Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0045548_Application (FTSE)_20240805
�� MCADAMS June 23, 2024 NCDENR - DWR Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 Re: Wilson's Ridge — Phase 3 & 4 Wilson's Mills, North Carolina FRS2020110448 COVER LETTER > HLE-20000 This page updated/revised 20240724 to reflect corrected flow and number of units. Application revised and submitted 20240801 The accompanied Fast -Track Application (FTA 06-21) includes 1,086 linear feet of 8" PVC SDR-35, 1,838 linear feet of 8" PVC C-900, and 8" 316 linear feet of DIP public sewer. The gravity sanitary sewer system for the proposed Wilson's Ridge — Phase 3 & 4 development, located between highway 70 and Wilson's Mills Road near the intersection of Daniel Road in Wilson's Mills, NC, drains to an existing public sanitary sewer manhole in the Highway 70 controlled access to the southwest of the site and is gravity fed to the south. Wilson's Ridge — Phases 3 & 4 will consist of 108 residential lots with a mix of townhomes and single-family homes, associated streets, associated utilities, and infrastructure. The total wastewater flow generated by this project has been calculated to be 24,300 GPD. Sincerely, MCADAMS /II Katie Anderson, PE Project Engineer, Residential Enclosures creating experiences through experience 2905 Meridian Parkway, Durham, NC 27713 / 919. 361. 5000 d DEPARTMENT OF PUBLIC UTILITIES PO BOX 2263 SMITHFIELD, NC 27577 (919) 989-5075 June 7, 2024 Ryan Akers, PE f UN 12 ZQ4 McAdams Re: Sewer Collection Facilities to Serve Wilson's Ridge Phase 3 & 4 1C Serial No: 22-03S-P Plan Approval Dear Mr. Akers: This letter is to confirm that Johnston County Public Utilities has reviewed the plans and technical specifications for the sewer facilities to serve Wilson's Ridge Phase 3 & 4 (JC Project No. 22-035-P) and found them to meet the minimum design and construction standards for Johnston County Public Utilities. Please find attached the Fast - Tract Application and Flow Tracking Form for your submittal to NCDEQ— DWR. Upon completion of the construction or modification, and prior to placing the new construction or modification into service, the following information must be received and approved by the Johnston County Department of Utilities: 1. Engineer's sewer certification (signed by Engineer, Johnston County and submitted to NCDEQ-DWR) 2. As -Built drawings sealed by the Engineer 3. Lien wavier from the utility contractor 4. Recorded plat indicating any necessary utility easements Please find enclosed the "Flow Tracking for Sewer Extension Applications" executed by Johnston County for your submittal to NCDEQ with the permit for the private sewer system extension. Please have the utility contractor schedule a pre -construction conference with this office prior to the installation of the sewer collection facilities. Please be advised that other necessary permits must be received by this office prior to construction. Please contact me at (919) 209-8334 or rudy.wells@oohnstonnc.com if you have any questions or need additional information. Sincerely, Rudy Wells, PE Civil Engineer Cot Mike Keen — Utilities Manager Shannon Stanley — Engineering and Environmental Technician Richard Denning —Construction Inspector State of North Carolina Department of Environmental Quality Division of Water Resources DWIR FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria (Gravity Sewer & Pump Stations/Force Mains) and that plans, specifications and supporting documents have been prepared in accordance with 15A NCAC 02T, 15A NCAC 02T .0300, Division policies, and good engineering practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be immediately available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in ISA NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ➢ Projects that do not meet any part of the minimum design criteria (MDC) documents; ➢ Projects that involve more than one variance from the requirements of 15A NCAC 02T; ➢ Pressure sewer systems utilizing simplex septic tank -effluent pumps (STEPS) or simplex grinder pumps; ➢ Simplex STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); ➢ Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy (second copy may be digital) of Application and Supporting Documents ® Required unless otherwise noted. Signatures on original must be "wet ink" or secure digital signatures. Please do not submit engineering design plans with the application unless specifically requested. B. Cover Letter/Narrative Description (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ Include the permit number/status of any other required sewer permits (downstream/upstream) ➢ If necessary for clarity, include attachments to the application form. ➢ If the project is funded by American Rescue Plan Act (ARPA) funds, please include the ARPA project number in the cover letter and in parentheses under Project Name (Section II.1. of the application). C. Application Fee (All New and Modification Application Packages): ® Submit a check or money order in the amount of $600.00, dated no more than 90 days prior to application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track Application (Required for All Application Packages, Form FTA 10-23): ® Submit the completed and appropriately executed application. ➢ If necessary for clarity or due to space restrictions, attachments to the application may be made. ❑ If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ❑ The Project Name in Item II.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. ❑ The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional En ig'neer. INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION Pagel of 3 ❑ The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). E. Flow Tracking/Acceptance Form (Form: FTSE 10-23) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. ➢ Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. ➢ The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. ➢ Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). ➢ Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area, including the closest surface waters. ➢ General location of the project components (gravity sewer, pump stations, & force main) ➢ Downstream connection points and permit number (if known) for the receiving sewer ❑ Include an aerial location map showing general project area (such as street names or latitude/longitude) so that Division staff can easily locate it in the held. G. Existing Permit (Application Packages for Modifications to an Existing Permit): ❑ Submit a copy of the most recently issued existing permit. ❑ Include a descriptive and clear narrative identifying the previously permitted items to remain in the permit, items to be added, and/or items to be modified (the application form itself should include only include items to be added/modified), The narrative should also include whether any previously permitted items have been certified. ❑ The narrative should clearly identify the requested permitting action and accurately describe the sewers to be listed in the final permit. H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A NCAC 02T .0305(h)(1), submit documentation of power reliability for pumping stations. ➢ This alternative is only available for average daily flows less than 15,000 gallons per day ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per ISA NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Property Owners' Associations ❑ Per 15A NCAC 02T .0115(c), submit the properly executed Operational Agreement (FORM: HOA). ❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM: DEV). For more information, visit the Division's collection systems svebsite INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778-8211 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5095 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 3800 Barrett Drive Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27609 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 571-4718 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pender (910) 796-7215 (910) 350-2004 Fax Winston-Salem Reqional Office 450 W. Hanes Mill Road Suite 300 Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Water Quality Section Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 776-9800 (336) 776-9797 Fax INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION Page 3 of 3 This app revised/re-signed and submitted 20240801 to correct requested flow. State of North Carolina TMAYDepartment of Environmental Quality Lj-"R Division of Water Resources Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 10-23 & SUPPORTING DOCUMENTATION Application Number: WQ0045548 (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name; J" hr%(co party, mums' ality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State/County ❑ Municipal ❑ Other 3. Signature authority's name: Chandra C Farmer, PE per 15A NCAC 02T .0106(b) Title: Director of Utilities 4. Applicant's mailing address: 309 East Market Street PO Box 2263 City; Smithfield State: NC Zip: 27577- 5. Applicant's contact information: Phone number: (919) 209-8333 Email Address: Chandra. farmer(a)iohnstonna.com H. PROJECT INFORMATION: 1. Project name: Wilson's Ridge - Phase 3 and 4 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project ❑ ARPA funded If a modification, provide the existing permit number: WQ00 and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Johnston County 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.576676' Longitude:-78.360486' 5. Parcel ID (if applicable): 17KO801 IA (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Katherine Anderson, PE License Number: 054022 Firm: McAdams Co. Mailing address: 621 Hillsborough Street, Suite 500 City: Raleigh State: NC Zip: 27603- Phone number: (919) 361-5000 Email Address: knderson a,mcadamsco.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Central Johnston County Regional WW Facility Permit Number: NCO030716 Owner Name: Johnston County V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ0044376 2. Downstream (Receiving) Sewer Information: 8 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00060 Owner Name(s): Johnston County FORM: FTA 10-23 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [—]Yes [:]No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic % Commercial % Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ® No ➢ If yes provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow',b No. of Units Flow Single-family Homes 75 gal/Bedroom 324 24,300 GPD gal/ GPD gal/ GPD gal/ GPD gall GPD gal/ GPD Total 24,300 GPD a See 15A NCAC 02T .0114(b),(d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e. proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 24,300 GPD (per 15A NCAC 02T .0114 and G.S. 143-215.1) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 10-23 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 1086 SDR-35 8 1838 C-900 8 316 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.Lb. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 10-23 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T .0305(f) & (g)? ® Yes ❑ No 15A NCAC 0?.T 0105(f) contains minimum senarations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB fiom normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305( or (a), see Section X.1 of this application * 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(fl cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ®Yes [—]No ❑ NIA ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Neuse ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes [:]No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 10-23 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version) and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project the full technical review is required 2. Professional Engineer's Certification: I, Katherine Anderson, PE , attest that this application for Wilson's Ridge Phase 3 and 4 (Professional Engineer's name from Application Item I11.1.) (Project Name from Application Item II.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): SEAL 054022 Digitally signed by Katherine Anderson Date: 2024.07.26 14:32:15-04'00' I, 0ma(1 &_ C . Teamor , attest that this application for A 1 (Signature Authority Name from Application Item I.3.) (Project Name from Ap 1 ation Item II.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: — Date: 30 b� FORM: FTA 10-23 Page 5 of 5 State of North Carolina Department of Environmental Quality R Division of Water Resources t)lvi lion of water Resource Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Johnston County Project Name for which flow is being requested: Wilson's Ridge Ph 3,4 More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: 210 WWTP - Outfall 2 b. WWTP Facility Permit #: NCO030716 All flows are in MGD c. WWTP facility's permitted flow 4 d. Estimated obligated flow not yet tributary to the WWTP 0.8074 to be diverted e. WWTP facility's actual avg. flow 1.469 *Estimated f. Total flow for this specific request 0.0243 g. Total actual and obligated flows to the facility 2.3007 h. Percent of permitted flow used 37% existing, 58% with paper II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / po, Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Wilson's 0.2631 5898mod 1.440 0.5760 0.1515 0.4146 0.1614 Reedy 42510 12.096 4.8384 1.4691 * 0.8326 2.3018 2.5266 The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Wilsons Ridge Phase 3-4 Outfall Downstream Permit Number: WQ0044376 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Chandra C. Farmer, PE certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the plamled improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. 1 , r )6 Signing Official Signature Date Title of Signing Official Page 2 of 6 I•TSE 10-18 " V� � ~: � ''k -pk�` - .���- � .cem,� S � # \& � � � •. , � / % \/ - / � -~ ) � \ © ^ . ^ �-�� � �Q |. � � � . .. ' ! c « ltkg � kn G,>g,p fie+ N WILSON'S RIDGE USGS TOPO MAP I � 0 1,00 200 4,000 PROJECT $:2020110448 �ff Feet 1n -lpn feet WILSON`SMILLS, NORTH CAROLINA W A DA M.S: 2 MCADAMS JUN 12 2024 LETTER OF TRANSMITTAL Date' June 12, 2024 HAND DELIVERY To: NCDEQ— Raleigh Regional Office Re: Wilson's Ridge — Phases 3 + 4 3800 Barrett Drive NCDEQ— Fast Track Submittal Raleigh, North Carolina 27609 Job #: 2020110448 I am sending you the following items: Drawings L, Letter Statement of Qualifications Specifications! Submittal Other Plans ❑ Prints QUANTITY UNIT DESCRIPTION 2 Copies Fast Track Application 1 Each Cover Letter 1 Each Check for $600 made payable to NCDEQ 1 Each FTA 10-23 and FTSE 10-23 1 Each USGS Topo Map (8.S-inch x 11-inch color copy) Transmitted as checked below: For approval Foryouruse As requested Remarks: Copy to: For review + comment Other Other Signature: _ tAkers, PE, L D® AP / tp or, Residential eieatiny, experiences through experience 2905 Meridian Parkway, Durham, NC 27713 / 919. 361. 5000 Wilson, Susan A From: Tracie Patterson < Patterson @mcadamsco.com> Sent: Tuesday, July 16, 2024 1:40 PM To: Wilson, Susan A Cc: Ryan Akers; Katie Anderson Subject: [External] RE: Fast Track Sewer Extension Permit Application Wilson's Ridge - Phase 3 and 4 (WQ0045548) Follow Up Flag: Follow up Flag Status: Flagged You don't often get email from patterson@mcadamsco.com. Learn why this is important CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Susan, followed up with Katie Anderson and have the responses to your comments (shown below in red) and the items she refers to as being in the resubmittal in this link for you M 2024-07-16 Wilson's Ridge Fast Track Resubmittal to Susan : 1. I've attached the site map that Ryan had sent for Wilson's Ridge Phase 1,2 and 5 (also for Wilson's Ridge — Phase 3 and 4 Outfall). If you would look this over and see if you can use it or something similar for this project. Just something that outlines this site and where Phase 3 and 4 are in relation to Phase 1,2 and 5 (and Phase 3 and 4 Outfall). An updated Aerial Map is included with this resubmittal showing Phases 3 & 4 in relation to the whole project site area. 2. 1 should have asked Ryan to provide this with the other applications —but if you could provide a flow schematic showing how the gravity sewer lines for each project tie-in together and where (and how the project ties -in to the existing Johnston County system). I've attached a couple of good flow schematic examples that were submitted for other projects. A Sewer flow diagram is included with this resubmittal. 3. Would you reconfirm that no 404/401 permit is needed and this project complies with Neuse River buffer setbacks, as there does appear to be surface waters along the site. Per the Approved CD's this project compiles with the Neuse River Buffer setback requirements and does not require a 404/401 permit. Please let me know if you need anything else in order to proceed with the review. I'd love to know the estimated timeframe of approval as well. Thank you so much! FTracie Patterson Lead Project Coordinator Office: 919. 361. 5000 patterson@mcadamsco.com 621 Hillsborough Street, Suite 500 Raleigh, NC 27603 JOIN OUR TEAM in V 'JIlv1r,4nei From: Wilson, Susan A <susan.wilson@deq.nc.gov> Sent: Monday, July 15, 2024 9:17 AM To: Trade Patterson <patterson@mcadamsco.com> Subject: FW: Fast Track Sewer Extension Permit Application Wilson's Ridge - Phase 3 and 4 (WQ0045548) CAUTION: This email is NOT from McAdams. DO NOT click links or open attachments unless you verify the sender and content. From: Wilson, Susan A Sent: Friday, July 12, 2024 10:46 AM To: kanderson@mcadamsco.com Cc: Chandra Farmer (chandra.farmer@iohnstonnc.com)<chandra.farmer@iohnstonnc.com>; Rudy Wells <rudy.wells@iohnstonnc.com> Subject: Fast Track Sewer Extension Permit Application Wilson's Ridge - Phase 3 and 4 (WQ0045548) Hi Katherine — I've done an initial review of the application for Wilson's Ridge — Phase 3 and 4 and just have a few comments. 1. I've attached the site map that Ryan had sent for Wilson's Ridge Phase 1,2 and 5 (also for Wilson's Ridge — Phase 3 and 4 Outfall). If you would look this over and see if you can use it or something similar for this project. Just something that outlines this site and where Phase 3 and 4 are in relation to Phase 1,2 and 5 (and Phase 3 and 4 Outfall). 2. 1 should have asked Ryan to provide this with the other applications — but if you could provide a flow schematic showing how the gravity sewer lines for each project tie-in together and where (and how the project ties -in to the existing Johnston County system). I've attached a couple of good flow schematic examples that were submitted for other projects. 3. Would you reconfirm that no 404/401 permit is needed and this project complies with Neuse River buffer setbacks, as there does appear to be surface waters along the site. Thank you. Let me know if you have any questions. Please provide the above information within 30 days. If additional information/corrected application is not received within 30 days, your application will be returned, and you will need to resubmit along with the fee (ref. 15A NCAC 02T.0107(e)(2)]. Respectfully, Susan Wilson Environmental Engineer (Part Time, Temporary) Water Quality Regional Operations - Raleigh Regional Office NC Department of Environmental Quality Office: 919-791-4240 Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. N WILSON'S RIDGE - PHASES 3&4 SITE AERIAL MAP 0 495 990 1,980 PROJECT #: 2020110448 Feet 1:12,000 WILSON'S MILLS, NORTH CAROLINA • s High •W ibons Nil Is _ t A 228, • � t1 • s% N Site -.,, . ' • - ?J W. Mi` Existing Gravity • Sewer • Existing Gravity 4 • Sewer • t �r Pik 0/ li, 30 .• # a 40 Ct- 1 - Copyright:© 2013 Na tonal Geograp is Society, i-cubed N, ! 1 �� • N WILSON'S RIDGE Sewer Flow Diagram 0 410 820 1,640 PROJECT #: 2020110448 Feet 1:10,000 WILSON'S MILLS, NORTH CAROLINA r 1 / So 916 Gravel J Q J pit Richardson CIT �• _ Ch Y50 Hil High �' •Wilsons billssm ` i SITE µ'iLn mm% - � N8� • �� -=-t'— Ch I L 0 N:-, _ •rm /y.Casiuter . f.. J�• C6T .4-1 1i — Lt A N A 0 5001,000 2,000 Feet 1:24,000 \� Jd �CD • �: �� i• 1 11 / t 190C ' —1 ,L 2031 1 �� 'Coyrig-ht:©�2013 National Geographic Society, i-cuble., Y PiP , WILSON'S RIDGE - PHASE 3 & 4 USGS TOPO MAP PROJECT #: 2020110448 WILSON'S MILLS, NORTH CAROLINA