HomeMy WebLinkAboutWQ0002838_Monitoring - 06-2024_20240731Monitoring Report Submittal
Permit Number#*
Name of Facility:*
Month:* June
WQ0002838
Deerhurst MHP
Report Information
Type *
NDMR, NDAR-1, NDAR-2, NDMLR
Confirmation Email Address:
Name of Submitter: *
Signature:
Date of submittal:
Initial Review
Year:* 2024
Upload Document*
Deerhurst WQ0002838 06-2024.pdf 3.92MB
PDF Only
Please upload one PDF containing all applicable monitoring reports
(i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59).
dsears@envirolinkinc.com
Daniel Sears
Reviewer: Wanda.Gerald
7/31 /2024
This will be filled in automatically
Is the project number correct?* W00002838
Is the monitoring report accepted?* Yes NO
Regional Office* Raleigh
Reviewer: _anonymous
Review Date: 8/5/2024
FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of
Permit No.: WQ0002838
Facility Name: Deerhurst MHP WWTF
County: Wake
Month: June
Year: 2024
PPI: 001 -T
Flow Measuring Point: ❑ Influent 0 Effluent ❑ No flow generated
Parameter Monitoring Point: ❑ Influent ❑ Effluent ❑ Groundwater Lowering ❑ Surface Water
Parameter Code
50050
00310
00940
50060
31616
00610
00625
00620
00600
00400
00665
70300
00530
G
>
LL G)
U
=
O
LO
m
U
d
C
y
U
E
L
U
m
=
_
G
ZZ
=
G)3
o
Z
°pL
=
a
y
~° y Ctn
GO
d )
CUn
24-hr
hrs
GPD
mg/L
mg/L
mg/L
#/100 mL
mg/L
mg/L
mg/L
mg/L
su
mg/L
mg/L
mg/L
1
11,349
2
11,349
3
13:15
0.75
11,349
1.16
6.96
4
13,142
5
13,142
6
13,142
7
13,142
8
13,142
9
13,142
10
19:00
0.5
13,142
1.31
6.9
11
12,162
12
12,162
13
12,162
141
12,162
15
12,162
16
12,162
17
8:30
0.75
12,162
1.19
6.9
18
13,587
191
13,587
20
13,587
21
13,587
22
13,587
23
13,587
24
8:25
0.75
13,587
1.26
6.9
25
10,341
26
10,341
27
10,341
28
10,341
291
1
10,341
301
10,341
31
Average:
12,278
1.23
Daily Maximum:
13,587
1.31
6.96
Daily Minimum:
10,341
1.16
6.90
Sampling Type:
Recorder
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Grab
Monthly Avg. Limit:
Daily Limit:
Sample Frequency:1
Continuous
1 4 x Year
3 x Year
Weekly
4 x Year
4 x Year
4 x Year
4 x Year
4 x Year
Weekly
4 x Year
3 x Year
4 x Year
Sampling Person(s)
Certified Laboratories
Name: Chris House
Name
Name: Meritech Labs
Name:
Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? 0 Compliant ❑ Non -Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective
actions) taKen. Attacn aaaltlonal sneets IT necessa
Operator in Responsible Charge (ORC) Certification
Permittee Certification
ORC: William Lamm
Permittee: Yes Communities
Certification No.: 11693
Signing Official: Daniel Sears
Grade: WW4 Phone Number: 252-236-1422
Signing Official's Title: Compliance Manager
Has the ORC changed since the previous NDMR? ❑ Yes 0 No
Phone Number: 984-365-9155 Permit Expiration: 6/3/2025
72 2 24
72 24
Signature Date
Signatur Date
By this signature, I certify that this report is accurrate and complete to the best of my knowledge.
I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance
with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on
my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the
information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant
penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
Loading:Monthly
FORM: NDAR-1 10-13
NON -DISCHARGE APPLICATION REPORT (NDAR-1)
Page of
Did the application rates exceed the limits in Attachment B of your permit?
Compliant ❑ Non -Compliant
Were adequate measures taken to prevent effluent ponding in or runoff from the sites? ❑ Compliant ❑ Non -Compliant
Was a suitable vegetative cover maintained on all sites as specified in your permit? 0 Compliant ❑ Non -Compliant
Were all setbacks listed in your permit maintained for every application to each permitted site? 0 Compliant ❑ Non -Compliant
Were all freeboards maintained in accordance with the specified freeboard heights in your permit? 0 Compliant ❑ Non -Compliant
If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective
action(s) taken. Attach additional sheets if necessary.
Operator in Responsible Charge (ORC) Certification
Permittee Certification
ORC: William Lamm
Permittee:
Yes Communities
Certification No.: 11693
Signing Official: Daniel Sears
Grade: WW4 Phone Number: 252-236-1422
Signing Officials Title: Compliance Manager
Has the ORC changed since the previous NDAR-1? ❑ Yes 0 No
Phone Number: 984-365-9155 Permit Exp.: 6/3/25
07/25/2024
7/26/24
Signature Date
Signa re Date
By this signature, I certify that this report is accurrate and complete to the best of my knowledge.
I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance
with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the
information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant
penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617