HomeMy WebLinkAboutGW1--04736_Well Construction - GW1_20240812 WELL CONSTRUCTION RECORD(GW-1) For Internal Use Only:
1.Well Contractor Information:
Kaleb T. Hyde 14.WATER ZONES
FROM TO DESCRIPTION
Well Contractor Name
25 ft- 455 ft.
4436-A ft. ft.
NC Well Contractor Certification Number 15.OUTER CASING(for multi-cased wells)OR LINER(if ap licable)
Graham Well Drilling LLC FROM TO DIAMETER THICKNESS MATERIAL
0 ft• 60 ft. 6.25 in. SDR21 PVC
Company Name 16.INNER CASING OR TUBING(geothermal closed-loop)
2.Well Construction Permit#: FROM TO DIAMETER THICKNESS MATERIAL
List all applicable well construction permits(i.e.Ulf',County,State,Variance,etc.) 0 ft. ft. in.
3.Well Use(check well use): ft. ft. in.
17.SCREEN
Water Supply Well: FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL
❑Agricultural ❑Municipal/Public ft. ft. in.
❑Geothermal(Heating/Cooling Supply) CIResidential Water Supply(single) ft. ft. in.
El Industrial/Commercial ❑Residential Water Supply(shared) 18.GROUT
❑Irrigation ❑Wells>100,000 GPD FROM TO MATERIAL EMPLACEMENT METHOD&AMOUNT
Non-Water Supply Well: 0 ft' 17 ft. bentonite
❑Monitoring ❑Recovery 17 ft. 20 it bentonite
Injection Well:
ft. ft.
❑Aquifer Recharge ❑Groundwater Remediation
19.SAND/GRAVEL PACK(if applicable)
❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO MATERIAL EMPLACEMENT METHOD
❑Aquifer Test ❑Stormwater Drainage ft. ft.
❑Experimental Technology ❑Subsidence Control ft. ft.
OGeothermal(Closed Loop) ❑Tracer 20.DRILLING LOG(attach additional sheets if necessary)
❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) FROM TO DESCRIPTION(color,hardness,soil/rock type grain size,etc.)
ft. ft.
4.Date Well(s)Completed: 07/02/2024 Well ID# ft. ft.
ft. ft. r' " _
5a.Well Location: it , . J1
Rhonda Tyner ft. ft.
ft. ft. AUG 1 2 2024
Facility/Owner Name Facility ID#(if applicable)
Double Springs/Tobacco Branch, Almond, NC 28702 ft. ft.
Physical Address,City,and Zip ft. ft. D`F1`a ILA
Graham 21.REMARKS
County Parcel Identification No.(PIN)
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(if well field,one lat/long is sufficient) 22.Certification:
35 degrees 23' 0" N 83 degrees 38' 13" W /<a_14 7/2/2024
6.Is(are)the well(s): nPermanent or ❑Temporary Signature of Certified Wefl C actor Date
By signing this form,1 hereby certify that the well(s)was(were)constructed in accordance with
7.Is this a repair to an existing well: ❑Yes or fNo I5A NCAC 02C.0100 or I5A NCAC 02C.0200 Well Construction Standards and that a copy
If this is a repair,fill out known well construction information and explain the nature of the of this record has been provided to the well owner.
repair under-21 remarks section or on the back of this form.
23.Site diagram or additional well details:
8.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page to provide additional well construction info
construction,only 1 GW-1 is needed. Indicate TOTAL NUMBER of wells (add'See Over in Remarks Box).You may also attach additional pages if necessary.
drilled: 1 24.SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 455 (ft.) Submit this GW-1 within 30 days of well completion per the following:
For multiple wells list all depths if different(example-3@200'and 2@I00')
24a. For All Wells: Original form to Division of Water Resources (DWR),
10.Static water level below top of casing: 25 (ft-) Information Processing Unit,1617 MSC,Raleigh,NC 27699-1617
If seater level is above casing use"-"
24b.For Injection Wells:Copy to DWR,Underground Injection Control(IUC)
11.Borehole diameter: 6.25 (in.) Program,1636 MSC,Raleigh,NC 27699-1636
12.Well construction method: rotary
24c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the
(i.e.auger,rotary,cable,direct push,etc.) county environmental health department of the county where installed
FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producing over 100,000 GPD:Copy to DWR,CCPCUA
13a.Yield(gpm) 2 Method of test: air
Permit Program,1611 MSC,Raleigh,NC 27699-1611
13b.Disinfection type: HTH Amount: 18oZ
Form GW-I North Carolina Department of Environmental Quality-Division of Water Resources Revised 6-6-2018