and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0087106. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division of Water Quality in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. In the event that the facility fails to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Asheville Regional Office, telephone number (828) 251-6208, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on -site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct, and the approved plans and specifications. Mail the completed certification to: North Carolina DENR-DWQ, NPDES Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper Permit No. NCO087106 Authorization to Construct Champion Hills WWTP January 25, 2002 Page 2 One (1) set of approved plans and specifications is being forwarded to you. A copy of the approved plans and specifications shall be maintained on site by the Permittee for the life of the facility. If you have any questions or need additional information, please contact Jacquelyn M. Nowell, telephone number (919) 733-5083, extension 512. Sincerer Gregory J. Thorpe, Ph.D. cc: Central Files NPDES Unit Asheville Regional Office, DWQ Technical Assistance and Certification