Loading...
HomeMy WebLinkAboutSW4240401_Supplement-EZ Form_20240801 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Whitehall Village South 2 Project Area(ac) 6.874 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 30 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration_System _ 0 12 _Bioretention Cell 2 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting(RWH) 0 18 Green Roof 0 19 Level Spreader-Filter Strip(LS-FS) 0 20 Disconnected Impervious Surface pis) 0 21 Treatment Swale 0 22 Dry Pond 0 23 Storm Filter 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Charles P.Truby,Jr.PE PLS President 28 Organization: CPT Engineering and Surveying,Inc. 29 Street address: 4400 Tyning Street 30 City,State,Zip: High Point,NC,27265 31 Phone number(s): (336)812-8800 x 304 32 Email: chuckt@cptengineering.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer 00r4•rrrrr•. ck '10 ••� •'OFESS�O'' „is a:\.? I:\ Signature of Designer • SEAL r n 14984 E -7-p '4:91Net:0 � `•• ••`.4 P. TRv�/•••�• 01131\'1,`k Seal Yf•.•rrrr�r~ Date BIORETENTION CELL 1 Drainage area number 1 2 2 Minimum required treatment volume cu ft) 3341 cf 8506 cf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM(H:V)? 3:1 1:1 6 Does the SCM have retaining walls,gabion walls or other engineered side slopes? Yes Yes 7 Are the inlets, outlets,and receiving stream protected from erosion (10-year storm)? Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice _ 10 If applicable,will the SCM be cleaned out after construction? Yes Yes 11 Does the maintenance access comply with General MDC(8)? Yes No 12 Does the drainage easement comply with General MDC(9)? Yes Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with General MDC(10)? N/A N/A 14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes 17 Was the SCM designed by an NC licensed professional? Yes Yes BIORETENTION CELL MDC FROM 02H.1052 18 SHWT elevation(fmsl) 973.50 957.00 19 Bottom of the bioretention cell(fmsl) 976.72 968.70 20 Ponding depth of the design storm(inches) 12 in 12 in 21 Surface area of the bioretention cell(square feet) 3459 sf 8534 sf 22 Design volume of SCM(cu ft) 3341 cf 8506 cf 23 Is the bioretention cell used for peak attenuation? Yes Yes 24 Depth of peak attenuation over planting surface(in) 24 in 24 in 25 Height of peak attenuation outlet above the planting surface(in) 18 in 18 in 26 Infiltration rate of the in situ soil(inch/hour) NA NA 27 Diameter of the underdrain pipes(if applicable) 6 in 6 in 28 Does the design include Internal Water Storage(IWS)? Yes Yes 29 if so, elevation of the top of the IWS(fmsl) 979.5 971.5 30 Elevation of the planting surface(fmsl) 981 973 31 What type of vegetation will be planted? (grass,trees/shrubs, other)? Grass Grass 32 Media depth(inches) 30 in 30 in 33 Percentage of medium to coarse washed sand by volume 75-85% 75-85% 34 Percentage of fines(silt and clay)by volume 8-15% 8-15% 35 Percentage of organic matter by volume 5-15% 5-15% 36 Type of organic material Pine Bark Pine Bark 37 Phosphorus Index(P-Index)of media(unitless) 50 50 38 Will compaction be avoided during construction? Yes Yes 39 Will cell be maintained to a one inch/hour standard? Yes Yes 40 Depth of mulch,if applicable(inches) in in 41 Type of mulch, if applicable 0 0 42 How many clean out pipes are being installed? 5 10 43 Type of pretreatment that will be used: Rip-rap Forebay Rip-rap Forebay ADDITIONAL INFORMATION 44 Please use this space to provide any additional information about the bioretention cell(s): Proposed Bio-Cell#2 will require impermeable geo-membrane liner to top of sod(973.0) �3ioretention — '- _. 1 1:30 PM 7/31/2024 DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 2 3 Does this project have low density areas? No 4 If so, number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 4 Type of SCM Bio-cell Bio-cell Bio-cell 5 Total drainage area (sq ft) 243936 67953.6 175982.4 6 Onsite drainage area (sq ft) 243936 67953.6 175982.4 7 Offsite drainage area (sq ft) 0 0 0 8 Total BUA in project(sq ft) 144184 sf 40511 sf 103673 sf New BUA on subdivided lots (subject to permitting) 9 (sq ft) sf sf sf New BUA not on subdivided lots(subject to 10 permitting)(sf) sf sf sf 11 Offsite BUA(sq ft) sf sf sf 12 Breakdown of new BUA not on subdivided lots: - Parking (sq ft) 470 sf 470 sf sf -Sidewalk(sq ft) 7805 sf 1704 sf 6101 sf - Roof(sq ft) 83933 sf 23777 sf 60156 sf - Roadway(sq ft) 35685 sf 9749 sf 25936 sf - Future(sq ft) sf sf sf -Other, please specify in the comment box below (sq ft) sf sf sf New infiltrating permeable pavement on subdivided 13 lots(sq ft) sf sf sf New infiltrating permeable pavement not on 14 subdivided lots (sq ft) sf sf sf Existing BUA that will remain (not subject to 15 permitting)(sq ft) sf sf sf 16 Existing BUA that is already permitted (sq ft) sf sf sf 17 Existing BUA that will be removed (sq ft) sf sf sf 18 Percent BUA 59% 60% 59% 19 Design storm (inches) 1.0 in 1.0 in 1.0 in 20 Design volume of SCM (cu ft) 3341 cf 8506 cf 21 Calculation method for design volume SCS SCS SCS ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s):