Loading...
HomeMy WebLinkAboutSW6231002_Supplement-EZ Form_20240805 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 'Project Name Serenity-Phases 8&9 2 Project Area(ac) 155.11 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 1.5 5 Is this project High or Low Density? Both High and Low Density 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) _ 30(intermittent streams)&100(perennial streams) 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? _ N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 !Infiltration System 12 Bioretention Cell 13 Wet Pond 6 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 17 Rainwater Harvesting(RWH) 18 Green Roof 19 Level Spreader-Filter Strip(LS-FS) 20 Disconnected Impervious Surface(DIS) 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Bayfilter 26 Filterra 2 FORMS LOADED DESIGNER CERTIFICATION 27 'Name and Title: Brandon Miller,PE-Project Manager 28 Organization: WithersRavenel,Inc. 29 Street address: 115 MacKenan Drive 30 City,State,Zip: Cary,NC 27511 31 Phone number(s): 919.469.3340 32 Email: bmiller@withersravenel.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. DocuSigned by: Designer °p00000000000000 ,—DocuSigned by: br'Atn,h1A, hair r °°FESS/p°!/'L°°° o Z o°�o v o'9 0 '-QEs DCQC5FACaoC Q SEAL Signature of Designer 049066 vGINE,,Q^"QQ 7/2/2024 NJ Seal Date 7/2/2024 Serenity-Phases 8 9 DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 8 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 3 4 Type of SCM Wet Pond(SCM 6) Wet Pond(SCM 7) Wet Pond(SCM 8) 5 Total drainage area(sq ft) 6,691,205 515,017 1,098,629 388,130 6 Onsite drainage area(sq ft) 6,691,205 515,017 1,098,629 388,130 _ 7 Offsite drainage area(sq ft) 0 0 0 0 8 Total BUA in project(sq ft) 2,350,384 271,228 550,820 191,558 New BUA on subdivided lots(subject to permitting) 9 (sq ft) 1,470,050 171,200 347,983 129,425 New BUA not on subdivided lots(subject to 10 permitting)(sf) 880,334 100,028 202,837 62,133 11 Offsite BUA(sq ft) 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) -Sidewalk(sq ft) 164,472 19,090 40,794 8,891 -Roof(sq ft) -Roadway(sq ft) 543,724 60,938 132,043 28,242 -Future(sq ft) -Other,please specify in the comment box below(sq ft) 172,137 20,000 30,000 25,000 New infiltrating permeable pavement on 13 subdivided lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to 15 permitting)(sq ft) 16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sq ft) 18 Percent BUA 35% 53% 50% 49% 19 Design storm(inches) 1.0 in 1.0 in 1.0 in 20 Design volume of SCM(cu ft) 35894 cf 76772 cf 23863 cf 21 Calculation method for design volume Simple Simple Simple �L INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): OTHER'BUA ALLOTED TO PARKS/AMENITIES.AN ADDITIONAL 3,637-SF OF BUA IS ALLOTTED TO THE PUMP STATION IN THE SCM 11 DRAINAGE AREA'OTHER' Drainage Areas 7/2/2024 Serenity-Phases 8 9 DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 8 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 4 I 5 6 Wet Pond(SCM 4 Type of SCM Wet Pond(SCM 9) Wet Pond SCM 10) 11) 5 Total drainage area(sq ft) 6,691,205 681,171 I 805,662 511,235 6 Onsite drainage area(sq ft) 6,691,205 681,171 805,662 511,235 7 Offsite drainage area(sq ft) 0 0 0 0 8 Total BUA in project(sq ft) 2,350,384 354,051 434,718 284,790 New BUA on subdivided lots(subject to permitting) 9 (sq ft) 1,470,050 216,875 255,475 145,400 New BUA not on subdivided lots(subject to 10 permitting)(sf) 880,334 137,176 179,243 139,390 _ 11 Offsite BUA(sq ft) 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) -Sidewalk(sq ft) 164,472 26,731 31,630 24,337 -Roof(sq ft) -Roadway(sq ft) 543,724 90,444 102,613 82,916 -Future(sq ft) -Other,please specify in the comment box below(sq ft) 172,137 20,000 45,000 32,137 New infiltrating permeable pavement on 13 subdivided lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to 15 permitting)(sq ft) 16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sq ft) 18 Percent BUA 35% 52% 54% 56% 19 Design storm(inches) 1.0 in 1.0 in 1.0 in 20 Design volume of SCM(cu ft) 42145 cf 44087 cf 25214 cf 21 Calculation method for design volume Simple Simple Simple �L INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): OTHER'BUA ALLOTED TO PARKS/AMENITIES.AN ADDITIONAL 3,637-SF OF BUA IS ALLOTTED TO THE PUMP STATION IN THE SCM 11 DRAINAGE AREA'OTHER' Drainage Areas 7/2/2024 Serenity-Phases 8 9 DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so,number of drainage areas/SCMs 8 3 Does this project have low density areas? Yes 4 If so,number of low density drainage areas 1 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 7 8 LD 1 4 Type of SCM Filterra(SCM 12) Filterra(SCM 13) Low Density 5 Total drainage area(sq ft) 6,691,205 61,892 63008 2566461.003 6 Onsite drainage area(sq ft) 6,691,205 61,892 63,008 2566461.003 7 Offsite drainage area(sq ft) 0 0 0 0 8 Total BUA in project(sq ft) 2,350,384 40,541 40521 sf 182157 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) 1,470,050 14,550 9333 sf 179808 sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 880,334 25,991 31,188 2,349 11 Offsite BUA(sq ft) 12 Breakdown of new BUA not on subdivided lots: -Parking(sq ft) -Sidewalk(sq ft) 164,472 5,935 6270 sf 795 sf -Roof(sq ft) -Roadway(sq ft) 543,724 20,057 24918 sf 1553 sf -Future(sq ft) -Other,please specify in the comment box below(sq ft) 172,137 New infiltrating permeable pavement on 13 subdivided lots(sq ft) New infiltrating permeable pavement not on 14 subdivided lots(sq ft) Existing BUA that will remain(not subject to 15 permitting)(sq ft) 16 Existing BUA that is already permitted(sq ft) 17 Existing BUA that will be removed(sq ft) 18 Percent BUA 35% 66% 64% 7% 19 Design storm(inches) 1.0 in 1.0 in N/A 20 Design volume of SCM(cu ft) N/A N/A N/A 21 Calculation method for design volume Simple Simple N/A �L INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): OTHER'BUA ALLOTED TO PARKS/AMENITIES.AN ADDITIONAL 3,637-SF OF BUA IS ALLOTTED TO THE PUMP STATION IN THE SCM 11 DRAINAGE AREA'OTHER' Drainage Areas 7/2/2024 Serenity-Phases 8 9 WET POND 1 Drainage area number SCM 6 I SCM 7 I SCM 8 I SCM 9 I SCM 10 I SCM 11 2 Minimum required treatment volume(Cu ft 22499 cf 45905 cf 15992 cf 29399 cf 35962 cf 23551 cf FERAL MDC FROM 02H.1050 �_ 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes Yes Yes Yes Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes Yes Yes Yes Yes 5 What are the side slopes of the SCM(H:V)? 3:1 3:1 3:1 3:1 3:1 3:1 6 Does the SCM have retaining walls,gabion walls or other engineered No No No No No No side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes Yes Yes Yes Yes Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes Yes Yes Yes Yes Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice Drawdown Orifice Drawdown Orifice Drawdown Orifice Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? Yes _ Yes Yes _ Yes Yes Yes 11 Does the maintenance access comply with General MDC(8)? Yes Yes Yes Yes Yes Yes 12 Does the drainage easement comply with General MDC(9)? Yes Yes Yes Yes Yes Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with N/A N/A N/A N/A N/A N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes Yes Yes Yes Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes Yes Yes Yes Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes Yes Yes Yes Yes 17 Was the SCM designed by an NC licensed rofessional? Yes Yes Yes Yes Yes Yes WET POND MDC FROM 02H.1053 18 Sizing method used SA/DA SA/DA SA/DA SA/DA SA/DA SA/DA 19 Has a stage/storage table been provided in the calculations? Yes Yes Yes Yes Yes Yes 20 Elevation of the excavated main pool depth(bottom of sediment 327.00 324.00 348.00 358.00 366.00 372.00 removal)(fmsl) 21 Elevation of the main pool bottom(top of sediment removal)(fmsl) 328.00 325.00 349.00 359.00 367.00 373.00 22 Elevation of the bottom of the vegetated shelf(fmsl) 332.00 328.00 352.00 362.00 370.00 376.00 23 Elevation of the permanent pool(fmsl) 332.50 328.50 352.50 362.50 370.50 375.50 24 Elevation of the top of the vegetated shelf(fmsl) 333.00 329.00 353.00 363.00 371.00 377.00 25 Elevation of the temporary pool(fmsl) 335.00 331.00 354.00 364.50 372.25 377.50 26 Surface area of the main permanent pool(square feet) 8931 21078 10655 14685 18135 8122 27 Volume of the main permanent pool(cubic feet) 30626 cf 62985 cf 29923 cf 42374 cf 53625 cf 31450 cf 28 Average depth of the main pool(feet) 3.50 ft 3.00 ft 3.00 ft 3.00 ft 3.00 ft 3.00 ft 29 Average depth equation used Equation 3 Equation 3 Equation 3 Equation 3 Equation 3 Equation 3 30 If using equation 3,main pool perimeter(feet) 420.0 ft 669.0 ft 413.0 ft 520.0 ft 600.0 ft 465.0 ft 31 If using equation 3,width of submerged veg.shelf(feet) 3.0 ft 3.0 ft 3.0 ft 3.0 ft 3.0 ft 3.0 ft 32 Volume of the forebay(cubic feet) 6059 cf 9977 cf 5294 cf 8499 cf 9733 cf 4814 cf 33 Is this 15-20%of the volume in the main pool? Yes Yes Yes Yes Yes Yes 34 Clean-out depth for forebay(inches) 12 in 12 in 12 in 12 in 12 in 12 in 35 Design volume of SCM(cu ft) 35894 cf _ 76772 cf 23863 cf _ 42145 cf _ 44087 cf 25214 cf _ 36 Is the outlet an orifice or a weir? Orifice Orifice Orifice Orifice Orifice Orifice 37 If orifice,orifice diameter(inches) 2.50 in _ 2.75 in 2.00 in _ 3.00 in _ 3.25 in _ 2.50 in _ 38 If weir,weir height(inches) 39 If weir,weir length(inches) _ 40 Drawdown time for the temporary pool(days) 2.8 4.9 4.5 2.5 2.4 2.2 41 Are the inlet(s)and outlet located in a manner that avoids short- Yes Yes Yes Yes Yes Yes circuiting? 42 Are berms or baffles provided to improve the flow path? No Yes No No No No _ 43 Depth of forebay at entrance(inches) 54 in 54 in 54 in 54 in 54 in 54 in 44 Depth of forebay at exit(inches) _ 36 in _ 12 in 12 in - 12 in 12 in _ 12 in _ 45 Does water flow out of the forebay in a non-erosive manner? Yes Yes Yes Yes Yes Yes 46 Width of the vegetated shelf(feet) 6 ft _ 6 ft 6 ft - 6 ft 6 ft _ 6 ft _ 47 Slope of vegetated shelf(H:V) 6:1 6:1 6:1 6:1 6:1 6:1 48 Does the orifice drawdown from below the top surface of the Yes Yes Yes Yes Yes Yes permanent pool? 49 Does the pond minimize impacts to the receiving channel from the 1- Yes Yes Yes Yes Yes Yes yr,24-hr storm? 50 Are fountains proposed?(If Y,please provide documentation that No No No No No No MDC(9)is met.) 51 Is a trash rack or other device provided to protect the outlet system? Yes Yes Yes Yes Yes Yes 52 Are the dam and embankment planted in non-clumping turf grass? Yes Yes Yes Yes Yes Yes 53 Species of turf that will be used on the dam and embankment Centipede Centipede Centipede Centipede Centipede Centipede 54 Has a planting plan been provided for the vegetated shelf? Yes Yes Yes Yes Yes Yes ADDITIONAL INFORMATION 55 Please use this space to provide any additional information about the wet pond(s): 2 LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances(H:V) 3 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s)(%) 8 Bottom width of curb outlet swale(s)(feet) 9 Maximum side slope of curb outlet swale(s)(H:V) 10 Minimum length of curb outlet swale(s)(feet) 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule.1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: Drainage Pervious Swale Area BUA area C Q Slope V,iiow V., Flow depth (ac) (ac) (acl (cfs) (%) (fps) (fps) (ft) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 2 FILTERRA BIORETENTION I1 Drainage area number SCM 12 SCM 13 2 Minimum required treatment volume(Cu ft) 1828 2448 GENERAL MDC FROM 02H.1050 .3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes Yes 4 Is the SCM located away from contaminated soils? No No 5 What are the side slopes of the SCM(H:V)? 6 Does the SCM have retaining walls,gabion walls or other engineered side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes Yes (10-year storm)? 8 Is there an overflow or bypass for inflow volume in excess of the Yes Yes design volume? 9 What is the method for dewatering the SCM for maintenance? 10 If applicable,will the SCM be cleaned out after construction? Yes Yes 11 Does the maintenance access comply with General MDC(8)? Yes Yes 12 Does the drainage easement comply with General MDC(9)? Yes Yes 13 If the SCM is on a single family lot,does(will?)the plat comply with N/A N/A General MDC(10)? 14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes 17 Was the SCM designed by an NC licensed professional? Yes Yes FILTERRA BIORETENTION MDC FROM THE STORMWATER DESIGN MANUAL 18 Type of pretreatment that will be used Dissipater Dissipater 19 Depth of storage above the filter media surface(in) 12 in 12 in 20 Surface area of the Filterra Bioretention system(sq ft) 89 sf 120 sf 21 Method of flow distribution over the media Dispersed Dispersed 22 Infiltration rate of engineered media(inch/hour) 2 in/hr 2 in/hr 23 Diameter of the underdrain pipes(if applicable) 6 in 6 in 24 Does the design include Internal Water Storage(IWS)? No No 25 if so,elevation of the top of the IWS(fmsl) N/A N/A 26 Elevation of the planting surface(fmsl) 379.5 318 27 Species of tree(s)that will be planted None None 28 Media depth(inches) 30 in 30 in 29 Number of clean out pipes 1 1 30 Will maintenance be performed per the Filterra Operations and Yes Yes Maintenance Manual? ADDITIONAL INFORMATION Please use this space to provide any additional information about the 31 Filterra Unit(s): 2