Loading...
HomeMy WebLinkAboutNC0070033_Fact Sheet_20240815 (2)Docusign Envelope ID: 728D37AC-234C-42F6-BE47-D0654BB880EC NCDEQ / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT RENEWAL NPDES Permit NCO070033 Catherine Shadwell, Compliance & Expedited Permitting Unit / 919-707-3613 April 2024 FACILITY INFORMATION Applicant/Facility Name Quail Run MHP Pads LLC (attn Kevin Murray, Owner) Quail Run Mobile Home Park Applicant Mailing Address 113 Center St Suite 201 Lexington NC 27292 Facility Physical Address 136 Quail Place Dr Winston-Salem NC 27127 Permitted Flow (MGD) 0.017 MGD Type of Waste 100% Domestic, < 1 MGD Facility Class WW-1 County Davidson Permit Status Renewal Regional Office WSRO STREAM CHARACTERISTICS Receiving Stream Miller Creek Stream Classification C Stream Segment 12-94-14 Outfall Lat. 350 59' 12.1" N 7Q10 - Summer (cfs) 0.2 Outfall Long. 800 15' 59" W 7Q 10 - Winter (cfs) 0.4 Drainage basin Yadkin -Pee Dee 30Q2 (cfs) 0.5 Subbasin 03-07-04 Average Flow (cfs) 1.4 HUC 030401011308 IWC (%) 11.64% (summer) / 6.18% (winter) 303(d) List Not listed. BASIC INFO FOR EXPEDITED PERMIT RENEWAL Does permit need Daily Max NH3 limits? Already present in permit Does permit need TRC limits/footnote? Already present in permit Does permit have toxicity testing? No Does permit have any Special Conditions? Yes, nutrient reopener for High Rock Lake Does permit have instream monitoring? Yes, Upstream and Downstream for temperature and DO New expiration date: May 31, 2029 Facility Summary Quail Run MHP Pads LLC operates a minor (flow < 1 MGD) wastewater facility to serves a Mobile Home Park of about 100 residents. Quail Run Mobile Home Park's WWTP treats 100% domestic wastewater and has a design capacity and permitted flow of 0.017 MGD. The WWTP was originally permitted in 1987. This facility utilizes the following treatment components: • Two 3,200-gallon septic tanks • 4,000-gallon septic tank • Two 4,500-gallon septic tanks • 8,400-gallon recirculating dosing tank • 4,250 ftz recirculating surface sand filter • Tablet chlorinator • 350-gallon chlorine contact tank • De -chlorination contact tank* *observed by WSRO staff at recent inspection but not listed on previous component list. Fact Sheet for Permit Renewal April 2024 - NPDES Permit NCO070033 - Page 1 Docusign Envelope ID: 728D37AC-234C-42F6-BE47-D0654BB880EC Renewal Summary This renewal contains the following changes: • Updated Section A. (3.) to reflect current federal requirements for Electronic Reporting of Discharge Monitoring Reports. • Updated outfall map • Updated winter ammonia limits per NCAC 2B .0404(c) — Winter limits can be no less stringent than 2 times the summer limits. New winter ammonia limits will go into effect January 1, 2029. Compliance History Looking through the past 5 years (since 2019), this facility has received 8 NOVs and 3 NODs. 5 out of the 8 NOVs were due to an exceedance of Fecal Coliform. The most recent inspection (performed June 2023) found that the facility was taking upstream samples in an UT, instead of the permitted 100ft upstream of the outfall. There were also observations of ponding in the sand filter; as well as discrepancies in the 5 septic tank locations, and use of the chlorination and dechlorination systems. Comments on Draft Permit Fact Sheet for Permit Renewal April 2024 - NPDES Permit NC0070033 - Page 2 Docusign Envelope ID: 728D37AC-234C-42F6-BE47-D0654BB880EC IWC Calculations Facility: Quail Run Mobile Home Park Permit No.: NC0070033 Prepared By: Catherine Shadwell Enter Design Flow (MGD): 0.017 <= Permitted Flow if Different from Design Enter s7Q10 (cfs): 0.2 Enter w7Q10 (cfs): 0.4 Total Residual Chlorine (TRC) Ammonia (Summer) Daily Maximum Limit (ug/1) Monthly Average Limit (mg NH3-N/1) Design Permitted Design Permitted s7Q10 (CFS) 0.2 s7Q10 (CFS) 0.2 DESIGN FLOW (MGD) 0.017 € DESIGN FLOW (MGD) 0.017 € DESIGN FLOW (CFS) 0.02635 DESIGN FLOW (CFS) 0.02635 STREAM STD (UG/L) 17.0 STREAM STD (MG/L) 1.0 Upstream Bkgd (ug/1) 0 Upstream Bkgd (mg/1) 0.22 IWC (%) 11.64 IWC (%) 11.64 Allowable Conc. (ug/1) 146 Allowable Conc. (mg/1) 6.9 Ammonia (Winter) Monthly Average Limit (mg NH3-N/1) Design Permitted Design Permitted Fecal Coliform w7Q10 (CFS) 0.4 Monthly Average Limit: 200/100ml € #VALUE! DESIGN FLOW (MGD) 0.017 (If DF >331; Monitor) DESIGN FLOW (CFS) 0.02635 (If DF<331; Limit) STREAM STD (MG/L) 1.8 Dilution Factor (DF) 8.59 #VALUE! Upstream Bkgd (mg/1) 0.22 IWC (%) 6.18 Allowable Conc. (mg/1) 25.8 *2B .0404 (c) Applies Total Residual Chlorine 1. Cap Daily Max limit at 28 ug/I to protect for acute toxicity Ammonia (as NH3-N) 1. If Allowable Conc > 35 mg/l, Monitor Only 2. Monthly Avg limit x 3 = Weekly Avg limit (Municipals) 3. Monthly Avg limit x 5 = Daily Max limit (Non-Munis) If the allowable ammonia concentration is > 35 mg/L, no limit shall be imposed By Policy dischargers < 1 MGD get limits no lower than 2 & 4 due to BAT * From 2B .0404(c) - Winter Limits can be no less stringent than 2 times the summer limits Fecal Coliform 1. Monthly Avg limit x 2 = 400/100 ml = Weekly Avg limit (Municipals) = Daily Max limit (Non -Muni) Docusign Envelope ID: 728D37AC-234C-42F6-BE47-D0654BB880EC 70097050 70961415 AFFIDAVIT OF PUBLICATION STATE OF NORTH CAROLINA LEXINGTON, NC May 16, 2024 DAVIDSON COUNTY I, Lynn Bowers OF THE DISPATCH, A NEWSPAPER PUBLISHED IN THE CITY OF LEXINGTON, COUNTY AND STATE AFORESAID, BEING DULY SWORN, SAYS THE FOREGOING LEGAL OF WHICH THE ATTACHED IS A TRUE COPY, WAS PUBLISHED IN SAID NEWSPAPER ONCE A WEEK FOR 1 WEEK, BEGINNING THE16th DAY OF May, 2024. PUBLICATION FEE: $ 99.55 �I (SEAL) 8C. LPOLe ORN TO AND SUBSCRI D B E, THIS I3�hDAY OF l MY COMMISSION EXPIRES COURTNEY L LOHR NOTARY PUBLIC Davidson County, North Carolina My Commission Expires 08/0312026 Ad Copy: Public Notice North Carolina Environmental Management Commission/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Notice of Intent to Issue NPDES Wastewater Permit NCO070033 Quail Run Mobile Home Park WWTP-North Carolina Environmental Management Commission proposesto issue a NPDES wastewater discharge permitto the person(s) listed below. Written comments regarding the proposed permit will be accepted until 30 days after the publish date of this notice. The Director of the NC Division of Water Resources (DWR) may hold a public hearing should there be a significant degree of public Interest. Please mail comments and/or Information requests to DWR at the above address. Interested persons may visit the DWR at 512 N. Salisbury Street, Raleigh, NC 27604 to review the information on file. Additional information on NPDES permits and this notice may be found on our website: https://deq.nc.gov/public-notices-hearings,or by calling (919) 707-3601. Quail Run MHP Pads LLC [113 Center St Suite 201, Lexington, NC 27292] has applied for renewal of NPDES permit NCO070033 for Quail Run Mobile Home Park WWTP in Davidson County. The permitted facility discharges treated domestic wastewater to Miller Creek in the Yadkin -Pee Dee River Basin. Currently ammonia nitrogen, total residual chlorine, and fecal coliform are water quality limited. This discharge may affect future allocations in this portion of Miller Creek. May 16, 2024