HomeMy WebLinkAboutSW6240203_Supplement-EZ Form_20240818 SAND FILTER
1 Drainage area number 1
2 Minimum required treatment volume(cu ft) 2402 sf
GENERAL MDC FROM 02H.1050
3 Is the SCM sized to treat the SW from all surfaces at build-out? Yco
4 Is the SCM located away from contaminated soils? Yes
5 What are the side slopes of the SCM(H:V)? :1
6 Does the SCM have retaining walls,gabion walls or other engineered Yes
side slopes?
7 Are the inlets,outlets,and receiving stream protected from erosion Yes
(10-year storm)?
8 Is there an overflow or bypass for inflow volume in excess of the Yes
design volume?
9 What is the method for dewatering the SCM for maintenance? Pump(preferred)
10 If applicable,will the SCM be cleaned out after construction? Yes
11 Does the maintenance access comply with General MDC(8)? Yes
12 Does the drainage easement comply with General MDC(9)? Yes
If the SCM is on a single family lot,does(will?)the plat comply with
13 General MDC(10)? N/A
14 Is there an O&M Agreement that complies with General MDC(11)? Yes
15 Is there an O&M Plan that complies with General MDC(12)? Yes
16 Does the SCM follow the device specific MDC? Yes
17 Was the SCM designed by an NC licensed professional? Yes
SAND FILTER MDC FROM 02H.1056
18 SHWT elevation(fmsl) 190
19 Type of sand filter(open or closed) Open
20 If closed,will the filter will be pre-cast or pour-in-place? Cast in Place
21 If closed,top of grate elevation(fmsl) _ 195
22 Is this sand filter designed to attenuate peak flows? Yes
Sediment Chamber
23 Volume that can be retained in the sediment chamber(cubic feet) 1499 cf
24 Will there be a permanent pool in the sediment chamber? Yes _
25 Bottom of the sediment chamber(fmsl) 189.50
26 Area of the sediment chamber(square feet) 999 sf
27 Physical depth of the sediment chamber(inches) 42 in
28 Ponding depth in the sediment chamber,above any permanent pool 18 in
(inches)
29 Elevation of top of weir between chambers(fmsl) 193
Sand Chamber
30 Volume that can be retained in the sand chamber(cubic feet) 1499 cf
31 Bottom of the sand chamber(fmsl) 189.50
32 Area of the sand chamber(square feet) 999 sf
33 Physical depth of the sand chamber(inches) 24 in
34 Ponding depth in the sand chamber,above the sand surface 18 in
(inches) _
35 Elevation of the bypass device(fmsl) 193
36 Type of bypass device weir
37 Mechanism for distributing flow over the sand surface multipe openings
38 Sand specification for sand chamber ASTM C33
39 Depth above underdrain pipe(inches) 18 in
40 Will the media be maintained to drain at least two inches per hour at Yes
the sand surface?
41 Is at least one clean-out pipe provided at the low point of each Yes
underdrain line?
42 Will clean-out•i•es be ca••ed? Yes
ADDITIONAL INFORMATION
43 Please use this space to provide any additional information about the
sand filter(s):
5.A cast in place structure has been designed with vertical walls to provide
adequate containement for the SCM.0:1 slopes for wall. 19. The
design is an open sand filter with a closed bottom. There is no cover on the
structure. The top elevation is 195.0'.
Sand Filter 1 12:52 PM 8/14/2024