Loading...
HomeMy WebLinkAbout20072022 Ver 1_More Info Letter_20071221O~O~ W A T ~9pG ^ W Imo"" >_ 11J_WV =i December 21, 2007 EXPRESS REVIEW NOTIFICATION LETTER East Durham Development Company, LLC Attn: Mr. Michael Whitehead 201 Shannon Oaks Circle Raleigh, NC 27511 Project Name: Sierra Residential Subdivision Dear Mr. Whitehead: Michael F. Easley, Governor William G. Ross Jr., Secretary North Cazolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality Durham County EXP# 07-2022 On December 19, 2007, the Express Review Program of the Division of Water Quality (DWQ) received your application for the above referenced project. The DWQ has determined that your application will require additional information. Please provide the following information so that we may continue to review your project and prevent denial of your application as required by 15A NCAC 2H .0506: 1. The submitted application is for a residential subdivision, NW29 (GC 3705). You have currently submitted a partial application (only including the road structures). Large subdivision projects can be phased, geographically by quadrants, but not as you have submitted. It is recommended that an office meeting be conducted after January 1, 2008 (preferably on January 2°a) in order to clarify the numerous items detailed below. The express clock will stop for the holidays at Spm of December 21, 2007 and restart again on January 2, 2007. 2. Please follow the guidelines in the PCN addendum. a. As per the guidelines, site "plans must show all built-out structures and impervious cover. The plans must include the final grading contours with elevations. The plans must indicate all utilities and easements". b. Additionally, platted parcels must be developable without further impacts to jurisdictional and non- jurisdictional wetlands, streams, water features, and State regulated buffers. These parcels must be shown in order to determine that no further impacts will occur. c. Please clearly depict all of the wetland boundaries on the property. d. Please provide maps (at least 1:100) in sufficient detail to observe all parcels and features. 3. Diffuse Flow Provisions: a. Every proposed BMP structure for stormwater management or diffuse flow provisions shall be permanent, and not temporary. If a temporary BMP is needed for phase I and will be removed during future phases of development, please understand that a new (and appropriate) BMP must be approved by the DWQ and be installed before any existing BMP is removed. b. All buffer widths shall be measured from top of bank on both sides of all streams. Please show the top of bank along all streams on plans along with both Zones (1 & 2) of riparian buffer. c. Please site and design level spreaders in accordance with the current North Carolina Stormwater Best Management Practices Design Manual available at http://h2o.enr.state.nc.us/su/bmp fortns.htm. Please pay particular attention to the following items: 401 Oversightl Express Review Permitting Unit 1650 Mail Service Center, Raleigh, North Carolina 27699-1650 2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604 Phone: 919-733-17861 FAX 919-733-68931 Internet: http://h2o.enr.state.nc.us/ncwetlands An Equal OpportunitylAffirmative Action Employer- 50% Recycledl10% Post Consumer Paper N ne Carolina tura!!y i. Locating devices to follow existing contours. ii. Avoiding steep slopes (Maximum 8% for grass filter strip and 6% for forest filter strip). Slopes were measured to range between 16% and 20%. iii. Avoiding draws down slope of level spreaders. iv. Level spreaders shall be designed for 1 "/hr storm with bypass for the 10-yr storm or for the 10-yr storm without bypass. v. Maximum length for any level spreader shall be 136 ft. d. Please delineate the drainage areas to the level spreaders, indicating amount of impervious area for each drainage area, and submit design flow calculations for the 1 "/hr and 10-yr storm. e. Bypass structures shall be directed away from the level spreaders. £ Please reconcile the level spreader table shown on plan sheet C703 and that in the main application document. In addition, some level spreaders are not shown on the plans. These include those with end sections FES 9, 21, 27, 33, 58, 64 and 68. g. Please submit a level spreader supplement form for each level spreader, including the Design Summary and Required Items Checklist along with all requested items. h. Please submit one original and two copies of a notarized Inspection and Maintenance Agreement Form for the proposed level spreaders. i. If level spreaders are designed to receive flow from any BMP, please indicate BMP types and locations, and include BMP outflow calculations. j. Please see Option 2 of the Stormwater Management for Buffer Rules Section of the PCN Addendum and also Section 8.3.6 of the NC BMP Manual (page 8-8) for guidance on other BMP options where level spreaders are not appropriate. k. Please include velocity dissipator design sheets. Please respond within five (5) days of the date of this letter by sending three (3) copies of this information. The Express Review Program is a process that requires all parties to participate in a timely manner. This letter only addresses the application review and does not authorize any impacts to wetlands, waters or protected buffers. Please contact Lia Myott at (919) 733-9502 if you have any questions. Sincerely, ~~ Cyndi Karoly, Supervisor 401/Express Review Oversite Unit CBK/lem cc: DWQ Raleigh Regional Office USAGE Raleigh Field Office Central Files File copy Mr. John E. Schrum, Horvath Associates P.A., 16 Consultant Place, Suite 201, Durham, NC 27707