Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0037287_More Information (Received)_20240723
Initial Review Reviewer nathaniel.thorn burg Is this submittal an application? (Excluding additional information.) * Yes No If not an application what is the submittal type?* Annual Report Residual Annual Report Additional Information Other Permit Number (IR) * W00037287 Applicant/Permittee Pluris Hampstead, LLC Email Notifications Does this need review by the hydrogeologist? * Yes No Regional Office CO Reviewer Admin Reviewer Submittal Form Project Contact Information Please provide information on the person to be contacted by NDB Staff regarding electronic submittal, confirmation of receipt, and other correspondence. ......................................................................................................................................................................................................................................................................................... ... ... ... ... ... .. ... ... ... ... .. Name* Michael C Gallant Email Address* gallantmc@yahoo.com Project Information ......................... Application/Document Type* New (Fee Required) Modification - Major (Fee Required) Renewal with Major Modification (Fee Required) Annual Report Additional Information Other Phone Number* 9104481046 Modification - Minor Renewal GW-59, NDMR, NDMLR, NDAR-1, N DAR-2 Residual Annual Report Change of Ownership We no longer accept these monitoring reports through this portal. Please click on the link below and it will take you to the correct form. https://edoes.deq.nc.gov/Forms/NonDischarge_Monitoring_Report Permit Type:* Wastewater Irrigation High -Rate Infiltration Other Wastewater Reclaimed Water Closed -Loop Recycle Residuals Single -Family Residence Wastewater Other Irrigation Permit Number: * WQ0037287 Has Current Existing permit number Applicant/Permittee Address* PO Box 297 Hampstead, NC 28443 Facility Name* Pluris Hampstead WWTP Please provide comments/notes on your current submittal below. Zachary, I have uploaded the revised plans and the agreement with the recording notice from Pender RoD. Please call or email with anything else and Thanks! At this time, paper copies are no longer required. If you have any questions about what is required, please contact Nathaniel Thornburg at nathaniel.thornburg@ncdenr.gov. Please attach all information required or requested for this submittal to be reviewed here. (Application Form, Engineering Plans, Specifications, Calculations, Etc.) Pluris Hampstead Response to Email Comments 7-23- 36.84M6 2024.pdf Upload only 1 PDF document (less than 250 MB). Multiple documents must be combined into one PDF file unless file is larger than upload limit. * By checking this box, I acknowledge that I understand the application will not be accepted for pre -review until the fee (if required) has been received by the Non -Discharge Branch. Application fees must be submitted by check or money order and made payable to the North Carolina Department of Environmental Quality (NCDEQ). I also confirm that the uploaded document is a single PDF with all parts of the application in correct order (as specified by the application). Mail payment to: NCDEQ — Division of Water Resources Attn: Non -Discharge Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Signature twi l"WI&LIffflll"r Submission Date 7/23/2024 PROJECTNAME. PLURIS HAMPSTEAD WWTF EXPANSION APPLICANT/OWNER: PLURIS HAMPSTEAD, LLC REQUIRED PERMITS: ZONING APPROVAL PENDER COUNTY PO BOX 297 NPDES/NON-DISCHARGE PERMIT (MOD NC0089524)-NCDEQ HAMPSTEAD, NC 28445 SOIL EROSION AND SEDIMENT CONTROL - NCDEQ-DEMLR (214) 220-3412 LOW DENSITY STORM WATER PLAN (MOD SW8 140715) - MAURICE W. GALLARDA, PE NCDEQ-DEMLR MANAGING MEMBER MGALLARDA@PLURISUSA.COM BUILDING SETBACKS PER PLAN MICHAEL C. GALLANT, PE BUILDINGS TO BE CONSTRUCTED PROPOSED CONTROL BUILDING FOR NEW PLANT MICHAEL C. GALLANT, PE, PA 1840 SF, 1 STORY PO BOX 4039 SURF CITY, NC 28445 PROPOSED MECHANICS BUILDING (910) 448-1046 1 STORY GALLANTMC@YAHOO.COM BRIEF PROJECT DESCRIPTION THIS PROJECT PROPOSES THE CONSTRUCTION OF A NCPLS OF RECORD: MICHAEL UNDERWOOD AND ASSOCIATES 500,000 GPD MBR WAST TREATMENT PLANT ON THE 102 CINEMA DRIVE, SUITE C SAME TRACT AS THE EXISTING PLURIS HAMPSTEAD WWTF. WILMINGTON, NC 28403 THIS PLANT WILL UTILIZE THE EXISTING HIGH RATE 910-815-0650 INFILTRATION BASINS AND DISPOSAL INFRASTRUCTURE THAT THE EXISTING PLANT USES. THIS EXPANSION WILL DATUM: NAD 83 NC STATE PLANE BRING THE TOTAL TREATMENT CAPACITY OF THE FACILITY TO 1,000,000 GALLONS PER DAY. PROJECT START DATE. AUGUST 2024 TARGET COMPLETION: MARCH OF 2025 EXISTING USE. WASTEWATER TREATMENT PLANT UTILITY PROVIDERS: WATER - EXISTING PRIVATE WELL PROPOSED USE. WASTEWATER TREATMENT PLANT (PCU WATER NOT CURRENTLY AVAILABLE) SEWER - WASTEWATER TO BE DIRECTED TO THE PROPOSED PROPERTY PIN 3271-17-1644-0000 PLANT PROPERTY ADDRESS 9795 Hogans Trail, Hampstead, NC 28443 PLURIS HAMPSTEAD, LLC ZONING PD PO BOX 297 NAICS CODE 221320 HAMPSTEAD, NC 28445 DEED REFERENCE. 4099/91 888-758-7471 ELECTRIC UTILITY PROVIDER DUKE ENERGY PROGRESS 1451 MILITARY CUT OFF WILMINGTON, NC 28403 800-452-2777 LATTITUDEAND LONGITUDE: LATTITUDE: 34' 20' 34.70" LONGITUDE: -77° 46' 16.59" PARKING CALCULATIONS/TRAFFIC: TOTAL BLDG. SF = 8,120 (EX. PLANT = 2,688 SF, TOTAL PROJECT PROPERTYAREA: 28.77 ACRES PROPO. PLANT =1,932 SF, MECH. BLDG. = 3,500 SF) 1 SPACE PER 1000 SF REQ. = 8.1 SPACES REQ. TOTAL AREA TO BE DISTURBED: 3.6 ACRES EX. SPACES 5 PROP. SPACES 5 TOTAL AREA IN USCOE WETLANDS: 8.40 ACRES (USCOE DELINEATION 2014) TOTAL PROV. 10 WETLANDS TO BE DISTURBED: 0 ACRES TOTAL AREA IN SURFACE WATERS: 0 ACRES RECEIVING STREAM INFORMATION: NAME: UT OF ISLAND CREEK INDEX: 18-74-27 (ISLAND CREEK) CLASSIFICATION C:SW FLOOD ZONE FIRM PANEL 3271 Effective date: 2/16/07 (3270327100J) STORMWA TER PROJECT DENSITY. • LOW DENSITY (>24% BUA) EX PERMIT SW8 140715 FIRE DISTRIC AND MISC. TOPSAIL TOWNSHIP/SCOTTS HILL FIRE DISTRICT THIS PROPERTY IS NOT IN A VOLUNTARY AG DISTRICT (VAD) THIS PROPERTY DO NOT CONTAIN ANY AREAS ON THE NATIONAL REGISTER OF HISTORIC PLACES THIS PROPERTY DOES NOT FALL WITHIN A FLIGHT PATH OVERLAY AREA NOTE: THERE ARE NO SURFACE WATERS, WETLANDS,, REGULATORY FLOOD ZONES OR PROTECTED RIPARIAN BUFFERS TO BE DISTURBED ON THE PLANT SITE. PENDER COUNTY SUP 11070 (PREVIOUSLY APPROVED) STATES THE FOLLOWING CONDITIONS: NOTE: PARKING WILL COMPLY WITH ARTCLE 7.10.5.D OF THE PENDER COUNTY UDO ALL PARKING SPACES WILL HAVE A BARRIER OR EDGING AROUND THE PARKING AREA AND EACH SPACE ESTIMATED AM PEAK HOUR TRIPS 10 ESTIMATED PM PEAK HOUR TRIPS 10 AVREAGE NUMBER OF EMPLOYEES ON SITE AT ANYTIME = 3 BUFFERS: FRONTAGE ALONG HOGANS TRAIL - 30' WIDE TYPE "A" SIDE PROP. LINES - 25' WIDE TYPE "C" 1. County review of expanded service areas shall be required to demonstrate consistency with the goals and priorities of the comprehensive plan. A consistency determination should be issued by the Planning and Community Development Department prior to application being made to the State Utilities Commission. This may be in the form of staff approval of a specific project or Board (Planning Board/Board of County Commissioners) approval, dependent upon review criteria outlined in the Pender County Unified Development Ordinance (as amended). 2. The sewage treatment facility and associated infrastructure shall be built in accordance with all applicable local, state, and federal regulations. The treatment facility and associated infrastructure should be designed and constructed for the conversion of the system to public ownership, operation and maintenance should the system be accepted by the County. 3. Service areas requested by the applicant to the Public Utilities Commission should be non-exclusive service areas to allow for Pender County Utilities to provide service along the applicant's force main locations. 4. No junk, debris trash or inoperable vehicles, recycled or salvaged materials shall be stored on the site outside a completely enclosed building. 5. No project activity shall commence on the site including clearing and grading until a Final Zoning Permit has been issued. 6. No permanent personnel occupancy on -site will be allowed. 7. All operations must follow federal, state, and local standards, regulations, ordinances, permits, statutes, and/or laws. PLURIS HAMPSTEAD WWTF PLANT EXPANSION HAMPSTEAD, NIC PENDER COUNTY Sheet List Table Sheet Sheet Title Number CO.0 MCG STANDARDS COVER SHEET - CLO COVER PAGE C1.0 MCG PLURIS HAMPSTEAD PROJECT MASTER - PROCESS FLOW DIAGRAM CL I HYDR PROFILE C1.2 HYDR PROFILE C1.3 Equipment Spread Sheet CIA Equipment Spread Sheet C2.0 OVERALL SP C2.1 PLANT SP C2.2 GRADING PLAN C2.3 YARD PIPING C2.4 PROFILE 1 C2.5 PROFILE 2 C2.6 PROFILE 3 C2.7 PROFILE 4 C2.8 YARD PIPING DETAILS C3.0 TANK STRUCTURE PLAN C3.1 TANK SECTION A C3.2 REINFORCEMENT DETAILS C3.3 3.3 CONCRETE NOTES C3.4 CONTROL BUILDING PLAN C3.5 CONTROL BUILDING SECTION-TYP WALL C3.6 CONTROL BUILDING ELEVATIONS C4.0 FINE SCREENS C4.1 FINE SCREENS C4.2 FINE SCREENS C5.0 IR-FF RAS C5.1 IR-FF RAS SA C6.0 PRE AERATION PLAN C6.1 PRE AERATION SECT C7.0 MBR PLAN C7.1 MBR SECTIONS C8.0 WW LIFT STATION C9.0 WAS -RESCREEN C10.0 PROCESS CONTROL C11.0 NCGO1 PAGES C11.1 SEEDING CHART AND EC STANDARD DETAILS C11.2 EROSION CONTROL AND STORMWATER CALCULATIONS APP 1 APPENDIX 1 ENVIROMIX P AND ID DRAWING LIST HNC-I-01 COVER SHEET HNC-I-02 SYMBOLS & LEGEND I HNC-I-03 SYMBOLS & LEGEND 2 HNC-I-04 EQUALIZATION BASIN HNC-I-05 FINE SCREENS HNC-I-06 PRE -ANOXIC BASIN 01 HNC-I-07 PRE -AERATION BASIN 01 HNC-I-08 PRE -AERATION BASIN 02 HNC-I-09 FEED FORWARD / INTERNAL RECYCLE PUMPS HNC-I-10 POST -ANOXIC BASIN 01 HNC -I -I I MEMBRANE BIOREACTOR BASIN 01 HNC-I-12 MEMBRANE BIOREACTOR BASIN 02 HNC-I-13 MBR PERMEATE PUMPS HNC-I-14 WASTE ACTIVATED SLUDGE PUMPS HNC-I-15 MEMBRANE BASIN AND PROCESS AIR BLOWERS HNC-I-16 CLEAN -IN -PLACE HNC-I-17 CHEMICAL (ALUM & NaOH) INJECTION HNC-I-18 CHEMICAL (CARBON & PERACTIC ACID) INJECTION HNC-I-19 WASHWATER LIFT STATION VICINITY MAP NTS LINE LEGEND LINE TYPE EX. PROPERTY LINE LOT LINE RIGHT OF WAY ROAD CENTERLINE EDGE OF PAVEMENT BACK OF CURB EXISTING TOPO PROPOSED TOPO LIMITS OF DISTURBANCE SEDIMENT FENCE WETLANDS SS GRAVITY MAIN STORM DRAIN MAIN SS FORCE MAIN WATER LINE SETBACK LINE ACCESS/UTILITY/DRAINAGE EASEMENT SYMBOL LEGEND SYMBOL LOT NUMBER FIRE HYDRANT ASSEMBLY SS MANHOLE STORM DRAIN MANHOLE STORM DRAIN CURB INLET STORM DRAIN CATCH BASIN BEARING AND DISTANCE SPOT ELEVATION SHEET FLOW ARROW INLET PROTECTION CHECK DAM ENERGY DISSAPATER SKIMMER BASIN FLARED END SECTION AIR RELIEF VALVE GATE VALVE CHECK VALVE TEMPORARY BLOW OFF EXAMPLE affivi -30- - 30 LOD SF WET FM W Know what's below. Call before you dig. �- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRIUCTION a fCAP,,"/i 9572 cL C G 6/1 /24 EXAMPLE O \No. Revision/Issue Date/ 0 o / \ MICHAEL C. GALLANT, PE, PA PO BOX 4039 N 90°00'00" 58.99' z SURF CITY, NC 28445 910-448-1046 X??? O gallantmc@yahoo.com --4.43% NC FIRM#: C-1989 HIP F. N �> < PROJECT: ®ED G PLURIS HAMPSTEAD VWV-FP 0 EXPANSION PLANT a O CLIENT: o L.L PLURIS HAMPSTEAD, LLC HOGANS TRAIL e _ HAMPSTEAD, NC 28443 e BO V /Project Sheet Date 6/1 /24 Scale 1 = 50 r� r C000 PLURIS HAMPSTEAD WWTF PROCESS FLOW DIAGRAM IQ= I MGD (CLOUDED ITEMS ARE EXISTING) FINE SCREENS (2) AERATIONv PREANOXIC VOL = .052 MG 2.5Q MIXING PRE AERATION TANK I 2 25Q 2.25Q VOL = .063 MG AERATION AL&UM ALK POST ANOXIC TANK 2.5Q VOL = .040 MG MIXING 2Q RAS RECIRCULATION 2.5Q 1.25Q VOL = 035 MG AERATION MRR ZONE I VOL = .035 MG AERATION = 101 General Notes 1 IW- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/3/24 No. Revision/Issue Date/ MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 000, PROJECT: PLURIS HAMPSTEAD VWVfF PLANT EXPANSION CLIENT: PLURIS HAMPSTEAD, LLC HOGANS TRAIL HAMPSTEAD, NC 28443 Sheet Date C 1 • 0 6/3/24 Scale N TS 60 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 EL. 66.41EOUAL/ZATION PUMP OPERA / G HEAD) MAX EL. 51.87 (FREE SURFACE) EL. 4780 (FREE SURFACE) EXISTING EQUALIZATION BASIN TANK KIP1.5.0.87 NZX/41,1 i,ti7 AVF W1 47RO l7 TANK 1NV 42.0 7W EL. 54.73 (FREE SURFACE) PIPED GRAVITY FLOW WL 49.0 /FREE SURFACE) ROTARY DRUM SCREENS SCREEN INLET INVERT 54.73 SLIDEGATE \/ TANK RIM 51.0 I 'g WL 490 C7 .D D i •. 1 TANK INV 3 /.0 PAX-01 PRE -ANOXIC BASIN EL. 46.5 (FREE SURFACE) COMMON WALL TANK TANK RIMS 1.0 WL 46.5 q TANK INV 3 /.0 PA-01,02 PRE -AERATION BASIN EL. 62.60 FEED FORWARD PUMP OPERAT NG HEAD) PIPED FM FLOW SLIDE GATE EL. 49.0 (FREE SURFACE) TANK R1111 51.0 _ WL 49.0 C7 D. TANK INV 3/.0 , AXP-01 POST ANOXIC BASIN EL. 48.0 (FREE SURFACE) TANK RIN 51.0 p WL 48.0 TANK INV 3 /.0 MB-01,02 MBR BASIN EL. 141.37 (PERMEATE PUMP OPERATING HEAD) R CONTROL SURFACE) 60 _Vj_ 54 5' L 50 40 4` v l7 WL 45.0 � 4L - � 40 30 D 3'_ 34 E D... 3z- WASH WATER LIFT STATION 30 '3 L �3 L l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION `11111111111///// �N CARO"** S L 2 72 GN /11111110% 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 `PROJECT: \ PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION W CLIENT: J PLURIS HAMPSTEAD, LLC H PO BOX 297 O HAMPSTEAD, NC 28443 ry >/ U O#Project Sheet \ J Q Date . 6/5/24 ry Scale FLOW OL 60 ✓ 4 r� ✓ L r0 A 46 , 42 , 4v 38 D 3v PIPED GRAVITY FLOW EL. 45.0 (FREE SURFACE) Q (D WL 45.0 HRIP BERM 450 / I r \ 34 ,L17 WASH WATER LIFT STATION 30 �8 L GRAVITY FLOW EL. 43.0 HRIP BERM 45.0 j MAX WATER ELE 43.0 SURPLUS GW IMP. \ / BERM ELE 4 /.0 \ HRIP BOTTOM ELE 38.0 / GWL UNDERDRAIN INV 38.5 HIGH RATE INFILTRATION BASIN ACYNTIIVr ) GROUND WATER LOWERING UNDER DRAIN AT 50' SETBACK INLET FROM SWALE ELE 38.5 EL. 38.5 (MAX FREE SURFACE) SURPLUS GROUND WATER IMPOUNDMENT 0 MAX WL 38.5 INV 34.9/� IMP. BOTTOM ELE 30.0 SURPLUS GROUND WATER IMPOUNDMENT AND DISHARGE PUMP STATION FrlsTWI-- EL. 17750 GW HYDROPNEUMAT/C TANK MA HEAD) // N\ EL. 13 /.50 (GW HYDROPNEUMATIC TANK MlN HEAD) FM FLOW GROUNDWATER DISCHARGE H YDR OPNEUMA TIC TANK (EXISTING) 0 %7 WL 38.5 D U� GROUNDWATER DISCHARGE LIFT STATION NOTE REUSE IRRIGATION BY THIRD PARTY (BLAKE FARM POND) NOT SHOWN) / lNV 16.0 NPDES DISCHARGE 00I (EXSITING) AND 002 (PROPOSED) 60 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ,p"',a fCARn"", 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 `PROJECT: \ PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION W CLIENT: J PLURIS HAMPSTEAD, LLC H PO BOX 297 O HAMPSTEAD, NC 28443 ry >/ U O#Project Sheet \ J Date C1m2 Q 6/5/24 ry Scale Model/ Drawing Sheet P and ID Sheet Specification Specification Name Tag # Type Manufacturer Motor HP Voltage QTY Supplier Specification Number Number Page Appendix HEADWORKS 2-mm Internally FedDrum Fine Screen IS-01 IS-02 CleanTek RS24 0.5 460 VAC 2 Kubota C4.0-C4.2 5 70 V - B SCP-220 Shaftless Compactor CP-01 CleanTek Screw 3 460 VAC 1 Kubota C4.0-C4.2 5 78 V - C Cl Gate Valve Wheel Screen Isolation Valves GV - 101, GV - 102 2 Operator Meuller or Equiv. Contractor/Owner C4.1, C4.2 5 46 IV - 3g Screen/Compactor Washwater 1" Sched 80 Ball Iso Valves BV-101 BV-201 BV-301 Valve 3 Contractor/Owner C4.1 5 70178 V - B,C Screen/Compactor Washwater 110 VAC SS Solenoid Actuated Valves SV-101 SV-201 SV-301 1" Actuated Valve Valve 110 VAC 3 Contractor/Owner C4.1 5 70 V - B,C Simplex Grinder Station 36" dia x 72" FRP Meyers 1 Contractor/Owner C4.1 5 49 IV-J Grinder Pump Centrifugal Meyers VS20-20-21 2 220 VAC 1 Duty/ 1 Shelf Spare Contractor/Owner C4.1 5 49 IV-J EQ BASIN EQ Level Switch LSH030101 LSL030101 Float Conery 2900 Series B3 120 VAC 2 Kubota C2.1 4 120 V - J EQ Level Transmitter LT030101 LE030101 Hydrostatic Endress Hauser Waterpilot FMX21 120 VAC 1 Kubota C2.1 4 120 V - J EQ Pumps P-03-01 P-03-02 Submersible Flyght or Equiv. NP-3102.060 5 460 VAC 2 Contractor/Owner C2.1 4 24 IV - 1e 30-31 Wafer Series EQ Isolation Valves BV0301 BV0302 Buterfly Valve Bray or Equiv. 1 Handle w Notch 2 Plate Contractor/Owner C2.1 4 43 IV - 3d Cl Swing Check EQ Check Valves 2 CV0301 CV0302 Valve Meuller or Equiv. Gravity Contractor/Owner C2.1 4 44 IV - 3d EQ Flow Meter FIT030101 FE030101 Electromagnetic Endress & Hauser Promag W 400 120 VAC 1 Kubota C2.1 4 120 V - J PRE ANOXIC BASIN Pre AX Level Switches LSH060101 LSL060101 Float Conery 2900 Series B3 120 VAC 2 Kubota C10.0 6 120 V - J Pre Ax Mixing Envromix Contractor/Owner C5.0, C5.1 6 24 IV - 2 PRE AIR BASINS PA Level Switch LSH080101 LSL080101 Float Conery 2900 Series B3 120 VAC 4 Kubota C10.0 7,8 120 V - J PA Level Transmitter LT080101 LE080101 Hydrostatic Endress Hauser Waterpilot FMX21 2 Kubota C10.0 7,8 120 V - J PA pH Probe AE080101 AE080201 Digital HACH pHD sc 120 VAC 2 Kubota C10.0 7,8 120 V - J PA DO Probe AE080101 AE080201 Digital HACH LDO Model 2 120 VAC 2 Kubota C10.0 7,8 120 V - J PA pH/DO Transmitter AIT080101 AIT080201 Digital HACH SC4500 120 VAC 2 Kubota C10.0 7,8 120 V - J Fine Bubble Diffusers FB-08-01 FB-08-02 1 Kubota C6.0, C6.1 7,8 101 V - G POST ANOXIC BASIN Post AX Level Switches LSH090101 LSL090101 Float Conery 2900 Series B3 120 VAC 2 Kubota C10.0 10 120 V - J Post Ax Mixing Envromix Contractor/Owner C5.0, C5.1 10 101 IV - 2 MBR BASINS MBR Level Switches LSL100101 LSL100102 Float Conery 2900 Series B3 120 VAC 2 Kubota C10.0 11,12 120 V - J 0.4 Micron Flat Plate Membrane Cassettes MB-01 MB-02 Membrane Cassettes Kubota SP -65 8 Kubota C7.0, C7.1 11,12 50 V - A Act.: Bray S70-006 Cassette Permeate Valves BF-1005A,B BF-1006A,B BF-1007A,B BF1008A,B ON/OFF Ball Bray ON/OFF BF-1009A,B BF1010A,B BF-1011A,B BF1012A,B Vlv.: Asahi Type 21 Kubota C7.0, C7.1 11,12 117 V - 1 Act.: Bray S70-006 Cassette Air Valves BF-1001A,B BF-1002A,B BF1003A,B BF1004A,B ON/OFF Ball Bray ON/OFF Vlv.: Asahi Type 21 Kubota C7.0, C7.1 11,12 117 V - 1 PERMEATE SYSTEM Self -Priming PRMT Pumps P-13-01 P-13-02 P-13-03 Centrifugal / Rotary Boerger CL 390 10 460 VAC 3 Lobe Kubota C7.0, C7.1 13 90 V - E Act.: Bray S70-006 PRMT Vent Valve BV-1001A,B ON/OFF Ball Bray ON/OFF 120 VAC 2 Vlv.: Asahi Type 21 Kubota C7.0, C7.1 13 117 V - 1 Act.: Bray S70-006 FCV130101 ZSC130101 CV130101 HS130101 PRMT Flow Control Valves Modulating Butterfly Bray Modulating 120 VAC 2 FCV130201 ZSC130201 CV130201 HS130201 VIv.:Bray S31 Kubota C7.0, C7.1 13 117 V - 1 PRMT Pump Pressure Transmitters PT130101 PT130201 Diaphragm Endress & Hauser Cerabar PMC21 2 Kubota C7.0, C7.1 13 120 V - J FIT130101 FE130101 FIT130201 PRMT Flow Meter FE130201 Electromagnetic Endress & Hauser Promag W 400 120 VAC 2 Kubota C7.0, C7.1 13 120 V - J PRMT Turbidity Meter AE130101 AE130201 Laser HACH TU5300sc 120 VAC 1 Kubota C7.0, C7.1 13 120 V - J PRMT Turbidity Transmitter AIT130101 AIT130201 HACH SC4500 120 VAC 1 Kubota C7.0, C7.1 13 120 V - J 30-31 Wafer Series BF-1301 BF-1302 BF-1303 BF13-4 BF-1305 BF-1306 BF- PRMT Isolation Valves Buterfly Valve Bray or Equiv. 1 Handle w Notch 6 1307, BF13-08, BF-1311, BF-1312 Plate Contractor/Owner C7.0, C7.1 13 43 IV - 3d PRMT Check Valves CV-1301 CV-1302 CV-1303 Cl Check Swing Valve Meuller or Equiv. Gravity 3 Contractor/Owner C7.0, C7.1 13 44 IV - 3f PRMT Suction Pressure Gage PG-130101 PG-130201 PG-130301 McDaniel MPB/SCB 3 Contractor/Owner C7.0, C7.1 13 47 IV - 4 Permeate Discharge Pressure Gage PG-130201 PG-130202 PG-130302 McDaniel MPB/SCU-GF 3 Contractor/Owner C7.0, C7.1 13 47 IV - 4 RAS PUMPING SYSTEM Self-Priming IR Pumps P-11-01 P-11-02 P-11-03 P-11-04 Centrifugal Gorman Rupp T10A60S-B— 10 460 VAC 4 Kubota C5.0, C5.1 9 83 V - D FIT110101 FE110101 FIT110201 IR Flow Meters FE110201 FIT120102 FE120102 Electromagnetic Endress & Hauser Promag W 400 120 VAC 4 FIT120201 FE120201 Kubota C5.0, C5.1 9 120 V - J Act.: Bray S70-006 FCV120101 ZSC120101 FCV110101 Modulating IR/FF Flow Control Valves ZSC110101 FCV120201 ZSC120201 Modulating Plug Bray 120 VAC 4 Vlv.:Milliken ECC FCV110201 ZSC110201 Plug Kubota C5.0, C5.1 9 117 V - 1 PV -1101 PV-1102 PV-1103 PV-1104 PV- Cl Gate Valve Wheel IR/FF Isolation Valves 8 1105 PV-1106 PV-1107 PV-1108 Operator Meuller or Equiv. Contractor/Owner C5.0, C5.1 9 46 IV - 3f Cl Swing Check IR/FF Check Valves Arm and Weight 4 CV-1101 CV-1102 CV-1103 CV-1104 Valve Meuller or Equiv. Contractor/Owner C5.0, C5.1 9 44 IV - 3g IR/FF Pressure Gages PG-110101 PG-110102 PG-110201 PG-110202 McDaniel MPB/SCA 4 Contractor/Owner C5.0, C5.1 9 47 IV - 4 l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, INC 28445 910-448-1046 gallantmc@yahoo.com w ILL] INC FIRM#: C-1989 U) Q` PROJECT: W PLURIS HAMPSTEAD VWVfP � .5 MGD MBR EXPANSION U) CLIENT: I- PLURIS HAMPSTEAD, LLC z PO BOX 297 W HAMPSTEAD, NC 28443 Project Sheet W Date 6/5/24 C13 z Scale J Model/ Drawing Sheet P and ID Sheet Specification Specification Name Tag # Type Manufacturer Motor HP Voltage CITY Supplier Specification Number Number Page Appendix WAS/RESCREENING PUMPING SYSTEM Self -Priming WAS Pumps P-17-01 Centrifugal / Rotary Gorman Rupp T2D60S-B /F- 3 460 VAC 2 P-17-02 Lobe Kubota C9.0 14 83 V - D WAS Flow Meter FIT170101 FE170101 Electromagnetic Endress & Hauser Promag W 400 120 VAC 2 Kubota C9.0 14 120 V - J Act.: Bray S70-006 WAS Flow Control Valve XV170101 ZS0170101 ON/OFF Plug Bray Modulating 120 VAC 2 ZSC170101 Vlv.:Milliken ECC Plug Kubota C9.0 14 117 V - I Heyward or True Union PVC WAS Iolation Valves BV-1702 BV-1703 BV-1704 BV-1705 2 Equivalent Ball Valve Contractor/Owner C9.0 14 42 IV - 3b WAS Check Valves CV-1701 CV-1702 Cl Swing Check Mueller Gravity Check 2 Contractor/Owner C9.0 14 43 IV - 3f WAS Discharge Pressure Gage PG-170101 PG-170201 McDaniel MPB/SCB 2 Contractor/Owner C9.0 47 IV-4 PRE AIR PROCESS AND MBR SCOUR BLOWERS MBR Blowers MOT140101 MOT140201 Positive Displacement Kaeser DB 166 C 30 460 VAC 3 MOT140301 Kubota C7.0, C7.1 15 108 V - H MBR Blower Temperature TSH140101 TSH140102 TSH140201 Switch TSH 140202 TSH 140301 TSH 140302 With Blower Kaeser 120 VAC 3 Ku bota C7.0, C7.1 15 120 V - J MBR Blower Flow Meter FIT140101 FE140101 FIT140201 Thermal Mass Endress & Hauser t-mass 1 500 120 VAC 3 FE140201 Kubota C7.0, C7.1 15 120 V - J MBR Blower Pressure Transmitter PIT140101 PIT140201 Diaphragm Endress & Hauser Cerabar PMP51B 120 VAC 3 Kubota C7.0, C7.1 15 120 V - H PA Blower MOT150101 MOT150201 Positive Displacement Kaeser CB 131 C 20 460 VAC 2 Kubota C6.0, C6.1 15 108 V - J PA Blower Temperature Switch TSH140201 TSH140202 TSH150201 With Blower Kaeser 120 VAC 2 TSH150202 Kubota C6.0, C6.1 15 120 V - J PA Blower Pressure Transmitter PIT150101 PIT150201 Diaphragm Endress & Hauser Cerabar PMP51B 120 VAC 2 Kubota C6.0, C6.1 15 120 V - J 30-31 Wafer Series Blower Isolation Valves BF-1401 BF-1402 BF-1403 BF-1404 BF-1501 BF-1502 Buterfly Valve Bray or Equiv. 1 Handle w Notch 8 BF1503 BF-1504 Plate Contractor/Owner C6.0 - C7.1 15 43 IV - 3d MBR CIP SYSTEM CIP Solution Injection Pump P-16-01 Self -Priming Finish Thompson 5-15 gpm SFV40-H- 120 VAC 1 Duty, 1 Shelf Spare Centrifugal M3V Kubota C8.0 16 138 V - K CIP Flow Meter FIT160101 FE160101 Electromagnetic Endress & Hauser Promag W 400 120 VAC 1 Kubota C8.0 16 120 V - J Act.: Bray S70-006 XV160101 ZS0160101 CIP Flow Control Valve ON/OFF Ball Bray Modulating 120 VAC 1 ZSC160101 HS160101 Vlv.:Asahi Type 21 Kubota C8.0 16 117 V - J CHEMICAL FEED SYSTEMS Alum Injection Pump P-19-01, P-19-02 Peristaltic BlueWhite A1V4-7T 120 VAC 1 duty/1 shelf spare Kubota C10.0 17 96 V - F Caustic Soda Injection Pump P-19-03, P-19-04 Peristaltic BlueWhite A1V4-7T 120 VAC 1 duty/1 shelf spare Kubota C10.0 17 96 V - F Supplemental Carbon Injection Pump P-19-05, P-1906 Peristaltic BlueWhite A2V24-MNGG-3 120 VAC 1 duty/1 shelf spare Kubota C10.0 18 96 V - F Peracetic Acid Pump P-19-07, P-19-08 Peristaltic BlueWhite A4SV24-MTHR 120 VAC 1 duty/1 shelf spare Contractor/Owner C10.0 19 24 IV - 1a WASHWATER LIFT STATION Centrifugal L50P4HMGS-05, Washwater Pump P-10-01, P-10-02 Submersible Pentair Berkley P43B0030A4 3 460 VAC 2 Contractor/Owner C8.0 19 24 IV - 1c True Union PVC Ball Heyward or WW Isolation Valves 2 BV-10201 BV-10101 Valve Equivalent Contractor/Owner C8.0 19 42 IV - 3a True Union PVC Ball Heyward or WW Check Valves 2 CV-10201 CV-10101 Check Valve Equivalent Contractor/Owner C8.0 19 42 IV - 3b Hydropneumatic WW Hydro Pneumatic Tank 1 HP-10-01 Bladder Wessels FXA-500 Contractor/Owner C8.0 19 49 IV - 7 Class 9013 Type Pressure Switch 1 PS-10-01 60-80 psi Square D GMG Series C 120 VAC Contractor/Owner C8.0 19 49 IV - 8 Centrifugal CIP Water Supply Pump P-10-01, P-10-02 Submersible Flygt NP3102 SH3 6.5 460 2 Contractor/Owner C8.0 19 24 IV - 1b True Union PVC Ball Heyward or CIP Pump Isolation Valves 2 BV-10202 BV-10102 Valve Equivalent Contractor/Owner C8.0 19 42 IV - 3b True Union PVC Ball Heyward or CIP Pump Check Valves CV-10202 CV-10102 Check Valve Equivalent 2 Contractor/Owner C8.0 19 42 IV - 3c l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION �N CARO"** S L 2 72 IN 'ter 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com w W NC FIRM#: C-1989 0 / PROJECT: Q W PLURIS HAMPSTEAD VWVFP ry .5 MGD MBR EXPANSION II (n CLIENT: I- PLURIS HAMPSTEAD, LLC z PO BOX 297 W HAMPSTEAD, NC 28443 Project Sheet \ W Date 6/5/24 ClA z Scale J ru 14000 n \ EXISTING PLURIS HAMPSTEAD WWTP SITE / t EX. BLAKE FARM POND, LLC GROUNDWATL:R IMPOUNDMENT / z / , / , / / / v'\. (/ / •\�\ \ _ — �(� i —^ —. `�— — — —L'_ _a ---,.\ - —Y \/ .pab'�6' .�n.�_`:een� _' L.\\lam _� t -- / l/ - ✓5 zez \U 1N3W35V3 3Nn a3M0 l P- �sw� J, '—J-7:1Ir %�� / P \�I /) �l//� II= ;'� /^ , o0009.a0s 1— \ \\ \ \\ \ \\— �/ �/ o � �—' � � o � rill ;I � / _���/>� � 1J /— (� r I' J ` l f 1 O8 6b \ RE \\\ / 1 00 Osb < 08 bb<< 3.29.9L.aos \ l / ) � l ` �\ � \J \\\\\ J -% ✓ —v/ / -, /S� r < / -�\j I��r(� / � � - // s —cam \ \�� _ \ —../ I `� �\\ '-1 \ �\\\\J�i� ^\ / �l /l// ) I �1 1 � �\ r ,/ o/� // rIJ � , � 1 j�\\� \� ;fit/1 ����� J\�\\ s / l ,•i' \ r ��� —� / ( \ \\\�� /r t�r( —.4OQ el / (a /' I r � � \� ill • � / / \ `� .� \ � -- -,� / - \ � r � � � I ;// l / f)��/ �( � / ' I / 1 > _ � J 1 I \ � \ I ( 1 I l� ( T \ . 1 `C , \ •-_ � f i� \ l / / % I f r' ° I � / \ ( � / ~? �,. J \ �� \ � % t\��� \ C ) > —\ �( f/ \��• \111 S_... ) /i j� � �j// ///tl 11 /(( \i\ ��\ 1��� tip/ o / / \ 7/ / / _ =2F,28� 1 \\\�\ ��11/\G� v��D i�/j 1 / I l �� \ \� l 1 1 N \/ 24 f(us r // 5 < ( 1 \ 1�w / 1\1/ti �� jam— ✓�\I \ I \ f—f % L --- r- \\ r h6 _C6 / (�/� / //24 5 ram` l7� .\'cM�N ��.✓� \ \ �_(/ i 1\-� rrh^�N�h / —\ \ �' \ -I_ / ^` ti—\ r // \\ I I \ \/ \ \\/� ✓ i//,ylil (` 1Jl i/-����,- ��: ; 7%%/\ i`�/'\/�%"� �� j ° NPDES OUTFALL 002 NPDES OUTFALL 001 NPDES DISCHARGE 001 5 0' UPLAND OF WETLANDS AND FLOW SPITTER BOX NPDES DISCHARGE 001 5 0' UPLAND OF WETLANDS HOGANS TRAIL 100' PRIVATE ROW 20' WIDE GRAVEL ROAD Z J W U) J J Q w O General Notes 1 IW— SM NC FIRM C-1989 AL FIRM CA-4338— E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN — NOT RELEASED FOR CONSTRUCTION 6/3/24 No. Revision/Issue Date/ 1 MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 PROJECT: PLURIS HAMPSTEAD VWVfP EXPANSION PLANT CLIENT: PLURIS HAMPSTEAD, LLC HOGANS TRAIL HAMPSTEAD, NC 28443 Date 6/3/24 Scale 1 = 200 Sheet C2.00 /V 0 200' 400' �E�89°4�'02"E o wz RB CD i A t� RB Ilk , j EXISTING BLAKE FARM POND GROUNDWATER IMPOUNDMENT EXISTING BLAKE FARM POND � GROUNDWATER IMPOUNDMENT PUMP STATION EXISTING NPDES OUTFACE LINE 0���� — EXISTING WELL (BATHROOM TOILET AND SINK SUPPLY) j EXISTING 0.5 MGD PLURIS HAMPSTEAD IIIII IIIII n —I �� WWTP 2,688 SF, 15.5 H �r 7W3 u �O u LLI �O O EL O '� O A EXISTING GWLS OUTFALL TO GROUNDWATER POND EXISTING 5,000 SF GREENHOUSE EXISTING GWL S - EXISTING EFFLUENT LINE TI HRI BASINS EXISTING HIGH RATE INFILTRATION BASINS EXISTING ANAEROBIC DIGESTER EXISTING DIGESTEWEQ BLOWERS EXISTING FM FROM EQ TO EX. MBR PLANT EXISTING EQ BASIN N /F WILBUR R. CORBETT PIN 3281-15-7192-0000 MB 26 PG 113 ZONE: RA PROPOSED 3" WAS LINE TO ANAEROBIC DIGESTER PROPOSED 6" INFLUENT LINE FROM EQ TO PROP. MBR PLANT PROPOSED 12" GRAVITY LINE TO HRI BASINS EXISTING NPDES OUTFALL LINE Setback Parameter Any habitable residence or place of assembly under separate ownership or not to be maintained as part of the project site Any habitable residence or place of assembly owned by the Permittee to be maintained as part of the project site Any private or public water supply source Surface waters (streams — intermittent and perennial, perennial waterbodies, and wetlands) Groundwater lowering ditches (where the bottom of the ditch intersects the SHWT) Subsurface groundwater lowering drainage systems Surface water diversions (ephemeral streams, waterways, ditches) Any well with exception of monitoring wells Any property line Top of slope of embankments or cuts of two feet or more in vertical height Any water line from a disposal system Any swimming pool Public right of way Nitrification field Any building foundation or basement Impounded public water supplies Public shallow groundwater supply (less than 50 feet deep) Infiltration Treatment / System Storage Units NA NA NA / >230 230 >50 65 NA 50 NA 12301 >230 >70 70 NA NA NA NA NA NA NA NA MONITORING WELL DATA MW 1 (ABANDONED AND REPLACED BY MW4) TOP OF CASING ELE. 45.94 WATER LEVEL 10 FT BELOW TOP OF CASING MW2 TOP OF CASING ELE. 43.59 WATER LEVEL 6 FT BELOW TOP OF CASING MW3 TOP OF CASING ELE. 44.37 WATER LEVEL 9 FT BELOW TOP OF CASING DATA FROM SIGNED AND SEALED SURVEY BY MICHAEL UNDERWOOD AND ASSOCIATES, PA DATED FEB 16 DATUM NA 83 (1986) (PUBLISHED) WATER LEVELS TAKEN FROM WELL LOGS MW4 TOP OF CASING 4' ABOVE GRADE WATER LEVEL 10 FEET BELOW GRADE DATA FROM INSTALLATION RECORD PROPOSED 0.5 MGD PLURIS HAMPSTEAD WWTP 1,932 SF. 15.5 H EXISTING BORROW AREA TO BE DRAINED AND FILLED DURING CONSTRUCTION. A NEW BORROW AREA WILL BE ESTABLISHED NEARER TO THE PROPOSED MECHANICS BUILDING. General Notes IW- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/3/24 No. Revision/Issue Date/ r ............ / EXISTING INFLUENT F ORCEMAIN MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 ga � PROPOSED BORROW AREA TO BE A MINIMUM OF 50' FROM THE gallant1046 lantmc@yahoo.com PROPOSED 0.5 MGD WWTP. z NC FIRM#: C-1989 Q \ / J � % 1 W PROJECT: - EXISTING 20' WIDE GRAVEL DRIVEWAY U) PLURIS HAMPSTEAD vwUrP U) EXPANSION PLANT J - PROPOSED 3,500 SF MECHANICS BUILDING J CLIENT: WITH 5 PARKING SPACES AND GRAVEL PARKING LOT Q < HAMPSTEAD, LLC PLURIS PLURISHOGAN TRAIL W HAMPSTEAD, NC 28443 RELOCATE SECURITY GATE AND ADD FENCING TO ENCLOSE PROPOSED INFRASTRUCTURE Sheet ` C c Date 6/3/24 C201 / W Scale » > 1 = 100 / [� 'I 0 100' 200' 0 40' 80' DENT PUMPS I N / r LATION VALVES, B ,A,, R2 E T 000 r + ND FLOW METER (SEE IN§tT) 6 PC, 113 ZONE: RA O TANK EXCAVATION DEWATERING NOTES: O 1. PLACE DEWATERING PUMP AND FILTER BAG AS SHOWN ON PLAN. \ 2. Ultra—Dewatering Bag 9727-0/S Oil & Sediment Model, 15' x 15' OR EQUIVALENT SHALL BE USED. 3. DEWATERING PUMP CAPACITY SHALL NOT EXCEED 500 GPM. _ 4. WHEN THE DEWATERING BAG IS FULL THE PUMP SHALL BE TURNED OFF AND A NEW BAG INSTALLED. FULL BAGS CAN BE TAKEN TO THE STOCKPILE AREA AND SEDIMENT DISCHARGED AT THAT LOCATION. O INFLUENT FORCE MAIN 6" C-900 O General Notes 1 IW- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION �N CAr?0 v Q S L I` 02 72 '��/nnnnlv`• 6/3/24 I �No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com 3,500 SF NC FIRM#: C-1989 MECHANICS BUILDING FFE = 42.0 PROJECT: PLURIS HAMPSTEAD VWVfP EXPANSION PLANT CLIENT: PLURIS HAMPSTEAD, LLC HOGANS TRAIL HAMPSTEAD, NC 28443 O <oa 9 Sheet I 0 EX. GRAVEL DRIVE Date 6/3/24 O PROPOSED MECHANIC'S UIL C24,2 Scale AND PARKING AREA 1 " = 40) \ / MH RIM4 � RIM 42.0 lNV 3d.50 PLUMB 12" HDPE TO 1 EXISTING 12" HDPE HERE i I O MH #5 RIM 42.0 INV33.50 0+00 U C . O 0-� O � O O o �O n n c yA O C o O nab �' !m O INFLUENT PUMPS ISOLATION VALVES, CHECK VALVES AND FLOW METER (SEE INSET) O O O O O W INFLUENT FORCE MAIN 6" C-900 U 0 40' 80' 4 General Notes \� SM NC FIRM C-1989 AL FIRM CA-4338— E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN — NOT RELEASED FOR CONSTRUCTION 7/23/24 / rNio' No. Revision Issue Date o MICHAEL C. GALLANT, PE, PA 0°° r / PO BOX 4039 SURF CITY, NC 28445 ° / 910-448-1046 gallantmc@yahoo.com • NC FIRM#: C-1989 • / ° ° ° 0 00 UPLEX EQ PUMPS / °°P-03-01,P-03-02 °° r /PROJECT: ° ° / PLURIS HAMPSTEAD WWTP EXPANSION PLANT °° 4" BALL VALVES AND CHECK VALVES / T CLIENT: °°° BV-0301 BV-0302, CV-0301 CV0302 PLURIS HAMPSTEAD, LLC INSTALL ON THE 4" SS VERTICAL LINES HOGANS TRAIL 00 NEAR THE TOP OF THE TANK FOR ACCESS BY / ° ° p THE OPERATOR. TEE 4" DIP LINES INTq HAMPSTEAD, NC 28443 0 ° ° ° ONE 6" DIP LINE AT THE TOP OF THEANK AND EXTEND J i ° ° ° DOWN THE OUTSIDE OF THE TANK. ° ° ° INSTALL FE-030101 FLOW METER ON LOD _ °` / \ ° 00 ° DOWNWARD OUTSIDE 6 DIR LINE/FLANGED CONN3CTIONS. Sheet p LOD - LOD / p ° ° -LOD- ° °° TRANSITION FROM DIP O C-900 Date BELOW GRADE AWAY/ROM TANK FOUNDA ION C2*7/23/24 Scale 1" = 40) EQ INFLUENT PUMP INSET NTS , , O , , O \ MH#2 RIM 42.0 / lNV 38.50 Q 9 � i I •1 55 50 M1 LOD 0 MH #3 RIM 42.0 INV 38 50 SW F/ TANK 1p, SFD PLUMB 12" HDPE TO EXISTING 12" HDPE HERE 12" HDPE GRAVITY LINE - MW4 LOD LOD LOD yQq 1'EpU W N HERE LANT E E� DEWATERING SEDIMENT FILTER BAG 4F FILTFR BAG MH #5 RIM 42.0 INV38.50 WAS _ V �� 0 //PROPOSED GRADE /EXISTING GRADE PLUMB TO WATSING LINE/ FROM INSIDE CONTROL BUILDING PROPOSED 12"/ HDPE GRAVITY 35 LINE TO HRI BASINS WE rI.r OSED WASTING L NE TO >HXISTING DIGESTER '-PLUMB TO EXISTING 4" 3" PVC WASTING LINEAT EXIST ING Dicjf--�7r,ic \PRPOSED INFLUENT FORCE MAIN 6" PVC U 0-� O ILn 0) O O O O o � 0 n O A n $nxm Q'Oo0 nab ,m O ❑::] I I I I o°i I I PR6Pc %C FFE. \4 1V EL. 45: r ', '!�p -i/ O 55 50 M1 35 30 30 0 Co ro �co co 0 �o moo 7 Lq PO -1+00 0+00 1+00 2+00 3+00 4+00 gf CONNECT 4" PVC WASTING LINE (� TO EXISTING DIGESTER INFLUENT LINE fffi E INFLUENT FORCE MAIN AND PROPOSED DUPLEX PUMPS TO BE INSTALLED 0 0'IN EX. EQ BASIN I 4I gI N/F WILBUR R. CORBETT PIN 3281-15-7192-0000 MB 26 PG 113 ZONE: RA TANK EXCAVATION DEWATERING NOTES: 1. PLACE DEWATERING PUMP AND FILTER BAG AS SHOWN ON PLAN. 2. Ultra—Dewatering Bag 9727-0/S Oil & Sediment Model, 15' x 15' OR EQUIVALENT SHALL BE USED. 3. DEWATERING PUMP CAPACITY SHALL NOT EXCEED 500 GPM. 4. WHEN THE DEWATERING BAG IS FULL THE PUMP SHALL BE TURNED OFF AND A NEW BAG INSTALLED. FULL BAGS CAN BE TAKEN TO THE STOCKPILE AREA AND SEDIMENT DISCHARGED AT THAT LOCATION. INFLUENT FORCE MAIN 61, C-900 General Notes IW- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/3/24 No. Revision/Issue Date/ MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 N PROJECT: PLURIS HAMPSTEAD VWVfP EXPANSION PLANT CLIENT: PLURIS HAMPSTEAD, LLC HOGANS TRAIL HAMPSTEAD, NC 28443 Sheet Date C204 6/3/24 Scale 1 = 40 o A /-7 9 55 50 Mi .N O ILn O O C: O Q � O 0 0 n n r py c,^no I $nxw c'0op m Oa anm TT 0O 1 Ll 1 \J V V IN 11_Ll\_L DEWATERING SEDIMENT FILTER BAG FTT .TF.R R A C1 0 NNE(�T 4" WASTING LINE ESITIN TER INFLUENT LINE HERE , 0 40' 80' N/F WILBUR R. CORBETT PIN 3281-15-7192-0000 MB 26 PG 113 ORCE MAIN ZONE: RA SED DUPLEX TANK EXCAVATION DEWATERING NOTES: 1. PLACE DEWATERING PUMP AND FILTER BAG AS SHOWN ON PLAN. BE INSTALLED J�� p 2. Ultra—Dewatering Bag 9727-0/S Oil & Sediment Model, 15' x 15' Q\ASIN OR EQUIVALENT SHALL BE USED. 3. DEWATERING PUMP CAPACITY SHALL NOT EXCEED 500 GPM. _ 4. WHEN THE DEWATERING BAG IS FULL THE PUMP SHALL BE TURNED OFF AND A NEW BAG INSTALLED. FULL BAGS CAN BE TAKEN TO THE STOCKPILE AREA AND SEDIMENT DISCHARGED AT THAT LOCATION. EL - INFLUENT FORCE MAIN 6" C-900 INFLUENT FM===_U = VT G:RAV TY _ V= Wt PLUMB (2) DROP PIPES FROM PUMPS TO A C DMMON TEE, INSTALL A 6" GATE VALVE ON EACH LEG NOTE: THE FROPOSED SUBMERSIBLE PUMPS, RAIL -AND PULUMIS 55 CONNECTIO VS TO THE EXISTING TPVK SHOULD MIRROR THE. EXISTING /EXISTING E( TANK WALL SUBMERSIBLE PUMPS THAT 11.9 FT HIGH FROM TANK FEED THE ORIGINAL PLANK. BOTTOM TO TOP OF WALL CREEN PAD 50 PROPOSED GRAE E FRUFUSEL) WAS IIN(iLINE I PROPOSE>J EQ EXISTING DIGESTER TANK EXISTING GRADE SUBMERS [BLE PUMPS (2) 3" PVC EXISTIN s NP , DISCHARGE LINE FYTvTTN1U1 F1\4 FR01\4 8" PVC COLLECTION SYSTEM 12" PVC NOTE: THE MINIMUM BURY EXISTING SGw LINE DEPTH FOR THIS LINE IS 3 81, PVC \EX EQ TANK FI=ET BELOW FpJISHED FO-JNDATION 35 GRADE. 6 PV C INFLUENT FORCE MAINO 30 L r7 N I-� OO� -1 +00 0+00 1 +00 PROPOSED 12" HDPE GRAVITY LITdE TO HRI BASINS O0 0 �l w 35 55 50PBiOPOSED WASHWATER LIFT STA TION Mi .x 35 7m- PROPOSED CONTROL BUILDING EXTER OR WALL PROPOSED WASTING LINE TO EXISTING VIG&S71 E'_? T_'1I`1Y_ 3 PVC PROPOSES, GRADE PLUMB -O EXISTING 12" DDPE GRAVITY LINE I PRPOSED GRAVITY LINE TO HRI BASINS PRPOSED INFLUENT 12" HIOPE FORCE MAIN 6" PVC NOTE: MAINTAIN A MINIMUM `6" PVC INFLUENT FOF_CE MAIN SEPARATION OF 2' BETWEEN THE EXISTING AND PROPOSED LINES. 30 30 Oo N� 00r �o�j Oo h� �Oq � r � N � 2+00 3+00 4+00 5+00 -1+00 0+00 1+00 Kffeilf� 55 50 w w 35 011 509191 General Notes IW- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/3/24 No. Revision/Issue Date/ MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 Of PROJECT: PLURIS HAMPSTEAD WWTP EXPANSION PLANT CLIENT: PLURIS HAMPSTEAD, LLC HOGANS TRAIL HAMPSTEAD, NC 28443 Sheet Date 6/3/24 C2*5 Scale >, , 1 = 40 35 GTI 002 1 r1S HARGEr-P 0-- 1 t4 21 0 W 77 \ wETLAi\1�LrNE�/ \\ / 1 I \ \ \\\ \ I \\\\\ \\ 11 11 �\\ �\ II \\ \\\\ 1 1 It -/�-D00is \\ / I \ \ 1 I \ \\ \\\ \1 SIJEET C2.8 h 6�—/ ��i ��N \N\I I 0 40' 80, IN —o RELIEVING STRE�M/ 34 \ ` sXol,\ PLUMB NEW DISCHARGE LINE \\ \\\I 1 \\\\\ \ \ 35\ TO EXISTING 8" LIN�, CAPP OFF CIS INGI \\\\\ \\ \ p 1\ \ \ \ \ ,,NOTE. WETLAND LINE — UNUSED DISCHARG \ \ \ FL)\gGED BY OTHERS J \ AA,- '��\ JANUARY 202,4— \ \ o \ \ W _T-tAND_IJI E_ _ _ — — — � _ \ \ i �\ �- \ / 25,-- 5 , \ \\ \\ I \\ \\ \ � pl / \ I 1 1 sX00 ED 002 SEES \ q pp \ / i I 1 I \ \ \ SHEET C2.8 \ SP FLOLITTFR BOX `\ \\ \ SEE HEET/C�1.8 \ �,, V DIRECTION AL BORE UNDER STREAM FED AND WETLAND AREAS 1 � i 25 PLUMB PROPOSED OUTF,mLL LINE EXISTING NPDES DISCHARGE LINE 8" PVC 20 15 -1 +00 h�� L N N N 0+00 �`o 00 �L �o N LO N N 1 +00 NPDES OUTFACE LINE ADDITION / (c3 00 �r- � r7 Nco �o N r7 2+00 FLOW SP LITTER /EXISTING GRADE SEE DEVIL SHEET C2.8 3+00 INV. EL. 27. �(0 INV. E__ 27.5 NN h� o �o n PO 4+00 707 Lw OF 811 CgQQ @ Q.1 poi. Noy �o N N� 5+00 /EXISTING GRADE r �� UPLAND EDGE OF WE 7LANDS _ 1 � c50' F ZOM OUTFALL IN7ERT 6+00 r�oo '-GRI,DE OUTFALL INV. EL. 27.0 DISCHARGE TO 27.0 Oo N00 r0 N N 7+00 am all 35 30 25 KLI 15 9+00 /,0 General Notes 1 IW— SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/3/24 No. Revision/Issue Date/ MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 04 N PROJECT: PLURIS HAMPSTEAD WWTP EXPANSION PLANT CLIENT: PLURIS HAMPSTEAD, LLC HOGANS TRAIL HAMPSTEAD, NC 28443 Sheet N Date C206 6/3/24 Scale 1)) = 40 > 002 1 r1S HARGE---P 0-- 1 t4 21 0 W 77 \ wETLAi\l� LINE / \ \ / 1 I \ \ \\\ \ I \ \ \ \\ \\ 11 11 �\\ �\ II \\ \\\\ 1 1 It -/�-D00is \\ / I \ \ 1 I \ \\ \\\ \1 SIJEET C2.8 h 6�—/ ��i ��N \N\I I 0 40' 80, 00 IN —o RELIEVING STRE�M/ 34 \ sX\ \\ \ 1 / / / / p 1 \ \ I \ \\\ \ \\ ��// / PLUMB NEW DISCHARGE LINE \\ \\\1 \ \\\\\ \ \ 35\ TO EXISTING 8" LIN�, CAPP OFF CIS INGI \\\\\ \\ \ p 1\ \ \ \ \ ,,NOTE. WETLAND LINE — UNUSED DISCHARG \ \ \ FL)\gGED BY OTHERS J \ AA, \\ I \ \ \ JANUARY \ \ \ \ o \ \202,4— W25 -T-tANDIJE— — — \ 0/1 00 3s I 'CF-g,C`900@8.24-Ok ---- \ \ \ ED 002 SEES p0 SHEET C2.8 \ \ \\ / _ \\ FLO SPLITTER BOX \ \ \ w \ \ SEE HEET/C�1.8 \ � V \ QA 002 OUTFACE w 30 25 / 6 LF OF 8" C900 @ 8.24% j 20 15 FLOW SPLITTER SEE DETAIL SF[EET C2.8 /EX_ STING GRADE EL. 27.5 FT. ?7 n : TTDL.111V E- GE OF S / 50' FF_OM OUTFALL IN` ERT `I GRADE OU 7 FALL DISCHARG>H TO 26.5 N N C7 �o -1+00 0+00 1+00 35 30 25 20 15 f►MIN 1 ` \ \ \\\ \ I /,0 General Notes 1 IW— SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION S 72 c1 C G 6/3/24 No. Revision/Issue Date/ MICHAEL C. GALLANT, PE, PA N4 le PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 PROJECT: PLURIS HAMPSTEAD WWTP EXPANSION PLANT CLIENT: PLURIS HAMPSTEAD, LLC HOGANS TRAIL HAMPSTEAD, NC 28443 Date 6/3/24 Scale 1 = 40 >, Sheet C2.7 Of N /V X f UNDISTURBED SOIL (TYP.) .14 X PLAN -BENDS PLAN -TEES 18 MIN. y I�24" MIN., 45° 10" DIA 12"0 & UP m� & LESS +I U 0 m 1MIN.-10" DIA OR LESS C=PLAN 2MINA 2" DIA. OR GREATER D=ELEVATION SECTION X-X PLAN & ELEVATION BENDS & TEES PLUGS PIPE 90' BEND 45° BEND 22-I12° BEND 11-114' BEND TEE PLUG SIZE A B A B A B A B A B C D 4" 18" 12" 10" 13" 7" 10" 7" 10" 12" 14" 13" 6" 6" 18" 12" 10" 13" 7" 10" 7" 10" 12" 14" 19" 9" 8" 24" 18" 13" 18" 10" 12" 10" 12" 16" 18" 25" 11" 10" 28" 22" IS" 22" 12" IS" 12" IS" 20" 22" 31" 14" 12" 32" 28" 19" 28" 14" 18" 14" 18" 22" 28" 37 17 16" 54" 38" 30" 36" 18" 36" 18" 36" 36" 42" 54" 24" ASSUME 2000 PSF SOIL (SAND & GRAVEL WITH CLAY) NOTES: I. BASED ON 200 PSI STATIC PRESSURE PLUS AWWA WATER HAMMER ALLOWANCE. 2. ALL BEARING SURFACES TO BE CARRIED TO UNDISTURBED GROUND. 3. THRUST BLOCKS TO BE USED AT ALL LINES OPERATING UNDER PRESSURE. 4. CONCRETE SHALL NOT CONTACT BOLTS OR MECHANICAL FITTINGS. S. CONCRETE SHALL BE 3000 PSI. 6. TRENCHES SHALL CONFORM WITH STANDARD EMBEDMENT DETAIL 7. ALL BENDS AND INTERSECTIONS SHALL HAVE CONCRETE THRUST BLOCKING. 8. SEE STD. THRUST BLOCK SHEET 2 OF 4 FOR OTHER SOILS. PSD NO. I - THRUST BLOCKING DETAIL NOT TO SCALE COVER 120 LBS. MINIMUM O ° -9 0 a � �j 23 1/2" 21" �0� 0 F F W 0 2 1/8" PLAN 3" SECTION "A" _ 25d 23 3/4" FJ b I � � T 1/2" 21 15/16" 25 15/16" - ELDS MAY ONLY BE USED ID USED N ROADWAY III 33 1/8" APPLICATIONS 518" X 3" LAGSHIELD IN HOLE DRILLED NOTES: INTO CONE OR RING WITH ANCHOR SUNK TO DESIGN DEPTH, AND 518" X 3" I. ALL MANHOLE FRAMES SHALL BE GOOD HOT DIPPED GALVANIZED LAG BOLT AND QUALITY HEAVY DUTY CASTINGS WASHER. 2. FRAME SHALL BE A MINIMUM WEIGHT OF 182 LBS. 3 COVER SHALL WEIGH A MIN OF 120 LBS 4. MANHOLES WITHIN PAVED SURFACES SHALL BE CONSTRUCTED IN ACCORDANCE WITH DETAIL. 5. CONSEAL SHALL BE USED BETWEEN RING AND CONE PSD NO. 18 - STANDARD MANHOLE RING AND COVER NOT TO SCALE SIPHON BREAK 11 NOTE: HOSE BIB SHALL ACCOMMODATE STANDARD 3/4' GARDEN HOSE. m TOP OF SLAB 1 CFH57 > WASHED STONE m z N 12" 1 TYPE K, 1" DIAMETER COPPER WITH THREADED TO COMPRESSION FITTING AT HYDRANT STANDARD YARD HYDRANT (NON -FREEZE) REACTION BEARING AREAS FOR HORIZONTAL WATER/SEWER PIPE BENDS BASED ON TEST PRESSURE OF 200 P.S.I. ALL ARS GIVEN IN SQUARE FEET z' O 0/. 6" II 114 ° 1,108 1 1 2 1 22112 2,207 2 2 1 3 1 45 ° 4,328 2 3 3 1 1 2 5 1 90 ° 7,996 2 4 5 1 1 2 8 1 PLUG 5,655 2 3 4 1 1 2 6 1 BI 1114 1,970 1 1 2 1 1 1 2 1 22112 3,922 1 2 3 1 1 1 4 1 45 ° 7,694 2 4 5 1 1 2 8 1 90 ° 14,215 4 8 9 2 2 4 15 2 PLUG 10,053 3 5 6 2 2 3 10 1 12" II 114 4,433 2 3 3 1 1 2 5 1 22112 8,826 3 5 6 2 2 3 9 1 45 ° 17,312 5 9 II 3 3 5 18 2 90 ° 31,983 8 16 19 4 4 8 32 4 PLUG 22,619 6 12 14 3 3 6 23 3 16" II 114 7,881 2 4 5 1 1 2 8 1 22112 ° 15,691 4 8 10 2 2 4 16 2 45 ° 30,779 8 16 19 4 4 8 31 4 90 ° 56,861 15 29 35 8 8 15 57 6 PLUG 40,213 10 21 25 5 5 10 41 5 REACTION BEARING AREAS ARE IN SQUARE FEET MEASURED IN A VERTICAL PLANE IN THE TRENCH SIDE AT AN ANGLE OF 900 TO THE THRUST VECTOR. USE 6" - 900 BEND VALUE FOR HYDRANTS FOR ADDITIONAL SAFETY FACTOR. PSD NO.2 - THRUST BLOCKING DESIGN QUANTITY TABLE NOT TO SCALE STD. MANHOLE COVER, b MANHOLE STEPS F AS SPECIFIED O � RAM-NEKJOINT MAT'L -�\�-- OR APPROVED EQUAL Z (TYPICAL) PRECAST MANHOLE SECTION, g AS.T.M. C 478 5" MIN. y; ° 4' MINIMUM 6" > MIN. 0'-6" MONOLITHIC CONCRETE BASE. IN. s 3000 PSI CONCRETE ` 6" MIN. iXXXJCXXXXrSrr,o: or 1 12" MIN. �� "`CRUSHED STON�v NOTE: ADDITIONAL EXTENDED BASE MAY BE REQUIRED WHERE MANHOLES DEPENDING ON ANTIFLOTATION CALCULATIONS PSD NO. 21 - SANITARY SEWER PRECAST MANHOLE DETAIL NOT TO SCALE i A 270 PRECAST CONCRETE COLLAR FINISH GRADE - VALVE BOX WITH LID GATE VALVE (1 MECH. JOINT PSD NO. 15 - GATE VALVE DETAIL NOT TO SCALE D ENERGY DISSAPATOR DETAIL FOR SWALE OUTLETS NOT TO SCALE e B PLAN VIEW NOTES: ALL SIDE SLOPES TO BE 2: 1 MINIMUM, 6" RIP RAP, 18" THICK WITH 3" OF ABC STONE UNDERLAYMENT DETAIL APLIES FOR WING W4L INLETS AND OUTLETS AND ENERGY DISSIPATOR AT WET POND OUTLET APRON WIDTH AND LENGTH DESIGNED USING FIG 806.B.1-3 IN MANUAL (PAGE 8.06.4. WHERE DISSIPA TOR IS IN OR PART OF A CHANNEL THE WIDTH IS TO EXTEND TO THE TOP OF THE CHANNEL. A ��i��C�Pwst Fa$fi45* SECTION A -A ID Q10 Do La W ED 001 1.0 3' 10' 8' ED 002 1.0 3' 10' 8 rnMPACTED BACKFILL TO ODIFIED PROCTOR DER PAVEMENT ORE WALLS TO ANGLE OF POSE OF SOIL OR AS 'PROVED BY THE ENGINEER ACTED PIPE EMBEDMENT o MODIFIED PROCTOR 1 OR II MATERIAL :INPIx71��1gg9'ull�ll'uLO'ul PIPEWIDTH+24" TRENCH BOTTOM NOTES: I. MINIMUM BURY DEPTH FOR ALL FORCE MAINS AND GRAVITY LINES IS 36" UNLESS SPECIFICALLY ALLOWED BY THE ENGINEER ALL LINES SHALLOWER THAN 36" MUST GIVE CONSIDERATION TO USING HIGHER PRESSURE AND THICKNESS CLASSES OF DIP. 2. ALL LINES TO BE BEDDED IN 6" OF 457 STONE MINIMUM. FOR LINES INSTALLED BELOW THE WATER TABLE 457 STONE SHOULD EXTEND TO THE SPRING LINE OF THE PIPE AT A MINIMUM. 3. THE USE OF #57 STONE BEDDING AND BACKFILL SHOULD BE COMMENSURATE WITH THE CONDITIONS IN THE TRENCH. THE CONTRACTOR IS RESPONSIBLE FOR PROPER BEDDING AND BACKFILLING TO INSURE PIPE STABILITY AND UNIFORM GRADE. PSD NO. 9 - PIPE TRENCH AND BEDDING DETAIL NOT TO SCALE PLAN VIEW BAFFLE WALL 17 / �.. 8" OUTLET : 8" INLET ALUMINUM TOP GRATE I�8 OUTLET 8.25" 6.88" 0.69" f0.69" ❑❑❑ r SEWER A ❑❑❑ 1 7.25" } 11871 PLAN BOX 7„ 6.69"DIA r0, 125' 110 5' 0.32" 0.5" 6.5"DIA 0.5" PSECTION "I LA MINIMUM WEIGHTS: EXTENSION TOP 10 LBS, BOX 40 LBS. NOTE: EXTENSION 40 LBS. VALVE BOX LID NOT FOR USE IN ROADWAY LOCATIONS. HEAVY DUTY LID REQUIRED. SEE SD 14-08. PSD NO. 12 - CAST IRON VALVE BOX DETAIL NOT TO SCALE SPLITTER BOX NOTES: 1. 6' X 6' PRECAST BOX WITH MINIMUM DIMENSIONS A SHOWN. 2. RIM EL. 32.0, BOTTOM EL. 27.0. 3. INSTALL ON 6" OF COMPACT STONE 4. (2) 4" SS WIER PLATES TO HAVE A MINIMUM OPEN WIDTH OF 18" AND SET EQUALLY AT EL. 30.00. WIER PLATES MUST BE LEVEL AND AT THE SAME ELEVATION TO ASSURE AN EQUAL FLOW SPLIT. IT IS SUGGESTED THAT ONE LONG PLATE BE USED AND EMBEDDED INTO THE BAFFLE WALL. 5. 8" BOOTS PRECAST INTO BOX FOR 8" PVC PIPE. 6. ALUMINUM GRATE SET INTO THE TOP OF THE BOX, BOLTED IN PLACE FOR MAINTENANCE ACCESS. WIER INV. EL. 3 0. 00 .. �. .I. RIM EL. 32.0 �. BOTTOM EL. 27.0 4" SS WIER PLATE TYP. 8" INLET EX. GRADE EL. 30.0 :�,�„ EX. GRADE EL. 30.0 INV. 27.5 :' � ._ ; .. •t; ;ram 811 OUTLET INV. 27.5 III SECTION FLOW SPLITTER BOX DETAIL NITS 4 General Notes �- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 END SECTION No FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/5/24 Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 � >r PROJECT: \ PLURIS HAMPSTEAD VWVfP .5 MGD MBR EXPANSION J CLIENT: PLURIS HAMPSTEAD, LLC W PO BOX 297 HAMPSTEAD, NC 28443 V Project Sheet \ ^Z I..L Date 6/5/24 C2m8 III > Scale 1/8)) = 1 10�0/ s 10' SIDE WALK-\ N N A 11-211 � s s s C) 0 M PAX-0 I y PRE -ANOXIC BASIN 0 I in r ': • ,SEE DETAIL 2.1 TYP. SHEET C3.2 10' SIDE WALK 151-011 11-211 � s 2— s YH A 0 r TANK FOOTING 6' FROM WALL TYP. 201-1011 3- 10' SIDE WALK-\ 11-211 11-211 ---a— s i � A YH SEE DETAIL 2.4 TYP. SHEET C3.2 I o PA-02 C ; MB-02 PRE -AERATION BASIN � I MBR BASIN N �i fN r-----------------'------------------------ �---------------------------- r 1 32" WIDE WALKWAY 32" WIDE WALKWAY SEE DETAIL 2.2 TYP. SHEET C3.2 PA-01 PRE -AERATION BASIN r 421-011 ON I_ O 951-1011 3— s COM MONWALL TANK PLAN VIEW 1/411 = 11 101-011 0 21-811 (i M 3— s A N �i fN r -----L - - - - - - - - - - - - - - - - - - - ------------- 32" WIDE WALKWAY MB-01 MBR BASIN 32" WIDE WALKWAY 231-011 r C<- a fi l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION (N CA/�C S L 2 72 VJ z''� ;/IICI�I 0 6/5/24 U) z W o. Revision/Issue Date, r) z ` \ z MICHAEL C. GALLANT, PE, PA JPO BOX 4039 SURF CITY, NC 28445 910-448-1046 J gallantmc@yahoo.com Q ry NC FIRM#: C-1989 U PROJECT: ry PLURIS HAMPSTEAD VWVfP 1 .5 MGD MBR EXPANSION U) �e CLIENT: z PLURIS HAMPSTEAD, LLC Q PO BOX 297 HAMPSTEAD, NC 28443 i�Project Sheet z ODate 6/5/24 CIO Scale O 1 /8„ = 1 > U � � s FINE SCREEN -- SIDE WALK 1'-2" EL. = 50.25 10'-0" A O pn I 0 p I N pp TOP OF WALL EL. 51.0 15'-0" E D \/ _ D D c D Ln T--I SEE DETAIL 2.6 TYP. SHEET C3.2 SEE DETAIL 2.8 TYP. SHEET C3.2 TANK BOTTOM EL. 31.0 42'-0" 95'-10" 4' RISE IN TRUSS a TOP OF WALL EL. 51.0 1'_2" 1'-2" 1'-2" 95'-1011 10'-011 L 23'-011 21_811 p - v D 21-011 'p s C D f p C > O O 00 G C . rl 1U VI I.VI'IrP1\.I #57 STONE PAX-01 1 PA-02 AXP-01 MB-02 PRE -ANOXIC BASIN PRE -AERATION BASIN POST ANOXIC BASIN MBR BASIN SIDE WALK EL. = 47.5-� (45.0 AT CONTROL BUILDING) 6'-0" I � SEC I ION 'A' 4' = 1' TOP OF WALL EL. 51.0 1'-2" 121_3" SEE DETAIL 2.5 TYP. >HEET C3.2 11_2n a 10-011 10�_011 1 C .a 131_011 131_011 n .. o.a 0 1,_2„ 0 s a . 0 e n N a n A TANK BOTTOM EL. 31.0 a ` 61_On � s C ba 1U VI #57 STONE SECTION ' C' 4" = 1' 0 D 6'-0" 61-011 NOTE: _ TYPICAL WALL REINFORCEMENT VERTICAL: #8 BAR 0 4" OC BOTH SIDES HORIZONTAL: #8 BAR @ 6" OC BOTH SIDES I MIN. COVER OF2" 4 CONTI 0 General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ,p�a ICARn�i %�� �""t Z C nGP` Q 6/5/24 U) Z W 2 No. Revision/Issue Date, U) Z O MICHAEL C. GALLANT, PE, PA U w PO BOX 4039 U) SURF CITY, NC 28445 910-448-1046 J gallantmc@yahoo.com r/ NC FIRM#: C-1989 U` Z) PROJECT: ry PLURIS HAMPSTEAD VWVfP 1 .5 MGD MBR EXPANSION U) V CLIENT: z PLURIS HAMPSTEAD, LLC Q PO BOX 297 HAMPSTEAD, NC 28443 3�J#Project Sheet \ Z ODate 6/5/24 C3m 1 Scale O U � 10�0 ii #8 BAR @ 6" OC ��. #8BAR @6"OC #8BAR @4"OC DETAIL 2.1 WALL CORNER PLAN DETAIL NTS 2'8' STIRRUP #6 BAR LO 6" OC CROSS BARS #6 BAR WELDED 1 o ' ' WALL REINFORCEMENT . VERTICAL: #8 BAR 0 4" OC BOTH SIDES HORIZONTAL: #8 BAR Cp 6" OC BOTH SIDES MIN. COVER OF2" #6 BAR L& 6" OC Ld = 50" FOR ALL SPLICES DETAIL 2.6 WALL W/ OFFSET WALK SECTION DETAIL NTS #8 BAR @ 4" OC -OP DETAIL 2.2 WALL TEE PLAN DETAIL NTS DETAIL 2.3 WATERSTOP AND COLD JOINT FOR TANK WALLS AND SLAB NTS WALL REINFORCEMENT • VERTICAL: #8 BAR 4" OC BOTH SIDES HORIZONTAL: #8 BAR 6" OC BOTH SIDES MIN. COVER OF2" Ld = 50" FOR ALL SPLICES TANK SLAB REINFORCEMENT #5 BAR LO 9" OC BOTH DIRECTIONS TOP AND BOTTOM MAT 3"X 3" KEY W/ 6" WATER STOP 3" COVER OVER BOTTOM MAT TYP. . . CENTERED 2"COVER OVER TOP MAT TYP. REINFORCEMENT IS CONTINUOS THROUGH • / ENTIRE SLAB . . . . . . . . . . . . . . . . . . . #8 BAR DOWELS 0 6" OC TYP. — —' #8 BAR DOWELS 6" OC TYP. / MINIMUM 18" OF #57 STONE CONTINUOUS UNDER SLAB DETAIL 2.7 INTERIOR WALL/SLAB JOINT SECTION DETAIL NTS 1 - FLOW CAP ry � NOMINAL WIDTH NOMINAL WIDTH �J TOP OF WALL 15"D X X W p, GRATING LEDGE TYP o 6 DETAIL 2.4 SLIDE GATE OPENING DETAIL NTS SLIDE GATE OPENING DETAIL NOTES: 1. NOMINAL WIDTH FOR ALL GATES IS 3'. THIS IS THE ACTUAL OPEN WIDTH IN THE GATE AFTER INSTALLATION. CONTRACTOR SHOULD VERIFY GATE FRAME DIMENSIONS TO ALLOW FOR THE MINIMUM NOMINAL WIDTH OF 3'. 2. THE NOMINAL DEPTH IS THE INVERT OF THE GATE WHEN INSTALLED. 3. GATE INVERT ELE. = 48.2 FOR ALL GATES. 3'2' MAIN STEEL #6 BAR LO 6" OC CROSS BARS #6 BAR WELDED \ �1 FRAMING BARS ' #5 BAR TYP. o ' WALL REINFORCEMENT ' VERTICAL: #8 BAR L& 4" OC BOTH SIDES HORIZONTAL: #8 BAR LD 6" OC BOTH SIDES MIN. COVER OF2" MAIN STEEL #6 BAR @ 6" OC 1 CROSSBARS #6 BAR WELDED CLOSED STIRRUPS #6 BAR @ 4 " OC • Ld = 50" FOR ALL SPLICES DETAIL 2.5 WALL W/ WALK SECTION DETAIL NTS WALL REINFORCEMENT • VERTICAL: #8 BAR 4" OC BOTH SIDES HORIZONTAL: #8 BAR 6" OC BOTH SIDES MIN. COVER OF2" Ld = 50" FOR ALL SPLICES 3 " X 3" KEY W/6" WATER STOP TANK SLAB REINFORCEMENT . CENTERED # 5 BAR @a 9" OC BOTH DIRECTIONS #8 BAR DOWELS L3 6" OC TYP. . . / #8 BAR DOWELS L0 6" OC TV . TOP AND BOTTOM MAT 3" COVER OVER BOTTOM MAT TYP. 2" COVER OVER TOP MAT TYP. REINFORCEMENT IS CONTINUOS THROUGH . . ENTIRE SLAB MINIMUM 18" OF #57 STONE DETAIL 2.8 CONTINUOUS UNDER SLAB EXTERIOR WALL SLAB JOINT SECTION DETAIL NTS THE MINIMUM LAP DISTANCE, Ld FOR #8 BAR IS 50". NO LAP SHALL START OR STOP TYPICAL WALL REINFORCEMENT Cn WITHIN 2 FEET OF ANY COLD JOINT. LAPS SHALL NOT EXTEND THROUGH A VERTICAL: #8BARLO4"OCB0THSIDES J COLD JOINT. HORIZONTAL: #8 BAR La 6" OC BOTH SIDES Q MIN. COVER OF 2" BAR SIZE AND MINIMUM BEND DIAMETERS LU SIZE NOM. DIA. (IN) MIN BEND DIA ~ Z LU #4 .500 311 #5 .625 3.75" LU #6 .750 4.511 CU #8 1.00 611 #9 1.128 10" 0 LL Z ALL VALUES ABOVE WERE DERIVED FROM ACI-318-95 CHAPTERS 7 AND 12 LLJ SECTIONS 318-177, 318-63 0� 4 General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ,p"',a fCARn"", 251572 cL C G 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 PROJECT: PLURIS HAMPSTEAD VWVfP .5 MGD MBR EXPANSION CLIENT: PLURIS HAMPSTEAD, LLC PO BOX 297 HAMPSTEAD, NC 28443 Project Date 6/5/24 Scale 1 8 = 1 Sheet C12 J CONCRETE PLACEMENT NOTES: SIDEWALKS 1. ALL SIDEWALKS ARE TO BE 4000 PSI 28 DAY CONCRETE, 6" THICK WITH 6" OF COMPACT ABC STONE UNDERLA YMENT. 2. SIDEWALKS ARE TO BE REINFORCED WITH 6 X 6 WWF. 3. INSTALL EXPANSIONJOINTS /NALL AREAS WHERE ANYSIDEWALKABUTS TANK WALLS OR BUILDING FOUNDATIONS. 4. INSTALL EXPANSION JOINTS EVERY 10 LF OF SIDEWALK. 1 " CLOSED CELL POL Y FOAM TYP. EQUIPMENT/CONTROL ROOM FLOOR SLAB 1. FLOOR SLAB SHALL BE 6" 3500 PS/ 28 DAY CONCRETE WITH TURNED DOWN FOOTING AS SHOWN ON SHEET C3.6. THE PER/METER FOOTING SHALL HAVE (2) #5 BARS CONTINUOUS THROUGH THE FOOTING. 2. FLOOR SLABS ARE TO BE SMOOTH FIN/SHED AND SAW CUT AT EVEN INTERVALS PER PLAN IN BOTH DIRECTIONS. FINISH FLOOR SLABS WITH CLEAR SEALER. 3. SLAB SHALL BE PLACED ON A MIN/MUM OF 12" OF #57 STONE. 4. ALL EQUIPMENT PLACED IN THIS AREA SHALL BE ELEVATED ON A CONCRETE PAD A MINIMUM OF 3" ABOVE THE FINISHED FLOOR GRADE. SEE SHEET C3.6 FOR DETAILS INCLUDING LUG FOR ELEVATING ELECTRICAL PANELSIN THE CONTROL ROOM. COMMON WALL TANK FOUNDATION 1. THE CONTRACTOR SHALL OBTA/NA COPY OF GEOTECHN/CAL SO/LSANALYS/S FROM S&MEAND REVIEWAND FOLLOWALL RECOMMENDATIONS /N THEANALYS/S FOR PREPARATIONAND PLACEMENT OFALL STONEAND CONCRETE. THE CONTRACTOR SHALL VERIFYALL COMPACT/ON VALUES OFSUBGRADES PR/OR TO PLA CING ANY STONE, REINFORCEMENT OR CONCRETE BY FIELD TESTING BYA CERTIFIED CONSUL TANTAND FURNISH ALL TESTING DATA AND RESULTS TO THE ENGINEER. 2. THE SUBGRADE OF THE TANK FOUNDATION SLAB SHALL HAVE A MIN/MUM BEARING PRESSURE OF 3000 PSF. ALL TESTING DATA FOR SUBGRADE BEARING CAPACITY IS TO BE SUBMITTED TO THE ENGINEER FOR APPROVAL BEFORE ANY CONCRETE OR REINFORCEMENT IS PLACED. 3. THE SLAB SHALL BE PLACED ON A BASE OF #57 S TONE. THE STONE BASE SHALL BE COMPACTED PER THE GEO TECHN/CAL SOILS REPORT FOR THE PROJECT PREPA RED BYS& ME. ALL TES T DA TA FOR COMPACT/ON /S TO BE SUBM/ TTED TO ENGINEER FOR APPROVAL BEFORE CONCRETE OR REINFORCEMENT IS PLACED. 4. THE CONTRACTOR /S RESPONSIBLE FOR DEWATER/NG THE EXCA VAT/ON PR/OR TO AND DURING THE PLACEMENT OF THE STONE BASE, REINFORCEMENT AND CONCRETE. 5. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL CLAY OR OTHERWISE UNSUITABLE SOIL BELOW TANK FOUNDATION BEFOREADD/NG STONE BACKFILL. COMMON WALL TANK REINFORCEMENT 1. ALL REINFORCING STEEL SHALL BE 60 KS/ STEEL. 2. ALL STEEL REINFORCEMENT IS TO BE PLACED A MIN/MUM OF 3" FROM THE FACE OFA POUR WHEN POURING AGAINST EARTH OR STONE BASE SURFACE. PLACE STEEL REINFORCEMENT A MINIMUM OF 2" FROM ALL FORMS OR 2" BELOW ALL FINISHED SURFACES. 3. ALL JOINTS, BENDS AND PLACEMENT OF REINFORCEMENT SHALL FOLLOW THE STANDARDS IN THE MOST RECENT VERSION OFACI-318. 4. SEE SHEET C3.2 FOR MIN/MUM BEND DIAMETERS AND LAP DISTANCE. 5. ALL TYPICAL INDUSTRYSTANDARDS SHALL BE FOL L O WED FOR THE PLACING AND TOL ERA NCE OF PLACEMENT OF A L L REINFORCEMENT. THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHEN RE/NFORCEMEN T HA S BEEN PLACED SO THAT THE ENGINEER CAN VERIFY THE BAR SIZE AND SPACING OFALL REINFORCEMENT. COMMONWALL TANK CONCRETE PLACEMENT 1. ALL WORKSHALL FOLLOW STANDARD INDUSTRY PRACTICES FOR SANITARY TANKS AS OUTLINED IN THE PORTLAND CEMENT ASSOCIATION PUBLICATION "RECTANGULAR CONCRETE TANKS", ACI 31S AND ALL OTHER APPLICABLE INDUSTRYSTANDARDS. 2. TANK WALLS AND FOOTINGS ARE TO BE 4000 PSI 28 DAY CONCRETE WITH LOW MOISTURE CONTENT. PLACEMENT OFALL REINFORCEMENT IS TO BE INSPECTED BEFORE CONCRETE IS PLACED. NORMAL INDUSTRYSTANDARDS FOR WEATHER CONTINGENCIES SUCHAS EXCESSIVE HEAT OR COLD ARE TO BE FOLLOWED. 3. THE CONTRACTOR /S REQUIRED TO TEST THE CONCRETE MIX AND FURNISH ALL DATA SHOWING THAT THE CONCRETE PLACED FOR THE TANK FOUNDAT/ON AND WALLS MEETS OR EXCEEDS A COMPRESSIVE STRENGTH OF 4000 PSI (28 DAY). 4. THE CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS FOR ALL SLABS, WALLS AND SIDEWALKS. THESE SUBMITTALS SHALL DESIGNATE THE TYPE OFAGGREGATE, CEMENT AND PLACEMENT METHODS FOR ALL POURS. THE SUBMITTAL SHALL INCLUDE THE DESIGN TARGET STRENGTH, AIR CONTENT, SLUMP AND ADDITIVES /N EACH DESIGN. THE TARGETSLUMP FOR ALL PADS AND SIDEWALKS SHALL BE 4 INCHES. THE TARGETSLUMP FOR ALL WALL POURS SHALL BE DESIGNATED /N THE MIX DESIGN. WALL MIX DESIGNS SHALL USE PEA GRAVEL AGGREGATE. 5. THE TOLERANCE FOR SLUMP SHALL BE +/-1 INCH. THE TOLERANCE FOR AIR SHALL BE +/-1.5%. 6. THE CONTRACTOR SHALL SUBMIT A PLAN AND SCHEDULE FOR CONCRETE POURS THAT /S REASONABLE AND MEETS INDUSTRYSTANDARDS. THE POUR SCHEDULE SHALL ALLOW FOR MULTIPLE NON CONTIGUOUS SECTIONS OF THE SLABS AND WALLS TO BE POURED AT THE SAME TIME. 7. THE CONTRACTOR IS RESPONSIBLE FOR INSURING THAT CONCRETE ARRIVING AT THE SITE HAS HAD ENOUGH TIME /N TRANSIT TO ASSURE PROPER MIXING. THE CONTRACTOR SHALL EVALUATEALL CONCRETE ARRIVING ON SITE FOR POOR MIXING OR THE PRESENCE OF CLAY IN THE MIX. ANY CONCRETEARRIVING ON SITE THAT DOES NOT MEET THE MIX DESIGN STANDARDS OR APPEARS TO HAVE A LARGE CLAY CONTENT OR NON HOMOGENEOUS CHARACTER SHALL BE REJECTED AND NOT USED. 8. THE CONTRACTOR SHALL PLACE WATERSTOPS AT ALL JOINTS BETWEEN POURS AND AS SHOWN ON THE PLANS. ALL WATERSTOPS SHALL BE WILLIAMS 3096-3 6" DUMBELL OR EQUIVALENT. 9. ALL EMBEDDED PIPES SHALL BE INSTALLED USING INDUSTRY STANDARD METHODS. THE CONTRACTOR SHALL SUBMIT THE MATERIALS AND METHODOLOGY FOR ALL PIPE PENETRATIONS. 10. THE CONTRACTOR SHALL FOLLOW INDUSTRY STANDARDS FOR ALL FORMWORKAND SHALL SUBMIT MATERIALS AND METHODOLOGY FOR SECURING AND SUPPORTING ALL FORMWORK. THIS INCLUDES ALL TIES AND METHODS OF SEALING ALL HOLES AFTER FORMS ARE REMOVED. 11. THE TOLERANCES FOR ALL SLABS AND WALLS WHEN PLACED SHALL ADHERE TO THE FOLLOWING CRITERIA: A) VARIATION FROM THE PLUMB NOT TO EXCEED %"IN TEN FEET OR 1 "MAX/MUM FOR THE OVERALL HEIGHT OF THE WALL. B) VAR/AT/ON FROM THE LEVEL NOT TO EXCEED "IN TEN FEET. C) LINEAR BUILDING ELEMENTS NOT TO EXCEED MORE THAN 1" OVER THE ENT/RE LENGTH. D) FLOORS SHALL NOT EXCEED MORE THAN %"UNDER A TEN FOOT STRAIGHT EDGE. 12. THE CONTRACTOR SHALL POUR ALL WALLS /N ONE VERTICAL POUR OF 20' IN DEPTH. THE CONTRACTOR /S RESPONSIBLE FOR ASSURING THE MIXDESIGN. FORM WORKAND PLACEMENT METHODOLOGY CAN ACCOMPLISH A WALL POUR OF THIS DEPTH. THE CONTRACTOR SHALL TAKE CARE TO USE INDUSTRYSTANDARDS AND EQUIPMENT TO ASSURE THAT NO GAPS OR HONEYCOMBING ARE PRESENTIN THE FINISHED WALLS AND SLABS. 13. ALL CONCRETE PLACEMENT SHALL CONFORM TO A CLASS B FINISH AS OUTLINED IN ACI 301. 14. IN THE CASE OF POOR QUALITY WORK, LEAKS, HONEYCOMBING, OR SURFACES THAT ARE NOT PLUMB, LEVEL AND STRAIGHT WITHIN THE STATED TOLERANCES, MEETING THE TYPICAL INDUSTRYSTANDARDS FOR SUCH WORKAND AS SHOWN ON THE PLANS THE CONTRACTOR SHALL REMEDYALL DEFECTS TO THE COMPLETE SATISFACTION OF THE OWNER AND ENGINEER. THIS INCLUDES ALL REPAIRS OR /F REQUIRED DEMOLITION OFANYAFFECTED AREAS. TESTING 1. ALL CONCRETE SHALL BE TESTED AS OUTLINED /N THE NOTES ABOVE FOR COMPLIANCE WITH SUBMITTED MIX DESIGNS PR/OR TO PLACEMENT. THIS INCLUDES BUT IS NOT LIMITED TO SLUMP AND AIR CONTENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ON SITE TESTING BYA CERTIFIED FIRM OR INDIVIDUAL AND SHALL SUBMITALL TESTING DATA AND LOGS TO THE ENGINEER. 2. ALL CONCRETE SHALL BE TESTED FOR COMPLIANCE WITH THE REQUIRED COMPRESS/ VE STRENGTH REQUIRED /N THESE NOTES AND ON THE PLANS. ALL TEST RESULTS SHALL BE FURNISHED TO THE ENGINEER. 3. EACH POUR SHALL HAVEALL REQUIRED PARAMETERS TESTED AT LEAST TWICE, ONCEAT THE BEGINNING AND ONCEAT THE END OF THE POUR. FOR LARGE POURS OR MULTIPLE POURS /N ATA SINGLE TIME THE TESTING SHALL BE EVERY50 YARDS MINIMUM. 4. PRIOR TO BACKFILLING THE TANK SHALL BE TESTED FOR LEAKS. ALL CELLS WILL BE FILLED WITH WATER INDIVIDUALLY TO ASSURE INTEGRITY FROM CELL TO CELL. LEAK TESTS WILL BE PERFORMED OVER A 24 HOUR PERIOD AND TAKE INTO ACCOUNT EVAPORATION AND PRECIPITATION. IN NO CASE SHALL ANY PORT/ON OF THE STRUCTURE LOSE MORE THAN .055 OF THE TANK VOLUME IN A 24 HOUR PERIOD. 5. IN THE CASE OF LEAKING THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING MATERIALS AND METHODS FOR REPAIR OR REPLACEMENT TO THE FULL AND COMPLETE SATISFACTION OF THE OWNER AND ENGINEER. 6. ALL LEAKS, WATER LOSS, DEFECTS OR OTHER PROBLEMS WILL BE REPORTED TO THE ENGINEER. TANKS WILL BE EMPTIED AND INSPECTED AFTER TESTING FOR SIGNS OF INFILTRATION OR EXFILTRATION. BACKFILLING 1. THE TANK SHALL BE BACKF/LLED /N 6" LIFTS. LIFTS SHALL BE COMPACTED USING LIGHT EQUIPMENT AND TANKS SHALL BE INTERNALLY BRACED DURING ALL BACKFILLING. THE CONTRACTOR SHALL TAKE CARE TO AVOID HEA VY LOAD/NG OF SOILS INCLOSE PROXIMITY OF THE TANK. SEE RECOMMENDATIONS /N SOILS ANALYSIS BYS&ME FOR BACKFILLING AND COMPACTION AROUND TANK WALLS. l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/5/24 No. Revision/Issue Date, MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 W 1-- ` \ PROJECT: OPLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION Z W CLIENT: 75 PLURIS HAMPSTEAD, LLC W PO BOX 297 () NC 28443 Q \HAMPSTEAD, nJ '+ _ AeProject Sheet \ W Date W 6/5/24 C33 Z Scale 1 /8» = 1 > 0 s L man CONTROL BUILDING ROOF PLAN 1/4" = 1' a A r A r 12" PVC-WWLS-001� '1 1 TURNDOWN SLAB CONTROL BUILDING SLAB PLAN 1/4" = 1' l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ���� � F E • SjG C/ ��i� S L 2 72 6/5/24 No. Revision/Issue II Date J MICHAEL C. GALLANT, PE, PA 121- PO BOX 4039 m SURF CITY, NC 28445 Q 910-448-1046 J gallantmc@yahoo.com U) NC FIRM#: C-1989 0 *% z Q IL `PROJECT: 0 PLURIS HAMPSTEAD VWVfP 0 .5 MGD MBR EXPANSION ry Ur CLIENT: z PLURIS HAMPSTEAD, LLC Q PO BOX 297 J HAMPSTEAD, NC 28443 D \ Project Sheet J 0 Date 6/5/24 C14 z Scale 0 1 4 = 1 U J 4' RISE IN TRUSS I 2 A 12" PVC-WWLS-001 40'-0" /(2) 3068 EXT DOORS \"-3 - 2 X 6 JACKS MIN. 3 - 2 X 6 JACKS MIN. 2 - 1.75 X 12 LVL HEADER MANUFACTURED ROOF TRUSS BY OTHERS W 0 m ao HVAC -001 MINI -SPLIT CONDITIONING UNIT EXF -001 EXHAUST FAN 3 - 1.75 X 12 LVL HEADER 4-2X6JACKSMIN . 4-2X6JACKS MII 12' WIDE ROLL UP DOOR I I E I 23'-6" 23'-0" 16'-6" CONTROL BUILDING FLOOR/FRAMING PLAN 1/4" = 1' MONOSLOPE ROOF TRUSS A 2X6SPFSTUDS, 16"OC 2" OSB SHEATHING, FULLY BLOCKED ON BOTH INSIDE AND OUTSIDE OF THE WALLS NAILING PATTERN 3" ON THE EDGE 6" IN THE FIELD CEMENT LAP SIDING CLOSED CELL SPRAY FOAM INSULATION WIDE X 8" HIGH g� ELECTRICAL PEDESTAL TYP. 2'-0„ CONTROL BUILDING SLAB TO HAVE A MINIMUM OF 12" OF COMPACT STONE CONTROL BUILDING SECTION 1/4" = 1' UNDERLAYMENT l General Notes �— SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 z No 0 F U w C) n z Q z Q n \ FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/5/24 Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 jo PROJECT: 0 PLURIS HAMPSTEAD VWVTP J .5 MGD MBR EXPANSION IL CD CLIENT: z PLURIS HAMPSTEAD, LLC PO BOX 297 J_ HAMPSTEAD, NC 28443 J Project Sheet 0 1 z 0 Date 6/5/24 Scale 1 4 = 1 C15 J SW ELE. = 47.5 (TOP OF STEPS) SW ELE. = 47.5 (TOP OF STEPS) ° \-I 12' ROLL UP DOOR I SOUTH ill = 11 u d ° a d a ' CONTROL BLDG SLAB/SW ELE. = 45.0 WEST 111 = 11 CONTROL BLDG SLAB/SW ELE. = 45.0 ° a a a ° ° d ° ° ° . d'° ° e n 12 R30 INSULATION OVER CONDITIONED SPACE ONLY '12 "GYPSUM CIELING IN CONDITIONED SPACE ONLY CONTROL BLDG SLAB/SW ELE. = 45.0 TOP OF TANK WALL ELE. = 51.0 d SW ELE. = 47.5 (TOP OF STEPS) MANUFACTURED ROOF TRUSSES BY OTHERS FASTENERS FOR UPLIFT TO BE SPECIFIED BY MANUFATURER 2 '12 " OSB SHEATHING MIN. W STANDING SEAM METAL ROOF PER OWNER 6" HARD YBOARD FASCIA If 12" OVERHANG DOUBLE 2 X 6 TOP PLATE SOFFIT TO BE CEMENTIOUS FIBER BOARD OR VINYL R19 INSULATION TYP IN EXTERIOR AND INTERIOR WALLS SURROUNDING CONDITIONED SPACE 2 X 6 SPF STUDS 12 " OC TYP. '12 " OSB SHEATHING INTERIOR FULLYBLOCKEDAND NAILED W 8d NAILS 3" ON THE EDGE AND 6" IN THE FIELD AND BUILDING WRAP TYPICAL CONCRETE EQUIPMENT PAD TO BEA MINIMUM OF 3"ABOVE FINISHED FLOOR PAD SHALL EXCEED EQUIPMENT OUTLINE DIMENSIONS BY 3' ON ALL SIDES 112 " OSB SHEATHING EXTERIOR FULLY BLOCKED AND NAILED W 8d NAILS 3" ON THE EDGEAND 6" IN THE FIELD AND BUILDING WRAP NOTE: USE z " PT PLYWOOD ON ETERIOR WALL FACING TANK 0 HARDYBOARD OR EQUIVALENT LAP SIDING PER OWNER 18"X 8" CONCRETE PANEL RISER IN CONTROL ROOM ONLY DOUBLE PT 2 X 8 6"3500 PSI28 DAY SILL PLATE CONCRETE SLAB 1� 1� SLOPE GRADE AWAY FROM BUILDING TYP. a%a� a%A a%d VAPOR BARRIER 6"COMPACT STONE UNDER SLAB COMPACT EARTH COMPACT EARTH TURNED DOWN SLAB W/2 #5 BAR 24„ CONTINUOS. INSTALL '12 " 'T' HOOKS 48" OCAND AT EACH CORNER AND ON EACH SIDE OF ALL OPENINGS TYPICAL WALL SECTION NTS I r 0 0 \11 (2) 3068 EXT. DOORS I NORTH 111 = 11 EAST 111 = 11 /A SW ELE. = 47.5 (TOP OF STEPS) SW ELE. = 47.5 (TOP OF STEPS) Q LU r) J J Q J Q U_ L.� U) z O Q W J LU z J M� W J O L.I. z O U 6 General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 PROJECT: PLURIS HAMPSTEAD VWVfP .5 MGD MBR EXPANSION CLIENT: PLURIS HAMPSTEAD, LLC PO BOX 297 HAMPSTEAD, NC 28443 1� Project Sheet Date 6/5/24 C16 Scale 1/4)) = 1 > 1r FINE SCREEN ROOF PLAN 1/4" = 1' 4'-0 3/8" 5'-10 7/8" 6'-0 3/4" SCREEN DRAIN GRINDER STATION I --�o I10" DIP IF-0011, 110" DIP IF-001 GV-101 GV-102 I I � O I M r Is-o2 8'-0" \ p I E+ p i k 1 E ® �3 EI ®, I cP-ol CONCRETE DUMPSTER PAD V ►_ 0 FINE SCREEN PLACEMENT PLAN 1/4" = 1' SIMPLEX GRINDER STATION SEE DETAIL ON SHEET C4.1 RIM EL. 6 ABOVE GRADE 12" PVC-PW-002 2'-11 3/8" CO 0000 - \O os •l Ool o O 00000 o o0oos�= 0�8�8�8�8�% ,ogo O Lf) ,--io 8" PVC-SCOF-00_ I I � II I1" SCED 80 PVC cv - XV M M M I1" SCED 80 PVC- PW-002 4'-0 5/16" 5'-10 7/8" HEAT TRACING NOTE: ALL ABOVE GRADE WATER SUPPLU AND INFLUENT LINES ARE TO BE HEAT TREACED AND INSULATED. 1 SC EN PAD/COMPACTOR DRA N 4" PVC Ji 8" FLOOF_ DRAIN W GRATE REDUCE TO 4" 6'-0 13/16" FINE SCREEN PLUMBING PLAN 1/4" = 1' General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 NOTE: DISTANCES BETWEEN DISCHARGE PIPES AND SUPPORTS AND BETWEEN THE FINAL PLAN - NOT RELEASED FOR COMPACTOR AND REA 12 123 CONSTRUCTION SCREEN SUPPORTS ARE TIGHT. CONTRACTOR TO C SRo�;�.,,, VERIFY ALL PEDASTAL I I a LOCATIONS PRIOR TO 2 72 � POURING.IN a, 4'-0 3/8" 5-10 7,(8" 6'-0 3/4" 16 -0 = _ _ — in Is-o1 Is-o2 6/5/24 I 8" X 25" CONCRETE SCREEN SUPPORTS CP-01 10" _ _ r fV No. Revision/Issue Date SW EL. 50.751 Ln ,/ T. I 41-0 3/8" 5'-10 7/8" 6'-0 3/4" IEL. 50.75� ,,, ,zz� 6ezzl ` :a 'V f .• } I- zzz -'g/ zzz 0 x K/0o� ,,,,,,,,,,,,,,,,,,,,,,,� n MICHAEL C. GALLANT PE PA o,,gogogogogogo PO BOX 4039 41-0 3/8" 5'-10 7/8" 6'-0 3/4" 116"PVCDRAIN — SURF CITY, NC 28445 - - - - 18' X 8' DUMPSTER PAD FLEXIBLE COUPLING p 910-448-1046 ON PRESS DISCHARGE M I I I I 13" PVC PRESS DRAIN INV. 47.5 �. gallantmc@yahoo.com 14" DRAIN LINE NC FIRM#: C-1989 �I 6" X 43" SCREEN O 12" X 22" HEAT TRACING NOTE: COMPACTOR Ln ALL ABOVE GRADE WATER SUPPLU ° . `PROJECT: r RI r r AND INFLUENT LINES ARE TO BE PLURIS HAMPSTEAD WWTP HEAT TREACED AND INSULATED. u .5 MGD MBR EXPANSION 8'-2 3/8" 4'-7 1/16" CLIENT: m' PLURIS HAMPSTEAD, LLC 3'-2 9/16" PO BOX 297 FINE SCREEN END SECTION 1/4" = 1' U) HAMPSTEAD, NC 28443 C Z \ >� W - \D w Project Sheet p. FINE SCREEN PAD EQUIPMENT SUPPORT PLAN 1/4" = 1' U Date 6/5/24 C4m0 ' p C p D A p W Scale » z 1> ' 1� 12 3L STANDING SEAM METAL ROOF ROOF FRAMING TO BE TO MATCH EQU. CONTORL BUILDING MANUFACTURED TRUSSES WITH 12 SIMPSON H2 CLIPS AT EACH \�3 � TRUSS/GIRDER LOCATION (2) 2 X 10 PT BAND CONTAINMENT 161_011 LIP ELE. 51.25 sw GRADE SLOPE TO DRAIN � ELE. 50.75 �. FASCIA TO MATCH EQUIP./CONTROL BLDG. SEE DETAILS ON SHEET C4.2 FOR TYPICAL PILE TO BAND CONNECTION 6 x 6 PT PILING TYP. CONTAINMENT DYKE TO BE 8" HIGH AND 8" WIDE CONTINUOS AROUND PAD PERIMETER TYP. 10" DIP-INF-001 1" SCHED 80 PVC- PW-002 8" PVC-SCOF-001 SIMPLEX GRINDER STATION SEE DETAIL ON SHEET C4.1 RIM EL. 6" ABOVE GRADE GRADE 50.75 h 2" PVC-PW-002 2" PVC GRINDER STATION EFFLUENT. ,-� PLUMB TO SCREEN INFLUENT 6" THICK FLOOR SLAB 3,500 PSI 28 DAY CONCRETE WITH 6 X 6 WWF REINFORCEMENT TYP. MINIMUM BURY DEPTH PAD TO BE PLACED ON A MINIMUM OF CENTER DRAIN ELE. 50.5 81 8 FT BELOW GRADE TYP. 12" OF COMPACT #57 STONE FINE SCREEN SHED FRAMING SECTION 3/8" = 1' GRINDER STATION INLET INVERT EL. 46.92 BV-101,201 SV-101,201 10" FELX. CONNECTOR 10" PVC GV-101,201 FELX. CONNECTOR.TYP. 12 12 3L_" ]3 �o �{CP-01� 07 d ♦ } \• . . d. d' SCREEN SUPPORT EL. 52.55 BV-301 SV-301 COMPACTOR SUPPORT EL. 51.24 d • a; 4 COMPACTOR DRAIN CONNECTION 8" FLOOR DRAIN W GRATE REDUCE TO 4" V SCHED 80 PVC-PW-002I 8" PVC SCREEN OVERFLOW INVERT EL. 48.40 NOTE: THE PAD DRAIN LINE TEES INTO THE OVERFLOW LINE HERE FINE SCREEN PLUMBING SECTION 3/8" = 1' 2" PVC VENT W BUG SCREEN AND FLAPPER CHECK VALVE REMOTE MOUNTED SIMPLEX CONTROL PANEL 72" MIN 1 1/2" CONDUIT FLANGE STRUCT. PLASTIC GRADE ELE 5075 TOP RAIL SUPPORT SST� BASIN COVER, SOLID STRUCTURAL PLASTIC /RIM ELE 1 5 RAIL SUPPORT FLANGE, SST H �_ \ VALVE EXTENSION HANDLE I I/2"CONDUIT REQ-D. " INLET FITTING (FIELD INSTALLED) GUIDE RAILS, I" SCH. 10 SST INVERT ___-IN2"GDI ARGE ELAGEQ(82JRON ELE 46.92 _ DISCHARGE LEVEL HIGH WATER "ALARM" LEVEL INV ELE - --LIFTOUT CHAIN, I/4" SST LIFT BAIL, SST - - -1 1/4" DISCHARGE PIPE, PVC (AS REQ'D.) \` PUMP "ON" INV ELE 575 36" DIA FIBERGLASS BASIN .. PUMP "OFF" INV ELE 56 5 UFTOUT (W/CHECK VALVE) - n� STATION BOTTOM INV ELE 5525 GRINDER PUMP CONCRETE ANTI -FLOTATION BASE REQUIRES SHOWN 1' RING I' DEEP AROUND STATION BASE I. MANUFACTURER MUST BE APPROVED BY PLURIS. 2. GRINDER PUMP TO BE MEYERS V2 SINGLE PHASE 3. MOUNT SIMPLEX CONTROL PANEL ON A 6 X 6 PT POST IN CLOSE PROXIMITY TO THE STATION. 4. NO ELECTRICAL CONNECTIONS INSIDE OF WET WELL. ALL FLOAT AND PUMP CORDS TO TERMINATE IN THE CONTROL PANEL ONLY. 5. ONE (1) GRINDER PUMP PLUS ONE (1) SHELF SPARE SHALL BE SUPPLIED FOR REDUNDANCY. MIN 2' BELOW GRADE TYPICAL SIMPLEX GRINDER STATION DETAIL NOT TO SCALE MOUNTING SST. CHARGE FLANGE VALVE, PVC ION VALVE, PVC l General Notes �- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ,p�a fCARn�i 29572 c� C G nm nn 6/5/24 No. Revision/Issue Date, MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 `PROJECT: PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION CLIENT: PLURIS HAMPSTEAD, LLC PO BOX 297 U) HAMPSTEAD, NC 28443 Z \ 3/8-16UNC X 2 LG ANCHOR STUD UJI (4) REQ'D Project Sheet Date 6/5/24 Scale 1 4 = 1 C4m 1 J DETAIL NO. 9 — TYPICAL PORCH HEADER CORNER CONNECTIONS SCALE: 0.75" = 12" OVERHEAD VIEW 3/16" X 4" X 18"L GALV. STEEL STRAPS �- 5/8"DIA. X 10" GALV. STEEL BOLTS HEADER 2.5' HEADER 8"X8" PT PORCH POST 2" INSIDE VIEW HEADER, NOTCHED INTO POST HEADER, NOTCHED INTO POST. r E E \5/8"DIA. X 10" E.�� GALV. BOLTS 3/16" X 4" X 18"L — GALV. STEEL STRAP ����8"X8" PT PORCH POST o/. 8'-101 01'-016" 3'-43,) 4' — 416 W W GENERAL NOTES 1: SPECIFICATIONS FOR THIS SITE ONLY 2: UNLESS STATED OTHERWISE ALL LUMBER SPECIFIED AS NO.2, SYP. USED AT 19% MAX. MOISTURE CONTENT, PRESSURE TREATED WHERE EXPOSED. 3: LVL MATERIAL IS SPECIFIED AT MINIMUM GRADE: E-2.0 Fb-2950. LVL MATERIAL MANUFACTURED BY OTHERS OF EQUIVALENT SPECIFICATION IS ACCEPTABLE. 4: HANGERS SPECIFIED AS SIMPSON STRONG TIE, INC. INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. OTHER HANGERS OF EQUIVALENT DESIGN AND LOAD RATING ARE ACCEPTABLE. 5: THE APPLICABLE BUILDING CODE FOR THIS PROJECT IS THE NORTH CAROL- NA STATE BUILDING CODE, VOLUME VII RESIDENTIAL. 6: ANY CHANGES TO THE STRUCTURAL SPECIFICATIONS SHOWN HERE IN ARE TO BE MADE UPON WRITTEN APPROVAL OF THE ENGINEER. STRUCTURAL LOADS: IT IS THE SOLE RESPONSIBIMTY OF THE FLOOR DEAD LOAD -20PSF CONTRACTOR AND/OR BUILDER TO CONFORM TO ALL STANDARDS , PROVISIONS, REQUIREMENTS, FLOOR LIVE LOAD -40PSF METHODS OF CONSTRUCTION AND USES OF MATERIALS PROVIDED IN BUILDINGS AND/OR WALL DEAD LOAD -10PLF/F STRUCTURES AS REQUIRED BY N.C. UNIFORM BUILDING CODE, LOCAL AGENCIES AND IN ROOF LIVE LOAD -20PSF ACCORDANCE WITH GOOD ENGINEERING PRACTICES, VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION, ROOF DEAD LOAD - 20 PSF SNOW LOAD - 10 PSF ALL ELEVATIONS TO BE VERIFIED BY A NC PLS NOTE: STRUCTURE LOADED FOR WIND PRIOR TO CONSTRUCTUION. NOTE THAT FLOOD MAPS MAY SHEAR & UPLIFT @ 140 MPH. 3 CHANGE AND REQUIRED ELEVATIONS MAY DIFFER FROM THOSE LISTED HERE. SEC. GUST ACCORDING TO ASCE 7 CONSULT A NC PLS BEFORE PILINGS ARE SET AND PRIOR TO FIRST FLOOR GIRDER PLACEMENT. DETAIL NO. 10 — TYPICAL HEADER TO POST CONNECTION SCALE: 0.75" = 12" 5/8"DIA. X 10" GALV. STEEL BOLTS HEADER O® 91, '_STRAP; 3/16" X 4" X 18"LONG GALV. STEEL, ONE STRAP, 4„ OUTSIDE FACE OF JOINT. 8"X8" PT PORCH POST �\ — 1 7t" ;.M7 DETAIL NO. 11 — TYPICAL HEADER TO POST WITH BUTT JOINT CONNECTION DOUBLE BUTT JOINT SCALE: 0.75" = 12" 5/8"DIA. X 10" GALV. STEEL BOLTS O HEADER O® ®p STRAPS; 3/16" X 9" OO ®O, 2" X 18" GALV. STEEL, TWO STRAPS OUT SIDE FACE OF OO O JOINT. 3.25"-------3.25" 8"X8" PT PORCH POST 66 A IL A G), a 611 A 6111 A 3 4 5 Y 18'-11 )" 5'— 108 qj 4 t 1 5 8 90481 SCREW M6S A4 M10x30 1 1 4 8 91766 WASHER RB A4 M10 1 1 3 1 105-1354 LIFT PIPE SCP 220 1 1 2 1 105-S2-21 SCREW CONV. PRESS SCP 220 1 1 1 2 302-S24 DRUM SCREEN RS 24 1 Iltem QTY Part Number Description Material Comments 1 E6-4 Z V I . L 0 �d m7984 ecu University Avenue NE F Fridley, MN 55432 Ci Tel.: (866) 929.7773 WATER 5 D LU T CI N 5 www.cleantekwater.com Z ., Drawn by: AP Date 12/21/23 3rd Angle Projection O Chk'd by Vote: Z r— Approved by, Date, THIS PRINT IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF CLEANTEK WATER SOLUTIONS, Title: LAYOUT DRAWING 2 X RS-24 & SCP-220 W/ LIFT PIPE Project: Part #: Drawing #: 24-0000-101 Sht: 1 OF 1 Scale: 3/4"=1' REV: _ 6 General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, INC 28445 910-448-1046 gallantmc@yahoo.com INC FIRM#: C-1989 `PROJECT: PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION CLIENT: PLURIS HAMPSTEAD, LLC PO BOX 297 U) HAMPSTEAD, NC 28443 Z mo/w+ Project Sheet 0 U Date 6/5/24 C4n2 LL1 Z Scale 1 4 = 1 1x-o i PRIt-AI TOXIC BASIN 6" DIP-IR-0621 S �10" DIP-RAS-0021 3' WIDE SLIDE GATE W INVERT = 48.2 CENTER GATE ON PA TANK WALL ENVIROMIX SYSTEM SEE ENVIROMIX DETAIL SHEETS FF / IR PUMPS YH IPG-110201K P-11-03 I CV-11031 IPV-1107�--� IPV-1111 IF E120202 I PV-1103 a -7EJ 1 PA-02 PRE -AERATION BASIN ALL IR/FF PIPING TO BE DIP EXCEPT FOR DROP PIPES INTO TANKS WHICH CAN BE SCHED I 3' WIDE SLIDE GATE 80 PVC INVERT = 48.2 CENTER GATE ON PA TANK WALL PA-01 CC," PRE -AERATION BASIN I o 10" DIP-RAS-001 1.5"-CA-SS PV-I1o9 ALL SLIDE GATE INVERTS AT 48.2 T VALVES UPPER ELEVATION AT 18.5 SWD LOWER ELEVATION AT 17.0 SWD TRAVEL 18" SET AT 17.5 SWD 1 FE120102 I PV-1102 IPV-1106 CV-1102 I PG-1101021--' P-11-02 P-11-04 PG-1102021 CV-11041 PV-11081 �PV-1104 u ri 10"-PVC-IR/FF-002 FE1102011 PV-11121 o ENVIROMIX SYSTEM SEE ENVIROMIX DETAIL SHEETS r1 EMX-Z VM-1 L j! �z 0 n fiz ENVIROMIX SYSTEM SEE ENVIROMIX DETAIL SHEETS 110"-PVC-IR/FF-01 PV-11011 IPV-1105I J CV-1101 1 -----IPG-1101011 FF / IR PUMPS PLAN 1/4 1' o I 1.5"-CA-SS, 6"-PVC-- 1F-001I J L1 FE1101011 `jPV-1110 10"-DIP-RAS-002 BELOW GRADE YH fi TV-1102 MB-02 MBR BASIN 3' WIDE SLIDE GATE INVERT = 48.2 PLACE EDGE OF GATE STRUCTURE 6" FROM WALKWAY EDGE 3' WIDE SLIDE GATE INVERT = 48.2 PLACE EDGE OF GATE STRUCTURE 6" FROM WALKWAY EDGE I ENVIROMIX SYSTEM I SEE ENVIROMIX DETAIL SHEETS MB-01 MBR BASIN 10"-DIP-RAS-001 BELOW GRADE 1" PVC DRAIN LINE PLUMB ALL ENVIROMIX DRAIN LINES TO 1" PVC LINE UNDER THE SLAB AND SIDEWALK AND DAYLIGHT DOWNGRADE PAST THE SIDE WALK General Notes �- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 11///, S L 2 72 'qF` ICN� G ���Im 1 nn��`�• 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 w SURF CITY, NC 28445 1 910-448-1046 Q gallantmc@yahoo.com w NC FIRM#: C-1989 Q J U) `PROJECT: \ (n PLURIS HAMPSTEAD WWTP Q .5 MGD MBR EXPANSION ry W CLIENT: J PLURIS HAMPSTEAD, LLC U PO BOX 297 UHAMPSTEAD, NC 28443 W Project Sheet \ J Q z Date 0� 6/5/24 C5m0 W Scale 1 8 = 1 » > Z \ r� � D INV 47.81 a p TRANSITION FROM DIP p n TO PVC HERE . � c D p D D 0 6"-PVC-IR-001 TERMINATE PVC DROP 12" p FROM TANK FLOOR TYP. p BRACE TO TANK WALL EVERY D PAX-01 PRE -ANOXIC BASIN 6"-DIP-IR-001 0 d. . . .v..a .a. v. 'w 3' WIDE SLIDE GATE INVERT = 48.2 ALL SLIDE GATE INVERTS AT 48.2 T VALVES UPPER ELEVATION AT 18.5 SWD LOWER ELEVATION AT 17.0 SWD TRAVEL 18" SET AT 17.5 SWD ENVIROMIX SYSTEM SEE ENVIROMIX DETAILS IN APPENDIX I 10" DIP-RAS-001 INV 32.2 PIPE CENTER 3'-9" ABOVE WALL J EMX-Z VM-1 F PIPE CENTERD ON TOP OF WALL TRANSITION FROM DIP TO PVC HERE I ' r 10"-PVC-IR/FF-01 TERMINATE PVC DROP 12" FROM TANK FLOOR TYP. BRACE TO TANK WALL EVERY 3 FT MIN. .o fl n D D; c D p G PA-02 PRE -AERATION BASIN SECTION 'A' 4" = 1' LK � oDo IFE120102 JPV-1109 �PV-1102 SW ELE. = 47.5 i La w 10" DIP-RAS-001 0 ENVIROMIX SYSTEM SEE ENVIROMIX DETAIL SHEETS TRANSITION FROM DIP A3' WIDE SLIDE GATE TO PVC HERE INVERT = 48.2 A D C 7 6"-PVC-FF-001 TERMINATE PVC DROP ENVIROMIX SYSTEM 12" FROM TANK FLOOR SEE ENVIROMIX DETAILS TYP. BRACE EVERY 3' MIN. ° IN APPENDIX I D ENVIROMIX SYJTF),4- SEE ENVIROMIX D ''I AILS IN APPF-"IX 1 TV-1101 EMX-REC-1 1 EMXCOMP-1 I r n 10 -DIP-RAS-001 p INV 32.2 . . p D Q p o p P. c o p [> p AXP-01 POST ANOXIC BASIN FE110101 1 PV-1110 1 w W I i� �PV-1101 � a a w PIPE CENTER ALIGNED WITH TOP OF WALL S SECIION'B" 4' = 1' SW ELE. = 47.5 MB-02 MBR BASIN TV-1101 1 10"-DIP-RAS-001 z 4 General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION �N CARO S L 2 72 �qFIN. ' � ���. 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 w SURF CITY, NC 28445 1 910-448-1046 Q gallantmc@yahoo.com w NC FIRM#: C-1989 J `PROJECT: w 6 PLURIS HAMPSTEAD WWTP Q .5 MGD MBR EXPANSION ry W CLIENT: J PLURIS HAMPSTEAD, LLC U PO BOX 297 UHAMPSTEAD, NC 28443 W Project Sheet \ J Q z Date 6/5/24 C5m 1 0� W » > Scale 1 8 = 1 Z \ FB-08-02 I I PA--OZ PRE. -AERATION BASIL! (91D PF;E-AE .ATION B. SiN FB-08-01 B PLAN 1/411 = 1' 8" 304SS-PA-002 J 8" 304SS-PA-001 MB-02 MBR BASIN MB-01 MBR BASIN fi ' PIT 150201 BV-1502 PA BLOWER (DUTY) IBA-1502 L� IBA-1403 PIT 150101 BV-1501 s =MIE BLOWER (S.B.) BF-1504 `1 BF-1502 CONTROL BLDG BF-1503 I BF-1501 I PA BLOWER (DUTY) `1 BA-1501 A 4 General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION Q S I_` ' 1 = 2 72 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA J PO BOX 4039 n SURF CITY, NC 28445 n 910-448-1046 Z) gallantmc@yahoo.com U) NC FIRM#: C-1989 Q `PROJECT: \ PLURIS HAMPSTEAD WWTP W U) .5 MGD MBR EXPANSION Z) IL CLIENT: IL PLURIS HAMPSTEAD, LLC r) PO BOX 297 z HAMPSTEAD, NC 28443 O >/ Project Sheet \ w Date 6/5/24 C6m0 Q WScale 1 /4" = 1 ' A O N D D L D 8" 304SS-PA-001I D D p D p D > F13-08-01,02 ° PIT 150101,201 � BV-1501,2 � A8"-304SS-PA-001,002 B-15-0' D p� _ -1 EXP COUPLING 00 TYP. �. 131-011 k It ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ° > n n n' a� Y.° D D D D D ° C d D P. G ° D; D D D PA-02 PRE -AERATION BASIN SE(, I ION 'A' 4' = 1' La _ v d AXP-01 POST ANOXIC BASIN �8" 304SS-PA-001I v — G I d d w SEC I ION "B1 111 11 MB-02 MBR BASIN G .d d . A. u BF-1501,02 P D. A l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION �Si S L 2 72 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA J PO BOX 4039 n SURF CITY, NC 28445 n 910-448-1046 Z) gallantmc@yahoo.com U) NC FIRM#: C-1989 Q `PROJECT: PLURIS HAMPSTEAD WWTP W U) .5 MGD MBR EXPANSION Z) IL CLIENT: IL PLURIS HAMPSTEAD, LLC r) PO BOX 297 z HAMPSTEAD, NC 28443 O >/ Q .4,0ject Sheet w Date 6/5/24 C6m 1 Q WScale 1 /8" = 1' A T 1 r A r C� o 0 0 — — ° Ei o 0 0 4'-0" 3 SPACES @ 5'-0" = 15'-0" s C� 4'-0" IB-14-02 PERMEATE PUMP (DUTY) MBR ff P-13-02 BLOWER _----� CV-1302 FE 140201 —144 FE 140101 P-13-03 S PERMEATE PUMP (S.B.) CV-1303 Z P-13—01 EATE PUMP (DUTY) jCV-130 MBR PLAN 1/4" = 1' (DUTY) BF-1404I BF-1402I ONTROL BLDG BLOWER B-14-03 (S. B. ) MBR =EU:I: BLOWER BF-1401 � (DUTY) BF-1403 B-14—01 I f— A T 4 General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ,p�a fCARn�i 6/5/24 No. Revision/Issue Date, MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 `PROJECT: \ PLURIS HAMPSTEAD WWTP z .5 MGD MBR EXPANSION Q J CLIENT: PLURIS HAMPSTEAD, LLC PO BOX 297 z HAMPSTEAD, NC 28443 W / 7 ILL AeProject Sheet \ D 0 W Date 6/5/24 CTO r 00 Scale 1 8 = 1 NOTE BV-1001A,B (2" VENT VALVE TO ATMOSPHERE ABOVE BASIN WATER LINE) NOT I SHOWN IBF-1002A B BF-1010A,B IBF-1012A B BF-1003A,B I CONTROL BLDG FE 140101 201 IBF-1001A,B IBF-1009A,B BF-1011A,B PIT 140101,201 BF1004A,BI BV-1401,02 gr BF-1008A,B IBF-1007A,B BF-130516 6"-304SS-SCA-001,002 IBF-1J J S J J i S BF_100. ,A,B IBF-1307,8 � BF-1301,2 D CV-1301,2,3B-14-01,02 IBF-1403 BF-1303,4 P-13-01,02,03I EXP COUPLING TYP Q " n NOTE: 8" PERMEATE HEADER INVERT THROUGH WALL = 46.89 MB-01,02I D . D' w w D • AXP-01 POST ANOXIC BASIN BF-1005,6,7,8,9,10,11,12A NOTE: THESE VALVES ARE TO HAVE EXTENDED HANDLES ABOVE THE WATER LINE MB-02 MBR BASIN MBR SECTION 'A' 1/4" = 1' IBF-1001,2,3,4A BF- 1001,2,3,4B ®II lip Q, n V n - ' MB-02 �� � III II II I I II II t � .a III II II II �II I " ' �� � III III III III III II II II II II 1 III III III III III o=1II�II II �II�II �I . o� II II II II II 4 � - II II II n a SECTION ' C' 4" = 1' . p C, "d ff CL OF SS AIR HEADER 8' OFF FLOOR BF-1401,02 t V LA A p D D C' p BF-1005,6,7,8,9,10,11,12B NOTE: THESE VALVES ARE TO HAVE EXTENDED HANDLES ABOVE THE WATER LINE II �� o ba ,a a I FE 140101 I CV 130101 1 FE 130101 h IBF 1307 �— BF 1305 CV-1301 P-13-01 zlp-13-03 Al a v a BF 1301 NOTE: INSTALL PG 130101,201,301- ON INLET SIDE OF PUMP ASLO INSTAL PG 130102,202,302 ON ALL PUMP OUTLETS TYP OF ALL 3 PUMPS NOTE: INSTALL z" PVC BALL VALVE HERE ON BOTOM OF 4" PERMEATE LINE V-1301 FOR TURBIDITY METER FEED FE 140201 CV 13 201 z" POLY LINE FOR TURBIDITY SKID FEED d CV-13021 �BV-16031 —IuF rim \ CIP CONNECTION / I" SCHED 80 PVC DRAIN FOR TURB. SKID 4" -PVC-PERMEATE INVATWWLS=42.0 MBR SECTION 'D' 1/4" = 1' C l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION �N CARO ., S L 2 72 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 D d ' ^ `PROJECT: Z Q PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION .p P\(;�JPi°C W CLIENT: U) PLURIS HAMPSTEAD, LLC I- PO BOX 297 Z HAMPSTEAD, NC 28443 W Project Sheet 0 W Date 6/5/24 CIT 1 0. m Scale 1 /8„ = 1 > J CONTROL BLDG 1" PVC DRAIN FROM TURBIDITY METER HALLIDAY SERIES S1R ACCESS DOOR S1R2436 CAST IN PLACE MIN OPENING 24" X 36" 2" SCHED 80 PVC PLUMBING BV-10102,202 CV-10102,202 IEL. 45.0� _ n n D 1 13" PVC-PW-001 13" PUSH ON COUPLING 13" ENLARGER 48" X 48" PRE CAST se WW LS RIM WW LS EFFLUENT NNW = 12" PVC (GRAVITY) INV = 45.0 HP-10-01 PULL HANDLE / S" HOOK �SS LIFTING CHAIN > 2" SCHED 80 PVC D 2" SS PITLESS ADAPTER VALVE VAULT 4" PVC PERMEATE PUMP EFFLUENT 14" PVC WELL CASING 112" MIN. COMPACT STONE INV. =41.5 ISS SUPPORTS TYP. SS GUIDE RAIL SUPORT FLANGE ASSEMBLY BY PUMP MANUFACTURER F D. MIN. 12" FLANGE IP-10-01,02 P-10-03,04I pa WW LS BOTTOM EL. = 37.0 WW LIFf STATION el 2" SS 2" PUSH ON COUPLING HALLIDAY SERIES S1R ACCESS DOOR S1R2436 CAST IN PLACE MIN OPENING 24" X 36" 48" X 48" PRECAST VALVE VAULT VAULT RIM 6" ABOVE GRADE �2" SCHED 80 PVC PLUMBING 13V-10101,201 CV-10101,201 �2" PVC-PW-0021 �2" PUSH ON 11 ;, COUPLING lip. 12" MIN. COMPACT STONE WW LIFT STATION 10' DIAM. PRE CAST WET WELL JRE WELL CASING TO WET WELL I SS SUPPORTS MIN. 12" COMPACT #57 STONE WASHWATER LIFT STATION SECTION 1/4" = 1' 3 SCHED 80 PVC PLUMBING BV-10202 CV-10202 3" SCHED 80 PVC PLUMBING BV-10102 CV- 10102 12" PVC EFFLUENT TO HRI BASINS (GRAVITY) f P-10-04 P-10-01 P-10-03 �� P-10-02 WW LS DUPLEX CONTROL PANEL CIP SKID — — PRV-1601, BF- 1601,"' CHEMICAL INJECTION QUILL 4" ROTOMETER, 3" INLINE MIXER, BV-1602, BF-1602 1" PVC DRAIN 4" PERMEATE PUMP FROM TURBIDITY EFFLUENT LINE METER 3" PVC - IP- 001 CONNEc TO PERMEATE HEADER I WASHWATER LIFT STATION/CIP PLAN 1/4" = 1' 51_711 CIP SKID �a PRV-1601, BF- 1601,"' CHEMICAL INJECTION QUILL 4" ROTOMETER, 3" INLINE MIXER, BV-1602, BF-1602 3 PVC - CIP- 001 CONNECT TO PERMEATE HEADER ° ° V 3" PVC FEED FROM WASHWATER LIFT STATION P-16-01,02 PS-10-01 HP-10-01 2" PVC-PW-002 2" SCHED 80 PVC PLUMBING BV-10102 CV-10102 �2" SCHED 80 PVC PLUMBING BV-10201 CV-101201 General Notes �- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ,p"',a fCARn"", c� C G 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 U � O`PROJECT: PLURIS HAMPSTEAD WWTP Q.5 MGD MBR EXPANSION (n CLIENT: I-- PLURIS HAMPSTEAD, LLC ILL. PO BOX 297 J HAMPSTEAD, NC 28443 ry Nk w+ Project Sheet U) CIP SECTION 1/4" = 1 3: Date 6/5/24 Scale 1 4 = 1 C8m0 J 3 PVC-WAS-PRM-001 PLUMB INTO 6" INFLUENT PVC-WAS-DIG-001 FORCE MAIN y Y WITH 6X6X3TEE PV-1701 1 JFE170101�-, _ 1 B V-1702 F--� BV-1703 k--_ i SCREEN MP N) )TE SCHARGE PRESSURE GAGES ,-170101, PG 170201 NOT SHOWN S/RESCREEN JMP (S.B.) CONTROL ' BLDG WAS/RESCREEN PLAN 1/4" = 1' 121-011 181-On 4'-011 3'-011 N BV-17051 13V-17041 ,--i CV-1702 CV-1701 FE1701011201 0 PV-1701,02 II - - fV IBV-1703 BV-17021 a ' 1 2" SCHED 80 PVC TYP. 121-011 N - WAS/RESCREEN SECTION 1/4" = 1' 61-811 3" PVC-WAS-PRM-0011 /A3" PVC-WAS-DIG-00I l General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/5/24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 `PROJECT: \ PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION (D CLIENT: z PLURIS HAMPSTEAD, LLC z PO BOX 297 W HAMPSTEAD, NC 28443 W ry AeProject Sheet VJ W Date 6/5/24C900 � U) Scale 1 4 = 1 YARD HYDRANT K, YARD HYDRANT yH yH P-19-03 P-19-01 P-19-M P-19-02 n C) lJ LSL LSH I LSL LSH LE LE 0802011 � ILSL/H 060101 7)I ` �JLSL/H 0802011 � PA-02 PRE -AERATION BASIN IAE 0802011 v` DO PH TO PAX-01 I --=-=-=-=-=-=-=-=-=---=- PRE -ANOXIC BASIN I V V _ — �A I .. .. .. .. .. .. .. DO PHOO \ IAE 080101 I PRE -AERATION BASIN ------ LSL/H0801011 ,ALE 0801011 I �� LSL LSH LE 0 SECTION 'C' "' = V P-19-OS P-19-06 n n lJ I LSL LSH I 0 LSL LSL 1002011 LSL/H 09016'1 I o M B-02 MBR BASIN 0 O 4 1 — — — — — — — — — — — — — � O o — — — — — — — — — — — — — D I--L z Z O� M B-01 MBR BASIN LSL 1001011 'LSL r COMPOSITE SAMPLER (FIRE EXTINGUISHER FE CONTROL BLDG V"f FIRE EXTINGUISHER( I FE� — r PROCESS CONTROL, STEPS AND RAILINGS AND YARD HYDRANT LOCATION PLAN 1/811 = 1' CHEMICAL A _ (2)2s6s , OO� O 7' S T 0 11RIAGE NTS I 0 O A r EMERGENCY STAND BY GENERATOR CHEMICAL STORAGE SHED NOTES: 1. CHEMICAL SHEDS ARE TO BE FRAMED OF 2" X 4' PT WOOD AND SHEATHED WITH 1h" PT PLYWOOD. WALLS SHALL HAVE A DOUBLE 2 X 4 PT SILL PLATE AND A SINGLE 2 X 4 PT TOP PLATE. WALL STUDS WILL BE 16" OC. 2. EXTERIOR FINISH SHALL BE CONTRACTORS CHOICE AND BE RESISTANTTO WEATHER AND WASTEWATER EXPOSURE. 3. SHED ROOF SHALL OF SIMILAR MATERIALS TO CONTROL ROOM BLDG. 4. SHED SILL PLATES WILL BE ANCHORED TO SIDEWALK AND TANK WALLS USING CORROSION RESISTANT HILTI ANCHOR NAILS OR TAPCON FASTENERS. 5. SHED ROOF RAFTERS SHALL BE 2 X 4 PT 12" OC AND SECURED TO WALLS USING SIMPSON H10TIES. 6. THE DOOR SIDE OF THE SHED SHALL HAVE A DOUBLE 2 X 8 PT HEADER AND A VERTICAL CLEARANCE OF 7' FROM THE SIDEWALK SURFACE. 7. THE PITCH OF THE ROOF WILL BE 3" FROM THE OPENING HEADER TO THE REAR (TANK SIDE) WALL. 8. THE INSIDE DIMENSIONS OF THE SHED ARE TO BE 5' DEEP AND 6' WIDE, WITH THE DEPTH BEING MEASURED TO THE OUTSIDE TANK WALL. 9. SHEDDS SHALL EXTERIOR DOUBLE DOORS (2868) l General Notes IqL— SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ,p�a fCARn�i 29572 c� C G 6/5/24 U) z No. Revision/Issue Date FZ U O MICHAEL C. GALLANT, PE, PA J PO BOX 4039 SURF CITY, NC 28445 z 910-448-1046 NQ gallantmc@yahoo.com Q NC FIRM#: C-1989 C `PROJECT: \ 0� Q PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION J CLIENT: O PLURIS HAMPSTEAD, LLC PO BOX 297 z HAMPSTEAD, NC 28443 U'64 Project Sheet \ U) U) w U Date 6/5/24 C1000 O Scale GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this Ian sheet will result in the construction P g p P activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCGO1 Construction General Permit Sections E and F respectively). ( p Y). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. SECTION E: GROUND STABILIZATION Required Ground Stabi ization Timeframes Stabilize within this Site Area Description many calendar Timeframe variations days after ceasing land disturbance (a) Perimeter dikes, swales, ditches, and 7 None perimeter slopes (b) High Quality Water 7 None (HQW) Zones (c) Slopes steeper than If slopes are 10' or less in length and are 3:1 7 not steeper than 2:1, 14 days are allowed -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, (d) Slopes 3:1 i 4:1 14 ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed -7 days for perimeter dikes, swales, (e) Areas with slopes ditches, perimeter slopes and HQW Zones flatter than 4:1 14 -10 days for Falls Lake Watershed unless there is zero slope Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last [and disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: Temporary Stabilization Permanent Stabilization • Temporary grass seed covered with straw or • Permanent grass seed covered with straw or other mulches and tackifiers other mulches and tackifiers • Hydroseeding • Geotextile fabrics such as permanent soil • Rolled erosion control products with or reinforcement matting without temporary grass seed • Hydroseeding • Appropriately applied straw or other mulch • Shrubs or other permanent plantings covered • Plastic sheeting with mulch • Uniform and evenly distributed ground cover sufficient to restrain erosion • Structural methods such as concrete, asphalt or retaining walls • Rolled erosion control products with grass seed POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans an ans under stored equipment. Y 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at [east 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at [east 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at [east 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet awayfrom storm drain inlets sediment basins perimeter sediment controls . and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary permanent control needs. P Y or t e ,fit ,NORTH CAROLINA Environmental Quality ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER ' - o - o w r77 tea.• PERi ,i •m•a�..evar ���• s a n• r.� even Elm ABOVE GRA WASHrUT STRUCTURE HELDW GRAr� mA�HrUT STRUCTURE �.�� CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01 /19 PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF -INSPECTION Self -inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self -inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. Frequency Inspect (during normal Inspection records must include: business hours 1 Rain gauge Dail Dail rainfall amounts. () H g V Y maintained in good working order (2) E&SC Measures (3) Stormwater discharge outfalls (SDCs) (4) Perimeter of site (5) Streams or wetlands onsite or offsite (where accessible) (6) Ground stabilization measures NOTE: The rair If no daily rain gauge observations are made during weekend or holiday periods, and no individual -day rainfall information is available, record the cumulative rain measurement for those un- attended days (arc this will determine if a site inspection is needed). Days on which no rainfall occurred shall be recorded as "zero." The permittee may use another rain -monitoring device approved by the Division. At least once per 1. Identification of the measures inspected, 7 calendar days 2. Date and time of the inspection, and within 24 3. Name of the person performing the inspection, hours of a rain 4. Indication of whether the measures were operating event> 1.0 inch in properly, 24 hours 5. Description of maintenance needs for the measure, 6. Description, evidence, and date o SF(�ective ac Ions taken. At least once per 1. Identification of the discharge out ails inspecte, 7 calendar days 2. Date and time of the inspection, and within 24 3. Name of the person performing the inspection, hours of a rain 4. Evidence of indicators of stormwater pollution such as oil event> 1.0 inch in sheen, floating or suspended solids or discoloration, 24 hours S. Indication of visible sediment leaving the site, 6. Description, evidence, and date of corrective actions taken. At least once per If visible sedimentation is found outside site limits, then a record 7 calendar days of the following shall be made: and within 24 1. Actions taken to clean up or stabilize the sediment that has left hours of a rain the site limits, event > 1.0 inch in 2. Description, evidence, and date of corrective actions taken, and 24hours 3. An explanation as to the actions taken to control future At least once per releases. If the stream or wetland has increased visible sedimentation or a 7 calendar days stream has visible increased turbidity from the construction and within 24 activity, then a record of the following shall be made: hours of a rain 1. Description, evidence and date of corrective actions taken, and event> 1.0 inch in 2. Records of the required reports to the appropriate Division 24 hours Regional Office per Part III, Section C, Item (2)(a) of this permit. After each phase 1. The phase of grading (installation of perimeter E&SC ofgrading measures, clearing and grubbing, installation of storm drainage facilities, completion of all land -disturbing activity, construction or redevelopment, permanent ground cover). 2. Documentation that the required ground stabilization measures have been provided within the required timeframe or an assurance that they will be provided as soon as possible. inspection resets the required 7 calendar day inspection requirement. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours. Item to Document Documentation Requirements a Each E&SC measure has been installed Initial and date each E&SC measure on a copy PY and does not significantly deviate from the of the approved E&SC plan or complete, date locations, dimensions and relative elevations and sign an inspection report that lists each shown on the approved E&SC plan. E&SC measure shown on the approved E&SC plan. This documentation is required upon the initial installation of the E&SC measures or if the E&SC measures are modified after initial installation. (b) A phase of grading has been completed. Initial and date a copy of the approved E&SC plan or complete, date and sign an inspection report to indicate completion of the construction phase. (c) Ground cover is located and installed Initial and date a copy of the approved E&SC in accordance with the approved E&SC plan or complete, date and sign an inspection plan. report to indicate compliance with approved ground cover specifications. (d) The maintenance and repair Complete, date and sign an inspection report. requirements for all E&SC measures have been performed. (e) Corrective actions have been taken Initial and date a copy of the approved E&SC to E&SC measures. plan or complete, date and sign an inspection report to indicate the completion of the corrective action. 2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site -specific exemption based on unique site conditions that make this requirement not practical: (a) This General Permit as well as the Certificate of Coverage, after it is received. (b) Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. 3. Documentation to be Retained for Three Years All data used to complete the a-N01 and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non -surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a) The E&SC plan authority has been provided with documentation of the non -surface withdrawal and the specific time periods or conditions in which it will occur. The non -surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b) The non -surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that Must be Reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: • They are 25 gallons or more, • The are less than 25 gallons but cannot be cleaned u within 24 hours Y g P • They cause sheen on surface waters (regardless of volume), or • They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (d) Anticipated bypasses and unanticipated bypasses. (e) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (800) 858-0368. Occurrence Reporting Timeframes (After Discovery) and Other Requirements (a) Visible sediment • Within 24hours, an oral or electronic notification. deposition in a • Within 7 calendardays, a report that contains a description of the stream or wetland sediment and actions taken to address the cause of the deposition. Division staff may waive the requirement for a written report on a case -by -case basis. • If the stream is named on the NC 303(d) list as impaired for sediment - related causes the permittee may be required to perform additional monitoring, inspections or apply more stringent practices if staff determine that additional requirements are needed to assure compliance with the federal or state impaired -waters conditions. (b) Oil spills and • Within 24hours, an oral or electronic notification. The notification release of shall include information about the date, time, nature, volume and hazardous location of the spill or release. substances per Item 3(b)-(c) above (c) Anticipated • A report at least ten days before the date of the bypass, if possible. bypasses [40 CFR The report shall include an evaluation of the anticipated quality and 122.41(m)(3)] effect of the bypass. (d) Unanticipated • Within 24hours, an oral or electronic notification. bypasses [40 CFR • Within 7 calendardays, a report that includes an evaluation of the 122.41(m)(3)] quality and effect ofthe bypass. (e) Noncompliance • Within 24hours, an oral or electronic notification. with the conditions • Within 7 calendardays, a report that contains a description of the of this permit that noncompliance, and its causes; the period of noncompliance, may endanger including exact dates and times, and if the noncompliance has not health or the been corrected, the anticipated time noncompliance is expected to environment[40 continue; and steps taken or planned to reduce, eliminate, and CFR 122.41(1)(7)] prevent reoccurrence of the noncompliance. [40 CFR 122.41(I)(6). • Division staff may waive the requirement for a written report on a case -by -case basis. NCGO1 SELF -INSPECTION, RECORDKEEPING AND REPORTING NORTH CAROLINA a Environmental Quality Y EFFECTIVE: 04/01 / 19 4 General Notes SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN NOT RELEASED FOR CONSTRUCTION ```0%J1111111", .n... C A.. / '�- S 72 qFL C:.GN rp/till l lltttt\0 6/11 /24 No. Revision/Issue Date MICHAEL C. GALLANT, PE, PA NO PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 PROJECT: PLURIS HAMPSTEAD VWVfP .5 MGD MBR EXPANSION CLIENT: PLURIS HAMPSTEAD, LLC PO BOX 297 HAMPSTEAD, NC 28443 Project Date 6/11 /24 Scale 1 50 Sheet C 11,00 U AREA DESCRIPTION DATES SEEDING MIXTURE PERMANENT lb/acre 120 Rye (grain) 50 Kobe lespedeza ALL WINTER AND EARLY SPRING Dec 1 Apr 15 40 German millet ALL SUMMER Apr 15 - Aug 15 120 Rye (grain) ALL FALL Aug 15-Dec 30 VEGETATIVE PLAN SHEET - TEMPORARY SEEDING NOTES SEED BED PREP METHOD SOIL AMENDMENTS MULCH MAINTENANCE SEEDING NOTES 1. Remove rocks ad debris. 2. 1. Broadcast seed at the Follow reccomendations of soil Apply 4,000 lb/acre grain straw or equivalent Refertlize if growth is not fully Mulch and anchoring materials must not be Apply lime and fertilizer at rates recommended rate with a cyclone tests, or apply 2000 bl/acre cover of another suitable mulch. Anchor by adequate. Reseed, refertilize and allowed to wash down slopes and clog drainage recommended by soil tests; spread seeder, drop spreader, or ground agricultural limestone and tacking with asphalt, roving, or netting or by mulch immediately following devices. evenly and incorporate into the cultipacker seeder. 2. Rake seed 750 lb/acre 10-10-10 fertilizer. crimping with a mulching tool. A disk with erosion or other damage. top 6" with a disk, chisel plow, or into the soil and lightly pack to blades set nearly straight can be used as a mulch rotary tiller. 3. Break up large establish good contact. anchoring tool. clods and rake into a loose uniform seedbed. 4. Rake 1. Remove rocks ad debris. 2. 1. Broadcast seed at the Follow reccomendations of soil Apply 4,000 lb/acre grain straw or equivalent Refertlize if growth is not fully Mulch and anchoring materials must not be Apply lime and fertilizer at rates recommended rate with a cyclone tests, or apply 2000 bl/acre cover of another suitable mulch. Anchor by adequate. Reseed, refertilize and allowed to wash down slopes and clog drainage recommended by soil tests; spread seeder, drop spreader, or ground agricultural limestone and tacking with asphalt, roving, or netting or by mulch immediately following devices. evenly and incorporate into the cultipacker seeder. 2. Rake seed 750 lb/acre 10-10-10 fertilizer. crimping with a mulching tool. A disk with erosion or other damage. top 6" with a disk, chisel plow, or into the soil and lightly pack to blades set nearly straight can be used as a mulch rotary tiller. 3. Break up large establish good contact. anchoring tool. clods and rake into a loose uniform seedbed. 4. Rake 1. Remove rocks ad debris. 2. 1. Broadcast seed at the Follow reccomendations of soil Apply 4,000 lb/acre grain straw or equivalent Repair and refertilize damaged Mulch and anchoring materials must not be Apply lime and fertilizer at rates recommended rate with a cyclone tests, or apply 2000 bl/acre cover of another suitable mulch. Anchor by areas immediately. Topdress with allowed to wash down slopes and clog drainage recommended by soil tests; spread seeder, drop spreader, or ground agricultural limestone and tacking with asphalt, roving, or netting or by 50 lb/acre Nitrogen in March. If it devices. evenly and incorporate into the cultipacker seeder. 2. Rake seed 1000 lb/acre 10-10-10 fertilizer. crimping with a mulching tool. A disk with is necessary to extend temporary top 6" with a disk, chisel plow, or into the soil and lightly pack to blades set nearly straight can be used as a mulch cover beyond June 15, overseed rotary tiller. 3. Break up large establish good contact. anchoring tool. with 50 lb/acre Kobe lespedeza in clods and rake into a loose late February or early March. uniform seedbed. 4. Rake ALL SEEDING NOTES ARE DIRECTLY FROM THE 'EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL". COMPREHENSIVE INFORMATION ON SEEDING CAN BE FOUND WITH THE SPECIFICATIONS ACCOMPANYING THESE SHEETS. FOR A COPY OF THE SPECIFICATIONS CONTACT MICHAEL C. GALLANT, PE, PA. SEE TITLE BLOCK FOR CONTACT INFORMATION. 2v in Temporary Gravel Construction Entrance/Exit nts Construction Specification: 1. Clear the entrance and exit area of all vegetation, roots, and other objectionable material and properly grade it. 2. Place the gravel to the specific dimensions shown on the detail, and smooth it. 3. Provide drainage to carry water to a sediment trap or other suitable outlet. 4. Use geotextile fabrics because they improve stability of the foundation in locations subject to seepage or high water table. Maintenance Note: 1. Maintain the gravel pad in a condition to prevent mud or sediment from leaving the construction site. This may require periodic topdressing with 2- inch stone. After each rainfall, inspect any structure used to trap sediment and clean it out as necessary. Immediately remove all objectionable materials spilled, washed, or tracked onto public roadways UPON STABILIZATION OF ALL UPSTREAM AREAS ALL SEDIMENT SHALL BE REMOVED FORM THE WET DETENTION BASIN PRIOR TO BEING PUT INTO SERVICE AS A STORMWATER BMP, NOTE: SLOPE ALL FILLED AREAS @ 3: 1 & STABILIZE WITH EXCELSIOUR MAT NOTE: SEE SEEDING CHART FOR DETAILS IN STABILIZING DISTURBED AREAS, STABILIZE ALL DISTURBED AREA WITHIN 7 DAYS MAXIMUM, HYDROSEEDING NOTES: ALTERNATIVE #1 SEED & FERTILIZE ACCORDING TO SEER CHART. SPRAY PAM @ 20LBS PER ACRE. MULCH WITH STRAW @ 2 TONS PER ACRE. ALTERNATIVE #2 HYDROSEED -SEED WITH PENNINGTON OUTER BANKS MIX. -PENNINGTON JET SPRAY -20/20/20 FERTILIZER AND PENN TAC 5 OR FOR MECHANICALLY AGITATED MACHINES -70/30 BLEND BY PROFILE -18/24/12 FERTILIZER -PENN TAC 5 NCDOT #5 OR #57 WASHED STONE NCDOT WASHE, 1' MAX" HARDWARE CLOTH & GRAVEL INLETPROTECTION IN 19LA(/CE HARDWARE I I I I I INLET ALL CURB INLETS AND GRATE INLETS SHALL HAVE INLET PROTECTION INSTALLED DURING CONSTRUCTION ENERGY DISSAPATOR- ALL OUTLETS SHALL HAVE ENERGY DISSAPATORS INSTALLED PER THE SCHEDULE 11 ON THIS SHEET Steel Filter Yabnc Backfill ch mpact and compact thoroughly Natural ground j 4' 81, mm' mid 24"' I Sediment Fence Detail Cross Section View nts Sediment fence maintenance notes: 1. Inspect sediment fences at least once a week and after each rainfall. Make any required repairs immediately. 2. Should the fabric of the sediment fence collapse, tear, decompose or become ineffective, replace it promptly. 3. Remove sediment deposits as necessary to provide adequate storage volume for the next rain and to reduce pressure on the fence. Take care to avoid undermining the fence during cleanout. 4. Remove all fencing materials and unstable sediment deposits and bring the area to grade and stabilize it after the contri- buting drainage area has been properly stabilized. 24'��Po b1 t St Cross-section of porous baffle in a sediment basin Baffle construction notes Tits 1. Grade the basin so that the bottom is level front to back and side to side. 2. Install posts or saw horses across the width of the sediment trap (practice 6.62, Sediment Fence). 3. Steel post should be driven to a depth of 24", spaced a maximum of T apart, and installed up the sides of the basin as well. The top of the fabric should be 6" higher than the invert of the spillway. Tops of baffles should be 2" lower than the top of the berm. 4. Install at least three rows of baffles between the inlet and outlet discharge pomt 5. When using posts, add a support wire or rope across the top of the measure to prevent sagging. 6. Wrap porous material, like jute backed by coir material, over a sawhorse or the top wire. Hammer rebar into the sawhorse legs for anchoring. The fabric should have five to ten percent openings in the weave. Attach fabric to a rope and a support structure with zip ties, wire, or staples. 7. The bottom and sides of the fabric should be anchored in a trench or pinned with 8-inch erosion control matting staples. S. Do not splice the fabric, but use a continuous piece across the basin. Baffle maintenance notes 1. Inspect baffles at least once a week and after each rainfall. Make any required repairs immediately. 2. Be sure to maintain access to the baffles. Should the fabric of a baffle collapse, tear, decompose, or become ineffective, replace it promptly. 3. Remove sediment deposits when it reaches half full to provide adequate storage volume for the next rain and to reduce pressure on the baffles. Take care to avoid damaging the baffles during element. Sediment depth should never exceed half the designed storage depth. 4. After the contributing drainage area has been properly stabilized, remove all baffle materials and unstable sediment deposits, bring the area to grade, and stabilize it. 8' max standard strength fabric with wire fence uw NOTE: NOTE STABILIZE ALL DISTURBED AREAS WITHIN 7 DAYS OF COMPLETION OF WORK OR DEVELOPMENT. PERMANENT GROUND COVER SHALL BE ESTABLISHED WITHIN 15 WORKING DAYS OR 90 CA LENDER DAYS WHICHEVER IS SHORTER) FOLLOWING THE COMPLETION OF ONSTRUCTION OR DEVELOPMENT. TEMPORARY SOIL STOCKPILE NOTES 1. TEMPOARY SOIL STOCKPILES SHOWN ON PLAN ARE SUGGESTED LOACTIONS ONLY. STOCKPILES CAN BE LOCATED IN AREAS CONVENIENT TO THE CONSTRUCTUION PROCESS, 2, STOCKPILES ARE NOT TO BE LOCATED ON SEVERE SLOPES OR IN AREAS THAT RECIEVE FLOW FROM UPHILL RUNOFF. 3, ALL STOCKPILES ARE TO BE SLOPED AT NO MORE THAN 2:1 AND STABILIZED AS SOON AS POSSIBLE USING HYDROSEEDING. 4 STOCKPILES ARE TO BE SURROUNDED BY SEDIMENT FENCE TO PREVENT EROSION. IN THE EVENT THAT SIDE SLOPES ERODE OR FAIL AND THE SEDIMENT FENCE IS BREACHED OR SEDIMENT ACCUUMULATION IS SIGNIFICANT THE STOCKPILE SHOULD BE REGRADED AND DESTABILIZED AND THE SEDIMENT FENCE REPAIRED. Q w 0 J 0 z 0 U Z O O w z O Q U LL W CD z 0 W LI 4 General Notes \� SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN NOT RELEASED FOR CONSTRIUCTION S L E 2 72 qF� C. G P 6/11 /24 NONo. Revision/Issue Rate MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, INC 28445 910-448-1046 gallantmc@yahoo.com INC FIRM#: C-1989 N PROJECT: \ PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION CLIENT: PLURIS HAMPSTEAD, LLC PO BOX 297 HAMPSTEAD, NC 28443 /Project Sheet Date 6/11 /24 C 1 1 1 Scale 1 50 EROSION CONTROL CALCULATIONS PLURIS HAMPSTEAD WWTIF TIME OF CONCENTRATION AND RAINFALL INTENSITY 10 YR STORM RAINFALL INTENSITY Tc min Tc min Tc min TIME min in/hr PRE DURING POST PRE DURING POST PRE DURING POST STORM WATER BUA AND DENSITY CALCULATIONS 1 5 9.61 132.03 88.88 106.39 ALPHA 0.469306 0.57478 0.57478 H 2 3 3 FT 1 10 7.69 145.75 98.11 117.45 SLOPE 0.005714 0.008571 0.008571 FT/FT IBASIN INFORMATION 1 15 6.48 157.24 105.85 126.71 L 350 350 350 FT/FT IRECEIVING STREAM NAME UT OF ISLAND CREEK 1 30 4.70 181.32 122.06 146.11 m 1.667 CONSTANT FOR TURBULENT FLOW IRECEIVING STREAM INDEX NUMBER C 1 60 3.06 219.34 147.65 176.75 n 0.24 0.24 0.24 ITOTAL DRAINAGE AREA 1,253,221 SF 1 120 1.92 269.71 181.56 217.34 C 0.15 0.27 0.18 (C VALUES FOR DURING ION -SITE DRAINAGE AREA 1,253,221 SF 1 180 1.38 312.26 210.21 251.62 PRE DURING POST AND POST REPRESENT PAVED IOFF-SITE DRAINAGE AREA 0 SF 1 360 0.86 384.34 258.73 309.71 SURFACE CONDITIONS ALONG THE FLOW PATH) IPROPOSED IMPERVIOUS AREA 300,773 SF 720 0.51 486.01 327.17 391.64 THE CALCULATIONS ABOVE ARE BASED ON THE EQUATION BELOW FOR TIME OF CONCENTRATION I% IMPERVIOUS AREA 24 % Tc (MINUTES) Tc = (L / (ALPHA x (IxC/43,200)^2/3))^2/3)/ 60 I PRECONSTRUCTION INTENSITY 0.51 in/hr THIS FORMULA IS EVALUATED FOR PRE, DURING, AND POST CONSTRUCTION (IMPERVIOUS SURFACE AREA DURINGCONSTRUCTION INTENSITY 0.51 in/hr CONDITIONS. THE VALUES FOR Tc ARE TABULATED IN THE UPPER LEFT HAND TABLE. ION -SITE BUILDINGS 9,947 SF PROPOSED PLANT AND SURROUNDING SIDEWALKS PLUS PROPOSED MECHANICS' BUILDIN POST CONSTRUCTION INTENSITY 0.51 in/hr THE VALUES IN BOLD REPRESENT THE TIME OF CONCENTRATION ION -SITE STREETS 5,177 SF PROPOSED DRIVE FOR PROPOSED PLANT DRAINAGE AREA 28.77 ACRES in/hr COMPOSITE C CALCULATIONS(DURING CONSTR.) I ION -SITE PARKING 2,694 SF PARKING AND SIDEWALK FOR PROPOSED MECHANICS BUILDING C AREA PRODUCT ION -SITE SIDEWALKS 0 SF C PRECON 0.15 IMPERV. ACRES 0.98 1.11 1.0878 (OTHER ON -SITE 0 SF C DURING 0.27 GRASSED/DIRT 0.24 27.66 6.6384 IFUTURE 252,288 SF C POSTCON 0.18 TOTAL 7.7262 THE CALCULATIONS FOR RATIONAL C FOR THE ENTIRE AREA IOFF-SITE 0 SF C(DURING)=1 0.271 (NOT JUST THE FLOW PATH) ARE TO THE IMMEDIATE LEFT. (EXISTING BUA 30,667 SF EXISTING PLANT AND GRAVEL DRIVEWAY PREVIOUSLY PERMITTED Q10 PRECON 2.20 CFS THESE VALUES ARE USED TO CALCULATE THE PEAK FLOW USING TOTAL 300,773 SF Q10 DURING 3.94 CFS COMPOSITE C CALCULATIONS(POST CONSTR.) THE EQUATION Q = I'C"A. Q10 POST CON 2.67 CFS C AREA PRODUCT IMPERV. ACRES 0.98 1.11 1.0878 GRASS/LND SC AREAS 0.15 27.66 4.149 TOTAL 5.2368 C(POST)=1 0.181 SEDIMENT STORAGE AND MINIMUM SURFACE AREA CALCULATIONS AREA DISTURBED 3.60 ACRES I I I I VOLUME REQUIRED 6,480.0 CU FT(BASED ON 1800 CU FT / ACRE DISTURBED) I VOLUME PROVIDED 155,178.0 CU FT(BASED ON VOLUME OF THE PROPOSED PLANT EXCAVATION) SURFACE AREA REQUIRED 1,280.6 SQ FT(BASED ON 325 SQAURE FT/Q10 FLOW DURING CONSTR.) SURFACE AREA PROVIDED 8,621.0 SQ FT(BASED ON THE PROPOSED PLANT FOOTPRINT) W Construction Sequence Z A Pre construction meeting with surveyor, grading contractor, owners and Engineer. O NCDEQ staff will be invited to the meeting and notified prior to any land disturbing _ activities commencing. A meeting will take place involving all parties involved in the construction process. The soil erosion and storm water plans will be discussed, as well as the sequence Q and BMP's to be in place before, during and after construction. J 1. Temporary Gravel Construction Entrance/Exit U Given that the site has a gravel driveway that will remain in place and all proposed development is well inside J the property boundaries, a new temporary entrance is not warranted. The contractor will treat the existing drive as a temporary entrance and maintain it as such, removing any accumulated sediment throughout the project construction. v General Notes \� SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN NOT RELEASED FOR CONSTRIUCTION n�N .CAR/Oi */40_ S nz MAINTENANCE PLAN 3. Sediment Fencing L.L �yq•.,,,�N,,,.:���.`' A sediment fence will be erected around the project boundaries as shown on the W... 1. ALL EROSION AND SEDIMENT CONTROL PRACTICES WILL BE CHECKED FOR STABILITY Ian. This fence will stay in lace until the tract is stabilized with suitable round AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL, BUT IN NO CASE, p y p g 6/11/24 LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY TO cover and all grading is complete. MAINTAIN ALL PRACTICES AS DESIGNED. 2. ALL CONSTRUCTION ENTRANCES WILL BE PERIODICALLY TOP -DRESSED WITH AN 4. Temporary Stockpile Area ADDITIONAL 2 INCHES OF #4 STONE TO MAINTAIN PROPER DEPTH. ANY SEDIMENTTHAT A temporary stockpile area will be established using sediment fencing as shown on the plan. This area wll serve as IS TRACKED INTO THE STREET WILL BE IMMEDIATELY REMOVED. NOTE THATTHIS PLAN DOES NOT SHOW a stockpile for surplus material from the proposed plant excavation. Upon backfilling of the excavation, this area No. Revision/Issue Date A NEW CONSTRUCTION ENTRANCE SINCE THE ESTABLISHED GRAVEL DRIVE WILL SERVE AS A CONSTRUCTION ENTRANCE. will be used as a borrow area to establish the finished grades as shown on the plan. 3. DURING THE ESTABLISHMENT PERIOD, THE CONTRACTOR SHALL PAY PARTICULAR ATTENTION ry TO THE STOCKPILE AREA TO ASSURE THAT SEDIMENT DOES NOT BREACH THE SEDIMENT FENCE 5. Land Grading and Excavation O BARRIER AOUND THE STOCKPILE AREA (AS SHOWN ON THE PLAN). IN ADDTION THE CONTRACTOR The site of the proposed plant common wall tank shall be excavated. The side slopes of the excavation shall not WILL INSPECT THE DISCHARGE OF THE DEWATERING SYSTEM AND CHANGE THE SEDIMENT BAG WHEN FULL. p p p �^ MICHAEL C. GALLANT, PE, PA THE CONTRACTOR SHALL ALSO INSURE THAT THE DISCHARGE OF THE SEDIMENT BAG IS FLOWING IN exceed a slope that would pose a threat of collapse due to soil conditions. The contractor is A NON -EROSIVE MANNER AND DOES NOT CAUSE A BREACH OF THE SEDIMENT FENCE ALONG THE LOD responsible for determining a safe slope for the excavation and/or provide slope stability or sheet piling as W OR ALLOW SEDIMENT INTO THE ADJACENT WETLANDS. PO BOX 4039 necessary to ensure a safe working environment. Consideration for soils qualities, wetness and weather events SURF CITY, 9 28445 shall be made to ensure a safe working environment. After the commonwall tank construction is complete 910-448-1046 4. SEDIMENT WILL BE REMOVED FROM BEHIND THE SEDIMENT FENCE WHEN IT BECOMES and the tank is backfilled, the surrounding area will be graded as shown on the plans. The finished grade is .5 FEET DEEP ATTHE FENCE. THE SEDIMENT FENCE WILL BE REPAIRED AS NECESSARY fill and ill require additional material from a borrow area mentioned above Z gallantmcCyahoo.com in w TO MAINTAIN A BARRIER. SILT FENCE STAKES WILL BE SPACED 6 FEET APART UNLESS q �• A WIRE BACKING IS USED WITH 8 FOOT STAKE SPACING. NC FIRM#: C-1989 6. Excavation Dewatering J NO� 5. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED During the commonwall tank excavation and construction the contractor shall employ a dewatering system consisting ACCORDING TO THE SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A of well points and pumps to maintain a dry excavation. The outlet of an dewatering system shall be directed to a O VIGOROUS, DENSE VEGETATIVE COVER. p p p y y g y PROJECT: \ sediment bag to assure that sediment does not leave the site. Sediment bags will be changed as needed and inspected PLURIS HAMPSTEAD WWTP STABILIZATION NOTES throughout the project to assure that sediment stays within the project limits of disturbance. Sediment bags can be emptied .5 MGD MBR EXPANSION ALL DISTURBED AREAS WILL BE STABILIZED WITHIN 7 DAYS OF CEASE OF ANY PHASE in the stockpile area. The sediment bags will be placed per the plan so as to allow the discharge to sheet flow into the OF ACTIVITY. THIS INCLUDES SLOPES, SWALES, STOCKPILES AND ANY OTHER adjacent wetland area. The perimeter sediment fence shall between the sediment bag and the adjacent wetlands shall be Z CLIENT: UNSTABILIZED AREAS. inspected daily to assure that sediment is not leaving the limits of disturbance. If the flow from the dewatering system is 0 causing channelization or rilling, the sediment bag location can be moved and the area regraded. The contractor shall PLURIS HAMPSTEAD, LLC take precautions as required to assure that the dewatering system does not cause erosion and shall employ gravel check dams PO BOX 297 or wattles in necessary. HAMPSTEAD, NC 28443 Z N% � 7. Surface Stabilization O /Pr°eet Sheet IlkAll disturbed surfaces that are not paved/graveled are to be stabilized according to the vegetative plan. W / O Date 8. Removal of Sediment Fence 6/11/24 11,02 After all areas have been stabilized the sediment shall be removed from removed from behind the sediment fence and 0. Scale the fencing will then be removed from the site. w 1 " 50' 0:/ A:':' = �D X 1-_ �V :RO M X SYSTEM DETAILS AND P AND D D:RAW VGS NOTE: THE DRAWING SHEETS IN THIS APPENDIX ARE FROM THE ENVIROMIX MANUFACTURER AND ARE REPRODUCED HERE AS AN AID TO THE CONTRACTOR FROR INSTALLATION DETAILS AND PROCEDURES. 4 General Notes IqL- SM NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION ,p�a fCARn�i 2 T7 2 c� C G 6/5/24 No. Revision/Issue Date, MICHAEL C. GALLANT, PE, PA J PO BOX 4039 Q SURF CITY, NC 28445 910-448-1046 W gallantmc@yahoo.com 0 NC FIRM#: C-1989 w >/ Fy �`PROJECT: PLURIS HAMPSTEAD WWTP .5 MGD MBR EXPANSION U Q CLIENT: � PLURIS HAMPSTEAD, LLC z PO BOX 297 Q HAMPSTEAD, NC 28443 75 >/ ' ` AeProject Sheet \ 75 ODate 0� 6/5/24 APP 1 Scale 8 1 7 1 6 1 5 + 4 1 3 E v 06 3 A STANDARD NOTES ABBREVIATIONS 1 ALL PIPES BETWEEN COMPRESSORS AND VALVE MODULES SHALL BE THOROUGHLY FLUSHED WITH AIR OR WATER FOLLOWING INSTALLATION PRIORTO COMMISSIONING. BL BLOWERS 2 EQUIPMENTAND PIPING PROVIDED BY ENVIROMIX (EMX) ARE NOTED AS SUCH. ALLOTHER ITEMS BY OTHERS. 3 COMPRESSOR PACKAGE SHALL BE LOCATED INDOORS OR IN CONDITIONED ENCLOSURES. OUTDOOR INSTALL ACCEPTABLE UNDER CANOPY PROTECTED FROM DIRECT C CONDUCTORS SUNLIGHT AND BLOWING RAIN PROVIDED AMBIENT TEMPERATURES WITHIN COMPRESSOR OPERATING LIMITS. CA COMPRESSED AIR 4 CANOPY DESIGN GUIDELINES: CAN CANBUS CABLE BELDON 3106a_E34972 A. CANOPY SHALL PROTECT 3- 6" MI N I MUM B EYON D TH E FOOTPRI NT OF TH E COMPRESSORS. CAT CATS/6 CABLE W/ RJ45 PLUG B. CANOPY CLEARANCE ABOVE COMPRESSOR SHALL BE EQUAL TO 3' - 0"• CG COMPRESSED GAS C. PARTIAL SCREEN/SHADE WALLSHALL BE I NSTALLED ON SOUTH AND WEST WALLS TO BLOCK RADIANT HEAT FROM AFTERNOON SUN. COMP COMPRESSOR D. COMPRESSOR SHALL BE INSTALLED ON 4" CONCRETE EQUI PMENT PAD. DO DISSOLVED OXYGEN E. POSITION COMPRESSOR OPERATOR I NTERFACE TERMINAL NORTH OR WESTTO MINIMIZE AFTERNOON SUN EXPOSURE. DPI DIFFERENTIAL PRESSURE GAUGE 5 MCP RECOMMENDEDTO BE INSTALLED IN CONDITIONED CLIMATE. IF NOT POSSIBLE, A CANOPY FOR PROTECTION FROM DIRECTSUNLIGHT AND BLOWING RAIN IS REQUIRED. DR DRAIN 6 DISCONNECTS NOT PROVIDED WITH COMPRESSOR. EXTERNALTI ME -DELAY FUSE -PROTECTED DISCONNECTS REQUIRED FIXED SPEED MACHINES ANDQUICK BLOW FUSE - PROTECTED DISCONNECTS REQUIRED VARIABLE SPEED MACHINES. EMX ENVIROMIX 7 ROUTE ALL HEADER SUPPLY PI IDES BELOW THE NORMAL MI NI MUM WATER SURFACE ELEVATION AS SHOWN ON THE MECHANICAL DRAWI NGS. F CONDUCTORS FURNISHED WITH EQMT 8 AERIAL PIPING IS RECOMMENDED. ALL AERIAL RUNS SHALL BE LEVEL OR SLOPE DOWN 0.5% IN THE DIRECTION OF FLOW. THE RECEIVERS AND VCP(S) SHALLBETHE LOW FC FIELD CABLE POINTS OF THE AERIALSUPPLY PIPING SYSTEM. BURIED PIPE SHALL BE LEVEL OR SLOPE DOWN IN DIRECTION OF FLOW 0.5% TO A LOW SPOT PRIOR TO RISING ABOVE GRADE. FO FIBER OPTIC HMI HUMAN MACHINE INTERFACE 9 PROVIDE CONDENSATE BLOW -OFF AT LOW POINTS IN THE PIPING SYSTEM WHEN THE LOW POINT IS NOT LOCATED ATA RECEIVER OR VCP. HT HEATTRACING 10 RECOMMEND ELEVATING EACH STANDALONE RECEIVER APPROX 6-8" TO ACCOMMODATE CONDENSATE DRAIN PIPING AND VALVES. HTR HEATER 11 HEATTRACE AND INSULATE ALL CONDENSATE DRAINS WHEN SUBJECTTO FREEZING TEMPERATURES. IQSN IQSENSORNET 12 ROUTE DRAIN TUBING INDEPENDENTLY FROM EACH COMPRESSOR PACKAGE. TUBING FITTING SEALS SHALL BE VITON OR OTHER COMPATIBLE MATERIAL. ISB I NSTR I NSICALLY SAF E BARRIER 13 PIPING UPSTREAM OF ALLVCPS SHALL BE STAINLESS STEELOR OTHER CORROSION RESISTANT MATERIAL. IF PIPING IS NOT STAINLESS STEEL CONSULT ENVIROMIX. LE LEVEL 14 AILL. CONDUCTORS (C) 120VAC UNLESS NOTED OTHERWISE. 15 12CV AIR CONTROL VALVE SIGNALS TO EACH VALVE PANEL SHALL BE #14 COPPER W1 GROUND (7W LOAD). MCP MASTER CONTROL PANEL 16 VPN CONNECTION THROUGH PCN OR SEPARATE LOCAL I NTERN ET ACCESS FOR REMOTE STARTUP AND PRODUCT SUPPORT MOD MODULATING 17 PI PE DIAMETERS ESTI MATED BASED ON GENERAL ARRANGEMENT. PI PE DIAMETERS SHOULD BE CONFIRMED FOLLOWI NG FINAL PI PING ARRANGEMENT. MOV MOTOR OPERATED VALVE 18 VALVE MODULE SUPPLY PRESSURE NOTTO EXCEED 115 PSI. NPW NON -POTABLE WATER 19 IQSN CABLE SHALL BE SOURCED THROUGH YSI. ALTERNATIVE CABLES WILL VOID WARRANTY. O/C OPEN/CLOSE ORP OXIDATION REDUCTION POTENTIAL P P RESSURE PA PROCESS AIR PCN PLANT CONTROL NETWORK PH Ph PI PRESSURE INDICATION PLC PROGRAMMABLE LOGIC CONTROLLER LEGEND PR I NSTR UM ENT P ROBE REC RECIEVER �,{{ DC.JJ THROTTLE VALVE N CHECK VALVE RG ROLLED GROOVE RIO R EMOTE I NP UT/OUTP UT MODU LE BALL VALVE FLEXIBLE CONNECTOR SER IRS 485 SERIAL CABLE Q REDUCER/BUSHING �- SVM STANDARD VALVE MODULE FUSED 8 ROLL GROOVED DISCONNECT TR I NSTR U M ENT TRANSMITTER -J COUPLING TSH HIGH TEMP ERATU RE SWITCH F--1 III UNION J JUNCTION BOX TSP TWISTED SHIELDED PAIR L--J LINO UNLESS NOTED OTHERWISE ❑ COUPLING NPTXP --,-- -L-J SEAL -OFF VAC VOLT, ALTERNATING CURRENT Y DRAIN BYOTHEIRS VFD VARIABLE FIR EQUENCYDRIVE BUTTERFLY VALVE BY EMX VFDC VFD (SHI ELDED) CABLE WAN WI DE AREA NETWORK EXISTING ZVM ZOMBIE VALVE MODULE NAME DATE IREV DESCRIPTION DATE PROPRIETARY AND CONFIDENTIAL MATERIAL PROJECT: COMMENTS: M MENTS: ITEM REV DRAWN CPA 10/25/2023 A PRELIMINARY 10/25/2023 THE INFORMATION CONTAINED THIS VARIES . HAMPSTEAD, NC N P&IDN T • DRAWING IS THE SOLE PROPERTY OF ENVIROMIX. ANY REPRODUCTION IN PART OR QUANTITY Envl roM ix A CHECKED WWK 10/25/2023 N ENGINEER AS WHOLE WITHOUT THE WRITTEN W. KING i PERMISSION OF ENVIROMIX IS PROHIBITED. N/A BIOMIX COMPRESSED GAS MIXING SYSTEM o SCALE: 1:1 (PROJECT#: N/A c" P&ID- 1 OF 2 1 T 1 I 1 8 7 6 5 4 3 2 1 C f e A 8 1 7 1 6 1 5 + 4 1 3 1 2 1 1 v NOTE 1: PROVIDE GENERAL PIPE ROUTE/LENGTHS AND EMX CAN RECOMMEND DIAMETER, ISOLATION VALVES, ETC. ^ C EMX-REC-1 (240 GAL) }Ej__Do� CA (NOTE 1) 20 120VAC r7 COALESCING EMX-COMP-1 i v FILTER PI SEE NOTE 6►r�+. ---dV F 480VAC - - - - - - (MAX UNLOAD ' 115 PSI) } 0 .5" CA 1I 1I-< CA (NOTE 1) DC-l{ PRESSURE o< INTEGRAL DRYER � TUBING 3/8" DR TUBING IN S --- VAC 1<5 AMPS)--- Y Y Y _ AUTO -DRAIN VALVE z m 5/16" ID TUBING � 6 Y Y STATUS HORSEPOWER CAPACITY POWER SUPPLY FULL LOAD CONSTANT EQUIPMENT (NEW/FUT) QTY / WATTS (VOLTAGE/PHASE) AMPS SPEED /VFD NOTES EMX-COMP-1 NEW 1 3 HP 13 SCFM 480 / 3 5.5 CONSTANT ATLAS COPCO G2-116-AFF; DUTY; 116 PSI; HEAT REJECTION 8,399 BTU/HR PER 2.7 (DRYER) SPEED/VFD COMPRESSOR; MIN TEMP 32F; MAX TEMP 115F; REFRIG. DRYER, COALESCING FILTER; ISO 8573.1 AIR QUALITY 1.4.2. EXTERNAL TIME DELAY FUSED DISCONNECTS REQUIRED (BY B OTHERS). A COMPRESSORS & RECEIVER PRELIMINARY NAME DATE REV DESCRIPTION DATE PROPRIETARY AND CONFIDENTIAL MATERIAL DRAWN CPA I A PRELIMINARY 10/25/2023 I 10/25/2023 THE INFORMATION CONTAINED IN THIS VARIES DRAWING IS THE SOLE PROPERTY OF CHECKED WWK 10/25/2023 ENVIROMIX. ANY REPRODUCTION IN PART OR QUANTITY Envi roM ix AS WHOLE WITHOUT THE WRITTEN ENGINEER W. KING i PERMISSION OF ENVIROMIX IS PROHIBITED. N/A 8 7 1 6 5 T z 1¢ V � O 2 \ cc I0 Nl0 � I~ wl� v� IN mIZ ¢ Ia alb zl WIC Icc O 10 I EMX-ZVM-1 (2 VALVES; OUTDOORS) SLOR 120 VAC 20 AMP�- HS SFREQ DUR I I 6 5/16" CA TUBING CA TEE W/ I 1 PLUG 1 I I 1 iL 1 I — — — — — — — — — — — — — — — — — — — — — - SUPPLY PIPE, HEADER 1 1 SUPPLY PIPE, HEADER I (1/VALVE; 1/TANK) (1/VALVE; 1/TANK) I 1 1.5" HEADER 1 I 1.5" HEADER I j SUPPLY PIPE SUPPLY PIPE j 1 � NOZZLE (6; TYP) I HEADER 1 I 1 HEADER NOZZLE (4; TYP) I I I I ,JJ I 1 I 1 I I I ----J PAX-01 L--------------------------J AX9-01 (PRE -ANOXIC BASIN) (POST -ANOXIC BASIN) VALVE MODULES, MIXING HEADERS/NOZZLES COMMENTS: PROJECT: ITEM m REV N/A HAMPSTEAD, NC P&ID N N BIOMIX COMPRESSED GAS MIXING SYSTEM SCALE: 1:1 (PROJECT#: N/A 0 c" P&ID- 2 OF 2 4 1 3 1 2 1 1 C f I. A E:3 7 5 0 3 2 F E v a A BioMixTM COMPRESSED GAS MIXING SYSTEM HAMPSTEAD,, NORTH CAROLINA - ANOXIC ZONES INSTALLATION & OPERATION NOTES: 1. TO ADEQUATELY PROTECT AIR VALVES IN VALVE MODULE(S), REMOVE ALL DIRT, SAND, & DEBRIS FROM COMPRESSED AIR PIPING PRIOR TO INSTALLATION AND FOLLOWING ASSEMBLY. FLUSH WITH AIR AND/OR WATER THOROUGHLY. 2. CONTRACTOR RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS AND CLEARANCES OF INSTALLED EQUIPMENT FOR CODE COMPLIANCE AND ADHERENCE TO PROJECT SPECIFIC REQUIREMENTS PRIOR TO EQUIPMENT RELEASE. 3. FIELD MODIFICATION TO HEADER, DROP LEG, OR NOZZLE IS NOT REQUIRED OR PERMITTED. COORDINATE WITH ENVIROMIX REGARDING ANY PROPOSED DEVIATIONS FROM THESE DRAWINGS. 4. LAYOUT HEADER(S) IN ACCORDANCE WITH PLAN DIMENSIONS. FIELD LOCATE NOZZLES AND ANCHORS USING ASSEMBLED HEADER TO INSURE DROP LEGS ARE INSTALLED AS THEY LAY. DO NOT PRE -DRILL ANCHORS BASED ON FABRICATED DIMENSIONS. 5. DRILL AND INSTALL ALL THREADED ROD VERTICAL WITH EPDXY ADHESIVE (EPDXY BY OTHERS UNLESS OTHERWISE STATED). 6. ALL HEADER SUPPLY PIPES SHALL BE LEVEL OR SLOPING DOWN FROM THE VALVE MODULE TO THE HEADERS UNLESS SHOWN OTHERWISE HEREIN. 7. ROUTE ALL HEADER SUPPLY PIPES BELOW THE NORMAL MINIMUM WATER SURFACE ELEVATION WHEN POSSIBLE. 8. APPLY PIPE TAPE AND THREAD COMPOUND TO ALL THREADED PIPING CONNECTIONS. 9. DO NOT INTRODUCE CONSTRUCTION DEBRIS INTO THE COMPRESSED AIR PIPING SYSTEM. 10. IF VALVE MODULE(S) AND COMPRESSED AIR ARE NOT ONLINE AND TANK MUST BE PUT BACK INTO SERVICE, PRIOR TO FILLING TANK WITH PROCESS LIQUID, ALL HEADERS, NOZZLES, AND HEADER SUPPLY PIPING SHALL BE INSTALLED. HEADER SUPPLY PIPING SHALL BE INSTALLED TO THE ISOLATION VALVES AND THE ISOLATION VALVES SHALL BE CLOSED. HEADER SUPPLY PIPING AND HEADERS MUST BE FLUSHED WITH COMPRESSED AIR FOR ONE (1) MINUTE ONCE (1) EVERY TWO (2) WEEKS MINIMUM UNTIL THE MIXING SYSTEM IS COMMISSIONED. 11. MIXING SYSTEM SHALL BE ON (ENABLED AND MIXING) PRIOR TO FILLING WITH PROCESS LIQUID AND/OR ADDING ADDITIONAL LIQUID TO A PARTIALLY FULLY TANK AND REMAIN ON AS A NORMAL OPERATING PROCEDURE. SYSTEM SHOULD BE DISABLED FOR ONLY SHORT DURATIONS FOR ROUTINE MAINTENANCE OR WHEN TANK IS EMPTY. 12. IF OFF CYCLING IS TO OCCUR FOR MORE THAN 24 HOURS, REFER TO O&M MANUAL FOR OFF CYCLING OPERATION. 13. REFERENCE SCOPE AND P&ID FOR ENVIROMIX SCOPE OF SUPPLY. 14. COLD WEATHER STORAGE FOR INSTALLED HEADERS AND HORIZONTAL RUN HEADER SUPPLY PIPING NOT ONLINE: FILL TANK(S) WITH CLEAN WATER OR PROCESS LIQUID 3-FT MIN. ABOVE ALL HEADERS AND HORIZONTAL PIPE RUNS OF HEADER SUPPLY PIPING. BRACE ALL VERTICAL HEADER SUPPLY PIPES AT THE LIQUID SURFACE WITH STYROFOAM TO PREVENT DAMAGE FROM THE ICE. WHEN ICE FORMS AT THE SURFACE, DO NOT DRAIN UNTIL ALL ICE HAS MELTED. 15. A SPECIFIC VALVE IS ASSIGNED TO EACH HEADER AS LABELED IN PLAN VIEW. VALVE ASSIGNMENTS MAY BE CHANGED ONLY WITH EMX APPROVAL. CURRENT STA TUS NAME DATE REV DESCRIPTION BY DATE MATERIAL PROJECT # N/A PRELIMINARY PROPRIETARY AND CONFIDENTIAL DRAWN WEV 10/16/2023 A PRELIMINARY WV 10/16/2023 THE INFORMATION CONTAINED IN THIS 304L SS � BIOMIX COMPRESSED GAS MIXING DRAWING IS THE SOLE PROPERTY OF SYSTEM - ANOXIC ZONES CHECKED ENVIROMIX. ANY REPRODUCTION IN PART OR QUANTITY EnviroMIX AS A WHOLE WITHOUT THE WRITTEN N/A ENGINEER W. KING PERMISSION OF ENVIROMIX IS PROHIBITED. HAMPSTEAD, NC 8 7 6 5 4 P L U RIS COMMENTS ITEM REV MECHANICAL "' N O N 0 SHEET SCALE OFT 1FT 2FT o SHEET i i i :64 This bar measures 2" when printed full scale. P O F S 3 2 1 F I x 0 A F E v M. A 8 7 6 5 15'-0" _ 1 4'-6 311 8 PA-02 —3'-9 7'-6" - PRE -AERATION BASIN PAX-01 PRE -ANOXIC BASIN 27'-2" A i I TEE ADJACENT HEADER NO. Is TO SHARE J SINGLE HEADER SUPPLY PIPE HEADER NO.] (NH1): 2 TYP 3 NOZZLES PER HEADER PA-01 PRE -AERATION BASIN 0 1 0' -0" -5' -0"~ 0 _ U x O QQ .� Qom O n V1.5" HEADER SUPPLY PIPING SEE SHEET P5 FOR TYPICAL SUPPORT DETAILS PLAN VIEW SCALE: 1 /4" = 1'-0" NOTES: 1. EMX MIXING EQUIPMENT LOCATIONS MAY BE ADJUSTED 6" TO AVOID INTANK OBSTRUCTIONS. FOR LARGER DEVIATIONS, CONSULT EMX. 2. ALL NOZZLES ON A GIVEN HEADER (AND/OR SHARING THE SAME HEADER SUPPLY PIPE) TO BE INSTALLED LEVEL WITHIN 1 /2" ELEVATION OF EACH OTHER. SUBMIT LEVEL DOCUMENTATION TO EMX AT TIME OF STARTUP. 3. FLUSH ALL PIPING THOROUGHLY WIHT AIR OR WATER PRIOR TO INSTALLATION. 4. APPLY PIPE TAPE AND THREAD COMPOUND TO ALL THREADED PIPING CONNECTIONS. 5. DO NOT INTRODUCE CONSTRUCTION DEBRIS TO THE COMPRESSED AIR PIPING SYSTEM. 6. REFERENCE ADDITIONAL NOTES ON SHEET P1 AND THE P&ID. CURRENT STATUS PRELIMINARY NAME DATE REV DRAWN WEV 10/16/2023 , A CHECKED ENGINEER W. KING DESCRIPTION PRELIMINARY BY DATE PROPRIETARY AND CONFIDENTIAL MATERIAL WV 10/16/2023 THE INFORMATION CONTAINED IN THIS 304L SS DRAWING IS THE SOLE PROPERTY OF ENVIROMIX. ANY REPRODUCTION IN PART OR QUANTITY AS A WHOLE WITHOUT THE WRITTEN N/A PERMISSION OF ENVIROMIX IS PROHIBITED. f 3' -3" E 3 MB-02 MBR BASIN MB-01 MBR BASIN HEADER NO.2 (NH2): 1 TYP 4 NOZZLES PER HEADER PROJECT # N/A COMMENTS /��� BIOMIX COMPRESSED GAS MIXING EnviroM*ix SYSTEM -ANOXIC ZONES �� HAMPSTEAD, NC 2 ITEM MECHANICAL SHEET SCALE 1:48 A OFT 1 FT 2FT I I I This bar measures 2" when printed full scale. 1 REV Co N O N 0 o SHEET P2OF5 F I 0 A 7 I 5 0 3 11 E:3 7 5 0 8. /-EMX-ZVM-1 3 2 F E A CURRENT STATUS PRELIMINARY DRAWN CHECKED ENGINEER � PAX-01 j PRE -ANOXIC jBASIN 17'-0" SWD HEADER NO.I (2 TYP)_/ 1.5" HEADER SUPPLY PIPING i YLLIj AX9-Ol POST-ANOXICIN j LSEE SHEET P4 FOR NOZZLE INSTALLATION DETAILS SECTION A -A SCALE: 1 /4'• = 1' 0" EMX-ZVM-1 A IU SECTION B-B SCALE: 1 /4" = 1'-0" NAME DATE REV DESCRIPTION BY DATE WEV 10/16/2023 A PRELIMINARY WV 10/16/2023 W. KING PA-01 PRE -AERATION BASIN SEE SHEET P4 FOR HEADER/NOZZLE INSTALLATION DETAILS PROPRIETARY AND CONFIDENTIAL MATERIAL THE INFORMATION CONTAINED IN THIS 304L SS DRAWING IS THE SOLE PROPERTY OF ENVIROMIX. ANY REPRODUCTION IN PART OR QUANTITY AS A WHOLE WITHOUT THE WRITTEN NSA PERMISSION OF ENVIROMIX IS PROHIBITED. ' -0" 18 SW D HEADER NO.2 (1 TYP) EMX-ZVM-1 THROTTLING VALVE ASSEMBLY WITH INSULATION-\ 1.5" RG COUPLING 1.5" X 3" RG X MNPT PIPE NIPPLE 1.5" FNPT BALL VALVE 1.5" X 3" MNPT X MNPT PIPE NIPPLE 1.5" FNPT FLUSHING TEE WITH MNPT PLUG (END OF EMX SCOPE) EnviroMIX T�T , 0 0 0 0 0 0 _b 1.5" HEADER SUPPLY PIPING (NOT SHOWN) :J MB-01 MBR BASIN 1.5" RG COUPLING 1.5" RG X MNPT PIPE NIPPLE (ALTERNATE WITH 3" AND 911) 1.5" FNPT BALL VALVE 1.5" MNPT X P ADAPTER TOP MOUNT PANEL STANCHION SUPPORT WITH VM STANDOFF BRACKET (BY EMX) (6) 1 /2 ANCHORS TYP WITH 6 EMBEDMENT (BY OTHERS) T T 0 0 0 0 0 DETAIL A SCALE: 1-1/2" = 1'-0" PROJECT # N/A COMMENTS BIOMIX COMPRESSED GAS MIXING SYSTEM - ANOXIC ZONES HAMPSTEAD, NC 4 ITEM MECHANICAL SHEET SCALE 1:32 OFT 1 FT 2FT I I 1 This bar measures 2" when printed full scale. 1 REV Co N 0 N 0 No SHEET P3OF5 F 0 A 8 7 C� 5 3 E:3 7 5 4 3 2 1 F E M. A MWEdMERIEd J OFFSET DROP LEG INSTALLATION DETAIL (4) ANCHOR SETS AND HARDWARE REQUIRED PER NOZZLE ING 1.5" SCH 10 HEADER SHORT )P LEG NOZZLE TOP VIEW DETAIL CURRENT STA TUS NAME DATE PROPRIETARY AND CONFIDENTIAL REV DESCRIPTION BY DATE PRELIMINARY DRAWN WEV 10/16/2023 A PRELIMINARY WV 10/16/2023 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CHECKED ENVIROMIX. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN ENGINEER W. KING PERMISSION OF ENVIROMIX IS PROHIBITED. 8 7 6 NOTES: 1. ALL NOZZLES ON A GIVEN HEADER TO BE INSTALLED LEVEL WITHIN 1/2-INCH ELEVATION OF EACH OTHER. SUBMIT LEVEL DOCUMENTATION TO ENVIROMIX AT STARTUP. 2. FLUSH ALL HEADER SUPPLY PIPES AND HEADERS THOROUGHLY WITH AIR OR WATER PRIOR TO ASSEMBLY. 3. FLUSH ALL COMPRESSED AIR PIPING BETWEEN COMPRESSOR AND VCP THOROUGHLY WITH AIR FOLLOWING INSTALLATION. 4. APPLY PIPE TAPE AND THREAD COMPOUND TO ALL THREADED PIPING CONNECTIONS. 5. DO NOT INTRODUCE CONSTRUCTION DEBRIS SUCH AS PIPE TAPE INTO THE COMPRESSED AIR PIPING SYSTEM. 6. INSTALLATION OF OFFSET STYLE DROP LEGS WILL BE THE SAME AS SHOWN FOR STRAIGHT DROP LEGS. 7. ALL HARDWARE TO BE 316SS UNLESS OTHERWISE NOTED. 8. EPDXY ADHESIVE PROVIDED BY OTHERS. MATERIAL 304L SS QUANTITY N/A 5 FLAT FLOOR INSTALLATION: (4) ANCHORS REQUIRED PER NOZZLE WITH 3" EMBEDMENT AND EPDXY ADHESIVE. BOTTOM OF NOZZLE TO BE 1-2" ABOVE TANK FLOOR. SLOPED FLOOR INSTALLATION: (4) ANCHORS REQUIRED PER NOZZLE WITH 3" EMBEDMENT AND EPDXY ADHESIVE. INSTALL SHALLOWEST NOZZLE FLUSH WITH FLOOR. ALL NOZZLES ON A GIVEN HEADER AND/OR SHARING SAME HSP TO BE INSTALLED WITHIN 1 /2" ELEVATION OF EACH OTHER. EPDXY ADHESIVE BY OTHERS. 1 "-2" TY P v SLOPED FLOOR NOZZLE SECTION SCALE 1:8 PROJECT # N/A COMMENTS /��� BIOMIX COMPRESSED GAS MIXING EnviroM*ix SYSTEM -ANOXIC ZONES �� HAMPSTEAD, NC 0 3 3/8" THREADED ROD (TRIMMED TO V EXPOSED THREADS AFTER INSTALLATION) HEX NUT 8" LOCK WASHER 3/8" FLAT WASHER 3/8" FLAT WASHER 3/8" HEX NUT *DO NOT GROUT FILL ITEM NOZZLE INSTALLATION SHEET SCALE OFT 1FT 2FT 1:8 This bar measures 2" when printed full scale. 2 1 REV Co N O N 0 No SHEET P4OF5 F P. 0 A E D 8 7 HEADER AND HEADER SUPPLY PIPING SUPPORT FLOOR MOUNT LESS THAN 24" ABOVE FLOOR 1 HSP 1 /2" HEX NUT 1 /2" LOCK WASHER 1 /2" SQUARE WASHER 1 /2" FLAT WASHER 1 /2" HEX NUT 3" EMBEDMENT AND c EPDXY ADHESIVE (EPDXY BY OTHERS)_j 1.5" PIPE SIZE (1.5" HSP OR HEADER) 1/2" THREADED ROD VERTICAL PIPE SUPPORT GREATER THAN 24" ABOVE FLOOR 1 HSP SLOTTED STRUT CUT TO LENGTH IN FIELD 1 /2" X 5" THREADED ROD B 1 /2" FLAT WASHER (X2) 1 /2" LOCK WASHER 1 /2" HEX NUT (4 REQ. PER POST BASE WITH 3" EMBEDMENT AND EPDXY ADHESIVE) A 1.5" PIPE SIZE CUSH CLAMP (1.5" SCH 10 HSP) OR 2.0" PIPE SIZE CUSH CLAMP(2.0 HSP) COST BASE 1 /2" X 3" HEX HEAD BOLT 1 /2" WASHER X2 1 /2" HEX NUT (2 PER POST BASE) CURRENT STA TUS NAME DATE REV DESCRIPTION PRELIMINARY DRAWN WEV 10/16/2023 '4 PRELIMINARY CHECKED ENGINEER W. KING 8 7 6 5 4 3 3 HORIZONTAL RUN PIPE SUPPORT GREATER THAN 24" ABOVE FLOOR 2 HSPs 1.5" PIPE c17F CUSH CL, (1.5" SLOTTED STRUT CUT TC LENGTH IN FIELD SLOTTED STRUT CUT TO LENGTH IN FIELD 4 HOLE ANGLE BRACKET 1 /2" X 1-1 /2" HEX BOLT 1 /2" FLAT WASHER 1 /2" HEX NUT (4 PER BRACKET) SEE VERTICAL PIPE SUPPORT DETAIL FOR POST .% BASE HARDWARE HORIZONTAL PIPING SUPPORT (H-SUPPORT) FLOOR MOUNT LARGER THAN 24" ABOVE FLOOR -OR- MORE THAN 2 HSPs (AT ANY HEIGHT) 1.5" PIPE SIZE CUSH CLAMP FSLOTTED STRUT CUT TO (1.5" HSP) LENGTH IN FIELD 4 HOLE ANGLE BRACKET 1 /2" X 1-1 /2" HEX BOLT 1 /2" FLAT WASHER 1 /2" HEX NUT (4 PER BRACKET) OLL VERTICAL PIPE SUPPORT DETAIL FOR POST BASE HARDWARE SLOTTED STRUT CUT TO LENGTH IN FIELD BY DATE MATERIAL PROPRIETARY AND CONFIDENTIAL WV 10/16/2023 THE INFORMATION CONTAINED IN THIS 304L SS DRAWING IS THE SOLE PROPERTY OF ENVIROMIX. ANY REPRODUCTION IN PART OR QUANTITY AS A WHOLE WITHOUT THE WRITTEN NSA PERMISSION OF ENVIROMIX IS PROHIBITED. 6 5 EnviroMIX 5 WALL SUPPORTS 1.5" PIPE CUSH CLAMP (1.5" HSP) OR 2.0" PIPE CUSH CLAMP (2.0" HSP) 1-5/8" U N ISTRUT PIPE CLAMF 2 1 PIPE 3.75" OR ~6.25in"~ TYP STRUT 6 PIPES 2 7„ - 8 3/8" X 3-3/4" WEDGE ANCHOR INSTALL MIN. OF (2) ANCHORS AT MAX. OF 12" O.C. WITH 2" EMBEDMENT. 3/8" x 3-3/4" WEDGE ANCHORS PROVIDED a a �v ° a a ° a a a. ° ° o °a ° ° ° a 6 ° i ° a ° ' ° o ° ° PIPE SUPPORT / _JRVED WALL MOUNTING DETAIL MECHANICALLY JOINED PRESS PIPE AND FITTINGS NOTES: 1. SUGGESTED PIPE SUPPORTS SHOWN. ACTUAL PIPE SUPPORTS MAY VARY IN LENGTH, CLAMP QTY, AND SPACING. 2. PIPE SUPPORTS TYPICALLY PLACED 10' MAX O.C. BUT NOT WITHIN 3' OF AN UNSUBMERGED BEND EXPOSED TO AMBIENT TEMPERATURE. 3. ALL HARDWARE TYPICAL PER SUPPORT. ALL HARDWARE PROVIDED 316SS UNLESS OTHER WISE STATED. 4. STRUT PROVIDED IN 10' LENGTHS AND CUT TO LENGTH IN THE FIELD. 5. EPDXY ADHESIVE TYPICAL OF ALL THREADED ROD ANCHORS AND WILL BE PROVIDED BY OTHERS. PROJECT # N/A COMMENTS BIOMIX COMPRESSED GAS MIXING SYSTEM - ANOXIC ZONES HAMPSTEAD, NC 4 3 2 QTY OF CLAMPS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ITEM PIPE SUPPORTS SHEET SCALE NTS LENGTH OF STRUT ± 3.75" SPACING 0'-6'' 0' — 1 0" 2'-6'' 2'-10'' 3-2'' 3-6'' 3-10" 4-2'' 4-6'' 4'-10'' OFT 1 FT 2FT I I I This bar measures 2" when printed full scale. 1 LENGTH OF STRUT ± 6.25" SPACING 0'-6'' 0' -12" 1 '-6'' 2'-0'' 3-6'' 4-0'' 4-6'' 5'-0'' 6-0'' 6-6'' 7-0'' REV Co N O N No SHEET P5OF5 F e A N C Ul r 7 0 9 m of 8 1 7 1 6 1 11 HAMPSTEAD) A %'4 D D D:RAW vG _ ST 3 HNC-1-01 COVER SHEET HNC-1-02 SYMBOLS &LEGEND 1 HNC-I-03 SYMBOLS &LEGEND 2 HNC-I-04 EQUALIZATION BASIN HNC-I-05 FINE SCREENS HNC-I-06 PRE -ANOXIC BASIN 01 HNC-I-07 PRE -AERATION BASIN 01 HNC-I-08 PRE -AERATION BASIN 02 HNC-I-09 FEED FORWARD /INTERNAL RECYCLE PUMPS HNC-I-10 POST -ANOXIC BASIN 01 HNC-I-11 MEMBRANE BIOREACTOR BASIN 01 HNC-I-12 MEMBRANE BIOREACTOR BASIN 02 HNC-I-13 MBR PERMEATE PUMPS HNC-I-14 WASTE ACTIVATED SLUDGE PUMPS HNC-I-15 MEMBRANE BASIN AND PROCESS AIR BLOWERS HNC-I-16 CLEAN -IN -PLACE HNC-I-17 CHEMICAL (ALUM & NaOH) INJECTION HNC-I-18 CHEMICAL (CARBON & PERACTIC ACID) INJECTION HNC-I-19 WASHWATER LIFT STATION FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/4/24 MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 9 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 r REVISIONS DRAWN DATE H A M P S T E A D W W T P EXPANSION REV DESCRIPTION DATE APPROVED HAMPSTEAD NC CHECKED DATE � COVER SHEET APPROVED DATE SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-01 C APPROVED DATE SCALE SHEET NO. N/A 1 -of-19 4 I 3 I 2 I 1 11 C 0 It C M"q MILA l 8 I 7 INSTRUMENT SYMBOL LABELS ONTROL (;�LOCATION INSTRUMENT & FUNCTION SYMBOLS FIELD FRONT MAIN FRONT AUX REAR MAIN ACCESSIBLE ACCESSIBLE ACCESSIBLE INACCESSIBLE DISCRETE ID CON INSTRUMENT LOOP LOC C) SHARED DISPLAY rlD TOP SHARED CONTROL LOOP BTM I CSC COMPUTER FUNCTION Loop Loc TOP PROGRAMMABLE ID _ LOGIC CONTROL Oo BTM I CX: ANALOG INPUT ANALOG OUTPUT DISCRETE INPUT DISCRETE OUTPUT MBR PLC INPUT/OUTPUT - � - � 0 0 B D E F G H I J K L M N 0 P Q R S T U V W Y 1i no C9i CONTROL ABBREVIATIONS 1/2 SELECT 1 OR 2 POSITION A/M REMOTE -MANUAL SETTING AMSS REMOTE -MANUAL -START -STOP FUNCTION DO DISSOLVED OXYGEN ESTOP EMERGENCY STOP FAIL FAILURE CONDITION HOR HAND -OFF -REMOTE 1/1 CURRENT TO CURRENT CONVERTER UP CURRENT TO PNEUMATIC CONVERTER LEL LOWER EXPLOSIVE LIMIT LOR LOCAL -OFF -REMOTE LOS LOCK -OUT -STOP LR LOCAL -REMOTE OC OPEN -CLOSE OCR OPEN -CLOSE -REMOTE OIL LUBRICATING OR COOLING OIL ON ON CONDITION OPEN OPEN CONDITION OR COMMAND OSC OPEN -STOP -CLOSE RDY READY CONDITION RESET RESET FAILURE RUN MAINTAINED RUN COMMAND SP SET POINT SS START -STOP WND MOTOR WINDING BCN BEACON V/P VOLTAGE TO PNEUMATIC CONVERTER V/1 VOLTAGE TO CURRENT CONVERTER O INSTRUMENT SYMBOL LABEL IDENTIFICATION FIRST LETTER SUCCEEDING LETTERS MEASURED OR READOUT OR INITIATING VARIABLE MODIFIER PASSIVE OUTPUT FUNCTION FUNCTION ANALYSIS ALARM BURNER,COMBUSTION USER'S CHOICE USER'S CHOICE USER'S CHOICE CONTROL DENSITY DIFFERENTIAL VOLTAGE SENSOR(PRIMARY ELEMENT) FLOW RATE RATIO(FRACTION) USER'S CHOICE GLASS,VIEWIG DEVIDE HAND CURRENT(ELECTRICAL) INDICATE POWER SCAN TIME,TIME SCHEDULE TIME RATE OF CHANGE CONTROL STATION LEVEL LIGHT MOISTURE MOMENTARY USER'S CHOICE USER'S CHOICE USER'S CHOICE USER'S CHOICE ORIFICE, RESTRICTION PRESSURE,VACUUM POINT(TEST) CONNECTION QUANTITY INTEGRATE,TOTALIZE RADIATION RECORD SPEED,FREQUENCY SAFETY SWITCH TEMPERATURE TRANSMIT MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION VIBRATION,MECANICAL ANALYSIS VALVE,DAMPER,OR LOUVER WEIGHT,FORCE WELL UNCLASSIFIED X AXIS UNCLASSIFIED UNCLASSIFIED EVENT,STATE,PRESENCE Y AXIS RELAY, COMPUTE, CONVERT DRIVER,ACTUATOR, POSITION, DIMENSION Z AXIS UNCLASSIFIED,FINAL CONTROL ELEMENT 7 L MODIFIER USER'S CHOICE HIGH LOW MIDDLE, INTERMEDIATE USER'S CHOICE MULTIFUNCTION GENERAL ABBREVIATIONS AFD ADJUSTABLE FREQUENCY DRIVE AS AIR SUPPLY AXP POST ANOXIC BFV BUTTERFLY VALVE BV BALL VALVE CMPTR COMPUTER CS CONSTANT SPEED CTA CITRIC ACID CV CHECK VALVE DO DISSOLVED OXYGEN DR DRAIN DV DIAPHRAGM VALVE ES ELECTRICAL SUPPLY FC FAIL CLOSED FO FAIL OPEN FP FIELD PANEL GAL GALLONS GBV GLOBAL VALVE GND GROUND GV GATE VALVE HI HIGH HMI HUMAN -MACHINE INTERFACE 1/0 INPUT/OUTPUT INST INSTRUMENT KGV KNIFE GATE VALVE LCP LOCAL CONTROL PANEL MB MBR BASIN MBR MEMBRANE BIOREACTOR MCC MOTOR CONTROL CENTER MUX TELEMETRY MULTIPLEXING NC NORMALLY CLOSED NO NORMALLY OPEN NV NEEDLE VALVE OF OVERFLOW PA PRE -AERATION PAX PRE -ANOXIC MBR PLC PROGRAMMABLE LOGIC CONTROLLER PRV PRESSURE RELIEF VALVE PT PRESSURE TAG PV PLUG VALVE PW PLANT WATER REQD REQUIRED RLS RELEASE RM ROTOMETER SB SPUTTER BOX MBR OIT SUPERVISORY CONTROL AND DATA ACQUISITION SH SLUDGE HOLDING SMU SUBMERGED MEMBRANE UNIT SP SUMP PUMP SWD SIDE WATER DEPTH TEMP TEMPERATURE TMP TRANS MEMBRANE PRESSURE TURB TURBIDITY TV TELESCOPING VALVE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UPS UNINTERRUTABLE POWER SUPPLY V VENT VFD VARIABLE FREQUENCY DRIVE UV ULTRA VIOLET VS VARIABLE SPEED FLOW STREAM ABBREVIATIONS UNCLASSIFIED CAS CAUSTIC SODA CIP CLEAN IN PLACE CTA CITRIC ACID FF FEED FORWARD INF INFLUENT IR INTERNAL RECYCLE MCRC MICRO-C NaOH SODIUM HYDROXIDE PA PROCESS AIIR PRIM PERMEATE PW PLANT WATER RAS REACTIVATED SLUDGE SCA SCOUR AIR SHC SODIUM HYPOCHLORITE WAS WASTE ACTIVATED SLUDGE FINAL PLAN - NOT RELEASED FOR CONSTRUCTION 6/4/24 MICHAEL C. GALLANT, PE, PA PO BOX 4039 SURF CITY, NC 28445 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 t 4 1 3 PROCESS ZONES ZONE # PROCESS DESCRIPTION 01 WAS PUMPS 02 HEADWORKS 03 EQUALIZATION 04 DE-OX 05 ANAEROBIC 06 PRE -ANOXIC 07 SWING BASIN 08 PRE -AERATION 09 POST ANOXIC 10 MEMBRANE BIOREACTOR 11 REACTIVATED SLUDGE 12 INTERNAL RECYCLE 13 PERMEATE COLLECTION 14 SCOUR AIR 15 PROCESS AIR 16 CLEAN IN PLACE 17 WASTE ACTIVATED SLUDGE 18 ULTRAVIOLET FILTRATION 19 CHEMICAL ADDITION 20 USER CHOICE 02 99 MBR PLC / MBR OIT EQUIPMENT LABELS EQUIPMENT NUMBER EQUIPMENT NAME SPEC 01 SPEC 02 SPEC 03 SPEC 04 X-01-01 EQUIPMENT PROCESS INSTANCE NAME ZONE NUMBER ABBREVIATION NUMBER PIPE LINE NUMBER IDENTIFIER X-MTL-FSA-000 X = PIPE SIZE MTL = PIPE MATERIAL FSA = FLOW STREAM ABBREVIATION 000 = INSTANCE NUMBER VALVE NUMBER IDENTIFIER x VA-PZ-000 X = VALVE SIZE VA = VALVE TYPE ABBREVIATION PZ = PROCESS ZONE 000 = INSTANCE NUMBER SHEET CONNECTION SYMBOLS FLOW STREAM PROCESS CONNECTION ORIGIN/DESTINATIO IN THIS CONTRACT SHT XX. X = INSTANCE NUMBER FLOW STREAM \ PROCESS CONNECTION ORIGIN/DESTINATIO NOT IN THIS CONTRACT FLOW STREAM PROCESS CONNECTION ORIGIN/DESTINATION NOT IN THIS CONTRACT ORIGIN/DESTINATIO OPTIONAL LINE SYMBOLS MAIN PROCESS FLOW MAIN PROCESS FLOW (EXISTING) SECONDARY PROCESS FLOW SECONDARY (EXISTING) NON PROCESS FLOW PNEUMATIC INSTRUMENT AIR ANALOG ELECTRIC SIGNAL DISCRETE ELECTRIC SIGNAL CAPILLARY TUBE SONIC SIGNAL (UNGUIDED) SOFTWARE OR DATA LINK MECHANICAL LINK HYDRAULIC 120V>— POWER SUPPLY SA>- SERVICE AIR AUPPLY FLOW PRIMARY ELEMENT SYMBOLS I ORIFICE PLATE SINGLE PORT PITOT TUBE OR PITOT-VENTURI TUBE AVERAGING PITOT TUBE THERMAL MASS FLOWMETER M MAGNETIC FLOWMETER TURBINE OR PROPELLER -TYPE PRIMARY ELEMENT �— ROTOMETER POSITIVE DISPLACEMENT TYPE FLOW TOTALIZING INDICATOR C VORTEX SENSOR TARGET TYPE SENSOR �--i VENTURI TUBE C SONIC FLOWMETER o DENSITY METER REVISIONS DRAWN DATE REV DESCRIPTION DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 4 3 2 22 1 HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC SYMBOLS & LEGEND SIZE CONTRACT NO. DRAWING NO. REV. D — HNC-1-02 C SCALE SHEET NO. N/A 2—of-19 1 C 0 0 8 I 7 I 6 I 5 VALVE SYMBOLS NORMALLY NORMALLY 3-WAY OPEN CLOSED _ SUBMERSIBLE PUMP INLET FILTER D Da ►/ ICJ GATE VALVE Db ►N CnJ GLOBAL VALVE _ SUBMERSIBLE PUMP WITH X. X. X. GUIDE RAIL INLET SILENCER 1 FILTER COS I� BALL VALVE BV-XX BV-XX BAY- X X. X. CQ m PLUG VALVE Pv-XX Pv-XX DRY SUMP PUMP AIR COMPRESSOR I ICI BUTTERFLY VALVE B F-XX ® DIAPHRAGM VALVE CENTRIFUGAL PUMP ® 55 GALLON DRUM x �J ICJ CHECK VALVE cv-xx Di< NEEDLE VALVE T v-xx METERING PUMP Ikl SILENCER KNIFE GATE VALVE a 4 PRESSURE RELIEF VALVE C7 C ' � ' ROTARY LOBE PUMP CHEMICAL STORAGE TANK PS PRESSURE SWITCH PG PRESSURE REDUCING DIAPHRAGM PUMPloi ROTARY SIEVE DRUM SCREEN REGULATING VALVE. SELF-CONTAINED BACK PRESSURE REGULATING VALVE. SELF-CONTAINED10 PARISTALTIC PUMP ROTARY DRUM SCREEN � U U 1 El MECHANICAL EQUIPMENT & PIPING SYMBOLS WEIR FLEXIBLE HOSE SLIDE GATE TANK VENT WALL MOUNT MIXER YDR DRAIN MIXER III PIPE UNION TELESCOPING VALVE I I FLANGE ELECTRIC MOTOR ___� I BLIND FLANGE SAFETY SHOWER D REDUCER ID ROLLER BIN ICI Y-STRAINER X. POSITIVE DISPLACEMENT PUMP WASHER CONVEYOR -E HOSE CONNECTION �S T T ®� n� PROGRESSIVE CAVITY PUMP - SMU SINGLE WITH CA ® RUPTURE DISK VALVE OPERATOR SYMBOLS B T DIAPHRAGM, SPRING ' z-S AIR LIFT PUMP SMU SINGLE 2 MNFD © DIAPHRAGM SEAL DIAPHRAGM, PRESSURE BALANCED� ►_. z- T HANDWHEEL CENTRIFUGAL BLOWER SMU DOUBLE WITH CA HYDROPNEUMATIC TANK HT MOTOR - CYLINDER -s ROTARY BLOWER SMU SINGLE WITHOUT CA� I SOLENOID ►_. z- ROTARY SCREW BLOWER SMU DOUBLE WITHOUT CA E:� INJECTOR E3 8 I 7 6 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION Pp��N,CAR'b,O MICHAEL C. GALLANT, PE, PA PO BOX 4039 ;Q S L �� SURF CITY, NC 28445 102 72 910-448-1046 ,qF*'C"�,gallantmc@yahoo.com � NC FIRM#: C-1989 6/4/24 PIPE CAP OR PLUG PIPE WELD CAP PIPE EXPANSION JOINT REV NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 5 t 4 3 FLOW DIRECTION ARROW LINE CROSS PRIMARY PROCESS LINE CROSS SECONDARY PROCESS BY OTHERMU SCOPE OR SPEC BREAK REVISIONS DRAWN DATE DESCRIPTION DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 711 C 0 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC SYMBOLS & LEGEND SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-03 C SCALE SHEET NO. N/A 3-of-19 D MBR OIT C C E3 8 I 7 MBR PLC — — — — — — — — — MCC INFLUENT 12"-PVC-INF-001 FROMj ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 6 I 5 j Y HIGH LEVEL LOW LEVEL LEVEL LAH LAL LI 030101 030101 030101 LT 030101 LSH (LSL LE 030101 030101 030101 ❑K 4 1 3 TYP. 2 I I MOIST HIGH TEMP FAIL MHA THA YA 101 030101 11� RUN RUNNING REMOTE FLOW YC YI YI FICQ 030101 030101 030101 030101 (VFD HS I 030101 030101 HOR I I I030101 I ('FE 030101 ❑K 4" x 6" 6" I — _co > > m m dTYHM SHMXR > r SH MSHXco 030101 030101 030101 U 03300110 03300110 030102 U T T C ) C ) I I I I EQ-01 P-03-01 P-03-02 EQUALIZATION BASIN EQUALIZATION PUMP 01 EQUALIZATION PUMP 02 250,000 GAL (DUTY) (STANDBY) SWD 9'-10" 000 GPM 000 GPM FINAL PLAN - NOT RELEASED FOR CONSTRUCTION Pp."N,CA",", MICHAEL C. GALLANT, PE, PA PO BOX 4039 ;Q S L �� SURF CITY, NC 28445 1.0 72 910-448-1046 '....�P°`` gallantmc@yahoo.com "'lilit", NC FIRM#: C-1989 6/4/24 REV NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 REVISIONS DRAWN DATE DESCRIPTION DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 D MBR OIT MBR PLC MCC INFLUENT C 6"-PVC-INF-001 B2 �TO FINE SCREENS SHT 5. C 0 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC EQUALIZATION BASIN SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-04 C SCALE SHEET NO. N/A 4-of-19 1 A, I B LW311PI A ff ff E OIT 8 � 6 � 5 � — HIGH N EV _ — — EL OVERLOAD 0000 2yQ FAIL o00 HIGH LEVEL _ RUN 0OVERL1OAp� FAILp00 C 0p00 I 0A gREMOE 0YI RUNNING Zo, onn OVERLOp — — — 0000 RU A 1 _ N 0 oo00 C RUNNING — C I c _ I 000RE 0 2y:/ MOTE _ I 0000 M RUNNING 000 YI RE �� MOTE YI I 000p _ — I I - __ 00 - I MBR OIT HHSS WAS :0 — I I � q �0o HORFROM WAS PUMPS �(:O:o ,S SHT 743„PVCC HOR-Wgs_PR 0�ozo, � ESTOPM-001 pHS HOR —o- ) — _RPINFLUENT °C OEQ °JC HT-01 E 6"PHS P C INF001 INFLUENT S - _ © LOCAL _ LOCAL CONTROL PANEL ENING K — — HS — MC 1 2" X 0000 � 1" TR 6"X 10 BV_101 ll S 1„ DOCAL ' j ANSI TION TO DIP A7- ENLAR 1 ° C ❑ NNECT J GER GV_1o1 © SV-101 SPRAY MOT LSH W © © 12 CPM © 60 PSCTION 00p0 N z o U ONNECTION NLS SHT ,n R" _ :}i:ii:�: jai C I 0 PROVIDED DY KUBOTA 0 PROVjpE p BY 0 THERS/CONTRACTOR 8 MEYERS- V2 1 � DUTY SCREEN GRINDERP L U � 1 SATION SHELF Sp © N _ 6 I I S1,. SPRAY SV-201 12 GPME � 6-NPSCTION © I I I I S 1" -SCRAY FINAL PLAN © S C °1 12 NOT R ❑ u CONSTRUCjoSED FoR C. GALLANT PE PA 28445 IN 00 0 am or >9 NC pcR. C 9 Al REV SI DES - REdISIONS I NFLU Ep TySCREEN IGPM L---� CONNECT101V MOT 0000 n INF ' LUENT SCREEN (ST ANDBy) GPM I r CP— 01 SCREENINGS COMP _ R /C-IIVFT-001 © A l INFLUENT SH6.6. ►�,ly�STEA p W HAMANT P EX P PSTEADY ANs1ON FINE SCR NC 7EC dNTRACT N� E�AI 0 i e 8 I 7 1 6 I 5 4 I 3 I 1 HIGH LEVEL LOW LEVEL AL D 060101 060101 D MBR OIT MBR OIT MBR PLC MBR PLC MCC— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I— — — — — — — — — — — — — — MCC N PROCESS AIR \ FROM PACKAGE / COMPRESSOR B INFLUENT Al FROM FINE SCREEN�� 16"-PVC-INFT-001 j �FlINTERNAL SHT 5. RECYCLE FROM FF/IR PUMPS 6"-PVC-IR-001 SHT 9. �GllINTERNAL RECYCLE FROM FF/IR PUMPS 6"-PVC-IR-002 SHT 9. ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 (LSH (LSL ll 06 -- ❑K ❑K 0 CB-06-01 ENVIROMIX COURSE BUBBLE DIFFUSER O O O O O O O O O O O O O O O O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 PAX - 01 PRE -ANOXIC BASIN 54,893 GAL SWD 18'-0" FINAL PLAN - NOT RELEASED FOR CONSTRUCTION """ MICHAEL C. GALLANT, PE, PA FE sPO BOX 4039 .� S L �� SURF CITY, NC 28445 ` l02 72 910-448-1046 C, •`` gallantmc@yahoo.com NC FIRM#: C-1989 6/4/24 I:a2L9 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 REVISIONS DRAWN DATE DESCRIPTION DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE I 3 I 2 C B 1 RAS \ B �TO PA-01 I D SHT 7. RAS \ c 1 TO PA-02 I SHT 8. A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC PRE -ANOXIC BASIN SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-06 C SCALE SHEET NO. N/A 6-of-19 I 1 8 1 7 1 6 TEMP AI DO H AI AI HIGH LEVEL � LOW LEVEL AL LEVEL LI D 080101 080101 080101 080101 080101 080101 MBR OIT MBR PLC — — — — — — — — — MCC C PROCESS V1 FROM PA BLIOWERS 8"-304SS-PA-001 1 J SHT 14. M"q MILI B B ,l RAS FROM PAX-01 SHT 6. Z1 FROM TANK-001 SHT. 17 )—(1/2"-TUBE-ALUM-001 1 ALKALINITY A2 FROM TA K-002 1/2"-TUBE-NaOH-001 1 % SHT. 17 AS N 1 FROM M B-01 10"-D I-RAS-001 j SHT 11. V ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 01 — — — — — — — — — — m Poo- ry w O co AIT LIT 080101 080101 AE DO AE PH (LSH (LSL rLE 08�.101 08�.101 08�.101 08�.101 08�. ❑K ❑K ❑K ❑K 1 FB-08-01 V FINE BUBBLE DIFFUSER ❑K PA-01 PRE -AERATION BASIN 01 63,303 GAL SWD 15'-6" FINAL PLAN - NOT RELEASED FOR CONSTRUCTION MICHAEL C. GALLANT, PE, PA 16* PO BOX 4039 S L �� SURF CITY, NC 28445 02 72 910-448-1046 • IN • ��?.`` gallantmc@yahoo.com NC FIRM#: C-1989 6/4/24 Il REV NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 REVISIONS DESCRIPTION 3 10 DRAWN DATE DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 D MBR OIT MBR PLC MCC � RAS 10"-PVC-FF/IR-001 D 1 TO FF/IR PUMPS SHT 9. C 0 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC PRE -AERATION BASIN 01 SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-07 C SCALE SHEET NO. N/A 7-of-19 1 D MBR OIT MBR PLC — — — — — MCC C PROCESS AIR W 1 FROM PA BLOWERS 8"-304SS-PA-002 ) SHT 14. B l RAS FROM PAX-01 SHT 6. Z2 ALUM >-( 1/2"-TUBE-ALUM-002� FROM TANK-001 SHT. 17 ALKALINITY (1/2"-TUBE-NaOH-002� A3 FROM TANK-002 SHT. 17 R 1 RAS FROM MB-02 10"-DI-RAS-002 � SHT 12. 0 K❑ PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 7 A 5 11 0 TEMP DO pH HIGH LEVEL LOW LEVEL LEVEL AI AI Al A AL LI 080201 080201 080201 080201 080201 080201 — — — — — — — — — — — — — — — — — — — — — — — — — _—t (AIT LIT 080201 080201 AE DO AE PH (LSH (LSL rLE 080201 080201 080201 080201 080201 ❑K ❑K ❑K ❑K G TF FB-08-02 FINE BUBBLE DIFFUSER ❑K PA-02 PRE —AERATION BASIN 02 63,303 GAL SWD 15'-6" FINAL PLAN - NOT RELEASED FOR +` CONSTRUCTION REVISIONS p�•``N'CAR���p,� MICHAEL C. GALLANT, PE, PA REV DESCRIPTION �y�• PO BOX 4039 rig.,m S LSURF CITY, NC 28445 b2 72 910-448-1046gallantmc@yahoo.com NC FIRM#: C-19896/11/24 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 I 3 ow DRAWN DATE DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE D MBR OIT MBR PLC MCC 10"-PVC-FF/IR-002 �-- Ell RAS �TO FF/IR PUMPS SHT 9. 19 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC PRE -AERATION BASIN 02 SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-08 C SCALE SHEET NO. N/A 8-of-19 8 7 6 5 4 3 1 1 1 TYP. 4 TYP. 4 TYP. 4 A I I I I MOIST HIGH TEMP FAIL MA TAH YA FAIL L11�0101 110 101 110 101 YA FLOW 120101 RUN RUNNING REMOTE FICA POSITION CLOSE YC YI YI 110101 ZC ZIC D 110101 110101 110101 120101 120101 D MBR OIT MBR OIT MBR PLC MBR PLC VFD HS I , 110101 110101 HOR MCC MCC ('FIT ZSC PG 120102 120101 FCV rTSYHMSHYMOT 110102 C rFE 120101 C 110102 110102 110102 ❑ 120102 ❑K K M 10" 10" 6" INTERNAL RECYCLE 10" I S 6"-PVC-IR-001 F1 CV-1 PV-1106 PV-1109 TO PAX-01 At 10" x 6" 6„ SHT 6. PV-111102 �� © © K © P-11-02 FF/IR PUMP 02 rFl�) ZSC (STANDBY) 110101 191 110101 110 01 rFE L FCV TSH MSH MOT 110101 © 110101 11�� 11�� 110101 M 10" 10" ,r 6" \ I FEED FORWARD RAS 10" CV- 01 PV-11V05 i PV-1110 \ 6"-PVC-FF-001 J� H 1 TO AXP-01 D 1 10"-PVC-FF/IR-001 / ` � S 10 x 6 6 I SHT 10. FROM PA-01 PV-1101 © © 1 SHT 7. P-11-01 FF/IR PUMP 01 zsc (DUTY) I I� PG 120201 120201 B L 4>)FcV B TSH MSH MOT 110202 C FE 120201 11�02� 11�02� 110202 120201 191 M 10" 10" 6" INTERNAL RECYCLE 10" I S 6"-PVC-IR-002 Cj1 CV-1104 PV-1108 PV-1111 \ TO PAX-01 PV-1Dj�1 C C At 10" x 6" 6 SHT 6. ❑K P-1 1-04 FF/IR PUMP 04 rFI�sc(STANDBY) I 1 110201 191 110201 110 01 rFE L FCV TSH MSH MOT 110201 110201 110201 110201 © 110201 ❑K M 10" 10" r 6" FEED FORWARD RAS py M \1 6"-PVC-FF-002 J 1 � 10" CV-1 PV-1107 � PV-1112 � TO AXP-01 E 1 10"-PVC-FF/IR-002 / ` � S 10 x 6 6 SHT 10. FROM PA-02 PV-1103 SHT 8. V ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 P-11-03 FF/IR PUMP 03 FINAL PLAN - NOT RELEASED FOR (DUTY) CONSTRUCTION ❑K MICHAEL C. GALLANT, PE, PA FE •S�••.`� PO BOX 4039 ¢� S Lr SURF CITY, NC 28445 139sm IO2 72 910-448-1046 • IN °��.`` gallantmc@yahoo.com �qF� C..G P ``� °""111"" % NC FIRM#: C-1989 6/4/24 REV NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 REVISIONS DRAWN DATE DESCRIPTION DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC FF & IR PUMPS SIZE CONTRACT NO. DRAWING NO. REV. D — HNC-1-09 C SCALE SHEET NO. N/A 9—Of-19 1 7 19i 0 1 El 3 HIGH LEVEL LOW LEVEL AL D 090101 090101 D MBR OIT MBR OIT MBR PLC MBR PLC MCC— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — I — — — — — — — — — — — — — — MCC C M"q MILA PROCESS AIR B FROM PACKAGE / S COMPRESSOR I CARBON B2 FROM TANK 003 1/2"-TUBE-CARB-001 SHT. 18 FEED FORWARD H 1 FROM FF/IR PUMPS 6"-PVC-FF-001 SHT 9. FEED FORWARD J 1 FROM FF/IR PUMPS 6"-PVC-FF-002 SHT 9. ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 I 7 I 6 If CB-09-01 ENVIROMIX COURSE BUBBLE DIFFUSER 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 AXP-01 POST -ANOXIC BASIN 36,595 GAL SWD 18'-0" FINAL PLAN - NOT RELEASED FOR CONSTRUCTION Pp��N,CAR'b,O MICHAEL C. GALLANT, PE, PA PO BOX 4039 ;Q S L �� SURF CITY, NC 28445 102 72 910-448-1046 Cgallantmc@yahoo.com NC FIRM#: C-1989 6/4/24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 REVISIONS REV DESCRIPTION NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 5 t 4 (LSH (LSL 090101 090101 X X 00 0 0 00 0 0 0 0 0 0 DRAWN DATE DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 C RAS \ K1 TO MB-01 I SHT 11. RAS B L1 TO MB-02 SHT 12. A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC POST -ANOXIC BASIN SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-10 C SCALE SHEET NO. N/A 10-of-19 1 D MBR OIT MBR PLC MCC X1 CIP FROM CIP PUMP>-4 3"-PVC-CIP-001 SHT 16. T1 SCOUR AIR FROM SCA BLOWERV�� 6"-304SS-SCA-001 C SHT 15. C I K 1 RAS FROM AXP-01 SHT 10. ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 7 6 5 j 4 3 1 7 VENT TO ATM Q ABOVE BASIN N oFK m I T Q O ❑ K m Q (o i C)❑ C) �LL m I LE r W Q � _ V 10 � g] c �c LL m I T W ■■ n r Q Q Q Q Q Q Q Q W co J(DK� K K� K K K K K m m m m m m m m -- -- -- -- -- -- -- -- Z Z Z Z S S S S I-- -- I-- -- 1 1-- -- SMU-01-01 SMU-01-03 SMU-01-02 (PHASE 1) (FUTURE) (PHASE 1) ❑K ❑K ❑K MB-01 MBR BASIN 01 FINAL PLAN - NOT RELEASED FOR 38,020 GAL CONSTRUCTION SWD 17'-0" Pp��N,CAR'b,O MICHAEL C. GALLANT, PE, PA O� REV FE'si'••.! PO BOX 4039 ;Q S L �� SURF CITY, NC 28445 raf,,Sm 102 72 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-19896/4/24 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 5 t 4 I� "`-- S M U-01-04 (FUTURE) ❑K REVISIONS DESCRIPTION LOW LEVEL AL 100101 D MBR OIT DRAWN DATE DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 8"-PVC-PRM-001 MBR PLC MCC PERMEATE \ M 1 TO COLLECTION I SHT 13. C C 10"-DIP-RAS-001 �I N 1 RAS / O PA-01 I SHT 7. �� 2"-PVC-WAS-001 P 1S WAS B SHT 14. A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC MEMBRANE BASIN 01 SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-11 C SCALE SHEET NO. N/A 11 -Of-19 1 8 I 7 1 6 I 5 4 I 3 I 1 LOW LEVEL AL D 100201 D MBR OIT MBR OIT MBR PLC J\ MBR PLC MCC MCC Y 1 FROM \� 3"-PVC-CIP-002 FROM CIP PUMP SHT 16. SCOUR AIR U 1 6"-304SS-SCA-002 FROM SCA BLOWER C SHT 15. C O m cn W m m m m < c� co v m �,,� Io ❑K co � �,,� � o ❑K co ❑K c o C r> o LL m m m © > -- m VENT TO ATM co ABOVE BASIN - N C)C) F - RAS \ co 0 L1 FROM AXP-01 SHT 10. 8"-PVC-PRM-002 Q1 PERMEATE W I TO COLLECTION SHT 13. O = LS L m U) 100201 ❑K W Lo m co m m m co o m clim -Y—, \ RAS K� K K� K K� K �L_—� 10"-D I P-RAS-002 co LL �o �o �o �o �o ❑ �o ❑K =co ❑K C R1 TO PA-02 ii LL ii LL ii ii ii LL SHT 8. m m m m m m m m C �� 2"-WAS-PRM-002SS1 HS PUMPS SHT 14. -- -- -- -- -- -- -- -- Z Z Z Z ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 7 S S S S M U-02-01 SMU-02-03 SMU-02-02 (PHASE 1) (FUTURE) (PHASE 1) ❑K ❑K ❑K MB-02 MBR BASIN 02 38,020 GAL FINAL PLAN - NOT RELEASED FOR SWD 17'-0" CONSTRUCTION "" MICHAEL C. GALLANT, PE, PA REV FE sPO BOX 4039 .� S L �� SURF CITY, NC 28445 rj9sm l02 72 910-448-1046 F"'"C"�,P�gallantmc@yahoo.com /1'""""0%NC FIRM#: C-19896/4/24 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 I 5 t 4 S S M U-02-04 (FUTURE) ❑K REVISIONS DRAWN DATE DESCRIPTION DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE I 3 I 2 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC MEMBRANE BASIN 02 SIZE CONTRACT NO. DRAWING NO. REV. D — HNC-1-12 C SCALE SHEET NO. N/A 12—of-19 I � C C A 0 8 7 TYP. 2 n I I HIGH TMP PAH 130101 TMP rpi 1�3�0101 MBR OIT MBR PLC MCC — — — — — — — — — — (-PT 130101 PERMEATE M 1 FROM MB-01 8 PVC-PRM-001 l SHT 11. (-PT 130201 I� PERMEATE 8"-PVC-PRM-002 � Q 1 FROM MB-02 SHT 12. ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 I 7 6 TYP. 3 n I FAIL YA 130101 REMOTE RUN RUNNING YI YC YI 130101 130101 130101 4" BF-1 30 8" x 4"101 o - - LL m 5 4 3 TYP. 2 TYP. 2 I n I I FAIL YA 130102 FLOW CLOSE POSITION POSITION REM LOC FICA rz I cl rl Cl YC YI 130101 130101 130101 130102 130101 3 HS VFD 130101 130101 PG 130101 O O P-13-01 PERMEATE PUMP 01 (DUTY) 000 GPM ❑K \ PG 130301 o 81, x 4" 0 O �m P-13-03 PERMEATE PUMP 03 (STANDBY) 000 GPM ❑K PG \ 130201 © \ 4" /O BF-1304 O 8'x4 ❑ P-13-02 PERMEATE PUMP 02 (DUTY) 000 GPM ❑K TURBIDITY HIGH AAH 130101 TURBIDITY AI 130101 ZSC(FCV�_ 01 AIT FIT 13�� 130101 13 13� 130101 X AIR RLS VLV CV HS AS READ PG (F�E 130101 130102 _ o - O 130102 © 130101 �� i\ M N T M > m 4" 4" 4" 4" \ CV-1301 BF-1305 A 4„ BF-1309 BF-1311 A © © ❑K PG 130302 4" CV- 03 PG 4" BF-1 30 8" x 4"101 o - - LL m 5 4 3 TYP. 2 TYP. 2 I n I I FAIL YA 130102 FLOW CLOSE POSITION POSITION REM LOC FICA rz I cl rl Cl YC YI 130101 130101 130101 130102 130101 3 HS VFD 130101 130101 PG 130101 O O P-13-01 PERMEATE PUMP 01 (DUTY) 000 GPM ❑K \ PG 130301 o 81, x 4" 0 O �m P-13-03 PERMEATE PUMP 03 (STANDBY) 000 GPM ❑K PG \ 130201 © \ 4" /O BF-1304 O 8'x4 ❑ P-13-02 PERMEATE PUMP 02 (DUTY) 000 GPM ❑K TURBIDITY HIGH AAH 130101 TURBIDITY AI 130101 ZSC(FCV�_ 01 AIT FIT 13�� 130101 13 13� 130101 X AIR RLS VLV CV HS AS READ PG (F�E 130101 130102 _ o - O 130102 © 130101 �� i\ M N T M > m 4" 4" 4" 4" \ CV-1301 BF-1305 A 4„ BF-1309 BF-1311 A © © ❑K PG 130302 4" CV- 03 PG 3 HS VFD 130101 130101 PG 130101 O O P-13-01 PERMEATE PUMP 01 (DUTY) 000 GPM ❑K \ PG 130301 o 81, x 4" 0 O �m P-13-03 PERMEATE PUMP 03 (STANDBY) 000 GPM ❑K PG \ 130201 © \ 4" /O BF-1304 O 8'x4 ❑ P-13-02 PERMEATE PUMP 02 (DUTY) 000 GPM ❑K TURBIDITY HIGH AAH 130101 TURBIDITY AI 130101 ZSC(FCV�_ 01 AIT FIT 13�� 130101 13 13� 130101 X AIR RLS VLV CV HS AS READ PG (F�E 130101 130102 _ o - O 130102 © 130101 �� i\ M N T M > m 4" 4" 4" 4" \ CV-1301 BF-1305 A 4„ BF-1309 BF-1311 A © © ❑K PG 130302 4" CV- 03 PG 130202 4" 4" CV-1302 BF-1306 ti O M - LL m o 00 _ �o M - - LL m ZSC �FCV FIT 13300201 130201 130201 rFE CV HS - 202 130201 FK-1 1 13� ❑K M r 4" 4" 4„ BF-1310 BF-1312 RI FINAL PLAN - NOT RELEASED FOR CONSTRUCTION MICHAEL C. GALLANT, PE, PA FE s7�°<% PO BOX 4039 I, S L h� SURF CITY, NC 28445 102 72 910-448-1046 IN '��.`� gallantmc@yahoo.com .qF� •C••Gp, ��` NC FIRM#: C-1989 I 7/23/24 REV NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 6 I 5 t 4 REVISIONS DESCRIPTION z Q a Lu m H m 7 YD R 4"-PVC-PERMEATE DRAWN DATE DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 1" PVC -DRAIN MBR OIT MBR PLC MCC PERMEATE TO M2 WASHWATER LIFT ST . SHT 19 M3 �TURBID. METER DRAM TO WW LIFT STA I SHT 19 It C A A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC PERMEATE COLLECTION SIZE CONTRACT NO. DRAWING NO. REV. D — HNC-1-13 C SCALE SHEET NO. N/A 13—of-19 1 8 I 7 I 6 I 5 4 I 3 I I 1 TYP. 2 TYP. 2 A I I I I FAIL FAIL YA ZA L1_7�0101 170102 \---./ FLOW OPEN/CLOSE CLOSE OPEN RUN RUNNING REMOTE FICA YC ZIC ZIO YC YI YI 170101 170101 170101 170101 D 170101 170101 170101 D MBR OIT MBR OIT MBR PLC MBR PLC VFD 170101 d S 170101 MCC MCC HOR C C PG 170101 ZSC 170101 2" 2" �.i ZSO CV-1701 BV-1704 FIT 170101 170101 XV WAS 2" 170E01 Pi 170101 KMU OTHERS FROM MB-01 2"-PVC-WAS-001 ` Da ► ❑K M SHT 11. BV-1702 \�\ 2 Al TO FINE SCREENS M 3" PVC-WAS-PRM-001 P -17 - 01 2„ PV-1701 2" 3" SHT 05 B s 1 WAS 2"-PVC-WAS-002 FROM MB-02 SHT 12. ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 No- 7 WAS PUMP PG (DUTY) 170201 000 GPM ❑K 2" BV-1703 P-17-02 WAS PUMP (STANDBY) 000 GPM 191 2" 2" CV-1702 BV-1705 FINAL PLAN - NOT RELEASED FOR CONSTRUCTION MICHAEL C. GALLANT, PE, PA FE sPO BOX 4039 .� S L �� SURF CITY, NC 28445 ` l02 72 910-448-1046 C, •`` gallantmc@yahoo.com NC FIRM#: C-1989 6/4/24 I:a2L9 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 6 I 5 t 4 ❑K x I ZSC 170201 rz So FIT 170201 170201 F �E --( xv 170201 170201 KMU OTHERS M J2" M , �-- 3"-WAS-PRM-DIG-001'� 2„ PV-1702 K REVISIONS DRAWN DATE DESCRIPTION DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE I 3 I 2 C WAS TO DIGESTER A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC WAS PUMPS SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-14 C SCALE SHEET NO. N/A 14-of-19 I 1 C M"q MILI C I 8 I 7 I TYP. 5 A I I FAIL YA 14010 SPEED RUNNING RUNNING AUTO HI TEMP SC YI YL YL TAH 1401010 14010 14010 14010 14010 MBR OIT AO\I DI \I 140101 140101 140101 MBR PLC (VFD HS I 140101 140101 HOR MCC c>�o FAN T SH L TSH 140101 140102 2MOT B -1 4 - 01 I 140101 ('� TG PG 2" 140102 140101 MBR BLOWER 01 I 140101 PRV-1401 (DUTY) 6" K CV-1401 FAN I L TSH TSH 140201 140202 MOT B -14 - 0 2 I 140201 ( PG �GG MBR BLOWER 02 I 140202 140201 2„ (DUTY) 140201PRV-1402 6" K CV-1402 FAN I L TSH TSH 150101 150102 MOT B-15-01 I 150101 PG TG PG 2„ 150102 150101 PA BLOWER 01 I 150101 PRV-1501 (DUTY) 6" K CV-1501 FAN I L TSH TSH 150201 150202 MOT 150201 B-15-02 I (�G) TG PA BLOWER 02 I PG 2„ 150202 150201 (DUTY) 150201 PRV-1 502 6" K CV-1502 FAN I L TSH TSH 140301 140302 MOT B -14 - 0 3 I 140301PG TG PG 2„ 140302 140301 MBR/PA BLOWER 01 I 140301 PRV-1403 (COMMON STANDBY) 6" K CV-1403 ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 C9i 0 I I 6" BF-1401 6" BF-1402 I I 8" BF-1501 8" BF-1502 1 o Lo bo m IT o Lo bo m s ow No No - FINAL PLAN - NOT RELEASED FOR CONSTRUCTION Pp��N,CAR'b,O MICHAEL C. GALLANT, PE, PA PO BOX 4039 ;Q S L �� SURF CITY, NC 28445 102 72 910-448-1046 ,qF*'C"�,gallantmc@yahoo.com �I'"""""�°� NC FIRM#: C-1989 6/4/24 7 1 6 1 5 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 t 0 TYP. 4 I I HIGH TMP PAH 14010 TMP PI \14010 REV 4 L4 PIT 140103 ❑K m PIT 140203 N m PIT 150101 fcc ❑ PIT 150201 N O ❑ m REVISIONS DESCRIPTION 3 1 TYP. 2 LOW AIR YA 14010 FLOW rFICQ 14010 D MBR OIT — MBR PLC MCC (F�IT 140101 (FE 140101 ❑K IT 6"-304SS-SCA-001 T1 SCOUR AIR \ C "�TO MB-01 I SHT 11. (FIT 140201 (FE 140201 ❑K IT 6"-304SS-SCA-002 U SCOUR AIR \ TO MB-02 I SHT 12. H V1 PROCESS AIR \ 8"-304SS-PA-001 I TO PA-01 B SHT 7. PROCESS AIR 8"-304SS-PA-002 W1 i TO PA-02 SHT 8. DRAWN DATE HAMPSTEAD WWTP EXPANSION DATE APPROVED HAMPSTEAD NC CHECKED DATE MBR & PA BLOWERS APPROVED DATE SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-15 C APPROVED DATE SCALE SHEET NO. N/A 15-of-19 3 I 2 I 1 Ul 8 1 7 1 6 1 5 j 4 1 3 D MBR OIT C A 0 MBR PLC MCC PW-001 W2 FROM WWLS 3"-PVC-PW-001 J SHT 19 ❑K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 FAIL ZA 160101 REM LOC OPEN/CLOSE CLOSE OPEN YI YC C r—z I ZIO 160101 160101 160101 160101 FLOW FICO 160101 D MBR OIT MBR PLC MCC • 3"-PVC-CIP-001 —CIP d Xi I TO MB-01 ) C SHT 11. � co ZSC m coCD m 160101 rzs O w ` 3"-PVC-CIP-002 Yl PG TO MB-02 3„ 160101 SHT 12. XV O m PRV-1601 160101 CD 1 ❑K HS LL co 03 160101 ❑K Y (FIT 160101 ❑K w J' ('FE _ o--ca_ M ❑K 160101 3" PVC INLINE MIXER ❑K 3/4" CHEMICAL INJECTION QUILL s FN x M N O M F >' 00 3/4" ROTOMETER r P-1 6-01 CHEMICAL DRUM PUMPS ( 1 DUTY/ 1 SHELF SPARE) ❑K DR 000 GPM 00 HP "3/4" BV- 01 ❑K FINAL PLAN - NOT RELEASED FOR CONSTRUCTION REVISIONS p�•``N'CAR���p,� MICHAEL C. GALLANT, PE, PA REV DESCRIPTION 'c�F� S%�.• PO BOX 4039 rig.,m ' � SURF CITY, NC 28445 lO2 72 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-19897/23/24 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 I 3 DRAWN DATE DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 0 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC CLEAN -IN -PLACE SIZE CONTRACT NO. DRAWING NO. REV. D - HNC-1-16 C SCALE SHEET NO. N/A 16-of-19 1 Ci D MBR OIT C C A MBR PLC MCC �K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 7 1 6 I 5 4 I 3 1 I 1 TK-001 ALUM STORAGE TANK ALKALINITY STORAGE TANK FINAL PLAN - NOT RELEASED F60 CONSTRUCTION "ollit "'��� MICHAEL C. GALLANT, PE, PA ;Z:F PO BOX 4039 IS L I r l02 SURF CITY, NC 28445 72 910-448-1046 �• q IN ��.�� gallantmc@yahoo.com NC FIRM#: C-1989 6/4/24 TYP. 2 I I FAIL YA 101 RUN RUNNING REMOTE YC YI YI 190101 190101 190101 D MBR OIT MBR PLC JC 190101 ds J — 190101 Y HOR MCC P-19-01 ALUM INJECTION PUMP 01 (DUTY) ❑K P-19-02 ALUM INJECTION PUMP 02 (SHELF SPARE) ❑K (P—M P 190102 pool P-19-03 NaOH INJECTION PUMP 01 (DUTY) ❑K P-19-04 NaOH INJECTION PUMP 02 (SHELF SPARE) ❑K REVISIONS REV DESCRIPTION NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 DRAWN DATE DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 C1/2"-TUBE-ALUM-001 Zj ALUM PA-01 SHT. 7 > C,TO �ALUM 1/2"-TUBE-ALUM-002"Z2 TO PA-02 SHT. 8 0 ALKALINITY C 1/2"-TUBE-NaOH-001 A2 TO PA-01 SHT. 7 ALKALINITY 1/2"-TUBE-NaOH-002 A3 TO PA-02 SHT. 8 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC ALUM & NaOH INJECTION SIZE CONTRACT NO. DRAWING NO. REV. D — HNC-1-17 C SCALE SHEET NO. N/A 17—of-19 1 D MBR OIT C C A Ci 7 wl wl 1 Ill TYP. 2 I I FAIL YA 11� RUN RUNNING REMOTE YC YI YI 190103 190103 190103 3 D MBR OIT MBR PLC MBR PLC JC 190103 dsHS J 190103 Y HOR �K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 i TK-003 CARBON STORAGE TANK (P-M P 190103 P-19-05 CARBON INJECTION PUMP 01 (DUTY) ❑K P-19-06 CARBON INJECTION PUMP 02 (SHELF SPARE) ❑K PMP 19� P-19-07 PERACETIC ACID PUMP 01 (DUTY) TK-004 P-19-08 PERACTIC ACID PERACETIC ACID PUMP 02 FINAL PLAN — NOT RELEASED F[RR (SHELF SPARE) CONSTRUCTION C�,O MICHAEL C. GALLANT, PE, PA REVISIONS REV DESCRIPTION ;FE •SSG; PO BOX 4039 S L SURF CITY, NC 28445 139sm l02 72 910-448-1046 gallantmc@yahoo.com NC FIRM#: C-1989 6/4/24 NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 DRAWN DATE DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 C 1/2"-TUBE-CARB-001 CARBON C B2 AXP-1 SHT. 10 0 1/2"-TUBE-PERA-001 B3 PERACTIC ACID \ TO WW LS SHT. 19 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC CARBON INJECTION SIZE CONTRACT NO. DRAWING NO. REV. D — HNC-1-18 C SCALE SHEET NO. N/A 18—of-19 1 Ci D MBR OIT 7 wl wl 1 MBR PLC — — — — — — — — — — — — — — — — — — — — — — — — — MCC C B PERMEATE FROM M2 PERMEATE PUMPS 4"-PVC-PERMEATE N SHT 13 RAIN M3 DURBIDI YOMETER 1" PVC -DRAIN SHT 13 PERACTIC ACID B3 FROM TANK 004 1/2"-TUBE-PERA-001 SHT. 18 A �K PROVIDED BY KUBOTA © PROVIDED BY OTHERS/CONTRACTOR 8 1 Ill CV-10202 BV-10202 © © I� 2„ 2„ 2"xx 3" CV-10102 BV-1010� © © TRANSITION TO PVC PRIOR TO VALVE VAULT C 2"-PVC-PW-002 ) 2" 2" At I CV-10101 BV-1010� I 2" 2" CV-10201 BV-10201 0 � � CV C)C)C)O O CV O ► U U U) U) IT C) C) CV CV F E�2] F E�2] loop CI I� CI I� CI I� CI I� P-10-04 P-10-3 P-10-02 P-10-1 CIP SUPPLY PUMP CIP SUPPLY PUMP CIP SUPPLY PUMP CIP SUPPLY PUMP (STANDBY) (DUTY) (STANDBY) (DUTY) WASH WATER LIFT STATION FINAL PLAN — NOT RELEASED FOR 10' DIA PRE CAST WET WELL CONSTRUCTION " MICHAEL C. GALLANT, PE, PA PO BOX 4039 S L I SURF CITY, NC 28445 rigs, 102 72 910-448-1046IN ��.�� gallantmc@yahoo.com NC FIRM#: C-1989 6/4/24 REV NC FIRM C-1989 AL FIRM CA-4338- E NC REG NO. 25572 AL REG NO. 32178 7 I 6 I 5 t 4 3 D MBR OIT MBR PLC MCC C HP-10-01 HT HYDROPNEUMATIC TANK Ps- 10-01 PRESSURE SWITCH P� © ` I W2 PW-001 TO \ 3"-PVC-PW-001 /\ )II I CIP SHT. 16 CN O 0 U CN 2"-PVC-PW-002 PW-002 TO FINE SCREENS \ SHT. 5 / 12"-PVC-PRM-001 �` I W1 EFFLUENT \ B ) �TO HRI BASINS / REVISIONS DRAWN DATE DESCRIPTION DATE APPROVED CHECKED DATE APPROVED DATE APPROVED DATE 3 I 2 A HAMPSTEAD WWTP EXPANSION HAMPSTEAD, NC WASH WATER LIFT STATION SIZE CONTRACT NO. DRAWING NO. REV. D — HNC-1-19 C SCALE SHEET NO. N/A 19—Of-19 1 K 4712 G 882 - 886 (5) This Document eRecordedo. DOC 20063703 05/21/2020 08:26:14 AM A Fee: $26.00 Pp.nriAr (.nHntv DocType: MEMO . _..�_. _..�...,NorthCarolinaCarolina.1 Sharon Lear Will STATE OF NORTH CAROLINA COUNTY OF PENDER IL .7 I � 1�� 1 �� A 1• k OF New oughby, Register of Deeds Tax: $0.00 AGREEWNT AND EASEMENT (this -on M n 1 0 9 N Agmllli�lll nt for M131nizilance PmVision of 6 - , Ob F 7 i Pr M�VP - i L _ y &;4 I'IT;IIIllll� Ito I W jdu - - 9 2014)9 betwecm the t'ies I doll I me 9 74 - -a IL 40 t (s I " .1 ;rT Or 411P iP T 41111 4 1 -V a 0 4 bjV1111 %A1 �M 4-F4 i II 1W 1 4 ` -11L- 4 T 44 ) r . I I � I k j I I I I I - L I I _ A, @4 j;�;� I r r -� lot oil- � t - - Al) 0 AL tj r I r -.vr 1 7 r low 1� it 1F-'O - - - , ( _ fj .. WE AL V 40 - over. across. under. upon and throu¢h the Impoundment Property for the purpose of compl { - rtj 4 do OL 1 4d y � -t wr - - i submitted electronically by "Murchison, Taylor & Gibson, PLLC" in compliance with North Carolina statutes governing recordable and the terms of the submitter agreement with the Fender County documents Register of Deeds. ■ f 273197 j BK 4712 PG 883 DOC# 20063703 until the Agreement has been terminated as set forffi above. Pluris shall deliver to BFF a written recordable release of this Memorandum within thirty (30) days after the termination of the Agreement. [Execution and acknowledgment pagesfollowl w IP 273197 2 BK 4712 PG 884 DOC# 20063703 IN WITNESS WHEREOF, the parties have caused this Memorandum to be executed to be effective as of the date of the Agreement as set forth above. PLURIS.qP PLURI By4 : Name: Mai I itle Managing Member STATE OF TEXAS EAL] COUNTY OF (County where acknowledgment taken) ti I certify that the following person(s) personally appeared before me this day, each acknowledging to me that he or she voluntarily signed the foregoing document for the purposes stated therein and in the capacity(t'es) indicated above: Maurice Gallarda. Date: [OFFICIAL SEAL] MICHELLE KING �a 40 4P s°{'�� NotallotaryPublic, State of Texas o �:6 do Comm. Expires 04-ml4m.2024 °;SX�+ Notafy ID 129689327 Official Signature of Notary: Printed Name of Notary: My commission expires,, 273197 3 kt� [As name pc 4 Ll OR I L4 OC3� BK 4712 PG 885 DOC# 20063703 BFPD9 BLAKE FARM POND, LLC ve B wr SEAL r k Nam—e..:.94 ■ .�► Title. Manager STATE OF NORTH CAROLMA COUNTYOF (County where adrnvwledpneat taken) Icertifyth thefollow" g personally appeared before me this day, each acknowledging to me that be or she voluntarily signed the foregoing document for the purposes stated therein and in- the 0 - capacity(les) indicated above: P. w=uting document, not thelk title]. Date i5 1 I q126 zo [OFFICIAL SEAL] F Ir Official Signature0-f Notary: Printed Name of Notary: _[NOTE: Insect the name of the party so JAs mine 00 oseal I kc.ca \/Y i ot er jAjsin7a pars on seal]] My commission expires:: _� 7Lo 273197 4 a BK 4712 PG 886 DOC# 20063703 W EXIiIBIT A To Memorandum Description of Impoundment Property BEING ALL OF Tract "C" 10. 14 acres Division, Tract "A" and Tract "B" and CaCarolina"recorded in Map Book 56 273197 +/w as shown on the map entitled "Pander 1164, LLC Tract "C", Topsail Township, Pander County, North Page 87, Pender County Registry. W-1305, Sub 0 0 U J New Agreement for Maintenance and Provision of Information Relating to Surplus Groundwater Impoundment Between Blake Farm Pond, LLC and Pluris Hampstead, LLC Pender County, North LIL Carolina This New Agreement for Maintenance of Surplus Groundwater Impoundment ("Agreement") is entered into this the Z$ day of August, 2017, by and between Blake Farm Pond, LLC, with principal offices at 1202 Eastwood Road, Wilmington, NC 28403 ("Owner") and Piuris Hampstead, LLC ("Utility"). This Agreement replaces in its entirety the Agreement for Maintenance of Surplus Groundwater Impoundment entered into by Co Owner and Utility on June 9, 2014. o 04 WITNESSETH I, - CD WHEREAS, the Owner or its affiliate has submitted a plan (the "Plan") to the North Carolina Department of Environmental Quality ("DEQ") (formerly known as the Department of Environment and Natural Resources ("DENR")) for a project known as a Surplus Groundwater Impoundment (the "SGI"), which includes a groundwater detention pond, as further described on Exhibit A. WHEREAS, the Pian required Utility to send all of the groundwater resulting from the Utility's high rate infiltration basins to the SGI, and requires Owner to receive all of the groundwater resulting from the Utility's high rate infiltration basins; WHEREAS, Utility was issued Permit No. WQ0031287 on April 29, 2015, for the construction and operation of the Pluris Hampstead wastewater treatment, high rate infiltration facilities and a groundwater lowering system effluent storage pond (the "WWTF"), which permit includes certain operation, maintenance, monitoring and reporting requirements (the "Wastewater Permit"). The "groundwater lowering system effluent storage pond" as referenced in the Wastewater Permit documents is referred to as the "SGI" in this Agreement; WHEREAS, Utility was issued Nf DES Permit NCO089524 on October 9, 2015, which allows treated wastewater to be discharged to a nearby creek and which permit includes certain monitoring and reporting requirements (the "Discharge Permit"); WHEREAS, the Owner will install the SGI and will comply with all erosion and sediment control regulations adopted by DEQ; WHEREAS, it is required by DEQ that the Owner enter into an agreement whereby the Utility will maintain certain components of the SGI; and WHEREAS, both parties desire to ensure sufficient maintenance to maintain the structural integrity and the proper function of the SGI. NOW, THEREFORE, for and in consideration of the mutual covenants stated below, the parties agree as follows: Article I Representations and Warranties Owner represents and warrants; Owner has the full right, power and authority to execute and deliver this Agreement and to perform the Owner's obligations under this Agreement, and neither the execution of nor the carrying out of the terms of this Agreement will constitute a breach or default under any agreement, document or other obligation to which the Owner is a party or otherwise bound or any applicable law, rule or regulation. 2. This Agreement is valid, legally binding on the Owner and enforceable in accordance with its terms. Pond Maintenance Agreement 3. The Owner owns prior to any construction activity commencing, the Owner's Property (hereinafter defined) in fee simple. 4. Neither Owner nor any entity or Individual affiliated with Owner has executed any agreement with any other parties, or made any representations to any such parties whereby such parties have acquired any interest in the SGI either installed or to be installed under this Agreement. Utility represents and warrants: Utility has the full right, power and authority to execute and deliver this Agreement and to perform the Utility's obligations under this Agreement, and neither the execution of nor the carrying out of the terms of this Agreement will constitute a breach or default under any agreement, document or other obligation to which the Utility is a party or otherwise bound or any applicable law, rule or regulation. 2. This Agreement is valid, legally binding on the Utility and enforceable in accordance with its terms. The Utility has constructed the WWTF. 4. Neither Utility nor any entity or individual affiliated with Utility has executed any agreement with any other parties, or made any representations to any such parties whereby such parties have acquired any interest in Utility's high rate infiltration basins and related treatment plant either installed or to be installed under this Agreement. 5. The Wastewater Permit and Discharge Permit have been validly issued by governmental authorities, are in full force and effect, and permit the Utility to engage in the activities provided for therein, and Utility is and shall be responsible at its sole cost and expense for maintaining the effectiveness and validity of said permits necessary to operate the WWTF including the renewal and/or reissuance of same during the term of this Agreement. Article If Obligations and Construction of Facilities by Owner 1. Owner will construct the SGI on Owner's Property located in Pender County, North Carolina, as more particularly described on Exhibit B (the "Owner's Property") in accordance with all applicable laws, standards, requirements, rules and regulations, including all requirements of any municipality, county, or state government or agency ("Governmental Standards"), and will comply with all erosion and sediment control regulations adopted by DEQ or other governmental authority with applicable jurisdiction. 2. Owner shall accept all groundwater flow, not resulting from infiltration, resulting from the Utility's high rate infiltration basins constructed by the Utility on its property located adjacent to the Owner's Property (the "Utility Property"] and shall not attempt to obstruct or limit the flow and receipt of any such groundwater. There is no minimum or maximum flow volume to be received into the SGI. 3. Owner shall, at its sole cost and expense, construct and install all necessary features of the SGI, including but not limited to service pipelines with valves, disconnecticlean outs, and all other soil related work such as grading and slope construction necessary for the SGI (in accordance with applicable Governmental Standards). 4. Owner shall construct the SGI in accordance with designs provided by the Utility, and shall provide as -built data and drawings, soil reports and other certifications requested by the Utility in order to document compliance with the approved designs. The certification shall be made by a professional engineer and shall certify that the structure has been designed and constructed in accordance with 2 Pond Maintenance Agreement the approved plans and sound engineering principles and practices. Where the as -built condition varies significantly from the approved design, appropriately revised calculations will also be provided by the engineer. 5. Owner shall establish a robust ground cover, as specified in the Erosion and Control Plan approved by DEQ or other governmental authority with applicable jurisdiction, on all slopes surrounding the SGI. 6. Owner will convey to the Utility or provide by recorded subdivision plats such easements or rights of way as may be reasonably necessary for the Utility's performance of its obligations under this Agreement, in a form satisfactory to Utility's legal counsel. Such easements will be permanent, assignable, non- exclusive easements satisfactory to Utility, authorizing Utility to perform its Maintenance Obligations under this Agreement and providing reasonably adequate rights of access and working space for such purposes. In addition, Owner will grant such easements to electric utility providers as may be necessary for the operation of the SGI or for Utility's performance of the Maintenance Obligations. 7. Owner shall record this Agreement in the land records of Pender County at Owner's expense, upon execution of this Agreement by all parties. 8. Utility will provide 18 months prior written notice to Owner of the date by which Utility anticipates that completion of expansion of the capacity of the SGI will be necessary to accept all groundwater flow from Utility's high rate infiltration basins on the Utility Property (°the Expansion Completion Date"). Within one month of the date of Utility's written notice to Owner, Owner shall inform Utility in writing as to whether it intends to expand the capacity of the SGI. If Owner informs Utility that it does intend to expand the SGI capacity, then within nine months of the date of Utility's written notice, Owner shall have completed the design of the expansion, secured all necessary permits for the expansion and commenced construction of the expansion. If Owner fails to comply with the foregoing requirements for expansion of the capacity of the SGI as necessary in the future in order to accept all groundwater flow from Utility's high rate infiltration basins on the Utility Property, then Utility may contract with other persons or entities to establish additional surplus groundwater impoundment facilities as necessary to accommodate Utility's groundwater flow that the Owner's SGI cannot accommodate. Owner has the option of securing an area adequate for use to waste the surplus groundwater flow as an alternative to physically expanding capacity of the SGI. If Owner chooses this option, it shall so advise utility in writing and shall have secured the right to use such area and any required permitting within nine months of the date of Utility's written notice. Article III Obligations of the Utility 1. Utility has constructed, at its expense and at no expense to Owner, a gravity interconnect pipeline running from the WWTF to the SGI (the "Pipeline"), and Utility (i) monitor water and effluent levels in the SGI in accordance with the Wastewater Permit and Discharge Permit requirements, and (ii) provide groundwater flow resulting from the Utility's high rate infiltration basins on the Utility Property to the Owners SGI via the Pipeline, at no cost to the Owner. Utility shall not attempt to divert or otherwise transfer any groundwater flow from Utility's high rate infiltration basins on the Utility Property to any other party, or otherwise to reduce the amount of groundwater flow to be provided to Owner by diversion of sewer services to other plants or treatment facilities or distribution or transmission systems, except under the circumstances addressed in Article II 8. 3 Pond Maintenance Agreement 2. Requirements Relating to Development Agreements, 2.1 A. Utility shall provide Owner with copies of all sanitary sewer agreements between Utility and Developers or other landowners whose properties are or will be served by the Utility (each a "Developer Agreement) entered into prior to the date of this Agreement. B. Utility shall provide Owner with copies of each Development Agreement entered into between Utility and Developers or other landowners whose properties will be served by the Utility entered into after the date of this Agreement. C. Utility may provide copies of such agreements to Owner by any reasonable means, including but not for limited to, via attachment to an e-mail in .PDF format and delivered to the following e-mail address: UDA aBtrasklandco.com. D. Owner shall sign a confidentiality agreement in a form acceptable to Utility preventing disclosure to third -parties by Owner of any Development Agreements provided by Utility to Owner. E. Utility will provide to Owner on a monthly basis a copy of the spreadsheet maintained by Utility for its own purposes, which spreadsheet includes the following data for each development served by Utility pursuant to a Development Agreement: • The number of permitted connections made; and • Any additional bedroom gallons -per -day permitted after the Developer Agreement was signed (i.e., a 5-bedroom home was permitted/buiR rather than a 3-bedroom home). A. All Development Agreements entered into between Utility and Developers or other landowners after the date of this Agreement shall include language requiring an "Agreement for Alternative Retum Groundwater" as an addendum to the Development Agreement ("Addendum Agreement") and payment to Owner if the landowner does not construct reuse lines to serve his/her property. B. Development Agreements entered into after the date of this Agreement shall include the following language: Developer shall construct a reuse return line and facilities on the project site to dispose of groundwater in a volume commensurate with Developer's development usage. As an alternative to Developer constructing the reuse line, Developer may, at its own expense, present to Utility an alternative plan to have its reuse water returned to a property other than Developer's through agreement with and payment to Blake Farm Pond. These payments are solely the responsibility of the Developer and are payable directly to Blake Farm Pond LLC at the time the Development Agreement is executed. C. If a Developer or landowner does not agree to construct the required reuse return lines to serve his or her property, he/she shall execute the Addendum Agreement, and a full and complete copy of the Addendum Agreement must be presented to the 4 Pond Maintenance Agreement Owner with the Owner countersigning the Addendum Agreement thereby acknowledging the Developer's election to utilize Owners SGI and to pay Owner pursuant to the terms of the Addendum Agreement. 3. Utility shall maintain the SGI by performing the following tasks (the "Maintenance Obligations"), subject to the limitations contained in this Agreement: A. Grass. All grass will be mowed at least bi-monthly from May to October each year. Ground cover shall be maintained at a reasonable height during this period and shall not be allowed to exceed 12" in height. B. Fertilizer Application. Fertilizer will be applied in order to maintain a healthy grass. C. Grass Replanting. At any time slope grass should decrease to less than 40% of the slope soil surface, additional grass seed shall be planted. D. Trash and Debris Removal. Trash, litter and non -planted vegetation will be removed as needed to prevent obstruction to the slow of water, to prevent movement of trash and litter to downstream properties, to maintain the integrity of the structure, and to provide an attractive appearance. E. Non -Routine Maintenance. Minor soil slope erosion, rills and slump areas will be promptly addressed and in a workmanlike manner (areas deemed to be related to slope Instability will be promptly brought to the Owners attention for direction). Pipes, clear well, and pumps will be maintained, repaired and/or replaced as needed to maintain the integrity of the SGI. Security Fence. The Utility shall maintain the security fence around the SGI and insure the access gate is locked at all times when maintenance is not being performed. 4. Utility shall pay the cost of its Maintenance Obligations up to $2,500 per calendar year, and any greater amounts expended for maintenance of the SGI shall be bome by Owner. Should Utility expend more than $2,500 on Maintenance Obligations in any calendar year, Utility shall (a) notify Owner of any costs exceeding the $2,500 for which reimbursement will be sought prior to those costs being incurred, (b) provide Owner with reasonable documentation of such expenditures in excess of $2,500 and (c) Owner shall reimburse Utility for such costs within 30 days of receipt of an invoice. Utility shall perform maintenance inspections of the SGI as often as required by DEQ and otherwise no less than twice a year with Owner and/or with Owners representative, and provide written copies of the maintenance inspection reports to the Owner. These inspections will be performed at reasonable times (between 8:00 A.M. and 5:00 P.M., Monday through Friday). The Utility shall inspect the SGI within 24 hours after each rainfall event of three inches or more of rain in any 24-hour period to monitor water levels and slope condition. The Utility shall keep written records of these inspections and forward copies to the Owner upon request. Article IV Indemnification and Hold Harmless Owner shall save and hold Utility harmless from and against all suits or claims that may be based upon any injury to any person or property that may occur in the course of the performance of the construction or maintenance of the SGI by Owner or by anyone acting on Owners behalf, or under Owners supervision and control, including but not limited to claims made by employees of Owner, and Owner Pond Maintenance Agreement shall, at its own cost and expense, pay all costs and other expenses arising therefrom, or incurred in connection therewith, including reasonable attomeys' fees. 2. Utility shall save and hold Owner harmless from and against all suits or claims that may be based upon any injury to any person or property that may occur in the course of the performance of the Maintenance Obligations by Utility or by anyone acting on Utility's behalf, or under Utility's supervision and control, including but not limited to claims made by employees of Utility, and Utility shall, at its own cost and expense, pay all costs and other expenses arising therefrom, or incurred in connection therewith, including reasonable attorneys' fees. In addition, Utility shall save and hold Owner harmless from and against all suits or claims, costs, expenses, attomey(s)' fees and costs of investigation and clean up including, without limitation, claims, suits and proceedings by Federal, State, County and local governmental authorities with respect to, or as a result of, any prohibited, hazardous, toxic or dangerous substance that is contained in any groundwater provided from the Utility's high rate infiltration basins to Owner's SGI, provided this shall not apply to the extent such issue is caused by the actions of Owner or a third party not affiliated with Utility. 3. The representations, warranties and agreements contained herein shall survive, and continue in effect, after the construction of the SGI. Owner agrees to indemnify Utility, its successors and assigns, and hold it and them harmless against any loss, damage, liability, expense or cost of Utility, accruing or resulting from any misrepresentation or breach of any representation, warranty or agreement on the part of Owner under this Agreement, or from any misrepresentation in or material omission from any certificate or other document furnished or to be furnished to Utility by Owner. Utility agrees to indemnify Owner, its successors and assigns, and hold it and them harmless against any loss, damage, liability, expense or cost of Owner, accruing or resulting from any misrepresentation or breach of any representation, warranty or agreement on the part of Utility under this Agreement, or from any misrepresentation in or material omission from any certificate or other document furnished or to be furnished to Owner by Utility. Article V Insurance 1. Owner and Utility shall each purchase and maintain liability insurance for the duration of this Agreement. All insurance shall be with companies duly licensed or approved to do business in the State of North Carolina with policies and forms satisfactory to both parties. Each insurer shall have a current Best rating of 'V or better. Owner and Utility shall include all sub -consultants and subcontractors providing work as insureds under their respective policies or shall furnish separate certificates of insurance and endorsements for each. All coverages for sub -consultants and subcontractors shall be subject to all of the insurance requirements stated herein. Each party's insurance policies required by this Agreement, except Workers' Compensation, shall name the other party as an additional insured. 2. The insurance required by Article V, paragraph 1 herein shall have limits which are the greater of the limit as required by law or as follows; A. Comprehensive General Liabilitv Insurance - a combined single limit coverage of not less than $1,000,000 per occurrence and $2,000,000 aggregate for products and completed operations and shall include broad form general liability, comprehensive bodily injury, broad form property damage, independent contractors insurance, completed operations and contractual liability insurance for the indemnification provision contained in this Agreement. B. Comorehensive Automobile Liabilii Insurance covering owned, non -owned and hired vehicles with a combined single limit coverage of not less than $1,000,000.00 per occurrence for bodily injury and property damage. 6 Pond Maintenance Agreement C. Workers Compensation and Employers Liabilitv Insurance in compliance with the law or laws of the state or states in which employees are hired or will work with limits of not less than $1,000,000.00 for each accident or occurrence. 3. Owner and Utility hereby release each other and each other's employees, agents, customers, and invitees, from any and all liability for any loss of or damage or injury to person or property in connection with the SGI by reason of fire or other casualty which are insured against under a cause of loss — special form Insurance policy or a standard commercial general liability insurance policy, or which are required to be insured against herein, regardless of cause, including negligence of Owner or Utility and their respective employees, agents, customers and invitees, and agree that such Insurance carried by them shall contain a clause whereby the insurer waives its right of subrogation against the other party. Because the provisions of this paragraph are intended to preclude the assignment of any claim mentioned herein by way of subrogation or otherwise to an insurer or any other person, each party to this Agreement shall give to each insurance company which has issued to it one or more policies notice of the provisions of this paragraph and have such insurance policies properly endorsed, if necessary, to prevent the invalidation of such insurance by reason of the provisions of this paragraph. Within 10 days following execution of this Agreement, each party shall furnish the other party with Certificates of Insurance, or formal endorsements as required by this Agreement, issued by the parties' insurer(s), as evidence that policies providing the required coverages, conditions, and limits required by this Agreement are in full force and effect. Such Certificates and endorsements shall identify this Agreement. Article VI Dispute Resolution 1. In the event of any dispute between Owner and Utility arising out of or relating to this Agreement, or the breach thereof, and/or a claim for monetary damages arising therefrom, the parties agree that the following dispute resolution procedure shall be complied with. A. If a claim or dispute of any nature arises between the parties, both parties first shall exert all reasonable and necessary efforts, amicably and in good faith, to resolve such dispute promptly and with finality, by direct negotiation between the parties. Any settlement agreement shall be placed in writing. B. Should such efforts fail to settle the dispute, then one party shall send to the other a notice in writing, and the receiving party shall have 10 working days to submit a written response. The notice and response shall include: (i) a statement of each party's position and a summary of facts supporting that position, with documentation, and (10 the name and title of the company executive or manager, and that of one other accompanying person, who will represent that party in negotiations. Within 30 working days after delivery of the written response, the representatives from each side shall meet at a mutually acceptable time and place, and thereafter as often as they reasonably deem necessary, to exert their best efforts to resolve the dispute with finality. All reasonable requests for information made by either party to the other shall be honored. Any settlement agreement shall be placed in writing. B. Should negotiations between the representatives not be successful after 30 days of negotiations, the dispute shall then be submitted to mediation administered by the American Arbitration Association, or by another North Carolina certified mediator that the parties agree upon. W Pond Maintenance Agreement C. Should mediation efforts not be successful within 30 days, then the parties agree to submit their dispute to binding arbitration, in accordance with the applicable rules, regulations, and procedures of the American Arbitration Association. The arbitration panel shall be composed of two arbitrators, one of which was appointed by each of the parties to the claim or dispute, and a third independent arbitrator to be appointed by the American Arbitration Association. D. Each of the parties shall bear all of its own expenses in the mediation process and each shall pay one-half of the costs and expenses of the American Arbitration Association in the administration of any mediation. In the event that any claim or conflict arising out of this Agreement is submitted to arbitration, the prevailing party in the arbitration shall be entitled to receive in addition to all other damages to which it may be entitled, the costs incurred by such party in connection with the arbitration proceeding, including reasonable aitomeys' fees and expenses. Article Vll General This Agreement is intended to be performed in the State of North Carolina and shall be governed by the laws of the State of North Carolina. Except as provided for in this Agreement, neither party to this Agreement shall be liable to the other for failure, default or delay in performing any of its obligations hereunder, if such failure, default or delay is caused by strikes or other labor problems, by forces of nature, unavoidable accident, fire, acts of the public enemy, interference by civil authorities, acts or failure to act, decisions or orders or regulations of any governmental or military body or agency, office or commission, delays in receipt of materials, or any other cause, whether of similar or dissimilar nature, not within the control of the party affected and which, by the exercise of due diligence such party is unable to prevent or overcome, except as otherwise provided for herein. Should any of the foregoing events occur, the parties hereto agree to proceed with diligence to do what is reasonable and necessary so that each party may perform its obligations under this Agreement. The failure of either party hereto to enforce any of the provisions of this Agreement, or the waiver thereof in any instance by either party shall not be construed as a general waiver or relinquishment on its part of any such provisions, but the same shall, nevertheless, be and remain in full force and effect. This Agreement sets forth the complete understanding between Owner and Utility, and any amendments hereto to be effective must be made in writing. This Agreement shall continue until Owner and Utility terminate the Agreement in writing. Any notice allowed or required by this Agreement shall be deemed to have been sufficiently served if the same shall be in writing and either sent by nationally recognized overnight courier service or placed in the United States mail, via certified mail or registered mail, return receipt requested, with proper postage prepaid, arid addressed as follows: if to Utility: Pluris Hampstead, LLC Maurice W. Gallarda, PE Manager 2100 McKinney Avenue, Suite 1550 Dallas, Texas 75201 Pond Maintenance Agreement If to Owner: BLAKE FARM POND, LLC Tammy Spivey Development Manager 1202 Eastwood Road Wilmington, North Carolina 28403 Delivery when made by overnight courier or registered or certified mail shall be deemed complete upon mailing, The parties' notice addresses may be changed or added from time to time by either party giving notice to the other in the above -prescribed manner. This Agreement shall be binding upon and inure to the benefit of the parties hereto and their respective successors and assigns. The Exhibits to this Agreement are a part hereof and are hereby incorporated in full by reference. IN WITNESS WHEREOF, the parties hereto have set their hands and seals the day and year above first written. Plurisrampstead, LLC 4 Q Maurice Gallarda, PE Manager q Date: 6 �. Wltne55: l�l�— Print Name Blake Farm Pond, LLC Raiford Trask, Ili Manager Date: /��f Witness: U (All 'lYl. -t rwvly 10 i vc� Print Name 1 9 Pond Maintenance Agreement Exhibit A The SGI will store surplus groundwater resulting from flow of underground groundwater from the Utility's high rate infiltration basins situated on the Utility Property. The SGI shall include inlet pipe, The SGI will be equipped with a clear well and a duplex submersible pumping system to direct surplus groundwater to a surplus groundwater force main for the sole use of the Owner. In addition the SGI will have a hydro pneumatic tank to assure a reasonable pressure gradient in the force main and to avoid water hammer in the distribution system. A drawing depicting the planned structure of the SGI is presented as Exhibit A-1, immediately following this page. 10 Exhibit A-1 Depiction of SGI (See attached) Pond Maintenance Agreement 11 Pond Maintenance Agreement Exhibit B Owners Property That certain Tract "C' 10.14 acres as shown on preliminary plat attached. 12