HomeMy WebLinkAboutSW8081025_Compliance Evaluation Inspection_20081002 DIVISION OF WATER QUALITY INFILTRATION SYSTEM INVESTIGATION Complete and email this form to Vincent.LewisLncmail net If there are more than 7 areas to be tested, attach a second sheet /,� Scheduled Site Visit Date: lb/.L/Q f Time: /f -'6d Project Name: ►/ ave ,,c.teG'itri, Rd/CA County: e or Street Address: A J Ze'I°td� Ri, ?WrT- Directions from the nearest intersection of two major roads: N044 twee Gtta... Take. a alclr , 5ercedia Fast 43 // Sr, r . 81.2e2-- S 4 to evt. tee (2 fie i cQ d/d Pig nnC >1 acre being disturbed?,DYES ENO CAMA Major required? ES O Consultant Name: , aviit7 /4vvLiS Phone: aga 6S3 't)O4$ Consultant Firm Name: "IOt4S r&wte rt,x, P.4". iiexJ -A Akd Bore Number 1 2 3 4 5 6 7 a) Existing Ground Elevation 13.75' b)Proposed Bottom Elevation c) Difference (a minus b) d) Add 2 ft. (Min. Bore Depth) I . e) Hardpan Depth? f) Infiltration Rate OK? g)Approx. Elev. Of SHWT , 1 $" h) Max. lowest bottom elev. Comments S bi-6 ttkd4 r( Seth,/ Re fired Attachments: Legible vicinity map. 2,! Complete Soils Report. �3 PDF formatted site plan with the boring locations to be tested. Site plans should be emailed or hand-delivered only. Illegible faxed maps will not be accepted. All proposed infiltration areas and existing, active utility lines located within the proposed basin/trench must be marked and flagged. If these areas are not flagged, the Soils Scientist reserves the right to decline to do the investigation. If the proposed infiltration system will be located in an area of existing pavement and there is no open area nearby, equipment capable of breaking through the impervious layer must be provided. The soils investigation does not take the place of a soils report prepared by an appropriate professional. The Soils Scientist will only verify the soil conditions that are reported in the Soils Report, and make a determination as to the suitability of the site to meet the infiltration design requirements under NCAC 2H.1000, and assumes no liability should the system fail. S:1WQSISTORMWATER\FORMS\infiltration site visit.for Revised 8.07 - ECS CAROLINAS,LLP imaseos.INA$ Geotechnical•Construction Materials•Environmental•Facilities September 11,2008 Mr.Kevin Avolis,P.E. Avolis lhnleo ,P.A. P.O.Box 15564 New Bern,North Carolina 28403 Re: Infiltration Evaluation Morehead City Police Department Morehead City,Carlcral County,North Carolina ECS Proj cot No.22.143 86C Dear Mr.Avolis, ECS Carolinas, LLP (ECS) recently conducted an infiltration evaluation for the proposed infiltration area at the above referenced site located off of Tenth Street and Bridges Street in Morehead City,Carteret County,North Carolina. This letter,with attachments, is the report of our evaluation. Field Testing On September 9,2008 ECS met with Mr.Kevin Avolis with Avolis Engineering on site in order to provide the requested test location. BCS then conducted an exploration of the subsurface soil and groundwater conditions at one requested location shown on the attached Site Diagram. The purpose of this exploration was to obtain subsurface information of the hi-place soils for the proposed infiltration area. ECS explored the subsurface soil and groundwater conditions by advancing one baud auger boring into the existing ground surface at the requested boring location. ECS visually classified the subsurface soils and obtained representative samples of each soil type encountered. ECS also recorded the groundwater and seasonal high water level (SHWL) observed at the time of the hand auger baring. The attached Infiltration Evaluation Form provides a summary of the subsurface conditions encountered at the hand auger boring location. The groundwater and SHWL were estimated at the boring location below the existing grade elevation. Below is a summary of the boring location. The surface elevation was provided by Avolis Engineering. Location SHWL Surface Elevation ' Groundwater 1 48 inches , 13.75' 70 inches ECS has conducted an infiltration test utilizing a compact constant head permeameter near the hand auger boring to estimate the infiltration rate for the subsurface soils. Infiltration tests are typically conducted at two feet above the SHWL. 7211 Ogden Business Part•Suite 2010 Wilmington,NC 28411.(910)686-9114•Fax(910)686-9665•www.ecdimited.com Asheville,NC•Charlotte,NC•Greensboro,NC•Greenville,SC•Raleigh,NC•Swansboto.NC*•Wilmington.NC *testing services only CEO" Infiltration Evaluation Morehead City Police Department Morehead City.Carteret Cowl '.North Carolina ECSProject No.22.14386C r.r Septernberll.2008 Field Test Results Below is a summary of the infiltration test results: Location Description T Depth _ Inches/hour 1 Brown fine 24 inches 9.4 SAND Infiltration rates and SHWL may vary within the proposed site due to changes in elevation and subsurface conditions. If you have any questions regarding this report,please contact us at(910)686-9114. Respectfully, RCS CAROLINAS,LLP )74 e/...4 144' K Brooks Wall Walid M.Sobb,P.E. Staff Geologist Principal Engineer NC License No.22983 Attachments: Figure 1-Test Location Plan Infiltration Evaluation • R ;.4,•0":. ' ,may /3 i .• , .ii,, ,,- iiirrli,,..,_. Tercmintiimirati, , ,•'; _ • •:_1 - lalakk,"11,1111111111111/111110111:1101111114 oia fa k]94 i ' t F • -•-y, Y r1 `' 5 + �* f " ��F4 �µ - 'ir , II� : _ ���4� ' - - --� t iSiTiI I1N I1fir I CI r �• 't _jI- .1'' y ' IT . T r fir,'!„jr,, t -� e? i y L = r ;II,_ : s• V I litl,i, , •,,, ......'"Elr... .. 2 ltilla Ell --- - - -- --1.1ftille. w 1 . 11 ''' 1 III t.. „ "�,+,r ~\1• i I ; i t t {I� 1 . 1 - , r5, am 7111 • {� .��' • . r I ! . j Ery r 1 ' till 1sr " I +I P i 1 r �I',. i ;411 1 1 - Z 61271) IN , r,a r r , i PGA31 yetP3) it INN -0efnaggEzen. ishieeeimeje II il ipleirisii lug din EP TEST LOCATION A Morehead City Police Department Morehead City,NC Figure 1-Test Lacadon Plan RCS Project No.22-143116-C Provided by: Melts Engineering, September 9,2008 Yi$W CliAllitC01.11NASII J • fir ' ` Infiltration Evaluation L Morehead :� CityPolice Department ' .:z< Morehead City, Carteret County,North Carolina ECS Project No. 22.14386C September 9, 2008 ocatiAII Soil Description 1 0-24" Brown fine SAND w/little silt 6"-60" Brown fine to medium SAND Seasonal High Water Table was estimated to be at 48 inches below the existing grade elevation. Infiltration Rate: 9.4 inches per hour elevation Test was conducted at 24 inches below existing gradea elevation. Ground water was encountered at 70 inches below the existing grad FWATF \O�O RpG Michael F.Easley,Governor y William G.Ross Jr.,Secretary North Carolina Department of Environment and Natural Resources t7 y .1'�— Coleen H.Sullins Director Division of Water Quality September 30, 2008 R. Randy Martin, City Manager Town of Morehead City 706 Arendell Street Morehead City, NC 28557 Project Name: Moehead City Police Department County: Carteret County Dear Mr. Martin: Your recent State Stormwater Management Application and check#12017 for the $505.00 application fee are being returned because the application lacked the necessary basic elements to accept it for review. The plans and any other documentation that were submitted have been discarded or recycled, as appropriate. Please address the following noted deficiencies and provide the requested information: ® According to Kevin Avolis with Avolis Engineering, PA, Vincent Lewis, a soil scientist with DENR, has not yet conducted an infiltration site visit, which is required for all infiltration projects proposed in counties served by the Wilmington Regional Office. Please submit the Infiltration System Investigation request form to Mr. Lewis in order to schedule a site visit. ® Please verify whether or not this site already has a permit. According to the narrative included with the application package, this site had been previously develop and utilized as the Morehead City Elementary School. According to the DWQ permit database, Morehead City Elementary School has an active low-density stormwater permit, SW8 921104. ® Evaluate the need for additional inlets into the infiltration basin. Each inlet should handle a maximum volume of 2 acre-inch. ® The wetlands note on plan sheet C1 indicates that no Section 404 wetlands are located within the project limits. Are there non-Section 404 wetlands present? If so, please delineate. Please resubmit the permit application package to the address below. Note that the 90-day statutory permit review time begins upon receipt of a complete application. If you have any questions, please do not hesitate to call me at (910) 796-7215. Sincerely, CRelki\D f)(g--Q3kr--) Christine Nelson Environmental Engineer cc: Kevin Avolis, Avolis Engineering, PA Wilmington Regional Office Christine Nelson ENB/can: S:1WQSISTORMWATIRETURN\Morehead City Police Dept.sep08 N,�i!hhCaro a dvatural�ly North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington,NC 28405 Phone(910)796-7215 Customer Service Wilmington Regional Office Internet: www.ncwaterquality.org Fax (910)350-2004 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer—50%Recycled/10%Post Consumer Paper 12017 1 AVOLIS ENGINEERING, P.A. 4 FIRST CITIZENS PO BOX 5405 MORTON RD BANK NEW BERN,NC 28561 66-30-531 9/22/2008 252-633-0068 5 'AY R�ER of 1,1 NCDENR $ ""505.00 Five Hundred Five and 0 Oil 00""""""""""****"*****************"**""******"************************************************** DOLLARS NCDENR N 8 )-2......_______ . MEMO AUTHORIZED SIGNATURE STORMWATER-MHC POLICE DEPT ii'0L20L711' 1:0E31003001:00b1L243927911'