HomeMy WebLinkAboutGW1--04669_Well Construction - GW1_20240809 WELL CONSTRUCTION RECORD (GW-1) For Internal Use Only:
1.Well Contractor Information:
Chris C Russell 14.WATER ZONES
FROM TO DESCRIPTION
Well Contractor Name
80 ft. 165 ft.
3254 A
ft. It.
NC Well Contractor Certification Number 15.OUTER CASING(for multi-cased wells)OR LINER(if ap llcable)
Russell Well Drilling, Inc FROM TO DIAMETER THICKNESS MATERIAL
0 ft• 61 ft. 6.25 in. SDR21 PVC
Company Name
16.INNER CASING OR TUBING(geothermal closed-loop)
2.Well Construction Permit#: 1 O36 FROM TO DIAMETER THICKNESS MATERIAL
List all applicable well construction permits(i.e.UIC,County,State,Variance,etc.) ft. ft. in.
3.Well Use(check well use): ft. It. in.
17.SCREEN
Water Supply Well:
PP Y FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL
❑Agricultural ❑Municipal/Public ft. ft. in.
❑Geothermal(Heating/Cooling Supply) OResidential Water Supply(single) ft. rt. in.
❑lndustrial/Commercial ❑Residential Water Supply(shared) 18.GROUT
❑Irrigation ❑Wells>100,000 GPD FROM TO MATERIAL EMPLACEMENT METHOD&AMOUNT
Non-Water Supply Well: 0 ft. 20 ft• Grout Poured
❑Monitoring ❑Recovery ft. ft.
Injection Well:
ft. ft.
['Aquifer Recharge ❑Groundwater Remediation
19.SAND/GRAVEL PACK(if applicable)
❑Aquifer Storage and Recovery OSalinity Barrier FROM TO MATERIAL EMPLACEMENT METHOD
❑Aquifer Test ❑Stormwater Drainage ft. ft.
❑Experimental Technology ❑Subsidence Control ft. ft.
❑Geothermal(Closed Loop) ❑Tracer 20.DRILLING LOG(attach additional sheets if necessary)
FROM TO DESCRIPTION(color,hardness,soil/rock type,grain size,etc.)
❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks)
0 ft. 58 ft. Dirt
5-29-2024 56 ft• 165 ft Rock
4.Date Well(s)Completed: Well ID# s
ft. ft. �. - , ' / 1,� �•,/
5a.Well Location: `.r��
Richard Cuchiera
AUG a 9 2024
Facility/Owner Name Facility ID#(if applicable) ft. ft.
1305 Auton Rd Lenoir NC 28645 ft. ft. Ir,•.,;.,,.4••., _-r_yctz;-g Unit
Physical Address,City,and Zip ft. ft.
Caldwell 21.REMARKS
County Parcel Identification No.(PIN)
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(if well field,one lat/long is sufficient) 22.Certification:
35.971.61' N 81.486.52' W
C-1.1-ea: 6/20/2024
6.Is(are)the well(s): OPermanent or 11Temporaryore of Certified W I Contractor Date
By signing this form,I hereby certiff,that the well(s)was(were)constructed in accordance with
7.Is this a repair to an existing well: 0 Yes or ONo ISA NCAC 02C.0100 or ISA NCAC 02C.0200 Well Construction Standards and that a copy
If this is a repair,fill out known well construction information and explain the nature of the of this record has been provided to the well owner.
repair under#21 remarks section or on the back of this form.
23.Site diagram or additional well details:
8.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page to provide additional well construction info
construction,only 1 GW-1 is needed. Indicate TOTAL NUMBER of wells (add'See Over'in Remarks Box).You may also attach additional pages if necessary.
drilled: 24.SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 165 (ft•) Submit this GW-1 within 30 days of well completion per the following:
For multiple wells list all depths ifdifferent(example-3(i200'and 2@100)
80 24a. For All Wells: Original form to Division of Water Resources (DWR),
10.Static water level below top of casing: (ft-) Information Processing Unit,1617 MSC,Raleigh,NC 27699-1617
If water level is above casing,use••+"
11.Borehole diameter: 6.25 (in.) 24b.For Injection Wells:Copy to DWR,Underground Injection Control(IUC)
Program,1636 MSC,Raleigh,NC 27699-1636
12.Well construction method: Air Drilled
24c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the
(i.e.auger,rotary,cable,direct push,etc.) county environmental health department of the county where installed
FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producing over 100,000 GPD:Copy to DWR,CCPCUA
20 Air Permit Program,1611 MSC,Raleigh,NC 27699-1611
13a.Yield(gpm) Method of test:
13b.Disinfection type: HTC Amount: 1/3 cup
Form GW-1 North Carolina Department of Environmental Quality-Division of Water Resources Revised 6-6-2018