Loading...
HomeMy WebLinkAboutNC0083941_Fact Sheet_20240718Docusign Envelope ID: B7F5B167-EF68-48BC-AC69-786689E46FF3 NCDEQ / DWR / NPDES EXPEDITED FACT SHEET - NPDES PERMIT RENEWAL NPDES Permit NCO083941 Catherine Shadwell, Compliance & Expedited Permitting Unit / 919-707-3613 March 2024 FACILITY INFORMATION Applicant/Facility Name Aqua North Carolina, Inc. (Lauren Raup-Plummer) Spring Creek WWTP Applicant Mailing Address 202 MacKenan Court Cary NC 27511 Facility Physical Address Central Rd Clemmons NC 27012 Permitted Flow (MGD) 0.08 MGD Type of Waste 100% Domestic, < 1 MGD Facility Class WW-2 County vidson Permit Status Renewal Regional Office+Da SRO STREAM CHARACTERISTICS Receiving Stream Fryes Creek Stream Classification C Stream Segment 12-94-15 Outfall Lat. 350 58' 37" N 7Q10 - Summer (cfs) 0.64 Outfall Long. 800 18' 10.1" W 7Q10 - Winter (cfs) 1.59 Drainage basin Yadkin -Pee Dee 30Q2 (cfs) 2.03 Subbasin 03-07-04 Average Flow (cfs) 8.93 HUC 030401011308 IWC (%) 16.23% (summer) / 7.23% (winter) 303(d) List Not listed. BASIC INFO FOR EXPEDITED PERMIT RENEWAL Does permit need Daily Max NH3 limits? Already present in permit Does permit need TRC limits/footnote? Already present in permit (Does permit have toxicity testing? No Does permit have any Special Conditions? Yes, nutrient reopener for high rock lake. Does permit have instream monitoring? No New expiration date: May 31, 2029 Facility Summary Aqua North Carolina, Inc. Operates a small wastewater treatment plant for Spring Creek Subdivision. Spring Creek WWTP treats 100% domestic wastewater. This facility is a minor facility (flow < 1 MGD) with a design capacity and permitted wastewater discharge of 0.08 MGD. The WWTP was originally permitted in 1994. This facility utilizes the following treatment components: • Bar screen • Flow equalization basins • Dual aeration basins • Dual Secondary clarifiers • UV Disinfection • Back up chlorination and de -chlorination • Single aerated sludge digesters • Effluent flow meter and weir • Emergency generator • Post aeration Fact Sheet for Permit Renewal April 2024 - NPDES Permit NCO083941 - Page 1 Docusign Envelope ID: B7F5B167-EF68-48BC-AC69-786689E46FF3 Renewal Summary This renewal contains the following changes: • Updated Section A. (3.) to reflect current federal requirements for Electronic Reporting of Discharge Monitoring Reports. • Updated Outfall map • Added new winter ammonia nitrogen limits to be in compliance with 2B .0404(c) - Winter Limits can be no less stringent than 2 times the summer limits. New limits will go into effect January 1, 2029. • Updated Total Nitrogen to include TKN and NO3-N + NO2-N as well as updated Total Nitrogen's monitoring requirements. This was done to account for all components of Total Nitrogen for the monitoring reports. Compliance History In the past 5 years, this facility has received 1 NOV in 2024 for violations detected during a compliance inspection. Inspection found that facility was monitoring flow rates at a constant rate instead of permitted requirement of composite sampling. Comments on Draft Permit Fact Sheet for Permit Renewal April 2024 - NPDES Permit NC0083941 - Page 2 Docusign Envelope ID: B7F5B167-EF68-48BC-AC69-786689E46FF3 IWC Calculations Facility:Spring Creek WWTP Permit No.: NC0083941 Prepared By: Catherine Shadwell Enter Design Flow (MGD): 0.08 <= Permitted Flow if Different from Design Enter s7Q10 (cfs): 0.64 Enter w7Q10 (cfs): 1.59 Total Residual Chlorine (TRC) Ammonia (Summer) Daily Maximum Limit (ug/1) Monthly Average Limit (mg NH3-N/1) Design Permitted Design Permitted s7Q10 (CFS) 0.64 s7Q10 (CFS) 0.64 DESIGN FLOW (MGD) 0.08 DESIGN FLOW (MGD) 0.08 € DESIGN FLOW (CFS) 0.124 DESIGN FLOW (CFS) 0.124 STREAM STD (UG/L) 17.0 STREAM STD (MG/L) 1.0 Upstream Bkgd (ug/1) 0 Upstream Bkgd (mg/1) 0.22 IWC (%) 16.23 IWC (%) 16.23 Allowable Conc. (ug/1) 105 Allowable Conc. (mg/1) 5.0 Ammonia (Winter) Monthly Average Limit (mg NH3-N/1) Design Permitted Design Permitted Fecal Coliform w7Q10 (CFS) 1.59 Monthly Average Limit: 200/100ml € #VALUE! DESIGN FLOW (MGD) 0.08 (If DF >331; Monitor) DESIGN FLOW (CFS) 0.124 (If DF<331; Limit) STREAM STD (MG/L) 1.8 Dilution Factor (DF) 6.16 #VALUE! Upstream Bkgd (mg/1) 0.22 IWC (%) 7.23 Allowable Conc. (mg/1) 22.1 *2B .0404 (c) Applies Total Residual Chlorine 1. Cap Daily Max limit at 28 ug/I to protect for acute toxicity Ammonia (as NH3-N) 1. If Allowable Conc > 35 mg/l, Monitor Only 2. Monthly Avg limit x 3 = Weekly Avg limit (Municipals) 3. Monthly Avg limit x 5 = Daily Max limit (Non-Munis) If the allowable ammonia concentration is > 35 mg/L, no limit shall be imposed By Policy dischargers < 1 MGD get limits no lower than 2 & 4 due to BAT * From 2B .0404(c) - Winter Limits can be no less stringent than 2 times the summer limits Fecal Coliform 1. Monthly Avg limit x 2 = 400/100 ml = Weekly Avg limit (Municipals) = Daily Max limit (Non -Muni) Docusign Envelope ID: B7F5B167-EF68-48BC-AC69-786689E46FF3 70097050 70939845 AFFIDAVIT OF PUBLICATION STATE OF NORTH CAROLINA LEXINGTON, NC April 18, 2024 DAVIDSON COUNTY I, Lynn Bowers OF THE DISPATCH, A NEWSPAPER PUBLISHED IN THE CITY OF LEXINGTON, COUNTY AND STATE AFORESAID, BEING DULY SWORN, SAYS THE FOREGOING LEGAL OF WHICH THE ATTACHED IS A TRUE COPY, WAS PUBLISHED IN SAID NEWSPAPER ONCE A WEEK FOR 1 WEEK, BEGINNING THE 18th DAY OF April, 2024 PUBLICATION FEE: $ 99.55 O)qam (SEAL) SWORN TO AND SUBSCRIBED BEFORE ME, THIS I r+-h- DAY OF MY COMMISSION EXPIRES _/►-ed-L_f �;. BLS •�. Ad Copy: Cou Ili I k WI Public Notice North Carolina Environmental Management Commission/NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Notice of Intent to Issue a NPDES Wastewater Permit NCO083941 Spring Creek WWTP The North Carolina Environmental Management Commission proposes to issue a NPDES wastewater discharge permit to the person(s) listed below. Written comments regarding the proposed permit will be accepted until 30 days after the publish date of this notice. The Director of the NC Division of Water Resources (DWR) may hold a public hearing should there be a significant degree of public interest. Please mail comments and/or information requests to DWR at the above address. Interested persons may visit the DWR at 512 N. Salisbury Street, Raleigh, NC 27604 to review the information on file. Additional information on NPDES permits and this notice may be found on our website: hips://deq.nc.aov/public-notices-hear*nas, or by calling (919) 707-3601. Aqua North Carolina, Inc. [202 MacKenan Court, Cary, NC 275111 has applied for renewal of NPDES Permit NCO083941 for the Spring Creek WWTP in Davidson County. This permitted facility discharges treated domestic wastewater to Fryes Creek in the Yadkin - Pee Dee River Basin. Currently, BOD and ammonia nitrogen are water quality limited. This discharge may affect future allocations in this portion of the watershed. April 18, 2024