Loading...
HomeMy WebLinkAboutSW3240701_O&M Agreement/Plan_20240724 Operation & Maintenance Agreement Project Name: QuikTrip #1069 Project Location: East Marshville Boulevard, Marshville, NC 28103 Cover Page Maintenance records shall be kept on the following SCM(s). This maintenance record shall be kept in a log in a known set location. Any deficient SCM elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the SCM(s). The SCM(s)on this project include (check all that apply, leave attached the corresponding SCM O&M sheets, and delete all SCM O&M Sheets not applicable to the project): Infiltration Basin Quantity: Location(s): Infiltration Trench Quantity: Location(s): Bioretention Cell Quantity: Location(s): Wet Pond Quantity: Location(s): Stormwater Wetland Quantity: Location(s): Permeable Pavement Quantity: Location(s): Sand Filter Quantity: Location(s): Rainwater Harvesting Quantity: Location(s): Green Roof Quantity: Location(s): Level Spreader- Filter Strip Quantity: Location(s): Proprietary System Quantity: 1 Location(s): About 20ft offset of south property line. Treatment Swale Quantity: Location(s): Dry Pond Quantity: 1 Location(s): Southeast corner of property. Disconnected Impervious Surface Present: No Location(s): User Defined SCM Present: No Location(s): Low Density Present: No Type: I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for each SCM above, and attached O&M tables. I agree to notify NCDEQ of any problems with the system or prior to any changes to the system or responsible party. Responsible Party: Mark Horton Title&Organization: Project Manager-QuikTrip Corporation Street address: 4705 South 129th East Avenue City, state,zip: Tulsa, OK 74134 Phone number(s): 918-615-7700 Email: mhorton@quiktrip.com Signature: Date: I, , a Notary Public for the State of County of , do hereby certify that personally appeared before me this day of and acknowledge the due execution of the Operations and Maintenance Agreement. Witness my hand and official seal, Seal My commission expires Dry Pond Maintenance Requirements Important operation and maintenance procedures: - The drainage area will be managed to reduce the sediment load to the dry pond. - Immediately after the dry pond is established, the vegetation will be watered twice weekly if needed until the plants become established (commonly six weeks). - After the initial fertilization to establish vegetation in the dry pond,fertilizer will not be applied to the dry pond. - The vegetation in and around the basin will be maintained at a height of approximately six inches. - At least once annually, a dam safety expert will inspect the embankment.Any problems that are found will be repaired immediately. After the dry pond is established, it shall be inspected quarterly and within 24 hours after every storm event greater than 1.0 inches. Records of operation and maintenance shall be kept in a known set location and shall be available upon request. Inspection activities shall be performed as follows.Any problems that are found shall be repaired immediately. SCM element: Potential problem: How to remediate the problem: The entire SCM Trash/debris is present. Remove the trash/debris. Areas of bare soil and/or Regrade the soil if necessary to remove the gully, plant ground The perimeter of the SCM erosive gullies have formed. cover and water until it is established. Provide lime and a one-time fertilizer application. The inlet pipe is clogged (if Unclog the pipe. Dispose of the sediment in a location where it will applicable). not cause impacts to streams or the SCM. The inlet pipe is cracked or The inlet device otherwise damaged (if Repair or replace the pipe. applicable). Erosion is occurring in the Regrade the swale if necessary and provide erosion control Erosion (if applicable). devices such as reinforced turf matting or riprap to avoid future swaleproblems with erosion. Sediment has accumulated Search for the source of the sediment and remedy the problem if to a depth greater than the possible. Remove the sediment and dispose of it in a location original design depth for where it will not cause impacts to streams or the SCM. sediment storage. The forebay Erosion has occurred. Provide additional erosion protection such as reinforced turf matting or riprap if needed to prevent future erosion problems. Weeds are present. Remove the weeds, preferably by hand. If pesticide is used,wipe it on the plants rather than spraying. Sediment has accumulated Search for the source of the sediment and remedy the problem if to a depth greater than the possible. Remove the sediment and dispose of it in a location original design depth for where it will not cause impacts to streams or the SCM. sediment storage. The main treatment area Water is standing more than Check the outlet structure for clogging. If it is a design issue, 5 days after a storm event. consult an appropriate professional. Weeds and noxious plants Remove the weeds, preferably by hand. If pesticide is used, wipe it are growing in the main on the plants rather than spraying. treatment area. Dry Pond Maintenance Requirements(continued) SCM element: Potential problem: How to remediate the problem: Shrubs have started to grow on the embankment. Remove shrubs immediately. Evidence of muskrat or Consult a professional to remove muskrats or beavers and repair beaver activity is present. any holes or erosion. The embankment A tree has started to grow on the embankment. Consult a dam safety specialist to remove the tree. An annual inspection by an appropriate professional Make all needed repairs immediately. shows that the embankment needs repair. Clogging has occurred. Clean out the outlet device. Dispose of the sediment in a location gg g where it will not cause impacts to streams or the SCM. The outlet device The outlet device is Repair or replace the outlet device. damaged Erosion or other signs of damage have occurred at Repair the damage and improve the flow dissipation structure. the outlet. The receiving water Discharges from the dry pond are causing erosion or Contact the local NCDEQ Regional Office. sedimentation in the receiving water. Dry Detention Pond Design Summary DRY POND ID FOREBAY MAIN POND 1 Temporary Pool El: Temporary Pool El: 536.00 Clean Out Depth: Clean Out Depth: 1.1 Pretreatment No Sediment Storage El: Sediment Storage El: 534.9 Has Veg.Filter No Bottom Elevation: Bottom Elevation: 534.50 Proprietary System Maintenance Requirements How many devices are Click here to update O&M Contech Jellyfish? Manual Important operation and maintenance procedures: - The drainage area will be carefully managed to reduce the sediment load to the Snout. - The sedimentation chamber will be cleaned out whenever sediment depth exceeds half of the sump. The Jellyfish System will be inspected annually. Records of operation and maintenance will be kept in a known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. BMP element: Potential problem: How to remediate the problem: Entire BMP 'Trash/debris is present. 'Remove the trash/debris. Adjacent pavement (if Sediment is present on the pavement Sweep or vacuum the sediment as soon as possible. applicable) surface. Flow diversion structure The structure is clogged. Unclog the conveyance and dispose of any sediment offsite. The structure is damaged. Make any necessary repairs or replace if damage is too large for repair. StormFilter Cartridges Cartridges not performing as Replace cartridges per manufacturer's recommendations. designed-see Contech l&M document to determine if cartridge maintenance is required. Outlet device Clogging has occurred. Clean out the outlet device.Dispose of the sediment offsite. The outlet device is damaged Repair or replace the outlet device. Receiving water Erosion or other signs of damage Contact the local NCDEQ Regional Office. have occurred at the outlet. All other operation and maintenance activities should be in accordance with Contech's Jellyfish Inspection and Maintenance Procedures document.Any problems that are found shall be repaired immediately.The responsible party shall have received and understand Contech's Jellyfish Inspection and Maintenance Procedures document. ATTACH MANUFACTURER'S MAINTENANCE MANUAL FOR ALL PROPRIETARY DEVICES % \iiilikuoro • %O I & E GINEERED SOLUTI it ,... ..,... • . ,t \ ,„ ,. . --...., . , . ...,, , . , ‘ 0 ' . , . ) •2• . • .. ,, .,• , .. f . , f i, \ '.• . if . . l\ \ I• , , 1 0 , . Jellyfish ® Filter . e • . Stormwater Treatment . . i . . ;...._•....... .. .... _ ...-..-- - . ..„ .........ii....: _ _,..:_.:..;:„.... ...„....,_, ., . , . _ ,,: ,c__:.1,,•44,.... .....,..,,..„..._., _ .• .i-,.._,-wv.....voirp", . ,iit. . ..„..:4. ..,...,....-.. ‘„ _. ,_,,,A,„---,;‘,—.„,,,z _ , _ , ..-..-§,.:, A-,....-c-''.• - : r ' -A._ '.. lirk.,, -- • 2V.r-,1-_:..-.--S--- -.-:s-..:•77--_ - 1 • . ,',-- - . -- "X' . -- -,•Z .._.:.F.. 7, —----..,,-..,.-,z-1,-...-,--_--_-:.-..-..--. -'''''..,,_.-i,R•ii. •;..-0-.-.5 .- s't '•••• -4,. . — . - . __ , „ s •,.. C" • •-- ' ...:;' ' ... ... .1( , . . , .- • ,4 --•• -.• . —... . . ._ .. i •.4. • , -.0` ' . ',.''.-'i•t,.'t:.,...,----,,-•..:-:. . -. 4 --.1 --k•-CC;;:,wX444..-,_11„, , i • .. - • •••-' st,'•:::44- ,. ,... ., .. - 1 , The experts you need to solve stormwater hallengesyour � 11. , - , 4$ti. % !4 '1 d. , .)0 . 4 it / � �VII `d ' • ''� / :' Your Contech Team Contech is the leader in stormwater solutions, STORMWATER helping engineers,contractors and owners with CONSULTANT infrastructure and land development projects t ` . It's my job to recommend the best solution to meet throughout North America. permitting requirements. With our responsive team of stormwater experts, I STORMWATER local regulatory expertise and flexible solutions, 'at/IN DESIGN ENGINEER Contech is the trusted partner you can count on for i.„.,, lworkwith consultants to design I the best approved solution to stormwater management solutions. meet your project's needs. REGULATORY MANAGER a, -, I understand the local stormwater regulations and what solutions Is will be approved. i SALES ENGINEER 1 make sure our solutions • meet the needs of the contractor GP el during construction. Contech is your partner in stormwater management solutions 1m1111111 ' 11 m • •I. -- - 1l q i 1! .V J. 0 _, Nii Y.' i. r I ... . ,•..) Pc •- , i ' f t• ,''Y , � . • d �� Ifff •; }� ;117+y;„4 t (' + ia t WI 9q p (' -7 fet .I•il•I • } ar �' M • ! ' 1 +1 i1• a 4! a�� . { � ' I-- Y , • 1 1111 y • c 4 if O' ma � ~.• _ y^{- Setting new standards in Stormwater in efieldaellyfish Flaboer atory,as been ested in the field and laboratory,and has received ap teses sTreatment — Jellyfish° Filter stormwater regulatory omnumerous The Jellyfish Filter is a stormwater quality treatment technology featuring high flow pretreatment and membrane Jellyfish®Filter filtration in a compact stand-alone system.Jellyfish removes floatables,trash,oil,debris,TSS,fine silt-sized particles, and a high percentage of particulate-bound pollutants; including phosphorus, nitrogen, metals and hydrocarbons.The high surface area membrane cartridges,combined with up-flow hydraulics,frequent, passive backwashing,and rinseable/ reusable cartridges ensure long-lasting performance. C=:: NTECH@ ENGINEERED SOLUTIONS How the Jellyfish° Filter Treats Stormwater Tested in the field and laboratory... ■ Stormwater enters the Jellyfish through the inlet pipe and traps floating pollutants behind the maintenance access wall and below the cartridge deck. ■ Water is conveyed below the cartridge deck where a 411. separation skirt around the cartridges isolates oil,trash and debris outside the filtration zone. ■ Water is directed to the filtration zone and up through the top of the cartridge where it exits via the outlet pipe. ■ The membrane filters provide a very large surface area to effectively remove fine sand and silt-sized particles, and a high percentage of particulate-bound pollutants such as nitrogen,phosphorus,metals,and hydrocarbons while ensuring long-lasting treatment. ■ As influent flow subsides,the water in the backwash pool flows back into the lower chamber.This passive backwash extends cartridge life. ■ The draindown cartridge(s)located outside the backwash pool enables water levels to balance. Jellyfish'Filter Standard Configuration Learn More: www.ContechES.com/jellyfish 1 Pretreat bioretention or 111113°).1.7. infiltration with Jellyfish to extend service life. Setting new standards in Stormwater Treatment O U STEPS 41) O VI MAY • MAY VARY FLOW � O 00H OO Jellyfish® Filter Performance O O O F< Testing Results 1 cw rIt, . s • APPLICATION TIPS - - • The Peak Diversion Jellyfish provides treatment and high- • .4.1.0000/ flow bypass in one structure, ' eliminating the need for a / separate bypass structure. C \ J. • LID and GI are complemented J by filtration solutions,as they ill� help keep sites free from fine sediments that can impede performance,remove 10 unsightly trash,and provide a . - -_, ___, /0 410 , : ... single point of maintenance. • Selecting a filter with a long maintenance cycle and low maintenance cost will result in healthy waterways and •happy property owners. z. ; i The pleated tentacles of the Jellyfish®Filter provide a large surface area for pollutant removal. POLLUTANT OF CONCERN %REMOVAL . . .`r`- Total Trash 99% 1 i 114' ' Total Suspended Solids(TSS) 89% - Total Phosphorus(TP) 59% Total Nitrogen(TN) 51% Sources: Total Copper(TCu) > 50% TARP II Field Study-2012 JF 4-2-1 Configuration MRDCFIoatables Testing-2008JF6-6-1 Configuration Total Zinc(TZn) > 50% =:1►C NTECH ENGINEERED SOLUTIONS Jellyfish° Filter Features and Benefits FEATURE BENEFITS High surface area membrane filtration Low flux rate promotes cake filtration and slows membrane occlusion High design treatment flow rate per cartridge(up to 80 Compact system with a small footprint,lower construction cost gpm(5 Us)) Low driving head(typically 18 inches or less(457 mm)) Design flexibility,lower construction cost Lightweight cartridges with passive backwash Easy maintenance and low life-cycle cost The Jellyfish Filter can be �,� configured in a manhole, catch basin, or vault. Select Jellyfish° Filter Certifications and Verifications The Jellyfish Filter has been reviewed by numerous state and federal programs,including: • Washington State Department of Ecology(TAPE)GULD—BASIC, � • , Phosphorus I • Virginia Department of Environmental Quality(VA DEQ) • Texas Commission of Environmental Quality(TCEQ) • Aft. • • Canada ISO 14034 Environmental Management—Environmental • ✓ • Technology Verification(ETV) • • Philadelphia Water District(PWD) • • Maryland Department of the Environment(MD DOE) Field tested and performance verified O U STEPS 41)/7' O (LOCATION MAY VARY• �� O OOH FLOW v OO . Jellyfish® Filter Configurations O O O F< 1 cw Multiple system configurations to optimize your site.... The Jellyfish Filter can be manufactured in a variety of configurations:manhole,catch basin�40 MIN vault,fiberglass tank,or custom configurations. Typically, 18 inches(457 mm)of driving head is designed into the system.For low drop sites,the designed driving head can be less. MID 411. lit-_-....,,,- ..- .... Manhole Vault - 3. I lick . , 1 ,,...- Oa Curb Inlet I II It Op ' Grated Inlet Ill Ill Jellyfish° Filter Maintenance � , .� • Jellyfish Filter cartridges are light weight and reusable `` • Maintenance of the filter cartridges is performed by removing, . rinsing and reusing the cartridge tentacles. I , 'if. I • Vacuum extraction of captured pollutants in the sump is 1hl ,- recommended at the same time. i • Full cartridge replacement intervals differ by site due to varying r M A. pollutant loading and type,and maintenance frequency. " Replacement is anticipated every 2-5 years. • Contech®has created a network of Certified Maintenance Providers to provide maintenance on stormwater BMP's. The Jellyfish®Filter tentacle is light and easy to clean. C=:: NTECH ENGINEERED SOLUTIONS A partner you can rel o 1.._.:77 _ _ •,..,..,,.,,. .a. IF' ._ t ..• �,04 \� c� n _ .� A ear 4 , t!k i ..r!'A .�_ t t, mi til , ,..f _ } '14ftb'--4\l'''''' 1 • r ti c . a- ,'o �*k>s v s pi " -:-. 6'" v'�\ �t< }i i - - '`11.erm -__If iv,--re .L x. { -�t j b �. '- - 17E -4: �o ;+irrind r:\ ' `# >.r� _ } '.x w-$a44.* I. •A �'- a v r��ro - .`_- _ .may .i7. rFs 7_, '",'� ;� -_• i`M�..y,X+h-�f 7h a� ', 'x\ °Ps`..<4',S_,�q,..r, tow,, L , t s -, -,..-r - _ —T; _ z o y. :^'L ^•' ... M'r , • '.: •w"rr ._ 4� *' T7r'r. r.3"-_ -"- _ f_ °'£- 3 _- t i.-- V/', _ •'' ' . - STORMWATER , PIPE STRUCTURES SOLUTIONS SOLUTIONS IT9111 SOLUTIONS Few companies offer the wide range of high- THE CONTECH WAY Contech®Engineered Solutions provides innovative,cost-effective quality stormwater resources you can find with site solutions to engineers,contractors,and developers on projects us—state-of-the-art products,decades of across North America.Our portfolio includes bridges,drainage, expertise,and all the maintenance support you erosion control,retaining wall,sanitary sewer and stormwater management products. need to operate your system cost-effectively. TAKE THE NEXT STEP For more information:www.ContechES.com NOTHING IN THIS CATALOG SHOULD BE CONSTRUED AS A WARRANTY.APPLICATIONS C I�/i N T E C H SUGGESTED HEREIN ARE DESCRIBED ONLY TO HELP READERS MAKE THEIR OWN EVALUATIONS AND DECISIONS,AND ARE NEITHER GUARANTEES NOR WARRANTIES OF SUITABILITY FOR ANY ENGINEERED SOLUTIONS APPLICATION.CONTECH MAKES NO WARRANTY WHATSOEVER,EXPRESS OR IMPLIED,RELATED TO THE APPLICATIONS,MATERIALS,COATINGS,OR PRODUCTS DISCUSSED HEREIN.ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR ANY II MOO PARTICULAR PURPOSE ARE DISCLAIMED BY CONTECH.SEE CONTECH'S CONDITIONS OF SALE Get social with us: (AVAILABLE AT W W W.CONTECHES.COM/COS)FOR MORE INFORMATION. 800-338-1122 I www.Contech ES.com ®2021 Contech Engineered Solutions LLC,a QUIKRETE Company All Rights Reserved.Printed in the USA.