Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0056961_Fact Sheet_20240713
NCDEQ / DWR EXPEDITED FACT SHEET - NPDES PERMIT RENEWAL NPDES Permit NCO056961 / NCG590039 Sydney Deuterman / Compliance & Expedited Permitting Unit / sydney.deutermangdeq.nc.gov / June 2024 FACILITY INFORMATION Facility Name DeBruhl Water Treatment Plant Applicant Name City of Asheville / Attn: Debra Campbell, City Manager Applicant Contact Email bcooWashevillenc.gov / bhartgashevillenc.gov / jbledsoenashevillenc.gov / mringgenberg(kashevillenc.gov Applicant Mailing Address 3374 N Fork — Left Fork Rd, Black Mountain, NC 28711 Facility Physical Address 1370 Bee Tree Road, Swannanoa, NC 28778 Max, Monthly Avg Flow (MGD) 0.157 MGD Permitted Flow (Max Monthly 0.18 MGD Average Flow + 15% Buffer) Type of Waste Filter backwash and decant from lagoons Facility Class PC-1 County Buncombe Renewal/Transfer to Permit Status NCG59 General Regional Office ARO Permit STREAM CHARACTERISTICS Receiving Stream Beetree Creek Stream C Classification Stream Segment 6-78-15-(6) Outfall 350 38' 26.2" N Coordinates 820 23' 57.8" W 7Q 10 — Summer/Winter (cfs) 0.71 / 1.25 Drainage basin French Broad 30Q2 (cfs) 1.84 Subbasin 04-03-02 Average Flow (cfs) -- HUC 060101050603 IWC (%) SUM/Win 29% 303(d) List Not Impaired FACILITY OVERVIEW William DeBruhl WTP is a conventional water treatment plant with a design potable flowrate of 5.2 MGD. The maximum, monthly average flow over the past three years (May 2021 through April 2024) is 0.157 MGD. The treatment process consists of filtration with pre -chlorine and Poly Aluminum Chloride (PAC) added to the raw water. The water is then treated with fluoride, zinc orthophosphate, sodium bicarbonate, and caustic before the clearwell. Backwash water from the filters is sent to a 500,000-gallon primary lagoon and a 300,000-gallon secondary lagoon where the solids are settled out and the supernatant discharged. Settled sludge that has accumulated is pumped out and hauled away for disposal. The existing treatment components at the water treatment plant are the following: • Filtration • 500,000-gallon lagoon • 300,000-gallon lagoon • Clearwell Chemical usage consists of: • Poly aluminum chloride (PAC) • Sodium bicarbonate Sodium hydroxide Sodium hypochlorite Zinc orthophosphate Fact Sheet for Permit Renewal Jun 2024 - NPDES Permit NC0056961/NCG590039 - Page 1 • Chlorine • Fluoride APPLICATION NOTES The City of Asheville is requesting a transfer of coverage from an individual permit to the NCG590000 General Permit. The old WTP application, Short Form C, was submitted for this facility in September 2021. As of 2022, permittees are required to complete and submit EPA's application forms in place of North Carolina's old ones. As the application was submitted before this change became mandated and significant time has passed between application and processing of the renewal/transfer, we will not require the re -submittal using EPA's forms and will proceed with what has been received. RENEWAL SUMMARY The City has requested to move to the NCG590000 General Permit. Based on the general permit's requirements, they are eligible for coverage and will be switching over. The new permit number is NCG590039. The individual permit (NC0056961) will be rescinded. MONITORING DATA REVIEW The eDMR data reviewed for this renewal is from November 2019 through April 2024. Parameters (Effluent) Units Minimum Maximum Average Count 00070 - Turbidity NTU 0.55 19.60 2.15 186 00400 - pH Su 4.90 7.90 7.13 199 00900 - Hardness, Total (as CaCO3) mg/L 5.00 22.00 8.01 36 00951 - Fluoride, Total (as F) mg/L 0.10 0.70 0.15 18 01042 - Copper, Total (as Cu) mg/L 0.00 0.00 0.00 18 01092 - Zinc, Total (as Zn) mg/L 0.00 0.02 0.01 18 01105 - Aluminum, Total (as Al) mg/L 0.06 0.70 0.26 18 50050 - Flow, in conduit or thru treatment plant MGD 0.05 79.80 0.16 1158 50060 - Chlorine, Total Residual Ug/L 20.00 58.00 20.74 199 C0530 - Solids, Total Suspended - Concentration mg/L 2.50 66.00 5.58 183 COMPLIANCE HISTORY DeBruhl WTP has no enforcements on record since the permit was originally issued in 1984. The most recent compliance evaluation inspection (June 2021) showed the facility to be in compliance, however the inspection summary notes that there have been several incidents involving the chemical tank farm in recent years and that an evaluation of all structures and plumbing needs to be performed to identify necessary improvements. They also strongly recommend that the tank farm be covered/enclosed to protect the structures and mitigate incidents. Only three NOVs have been issued during the past permit cycle for pH, TRC, and TSS. NCG59 GENERAL PERMIT ELIGIBILITY • Conventional treatment technology - eligible • They've passed > 75% of TOX tests within the last 4 years - eligible • They've passed all of the last four TOX tests - eligible • No metal limits required - eligible Conclusion: Eligible for NCG59 General Permit Fact Sheet for Permit Renewal Jun 2024 - NPDES Permit NC0056961/NCG590039 - Page 2 WHOLE EFFLUENT TOXICITY (WET) TESTING In accordance with current strategies designating this facility as a conventional water treatment plant, WET testing is required in this permit as freshwater Chronic [TGP3B] Pass/Fail Quarterly monitoring with Ceriodaphnia dubia at an effluent concentration of 29%. This facility has passed all toxicity tests from Jan 2020 through April 2024. REASONABLE POTENTIAL ANALYSIS (RPA) The need for toxicant limits is based upon a demonstration of reasonable potential to exceed water quality standards, a statistical evaluation that is conducted during every permit renewal utilizing the most recent effluent data for each outfall. The RPA is conducted in accordance with 40 CFR 122.44 (d) (i). The NC RPA procedure utilizes the following: 1) 95% Confidence Level/95% Probability; 2) assumption of zero background; 3) use of detection limit for "less than" values; and 4) streamflows used for dilution consideration based on 15A NCAC 213.0206. Effective April 6, 2016, NC began implementation of dissolved metals criteria in the RPA process in accordance with guidance titled NPDES Implementation of Instream Dissolved Metals Standards, dated June 10, 2016. A reasonable potential analysis (RPA) was conducted on effluent data collected between November 2019 — April 2024. Per the new guidance for water treatment plants, a flow (Qw) of 0.18 MGD was used. This flow is based on the maximum, monthly average flow during the past three years (0.157 MGD), with a 15% reserve capacity added and rounded to two significant figures. Based on this analysis, the following permitting actions are proposed for this permit: • Copper, Fluoride, Zinc — no reasonable potential to exceed water quality standards; predicted max < 50% of allowable concentration; monitoring being maintained for Fluoride and Zinc as the facility indicated these pollutants have the potential to be discharged. Fact Sheet for Permit Renewal Jun 2024 - NPDES Permit NC0056961/NCG590039 - Page 3 Whole Effluent Toxicity Testing and Self Monitoring Summary Asheville DeBruhl WTP NCO056961/001 County: Buncombe Ceri7dPF Begin: 4/11/2017 chr monit: 29% (Grab NonComp: Single J F M A M 2020 Pass - - Pass - 2021 Pass - - Pass - 2022 Pass - - Pass - 2023 Pass - - Pass - 2024 Pass - - Pass - Asheville Northfork WTP NCO035807/001 County: Buncombe Ceri7dPF Begin: 4/1/2017 chr Monit: 22% NonComp: Single J F M A M 2020 Pass - - Pass - 2021 Pass - - Pass - 2022 Pass - - Pass - 2023 Pass - - Pass - 2024 Pass - - Pass - Asheville Steam Electric Plant-001 NC0000396/001 County: Buncombe Ceri7dPF Begin: 12/1/2018 chr lim: 1.8% NonComp: Single J F M A M 2020 Pass Pass Pass Pass Pass 2021 Pass Pass Pass Pass Pass 2022 Pass Pass Pass Pass Pass 2023 Pass Pass Pass Pass Pass 2024 Pass Pass Pass Pass - Associated Asphalt Greensboro (HRS) NCO074241/001 County: Guilford Fthd24PF Begin: 11/1/2021 24hr static ac monit a NonComp: J F M A M 2020 >100 - 2021 - >100 - 2022 >100 >100 2023 - >100 - - >100 2024 - >100 - - >100 Atlantic Beach WTP NCO044806/001 County: Carteret Mysd24PF Begin: 11/1/2020 Ac P/F Monit: 90% M NonComp: J F M A M 2020 Fail - - Fail - 2021 Pass - - Pass - 2022 Pass - - Fail - 2023 Pass - - Pass - 2024 Pass - - Pass - Region: ARO Basin: FRB02 Jan Apr Jul Oct SOC JOC: 7Q10: 1.1 PF: 0.1 IWC: 12.3 Freq: Q J J A S O N Pass - - Pass Pass - - Pass Pass - - Pass Pass - - Pass Region: ARO Basin: FRB02 Jan Apr Jul Oct SOC JOC: 7Q10: 1.7 PF: 0.8 IWC: 42.2 Freq: Q J J A S O N Pass - - Pass - Pass - - Pass Pass - - Pass Pass - - Fail Region: ARO 7Q10: 375.0 J Pass Pass Pass Pass J Pass Pass Pass Pass Basin: PF: NA FRB02 IWC: A Pass Pass Pass Pass Jan Apr Jul Oct NA Freq: M S Pass Pass Pass Pass O Pass Pass Pass Pass SOC JOC: N Pass Pass Pass Pass Region: WSRO Basin: CPF08 Feb May Aug Nov SOC JOC: 7Q10: 0.0 PF: VAR IWC: 100 Freq: Q J J A S O N - >100 H - - >100 - >100 H Region: WIRO Basin: WOK03 Jan Apr Jul Oct SOC JOC: 7Q10: PF: NA IWC: Freq: Q I I A S O N - Fail - - Fail - - Fail - - Fail - - Fail - - Fail - - Pass - - Fail - C C D Pass Pass Pass Pass C C Leeend: P= Fathead minnow (Pimohales oromelas). H=No Flow (facilitv is active). s = Solit test between Certified Labs Page 5 of 113 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM DATA POINTS = 58 REQUIRED DATA ENTRY Table 1. Project Information ❑ CHECK IF HQW OR ORW WQS Facility Name WWTP/WTP Class NPDES Permit Outfal I Flow, Qw (MGD) Receiving Stream HUC Number Stream Class DeBruhl WTP PC-1 NCO056961 001 0.181 Beetree Creek 060101050603 C ❑ Apply WS Hardness WQC Lentic or Lotic 7Q10s (cfs) 7Q10w (cfs) 30Q2 (cfs) QA (cfs) 1 Q10s (cfs) 0.71 1.25 1.84 0.00 0.60 Effluent Hardness Upstream Hardness - - - - - - - - - - - - - Combined Hardness Chronic Combined Hardness Acute 6.52 mg/L (Avg) 7.56 mg/L (Avg) - - - - - - - - - - - - - - - - - - - - - - 25 mg/L 25 mg/L Data Source(s) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ BINIS StreamfI7A data and DMR data from 2-019- 2024. This facility is aplying for coverage under the NCG59 General Permit (Application # NCG590039) ❑ CHECK TO APPLY MODEL Par01 Par02 Par03 Par04 Par05 Par06E Par07 Par08 Par09 Par10 Par11 Par12 Par13 Par14 Par15 Par16 Par17 Par18 Par19 Par20 Par21 Par22 Par23 Par24 Par25 Table 2. Parameters of Concern Name WQs Type Chronic Modifier Acute PQL Units Arsenic Aquactic Life C 150 FW 340 ug/L Arsenic Human Health Water Supply C 10 HH/WS N/A ug/L Beryllium Aquatic Life NC 6.5 FW 65 ug/L Cadmium Trout NC 1.0015 TR 1.9412 ug/L Chlorides Aquatic Life NC 230 FW mg/L Chlorinated Phenolic Compounds Water Supply NC 1 A ug/L Total Phenolic Compounds Aquatic Life NC 300 A ug/L Chromium III Aquatic Life NC 117.7325 FW 905.0818 ug/L Chromium VI Aquatic Life NC 11 FW 16 lag/L Chromium, Total Aquatic Life NC N/A FW N/A lag/L Copper Aquatic Life NC 7.8806 FW 10.4720 ug/L Cyanide Aquatic Life NC 5 FW 22 10 ug/L Fluoride Aquatic Life NC 1,800 FW ug/L Lead Aquatic Life NC 2.9416 FW 75.4871 ug/L Mercury Aquatic Life NC 12 FW 0.5 ng/L Molybdenum Human Health NC 2000 HH ug/L Nickel Aquatic Life NC 37.2313 FW 335.2087 lag/L Nickel Water Supply NC 25.0000 WS N/A lag/L Selenium Aquatic Life NC 3.1 FW 56 ug/L Silver Aquatic Life NC 0.06 FW 0.2964 ug/L Zinc Aquatic Life NC 126.7335 FW 125.7052 ug/L 56961 FW RPA 2024, input 6/6/2024 DeBruhl WTP Outfall 001 NCO056961 Freshwater RPA - 95% Probability/95% Confidence Using Metal Translators MAXIMUM DATA POINTS = 58 Qw (MGD) = 0.1810 1Ql0S (cfs) = 0.60 7Q10S (cfs) = 0.71 7Q10W (cfs) = 1.25 30Q2 (cfs) = 1.84 Avg. Stream Flow, QA (cfs) = 0.00 Receiving Stream: Beetree Creek HUC 060101050603 WWTP/WTP Class: PC-1 IWC% @ 1Q10S = 31.86076884 IWC% @ 7Q10S = 28.32264903 IWC% @ 7Q10W = 18.33001209 IWC% @ 30Q2 = 13.23005824 IW%C @ QA = 100 Stream Class: C Qw = 0.181 MGD COMBINED HARDNESS (mg/L) Acute = 25 mg/L Chronic = 25 mg/L PARAMETER NC STANDARDS OR EPA CRITERIA Cl)REASONABLE POTENTIAL RESULTS RECOMMENDED ACTION TYPE J Applied Chronic Acute0. n # Det. Max Pred Cw Allowable Cw Standard Acute: 32.87 No RP, Predicted Max < 50% of Allowable Cw - No Copper NC 7.8806 FW(7Q10s) 10.4720 ug/L 18 2 6.78 Monitoring required Chronic: 27.82 No RP, Predicted Max < 50% of Allowable Cw - No No value > Allowable Cw Monitoring required Acute: NO WQS Fluoride NC 1800 FW(7Q10s) ug/L 18 10 1,267.0 ------------------------------------------------ Chronic: 6,355.3 No RP, Predicted Max < 50% of Allowable Cw - No No value > Allowable Cw Monitoring required Acute: 394.5 No RP, Predicted Max < 50% of Allowable Cw - No Zinc NC 126.7335 FW(7Q10s) 125.7052 ug/L 18 4 32.4 Monitoring required ------------------------------------------------ Chronic: 447.5 No RP, Predicted Max < 50% of Allowable Cw - No No value > Allowable Cw Monitoring required Acute: 0 0 N/A —_ _ -Chronic:----------- --------------------------- Acute: 0 0 N/A —_ _ ------------ Chronic: --------------------------- Acute: 0 0 N/A —_ _ -Chronic:----------- --------------------------- Acute: 0 0 N/A --Chronic:----------- --------------------------- 56961 FW RPA 2024, rpa Page 2 of 2 6/6/2024 REASONABLE POTENTIAL ANALYSIS H1 I Effluent Hardness I Date Data 1 1 /7/2020 2 4/14/2020 < 3 7/14/2020 < 4 10/13/2020 < 5 1 /12/2021 6 4/13/2021 < 7 7/20/2021 8 10/12/2021 9 1 /11 /2022 10 4/12/2022 11 7/5/2022 12 10/11 /2022 13 1 /17/2023 14 4/11/2023 15 7/18/2023 < 16 10/10/2023 17 1 /2/2024 < 18 4/2/2024 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 BDL=1/2DL Results 8 8 Std Dev. 5 2.5 Mean 5 2.5 C.V. 5 2.5 n 6.1 6.1 10th Per value 5 2.5 Average Value 6 6 Max. Value 12 12 14 14 6 6 6.1 6.1 10 10 6 6 8.1 8.1 5 2.5 10 10 5 2.5 10 10 Use "PASTE SPECIAL Values" then "COPY" Maximum data points = 58 3.6390 6.5167 0.5584 18 2.50 mg/L 6.52 mg/L 14.00 mg/L H2 Date Data 1 1 /7/2020 2 4/14/2020 < 3 7/14/2020 4 10/13/2020 < 5 1 /12/2021 < 6 4/13/2021 < 7 7/20/2021 8 10/12/2021 9 1 /11 /2022 10 4/12/2022 11 7/5/2022 < 12 10/11/2022 < 13 1 /17/2023 14 4/11 /2023 < 15 7/18/2023 16 10/10/2023 17 1 /2/2024 18 4/2/2024 < 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Upstream Hardness BDL=1/2DL Results 6 6 Std Dev. 5 2.5 Mean 8 8 C.V. 5 2.5 n 5 2.5 10th Per value 5 2.5 Average Value 8 8 Max. Value 16 16 16 16 8 8 5 2.5 5 2.5 10 10 5 2.5 22 22 16 16 6.1 6.1 5 2.5 Use "PASTE SPECIAL Values" then "COPY" Maximum data points = 58 6.1268 7.5611 0.8103 18 2.50 mg/L 7.56 mg/L 22.00 mg/L 56961 FW RPA 2024, data - 1 - 6/6/2024 REASONABLE POTENTIAL ANALYSIS Pal Date Data 1 1 /7/2020 < 2 4/14/2020 < 3 7/14/2020 < 4 10/13/2020 < 5 1/12/2021 < 6 4/13/2021 < 7 7/20/2021 < 8 10/12/2021 < 9 1/11/2022 < 10 4/12/2022 < 11 7/5/2022 < 12 10/11 /2022 < 13 1/17/2023 < 14 4/11/2023 < 15 7/18/2023 < 16 10/10/2023 17 1 /2/2024 < 18 4/2/2024 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Copper BDL=1/2DL Results 2 1 Std Dev. 2 1 Mean 2 1 C.V. 2 1 n 2 1 2 1 Mult Factor = 2 1 Max. Value 1 0.5 Max. Pred Cw 1 0.5 1 0.5 1 0.5 1 0.5 1 0.5 1 0.5 1 0.5 4.11 4.11 1 0.5 3.34 3.34 Par13 Use "PASTE SPECIAL Values" then "COPY" Maximum data points = 58 1.0102 1.0528 0.9595 18 1.65 4.11 ug/L 6.78 ug/L Fluoride Date Data BDL=1/2DL Results 1 1 /7/2020 130 130 Std Dev. 2 4/14/2020 110 110 Mean 3 7/14/2020 120 120 C.V. 4 10/13/2020 100 100 n 5 1 /12/2021 < 100 50 6 4/13/2021 150 150 Mult Factor = 7 7/20/2021 110 110 Max. Value 8 10/12/2021 200 200 Max. Pred Cw 9 1 /11 /2022 < 100 50 10 4/12/2022 100 100 11 7/5/2022 700 700 12 10/11/2022 < 100 50 13 1 /17/2023 < 100 50 14 4/11 /2023 < 100 50 15 7/18/2023 < 100 50 16 10/10/2023 < 100 50 17 1 /2/2024 < 100 50 18 4/2/2024 100 100 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Use "PASTE SPECIAL Values" then "COPY" Maximum data points = 58 150.3330 123.3333 1.2189 18 1.81 700.0 ug/L 1267.0 ug/L -2- 56961 FW RPA 2024, data 6/6/2024 REASONABLE POTENTIAL ANALYSIS Par21 Date Data 1 1 /7/2020 < 2 4/14/2020 < 3 7/14/2020 < 4 10/13/2020 < 5 1/12/2021 < 6 4/13/2021 < 7 7/20/2021 < 8 10/12/2021 < 9 1/11/2022 < 10 4/12/2022 < 11 7/5/2022 < 12 10/11 /2022 < 13 1 /17/2023 14 4/11/2023 < 15 7/18/2023 < 16 10/10/2023 17 1 /2/2024 18 4/2/2024 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 Use "PASTE SPECIAL Zinc Values" then "COPY" Maximum data points = 58 BDL=1/2DL Results 10 5 Std Dev. 4.0971 10 5 Mean 4.8117 10 5 C.V. 0.8515 10 5 n 18 10 5 10 5 Mult Factor = 1.58 10 5 Max. Value 20.5 ug/L 5 2.5 Max. Pred Cw 32.4 ug/L 10 5 5 2.5 5 2.5 5 2.5 5 5 5 2.5 5 2.5 2.47 2.47 3.64 3.64 20.5 20.5 -3- 56961 FW RPA 2024, data 6/6/2024 NC0056961 NCG590039 Flow Limit Calc 2024 Average Flow Month/Year (MGD) May 2021 0.0758625 Maximum Monthly Avg Flow (3-years): 0.157317 MGD Jun 2021 0.075215789 15% Reserve Capacity: 0.023598 MGD Jul 2021 0.06754375 Flow Limit: 0.181 MGD Aug 2021 0.06877 Sep 2021 0.077785714 Oct 2021 0.06756 Nov 2021 0.077976923 Dec 2021 0.070855 Jan 2022 0.0784 Feb 2022 0.0675375 Mar 2022 0.06755 Apr 2022 0.074330769 May 2022 0.07105 Jun 2022 0.069257895 J u 1 2022 0.06784 Aug 2022 0.072842105 Sep 2022 0.098404348 Oct 2022 0.116009677 Nov 2022 0.13919 Dec 2022 0.079964516 Jan 2023 0.0848 Feb 2023 0.071919048 Mar 2023 0.069028571 Apr 2023 0.071942857 May 2023 0.066473333 Jun 2023 0.06536 Ju12023 0.075062069 Aug 2023 0.075993548 Sep 2023 0.096240741 Oct 2023 0.136087097 Nov 2023 0.157316667 Dec 2023 0.130648387 Jan 2024 0.095907692 Feb 2024 0.085821053 Mar 2024 0.072963158 Apr 2024 0.083644444 6/6/2024 7/17/24, 3:21 PM [External] Re: Permit Issuance for DeBruhl WTP (NCG590039) - Deuterman, Sydney - Outlook [External] Re: Permit Issuance for DeBruhl WTP (NCG590039) Bill Hart <bhart@ashevillenc.gov> Wed 7/17/2024 1:20 PM To:Deuterman, Sydney <sydney.deuterman@deq.nc.gov> Cc:Jud Bledsoe <jbledsoe@ashevillenc.gov>;Brenna Cook <bcook@ashevillenc.gov>;Myrriah Ringgenberg <mringgenberg@ashevillenc.gov> CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Sydney, We acknowledge that we have received: • General Permit NCG90000 Dated August 1, 2019 - July 31, 2024 • Technical Bulletin: General Permit NCG900000 • Certificate of Coverage: Issued under NCG590039 We have successfully opened these documents and will save hard copies and electronic copies for our records Thank you, Bill On Wed, Jul 17, 2024 at 12:07 PM Deuterman, Sydney <sydney.deuterman@deq.nc.gov> wrote: Hello Mr. Hart, A Certificate of Coverage under General Permit NCG590000 has been issued for the DeBruhl WTP. Please respond to this email confirming that you received the attached document(s), were able to open and view the document(s) and have saved/printed a copy for your records. If you have any questions or concerns, please let me know. Thanks, Sydney Deuterman (she/her) Environmental Specialist II Compliance and Expedited Permitting Unit Division of Water Resources N.C. Department of Environmental Quality Office: 919-707-3712 5 dney.deuterman@deg.nc.gov 1617 Mail Service Center Raleigh, NC 27699-1617 ra From: Bill Hart <bhart(@ashevillenc.gov> Sent: Friday, July 12, 2024 3:20 PM To: Deuterman, Sydney <sydney.deuterman(@deq.nc.gov> Cc: Jud Bledsoe <jbledsoe(@ashevillenc.gov>; Brenna Cook <bcook(cDashevillenc.gov>; Myrriah Ringgenberg <mringgenberg(@ashevillenc.gov> Subject: Re: [External] Re: Permit Renewal for DeBruhl WTP (NC0056961 / NCG590039) CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Sydney, as Jud Bledsoe indicated, the City of Asheville is agreeable to the use of electronic transmittal for our correspondence. Thank you, Bill about: blank?windowld=SecondaryReadingPane6 1/5 7/17/24, 3:21 PM [External] Re: Permit Issuance for DeBruhl WTP (NCG590039) - Deuterman, Sydney - Outlook On Wed, Jul 10, 2024 at 4:30 PM Deuterman, Sydney <ss dnev.deuterrnan@deq.nc.gov> wrote: Hello, In order to provide more convenience, control, and security to our permittees and assist them in processing their transactions, The Division of Water Resources is currently transitioning towards electronic correspondence. This will hopefully provide more efficient service to our permittees and other partners and will allow us to more effectively process and track documents. We are writing to ask you for your approval of the transmittal of documents related to your permitting and related activities with the Division in an electronic format. Documents will be emailed to the appropriate contact person(s) in your organization in a PDF format. Please respond to me through email with verification that transmittal of your documents in an electronic manner is acceptable to you. Thanks, Sydney Deuterman (she/her) Environmental Specialist II Compliance and Expedited Permitting Unit Division of Water Resources N.C. Department of Environmental Quality Office: 919-707-3712 Sydney. deuterman@deq.nc.gov 1617 Mail Service Center Raleigh, NC 27699-1617 PA From: Deuterman, Sydney <sydney.deuterman@daeq.nc.gov> Sent: Thursday, June 6, 2024 4:07 PM To: Jud Bledsoe <jbledsoe@ashevillenc.gov>; Brenna Cook <bcook ashevillenc.gov> Cc: Bill Hart <bhart@ashevillenc.gov>; Myrriah Ringgenberg <mringgenberg@ashevillenc.gov> Subject: Re: [External] Re: Permit Renewal for DeBruhl WTP (NC0056961 / NCG590039) Hi Jud, Thanks for your quick response and for providing those sheets! I will continue processing the renewal/transfer for this facility and will reach out if I have any more questions or concerns. Best, Sydney Deuterman (she/her) Environmental Specialist II Compliance and Expedited Permitting Unit Division of Water Resources N.C. Department of Environmental Quality Office: 919-707-3712 Sydney. deuterman@deg.nc.gov 1617 Mail Service Center Raleigh, NC 27699-1617 about: blank?windowld=SecondaryReadingPane6 2/5 7/17/24, 3:21 PM [External] Re: Permit Issuance for DeBruhl WTP (NCG590039) - Deuterman, Sydney - Outlook From: Jud Bledsoe <jbledsoe@ashevillenc.gov> Sent: Thursday, June 6, 2024 3:57 PM To: Brenna Cook <bcook ashevillenc.gov> Cc: Bill Hart <bhart ashevillenc.gov>; Myrriah Ringgenberg <mringgenberg@ashevillenc.gov>; Deuterman, Sydney <sydney.deuterman@deq.nc.gov> Subject: [External] Re: Permit Renewal for DeBruhl WTP (NC0056961 / NCG590039) CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Sydney, I am looking at the records sheet now and it appears that all the data entry is off by a decimal point for all of February and also, July 3. 1 will go in and revise the report and have attached the bench sheets we use to track filter backwashes and volume of water used per filter each day in thousand gallon units(kgal). I must have overlooked the mistakes when I certified the reports. I will be sure to pay attention to this parameter moving forward. Thank you Sydney for bringing this to our attention. Please let me know if you have any questions or concerns. Regards, Jud On Thu, Jun 6, 2024 at 2:03 PM Brenna Cook <bcook@ashevillenc.gov> wrote: Hey Myrriah and Bill, Please see the email below about the wastewater permit renewal. Looks like data may have been entered incorrectly for Feb 2022 for the flow at Bee Tree. Please review and let Sydney with the State know. Sydney is copied on this email. Thanks Brenna ---------- Forwarded message --------- From: Deuterman, Sydney <sydney.deuterman@deq.nc.gov> Date: Thu, Jun 6, 2024 at 1:26PM Subject: Permit Renewal for DeBruhl WTP (NC0056961 / NCG590039) To: bcook@ashevillenc.gov <bcook@ashevillenc.gov>,jbledsoe@ashevillenc.gov <jbledsoe@ashevillenc.gov> Hello, I am the permit writer assigned to this renewal. I apologize for the time it has taken for us to get to this renewal/transfer of coverage request. We have had a number of issues that have led to a backlog of renewals for our staff. I am currently in the process of reviewing your application and the criteria for the NCG590000 General Permit to see if your facility is eligible. Upon reviewing the flow data for this facility, I noticed inconsistencies in the daily flow reported for the month of February 2022. Every daily flow value reported in the month of February 2022 is between 0.683 MGD and 0.665 MGD. These numbers are significantly higher than the other daily flow values reported over the past 3-year period (minimum flow of 0.0503 MGD to a maximum of 0.2751 MGD). Similarly, a value of 0.679 MGD was reported for July 3, 2022. Please review the following flow numbers for February 2022 and July 3, 2022, and confirm if these numbers are indeed accurate. We use flow data from the past three years in order to calculate limits for water treatment plants. I cannot continue reviewing the permit application and processing this renewal/transfer of coverage until these Flow values are confirmed. Permit Facility NCO056961 City of Asheville - DeBruhl WTP NCO056961 City of Asheville - DeBruhl WTP NCO056961 City of Asheville - DeBruhl WTP NCO056961 City of Asheville - DeBruhl WTP NCO056961 City of Asheville - DeBruhl WTP Month Day Year Param Class UoM Value Cell Type Location 2 1 2022 Flow mgd 0.676 DLYVALUE Effluent 2 3 2022 Flow mgd 0.68 DLYVALUE Effluent 2 4 2022 Flow mgd 0.665 DLYVALUE Effluent 2 6 2022 Flow mgd 0.682 DLYVALUE Effluent 2 7 2022 Flow mgd 0.67 DLYVALUE Effluent about: blank?windowld=SecondaryReadingPane6 3/5 7/17/24, 3:21 PM [External] Re: Permit Issuance for DeBruhl WTP (NCG590039) - Deuterman, Sydney - Outlook NCO056961 City of Asheville - DeBruhl WTP 2 9 2022 Flow mgd 0.675 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 11 2022 Flow mgd 0.675 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 13 2022 Flow mgd 0.683 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 15 2022 Flow mgd 0.671 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 17 2022 Flow mgd 0.676 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 18 2022 Flow mgd 0.67 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 20 2022 Flow mgd 0.673 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 22 2022 Flow mgd 0.677 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 24 2022 Flow mgd 0.679 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 26 2022 Flow mgd 0.673 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 28 2022 Flow mgd 0.681 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 7 3 2022 Flow mgd 0.679 DLYVALUE Effluent Additionally, if there had been any changes to the facility since the application was submitted, please let me know. If you have any questions about any of the above, please feel free to contact me at this email address or the number below. Thanks, Sydney Deuterman (she/her) Environmental Specialist II Compliance and Expedited Permitting Unit Division of Water Resources N.C. Department of Environmental Quality Office: 919-707-3712 s dnev.deuterman .Leq.nc.gov 1617 Mail Service Center Raleigh, NC 27699-1617 Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. Brenna Cook Compliance Manager City of Asheville Water Resources 828-259-5962 - Office William A. Hart 111 Water Production Division Manager City of Asheville Office #828-271-6103 William A. Hart 111 Water Production Division Manager City of Asheville about: blank?windowld=SecondaryReadingPane6 4/5 7/17/24, 3:21 PM [External] Re: Permit Issuance for DeBruhl WTP (NCG590039) - Deuterman, Sydney - Outlook Office #828-271-6103 about:blank?windowld=SecondaryReadingPane6 5/5 6/6/24, 4:15 PM Mail - Deuterman, Sydney - Outlook [External] Re: Permit Renewal for DeBruhl WTP (NC0056961 / NCG590039) Jud Bledsoe <jbledsoe@ashevillenc.gov> Thu 6/6/2024 4:02 PM To:Brenna Cook <bcook@ashevillenc.gov> Cc:Bill Hart <bhart@ashevillenc.gov>;Myrriah Ringgenberg <mringgenberg@ashevillenc.gov>;Deuterman, Sydney <sydney.deuterman@deq.nc.gov> B 2 attachments (3 MB) BW report 2_2022.pdf; BW report 7_2022.pdf, CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Sydney, I am looking at the records sheet now and it appears that all the data entry is off by a decimal point for all of February and also, July 3. 1 will go in and revise the report and have attached the bench sheets we use to track filter backwashes and volume of water used per filter each day in thousand gallon units(kgal). I must have overlooked the mistakes when I certified the reports. I will be sure to pay attention to this parameter moving forward. Thank you Sydney for bringing this to our attention. Please let me know if you have any questions or concerns. Regards, Jud On Thu, Jun 6, 2024 at 2:03 PM Brenna Cook <bcook@ashevillenc.gov> wrote: Hey Myrriah and Bill, Please see the email below about the wastewater permit renewal. Looks like data may have been entered incorrectly for Feb 2022 for the flow at Bee Tree. Please review and let Sydney with the State know. Sydney is copied on this email. Thanks Brenna ---------- Forwarded message --------- From: Deuterman, Sydney <sydney.deuterman@deq.nc.gov> Date: Thu, Jun 6, 2024 at 1:26 PM Subject: Permit Renewal for DeBruhl WTP (NC0056961 / NCG590039) To: bcook@ashevillenc.gov <bcook@ashevillenc.gov>, jbledsoe@ashevillenc.gov <jbledsoe@ashevillenc.gov> Hello, I am the permit writer assigned to this renewal. I apologize for the time it has taken for us to get to this renewal/transfer of coverage request. We have had a number of issues that have led to a backlog of renewals for our staff. I am currently in the process of reviewing your application and the criteria for the NCG590000 General Permit to see if your facility is eligible. Upon reviewing the flow data for this facility, I noticed inconsistencies in the daily flow reported for the month of February 2022. Every daily flow value reported in the month of February 2022 is between 0.683 MGD and 0.665 MGD. These numbers are significantly higher than the other daily flow values reported over the past 3-year period (minimum flow of 0.0503 MGD to a maximum of 0.2751 MGD). Similarly, a value of 0.679 MGD was reported for July 3, 2022. Please review the following flow numbers for February 2022 and July 3, 2022, and confirm if these numbers are indeed accurate. We use flow data from the past three years in order to calculate limits for water treatment plants. I cannot continue https://outlook.office.com/mail/inbox/id/AAMkADhhMjBhMWZiLWYyOGQtNGRkNil hMmRILTZIZGQwMWE3YTQ4ZgBGAAAAAAA3SVp2lpZ3S6CVG... 1 /3 6/6/24, 4:15 PM Mail - Deuterman, Sydney - Outlook reviewing the permit application and processing this renewal/transfer of coverage until these Flow values are confirmed. Permit Facility Month Day Year Param Class UoM Value Cell Type Location NCO056961 City of Asheville - DeBruhl WTP 2 1 2022 Flow mgd 0.676 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 3 2022 Flow mgd 0.68 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 4 2022 Flow mgd 0.665 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 6 2022 Flow mgd 0.682 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 7 2022 Flow mgd 0.67 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 9 2022 Flow mgd 0.675 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 11 2022 Flow mgd 0.675 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 13 2022 Flow mgd 0.683 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 15 2022 Flow mgd 0.671 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 17 2022 Flow mgd 0.676 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 18 2022 Flow mgd 0.67 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 20 2022 Flow mgd 0.673 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 22 2022 Flow mgd 0.677 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 24 2022 Flow mgd 0.679 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 26 2022 Flow mgd 0.673 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 2 28 2022 Flow mgd 0.681 DLYVALUE Effluent NCO056961 City of Asheville - DeBruhl WTP 7 3 2022 Flow mgd 0.679 DLYVALUE Effluent Additionally, if there had been any changes to the facility since the application was submitted, please let me know. If you have any questions about any of the above, please feel free to contact me at this email address or the number below. Thanks, Sydney Deuterman (she/her) Environmental Specialist II Compliance and Expedited Permitting Unit Division of Water Resources N.C. Department of Environmental Quality Office: 919-707-3712 5 dney.deuterman@)deq.nc.gov 1617 Mail Service Center Raleigh, NC 27699-1617 NORTH CAFOLINAD_ Np.d—t W Environmental Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties by an authorized state official. Brenna Cook Compliance Manager https://outlook.office.com/mail/inbox/id/AAMkADhhMjBhMWZiLWYyOGQtNGRkNil hMmRILTZIZGQwMWE3YTQ4ZgBGAAAAAAA3SVp2lpZ3S6CVG... 2/3 6/6/24, 4:15 PM Mail - Deuterman, Sydney - Outlook City of Asheville Water Resources 828-259-5962 - Office https://outlook.office.com/mail/inbox/id/AAMkADhhMjBhMWZiLWYyOGQtNGRkNil hMmRILTZIZGQwMWE3YTQ4ZgBGAAAAAAA3SVp2lpZ3S6CVG... 3/3 VFMonth and Year:? DeBruhl Water Treatment Facility Filter Backwash Report Citv of Asheville ©�-_----©E+yar�7•iil�il�J�l[87�11:�<Gi�iLJ11a[�L7r3� r UiFim��l�• ��'R/r3Li•�kL�l'1+JrT'iA©�--�--� m--_---ml•Lir■MA M �M11tiilal m�---__---m_--� tD j I Month and Year: �-(� ((� DeBruhl Water Treatment Facility Filter Backwash Report City of Asheville Run Time (123m) Filter Run i He2dloss Start Time 'Total Kgals Finish Run Timemi� Filter Run Headloss Start Time Total Kgals�, Finish Li -RqwMA;,,v =Of*!,T4k- 4-W EMOM W79 -41 Mug- LF M get Flo; ME "w. "10 M I. mri 'I M M MV�gm MON, 0 �M M M M