November 17, 2014
Heather Adams
Enviorlink
P.O. Box 670
BaileyNC 27807
SUBJECT: 11/12/2014 Compliance Evaluation Inspection
Lake Creek Corporation
Lake Creek Corp-Baytree Lakes.
Permit No: WQ0018708
Bladen County
Dear Ms. Adams:
Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on 11/12/2014.
The Compliance Evaluation Inspection was conducted by Tony W Honeycutt of the Fayetteville Regional Office. The
facility was found to be in Non- Compliance with permit WQ0018708.
Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any
questions, please call me at (910) 433-3339.
S' cerely,
Tony W Honeycutt
Environmental Specialist
NCDENR
Division of Water Resources
Water Quality Regional Operations Section
Fayetteville Regional Office
cc: Tony Baldwin, ORC
Central Files .
-ayettevi�'i'le
Water Quality Program - 225 Green St, Ste. 714
Fayetteville, North Carolina 28301-5095
Phone: 910-433-33001 FAX: 910486-07071 Customer Service:1-877-623-6748
An Equal Opportunity 1 Affirmative Action Employer
Compliance Inspection Report
Permit: WQ0018708. Effective: 02/03/09 Expiration: 06/30/17 Owner: Lake Creek Corporation
SOC: Effective: Expiration: Facility: Lake Creek Corp=Baytree Lakes
County: Bladen
Region: Fayetteville
r
Contact Person: Brian G Cox Title: Phone: 919-662-7272
Directions to Facility:
System Classifications: Si, WW2,
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 11/12/2014 Entry Time: 0,1:OOPM Exit Time: 03:OOPM
Primary. Inspector: Tony W-Honeycutt ► Phone: 910-433-3339
Reason for_Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Wastewater Irrigation
Facility Status: Q Compliant ® Not Compliant
Question Areas:
Miscellaneous Questions 'Record Keeping End Use -Irrigation
(See attachment summary)
Page: 1
T.
q %
Permit: WO0018708 Owner - Facility: Lake Creek Corporation
Inspection Date: 11/12/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
The influent flow into the system is exceeding the allowable permitted flow each month. There is an enforcement case
pending with the AG's office concerning this issue. This issue needs to be addressed as soon as possible.
The solids holding tank in the package plant is completely full,(solid). This does not allow for proper operation of the
treatment system. It causes the solids to be passed along into the lagoon. The lagoon is not a treatment lagoon for the
soilds and this matter needs to be addressed as soon as possible.
Due to the failure to resolve the matter with the solids tank as noted above and also in last years inspection report, it is
recommended that a lagoon survey be conducted to check the levels of solids accumulation in the lagoon.
Spray irrigation operations were taking place at the time of the site visit. When the operator was asked about the winter
overseed crop, he told the inspector that the winter crop had been broadcast over the fiels area. The operator was informed
that unless the seed makes direct contact with the ground (better if below ground) and the temperatures are correct, there
will be no germanation of the seeds. This would result in a winter crop that is unacceptable/failed. It is recommended that a
winter overseed crop be drilled into the spray fields as soon as possible.
At this point in time there was no evidence of any type of overseed crop being broadcast or drilled. A follow-up visit will be
conducted (drive by within 30 days) to check and see if there is a winter crop present to recieve the nutrients from the spray
operations.. Without a exceptable winter crop in place, any spray irrigation events would be in violation of the systen permit,
WQ0018708.
The facility is also still several years in the rears with its premit renewal fees. This also should be addressed as soon as
possible.
Page: 2
I
Permit: WQ0018708 Owner -, Facility: Lake Creek Corporation
Inspection Date:.11112/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Type
Reuse (Quality)
Lagoon Spray,• LR
Infiltration System
Activated Sludge Spray, LR
Single Family Spray, LR
Recycle/Reuse
Activated Sludge Drip, LR
Activated Sludge Spray, HR
Single Family Drip
Record Keeping
Is a copy of current permit available?
Are monitoring reports present: NDMR?
NDAR?
Are flow rates less than of permitted flow?, '
Are flow rates less than of permitted flow? .
Are application rates adhered to?
Is GW monitoring being conducted, if required (GW-59s submitted)?
Are all samples analyzed.for all required parameters?
Are there any 2L GW quality violations?
Is GW-59A certification form completed for facility?
Is effluent sampled for same parameters as GW?
Do effluent concentrations exceed GW standards?
Are annual soil reports available?
#Are PAN records required?
# Did last soil report indicate a -need for lime?
If so, has it been applied?
Are operational logs present?
Are lab sheets available for review?
Do lab sheets support data reported on NDMR?
Do lab sheets support data reported on GW 59s?
Are Operational and Maintenance records present?
Were Operational and Maintenance records complete?
Has, permittee been free of public complaints in last 12 months?
Is a copy of the SOC readily available?
Yes No NA NE
El
El
Yes No NA NE
■❑❑❑
❑ ❑ ❑
■ ❑ -❑ ❑
❑ 0 '❑ ❑
❑.0a❑
❑ ❑ ❑
❑ ❑ ❑
M ❑ ❑ ❑
❑ ❑ ❑ M..
❑❑❑■
11 El. ❑M.
❑■❑❑
Ma❑❑
■❑❑❑
❑■❑❑
❑❑■❑
❑ ❑ ❑
❑ ❑ ❑
❑.❑❑■
❑ ❑
❑ ❑ ❑
❑ ❑ ❑
Page: 3
Permit: WQ0018708 Owner - Facility: Lake Creek Corporation
Inspection Date: 11/12/2014 Inspection Type : Compliance Evaluation Reason for Visit: Routine
No treatment units bypassed since last inspection?
Comment: The flow into the system exceeds the permitted value.
End Use -Irrigation
Yes No NA NE
Are buffers adequate?
0 ❑ ❑ ❑
Is the cover crop type specified in permit?
®❑ ❑ ❑
Is the crop cover acceptable?
❑ ■ ❑ ❑
Is the site condition adequate?
®�
Is the site free of runoff / ponding?
®❑ ❑
Is the acreage specified in the permit being utilized?
®❑ ❑ ❑
Is the application equipment present?
®❑ ❑ ❑
Is the application equipment operational?
®❑ ❑ ❑
Is the disposal field free of limiting slopes?
®❑ ❑ ❑ .
Is access restricted and/or signs posted during active site use?
®❑ ❑ ❑
Are any supply wells within the CB?
❑ ❑ ❑
Are any supply wells within 250' of the CB?
❑ ❑ ❑ M
How close is the closest water supply well?
❑ ❑ ❑ E
Is municipal water available in the area?
❑ ! ❑ ❑
# In only: Does the permit call for monitoring wells?
®❑ El El
Are GW monitoring wells located properly w/ respect to RB and CB?
®❑ ❑ ❑
Are GW monitoring wells properly constructed, including screened interval?
❑ ❑ ❑
Are monitoring wells damaged?
❑ ❑ ❑ M
Comment: The window for irrigation on the burmuda crop is closed and there is no indication of a winter
overseed crop being present at this time.
Page: 4