Loading...
HomeMy WebLinkAboutWQ0011313_More Information (Requested)_20240610ROY COOPER Governor ELIZABETH S. BISER Secretary fssrQUAM,Ao t RICHARD E. ROGERS, JR. NORTH CAROLINA Director Environmental Quality June 10, 2024 HERBERT H. PATRICK, JR. — PRESIDENT FESTIVA REAL ESTATE HOLDINGS, LLC ONE VANCE GAP ROAD ASHEVILLE, NORTH CAROLINA Subject: Application No. WQ0011313 Additional Information Request #1 Peppertree Resort WWTP High -Rate Infiltration System Carteret County Dear Mr. Patrick, Division of Water Resources' Central and Regional staff have reviewed the application package received on March 15, 2024. However, the Division requires additional information before completing our review. Please address the items on the attached pages no later than the close of business on July 11, 2024. Please be aware that the Applicant is responsible for meeting all requirements set forth in North Carolina rules and regulations. The Applicant is also responsible for any oversights that occur during the review of the subject application package. The Division may return the application as incomplete pursuant to 15A NCAC 02T .0107(e)(2) if any omissions are made when responding to the outstanding items in Sections A through F or the Applicant fails to provide the additional information on or before the above - requested date. Please reference the subject application number when providing the requested information. The Applicant shall sign, seal, and date (where applicable) all revised and/or additional documentation and submit an electronic response to my attention via the Non -Discharge online portal. If you have any questions regarding this request, please contact me at (919) 707-3656 or leah.parente&deq.nc.gov. Thank you for your cooperation. Sincerely, EDocuSigned by: -.G 4 1p-� G FC95C4AC2F95474... Leah H. Parente, Geologist/Hydrogeologist Division of Water Resources cc: Wilmington Regional Office, Water Quality Regional Operations Section (Electronic Copy) Laserfiche File (Electronic Copy) D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROLINA oepammem of eadmamemai uuahty /`� 919.707.9000 Mr. Patrick June 10, 2024 Page 2 of 4 A. Operator in Responsible Charge (ORC): 1. In the submitted application for Permit WQ0011313, Daniel E. Fortin is listed as the Back-up ORC for the Peppertree Resort High -Rate Infiltration System. However, Mr. Fortin has not been designated as a Back -Up ORC for this facility. The Applicant shall submit a Water Pollution Control System Operator Designation Form (attached) to designate Mr. Fortin as a Back -Up ORC for this facility. It is important to note that the Non -Discharge Branch does not process this form. Please submit the form to the Water Pollution Control System Operators Certification Commission (WPCSOCC) by mail, fax, or email at the following address: a. Mail: WPCSOCC Mail Service Center Raleigh, NC 27699-1618 b. Fax: (919) 715-2726 c. Email: certadmin@deq.nc.gov B. Operational Agreement: 1. The Operational Agreement that was submitted as a part of the renewal application package for Permit WQ0011313 is a copy of a previous Operational Agreement dated August 31, 2018. Please submit a new Operational Agreement pursuant to 15A NCAC 02T .0115(a)(2). C. Articles of incorporation, Declarations, and By-laws: The Declarations and By-laws for Festiva Real Estate Holdings, LLC were not included in the renewal application package submitted for Permit WQ0011313. Please submit a copy of the Declarations and By-laws pursuant to 15A NCAC 02T .0115(c). D. Infiltration Sites: 1. The areas of Infiltration Site 1 and Infiltration Site 2 do not match the areas listed for these sites in Permit WQ0011313 issued on November 15, 2018. The Applicant shall provide an explanation for the discrepancy, or the Applicant shall submit a revised version of page 3 of form HRIS-R 02-21. All areas should be listed in acres. E. Site May: 1. The Applicant shall submit an updated site map that meets the requirements of 15A NCAC 02C .0105(e)(5), 02T .0108(b (1Z )(B), 02T .0704(d) that shall include: a. Legend, north arrow, and scale. b. Topographic contour intervals not exceeding 10 feet or 25 percent of total site relief. c. All habitable residences or places of assembly within 500 feet of the infiltration area. d. Location of all wells, streams (ephemeral, intermittent, and perennial), springs, lakes, ponds, ditches, and other surface drainage features within 500 feet of the infiltration area. e. Location and identification of each monitoring well. £ Latitude and longitude coordinates of each monitoring well to the sixth decimal degree. g. Location and identification of all wastewater treatment and storage units. Mr. Patrick June 10, 2024 Page 3 of 4 h. The perimeter of all infiltration areas with site names as listed in Attachment B. i. Location and ownership of property boundaries within 500 feet of the infiltration area, including rights -of -way and easements. j. Latitude and longitude coordinates of the established horizontal control monument to the sixth decimal degree. k. Elevation of the top of the well casing (i.e., measuring point) relative to a common datum. 1. Depth of water below the measuring point. m. Delineation of the compliance and review boundaries. n. Distance measurements verifying all setbacks. o. Stormwater drainage controls. p. 100-year floodplain (if present). q. The date the map is prepared or revised. r. Location of the groundwater lowering system and discharge point(s). F. Facility Description: 1. The Applicant shall submit a review of the current facility description (below) from a North Carolina licensed Professional Engineer certifying that the description is correct and/or providing a description of any changes that have been made to the facility. "continued operation of an 80,000 gallon per day (GPD) wastewater collectin, wastewater treatment and high -rate infiltration facility consisting of the: continued operation of a wastewater collection system consisting of: 1,175 linear feet (LF) of 8- inch gravity sewer; and all associated piping, valves, controls, and appurtenances; the continued operation of a wastewater treatment system consisting of: a 37,500 gallon flow equalization basin with two 63 cubic feet per minute (CFM) blowers, a 50 gallon per minute (GPM) mixing pump, and two 155 GPM equalization pumps; a manually cleaned bar screen; a flow splitter box; a 15,000 gallon anoxic basin with a 50 GPM mixing pump; a 23,000 gallon anoxic basin with two 94 GPM grinder pumps, and a 50 GPM mixing pump; a flow splitter box; a 3 1, 100 gallon aeration basin with two 300 CFM blowers, and a 170 GPM mixed liquor return pump; two 3,550 gallon clarifiers each with a 22 GPM return activated sludge pump; a 2,400 gallon mudwell with two 50 GPM pumps; two 14.25 square foot (ft) tertiary filters; a 2,240 gallon clear well with two 214 GPM backwash pumps; a 50,000 GPD ultraviolet (LTV) disinfection unit; a 43,500 gallon sludge holding tank with two 182 GPM blowers; a 5,750 gallon dosing tank with 126 GPM and 124 GPM dosing pumps; a Netafim Arkal Model 40 drip irrigation control and filter unit; highwater alarms; and all associated piping, valves, controls, and appurtenances; the continued operation of a wastewater treatment system consisting of: a 5,000 gallon influent lift station/flow equalization basin with two 80 GPM pumps; two 22,500 gallon aeration tanks with two 120 CFM blowers, and two 250 GPM mixed liquor return pumps; two 4,167 gallon clarifiers with four 16 GPM return activated sludge pumps; a mudwell with duplex pumps; two 18 ft2 tertiary filters; a clearwell with two backwash pumps; a 1,345 gallon chlorine contact chamber; a 6,770 gallon dosing tank; two 18,375 aeration tanks with three 120 CFM blowers, and two 200 GPM return mixed liquor return pumps; a 7,700 gallon clarifier with two 26 GPM return activated sludge pumps; a mudwell with duplex pumps; two 18 ft2 tertiary filters; a clearwell with two backwash pumps; a 1,345 gallon chlorine contact chamber; a 45 kilowatt (M) back-up generator; and all associated piping, valves, controls, and appurtenances; and the Mr. Patrick June 10, 2024 Page 4 of 4 continued operation of a high -rate infiltration system consisting of: 1,068 LF of 6-inch PVC force main; approximately 1,388 LF of 4-inch return line; a 0.58 acre high -rate infiltration area with two 0.29 acre fields each containing 6,300 LF of drip line with 0.01 GPM emitters spaced 1 foot on centers; and all associated piping, valves, controls, and appurtenances"