Loading...
HomeMy WebLinkAbout310033_Application Attachment - Drawings Digester System_20240806DU LIN COUNTY, NORTH CAROLINA ADDRESS 593 PAUL ED DAIL RD, KENANSVILLE,NC GNPP�� �O LEGEND. �G N 90aso RW = RAINWATER O CIVIL ENGINEER O< 10R SGHOOL Rp. = GAS LINE .pO _ FPRR MCCLU RE LS = LIFT STATION ywY 24 2001 W. BROADWAY COLUMBIA MO 65203 T = UNDERGROUND TELEPHONE 573-814-1568 OHE- = OVERHEAD ELECTRICAL sT = STORM DRAIN WTL- = WATER TRANSFER LINE DFL FARM #1 ELECTRICAL ENGINEER - Go - = GRAVITY OVERFLOW DFL FARM #2 ROESLEIN &ASSOCIATES, �o 9200 WATSON ROAD SUITE 200 = PROPERTY LINE '1/4 Rp ST. LOU IS, MO 63126 = SET BACK LIMITATIONS (314) 729-0055 1.500 = OCCUPIED RESIDENCES SET BACK N 2.500 = CHURCH & SCHOOL SET BACK . 1-1/0< SHEET INDEX = TRUE NORTH �`/04 � DIGESTER OPTIONS COUNTY MAP `S<� RA270-00-27021-1 - COVER & SHEET INDEX = EXISTING POWER POLE O RA270-00-27021-2 -AREA 1000 NEW DIGESTER GRADING = CONCRETE BARRIER RA270-00-27021-3 -AREA 1000 DFL FARM 1 & 2 SITE LAYOUT � ! sp Oo50� RA270-00-27021-4 -AREA 1000 NEW DIGESTER LAYOUT = EXISTING SEWER MODIFICATION CO 0 RA270-00-27021-5 - AREA 1000 HYDRAULIC PROFILE = DATA FROM FISH & WILDLIFE RA270-00-27021-6 -AREA 1000 EROSION CONTROL NATIONAL WETLANDS = 100' WET WELL SETBACK VICINITY MAP Detail Drawing Control Index N LEGEND: TRUE NORTH = DUPLIN COUNTY Sys. Sys. Description Drawing DWG Description General Drawings RA-STD-251 Typical Lagoon Operating Levels RA-STD-253 Anchor Trench Installation RA-STD-270 Liner Penetration Installation S-1 Digester Influent RA-STD-269 Forced Sewer RA-STD-280 Lift Station Pump Piping RA-STD-285 Precast Lift Station S-2 Digester Effluent RA-STD-263 Floating Pump Discharge RA-STD-295 ART System Connection S-3 Wet Well RA-STD-262 Wet Well Installation RA-STD-274 Wet Well Level Indicator S-4 Cover/Rain Water RA-STD-256 Rainwater Removal Suction Pipe RA-STD-271 Rainwater Removal Pump S-5 Mixing RA-STD-289 Typical Lagoon Mixing System S-6 Power Flush RA-STD-266 Power Flush RA-STD-282 Wet Well Power Flush S-7 Sludge Removal RA-STD-264 Irrigation Suction S-8 Digester Vent RA-STD-255 Lagoon Vent Ports S-9 GCS Interface RA-STD-261 Biogas Draw -Off RA-STD-267 Off -Spec Connection RA-STD-288 Condensate Return HARY STEWART 7/10/2024 9:08:42 AM C:\VAULT\PROJECTS\MONARCH B10 ENERGY\REGISTER, NC\CADD\01 RA270\ORTHOS\DWGS\00 GENERAL ARRANGEMENTS\RA270-00-27021.DWG GENERAL NOTES: 1. THE QUANTITIES SHOWN ON THIS PLAN ARE BASED ON ENGINEER'S CALCULATIONS REQUIRED TO ACHIEVE THE DESIRED GRADES. 2. VERIFY LOCATION OF ALL UTILITIES (BOTH ABOVE AND BELOW GROUND) PRIOR TO ANY EXCAVATION. CALL 811 PRIOR TO ANY EXCAVATION ACTIVITIES. 3. EROSION PROTECTION SHALL BE INSTALLED AT INLET LOCATIONS. 4. TOPSOIL STRIPPED FROM THE LAGOON SITE SHALL BE STOCKPILED ON -SITE FOR COVERING THE OUTSIDE OF THE BERMS. 5. EMBANKMENT MATERIALS SHALL BE FREE OF SOD, ROOTS, AND OTHER OBJECTIONALBLE MATERIALS. 6. ALL ELEVATIONS SHALL BE AT GRADE OR PLUS 0.1' OF DESIGN GRADE. 7. BERM FILL FOR THE PROPOSED LAGOON DIGESTER TO BE PLACED IN 6" LIFTS TO 95% OF STANDARD PROCTOR AT -1 % TO +3% OF OPTIMUM MOISTURE. 8. EACH 6" LIFT SHALL BE TESTED FOR MOISTURE/DENSITY BY A QUALIFIED GEOTECHNICAL LABORATORY APPROVED BY ENGINEER. A FAILING TEST REQUIRES REWORK OF AREA TO MEET SPECIFICATION. 9. THE INTERFACE SURFACE OF SUCCESSIVE LAYERS IS TO BE DISKED OR SCARIFIED PRIOR TO PLACEMENT OF SUBSEQUENT LAYERS OF CLAY. 10. ALL INSIDE AND OUTSIDE CUTS/FILLS ARE 3:1 UNLESS OTHERWISE NOTED. 11. NO OFF -SITE MATERIAL MAY BE IMPORTED FOR LAGOON LINING UNLESS APPROVED BY THE ENGINEER. 12. LAGOON TO BE LINED WITH 60-MIL THICK HDPE SYNTHETIC LINER. THE INSIDE WALLS OF THE LAGOON SHALL BE SMOOTH ROLLED PRIOR TO LINER INSTALLATION. 13. PROVIDE PROPER CONSTRUCTION AND WORKMANSHIP TO ENSURE NECESSARY SLOPES FOR DRAINAGE. Cut/Fill Summary Name Cut Factor Fill Factor 2d Area Cut Fill Net QTY-27021 DFL 1.000 1.200 125969.44 Sq. Ft. 11764.41 Cu. Yd. 11517.32 Cu. Yd. 247.09 Cu. Yd.<Cut> Totals 125969.44 Sq. Ft. 11764.41 Cu. Yd. 11517.32 Cu. Yd. 247.09 Cu. Yd.<Cut> CHAMILTON 7/2/2024 9:15:38 AM R:\200599\06-DRAWINGS\CIVIL\A1K\REGISTER-CLUSTER 1\AFO PERMIT DRAWINGS\27021 DFL AFO PERMIT.DWG a o p 0 p a O � o d I , a0 0 0 a O -16 O 8p,19=78=77 FF:83.5 1 80 4 PIT:83.0 p 4 e o �✓v o 4 0 EX BARN FF:83.5 ° PIT:83.0 EX BARN p p a FF..83•5 EX LAGOON \ ° 0110 (27521) EX BARN F F 83.5 PIT:83.0 O o Q o EX BARN a FF.B3.5 \ PIT:83.0 � \� o ° 0 0 � EX ARN rJ Q 4 o FF:83.5 PIT.83.0 a e o q EX BARN D C FF:83.5 0 �o P. Q Q I 0 o M PIT:83.0 � N� • 4 a o c Q D D o °•b a 4 .o o a 40 a � d v p 0 O o ° o o Dad a o b• a � C7 CO r� a d o a D a ► b C� C3 ° o C` Q 4j a 7 - . a � v b ° q f `� Q e Q • 0 �/� p r� a O 0 as �° �•� d83 + • D � CO 82 Cc p � 0 FF:83.75 CS v EX BARN SS o � FF:83.75 o v PIT:83.0 �o / P, � EX BARN EX LAGOON �9 �� a o. FF:83.75 (27522) cc aQ o a v p rF X BARN co aF83.75 �a PIT:83.0 83 � � � Q EX BARN f o Q a o FF:83.75 h d o o PIT:83.0 Q Q Q o /! 82 EXBAR5 oA� 73, p° i F F:83.7 0 o PIT„1 A � 87 _ 79�80 72 6 0 � o O /80 �79�'-73.74 Q o �Q Q D p Jg 80�79 7A 0 0 �7068.40 0 o I� 00 69� �� FLOOR a � e ^NEW a o 0 >> DIGESTER 80.40 69 a D P o 6 70 TOP OF BERM 71 0 76 74�73= p '76�75 ,e 73�h 71 1_4_4i L� I F A PROPERTY OWNER DAIL FARMS LIVESTOCK, LLC PROPERTY OWNERS DAIL HENERY GIBSON A� PROPERTY OWNERS DAIL HENERY GIBSON mmqr� F 4� r Iv ■ram pG P� A P/ Pt PROPERTY OWNER \� <- PROPERTY OWNERS - DAIL, HENRY GIBSON PL _ PROPERTY OWNERS TC&I TIMBER COMPANY, LLC C/O THE CAMPBELL DAIL FARMS �< GROUP LLC. - Pt LIVESTOCK, LLC - PL I A a PL / 0000\ 1.500 1.500 A 50° 1, s ` - 1.50 1.500 l.S°0 °° ,�� D F L 1 - i 5°° � , FA w / A _ - s°° 1.500 PL ---- PROPERTY OWNER HALL, MARGARET E. P� PROPERTY OWNERS P� e DAIL FARMS 0000 p p r -- \A LIVESTOCK, LLC so ` ,�1500' SETBACK S0O PROPERTY OWNER Q, _ MOORE, HENRY LEWIS HRS, r r - z - ETAL C/O JOSEPH MOORE / o PL -SETBACK LIMITATIONS QWT`� PROPERTY OWNERS - _ALad P� P� PL r DAIL FARMS Ir a1 Ap±� i LIVESTOCK, LLC P.W PROPERTY LINE (TYP.) 1. 27522 - DFL 2 T � Pt 1 FARM ,=,--, PROPERTY OWNER so PROPERTY OWNERS •� � N� � f -�.- • DAIL PAUL HENRY & DAIL JODIE ELIZABETH PROPERTY OWNERS DAIL FARMS DAIL FARMS / PROPERTY OWNERS DAIL \ LIVESTOCK LLC FARMS LIVESTOCK LLC 1' — PL PL �� PROPERTY OWNER so LIVESTOCK, LLC T PL — PL soo .soo �! DAIL, PAUL HENRY & DAIL JODIE ELIZABETH \ _ r PROPERTY OWNER `� PROPERTY OWNER MOORE, MARGUERITE � o° N. ' PL PL DAIL, PAUL HENRY & DAIL JODIE ELIZABETH a J vlL 1150' RESIDENTIAL '' PL PL � PL PL - n � 9�05 15°° _ SET BACK (TYP.) - PROPERTY OWNER 00 —1�o00 5b�00� �� I PL PL PL DAIL, PAUL HENRY & DAIL JODIE ELIZABETH —�.50 PROPERTY OWNERS--- PROPERTY OWNER - DAIL FARMS PL � PL � PL DAIL, PAUL HENRY & DAIL JODIE ELIZABETH QA PROPERTY OWNERS LIVESTOCK, LLC �/,,,■� r DAIL FARMS --- - -- --- LIVESTOCK, LLC PL � PL PROPERTY OWNER DAIL, PAUL HENRY & DAIL JODIE ELIZABETH _ 100 ROAD SETBACK A� PL TRUE NORTH r waft tJ r -JF ♦= F • 1 ZACHARY STEWART 7/10/2024 9:08:44 AM C:\VAULT\PROJECTS\MONARCH B10 ENERGY\REGISTER NC\CADD\01 RA270\ORTHOS\DWGS\00 GENERAL ARRANGEMENTS\RA270-00-27021.DWG IRRIGATION PIVOT IRRIGATION PIVOT BSEWER INFLUENT MODIFICATIONNEEDED - 78.000 BARN 7g.000 o00 82.0' 6o .000 BARN 2 83•01 D F L 1 * FARM 4111 3 83.0' > I BARN 4 (S-1) RA-STD-285 83.0' !S 27521 G BARN 5� 82,01 BARN 6� 82.0' ---- I BARN 7 N 82.0' BARN 8 1 o 0) o �082.0� 0 0 -- CD °�° 00 Lo Co o a2oo �� i oe000l* 77.00 r� o° 0 r N -1 r (S-1) RA-STD-280 11 WATER TRANSFER LINE N� r a N� I 1 1 wry WrL BARN RECYCLE 83.0' I� PUMP NI BARN 2 rI 830' I0 NI BARN 3 83 0' 27522 GRAVITY TRANSFER I - - - �•�! r BARN 4 rI - 83.0'------- ------------- _ I° �I DFL 2 I FARM BARN 5 I CD82.00 N 83.0l m Go --------- I" 0 (S-8) RA-STD-2664_/ BARN 6 - 83.0' o GO I us SGO GG � � 6 SEWER INFLUENT LINE Go lS 5 MODIFICATION NEEDED 10 1 � I _ R_C\ RA -STD- 66 1 85.00 RAIN WATER LINE S-4 RA-STD-277 & RA-STD-289 ji (S-5) RA-STD-289 AREA 1000 DFL1 & DFL2 FARM ZACHARY STEWART 7/10/2024 10:50:59 AM C:\VAULT\PROJECTS\MONARCH BIO ENERGY\REGISTER, NC\CADD\01 RA270\ORTHOS\DWGS\00 GENERAL ARRANGEMENTS\RA270-00-27021.DWG 75.00 r-q L,J (S-2) RA-STD-295 F o� F1 WATER TRANSFER LINE TEMPORARY FLARE MIN. 50' AWAY FROM f - EDGE OF DIGESTER RAN WATER LINE S-4 RA-STD-277 (S-4) RA-STD-28° (S-9) RA-STD-26' (S-9) RA-STD-26, (S-7) RA-STD-264 on LAGOON 270Z-1 D-1 27021 LOCATION DETAIL off'" r kA s 00 �11111IIIIIII I HEREBY CERTIFY THAT THISCAR ENGINEERING DOCUMENTWAS O��'� .•••••• •. I ��� �..••• =±0.5° REV # DATE REVISION DESCRIPTION DRWN BY CHK'D BY APP'D BY FRACTIONS: INCHES: THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC AND IS PROTECTED UNDER STATE AND FEDERAL LAW, INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et seq. ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC RESERVES ALL PATENT, COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN MANUFACTURING REPRODUCTION USE AND SALES RIGHTS THERETO EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC. ANY USE OF THE INFORMATION — MACHINED PARTS =±1/64 HOLE LOCATIONS ON =±1/32 WELDED ASSEMBLIES LINEAR DIMENSIONS ON =±1 /16 STRUCTURAL WELDMENTS .X =±.020 .XX =±.090 .XXX =±.005 XXXX=±.0002 ANGLES =±.05° CONTAINED IN THIS DOCUMENT OTHER THAN BY THE AUTHORIZED RECIPIENT FOR THE EXPRESS PURPOSE FOR WHICH IT HAS BEEN ANGLES - -±1° PROVIDED IS STRICTLY PROHIBITED. UPON THE REQUEST OF ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC 4 THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIES THEREOF IN ITS POSSESSION. ©2023 ROESLEIN & ASSOCIATES, INC. AND ROESLEIN ALTERNATIVE ENERGY, LLC DO NOT SCALE PRINT MONARCH BIO ENEGRY REGISTER, NC AREA 1000 DFL1 FARM & DFL2 FARM NEW DIGESTER LAYOUT ENGINEERS • MANUFACTURERS • CONSTRUCTORS DWG. SHEET REV NO. O.RA270-00-27021 30F6 D 120 110 100 70 NORTH BARNS LIFT STATION (SEE DETAIL) FF:85.5 ( ) FF:85.5 ( ) FF:85.5 ( ) FF:85.5 ( ) FF:85.5 ( ) FF:85.5 ( ) FF:85.5 ( ) FF:85.5 ( ) FF:83.00 FF:83.00 FF:83.00 FF:83.00 FF:83.00 FF:83.00 FF:83.00 FF:83.00 RIM: 83.50 NOTE: INVERTS OF EXISTING GRAVITY PIPING ARE APPROXIMATED BASED ON BEST AVAILABLE SURVEY INFORMATION. BOTTOM: 73.50 LEGEND: TOB: TOP OF BANK ELEVATION SOUTH BARNS FF:(83.75) FF:(83.75) FF:(83.75) FF:(83.75) FF:(83.75) FF:(83.75) FF:83.00 FF:83.00 FF:83.00 FF:83.00 FF:83.00 FF:83.00 FF: FINISHED FLOOR ELEVATION FB: FREEBOARD ELEVATION EG: EXISTING GRADE ELEVATION OL: OPERATING LEVEL ELEVATION INV: INVERT ELEVATION SHWT: SEASONAL HIGH WATER TABLE LIQUID FLOW DIRECTION RIM: 81.40 12" MIN ABOVE EX TOB: 80.40 HDPE COVER MIXING STATION GRADE (SEE DETAIL) PROPOSED DIGESTER - ----- - OL:78.40 DRY WELL - INV: 77.40 BOTTOM: 73.40 INV: 70.40 BOTTOM: 68.40 RIM: 81.40 12" MIN ABOVE EX 1 GRADE BOTTOM: 73.40 FLOATING EXISTING PUMP LAGOON FB:81.00 (27522) TOB: 82.00 WATER TRANSFER EXISTING LAGOON FB:79.50 (27521) TOP OF TEMP STORAGE: 78.80 BOTTOM:70.50 / TOB: 80.50 �SHWT: 75.00 120 ow m m 70 m CHAMILTON 7/2/2024 9:15:51 AM R:\200599\06-DRAWINGS\CIVIL\A1 K\REGISTER-CLUSTER 1\AFO PERMIT DRAWINGS\27021 DFL AFO PERMIT.DWG CHAMILTON 7/2/2024 9:15:58 AM R:\200599\06-DRAWINGS\CIVIL\A1K\REGISTER-CLUSTER 1\AFO PERMIT DRAWINGS\27021 DFL AFO PERMIT.DWG TOP OF BERM HIGH PUMP OPERATING HEIGHT 0 N l 1 12" WET WELL LATERAL LAGOON OPERATING LEVELS SPIROS1623 3/5/2024 4:16:25 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\NC - GENERAL\RA-STD-251-2.DWG II[GANTIlIl►VAI?i WET WELL LATERAL CENTER OF PIPE TOP OF SLUDGE BOTTOM OF LAGOON ninTP-- 1. PERIMETER PIPING. SEE RA-STD-254 FOR DETAILS. 2. NO TRENCH; EXCAVATE FROM TURNDOWN OF LINER/COVER; BACK FILL AND COMPACT IN STAGES TO COVER LINER/COVER. NOTES: DAYLIGHT OUT BERM LAGOON EMERGENCY VENT PORT ELEVATION VIEW 2 1. TWO EMERGENCY VENTS REQUIRED PER LAGOON, ONE AT EACH END OF THE LAGOON FURTHEST FROM THE BARNS. NOTES: NnTF.q- SSPIROS1623 HIGH EFFLUENT LOW EFFLUENT DETAIL A: BIOGAS EXTRACTION POINT SECTION VIEW 3 BILL OF MATERIALS TAG DESCRIPTION SPEC SIZE QTY 1 PIPE HP01 811 VARIES 2 PIPE HP01 411 20' 3 90 ELBOW HP01 8" 1 4 ECCENTRIC REDUCER HP01 8" x 4" 1 5 TEE HP01 8" 2 6 FLANGE ADAPTER HP01 8" 1 7 BACKUP RING HP01 811 1 8 MACHINE BOLT HP01 3/4" x 3" 8 9 BUTTERFLY VALVE BUF05 811 1 10 22.5 ELBOW HP01 411 1 11CA1/�� �' `��� ASSOCIATES, INC.COPIES , THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL RA-STD-2 61-1 1 OF 1 3 /06/2' IN ITS POSSESSION. ©20 9ROESLEIIN&ASSOCIIATES,INC. DO NOT SCALE PRINT NO. NnTF.q- OPERATING WATER LEVEL SSPIROS1623 6/25/2024 1:50:41 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-262-3.DWG 3 AIf1TrC%. 6PIROS1623 3/7/2024 10:38:30 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-264-2.DWG il."I'I Lfil KinTF.q- - � NOTE 4 1 BILL OF MATERIALS TAG DESCRIPTION SPEC SIZE QTY 1 PIPE FLANGE ADAPTER HP02 6" 609 2 HP02 6" 1 3 BACKUP RING HP02 6" 1 4 GASKET STUD BOLTS W/ NUTS HP02 6" 1 8 5 HP02 3/4" x 4%4" LG 6 BLIND FLANGE HP02 6" 1 ROESLEIN & ASSOCIATES, INC. RNG PIPING STANDARD ROESLEIN. AREA 1000 POWER FLUSH ENGINEERS • MANUFACTURERS • CONSTRUCTORS INSTALLATION DETAILS DWG. SHEET REV NO. RA-STD-266 1 OF2 1 3 REDUCER, ECCENTRIC HP01 8" x 4" 1 4 90 ELBOW HP01 811 5 5 BUTTERFLY VALVE BUF05 811 1 6 FLANGE ADAPTER HP01 811 2 7 BACKUP RING HP01 811 2 8 MACHINE BOLT HP01 3j4° x 3° 16 ROESLEIN & ASSOCIATES, INC. RNG PIPING STANDARD ROESLEIN. AREA 1000 OFF -SPEC CONNECTION ENGINEERS • MANUFACTURERS • CONSTRUCTORS INSTALLATION DETAILS DWG. SHEET REV NO. RA -STD -267 1 OF2 1 NOTFS- HIGH PUMP SPIROS1623 4/11/2024 2:46:45 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-269.DWG KinTF.q- CS05 3" x 12" 1 CS05 3" x 8" 2 CS05 3" 1 CS05 3" 2 S P-1008A-XX 3" 1 H P02 5/8" X 13/4" 24 CS05 OUTLET %2", HEADER 3/4" 1 CS05 j2" x 4" 1 CS05 %2" 1 H P02 3" 4 ENGINEERS • MANUFACTURERS • CONSTRUCTORS DWG. G . SHEET REV NO. RA -STD -271-3 1 OF 1 FRONT VIEW NOTES: V SPIROS1623 6/25/2024 2:19:20 PM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-274-2.DWG 56059Go NOTES: NOTES: SPIROS1623 6/26/2024 9:56:24 AM ...... 8 06/ 111111����`` Ed REV DATE REVISION DESCRIPTION UKWN (HK'U APP'L # BY BY BY BY THIS DOCUMENT, ALONG WITH ITS DESIGNS, KNOW-HOW AND DRAWINGS, CONTAINS CONFIDENTIAL AND PROPRIETARY — INFORMATION THAT IS THE PROPERTY OF ROESLEIN & ASSOCIATES, INC. AND IS PROTECTED UNDER STATE AND FEDERAL LAW, INCLUDING 18 USC SECTION 1836 AND 17 USC SECTION 101 et se . ROESLEIN &ASSOCIATES INC. RESERVES ALL PATIENT � 9 COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO THIS DOCUMENT, INCLUDING ALL DESIGN, MANUFACTURING, REPRODUCTION, USE, AND SALES RIGHTS THERETO, EXCEPT TO THE EXTENT SAID RIGHTS ARE EXPRESSLY GRANTED TO OTHERS. THIS DOCUMENT MUST NOT BE DUPLICATED OR DISCLOSED, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF ROESLEIN & ASSOCIATES, INC.. ANY USE OF THE INFORMATION CONTAINED IN THIS DOCUMENT OTHER THAN BY THE AUTHORIZED RECIPIENT FOR THE EXPRESS PURPOSE FOR WHICH IT HAS BEEN PROVIDED IS STRICTLY PROHIBITED. UPON THE REQUEST OF ROESLEIN & ASSOCIATES, INC., THE HOLDER OF THIS DOCUMENT AGREES TO IMMEDIATELY RETURN OR DESTROY THIS DOCUMENT AND ALL COPIES THEREOF IN ITS POSSESSION. 4 ©2019 ROESLEIN & ASSOCIATES, INC. PIPE & ASSOCIATES, INC. RNG PIPING STANDARD AREA 1000 RAINWATER OUTLET PIPING DETAIL ENGINEERS • MANUFACTURERS • CONSTRUCTORS DWG. SHEET REV NO. RA —STD —277 1 OF NOTES: SPIROS1623 3/6/2024 9:56:41 AM S:\PROCESS & ENERGY\RNG STANDARD DOCUMENTS\06 DRAWINGS & DETAILS\01 AREA 1000\MECHANICAL DETAIL DRAWINGS\DWG FILES\RA-STD-288.DWG 08/06/2024 ninTF-:c- .