HomeMy WebLinkAboutNC0087891_Authorization to Construct_20110617PR• HCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary June 17, 2011 Mr. Nathan Bennett, County Manager East Yancey Water & Sewer District Room 11, Courthouse Burnsville, North Carolina 28741 SUBJECT: Authorization to Construct A to C No. 087891A01 East Yancey Water & Sewer District South Toe River Wastewater Treatment Plant Yancey County Project No. E-SRG-T-05-0141 Dear Mr. Bennett: A letter of request for an Authorization to Construct was received November 3, 2008, by the Division of Water Quality (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of the new 0.125 MGD South Toe River Wastewater Treatment Plant, with discharge of treated wastewater into the South Toe River in the French Broad River Basin. This authorization results in the design and permitted capacity of 0.125 MGD, and is awarded for the construction of the following: A headworks structure including a cylindrical (mechanical) bar screen rated at 0.464 mgd peak flow and a manual by-pass bar screen; dual sequencing batch reactors (SBR), each reactor sized at 0.115 MG with 5 Hp floating mixer, decanter, fine -bubble diffusers and dual 50 gpm sludge pumps; a 0.026 MG post equalization tank with three (3) 87 gpm pumps and coarse -bubble diffusers; three (3) 273 cfm blowers and one (1) 81 scm blower; dual effluent disk filters, each rated at 0.3125 mgd peak flow; dual bank ultraviolet disinfection system, with each bank rated at 0.3125 mgd peak flow; effluent flowmeter and composite sampling station; a return plant drain pump station consisting of dual 80 gpm pumps; a 0.063 MG aerobic digester/holding tank with decanter, coarse bubble diffusers and 200 gpm sludge transfer pump; a 668 ft2 Laboratory building; 150 kW backup emergency generator with automatic transfer switch; plant SCADA system; and associated site work, electrical work, and yard piping, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 One Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 OCarolina Phone: 919-807-63001 FAX: 919-807-64921 Customer Service:1-877.623-6748 Internet: www.ncwaterquality.org Na&Aally An Equal Opportunity 1 Affirmative Action Employer Mr. Nathan Bennett, County Manager June 17, 2011 Page 2 This Authorization to Construct is issued in accordance with Part III, Paragraph A of NPDES Permit No. NCO087891 issued April 13, 2005, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0087891. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Asheville Regional Office, telephone number (828) 296-4500, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: Construction Grants & Loans, DWQ/DENR, 1633 Mail Service Center, Raleigh, NC 27699-1633. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, Mr. Nathan Bennett, County Manager June 17, 2011 Page 3 and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Penmittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional information, please contact Seth Robertson, P.E. at telephone number (919) 715-6206. Sincerely, ,,,6Coleen H. Sullins kp:sr cc: Randall D. Hintz, P.E. — McGill Associates, P.A., 55 Broad Street, Asheville, NC 28801 Yancey County Health Department DWQ, Asheville Regional Office, Surface Water Protection DWQ, Technical Assistance and Certification Unit DWQ, Point Source Branch, NPDES Program Daniel Blaisdell, P.E. Ken Pohlig, P.E. SRG File no East Yancey Water & Sewer District A To C No. 087891A01 Project No. E-SRG-T-05-0141 Issued June 17, 2011 Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the modifications and improvements to the South Toe River WWTP, located on Wyatt Town Road in Yancey County for the East Yancey Water & Sewer District, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: A headworks structure including a cylindrical (mechanical) bar screen rated at 0.464 mgd peak flow and a manual by-pass bar screen; dual sequencing batch reactors (SBR), each reactor sized at 0.115 MG with 5 Hp floating mixer, decanter, fine -bubble diffusers and dual 50 gpm sludge pumps; a 0.026 MG post equalization tank with three (3) 87 gpm pumps and coarse -bubble diffusers; three (3) 273 cfin blowers and one (1) 81 scm blower; dual effluent disk filters, each rated at 0.3125 mgd peak flow; dual bank ultraviolet disinfection system, with each bank rated at 0.3125 mgd peak flow; effluent flowmeter and composite sampling station; a return plant drain pump station consisting of dual 80 gpm pumps; a 0.063 MG aerobic digester/holding tank with decanter, coarse bubble diffusers and 200 gpm sludge transfer pump; a 668 ft2 Laboratory building; 150 kW backup emergency generator with automatic transfer switch; plant SCADA system; and associated site work, electrical work, and yard piping, in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. We understand that the new limits associated with this new 0.125 MGD WWTP now apply. Signature Date Registration No. Send to: Construction Grants & Loans DENR/DWQ 1633 Mail Service Center Raleigh, NC 27699-1633