Loading...
HomeMy WebLinkAboutSW6231203_Supplement-EZ Form_20240813 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Gillespie-B1.9 Solar Utility Station 2 Project Area(ac) 40.66 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 3.09 5 Is this project High or Low Density? Low 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 50' 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Laura Harris,P.E.,Project Engineer III-Team Lead 28 Organization: Booth&Associates,LLC 29 Street address: 2300 Rexwoods Drive,Suite 300 30 City,State,Zip: Raleigh,NC 27607 31 Phone number(s): 919-851-8770 32 Email: Laura.Harris@booth-assoc.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer `,,1111111CI,11�11i11/��i% Q�- SEAL 056748 Signature of Designer '9� G N E� ��; 4 R"�NP�.o` oe/o9/2o2-4- 4,00,qtooIu1111N1` Seal Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so,number of drainage areas/SCMs 0 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site LD 1 4 Type of SCM N/A N/A 5 Total drainage area(sq ft) 1771150 1771150 6 Onsite drainage area(sq ft) 1771150 1771150 7 Offsite drainage area(sq ft) 8 Total BUA in project(sq ft) 135447 sf 135447 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) New BUA not on subdivided lots(subject to 10 permitting)(sf) 11 Offsite BUA(sq ft) 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) 73461 sf 73461 sf -Sidewalk(sq ft) _ -Roof(sq ft) _ -Roadway(sq ft) 33656 sf 33656 sf -Future(sq ft) -Other,please specify in the comment box below (sq ft) 16946 sf 16946 sf New infiltrating permeable pavement on subdivided 13 lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to 15 permitting)(sq ft) 11384 sf 11384 sf 16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sq ft) 18 Percent BUA 8% 8% 19 Design storm(inches) 1.0 in 1.0 in 20 Design volume of SCM(cu ft) N/A N/A 21 Calculation method for design volume N/A N/A ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 'drainage area(s): Other BUA=Equipment Pad(16,822 sf)+Solar Panel Foundations(124 sf)= 16,946 sf LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) N/A 8 Bottom width of curb outlet swale(s)(feet) N/A 9 Maximum side slope of curb outlet swale(s)(H:V) N/A 10 Minimum length of curb outlet swale(s)(feet) N/A 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: There are no permanent vegetated conveyances,those shown in the drawing set are temporary and are to be removed once permanent vegetation is established. Drainage Pervious Swale Area BUA area Q Slope V,iio„ 11,„„,, Flow depth (ac) (ac) (ac) (cfs) (%) (fps) (fps) (n) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 2