Loading...
HomeMy WebLinkAboutWQ0040884_MOD_Greensboro-Randolph_Megasite_FTSSE_Asbuilts_Phase_4_Record_Drawings_20240715PLEASANT GARDEN E CITY OF GREENSBORO WATER RESOURCES DEPARTMENT CLIMAX �G Begin Phase IV Construction JULIAN Force Main Sta 256+55 SANDY CREEK LIFT STATION J / �i End Phase IV Construction Force Main Sta 438+07 � I LOCATION MAP N.T.S. WATER RESOURCES DEPARTMENT APPROVED FOR CONSTRUCTION CITY OF GREENSBORO BY: jc/� C4 4-�4 WATER ESOURCE5 ADMINISTRATION DATE: 3/13 2-02. CONTACT EN6INEERIN6 CONSTRUCTION INSPECTIONS @ (336) 373 — 2377 ,BEFORE STARTING WORK RM SEWR PEIT No —y" &rxU-%4 05 54 WXM POW -IT NO BID DATE: CITY OF GREENSBORO ENGINEERING DIVISION APPROVED FOR CONSTRUCTION LI CONTACT (336) 373-2336 FOR ROADWAY CONSTRUCTION OR (336) 373-2377 FOR WATER AND SF\\'FR CONSTRUCTION PRIOR TO BEGINNING ANY WORK. SIGNED •CA DUODATE 3 131Z3 ENGINEERING DIVISION Contract Drawings For City of Greensboro Phase IV Sewer Force Main Extension Civil 24" Force Main: 18,152 LF Greensboro Project No. P05805C-006 Greensboro Contract No.2022-013 HDR Project No. 10328289 Greensboro, North Carolina January 2023 100% SUBMITTAL �N R0l 037518 01 /24/2023 . GENERAL NOTES ALL CONSTRUCTION SHALL CONFORM TO THE MOST CURRENT CITY OF GREENSBORO STANDARDS AND SPECIFICATIONS, ALL NC-DENR REGULATIONS AND ALL REQUIREMENTS FROM THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION'S POLICIES AND PROCEDURES FOR ACCOMMODATING UTILITIES ON HIGHWAY RIGHTS -OF -WAY. CONSTRUCTION SHALL COMPLY WITH ALL REQUIREMENTS SET FORTH IN ALL PERMITS RECEIVED FOR THE PROJECT, WHICH ARE INCLUDED IN THE CONTRACT SPECIFICATIONS. FOR REQUIREMENTS REGARDING UNDERGROUND UTILITIES, REFER TO "PROTECTION OF EXISTING UTILITIES" LOCATED IN THE SPECIFICATIONS UNDER "PROJECT SPECIAL PROVISIONS." DITCHES DISTURBED BY CONSTRUCTION SHALL BE SEEDED AND LINED WITH APPROPRIATE LINING TO PREVENT SOIL EROSION. SEE NOTES ON SEPARATE SHEETS. GROUND COVER MUST BE PROVIDED FOR DISTURBED AREAS AFTER EVERY 1,000 FEET OF LINE CONSTRUCTION AND AT NO TIME SHALL DISTURBED AREAS BE EXPOSED FOR MORE THAN 15 WORKING DAYS. ALL ENCASED PIPE SHALL BE RESTRAINED JOINT UNLESS OTHERWISE NOTED ON DRAWINGS OR IN SPECIFICATIONS. ALL STREAM CROSSINGS SHALL BE WITH RESTRAINED JOINTS. SEDIMENT MUST BE REMOVED FROM STREETS AS OFTEN AS NECESSARY TO PREVENT ANY BUILD-UP AND TO PREVENT WASHING OF SEDIMENT OUT OF CONSTRUCTION AREAS. DE -WATERING OF STRUCTURES WITH SEDIMENT -LADEN WATER DIRECTLY TO STREAMS IS PROHIBITED. CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED TANKS, PIPING AND APPURTENANCES AT AN APPROPRIATE OFF -SITE FACILITY. ENCROACHMENT PERMIT REQUIRED THROUGH NCDOT, CALL (336) 487-0100 FOR PERMIT. WQ PERMIT REQUIRED THROUGH NCDEQ. HDR Engineering, Inc. of the Carolinas N.C.B.E.L.S. License No. F-0116 440 S. Church St. Charlotte, NC 28202 704.338.6700 CONTRACT SHEET 1 OF 43 STANDARD TOPO SYMBOLS CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Existing Manhole 1/8" (labeled) ............................ 0 Proposed Manhole 1/8"....................................... is Telecommunications Manhole 1/8" (labeled) .................. Exist. Curb Inlet 5/32"-5/64" ............................... Im Prop. Curb Inlet 5/32"-5/64................................. m Telephone Booth 3/16"-5/16.................................. ❑d Exist. Telephone Or Power Pole 3/32......................... -0- Prop. Telephone Or Power Pole 3/32.......................... -� City Of Greensboro Signal Pole 3/32" (labeled) .............. ®«x GuyWire 3/32".............................................. v Exist. Hydrant 3/32"........................................ Prop. Hydrant 3/32"......................................... AK Water Valve 3/32" (labeled) ................................. 40 Traffic Engineering Signal Box 5/64"........................ ❑ GasValve 3/32"............................................. Grate or Drop Inlet (D.I.) 3/32............................. Right Of Way Monument 3/32"................................. 0 Iron Pipe 3/64.............................................. C aP Meter 5/64"................................................. IS Electrical Outlet 5/64" (labeled) ........................... 68M Telecommunications Box Or Pedestal 5/64" (labeled)......... ❑O Exist. Precise Traverse Point 7/64" (labeled)...............viv 18" Or Less Tree 1/4" (labeled) ............................. Over 20" Tree 5/16" (labeled) ............................... zo �� Shrub 5/32"................................................. Clean Out 1/16"-1/32" (labeled) ............................ OGp. Light Pole 3/32" (labeled) .................................. ® gar Wheelchair Ramp (City Of Greensboro Std. #418).............. wca Control Of Access Line 5/16................................. Exist. Water Line (labeled) ................................. W Prop. Water Line (labeled) .................................. W Exist. Sanitary Sewer (labeled) ............................. _ SS Prop. Sanitary Sewer (labeled) .............................. �• Exist. Right Of Way ......................................... ProposedMargin ............................................. — - - — Easement (labeled) .......................................... Temporary Construction Easement ............................. E Exist. Dirt Street .......................................... Exist. Pavment..............................................---v--Y- Exist. Curb (labeled) ..................................... ---------- Exist. Curb & Gutter (labeled) .............................. ---------- Prop. Curb & Gutter (shaded & labeled) ...................... SurveyLine ................................................. SlopeLine .................................................. ° --- Center Line ................................................. Exist. Storm Sewer (labeled) ................................ Prop. Storm Sewer (labeled) ................................. Gas Line (labeled) .......................................... G Transmission Line & Tower ................................... Underground Telecommunication Cable (labeled) .............. T Underground Power Line ...................................... P Fence (labeled) ............................................. X Railroad.................................................... Bridge (Prop. Solid & Exist. Broken) ........................ Box Culvert (Prop. Solid & Exist. Broken) ................... GuardRail .................................................. Hedges Or Bushes (labeled) .................................. ^ ^ ^^ ^^ WoodsLine .................................................. Exist. House ................................................ ,-zseo oo, Temporary Silt Fence ........................................ Erosion Control Device (COG Std. No. 215 & 432)............. ^ INDEX OF DRAWINGS GENERAL PROJECT NOTES CONSTRUCTION SEQUENCE GENERAL 1. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SITE SAFETY ASSOCIATED WITH THE WORK UNDER THIS PROJECT AND FOR COMPLIANCE 1. OBTAIN AND MAINTAIN ON SITE THE LAND DISTURBING PERMIT FROM NCDEQ. WITH ALL FEDERAL, STATE, AND LOCAL HEALTH AND SAFETY LAWS, CODES, REGULATIONS, AND ORDINANCES INCLUDING BUT NOT LIMITED TO THOSE CURRENTLY MANDATED BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA). 2. NOTIFY THE NCDEQ AT LEAST 48 HOURS PRIOR TO BEGINNING WORK. 1 OOG-00 COVER SHEET 2 OOG-01 SHEET LIST INDEX AND PROJECT NOTES 2. CONTRACTOR SHALL USE ADEQUATE SHORING METHODS TO ENSURE: 3. HOLD PRE -CONSTRUCTION MEETING. 3 OOG-03 SHEET ORIENTATION PLAN A. COMPLIANCE WITH OSHA REGULATIONS. 4. ALL POTENTIALLY AFFECTED PROPERTY OWNERS MUST BE NOTIFIED PRIOR TO UTILITY 4 OOG-04 ABBREVIATIONS AND GENERAL SYMBOLS B. PROTECTION OF EXISTING PAVEMENT AND ROAD SHOULDERS. CONSTRUCTION EVEN THOUGH THE ACTIVITY IS COVERED UNDER AN EASEMENT. [G.S. C. CONSTRUCTION ACTIVITIES ARE CONFINED TO RIGHTS -OF -WAY OR EASEMENTS AS INDICATED. 11A-54.19A1] 24" FORCE MAIN PLANS AND PROFILES 5. INSTALL ALL EROSION & SEDIMENT CONTROL MEASURES AS SHOWN ON THE PLANS PRIOR TO 3. CONTRACTOR SHALL INSTALL GRAVITY SEWER AND MANHOLES AS INDICATED ON PLANS AND SHALL NOT DISTURB ANY AREA OUTSIDE THE ANY SITE DISTURBANCE ACTIVITIES (CLEARING, GRUBBING, GRADING, OR EXCAVATION). EASEMENT LIMITS SHOWN ON THE PLANS. 5 04C-01 PLAN & PROFILE STA 251+50 TO STA 259+50 6. ALL CLEARING AND GRUBBING ARE TO STAY WITHIN LIMITS AS SHOWN ON THE PLANS. 6 04C-02 PLAN & PROFILE STA 259+50 TO STA 269+50 4. CONTRACTOR IS RESPONSIBLE FOR REPAIR/REPLACEMENT OF ALL MAINTAINED PAVEMENT DAMAGED BY CONSTRUCTION ACTIVITIES TO 7. AS NOTED ON THE PLANS, NO WORK SHALL BE DONE IN AREAS OF WETLANDS AND STREAMS 7 04C-03 PLAN & PROFILE STA 269+50 TO STA 279+50 SATISFACTION OF NCDOT, GUILFORD COUNTY, RANDOLPH COUNTY AND THE CITY OF GREENSBORO. NO SEPARATE PAYMENT SHALL BE UNTIL THE 401/404 PERMITS ARE OBTAINED. 8 04C-04 PLAN & PROFILE STA 279+50 TO STA 289+50 MADE FOR PAVEMENT REPAIR EXCEPT AS NOTED ON PLANS. 9 04C-05 PLAN & PROFILE STA 289+50 TO STA 300+25 8. IN WORK ZONE AREAS: 10 04C-06 PLAN & PROFILE STA 300+25 TO STA 310+00 5. CONTRACTOR IS RESPONSIBLE FOR RESTORING ALL EXISTING CONDITIONS DISTURBED DUE TO CONSTRUCTION ACTIVITIES TO THEIR 8.1. INSTALL SILT FENCE AND DOWNSTREAM EROSION CONTROL MEASURES. ENSURE THAT 11 04C-07 PLAN & PROFILE STA 310+00 TO STA 320+00 ORIGINAL LOCATION AND CONDITION UNLESS OTHERWISE NOTED ON PLANS. RESTORATION OF THESE FEATURES SHALL BE AT NO PRIOR WORK AREA IS CLOSED, SEEDED AND MATTED (IF CALLED OUT ON THE PLANS). 12 04C-08 PLAN & PROFILE STA 320+00 TO STA 330+00 ADDITIONAL COST. 8.2. CONTRACTOR SHALL ESTABLISH CLEAN WATER DIVERSION SWALES AS DETAILED UPSLOPE 13 04C-09 PLAN & PROFILE STA 330+00 TO STA 340+00 OF TRENCH LOCATION WHERE ROOM EXISTS BETWEEN LOD AND PROPOSED SEWERLINE. 14 04C-10 PLAN & PROFILE STA 340+00 TO STA 350+00 6. LOCATION OF EXISTING UTILITIES SHOWN ON THESE PLANS ARE NOT INTENDED TO BE EXACT OR COMPLETE. THE CONTRACTOR SHALL 8.3. CONTRACTOR SHALL NOT OPEN UP ANY MORE TRENCH THAN CAN BE CLOSED AT THE END OF COORDINATE WITH ALL UTILITY COMPANIES AND FIELD VERIFY THE LOCATION AND DEPTH OF ALL UTILITIES PRIOR TO CONSTRUCTION. 15 04C-11 PLAN & PROFILE STA 350+00 TO STA 360+00 LOCATE WELL AHEAD OF PIPE LAYING OPERATIONS TO ALLOW FOR ADJUSTMENT. NO SEPARATE PAYMENT WILL BE MADE FOR FIELD THE DAY. 16 04C-12 PLAN & PROFILE STA 360+00 TO STA 370+00 VERIFICATION OR ADJUSTMENT AS REQUIRED. ADJUSTMENTS TO LAYOUT SHOWN SHALL BE SUBJECT TO ENGINEER APPROVAL. 8.4. SET EXCAVATED MATERIAL ON THE HIGH SIDE OF THE TRENCH SO THAT TRENCH WILL ACT AS 17 04C-13 PLAN & PROFILE STA 370+00 TO STA 380+00 CONTRACTOR SHALL REPAIR, AT HIS OWN EXPENSE, ANY DAMAGE CAUSED BY CONSTRUCTION -RELATED ACTIVITIES TO EXISTING UTILITY A BASIN SHOULD THERE BE A POP-UP STORM. 18 04C-14 PLAN & PROFILE STA 380+00 TO STA 390+00 LINES. 8.5. REVIEW IN THE FIELD LOCATIONS WHERE SEDIMENT LADEN RUN-OFF MAY ESCAPE. PROVIDE 19 04C-15 PLAN & PROFILE STA 390+00 TO STA 400+00 EXTRA MEASURES AS NECESSARY TO MAINTAIN A SEDIMENT SECURE SITE. 20 04C-16 PLAN & PROFILE STA 400+00 TO STA 410+00 7. IN THE EVENT OF DAMAGE TO EXISTING UTILITIES, CONTRACTOR SHALL STOP WORK IMMEDIATELY, TAKE NECESSARY PRECAUTIONS TO 8.6. APPLY STABILIZATION MEASURES AS SOON AS PIPE IS SET AND TRENCH BACKFILLED AND 21 04C-17 PLAN & PROFILE STA 410+00 TO STA 420+00 PREVENT INJURY OR FURTHER DAMAGE, AND NOTIFY PROPER AUTHORITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPACTED. 22 04C-18 PLAN & PROFILE STA 420+00 TO STA 430+00 RESTORING/REPAIRING ALL EXISTING STRUCTURES, CONDUITS, OR OTHER UTILITIES DAMAGED BY CONTRACTOR'S OPERATIONS AT NO 8.7. IT IS RECOMMENDED THAT SEEDING OCCUR WITHIN 7 DAYS OF OPENING DISTURBED AREAS. 23 04C-19 PLAN & PROFILE STA 430+00 TO STA 438+07 COST TO OWNER. 8.8. WORK WITH THE NCDEQ INSPECTOR ON THE USE OF WATTLES VERSUS ROCK CHECK DAMS EROSION CONTROL PLANS AT VARIOUS LOCATIONS. 8. THE CONTRACTOR SHALL RECONSTRUCT ALL ROAD SHOULDERS, DRAINAGE DITCHES AND SWALES DISTURBED BY CONSTRUCTION ACTIVITIES TO THEIR ORIGINAL GRADE AND LOCATION. 24 04E-01 EROSION CONTROL PLAN FORCE MAIN STA 256+00 TO STA 269+50 9. ANY OFFSITE BORROW AND WASTE REQUIRED FOR THIS PROJECT MUST COME FROM A SITE WITH 25 04E-02 EROSION CONTROL PLAN FORCE MAIN STA 269+50 TO STA 289+50 9. TRAFFIC CONTROL SHALL BE MAINTAINED IN ACCORDANCE WITH NCDOT SPECIFICATIONS AND REQUIREMENTS. AN APPROVED EROSION CONTROL PLAN, A SITE REGULATED UNDER THE MINING ACT OF 1971, OR 26 04E-03 EROSION CONTROL PLAN FORCE MAIN STA 289+50 TO STA 310+00 A LANDFILL REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT. TRASH/DEBRIS FROM 27 04E-04 EROSION CONTROL PLAN FORCE MAIN STA 310+00 TO STA 330+00 10. ALL HOLES, TRENCHES, AND OTHER HAZARDOUS AREAS SHALL BE ADEQUATELY PROTECTED BY BARRICADES, LIGHTS OR OTHER DEMOLITION ACTIVITIES OR GENERATED BY ANY ACTIVITIES ON SITE MUST BE DISPOSED OF AT A 28 04E-05 EROSION CONTROL PLAN FORCE MAIN STA 330+00 TO STA 350+00 PROTECTIVE DEVICES. FACILITY REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT OR PER DIVISION OF SOLID WASTE MANAGEMENT OR DIVISION OF WATER RESOURCES RULES AND REGULATIONS. [15A 29 04E-06 EROSION CONTROL PLAN FORCE MAIN STA 350+00 TO STA 370+00 NCAC 48 .0110] 30 04E-07 EROSION CONTROL PLAN FORCE MAIN STA 370+00 TO STA 390+00 11. REMOVAL OF EXCAVATED MATERIALS AND DAILY CLEANUP OPERATIONS SHALL BE PERFORMED IN COMPLIANCE WITH THE SPECIFICATIONS 31 04E-08 EROSION CONTROL PLAN FORCE MAIN STA 390+00 TO STA 410+00 AND TO THE SATISFACTION OF THE OWNER/ENGINEER, AND/OR NCDOT. 10. INSPECT ALL EROSION CONTROL DEVICES AT WEEKLY INTERVALS AND AFTER EVERY RAINFALL 32 04E-09 EROSION CONTROL PLAN FORCE MAIN STA 410+00 TO STA 430+00 EVENT EXCEEDING 1.0 INCH TO VERIFY THAT THEY ARE FUNCTIONING PROPERLY. ANY 33 04E-10 EROSION CONTROL PLAN FORCE MAIN STA 430+00 TO STA 439+00 12. ALL ROCKS, BRUSH, TIMBER, AND OTHER DEBRIS THAT IS CLEARED FROM THE RIGHTS -OF -WAY SHALL BE REMOVED FROM THE PREMISES ACCUMULATED SEDIMENT SHALL BE REMOVED AND PLACED IN A DESIGNATED SPOIL DISPOSAL AND SHALL NOT BE BURIED WITHIN THE RIGHT-OF-WAY OR PLACED ON ADJOINING LANDS, EXCEPT WHERE ARRANGEMENTS FOR SUCH AREA APPROVED BY THE INSPECTOR. CONDUCT PERIODIC INSPECTIONS OF ALL EROSION AND PLACEMENT OR DISPOSAL ARE MADE WITH THE APPROPRIATE PROPERTY OWNERS. SEDIMENTATION CONTROLS AND MAKE ANY REPAIRS OR MODIFICATIONS NECESSARY TO ASSURE DETAILS CONTINUED EFFECTIVE OPERATION OF EACH DEVICE. 13. ALL TREE PROTECTION AND EROSION AND SEDIMENTATION CONTROLS SHALL BE IMPLEMENTED BEFORE CONSTRUCTION COMMENCES AND SHALL NOT BE REMOVED UNTIL RE -VEGETATION HAS BEEN ESTABLISHED. 11. THERE ARE AREAS WITHIN THE PROJECT WHERE THERE ARE LARGE DRAINAGE AREAS FLOWING 34 04D-01 STANDARD CIVIL DETAILS THROUGH THE LIMITS OF DISTURBANCE. FOLLOW "CONCENTRATED FLOW CROSSING 35 04D-02 STANDARD CIVIL DETAILS 14. ANY AGREEMENT BETWEEN THE CONTRACTOR AND PROPERTY OWNERS SHALL BE MADE IN WRITING AND COPIED TO THE OWNER. CONSTRUCTION SEQUENCE" IN THESE AREAS AS PROVIDED ON THIS SHEET. 36 04D-03 TRAFFIC CONTROL DETAILS 12. FOLLOW THE CHART ON THIS SHEET FOR ESTABLISHING CHANNEL MATTING. 37 04D-04 NCDEQ NOTES 15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE ENGINEER WITH A SET OF SURVEY RECORD (AS -BUILT) DRAWINGS 38 04D-05 NCDEQ NOTES PREPARED BY A NORTH CAROLINA REGISTERED LAND SURVEYOR CERTIFYING THE ACCURACY OF THE SURVEY HORIZONTAL AND VERTICAL 13. AFTER STABILIZATION IS ESTABLISHED, THE CONTRACTOR SHALL WORK WITH NCDEQ TO OBTAIN 39 04D-06 EROSION CONTROL DETAILS LOCATIONS TO ONE TENTH (0.10) OF A FOOT. SURVEY SHALL BE TIED TO THE NORTH CAROLINA STATE PLANE COORDINATE SYSTEM (NAD83 APPROVAL FOR REMOVING EROSION CONTROL BMPs. 40 04D-07 EROSION CONTROL DETAILS FEET) HORIZONTALLY, AND ELEVATIONS SHALL BE NORTH AMERICAN VERTICAL DATUM (NAVD88). SURVEY POINT INFORMATION SHALL BE 41 04D-08 EROSION CONTROL DETAILS PROVIDED IN AN ELECTRONIC FORMAT (EITHER AN AUTOCAD [VERSION 2020 OR EARLIER] DWG FILE OR AN ASCII POINT TEXT FILE [X-Y 42 04D-09 EROSION CONTROL NOTES COORDINATES]). 43 04D-10 EROSION CONTROL NOTES THESE DRAWINGS SHALL AT A MINIMUM SHOW THE FINAL ELEVATIONS AND HORIZONTAL LOCATIONS FOR ALL MANHOLES, PIPING INVERTS WITHIN MANHOLES, AND FITTING LOCATIONS. CONTRACTOR SHALL PROVIDE THE ENGINEER WITH A LETTER CERTIFYING TO THEIR COMPLIANCE WITH THE CONTRACT DRAWINGS. EROSION CONTROL NOTES AND SEQUENCES 16. SEE DETAIL SHEETS FOR STANDARD EROSION CONTROL NOTES. 17. CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION STAKING. 18. NOT ALL TREES OR VEGETATION ARE SHOWN ON DRAWINGS. NO EXTRA PAYMENT WILL BE GIVEN FOR REMOVING TREES NOT SHOWN. REMOVE ALL TREES WITHIN EASEMENT LIMITS. VEGETATION OUTSIDE EASEMENT LIMITS IS NOT TO BE DISTURBED. 19. ANY DRIVEWAY PIPES DISTURBED DURING CONSTRUCTION SHALL BE REPLACED WITH MIN. 15" CLASS IV RCP. 20. MANHOLES WITHIN 50' OF WETLAND AREAS SHALL ADHERE TO THE FOLLOWING RULES, PER NCDEQ ALTERNATIVE DESIGN CRITERIA FOR MINIMUM SEPARATION FOR SEWER SYSTEMS TO WETLANDS - PART D (AUGUST 2008): - MANHOLES SHALL BE PROVIDED WITH A WATERTIGHT FRAME AND COVER WITH GASKET. - ALL MANHOLE SEAMS SHALL BE EXTERNALLY TAPED/SEALED. - MANHOLES SHALL BE PROVIDED WITH A FULL WATERPROOF INTERIOR COATING/LINING. - WATERTIGHT PIPE CONNECTIONS SHALL BE PROVIDED CONSISTING OF A FLEXIBLE RUBBER BOOT OR COMPRESSION TYPE CONNECTOR. - ALL MANHOLES SHALL BE TESTED IN ACCORDANCE WITH ASTM C1244 "STANDARD TEST METHOD FOR CONCRETE SEWER MANHOLES BY THE NEGATIVE AIR PRESSURE (VACUUM) TEST PRIOR TO BACKFILL". - "DOG HOUSE" TYPE MANHOLES SHALL NOT BE USED. - ALL MANHOLES NOT INCLUDED AS PART OF A USACOE 404 PERMIT OR DIVISION 401 CERTIFICATION SHALL MAINTAIN A SEPARATION OF NO LESS THAN 10 FEET FROM WETLANDS. 21. SEWER MAINS WITHIN 50' OF WETLAND AREAS SHALL BE CONSTRUCTED TO WATER MAIN STANDARDS (15A NCAC 18C), PER 15A NCAC 2T .0305 (9)- 22. CONTRACTOR SHALL HAVE THE OPTION TO USE DIP OR PVC PIPE FOR INSTALLATION. 23. ALL ENCASED PIPE SHALL BE RESTRAINED JOINT UNLESS OTHERWISE NOTED ON DRAWINGS OR IN SPECIFICATIONS. 24. ALL AIR RELEASE VALVE MANHOLES SHALL BE LINED TO PROTECT FROM SEWER GASES WITH A MINIMUM EPDXY COATING OF 80-125 MILS. 25. ALL DUCTILE IRON FITTINGS AND APPURTENANCES TO HAVE PROTECTO 401 OR APPROVED EQUAL. CONCENTRATED FLOW CROSSING CONSTRUCTION SEQUENCE: 1) INSTALL EROSION CONTROL MEASURES TO THE LEFT AND RIGHT OF DITCH CROSSING. 2) CONTRACTOR TO WATCH WEATHER FOR STRETCH OF A MINIMUM 4 DRY DAYS. 3) CONTRACTOR TO ENSURE THAT ALL EROSION AND SEDIMENT CONTROL MEASURES ARE AVAILABLE AT THE SITE FOR INSTALLATION. 4) OPEN -CUT AND INSTALL CROSSING IN ONE DAY ENSURING THAT STABILIZATION IS IN PLACE INCLUDING RIP -RAP APRON AT END OF DAY. ❑A (ac) Matting 0-1 Seed and Straw 1-3 S15OBN 3-7 C350 >7 P300 with reinforced 'vegetation Assumptions: Slopes less than or equal to 3% Swales seeded and mulched where no matting required F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 d _ ( CONTRACT SHEET 3 of 43 WOODY MILL RD �O O� rycV F'A�� J� PROP. PHAS I 16" WATERLINE AN J 16 FORCE MAIN o (NOT IN CONTRACT) Q s oc Q 0 o O� PROP. PHASE II 16 WATERLINE (NOT IN CONTRACT) z = ONNETT 02 47 BEDROCK RD Ro PROP. PHASE III 16" WATERLINE AND 24" FORCE MAIN (NOT IN CONTRACT) FUTURE PHASE III _ 16" WATERLINE ILFORDCOU NT (NOT IN CONTRACT) ANDOLPH COUNT \ Phase IV Begin Construction 9 04C-01 �1 RO STA 251 +50 0 04C-02 C/) Z 3 �/S Q O 04C-03 3 O O Of 04C-04 m Lv Q r 04C-05 04C-06 S oy 04C-07 �O 04C-08 04C-09 04C-10 04C-11 04C-12 ROPOSED PHASE IV 04C-13 Sr 24 FORCE MAIN qR vNl 04C-17 04C-18 SANDY '000 Phase IV End Construction CREEK LIFT �`p�•••'ESS%'•�/ STATION ��%p•'y STA 438+07 04C-19 037518 01 /24/2023 c r THINNN. K— HDR Engineering, Inc. REVISIONS TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05808D CITY OF GREENSBOROof the Carolinas OOG-03 NCBELSLicense No. F-0116 ROADWAY DESIGNED 11 2022 BY MAS,DC WATER RESOURCES D E P A R TM E N 440 S. Church St., Suite 1200 SEWER 2022-006A CONST. SURVEY BY SANDY CREEK SEWER LIFT STATION SHEET N0. Charlotte, NC 28202-2075 704.338.6700 REISSUED IN CO-1 WATER CHECKED BY DTB ORIENTATION PLAN OF FOR CONSTRUCTION SIDEWALK SCALE: NOT TO SCALE 3 43 CONTRACT SHEET 5 of 432m Ess�p��y': 037518 01 /24/2023 c r �'�•. THIN W � �.�`. K- HDR Engineering, Inc. REVISIONS TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05808D CITY OF GREENSBORO olinas OOG-03 NCBELSof the 'License No. F-0116 ROADWAY DESIGNED 11 2022 BY MAS WATER RESOURCES D E P A R TM E N Charlotte, S.te,NC 8202-ite5 SEWER 2022-006A CONST. SURVEY BY SANDY CREEK SEWER LIFT STATION SHEET NO. Charlotte, NC 28202-2075 704.338.6700 REISSUED IN CO-1 WATER CHECKED BY ABBREVIATIONS AND GENERAL SYMBOLS 4 OF 43 FOR CONSTRUCTION SIDEWALK SCALE: NONE MATERIALS IN PLAN/SECTION GENERAL SYMBOLOGY ABBREVIATIONS A, AMP AMPERE FCA FLANGED COUPLING ADAPTER NF NON —FUSED ARROW INDICATES TARGET ELEVATION © AT FD FLOOR DRAIN NO NORMALLY OPEN/NUMBER ACOUSTICAL CEILING TILE (SECTION) DIRECTION OF AB ANCHOR BOLT FDN FOUNDATION NOM NOMINAL PLAN NORTH ABC AGGREGATE BASE COURSE FFE FINISHED FLOOR ELEVATION NTS NOT TO SCALE AC ALTERNATING CURRENT FIN FINISHED NPT NATIONAL PIPE THREAD ASPHALT (PLAN OR SMALL—SCALE SECTION) ACI AMERICAN CONCRETE INSTITUTE FL, FLR FLOOR NS NEAR SIDE PLAN ARCHITECTURAL ACSR ALUMINUM CABLE STEEL REINFORCED FLA FULL LOAD AMPS CIA OVERALL ASPHALT (LARGE—SCALE SECTION) 1/4" 1'-0" AD ADD ACCESS DOOR ADDENDUM FLG FLOUR FLANGE FLUORESCENT OC,O/C OD ON CENTER OUTSIDE DIAMETER = ROOM OIT OPERATOR INTERFACE TERMINAL NAME ADDL ADDITIONAL F/0 FIBER OPTIC PLAN TITLE ADJ ADJACENT FO FINISHED OPENING/FAIL OPEN OPH OPPOSITE HAND BATT INSULATION (SECTION) XX—XX ROOM NUMBER � AF AMP FRAME FOB FLAT ON BOTTOM OPNG OPENING AFF ABOVE FINISHED FLOOR FOT FLAT ON TOP OPP OPPOSITE SECTION LETTER XXX DOOR NUMBER AFG AGGR ABOVE FINISHED GRADE AGGREGATE FPT FRP FLOOR PLATE FIBER REINFORCED PLASTIC ORP P OXIDATION REDUCTION POTENTIAL PIPE BRICK MASONRY (PLAN AND/OR SECTION) X AHU AIR HANDLING UNIT PB PULL BOX FS FAR SIDE FLAG INDICATES DIRECTION AIC AMPS INTERRUPTION CAPACITY FT FOOT OR FEET PCCP PRESTRESSED CONCRETE CYLINDER PIPE OF SECTION CUT A COLUMN GRID LINE (SYMMETRICAL) FTG FOOTING PCF POUNDS PER CUBIC FOOT CHECKERED PLATE (PLAN) X AL, ALUM ALUMINUM FLIT FUTURE PE PLAIN END XXX ALTN ALTERNATE FWD FORWARD PF POWER FACTOR o a a SHEET WHERE SECTION � WALL TYPE AMB AMBIENT GA GAGE PH PHASE a CONCRETE (PLAN AND/OR SECTION) IS LOCATED ANDZ ANODIZED GAL GALLONS PL PLATE CONCRETE MASONRY AND/OR SECTION CUT MARKER O WINDOW TYPE APPR AT APPROXIMATE AMP TRIP GALV GEN GALVANIZED GENERATOR PLC PNL PROGRAMMABLE LOGIC CONTROLLER PANEL (PLAN SECTION) ATM ATMOSPHERE GFCI GROUND FAULT CIRCUIT INTERRUPT PNT PAINT AUTO AUTOMATIC GPM GALLONS PER MINUTE PP POWER POLE SECTION LETTER �X LOUVER AUX AUXILLIARY GND GROUND PROJ PROJECTION DEMOLITION (PLAN AND/OR SECTION) SECTION AVG AVERAGE GV GATE VALVE PROP PROPOSED X AWG AMERICAN WIRE GAGE HC HOLLOW CORE PSC PRESTRESSED CONCRETE EARTH SECTION (SECTION) 3/8" — 1'-0" XXX OX ACCESSORY, FURNITURE, BET BF BETWEEN HDW HARDWARE PSF PSI POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH SHEET WHERE BLIND FLANGE, BOTH FACES, HEX HEXAGONAL SECTION VIEW IS AND MISCELLANEOUS BOTTOM FACE HH HANDHOLE PSIG POUNDS PER SQUARE INCH GAUGE FIRST CUT * EQUIPMENT IDENTIFIER BLDG BUILDING HID HIGH INTENSITY DISCHARGE PT POINT, POINT OF TANGENCY FILTER POINT MAT (PLAN) BLK BLOCK HK HOOK PUE PUBLIC UTILITY EASEMENT SECTION TITLE BLKG BLOCKING HM HOLLOW METAL PVC POLYVINYL CHLORIDE KEY NOTE DESIGNATION BM BENCH MARK HOA HAND —OFF —AUTOMATIC PVMT PAVEMENT FINISHED WOOD (SECTION) BOP BOTTOM OF PIPE HOAR HAND —OFF —AUTOMATIC —REMOTE PWR POWER BOT OR B/ BOTTOM HORIZ HORIZONTAL P/LF POUNDS PER LINEAL FOOT GLULAM LUMBER (SECTION) DETAIL NUMBER # KEY NOTE NUMBER (#—f BP BRG BASE PLATE BEARING HP HPS HORSEPOWER, HIGH POINT, HEAT PUMP HIGH PRESSURE SODIUM RAID RED RADIUS REDUCER BRGPL BEARING PLATE HPT HIGH POINT REF REFERENCE o �0����0� XXX SHEET WHERE DETAIL IS LOCATED BS BTU BOTH SIDES BRITISH THERMAL UNIT HSB HT HIGH STRENGTH BOLT HEIGHT REINF READ REINFORCED,REINFORCING REQUIRED GRANULAR FILL (SECTION) BV BALL VALVE HV HIGH VOLTAGE REV REVISED, REVISION DETAIL MARKER C CONDUIT HVAC HEATING, VENTILATING AND AIR CONDITIONING RGS RIGID GALVANIZED STEEL CONDUIT GENERAL LINE SYMBOLOGY GRATING (SECTION) FOR REFERENCING DETAILS INCLUDED IN DRAWING SET. BTOI AWATER E C/C CENTER CENTER HWR HEATED RETURN RJ RESTRAINED JOINT CFM CUBIC FEET PER MINUTE HWS HEATED WATER SUPPLY RL ROOF LOAD GRATING (PLAN) XXXXXXXXX CHWR CHILLED WATER RETURN HZ HERTZ RLA RUNNING LOAD AMPS CHWS CHILLED WATER SUPPLY ID INSIDE DIAMETER RM ROOM DETAIL MARKER 4—HOUR FIRE RATED WALL CIR CIRCUMFERENCE IE INVERT ELEVATION RO ROUGH OPENING . GROUT (SECTION) CJ CONSTRUCTION JOINT IG ISOLATED GROUND ROW RIGHT OF WAY ° FOR REFERENCING DETAILS BOUND IN CKT CIRCUIT IN INCHES RTU REMOTE TERMINAL UNIT SPECIFICATIONS OR SEPARATE VOLUME. 3—HOUR FIRE RATED WALL CLG CEILING INC INCLUDING RVAT REDUCE VOLTAGE AUTO TRANSFORMER GYPSUM BOARD (SECTION) CLKG CAULKING INFO INFORMATION RVSS REDUCED VOLTAGE SOLID STATE CLR CLEAR INSTL INSTALL, INSTALLATION R/W RIGHT OF WAY METAL (SECTION) DETAIL NUMBER DETAIL 2—HOUR FIRE RATED WALL CO COM CLEANOUT COMMON INSUL INTR INSULATION INTERIOR OR INTERMEDIATE RPZ S BACKFLOW PREVENTOR SOUTH # 1—HOUR FIRE RATED WALL COMB COMBINATION ISB INTRINSIC SAFETY BARRIER SCH SCHEDULE 3" = 1'-0" XXX CONC CONCRETE ISDPS INFLUENT STRUCTURE DRAIN PUMPING STATION SECT SECTION ORIENTED STRAND BOARD (SECTION) SHEET WHERE DETAIL CONN CONNECTION JB JUNCTION BOX SHT SHEET WAS CALLED OUT * COLUMN GRID LINE/CENTERLINE CONT CONTINUOUS J, JCT JUNCTION SIG SIGNAL CONTR CONTRACTOR JF JOINT FILLER SIM SIMILAR PARTICLE BOARD (SECTION) CPLG COUPLING JT JOINT SPD SURGE PROTECTION DEVICE DETAIL TITLE IDENTIFICATION SYMBOLOGY S KIP SPEC SPEC SQ SPECIFICATION SQUARE PLYWOOD (LARGE—SCALE SECTION) ELEVATION NUMBER CT CTD CURRENTTRANSFORMERKCMIL CENTER, CENTERED kV CIRCULAR MILLS KILOVOLTS ST STEEL PIPING CTL CONTROL JOINT kVA KILOVOLT AMPERES STD STANDARD ARROW INDICATES X POINT OF VIEW CTR CENTER kW KILOWATT STL STEEL PLYWOOD (SMALL—SCALE SECTION) XX FIGURE 36—PLE EXAMPLE CTRL CUFT CONTROL CUBIC FOOT LA LIGHTING ARRESTOR STRL SUSP STRUCTURAL SUSPEND SHEET WHERE ELEVATION LBS POUNDS a PRECAST CONCRETE (PLAN AND/OR IS LOCATED * � CUYD DC CUBIC YARD DIRECT CURRENT LC LF LOCKED CLOSED LINEAR FEET SW SYM STILLING WELL SYMMETRICAL SECTION) SINGLE ELEVATION OR PHOTO MARKER LINE SIZE 36" DCJ DOWELED CONTROL JOINT LG LONG SYS SYSTEM SERVICE PLANT EFFLUENT DE DRAINAGE EASEMENT LH LEFT HAND TC TCE TOP OF CURB TEMPORARY CONSTRUCTION EASEMENT RIGID INSULATION (SECTION) DEM DEMOLITION LL LIVE LOAD ELEVATION NUMBER DET DETAIL LO LOCKED OPEN TBcB TOP AND BOTTOM DI DUCTILE IRON LOC'N LOCATION TEMP TEMPERATURE �oO RIPRAP (PLAN AND/OR SECTION) ARROW INDICATES POINT OF VIEW ELEVATION EQUIPMENT IDENTIFICATION DIA DIAG DIAMETER DIAGONAL LOD LP LIMITS OF DISTURBANCE LOW POINT, LIGHTING PANEL TERM THK/TH TERMINAL THICK D B <:> DIM DIMENSION LR LONG RADIUS TO OR T/ TOP OF INDICATES SHEET WHERE ALTERNATIVE 1 DIP DUCTILE IRON PIPE LTG LIGHTING TOC OR T/GONG TOP OF CONCRETE SAND (SECTION) ELEVATION IS LOCATED NPWP2023 DISC DISCONNECT LTS LIGHTS TOG TOP OF GRATING FIGURE EXAMPLE DpNUE MAINTENANCE UTILITY EASEMENT LV LOW VOLTAGE TOS OR T/STL TOP OF STEEL C MULTIPLE ELEVATION OR PHOTO MARKER DO DOWN DISSOLVED OXYGEN LWL LOW WATER LEVEL TOW OR T/WALL TP TOP OF WALL TURNING POINT SOD (SECTION) SERVICE INDICATES DWG DRAWING MAN MANUAL TRD TREAD ABBREVIATION NON —POTABLE WATER DWL DOWEL MATL MATERIAL TS TEMPERATURE SWITCH WEEP JOINT MORTAR ELEVATION EQUIPMENT E EAST MAX MAXIMUM TSP TWISTED SHIELDED PAIR PROTECTION SYSTEM (SECTION) IDENTIFICATION INDICATES PUMP EA EACH MB MACHINE BOLT ' TYP TYPICAL NUMBER ABBREVIATION MBH THOUSAND BTU S PER HOUR ELEVATION BUILDING OR EF EACH FACE, EXHAUST FAN MBR MEMBER UE UNDERGROUND ELECTRICAL ® WOOD — CONTINUOUS (SECTION) X STRUCTURE BUILDING 20 EJ EXPANSION JOINT MCA MAXIMUM CONTINUOUS AMPS UG UNDERGROUND 3 = 1 —0 XXX NUMBER EJF EXPANSION JOINT FILLER MCC MOTOR CONTROL CENTER UON,UNO UNLESS OTHERWISE NOTED WOOD BLOCKING (SECTION) SHEET WHERE POINT EL, ELEV ELEVATION MCCB MOLDED CASE CIRCUIT BREAKER V VOLT OF VIEW MARKER CAN EQUIPMENT PUMP 23 ELEC ELECTRICAL MCOP MAXIMUM OVER CURRENT PROTECTION VA VOLT AMPERE BE FOUND * NUMBER ELL EMBED ELBOW EMBEDMENT MECH MECHANICAL VB VAPOR BARRIER GENERAL NOTES: ALTERNATIVE 2 ENCL ENCLOSURE MET METAL VBX VERT VALVE BOX VERTICAL ELEVATION TITLE EOP EDGE OF PAVEMENT MFR MANUFACTURER VFD VARIABLE FREQUENCY DRIVE 1. THIS IS A STANDARD SHEET SHOWING COMMON * EXCEPTIONS WHERE THE SHEET NUMBER IS REPLACED BY A NPWP-23 FIGURE EXAMPLE EPS EFFLUENT PUMPING STATION MH MIN MANHOLE, METAL HALIDE MINIMUM W WATTS/WEST/WIRE SYMBOLOGY. ALL SYMBOLS ARE NOT NECESSARILY DASH (—). T EQ EQUAL MISC MISCELLANEOUS WL WATER LEVEL USED ON THIS PROJECT. 1) FOR COMMON DETAILS, SECTIONS, ELEVATIONS OR DETAILS SERVICE INDICATES EQUIP ETM EQUIPMENT ELAPSE TIME METER MJ MECHANICAL JOINT WM WIRE MESH THAT ARE CUT OR CALLED OUT ON MULTIPLE SHEETS. ABBREVIATION NON —POTABLE WATER EW EACH WAY MO MASONRY OPENING WP WEATHERPROOF 2. SCREENING OR SHADING OF WORK IS USED TO 2 SECTIONS, ELEVATIONS OR DETAILS THAT ARE LOCATED ON EQUIPMENT EX EXISTING MTD MOUNTED W / WITH INDICATE EXISTING COMPONENTS OR TO INDICATES PUMP MTG MOUNTING W/0 WITHOUT DE—EMPHASIZE PROPOSED IMPROVEMENTS TO THE SAME SHEET THEY ARE CUT OR CALLED OUT ON. ABBREVIATION EXIST EXISTING N NORTH, NEUTRAL YD YARD HIGHLIGHT SELECTED TRADE WORK. REFER TO EQUIPMENT EXP EXPANSION NC NORMALLY CLOSED YH YARD HYDRANT CONTEXT OF EACH SHEET FOR USAGE. NUMBER PUMP 23 EXPO EXPOSED ND NORMALLY DE —ENERGIZED Z/C TS Z CONDUCTOR TWISTED SHIELDED CABLE EXT °F EXTERIOR NEC NORMALLY ENERGIZED 2/C TS 2 CONDUCTOR TWISTED SHIELDED CABLE FAHRENHEIT NE NATIONAL ELECTRIC CODE 3/C TS 3 CONDUCTOR TWISTED SHIELDED CABLE FA FC FOUL AIR FAIL CLOSED NEUT NEUTRAL DIMENSION TO BE VERIFIED WITH OR AS REQUIRED * FOR PURCHASED ITEM 0048E (6-1358J)(P-05805A-06) / I TOYOTA BATTERY MANUFACTURING, INC. / 6142 JULIAN AIRPORT RD f RC REID 92504 / 8 2810 PC, 1683, (1) PARCEL 71 REFER TO SHEET 04E-01 G EASEMENT DB 2805 PG 841 FOR EROSION CONTROL / I i INSTALLED AS i/ 0075E(P-05805(_-06) APART OF / TOYOTA BATTERY PHASE III NIC / MANUFACTURING, INC. ( ) 4621 IRON HORSE TR °yam j°eoj / / \cb \/'91 \ / RC REID 92504 ° ' \\ o° ° , DB 2810 PG 1683, (1) PARCEL 70 / \'yam e� 4° /� / \ j �x STA 256+55 �g,�( 4 ^ \ BEGIN PROJECT REMOVE EXISTING 24 RJ / 4k PLUG AND CONNECT TO e / °y ��o� �' \ ° \� / EXISTING 24" FORCE MAIN APPROXIMATE LOCATION OF GATE VALVE INSTALLED / PUE (WIDTH VARIES) O DURING PHASE III. \y r\ \ \\ A / PROP. 24" 11.25' RJ FITTING / °z� F / �° °° % k �i STA 257+22 PROP. FORCE MAIN \ J \ N 783801 /� / v 4 COMBINATION �� \ \, E 1807831 /V/ °�� / / / / � e � /� AIR VALVE W/ 6' MH \ \\ , STA 256+79 N 783833 E 1807860 go NL/G 6'E0° / PROP.. 24" C-900 DR-18\ FORCE MAIN 05 SEPTIC DRAIN FIELD / // INSTALL 8' OFF (n EDGE OF PAVEMENT 0074W (P 05805C O6) ROGER DALE 6135 JULIAN AIRPORT RD RC REID 74064 D8 1116, PG. 25 / MBH 790 U) U Lo Q +0 LO IUD_J 780 Q Q C 770 PROFILE OVER 24" C-900 DR-18 FORCE MAIN EXISTING GRADE I 760 Z Q Z w JOU w�� U��OLLuJ w U- ONZN0-`n �LO wZO�co >Oz Z_ 0 U Z N 0 2 0 (D Q w w z X w mWQwmcn EXISIFIBER OPTIC O i �T 750—�- 1 _ — — — - —------- — -- -�I _____________ ___-- --- --------------------------------------------------------- — — 740 PPROXIMATE LOCATION OF GATE VALVE INSTALLED CON TRUCTED IN PHASE III iNOT IN CON RACTI DURING PHASE III. 730 720 710 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 N U)Z � O �0 Q � rn INSTALL 24" FORCE MAIN AT A DEPTH Z_ w r— REQUIRED TO PROVIDE A MINIMUM C° J 0 6 5 Q U) 1. 0 COVER OF 4' BELOW EXISTING GRADE O > N ti Q Cn x ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER ALL PIPE SHALL BE INSTALLED ON POSITIVE SLOPE OF 0.1 % OR GREATER I 252+00 253+00 254+00 255+00 REVISIONS REVISED PER NCDEQ COMMENTS 100% SUBMITTAL 256+00 TYPE ROADWAY SEWER WATER SIDEWALK CONTRACT 2022-013C " C-900 DR18 PIPE 0076E (P-05805C-06) TOYOTA BATTERY MANUFACTURING, INC.. 4622 IRON HORSE TR RC REID 92504 DB 2810 P61683, (1) PARCEL 53 IRON HORSE TRAIL (GRAVEL) 257+00 258+00 259+00 NTRACTOR AS —BUILT 1AUTH. DATE I WATER AND SEWER PERMITS �O u7 u7 cV 790 H U) 780 770 760 750 GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. KEY NOTES: OEDGE OF PAVEMENT IS LIMITS OF DISTURBANCE. ORIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. OPUE LINE IS LIMITS OF DISTURBANCE. 4O LOCATION AND DEPTH UNVERIFIED. FIELD LOCATE PRIOR TO TRENCHING ACTIVITIES. CONTRACT SHEET 5 OF 43 SENSITIVE INFORMATIO Not to be copied or distributed without the express written permission of the City of Greensboro. MNIbrtifIoli nas , www.nc811.org Clay COG Water eso s e 73-2033 GDOT Trao Si a 73-2606 COG/Gui1f rd Co. Telecom _ 73-2084 COG Wat upPIY _ — — — — — Tanks Te tment Plants /73-5855 GDOT St rni ter _ — — — 13�73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 HORIZONTAL SCALE IN FEET 10 0 10 VERTICAL SCALE IN FEET 740 I 730 720 CARS �•��N ,� LU 710 Z U I — a JOB NO. P-05805C DESIGNED 11/2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED 037518 01 /24/2023 K- CITY OF GREENSBORO WATER RESOURCES DEPARTMEN GRMS Phase IV Sewer Force Main Extension OLD 421 ROAD AT JULIAN AIRPORT ROAD PLAN AND PROFILE STA 251 +50 TO STA 259+50 20 04C— 01 SHEET NO. 5 OF 413 i I I REFER TO SHEET 04E-01 Z I i FOR EROSION CONTROL 0078E (P-05805C-O6) 0076E (P-05805C-06) 0077E (P-05805C-06) TOYOTA BATTERY MANUFACTURING, INC. TOYOTA BATTERY TOYOTA BATTERY I 5950 JULIAN AIRPORT RD IMANUFACTURING, INC.. MANUFACTURING, INC. RC REID 74052 5990 JULIAN AIRPORT RD 4622 IRON HORSE TR RC REID 74084 I DB 2810, PG 1683; (5) PARCEL 75 RC REID 92504 DB 2810, PG 1683 DB 1011, PG 138, NCDOT R/W D8 2810 PG 1683, (1) PARCEL 53 PB 121, PG 27, LOT 1 (5) PARCEL 15 I D8 2648, PG 325, COG UTILITY EASEMENT I DB 1011, PG 128, NCDOT RIGHT OF WAY I DB 1011, PG 138, NCDOT RIGHT OF WAY i I I ITRANSITION FROM TOFF EOP TO 11' OFF EOP PROP. 24" C-900 DR-18 FORCE MAIN I II I INSTALL T OFF I I I N h I EDGE OF PAVEMENT I > 0 I 24" FORCE MAIN w co/ \ TREES I I ,� INSTALL 6' OFF > / 1 I I I ° TREES II Q II I TREE EDGE OF PAVEMENT °\ °T CD CD �e INV. 38.72' > I ° TREES 15" RCP � i I0079E (P-05805C-06) TOYOTA BATTERY MANUFACTURING, INC. 5938 JULIAN AIRPORT RD I RC REID 92593 DB 2810, PG 1683, (5) PARCEL 16 DB 1782, PG 2430 (VERIZON WIRELESS TOWER AGREEMENT) I D8 1011, PG 146 NCDOT RIGHT OF WAY D81515, PG 25, DUKE POWER COMPANY EASEMENT D81736, PG 2416, DUKE POWER COMPANY EASEMENT I TRANSITION FROM 11' OFF EOP TO 6' OFF EOP i OPEN CUT AND REPAIR GRAVEL DRIVE (15.10 TON) INV. 736.16' O u7 CO N ,r IU) I I I I I MK IN 743.1 IN . 741.70' / I II > I o TREES Inv. In 746.08 I MKR PROP. 40'x10' AT&T _ x-%—%—x — — / Inv. Out 745.48 I I AND — — x _ GUY I I I LAUNCHING PIT r �67 �HANDHOLE — — \ _f F 4 P VAULT ° FM / 268+00 1F" PE FM26 00 \ �F°�__ I 2 _ �/� -- F / -- -- OH/P °ON OH/P�_ OH/P FI/P P P — — _ _ MKR_ _ — — Foc � � �� — — _ — — — — — — — — — — — — -- F FOCI FOC— FOC— FO{�� F+° F M s * F I - nF FOC— [O�FT�J FM ° / Q \ OC t FOC— FOC FOC— 3+0VOC _ _ _ _ \ _ _ _ � PROP.10'x10' F°° RECEIVING PIT / p 26� - FM FM - Z - �p FM �— `�� B-97 9 _ _ -� \ \ \ �� FOC_ F M K_ I`- r�r�0�p FOC— FOC— FOC— +oo FOC— 1 — _ L� LE7 FOC— \_ \ °� Foc F°° FOC +Q� SIGN OH/P IFM FM -------------------- \ I _ _ - -- Vie- -- _------- 9 Q --2MB ----------- =�/ M F CID- �Z; ---L --------/P�o--------- SR ZS02 ° EX. PROPERTY LINE__ __-- 3 -- — i� --T oMB \ pRJ �� PIPE p pT ;T _ `, QL 12" RCP NiP�Dy/P ORT RD _-----------------� DR 7 ��Q SIGN DR IPEI PP IPt —CHA LIN ENCE _ TEL ��Y `f �W PIPE 1� _ Inv. In 751.46 1 JULIAN AIRP - V _ _ _ - - _ _ - \ PIPE PIPE (� L Iz ° M B � P P OH/P -OH/P OH/P OH OH P OH/P �� lEL SIGN 1 OH/P OH/P I OH/Pi PP , / 1 Inv. Out 751.45_--2MB ---- -----� /P �DR� I OH/P OH/P °HP 1 °/P ' J DR °„ \OM/P �EL�L IPPEI OH/P OH/P OH/P OH/P �/P � II I I PROP. 90 LF OF -j- OH/P I 36 STEEL CASING I 0 �P P E O /P OH/P OH/P P P I I Lu = s N I I ) PP i II �PP J I\ I II I PIPE, 0.531" w x a z I Q I I I I I I w I, I I WAL ICKNESS I > 45 LL x I o I N I I I I I I o I /� � Y I ICI I I \ wl ICI I J oy I JI > IZ II I ^I I �I lol I 0 I> I II I / �� Q%I o `�I J C Q 1 =I w o Q SHED I > I Q H I% I� < I I Of I I I_ J I CD ElI CD I I CD I MBH I I MBH o i t-- -� I 1—SBD I Q I I i I I I 000 �—, � ATRE��S�II PP M-�1—SBD MBH Mt MBH U ra 770 760 750 740 730 720 710 700 LU Z_ J U H a F)l 30+00 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 GRAVEL W 0- 0- + o (0 N oa z� W Cn 12" 261+00 z 262+00 PROFILE OVER I 24" C-900 DR-18 FORCE MAIN EXISTING GRADE I GRAVEL GRADE AT SITE CONSTRUCTION ACCESS ROAD BASED ON DESIGN INFORMATION (NIC) 15 RC 24" C-900 DR18PIPE INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW EXISTING GRADE ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER I 1 1 263+00 264+00 265+00 REVISIONS TYPE ROADWAY SEWER WATER 100% SUBMITTAL SIDEWALK O GRAVEL DRIVE r 12" PROP. 90 LFT 36" STEEL CASING PIPE, 0.531" WALL THICKNES O W �- 0 M + N zWE GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. KEY NOTES: 0 EDGE OF PAVEMENT IS LIMITS OF DISTURBANCE. O2 RIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. OPUE LINE IS LIMITS OF DISTURBANCE. 4O LOCATION AND DEPTH UNVERIFIED. FIELD LOCATE PRIOR TO TRENCHING ACTIVITIES. O5 DO NOT DISTURB FENCE. OINSTALL STEEL CASING PIPE USING TRENCHLESS CONSTRUCTION METHODS IN ACCORDANCE WITH CONTRACT SPECIFICATIONS. ALL PIPE WITHIN THE CASING PIPE SHALL BE RESTRAINED JOINT PIPE. 0ABANDONED WELL. OMEGASITE SUPPLY AND CONSTRUCTION ACCESS ROAD TO TRAILER CITY. MAINTAIN ACCESS AT ALL TIMES. OLIMITS OF DISTURBANCE. CONTRACT SHEET 6 of 43 SENSITIVE INFORMATIO Not to be copied or distributed without the express written permission of the City of Greensboro. North 8� Carolinas , � www.nc811.org CHy COG Water eso s e 73-2033 GDOT Traffi Si a — — — 73-2606 COG/Guilf rd Co. Telecom _ 73-2084 COG Wat upply - — — — — — Tanks ,Te tment Plants /73-5855 GDOT St rrri ter _ — — — 13�73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 iiia LO HORIZONTAL SCALE IN FEET + 10 0 10 20 O� CV 780 VERTICAL SCALE IN FEET �U) 770 760 GRAVEL DRIVE 750 15' RCP 18" HDPE 740 z_ 730 I 720 I 710CAR6� 19- SS MOSt37518 W 700 01 /24/2023 , c LU JNEP� W • .•`� H 266+00 267+00 268+00 269+00 CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805C CITY OF GREENSBORO WATER RESOURCES DEPARTMEN 04C-02 DESIGNED 11 2022 BY MAS 2022-013C CONST. SURVEY BY GRMS Phase IV Sewer Force Main Extension JULIAN AIRPORT ROAD AT CALHOUN DRIVE PLAN AND PROFILE STA 259+50 TO STA 269+50 SHEET NO. CHECKED BY 6 OF 43 SCALE: AS NOTED I I I I / REFER TO SHEET 04E-02 Z I FOR EROSION CONTROL I I I I I I / 0080E (P-05805C-06) I 0081E (P-05805C-06) 0079E (P-05805C-06) I TOYOTA BATTERY MANUFACTURING, INC. I ! TOYOTA BATTERY TOYOTA BATTERY MANUFACTURING, INC. 5742 JULIAN AIRPORT RD MANUFACTURING, INC. 5938 JULIAN AIRPORT RD RC REID 74080 I / 5772 JULIAN AIRPORT RD RC REID 92593 I DB 2810, PG 1683; (5) PARCEL 76 I RC REID 74040 DB 2810, P61683, (5) PARCEL 16 I DB 1011, P6147, NCDOT RIGHT OF WAY I DB 2810, 1683; (5) PARCEL 78 DB 1782, PC, 2430 (VERIZON WIRELESS TOWER AGREEMENT) I DB 2648, P6 325, CO& UTILITY EASEMENT I / P8 54, P6 40, LOT 1 DB 1011, P6146 NCDOT RIGHT OF WAY DB 1515, P6 25, DUKE POWER COMPANY EASEMENT DB 1736, P6 2416, DUKE POWER COMPANY EASEMENT I I - I I PROP. 24" C 900 DR-18 FORCE MAIN / 194STALL 6' OFF / !� EDGE OF PAVEMENT // I // O M / / / / n BRUSH TRANSITION FROM 6' OFF EOP LO oO I N , TREES Q TO 11' OFF EOP / i /" C �� Co w r� LLJ PRO . 69 LF OF \ J /� / i TREES �I I I / ^ / ^ 3 TEEL C SING PIPE, 0.531" /�t , � - TRANSITIO FROM 11' O F/POP / I� I FIBER—OPTIC CABLE / / 2 // / / / / I W L �i HICKVESS ` _ I / TO 2 OFF EOP HANDHOLE / / / / / / I INV. 716.19, I d I GATE I \� 3 ,� _�.-�.—%—.—.�. .—. .�. .f—•--<% .-/-. /�/—X-y-X—X-X_—�—%-7/ INV. 15.33' - _ - - IIII )\ _ .—x—x x—x / _ i J I/ P�g 1 - - / / 2 2 I - --r-- ��----' _ -'- -- -- -- / --� -- -� - I - 7 +0 / ��$�-eo� T I SIGN- = �7�+0� - r - - - _ 4" \ FM - - - - - - - - - _ c FM _ _ I -r� — rlVl �T FIYI — —J _ �f96� FOC �FOC —FOC—� FOC—FOC = — — — — — — — — — — — — — c — — — — — — — — — — FOCI—FOC_�FOC— FOC— FOC— FOC— FOC— FOC— FOC FOC FOC FOC—�F9C FOC—_FOC—_ FOC FOC —TOC—=TEE FOC FOG = FOC FOC � �-- FOC— FOC F / FOC— FOC FOC FO II- - --- -- ----y-------------- -- — �; ------ ------------ --- — Imo_ — __f T _ � 15" RCP i JULIAN AIRPORT PAI�J30 ILL__ _ _ _ _24" RCP_ _ _ _ _ _ Inv. In 714.78 j I I ORT RD SR 2502 / '&Xt-1807585.253 8 8 — — — Inv. In 710.69 I_ — �� 1 Inv. Out 714.44 / / EX. CONIC APRON 1 Inv. Out 710.47 �� EX. PROPERTY LINE----- __-- __----\__— / / _-1 JY=782357.449 �__-----_ ___ __ __ —/--_— / ---—72 ��5 �T—TAT—T—T—T TT—TTTTTTT --- i_T_T-_T�T�T\�\ / —T _7�T=-��—'Z T7�—T— TT DR '` DF� �M� �� — �� — DR�— �" — — _p SIGN DR PIPE T — — — �plg IIPP / II q PIPE �SIG 1�1 �\ �� �\ \ PIPES ��� — --- BRUSH — I _ IGN / I p \ / \ PP / PP IIn, w O IH/P � OH/P/ OH/P OH/P OH/P OH/P —T � '' — OH/POH/P OH/P � P 1 OH/P / OH/P OH/PI OH/P OH/P OH/P OH/PZ — P OH/P PP I I OHIP OH/P OH/P OH/P OH/P OH/P 0�/P OH OH/P OH/1 = I I I Q S I I I I 0 o I TREE I � I I I � m Ed I Itxll I ` \ \ \ I I ► \ � � \ I I -� I I __--- I ofI 1 \ \ \ I I I \ rTREES I o 0 �� I x xxx • ---_ I I BRUSH MBH / �� 4_ ) I:) \I CH IN LINK FENCE PID 1-SBD w o � � O CD LO O-) co 750 CV Q H 07 I 740 730 720 710 700 I 690 680 I 670 LU J U Q 270+00 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. v EDGE OF PAVEMENT IS LIMITS OF DISTURBANCE. ORIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. OPUE LINE IS LIMITS OF DISTURBANCE. ONCDOT RIGHT-OF-WAY LIMIT. OEXISTING 20' WIDE PUE PER G-1271C. O20' PUE. 0MEGASITE SUPPLY AND CONSTRUCTION ACCESS ROAD TO TRAILER CITY. MAINTAIN ACCESS AT ALL TIMES. OLIMITS OF DISTURBANCE. �y� vn/y off/P�Of ryo PROP. 24" 22.5° RJ FITTING STA 279+02 N 78166 E 18075 7 / CD O-) ti CV 750 Q H 07 I 740 GRADE AT SITE CONSTRUCTION ACCESS ROAD BASED ON DESIGN GRAVEL INFORMATION (NIC) DRIVE 730 24" RCP RAVEL PROFILE OVER FUT RE ROADWAY 24" C-900 DR-18 FORCE MAIN IMPROVEMENTS EXISTING GRADE PR P. FINAL 24" RCR GRP DE (NIC) - 720 _ f I N - I 710 z 24" C-900 DR18 PIPE-J 700 z LEI 690 INSTALL 24" FORCE MAIN AT A DEPTH a- 00 N REQUIRED TO PROVIDE A MINIMUM o 0� o COVER OF 4' BELOW EXISTING GRADE z °�° N N N N °° U) N U) 680 z 670 ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER = U I 271+00 272+00 273+00 274+00 275+00 276+00 277+00 278+00 279+00 REVISIONS TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805C ROADWAY DESIGNED 11 2022 BY MAS SEWER 2022-013C CONST. SURVEY BY REVISED PER NCDEQ COMMENTS WATER CHECKED BY 100% SUBMITTAL SIDEWALK SCALE: AS NOTED CONTRACT SHEET 7 of 43 SENSITIVE INFORMATIO Not to be copied or distributed without the express written permission of the City of Greensboro. North 8� Carolina , www.nc811.org City of Gree oro a rounc 1 Locate(So e quests COG Waters e 73-2033 GDOT Traffi _ — _ 73-2606 COG/Guilf. Telecom — 73-2084 COG Water - — _ — _ — ,73-5855 Tanks/TrPlantsGDOT Storm _ — — — -373-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET �._SEAC �= 037518 '; 01 /24/2023 , ell K— CITY OF GREENSBORO 04C-03 WATER RESOURCES DEPARTMEN GRMS Phase IV Sewer Force Main Extension SHEET NO. JULIAN AIRPORT ROAD AT WOODVERY DRIVE PLAN AND PROFILE 7 OF 43 STA 269+50 TO STA 279+50 4i/ CONC // l 0082E(P-05805C-06) / 0082E (P-05805C-06) T l TOYOTA BATTERY / TOYOTA BATTERY \, l / MANUFACTURING, INC. MANUFACTURING, INC. / / 5742 JULIAN AIRPORT RD / RC REID 74041 \ / RC REID 74080 DB 2810, PG 1683; (5) PARCEL 77 DB 2810, PG 1683; (5) PARCEL 76 PROP. 24" 22.5° RJ FITTING STA 279+99 y / N 781576 / E 1807610 PROP. 24" GATE VALVE STA 280+08 / \ N 781566 O E 1807611 �'706U-1 i `707 , — I I \ \>/ \\\ \ \ I\ I I �\` I 3 GENERAL NOTES: CONTRACT SHEET REFER TO SHEET 04E-02 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY 8 OF 43 FOR EROSION CONTROL SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER SENSITIVE INFORMATION MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN Not t0 be copied Or ALIGNMENTS. distributed without the 0084E (P-05805C-06) TOYOTA BATTERY KEYNOTES: express written MANUFACTURING, INC. RC REID74075 � permission of the City DB 2810, PG 1683, (2)PARCEL 55A LIMITS OF DISTURBANCE. 0 of Greensboro. PROP. FORCE MAIN / OPEN CUT - — — _ 4" COMBINATION AIR VALVE _ �� AND REPAIR W/ 6' MH // �� GRAVEL DRIVE PROP. 24" C-900 DR-18 FORCE MAIN STA 280+21 (6.35 TONS) INSTALL 9' OFF 1 3 781554 / _� EDGE OF PAVEMENT \ �I 1807611 GO � vroAo a ° 3 / — \ \00 \ 1 r\� Fjy 00 I1-1 `OQ \ \ I n \ \ LOD + 284+00 / \ I N t LOD �\ -I I �= FM ;:z I z \' F� \�� 4 _ = LOD � x �} FM — SOD / // / l -44 I I I LOD LOD _ LOD �—/ LOD LOD LOD/ /I J ►— oR — ek p� ' \� _ ��P X �l l ' ' I I I I F oc RE JULIAN IRPORT RD SR 2502 aleVP 0/ 0 /O/ /P < P 715 / l a l 0083E (P-05805C-06) TOYOTA BATTERY T°MANUFACTURING, INC. °/P� ll °"/" \ 700JULIANAIRPORTRD O"/P FOC I I r - RC REID 74033 I l\e l l \ \ °"/a '° \ l 2 / / �S" y / �<vl 08 2810, 1683; (5) PARCEL 59 D / �n Rcp �l I I O LO O ti 750 cV �I co 740 I I 730 720 710 700 i I 690 I I 680 I 670 z J U w J Q Q z O - Q z N N fY] _ +o00 0 0 O- N U0 _ U 9M W + I.- o Q tb U Q N CO z 2 zo An GRAVEL PROFILE OV R 900 D -18 24" C-FORCE MAIN EXISTING G AIDE —�— J----L4---I----L---1 z -v W a o o + CL N 00 N N N Q 0 Q NJ Cn W Cn ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER 280+00 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 z INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW PROP FINISH GRADE ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE' OF 0.1 % OR GREATER 281+00 282+00 283+00 284+00 285+00 REVISIONS TYPE ROADWAY 1 2 3 4 SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK \ I \ I VOp oz� ti a 00 \ \ /' CDC LQ OC e/ =r °o CT�// i hQ r p �/ Q / 68,0lj��/ 0085E (P-05805C-06� oz� GELLMAN, IA N SC TT (GELLMAN, BREYANN ICOLE) 5616 JULIAN AIR OR T RD Q RC REID 89,414 % DB 2699, P 1474 P8162, PG 5, LOT 1 DB 1160, PG 1110. ACCESS EASEMENT DB 2598, PG 2�7DUKE ENERGY or OPTION MEMORANDUM 286+00 287+00 288+00 CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS 2022-013C 4:I'IIllft 2O RIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. OPUE LINE (REFERENCE NCDOT PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1) IS LIMITS OF DISTURBANCE. 4O NCDOT REVISED RIGHT-OF-WAY LIMIT. NCDOT PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1. OPROVIDE 2'x2' CONCRETE PAD AROUND VALVE. OEXISTING 20' PUE. REFER TO G-1271C. EASEMENT NOT NEEDED FOR CONSTRUCTION IN THIS AREA. NO DISTURBANCE IS PERMITTED BEYOND DEFINED LIMITS OF DISTURBANCE. 0 NCDOT EASEMENT, NCDOT PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1. OFUTURE NCDOT ROADWAY WORK. NOT IN CONTRACT. O LO O') 00 CV 750 I< IU) 740 730 720 710 700 ••1 .:1 I LU 670 J U AL 1NOD 8� 04alirana www.nc811.org� , City of Grime r e round Loc els I o e Jules" COG Water eso s e 73-2033 GDOT Traffi Si a 73-2606 COG/Guilf rd Co. Telecom _ 73-2084 COG Wat r upply - — — — — _ 73-5855 Tanks ire tment Plants GDOT St rni ter _ — ——73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET 037518 .12/20/2023 c %.y.FNG T�`lElfV W `NPR' JOB NO. P-05805C CITY OF GR EEN SB OR O WATER RESOURCES DEPARTMENT 04C— 04 DESIGNED 8 2023 BY MAS CONST. SURVEY BY GRMS Phase IV Sewer Force Main Extension JULIAN AIRPORT ROAD PLAN AND PROFILE STA 279+50 TO STA 289+50 SHEET NO. CHECKED BY 8 OF 43 --1 SCALE: AS NOTED (P-05805C-06) \ JAMES K. GEORGEVICH, I I I \ \ I I .\ /, �AND WIFE \ \ ` \ \� I � I I I I \ 0084E (P-05805C-06) l / / / / / / i / ` \ \ JUDIANN E. GEOR6EVICH \ °' TOYOTA BATTERY /l I 4606 CRUTCHFIELD FARM RDI \I \\\ I \ \ \ \ \ \ \ REFER TO SHEET 04E-03 MANUFACTURING, INC. / RC REID 74078 FOR EROSION CONTROL�w RC REID 74075 DB 1950, PG 2104 I i , ' I I/ / /" \/ IrnDB 2810, PG1683,(2) PARCEL 55A P8 101, PG 54, LOT 2 PROP. 24" 45o RJ rn FITTINGI I I I I I 1 / \ O\ I I I I I STA 298+ 10 °R1ie °�ie\\ �'� \ i I I N 780311 I 8 / I aim / I E 1808679 /Dal '6� PROP. 24" 45° RJ FITTING w I I ogle STA 298+03 / I LO i I 676 N 780314 8 I ayeE 1808673 BD I�� rn I 75 0 C��' �' ' � l l I l I �� 2F �. � 674 (a/Oa1/'`O�' `o o� NIIQ/ �'��ie� / \ \�—s-- O\ O REPAIR GRAVEOPEN CUT L // / / i / / , // / �i / a�i O o e G o \ \ 670 _ — �'� / // // �O ap o�ip0�/ // / // / e' G Oi o i I ` PROP. 24' 45 RJ FITTING \�, — / / / / / i co 1, G0\ t \ STA 296+79 - —\— —669 / <p 1 KEi M N DRIVE (6.50 TON) / �e Q �/' / a�IQ� / / / / / e� rn \ I N 780267 P / I ~ I 7 / htii / / / / / / / / / / �. �� \ E 1808558 — — _ _ i' zCO U) / '' 1 e/j�� / / / -\_ e \ \ \ '"01a �'� 180 LF OF / / / e/ / ' ` / / // // //9�i // / / i I PROP. 24" C-900 DR-18 FO MA \ \ \ ro ��`O �� „ �O 36 STEEL CASI PIP PROP. 24" 11.25° RJ FITTING I _ `�- 4 0.375" WALL T I KN SS +00 / ` \ STA 296+73 Y. / i g �S /' FM o�/ F / / FAA / FM +00 I / N 780269 N \ / I / IFM \ E 1808552 \ 1 / ` / cD / LOD, / / L¢D / — LOD e LOD I IPD I I \ \ ` \ \ \ \ \ \ \\ \ / l 8 LOD TL WN AN � \ \ \ � � � �FNj \ \ � \ \ \ \ / g / / PRO ale \ \ LO \ \ oil W I ­17—I e \ e \ \ \ LOD y' I C ' z I FUTU JUL AN AIRPORT-RD I SR 2 \ J I I i ie' I 1 ie�k\ —� \ PROP. 24" 22.5° RJ FITTING 2 \ NC1D STA 295+36 \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ I \ \ » „ E 1808436 � \ \ \ \ \ \ \ s \ \ 1 \ \ 18iQ CP III 1 RCP�III` ,T HE_0 1 8 /�i�\ �\ 8 \ ` , \ , \ Q04 \RCP—hq � � A 4 6\ °alQ °pie 241, \ aie // 0085E (P 05805C O6) \ \ 6, rn c� O m � °'� 6'� S I I \ � , — I \ \ L AAdN TAN SCOTT \ 6' �6' ao — \ �6 69 6� 8 �j cv� �� ��,, co -. Lo co co co co co co I I I I / v \ (6EL1MAN, BREYANN NI 693 \ ` 69 91, \ O 9\ �, t I I `�-�� \ °' �)° \)O Dale ,O °° 699 6'9 69)\ 696/ 56._ ULIAN AIRPORT RD \ 1 I (P-05805C-0 \/ 3, , 7 RC REID 89414 \ \ \ I I I I I / ALFRED NOLAND CRUTCNFIEL' I I DB 2699, PG 1474 _ \ e \ \ \ \ I RC REID 89415 I o�ie \ \ \ \ / P8 162, PG 555, LOT 1 - ` \ \ \ \ \ GE I I I I I / I DB 2261, P61704 O DB 1160, PC 1110. \ \ \ \ \ \ \I I I I PS 162, PG 55, LOT 18 \ \ \ \ \ ow? \ \ \ DB 2598, P6 247, DUKE ENERGY \ e/ \ OPTION MEMORANDUM \ \ I I IBDO 1101�11 O LO CA 00 710 CV Q H Cn 700 .:1 670 .•1 650 640 I 630 LLI z U Q FUTURE ACCESS TO DUKE ERGY EASE PROFILE OVER 24" C-900 DR-18 FORCE AIN EXISTING GRADE z_ \ INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW PROP FINISH GRADE " C-900 DR118 PIPE W � ILL o co Q-' if � L! Z N N N 0 Q N Q m (n N U) W 0- N W CO �co �+ zLO N W H oQ m(o W Ico ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER I I I I I ILL rn ro o L0 N ' Q N (n 0 ti LO + N N � Q N (n z 0 + C� 00 o Ln Z N Q N El Co 0 z LL M O 1' + o � U) N Q N (n PROPOSED ROADWAY 180LFOF _-- 3 ,, --__ 0.375° SING PIPE, WALL THICKNESS O GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. U LIMITS OF DISTURBANCE. 2O RIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. OPUE LINE (REFERENCE NCDOT PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1) IS LIMITS OF DISTURBANCE. ONCDOT REVISED RIGHT-OF-WAY LIMIT. NCDOT PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1. OPROVIDE 2'x2' CONCRETE PAD AROUND VALVE. OINSTALL 36" STEEL CASING PIPE BY OPEN CUT. 0 NCDOT EASEMENT. NCDOT PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1. OFUTURE NCDOT ROADWAY WORK. NOT IN CONTRACT. 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET LO CV O O co 710 �U) 700 690 680 670 660 650 640 W 630 z U Q CONTRACT SHEET 9 of 43 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. � 41 Nod �� 8� Carolina W W W.nc811.Ofg� , City COG Water eso s e 73-2033 GDOT Traffi Sig. a _ _ — 73-2606 COG/Guilf rd Co. Telecom _ 73-2084 COG Wat r upply — — — — _ 73-5855 Tanks 1`re tment Plants GDOT St rni ter _ — — — 73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. K- 290+00 291+00 292+00 293+00 294+00 295+00 296+00 297+00 298+00 299+00 300+00 REVISIONS TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805C CITY OF GR EEN SB OR O HDR Engineering, Inc. of the NCBELSrLicense No. F-0116 ROADWAY DESIGNED 8 2023 BY MAS WATER RESOURCES DEPARTMENT 440 S. ChurchCharlotte, NC 82ozzo7500 1 2 3 4 SEWER 2022-013C CONST. SURVEY BY GRMS Phase IV Sewer Force Main Extension 704.338.6700 REVISED PER NCDEQ COMMENTS WATER CHECKED BY 24" FORCE MAIN JULIAN AIRPORT ROAD PLAN AND PROFILE 100% SUBMITTAL SIDEWALK SCALE: AS NOTED STA 289+50 TO STA 300+25 C A Pp''! 037518 .12/20/2023 c 04C— 05 SHEET NO. 9 of 43 I ' ' I I I I I / ♦ \ / / / / / --==_--=_642=\\\\\ IALFRED M. CRUTCHFIELD AND I — — � I � � ' / � � '� — — � 645 I � CA��WIFE, I III_ III LAS.-eRirCHFrELD I / / � jai i/ =— + �_�—�` ��\ �/ I I I I � \\\\\ \\\ \\ I I I III REFER TO SHEET 04E-03 c°5536JULIAN AIRPORTRD 6FOR EROSION CONTROLCREID81093 2746 17 / / 63.8- _II / �/ � / � ,\\\ , 610 I / // // // / / I 'ice- = \\�\ \ \ \ I I \ \ \ \ 1 1 I I I I I I I I I �S \ / 639— _ \ \ \ \ \ \ I I / N ,640 // // /// / //'/�-/ / \ \ \� \\ \ \\vJ \ \ \ \ \ \1 1 ICI I I I I / / E \111 III �6q.1—'/ � — \ I I I I _ // // /// — _ /655,/ 1 8 5C-0 I I I I I l / ,6�2- / / / / / / / j / / / / // _ - - - \ / / \ \\ \ \ \ I I I I I I I JAM 5 K. &€ORGEVICH, I I I I — �\ _ �� / / / / / / / L� _ - \ / l _ \ 1� \ \ \ �, / / \ \ 111 1 I I I I I I I I / / x / / / ` 0 I �\ AND WIFE I �r — _ _ — — / / / / / \ — 1 I I / I JUDIANN E �EORGEVICI� I CD \ / /' / / / 6�� / / / / / / / +/� ' \ — — -656 \ / \ 1 \ \ \\ / I I I I I I I 1 I�� I I I 1 1 � 606 CR TCHFTELD F RM k�D I S\ / / / 1 I I PROP. 24 11.25 RJ FITTING / s \ \ / / / / / / / / \ GARAGE\ \ \ \ \ I STA 309+29 R�'REIDI7407� I � / / / / / / o \ i I , / I \ / / I D81950, PG 210 I I I \ / — ' / / / / 0 / / / /+/ / / PROP. 24" C-900 DR�8�FORCE N1Ali�t 657- — \ \ \ \ \ \ J / / / N 779238 P81 ,PG514,L0 2 I �/ I \'' /' �' / // // o/ / / / +/ / / Or`',/ I \ \ \ \ / / � `/ \ / / \ \ / / / / / / � E 1808855 10/ I to I 1 III / / / / / / // / ��� / / \ r \ / / / . i I I1 t / / PROP. 24 22.5 RJ FITTING 3 \ I / \ `'L Tom\ I \ \ \ — / STA 309+17 / N 779250 \ PROP. 24" 11.25° RJ �O /�/ / /' / / j / / / / / / /+ / / / / / / / /I \ \ \ 171 \ I \ SHECT / / / E 1808851 FITTING )WT ND N 780095 / / 03+0 / FM FM — — 301+ 0 / �/ F \ / 3 + / / /x / n \ \ \ E 1808763 p/302+00 / / / / / / / / / / / I / _ cz — — _ —FM _ — — — — Fl\/1'. 90 8 / / / / / / / �M / \ \ - ► 0 \ \ Fn� / / o + 0 / /' � LOD \ \ \ LOD — LOD — LOD — CO p / i CODi� i / / ///// �_ '— \ --- Oa 0 D --Cr LO� \ \ / o — LgD- j �' // j / // — — I _ \ \ \� i \ \ _ / LID 1 7 % gO� /� L1 L 1 SHED 1 — / 1 I PTA P. 14'� 45 RJ FITTING / /i �'— \ \ \ \ \ 5 / / / / / %- LdD / I \� Imo\ 7 \ / // // // / M S 30 9 / // / ---- \ O; N p 7j / / // / / _______ _ I \ I \ 6a$ N78CO45 / / /// // / / / �� \ ------ \ I I 1 tlI E 180882 j/ }/ j/%6 jab i// /i///// — H � -- — ---- -- �O`Oo \ I E�2luvfiTTENT g 0 — STREAM \00i6 / / / 6 / /// / /_ 00 GENERAL NOTES: CONTRACT SHEET 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY 10 OF 43 SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER SENSITIVE INFORMATION MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN Not to be copied Or ALIGNMENTS. distributed without the KEY NOTES: express written permission of the City O LIMITS OF DISTURBANCE. Of Greensboro. 2O DEMOLISH FENCE AS NECESSARY TO INSTALL FORCE MAIN. OPDUE (NCDOT PROJECT REFERENCE HE0004, I , PROJECT NO. 499797.1.1), WIDTH VARIES. PDUE LINE , IS LIMITS OF DISTURBANCE.em.,A[; ONCDOT REVISED RIGHT-OF-WAY LIMIT. NCDOT PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1. O FUTURE CONTERRA FIBER OPTIC. NOT IN \ CONTRACT. City ofGree oro a round Locales I or I e uests OFUTURE NCDOT ROADWAY PROJECT WORK. NOT IN COG Water es o s e 73-2033 ? fj CONTRACT. GDOT Traffi Si a _ _ _ 73-2606 N) COG/Guilf rd Co. Telecom _ 73-2084 0FUTURE DUKE POWER POLE AND GUY WIRES. NOT COG Water upply - - _ -- _ 73-5855 '07 IN CONTRACT. Tanks/Tre tment Plants I tJ j GDOT Stdrm ter _ — — "373-2569 O�8 UTILITY POLE TO BE DEMOLISHED. CONTRACTOR IS 0 RESPONSIBLE FOR COORDINATION WITH DUKE \� ENERGY FOR REMOVAL OF POLE AND METER. N P D E S l I General Permit I Applies O I PROP. 24" 22.50 / / // / / / //••'� // / / / 600 / / 'G`ARAGF } Cn�I I RJ FITTING STA300+55 N 780084 E1808770 / / / ' // j /%/// / ///' / �'/ / // / �' �'� I~ — ��\ \ \\s�i�\ \ \✓ / / / / / / tp^ / / / / / / }/ \ / / \ \ 6 / /// / / / ////�� / // - / / // /"77116/ / / / --- \ \ \\ oo \\ \ gw! / \C�\ 0088E (P-05805C-06) ' \ \ I \ \ \ \ \ V \ / / l ALFRED M. CRUTCHFIELD AND iD087 (P-05) / / / 688 j / \ oo \ \ / V/ \\ \ \ ' / / / / / l /� / l , WIFE, / / `� \ \ \ \ \ \ \ / \ \\ J / / // // /l / // / CAMELA 8. CPUTCHF / RCL,R�IDA 1097111 �j / / / / 6g0� ' ' \ \ 5536 O \ 1 _ / l / RC R ID 81093 2216, PG K116 / / / \ sy� T%'�` �D D 1 " l 4i P91 / / / _� �\ ��69-11���O�11� D82740,PG17/ � Eq LU J U Q I O1.0 Lr) o z + L O I N ~ CD a Q N�� z 73 i / / / LLJ N IL m co ° It + + + N U CDT z o o o co LO co co It H :;t I H z H Naco Nco Wco Q 4 ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1% OR GREATER - PROFILE OVER 24" C-900 DR-18 FO CE MAIN EXISTING GRADE 24" C-900 DR118 PIPE ALL PIPE SHALL BE INSTALLED ON A POS — _ _f SLOPE OF 0.1 % OR GREATER 301+00 302+00 303+00 304+00 305+00 306+00 HDREngineering, Inc. REVISIONS TYPE CONTRACT CONTRACTOR of the Carolinas NCBELS License No. F-0116 ROADWAY ChaotchNc aiozzo7s00 ziZ4 SEWER 2022-013C 704.338.6700 REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK / / c� z i= F_ LLI LL_ a_ ` a (I') N Z C t g +o N rn o z o o c5 Q r Q IM U) N U) INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW PROP FINISH GRADE 307+00 308+00 309+00 AS -BUILT I AUTH. DATE I WATER AND SEWER PERMITS (D z n o + 0 N � N Q N C0 i DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 O HORIZONTAL SCALE IN FEET + 10 0 10 20 O M 690 VERTICAL SCALE IN FEET Q H U) M 670 M 650 640 630 620 \ C A R p�'%,. �` 037518 LU 610 12/20/2023 Q JOB NO. P-05805C DESIGNED 8/2023 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED K— CITY OF GREENSBORO 04C-06 WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension SHEET NO. 24" FORCE MAIN JULIAN AIRPORT ROAD AND US HIGHWAY 421 PLAN AND PROFILE 10 OF 43 STA 300+25 TO STA 310+00 FITTING WW2SBW- - 0088E (P-05805C-06) OO ALFRED M. CRUTCHFIELD + - PROP. 24" GATE VALVE \ \ \\ \ \ \ mI \ CAMELA BD WIFE, FCHFIELD IJ STA 310+57 2 \ \ \ \ \ \ \ \ \ \ \� \ \ _ \\ \ N \ I 5536 JULIAN AIRPORT RD REFER TO SHEET 04E-04 CID- - _ _ - N 779129 O N,+\\ \ \ \ \ \ \ \ I RCREID 81093 FOR EROSION CONTROL / _ — — - E 1808921 _ \\\\\\\6 ID8 2740, P617sCo/ -\\\ \\\\\ ss\�� I o mow\ I------ �' PROP. FORCE MAIN + \ \ \ \ \ > `- _ = 1 _ j 4"COMBINATION \� +\ \\\\\ �,\\\\ �` IIx N \� ---- 651— -- -�— AIR VALVE W/ 6' MH STA310+69 \ \ \` s� \ �- --- 1I �I \ \�L �� \ \�x�x / \------ 652---------- \ \ ��----653----------- Q— / 2s E 1808928 \ \\ In �1 \\ S+ \�\ GRAVEL \ \�\ \ \ \\ \\ \ \\\ \ \ ��---654--------------- 0/ —655� �656--------------- \ FM-------------- -� / Looms — Q \\ \ \ \ \ \\ \ \ o- _ OO \ g \I \ \ �\ \ \ PROP. 24"22.5 RJ FITTING 7 \ - � Q \ \ ems\ \ \ \ \ STA 314+92 i \ _( I \ \ N 778730 Q C 4 � � � \ OPEN CUT AND PROP. 24" 11.25' RJ FITTING O� S - j - - ��I \ \ E 1809095- 01 L %�� Fji,1_ 3XOp Q/ s \ REPAIR GRAVEL _ _ - _ - - \ 1 \ �p 6_ - - � I j� GAZ I G STA 310+85 *�$ \\ 05 �O (E5 \I \ \ DRIVE (3.70 TON) \ _ - \ - �- - - 0 93 PROP. 24" �900 DR-18R�CE,IVIAIA� vi co LOD a \ n \ \ L \ \ LOD 317f► 00 F \ I / o' II L. 1 `° co 316+00 FM FM 1 \ �O\D v yOD I I I I N \\ o \ / \\ I i ' TREES I \� \ \ j �' - - \ / EE FfM 15 jv0 / F / FPVI �OLOD �\ LO� } \ \ \ \rn I 10) N � � =R _ I \ L T1 /� v/ / _ - 9 / I / ` / / I I / / / - OD�� LOD �^ \ \rn rn N ��o \ °�° 1 1 \ \ x \ x—x LOD \\.\ // / �/ e� --- -�#4R � '�/ /)`o -- \ �—__ -- �x�x III \ I \ �fR \ �M�-- o x TREES rn/ ry-- _�� / ��!! / / / / f / 6 _x—x�x-------FOC -------_—_--_— --_-- /�F�/////// x� ( x�x/ x / x_ ES -- -__-=- - _ �- __ -_ i �/ I 'I x�— x�—/ / / a THE - - FOC— roc / Focy Foci F��—FOClFac—��- ��x �L �D— , FO N ic S„w_sew wiR F _/_/ / _s4 -- -----------___ — _ —x�x —Ntl — - / \ x x� _ - -_�� - ice' =65 - --- -----=j-=-- 6 ---- ---------_--- — --------- O - - O - - - O 690 cY - H I U) i 680 670 ..E 650 •�1 630 Z O Q Z m O U O z LL 00 + N C:) Q N (n I INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW PROP FINISH GRADE PROP. CELL TOWER ,ACCESS RD, - " 1 -F _-'r PROFILE OVER 24" C-900 DR-18 FORCE MAIN EXISTING GRADE w \a LU L L0 Z m (D M Z OwO� W� 12� rn o + to 'I:1- _ N M — N Q N (n GENERAL NOTES: CONTRACT SHEET 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY 11 OF 43 SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. SENSITIVE INFORMATION 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN Not to be copied Or ALIGNMENTS. distributed without the KEY NOTES: express written permission of the City O LIMITS OF DISTURBANCE. Of Greensboro. OPROVIDE 2'x2' CONCRETE PAD AROUND VALVE BOX. OPDUE (NCDOT PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1), WIDTH VARIES. PDUE LINE I , IS LIMITS OF DISTURBANCE. , ONCDOT REVISED RIGHT-OF-WAY LIMIT. NCDOT ' PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1. OFUTURE CONTERRA FIBER OPTIC. NOT IN CONTRACT. City of Gree oro a round OFUTURE NCDOT ROADWAY PROJECT WORK. NOT IN Locates I or I e uests CONTRACT. COG Water eso s e 73-2033 OFUTURE DUKE POWER POLE AND GUY WIRES. NOT GDOT Traffi Si a _ — — 73-2606 COG/Guilf rd Co. Telecom _ 73-2084 IN CONTRACT. COG Water upply _ — — — — — 73-5855 �I, Tanks/�Tre tment Plants O FUTURE UNDERGROUND POWER BY DUKE ENERGY. GDOT Stdrm ter _ — �373-2569 NOT IN CONTRACT. ONCDOT REVISED LIMITED ACCESS LINE. NCDOT N P D E S PROJECT REFERENCE HE0004, PROJECT NO. 499797.1.1. General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 O HORIZONTAL SCALE IN FEET + 10 0 10 20 O N M 690 VERTICAL SCALE IN FEET �U) 670 M. 650 640 630 620 1 1 1 1 1620 CARO,,,. ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1% OR GREATER I I I I I 311+00 312+00 313+00 314+000 HDR Engineering, Inc. REVISIONS of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 zi2 3 4 704.338.6700 REVISED PER NCDEQ COMMENTS 100% SUBMITTAL 315+00 316+00 TYPE CONTRACT CONTRACTOR ROADWAY SEWER 2022-013C WATER SIDEWALK 317+00 318+00 AS —BUILT I AUTH. DATE I WATER AND SEWER PERMITS 319+00 JOB NO. P-058057 DESIGNED 8 2023 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED JLAL 037518 = LU 610 .,12/20/2023 Kr I - CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension 24" FORCE MAIN US HIGHWAY 421 PLAN AND PROFILE STA 310+00 TO STA 320+00 04C— 07 SHEET NO. 11 OF 43 GENERAL NOTES: \ ` 1 CONTRACT SHEET 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY 12 OF 43 \ \ SPATIAL DATA CONSULTANTS, INC. AND BRADY \ / SURVEYING COMPANY, P.A. DURING THE WINTER OF 0089NE (P-05805C-O6) � � 0088E (P-05805C-O6) — \ T 9NE (P BATTERY J 2015. SENSITIVE INFORMATION ALFRED M. CRUTCHFIELD ti 0090NE (P-05805C-06) 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURING, INC. i AND WIFE, 1 TOYOTA BATTERY / _ MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN Not to be copied Or \ RC REID 75456 MANUFACTURING, I C. � — — � p CAMELA B. CRUTCHFIELD \ I / ALIGNMENTS. 5536 JULIAN AIRPORT RD DB 2810, PG 1704, T PARCEL 40 RC REID 75455� — distributed without t h e RC REID 81093 \ ` \ \ PB 40, PG 18, TRACTI I DB 2810, PG 1704, (1) PARCEL 62 / D82740,PG17 \ � P840,PG18,TRy(CTII / / KEYNOTES: express written REFER TO SHEET 04E-04 permission Of the City FOR EROSION CONTROL 0 LIMITS OF DISTURBANCE. Of Greensboro. FEMA1%ANNUAL FLOOD HAZARD AREA \ — / FEMA 1 /o ANNUAL 4 a 1 PROP. 24" 22.5° RJ FITTING 4 2 LINE. CE ALONG EXISTING CONTROLLED ACCESS STA 323+93 / FLOOD HAZARD AREA O ` I N 778184 I \ E 1809810 PROP. 24" 11.25° RJ FITTING O FUTURE NCDOT ROADWAY PROJECT WORK. NOT IN CONTRACT. � STA 324+53 O, \ PROP. 24" 11.25° RJ FITTING N 778131 (32111 E1809838 STA 325+52 ' \ O4 FLOOD PLAIN INFORMATION PER FIRM PANEL 8707, N 1 MAP NUMBER 3710870700J, EFFECTIVE DATE co \ \ 1 N 778051 _ _ 1/2/2008. FLOOD ELEVATION EAST SIDE OF US Q / E 1809896 O HIGHWAY 421: 614 NO ADDITIONAL 1 % FLOOD F- - EX R/W LINE - - - - - - EX R/W LINE _ - - O HAZARD AREA IDENTIFIED IN THIS LOCATION. -- - -- -- -- -- - -- -- e 05,--, OPEN CUT �—--__O5 NO NORTH CAROLINA SURFACE FRESHWATER CI coof',Gree or a round PROP. 24" C-900 Q ies I or I e nestsLOD -- LOD LOD D \ � 01 DR-18 FORCE MAIN PROP. 24 C 900 DR 18 FORCE MAIN CLASSIFICATION EXISTS FOR STREAM S D 134 A. �� LOD — _ i — _ - — — — _ I COG Water eso s e 73-2033 LOD;— _ _ _ _ _ _ — — _ 2 / ,, �/ _ — — — _ — — — _ _ , . / / / / — — — 6 NCDOT REVISED CONTROLLED ACCESS LINE. �N0�6_ = fj35 = — — — — 6, 6' 3 00 63 V v 4� 1 rn // / _ _ = 625= = GDOT Traffi Si a - - - 73-2606 — _ — _ _ 6 '�634 �� O 1 o. j j = _ _ — _ _ — — _ �� �\\ / ( / _ — — ~ ` _ _ _ — — — — _ _ y NCDOT PROJECT REFERENCE HE0004, PROJECT NO. COG/Guilf rd Co. Telecom _ 73-2084 � �40 639 63 F FM F J / l / I l �e i �/� — -629- _ _ — — _����� \� / // // �/ / / / // / =1 \ — — — — — — — — — \ \ 499797.1.1. COT Water er pplymenPlants -- - 173-5855 I ' I / / / / / \ \c \ / / / / / / — D GDOT Sttirm ter _ - - - 373-2569 FM \ FM %� /J//�// / 6�60� ��'��/ / ��\���\_\ —/ /// / ( l — __ �,� LOD %i��D��\CLOD — �— O7 DOCNO NOT DISTURB FENCELINE ALONG CONTROLLED /��� l L — LOD — L �Op L\O �—\— LOD / ��\ \ / 0 — — — 2 5+0 7 O L� D� — --�� / / 0 — � p O �� �/ �� _ — , 629; \ =6 �` s���� s� W I W I I M '°' �o- 2 �29+00 N P D E S �— — — — xx x—x xx—x x— x x r / h p a X> x % \ 6+ E� 1 +? \ 5r �\ 49 1 W3a8+l�lJ I I f0 �O 6 6 �642 �M �``� 65` �'S / 6ti8 / / �`L / / 62 62. -x�ILL \ \ \ \\\ \ \ \ \ OU o 327 u® \\ \ \\ I I "1 r -;�-�� --- — ~------�._ ' ^' \\���\\\ \ F�M \ IFM — �M \ \ FMB FM X�xJ-�I— 4 x General Permit L.,=7�x UM€' ��_ _--_---_-_�__�_�—_�_-_-_--- �wP - - \ `�i �� \\�� \ \_ \�\1�rq\ ,(�[� I 6 3_ 2- z r _ — — —a 15 — — — _ — - — D — — —�r�0 i% 1 \ \ ' nn 'd"" `�a� r-�"�t�-'.. �x- x— T� — 4 LLJ _ ` �C\ _ C _— _ ——_— _— — — — — — — — — — _ J �x x_x—x—� p1 A O O �� �!�' z--_= = _ _t x-max v 5 / �� �� --- �_� 630 \ �'o / w ' co ca 6 fO------------ 620— —�__ q0— - —�i — / / / i — cn J- \� �\ - - -_-- - ---- - ------------ -=_ __ -�_ii6`Zi�/_/,� �i i =--__ ��_ _-Hd�f=625.9/ �j/ L � / / � I \ __---- __ - --- _ Applies _2�-%630�'�= 63 -----�i/I�r4LR �/ ' --- -- — -- _ _ _ 635 - _ _ / i - �=� _��-_�_---------------- ICY - DISTURBED AREA = _ _-- __ � - _ - =__ 14.76 AC ---6__ GUAR -_-__ --- __ � 3 _(LU RDRAIL' _ f - - - - _ _ - _ - ---- _-------- _------_-----------_-------------------------------------------------- ------ _ ------ - --------------�-------- PROP. 24" 11.25' RJ FITTING\ / \ STA324+73 GIS DISCLAIMER I /(INORTH �� / \ N 778114 1 \ \ \� / Objects on this map shown - _ _ — _ _ — _ _ _ _ _ _ — _ _ _ _ _ with a dotted linestyle were --- —_-- --- � � ___ — —_— _—_-- � � — ----- _—_-- —_-- � �------- ----- ------ not surveyed, they were ----,— _----- _ _ ---_% --- _--_ _�� __—� /--_ _ _ _ _----- ------------ _ _--___---_—____----- compiled by photogrammetric methods, available on the 650 _-- --_ _----- _—_ _�5� L/ ---- _-- -- — 640 ------ —__--_----_—_— ------ _ ---- —_-- —_-- — _ --__-- _-- -- _ _ —---_—_-- —___-- _—_--- _—_--- _ _ _ _ Geographic Information - �_--_—IGI _--- _--- --- — — — — � � — — -f—-------_------ _ — — - ----_— _--------_-------- ----- _ _ _ —_ —---FLTJME System (GIS) software used —� _---- _----- _------_ --- _� _----- — ---- __------------- _ — _ _ ---___ by the City of Greensboro. _E-M6�7E, �U ____ _ — ----- ---- --- —�_ —W1 TH OI O pl - N 670 Q H G7 I 660 650 I 640 630 I I 620 I 610 600 I 590 LU z_ JI al HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 PROFILE OVER 24 C-900 DR-18 FORCE MAIN EXISTING GRADE z \ w a INSTALL 24" FORCE MAIN AT A DEPTH coo REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW PROP FINISH GRADE z M U Q m U) ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER 321+00 322+00 323+00 I_ — LL of tT ° + Lr)CO N M Q N (n I � � z z I + + N N N CO r Q I N N CO C — M + N cM Q z r + + to N N � Cl) 4 N U) � — — 24"IC-900 DR18 PIPE Q A L PIPE SHALI=--SE INSTAL ON A POSITIVE SLOPE OF 0.1 % OR GREATER 324+00 REVISIONS 325+00 REVISED PER NCDEQ COMMENTS 100% SUBMITTAL ALL PIPE SHALL BE INSTALLEP ON A NEGATIVE SLOPE OF 0.1 % OR GREATER 40 0 40 80 O HORIZONTAL SCALE IN FEET + 10 0 10 20 O CM co 670 VERTICAL SCALE IN FEET Q H 07 650 640 630 620 610 600 S s'Ro� 037518 = z 590 TALLED 12/20/2023 = `�•'• ALL PIPE SHALL BE IN ON A POSITIVE SLOPE OF 0.1 o OR GREATER '�.,, ;NEr1 w,�p:�`� U 326+00 327+00 328+00 329+00 TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS ROADWAY SEWER 2022-013C WATER SIDEWALK JOB NO. P-05805C DESIGNED 8/2023 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED K— CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension 24" FORCE MAIN US HIGHWAY 421 PLAN AND PROFILE STA 320+00 TO STA 330+00 04C— 08 SHEET NO. 12OF43 ° �\ CONTRACT SHEET GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY 13 OF 43 / \ \ SPATIAL DATA CONSULTANTS, INC. AND BRADY 0090NE(P-05805C-06) 0091NE(P-05805C-06) \ �� 0091NE(P-05805C-06) 0091NE A (P-05805C-O6) I SURVEYING COMPANY, P.A. DURING THE WINTER OF TOYOTA BATTERY TOYOTA BATTERY ��� / 1 TOYOTA BATTERY TOYOTA BATTERY i 2015. MANUFACTURING, INC. MANUFACTURING, INC ¢ 0 , MANUFACTURING, INC. MANUFACTURING, INC. RC REID 75455 RC REID 75456 oj� RC REID 75456 RC REID 75460 4 SENSITIVE I N F 0 R M A TI 0 DB 2810, PG 1704, (1) PARCEL 62 DB 2810, PG 1704, (1) PARCEL 40 P REFER TO SHEET 04E-05 p_ 2. DEFLECT PIPES AS NECESSARY PER p� 1� 11/ � DB 2810, PG 1704, (1) PARCEL 40 DS 2810, PG 1704, (1) PARCEL 99 PB 40, PG 18, TRACT 11 PB 40, PG 28, rRAcrr �0 ti� P8 40, PG 18, TRACTI FOR EROSION CONTROL Pe. UNREC-2016 (60' RIW I MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN Not t0 b e copied or ok BROWN'S MEADOW ALIGNMENTS. — _ distributed without the KEY NOTES: express written / permission of the City / \ 0 LIMITS OF DISTURBANCE. of Greensboro. C4 EMA 1 % ANNUAL / O PROVIDE 2'x2' CONCRETE PAD AROUND VALVE BOX. \ FLOOD HAZARD AREA / \~ / - O FUTURE NCDOT ROADWAY PROJECT WORK. NOT IN CONTRACT. PROP. 24" GATE VALVE I I v O PROP. 24" C-900 DR-18 FORCE MAIN STA 332+50 / \ O4 FLOOD PLAIN INFORMATION PER FIRM PANEL 8717, CD INSTALL 10' BEHIND N 777649 O J JEE PROP. 24" C-900 DR-18 FORCE MAIN ��I 1I 9 LF OF O MAP NUMBER 3710871700J, EFFECTIVE DATECONTROLLED ACCESS FENCE iINSTALL 10' OFF + 1/2/2008. FLOOD ELEVATION EAST SIDE OF US O E 1810465 \ / w ,� \M 6 aUJ RIGHT-OF-WAY \ d.HIGHWAY 421: 611. NO ADDITIONAL 1 /o FLOOD U t 36 STEEL CASING PIPE, OoEX R N N EMA 1% ANNUAL ERI�4TTENT�0.375" WALL THICKNESS CY) HAZARD AREA IDENTIFIED IN THIS LOCATION. __ LOOD HAZARD AREA �EAM 10 /W LINE S-C-18311 _ 1 '� 5 NO NORTH CAROLINA SURFACE FRESHWATER I��-}{�E E �- E rt- �T- ��-EFE E E E E \o\ \ \ \ \ \\ \ �_ _ = E E E \ ° 6 CLASSIFICATION EXISTS FOR STREAM S-C-183-1. City of Gree oro a round - - ._\ \ \ \ �� \ a+ \ s \ \s - -- -s 6 `�2c E E E 1 Locates I o 1 e uests � 6 cn FNw i'"6' \ \ \ j \ \ c� ,�\ \ ?\ �_-'623-� 22 \ \ \ \ E�s w6+\ S -�— st _ 1r �'��LOp-- I I ao 1 \ \ 'P'p'�El '� �� - 0333+ 0 `�C� \ "'� �\�-� - i 1� \ \ \ \ \ I O 6 TEMPORARY CONSTRUCTION EASEMENT LINE IS + I \ \ \ —� \ \ \ \ \S§` _ \ \ \ 3 � �` \ \ \ \ \ \ \\ �111I 0 COG Water eso s e 73-2606- s35- 1 0' 1 1 \ \ \ \ \ \ $�?\ 00 FM FM\ \� �� .e��.�... \ \- / /70� �,���s 6 \\ \ 6� \\\ a� \ o I y o I Y I E LIMITS OF DISTURBANCE. GDOTTraffi Si a -73-2606s3s__\ \ \ F F\ \ \ -� ��M � � �-�\� + � O \ CO \ �' oll � �\ v �� / COG/Guilf rd Co. Telecom — 73-2084 13 1 00 \ \ QQx=% �- .�� \--- � �\ \ FM - - \ T� �' I r 6i ° -�sgp s_ �6, 6, \ "�- "�--% \ \ _ _ _ _ _i �- \ I-� \ 1 / \\ 6+ v _ �9 O DO NOT DISTURB FENCELINE ALONG CONTROLLED COG Water upply ----- 73-5855 = - x \ �\� ACCESS/RIGHT-OF-WAY. Tanks/Tre tment Plants 00 -M � ��C�� L �� S A \ �� \ ats \ \ r, \ o \ �cP \ \ ��ir \ o�v' \ \ sSo \ \ s2 \ \ \ \ s2 \ \ \s? \ \ 62 �0%"'z WIR 7FEN%C �T- - T / , - ill— �� X�XY"— \ 6, 6'� 64 49. \ \ \ \ \ \ \ . S S \ \ 2 p _ z = \_z x_ \ \ �f- r \ 6 3 GDOT Storm ter — 373-2569 _ J- -�X �nIIR FE�EX' C X TROYLED 1 \ \ \ \ \ \ \ \ \\ \\ \ \ \ \ \ \ \ \ \ \ \\ - EX� NE s x �'� %Z \ / / � � \ �O \ �A �+� �o I /PID92 __� 8 RIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. wow 7l 1 I 1 w�oDs \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ / / 7 8 s22 \ S � I IFk� \ y . X=1 1'0 1 641- _ - - - - - / \ \ \ PROP. FORCE MAIN \ \ \ \\ \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ` - / / / / / \ \ \ \ \ \��t• \ N� \ \ \ ' \� Y= 7 71,9 S N ED- / \ \ \ \ 4" COMBINATION \ \ \ \ \ \ / - \ \Y O EDGE OF PAVEMENT IS LIMITS OF DISTURBANCE. _ _� \J�\i�\�\ \\\\\\�� \\ \ Iv\ \�\\\ dr�x�-r� y\y•Z=1�i1.1� , NPDES _ =AIR VALVE W/ 6' MH =_ - � �/ i / � � ) � \ \ \ 1 � � / i WOODS - \ \ \ � STA 332 60 - j /i / / / \ \ \ \ \ - - -/ _ \ . \ \\ \ \ CT 183 3 + �% _ i� / i \ \ \ / _ _ \ 1 DO NOT DISTURB WETLAND OR STREAM. General Permit _ _--------_ _----_- _ N777643 --_ _'� /����'��� -_ \ \ �� = -- _ / PROP.24"22.5°RJFITTING k_ _--- ------- �-- E1810473 - --���-_� \> `---- + \ 1 \ \ I /1i11 / �� J� _ _ _ - - - - s25 STA 338 54 y g W - _--_--_-___---- -- -_-- - _- --_- - --- - - - _ N777265 \ \ i I 1 / , 02'\ // \\ w Applies J�------- - - - ----- --__ _—_ —°-_ - __--_-_— ---------- -----� ----- E1810931 -------__----- FLUME FS --__ --__-_ ---_-- --___ \ \��\��- _ ,- -__- - _ _-_----___ _-_-_-____ __-_-_-____ - -__-_ - ----_____---_______----_-__,_;____ �_- -_�� \\I � DISTURBED AREA = - ��_ ��- -----= -� _ — -___ -�--- _ —1=- — — --- -------_ _=- ,14.76 AC aTQ AD1 Qr. J r\ N ___------- _----- —__—___-_----_-_-_----__-_-_---_----_--_ _ _ —4'�� __-- __---- ___------ ---------------------------- _ ---�_ g Objects on this map shown ----------_---- ---_ --- _ — 630 — --�— ------------ ------ — — — — — — s25 - — — _ _ --_ -----t- with a dotted linestyle were --- ---- --_ — ---- --_------\------------_ _ _ — _ _ 625= —---------------------�_ _ — not surveyed, they were _ — — ------------------------ __ _-/---- �\ compiled by photogrammetric -Z-- _ ---- c_----__--------------F — ��-------------------------------------------- 1---- ��� I methods, available on the - 2�-rTs _ ___ -� zz:___----- _-----_----- —--I�t,�� _? __� �I Geographic Information 'd W _IUV -E2LL75 -FOR=`g23-6�- - - - - - _ _ _ _ _ 20 �T -INFO 812`58' \ I System (GIS) software used J ---- --- --__ __--- -___177V=6_ I'll, \ _ 1 by the City of Greensboro. - ��- ------------------ -_-_ 625 - _ _ �211$ Q,2�-� -_-TOP=618.9I - ) /� / 1-- INV ZQ RCP O O O co 660 co H I U) 650 640 630 620 I 610 I W 590 580 z J U 5� G 1 I w d a- CV Ln � O z M M W Q m U) z� O(.0 Q� CD z w (0 CD 0 m J CV C'') Q M O> Mo ALL PIPF1 ZSHALL BC INSTALLED O[Ni A DncITIVD 1 nDD n� n o% nD i_DDA DD I I V V I I I V I- L_% 1 1 I- V I V. / V V I % V 1 % L_/ \ L I PROFILE OVER 1 24" C-900 DR-18 FORCE MAIN EXISTING GRADE ui00 d 't I M 24" C-900 DR18 PIP � M Q z w cn INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW EXISTING GRADE Al I DIDDIQWAI I RD IKI$TAI I P:n nKi � KID(_OTI\/D $1 nDD n� n 1I0% nD �DDATI�D / \LL 1 11 1- VI if \LL ✓I_ 11 V 1 / \LLLV \JI V \ I YLV/ \ I I V L_ I -VI I- % 0I VI /V \ 0I % VI %I-/ \ 1 `1 331+00 332+00 333+00 334+00 335+00 336+00 HaREngineering, Inc. REVISIONS TYPE CONTRACT of the Carolinas NCBELS License No. F-0116 ROADWAY Chaott,Nc azozzo7500 SEWER 2022-013C 704.338.6700 WATER 100% SUBMITTAL SIDEWALK BROWNS ME DOW rn LO a0 M N M N Q N U) w a- 109 LF OF 36" STEEL CASING PIPE00 z �M.., 0.375" WALL THICKNESS I (� Q w� m cn All I MIME: CUAI I DC InIC-rAI I Crl rim lILL I 11 L V I I/-lLL LJL I I V V 1 /-ILLL L.;1 V A 11/\r11T 1I /r nl /11"1r /\r w nl /\11 /111r n Trl"1 H r uo I I V G OLVr rz Vr I %o um umr- I r-M 337+00 338+00 339+00 NTRACTOR AS —BUILT 1AUTH. DATE IWATER AND SEWER PERMITS O O O co 660 H 07 650 640 630 620 610 M. z 580 J U 5� G JOB NO. P- 05805C DESIGNED 11/2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET %%, 1 111"4, 037518 01 /24/2023 , c -'0�I . . I NEB .',NE,y1w;�1 K- CITY OF GREENSBORO 04C-09 WATER RESOURCES DEPARTMEN GRMS Phase IV Sewer Force Main Extension SHEET NO. 24" FORCE MAIN US HIGHWAY 421 PLAN AND PROFILE 13 OF 43 STA 330+00 TO STA 340+00 0092NE(P-05805C-06) TOYOTA BATTERY \ MANUFACTURING, INC. RC REID 75460 \ \ 1 FEMA 1 % ANNUAL O DB 2810, PG 1704, (1) PARCEL 99 PB UNREC 2016 ' R/W GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. PROP. 24" GATE VALVE \ FLOOD HAZARD AREA - 1,V0 STA 342+04 \ BROWN'S MEADOWRD) PROP. 24" GATE VALVE 0 RIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. N 777022 22 v STA 346+51 E 1811183 \ ) \ N 776690 22 0PROVIDE 2'x2' CONCRETE PAD AROUND VALVE BOX. E 1811482 \ REFER TO SHEET 04E-05 O FUTURE NCDOT ROADWAY PROJECT WORK. NOT IN ` PROP. FORCE MAIN \ PROP. 24" C-900 DR-18 FORCE MAIN FOR EROSION CONTROL CONTRACT. \ AIR RELEASE VALVE \ INSTALL 10' OFF PROP. FORCE MAIN (COG STD. 211) W/ 6' MH \ \ I RIGHT-OF-WAY Lu Lu AIR RELEASE VALVE 1,+ OO FLOOD PLAIN INFORMATION PER FIRM PANEL 8717, STA 342+16 _ D U (COG STD. 211) W/ 6' MH MAP NUMBER 3710871700J, EFFECTIVE DATE p N 777013 \ o o STA 346+61 6 ILO 1/2/2008. FLOOD ELEVATION EAST SIDE OF US 0+ E 1811191 FEMA 1 % ANNUAL 1 \ N N N 776682 M HIGHWAY 421: 611. NO ADDITIONAL 1 % FLOOD OFLOOD HAZARD AREA _ \� ��O E 1811488 I< HAZARD AREA IDENTIFIED IN THIS LOCATION. \ E E E E E E E E E E E E E O NO NORTH CAROLINA SURFACE FRESHWATER M IIE E—E ESE E lE Q 6 E E E -� y A CLASSIFICATION EXISTS FOR STREAM S-C-183-1. E c~nI E E E I s% . o 0 =4T+'�0 $+�- \�\-� y +0� L E E �c -� -t�s I 1 + \ \ \ I I I I I I I I IFRI \ \ \ \ 6 �r�� �75 O6 TEMPORARY CONSTRUCTION EASEMENT LINE IS E — E E _ _ -\}fj\fir ��js-�i\� + \ \ I I / LIMITS OF DISTURBANCE. — / rp`L1� "� '\�O \ \ \ I I 1 1 I I 1 I ' r r — x�z—-ter-x-i �r� s�� \ \\ T \ z_ Fj�jFi / E E / \ �� I I � ' 1 I �� _ �642 641, \ �6 - -/ i�-� O7 DO NOT DISTURB FENCELINE ALONG CONTROLLED � \ \ \ o � \ \ O\ \ \ - - - �� /� i ACCESS/RIGHT-OF-WAY. �'34 �U�► 7 / / ,ter- 6 \ s \ �� // to o to to r� - - _ _ — wL-NF-- s\ \62\�0\'8, \I\\RI�' APB/i/��IIII�II I INI I I INIIII�III1�\1\\��\\ _ _ WOVEN WIRE FENCE ATE \ \ 2S\ \ \ �\ \ /// I I I`° I I I cO I I I I 1 1 \ \ \ \ \ \\\ \ \ 7_\ V. --- �� \ \ \ \\ �T' ?,� ( I PROP. I I 1 \ \ \\\ \ \ \� — _ — \ \ \ \ \ �\ 9 �y \GEOT Y k I I I I \ \ \ \ WOODS _ 6 — 630 / �\ \\ \\ \ \\\\ \ \ \\\ \ 6 I \\ / / J) STA344+57 I I 1 I \ 1\ \ �\\� ------------- --------\\� \`----����/ / i --- _ \ \ \ \ \ \ / // N776837 l I \ \ �� - --- ------------- __ _ _ IW _ \ \ \ \ 622/_ � �/ 7 --_--- \\\��\�l�l` \ E181135564Q===-== _I WOODS _ _ _-------- / / \ \—�620�= — ��,lz FL _---_—----------------------_—_—_ _—_—_— � _—� _ _630 ____—_ /— --_�� ----— __--____--------------- J�\ -- --------- ----� — 625 -2-4 Ri`F' \\ —_—�—� ------ ---- ---- --------------------------------- _ _----- 625 — —Inv. In 60$OB —-----_----—_--------- � 42" RCP () '---- _—__----- ---_ —� Inv. In 607.43 ------ ----- i� ---- --= — — — — — — — — — — — --— — — — — — — — — — — — — — — — — — — — — — --- -- =--- �\---__------ 625 SIGN ----_ `-------_ 3 \ r`� 630 ` 45IGN-- SIGN �BISIGN -- \ H \ ----- ---------------------- 0 -------------- ------ __----- - --_ _ _ - 0RT __- _ _ _ = — 3 — — — — — — — — — _ — — — — — — — — — — — — — — — — — — — — — — — — —_ — — — — — — — 0� _ _ _ ��` �\r _ _ _ _ — 3 TAR q�p E%� —------------- ----- ----- \ ��— _ —2�.._ —----------� � _ 05, EIP _ _ _ _ --- °y _ N-----_ -S------------- -- -- -_ ------ /SIG ,-------------------- -- __ --- _---- _�4� Rom'— _-----II�V=614-95'_�/ ����'�� �_________�zL-- \�� _---------- ----- ------ _ ----- --- TOP=619:6�'— �� F � - _ ___ J— IIGN \ °s _ 620 — —------� ------ —� E \ i — _---- - r 625 — _ \�\�\\`\ \ // /�— O O + O 660 co 650 630 620 610 590 580 z J U 75 F)l 'ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER - - O - - O + O w - M a 660 LU (n N t9 = O w N N 24" GATE VALVE 0 Q STA 46+51 650 02 z_ / LL w 640 \ PROFILE OVER N 24" C-900 DR-18 FORCE MAIN M / EXISTING GRADE Q / `V U - 630 - — _ Z z \eREEK/ -I 620 \ I �0 I 24" C-9001DR18 PIPE � N Q O CD � co INSTALL 24" FORCE MAIN AT A DEPTH 610 O M (_0D REQUIRED TO PROVIDE A MINIMUM z _ O Q � O COVER OF 4' BELOW EXISTING GRADE COEw w J LL 600 > o � C) w+ Q � �,+ N � Ur co r co `V `V 590 ALL PIPE SHALL BE INSTALLER ON A NEGATIVE SLOPE OF 0.1% OR GREATER ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER I I I I I 1 1 341+00 342+00 343+00 344+00 345+00 HaR Engineering, Inc. REVISIONS TYPE of the Carolinas NCBELS License No. F-0116 ROADWAY 440 S. Church St., Suite Charlotte, NC 8202-2075 00 1 2 3 4 SEWER 704.338.6700 REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK ./`�\ ALL PIPES ALL BE INSTALLED ON I A POSITIVE SLOPE OF 0.1 % OR GREATER W 580 ALL PIPt SHALL BE I STALLED O A NEGATIVE SLOPE OF 0.1 % OR GREATER U 346+00 347+00 348+00 CONTRACT ICONTRACTORI AS —BUILT I AUTH. DATE I WATER AND SEWER PERMITS 2022-013C 349+00 JOB NO. P-05805C DESIGNED 8 2023 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED CONTRACT SHEET 14 OF 43 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. N o rth 8� Carolina , www.nc811.org� Cliy COG Water es7PIonts 73-2033 GDOT Traffi Si_ 73-2606 COG/Guilf rdm — 73-2084 COG Water UP— _ 73-5855 Tanks/�Tre tmGDOT Storm �373-2569 NPDES GeneralPermit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET CARo .�_s•cS i•��/.' 037518 �.12/20/2023 T �NE1w,.ilp K- CITY OF GREENSBORO 04C-10 WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension SHEET NO. 24" FORCE MAIN US HIGHWAY 421 PLAN AND PROFILE 14 OF 43 STA 340+00 TO STA 350+00 GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. CONTRACT SHEET 15 of 43 0092NE (P-05805C-06) TOYOTA BATTERY NOROTH CARO NA RAILROAD ` \ MANUFACTURING, INC. \ HOLDINGS I, LLC RC REID 75460 \ 5990 STARMOUNT RD DB 2810, PG 1704, (1) PARCEL 99 � � \ RC REID 75464 Pg. UNREC-2016 (60' R/W DB 2489, PG 887, PARCEL 32 , \ BROWN'S MEADOW RD) PROP. 24" GATE VALVE STA 350+72 N 776357 2 \ E 1811740 \ \ \ PROP. 24" C-900 DR18 FORCE MAIN ` \ INSTALL 10' OFF \ REFER TO SHEET 04E-06 CONTROLLED ACCESS LINE FOR EROSION CONTROL \ w w 0 PROP. FORCE MAIN + 4" COMBINATION \ , , o O AIR VALVE 4 LO M W/ 6' M H E E E E E E E E E E STA 350+84 E E N 776348 E E E E E E E E E E E E E E1811747 •�E�E—_� E E 3;L5+�0— — —_ �__ 356+00— _ _ 633 — _ —_ — — —0110 — 358+C _ E E E �� -_` �y� T 4+�� ; g35 _/ r,.y - — r i _� _ FAA - — _ 635 _ — — — — — F — — � \ �q35q+00 \ E o' ��� �"'r ' \� \ ��M -- _r �i -638 ---� -_ - _---_ %'^' --_ F'Nr \ \ \ 1, - - FW - - - 8 X- �--- x x X =X - ' —•L-638�_ •—•—• -WOV�iF�E FENCE x \ �z-fix _J 1+00 \ o �D� 38�J- \-L'h E- 38_-_% 638\ 640-� -�\ ___ _ _ _- - _��63 __ 638` -�-I- z r�� -I + F \ \ r? \ � %- _=6 WOVEN WIRE F AQ EX\R%N! _ / _ / / - - - - €�C.-RTW LINE 9 —� - x \�\-��-�'�. / �642--- 64��\ _�// % 640, �� // ---- __---� 640 -- ---643--? ��� \//_�- _`� _ \ \ M I c°bo ;650/\\_—\\\ 5 wooDs 1 I I� I I I I l I/G/j�I \ \ \ _ \ \ \ - /-__- -- - /__ \ --_ — — — — — — ---/ ___ I / )J J- --- - -_--_------------- FLUM1 - ;-------- -------------------- -_ Q V — _ �- =635===--- ---�_- _------__O- -=-_--------� INo _66 635 — I— 0 _ 630 — ---- ------ ---- —�— — �� —-------------_--- _------------- _-- __=---------------- Q_ ---------_ 3LFJ _--------------- -��--------_--_ = ------------- ---- Q� 3 — <��__�_--�_ US 421 (NORTH D) _ Q 247 Q----------- _ — 3-----------------------dJ --- �(1 —_--------------'_ _ ---- �_— -----------------_ —\T------__----------------__— �-�-A�OVE- -- 630 — _ — ----- ---_ ------ _ — — —'964 _—__ -- — — — — — — — -------------- — 630 635 _ —_-- _--_ --_——_--_--_— _ —S—1------------ _ ___---- g40 _ RETAIN DI O O O +� z 680 M O z w It 00 00 U) lb i rn O O O>� M Q� �ry 670 650 640 630 620 J > N I` w + O Q LO M Q 610 `� � 600 z J U I�� 350+50 351+00 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 351+50 II 7 i oz — 352+00 w a- tb N LO M Q z� w U) PROFILE OVER 1 24" C-900 DR18 FORCE MAIN EXISTING GRADE 24" C-900 DR18 PIPE ALL PIPE[ SHALL BE INSTALLED ON' A NEGATIVE'SLOPE OF 0.`1 % OR GREATER 352+50 353+00 353+50 354+00 354+50 355+00 REVISIONS TYPE ROADWAY SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW EXISTING GRADE 355+50 356+00 356+50 357+00 357+50 358+00 358+50 CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS 2022-013C 359+00 359+50 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. KEY NOTES: 1O RIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. O2 PROVIDE 2'x2' CONCRETE PAD AROUND VALVE BOX. O O+ O3 FUTURE NCDOT ROADWAY PROJECT WORK. NOT IN CONTRACT. M Q O4 TEMPORARY CONSTRUCTION EASEMENT LINE IS LIMITS OF DISTURBANCE. ODO NOT DISTURB FENCELINE ALONG CONTROLLED ACCESS/RIGHT-OF-WAY. SENSITIVE INFORMATIOI\ Not to be copied or distributed without the express written permission of the City of Greensboro. North Carolina 8� , www.nc811.org City of, Greer COG Water eso s e 73-2033 GDOT Traffi Si a _ _ _ 73-2606 COG/Guilf rd Co. Telecom _ 73-2084 COG Water upply _ _ _ _ — 73-5855 Tanks/Tre tment Plants GDOT Storm ter373-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 O O HORIZONTAL SCALE IN FEET + I� CO 10 0 10 20 — co 680 VERTICAL SCALE IN FEET H U) I 670 I 660 — I 650 I 640 I I 630 i 620 610 I z 600 IJ 2 I� JOB NO. P-05805C DESIGNED 11/2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED ,,,�111111/1j1, �= 037518 01 /24/2023 , I:� CITY OF GREENSBORO 04C-11 WATER RESOURCES DEPARTMEN GRMS Phase IV Sewer Force Main Extension SHEET NO. 24" FORCE MAIN US HIGHWAY 421 PLAN AND PROFILE 15 �F 43 STA 350+00 TO STA 360+00 J \ REFER TO SHEET 04E-06 GENERAL NOTES: CONTRACT SHEET 0093E(P-05805C-06) O FOR EROSION CONTROL 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY 16 OF 43 'NkRTHCAROLINA RAILROAD SPATIAL DATA CONSULTANTS, INC. AND BRADY /-l4OLDIN6S I, LLC FEMA 1 % ANNUAL SURVEYING COMPANY, P.A. DURING THE WINTER OF 599 STARMOUNTRD FLOOD HAZARD AREA TRANSITION TO 10' OFF TOP OF LAKE BANK R REID 75464 2015. \ DB2489`RG17,PARCEL 32 SENSITIVE INFORMATIO \ PROP. 24" C-900 DR18 FORCE MAIN 2. DEFLECT PIPES AS NECESSARY PER INSTALL 10' OFF \ TRANSITION TO 10' OFF TOP OF LAKE BANK MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN Not to be copied or / \ RIGHT-OF-WAY FEMA1%ANNUAL / ALIGNMENTS. distributed Without the PROP. 24" 11.25' RJ FITTING PROP. FORCE MAIN \ \ \ \ \�� \ - - FLOOD HAZARD AREA (VERTICAL) I \ �\ AIR RELEASE VALVE \ \ \ \ \ \ \ - _ - - - - - �� /�/ / STA 360+47 1 1 \ \ �\ \\\ \ \ \ \ \,\ \� ` _ O / /� KEY NOTES: express written (COG STD. 211) \� \ 605 _ _ _ permission of the City N 775521 \ \ \ \ I W/ 6' MH \ \ \ \ \ \ \ \ _ _ - - - - - - - \ \ / �� } 1O RIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. p E 1812240 \ \ \ \ I \\ \ \ \ \ \�\ - — — — — _ �� \ �,j/ /�/ i �' �� / of Greensboro. \ I I STA 363+89�_ 1 \ \ \ \ _ _ O r O2 PROVIDE 2'x2' CONCRETE PAD AROUND VALVE BOX. N 775212 \ \ \ \ \ \ i9 \ = / \ DODSONS LAKE //j / // // / / / �� O 0 PROP. 24" 11.25' RJ FITTING \ 1 \ \ ` \ `� E 1812386 \ \ \ s \ \ \ \ \� _ _ \ \ \ \ \ / + (VERTICAL) o / \ 1 1 \ \ �\ \ \ \ \ \ \ `o \ \ \ - - _ \ \ \ \ \ \ \\ WE 601.2 // / (P // /� / /o/ /i �'� O O STA 360+57 `v h I \ \ o \ \ \ \ _� — / _ \ \ \ \\ \ \ \ P—A-183-1 �j / ro // / /,- /) / f� O3 FUTURE NCDOT ROADWAY PROJECT WORK. NOT IN M N 775512 / �,' I \ 1 1 \ \ \ 1 \ \ `� \ \ \\ \ \ _ �' -` \ \ \ \\ \\ \ 1 \ // / / // �/ /�� U / M CONTRACT. /w /�11 a I \ �' \ \ \ \ \ \ \ \ \mow �w - — — \ \ \ 1 \ / /°/}/ �/ i' H Q E 1812245 I / ) �; I 1 �0 1 \ U - - _ - \ - 0 / / / "N 1 } J �. \ \ \ \ \ a - _ ` - - \ \ \ \ \t \ I n / / / / / /o / �� 4 FLOOD PLAIN INFORMATION PER FIRM PANEL 8717, \ 1 1 "�\ / / / �5 MAP NUMBER 3710871700J, EFFECTIVE DATE Cn� 10 I / / I N I ro �\ \ \ \ \ \ \ \ \ �� �N -�\\\\ \ 1 1 I \ 9 �/ RI4RA// / /I/�o� / 0 6 ,e / / / N i (o 1/2/2008. FLOOD ELEVATION EAST SIDE OF US INTERMITTENT ' / / / / a I I 6 \ } y \�\\\ \\ \ \\ \\ N ��`--� \ \ I I \ } \\\ /� / / / �� �� / / // /�.. o STREAM / \ \ \ \ \ E / / �'—b�- HIGHWAY 421: 608. NO ADDITIONAL 1 /o FLOOD / N �` E E E \€-� - - \ \ I 1 - /E E �— E HAZARD AREA IDENTIFIED IN THIS LOCATION. E SEA-1E E E / E E E� / Fes+ E ��`\ \ \\ \ \�� �-. \ ) 1 1 \ I I� \ \ �•,�/l \ 1 / / / � L �`— r� r �- , �L. / \ \ \�� `� � � _ �5 NO NORTH CAROLINA SURFACE FRESHWATER + + \� \ - -� F 3 + ��7 CLASSIFICATION EXISTS FOR STREAM S-A-183-3. CHy of Gree oro a round T // / 3b'3�0 / �� \ \ \ - FM- - - - - _ F M _ - F - - M FM Locates I o I e nests FM / :F / / FM/ / / /M FM -F FM \ - M\ - --.-�,�-_� - - -� �. - - > > ' �'x/ O COG Water es s I 73-2033 6 TEMPORARY CONSTRUCTION EASEMENT LINE IS / � \ \ 6, �o+ 4" 6P ;�-�J LIMITS OF DISTURBANCE. GDOT Traffi Si 73-2606 io a, a+ a+ s �s 6 6' a� EEC. R V�l LIN \ s.7 �� _ 6p / / �v626 r` y N N ? 2 �G �i9 c`D ifl \ S_\/—��' O` � \ �� �i` I v.�l 6 3.1 I co COG/Guilf rd Co. Te73-2084 1 � \ � ETLAND H /�P�24'AMP / / / / / 1 - - \ \\ \\ \\ \ �\ \ \ \ i \ \ I 1 ) ) 0 jnv. ut 0 \ O7 DO NOT DISTURB FENCELINE ALONG CONTROLLED COG Water upply _ a 73-5855 �3 1Ind. In 611.37 / / / / �i 7 �� \ \ �) I ) / /���_�_--�AM/I ---ll��\ACCESS/RIGHT-OF-WAY. Tanks/Tre tment PlanE :WETLAND \\ v. Out eO.45 //— /iL `��_77—�605 GDOT Storm ter _—73-2569 it / / / / / / - - - PROP. 24 GATE VALVE i—� - - �- 3 1 � � / / / � � \ \ �� � _ �� � � �� � � ` �_� � In 0 O8 NORTH CAROLINA SURFACE FRESHWATER PO D 24" MP / / / - - - � � STA 363+76 � �` UMW -� �In 6 1.20 / / / / / / — - \ �� - -- \ \� C'9NC `RETE \ \ \ _ 5 / LU CLASSIFICATION FOR DOTSON'S LAKE P-A-183-1 AT / / / / / / / N 775223 O \ _� -�_ - - __ _ _ _ - I_Z THIS LOCATION: WS-III. DOTSON'S LAKE IS A PART \ \\ _ / _ _ _ _ _ _ _ _ _ OF THE CAPE FEAR RIVER BASIN. 11.1 \ - -_� � � _ � � - E 1812380 � \ � OPEN CUT AND REPAIR � \ \ \ \ _ _ _ _ - - - �6- - _ � - / � � / � i Inv. t 61 i= f/ j / / // / - \ \ \ \ �\ \ GRAVEL DRIVE FULL WIDTH \ \ - - - _ - - = - _ / /- - J J N P D E S Z _ - - _-�--°'' e-+'= - - WQB6S _ - - - TREES _ / b'L6.75� \ STA 364+65 TO STA 368+53 \ - - _ - - - _ _ _ _ _ �- - - - - _ - - - - - - - - - _ - - - - _ _ _ (161,05 TONS) _ _ � — _ � _ __ - - _ _ = i- Og PERMANENT UTILITY EASEMENT IS LIMITS OF General Permit U --_ _=T��n-61��--- --- - ---------------_v -_-- -_—_________ _______________ �r�fli2 = __--- [� — 6 -- - ___-- --_= ---- - ---- - _ -------�30-g9 _---_ —=___ � — _-_-__ _ - - DISTURBANCE. Applies Q =---- --- - -- ---- ----_ --_ - _-_-_- _-----------------_ -_----�_____--_- _---_ -- -NO NORTH CAROLINA SURFACE FRESHWATER - ------ _ - _-_ - - - --__ __--_-_-_ ___=_-___ _-__ - - - = - --_ ____� - � - - -__ _______________- 0 _ - - - - - - - - - - - — 635 _ _ _ _ _ _ _ _ _ _ -- - - - 630--------- -- 10 - - - - - - - - - - - - - - - - - - - - ------ — — — — __—--------------------—— ------ --- -- —_ -- ------ ---- --- — _ — — _ _ _ - — —— — 635 — --- --- --------C'UARDRA1L ---- B-103A _ _ DISTURBED AREA 00_--------` _ _ _ — — � _ _ _ � �—------------------------------------------------------------------ _— — — — _ — s — — — — — — _ --� -- / r _-- ----- -- �, 14.76 AC m (D3 US 421 (NORTHBOUND) 7- — 3 Z --------------- _ _ _---------------------- fTl- - - - — — — — — - -— _RENd_OVE D ---------------------------------------------__— = GIS DISCLAIMER ---- vn� — — — — — — — — --------- —------- ------ -- -- -------------------------- ____ Objects on this ma shown -------- J P —-------- INV=631.76 — — — — — — — — — — — — — — — - - ---- — — — — — — — — — — — — — — — — — — - - — — — — — — — — — — — with a dotted linestyle were — — — — — — — — — — — — - ----- ---- - — — — — — ------------------------------ ----------------- --- _ -------_---- no surveyed, they were 6s2---------------------------- ____ _ r - compiled by photogrammetric ------------------ - --- ------------- ------_ w — D -- methods, availableon e — — — — — — — — — — — — — — — — Geographic Information --------------- --- ----_-------------- -- ----------------- System GIS software used ---- ----� -- — — — —--------- --- ----�-------- _ by the City of Greensboro. 640 \\ Ir 40 0 40 80 O O O O HORIZONTAL SCALE IN FEET O > O 10 0 10 20 co> co 650 T " 650 VERTICAL SCALE IN FEET w� W (n N Q CD 0 U w _J ~ = w U) + U? M 00 �' 0 Cl)N Co Q 2i H U Q "co E 640 LL 640 � J � LU a_ �OQ + a-" + NU 0 w E Q w GRAVEL ROAD z`'' - w o N? U) �"C°' 630 � Q 630 LU CIDw z � w U) _ — � PROFILE OVER — 24' C-900 DR18 FORCE MAIN I EX STING GRADE 620 _ 620 \ / 24" C-90 DR18 PIPE � \ 24" RCP 610 - \ 610 18" RCP o z w a-00 ti 600 Q wP w wti --------- 600 CIDcn + z M Q Q Z ZP w (n 590 LL > 590 J > w u)Q + w + moo NU 10 ~Q co �co �w Q c�Q I zM 580 N fA N U) " INSTALL 24 FORCE MAIN AT A DEPTH w Q •`` REQUIRED TO PROVIDE A MINIMUM CID U)580 ,.` CARO'�� .N••�%,,�� ALL PIPE SHALL BE INSTA LED ON COVER OF 4' BELOW EXISTING GRADE :.�p�.•''ESS /'••. O •••� , A NEGATIVE SLOPE OF 0.1 % OR GREATER LU LU 037518 �. 01 /24/204/2023 570 z ALL PI E SHALL BE INSTALLED ON + ALL PI E SHALL BE INSTALLED ON z 570 :,�'••FNcINEE`��'�,:' •••yE�V J POSITIVE SLOPE OF 0.1 % OR GREATER ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER A POSITI E SLOPE OF 0.1 % OR GREATER J ,i '9 ,, W � U �� K- 360+50 361+00 361+50 362+00 362+50 363+00 363+50 364+00 364+50 365+00 365+50 366+00 366+50 367+00 367+50 368+00 368+50 369+00 369+50 HDREngineering, Inc. REVISIONS TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P- 05805C CITY OF GR EEN SB OR Oof 04C-12 the Carolinas NCBELSLicenseNo.F-0116 ROADWAY DESIGNED 11 2022 BY MAS WATER RESOURCES D E P A R TM E N Cha ott ,N� azozzo7500 SEWER 2022-013C CONST. SURVEY BY GRMS Phase IV Sewer Force Main Extension SHEET NO. 704.338.6700 24" FORCE MAIN US HIGHWAY 421 WATER CHECKED BY PLAN AND PROFILE 16 OF 43 100% SUBMITTAL SIDEWALK SCALE: AS NOTED STA 360+00 TO STA 370+00 GENERAL NOTES: O O O 650 co Q 630 620 610 M M 570 LU J U REFER TO SHEET 04E-07.4t FOR EROSION CONTROL 0093E (P-05805C-06) NORTH CAROLINA RAILROAD HOLDINGS I, LLC FEMA 1 % ANNUAL 5990 STARMOUNT RD l ° FLOOD HAZARD AREA RC REID 75464 o V D9 2489, P& 887, PARCEL 32 PROP. FORCE MAIN-- OAIR RELEASE VALVE (COG STD. 211) W/ 6' M H Do ' _ STA 377+87 N 773955 = Q r E 1812974 oN t/t j / 605-'� O -604- /IN 605 w/ I/ / /% /' ' �� Ox FEMA1%ANNUAL / o`V/ // / /t /' ���// �t 606-- \\ \ \ \ \ FLOOD HAZARD AREA <o / t/� �% / // /' -607 - - _ j O -� � �} �� \\� \ �\ TRANSITION TO10'OFFTOP OFLAKE BANK // / oo� ` � -' 609, v 609. O+ \ \ \ \ �� \ \ \ � \ \ \ \ \� 4 •/ / // } / � GCS/ / / / j / / / � ��610 DODSONS LAKE Q \ } \ \ \ 1 WE 601.2 '� PROP. 24" GATE VALVE I �. PROP. FORCE MAIN \ \ \\ \\ ,n \ I i / \ \\ \ o P-A-183-1 �/_ h _" / / STA 377+74 / / / _ - - - (n AIR RELEASE VALVE \ \ I _.__� � / / / I — — — \ (COG STD. 211) \\ \ \� \ \ \� \\ ` \ I \ \1 EDGE OF PAVEMENT i% c��� / / N 773958 O / /_ i J / — 1 612 _ \ W/ 6' MH \ \ \I 6 1 I : Q- ib�-0� TOP OF BANK �� _' _ -JaE o�? ��-t/ / / / / / / ^ + E 1812962 / o \ STA 370+39 \ \ \ \ \ \ I I I �I , ' A A i , A • i •0 �- 0 , b b •0 s '//_613'' " ' i '' a a , ' ,� ' a ',,A i ',i ii a �' / OE E_ N 774625 E J`�n 'I I 1�5 OMP y 5 M NE 1812663 1 E f �Q T E'�i �i 'i i 5 i�4� �i iiln`/.i�InA 602.`f54 �i ii �i , i+ , / / 60 = / ' / / / // / / / / ' /v 6A4— ' ' '� Ian V� Ou't �01 .5� �i� — E�� E E E 5 -- M \ FMI I77 I T3�70 �__-,� so4rso4 --�� ��- I _ FM 373+0 B1+ H—� T Tom- - T 3,74+00 / EX. R/W LINE -,oj ,M I o o �' G =��—---�Ir=rr—x— —x ,- - _ _ _ FM FM F _CM F'�= - - _ - -60 �. _05 ro ^� q� 6, 6, .6 ! ,/-JxLv. In 602.19 -- _- �6 foo 00 00 09 'o, 0. J �' o '1 PROP. 24 GATE VALVE / / / ( rn a \ / Inv. Q1i t 601.65 r > / SIGN Y // STA 370+26 \ �- \ 7 ' o / _ LUI ( /N 774636 O / / / / (� �- - � RETE FLUME _sew _ - - - - — — _ - _ , = — — — 9 \ / PROPTA . 24" RJ FITTING / / 04 _.I ` \ _--T-- _-� / /�i �� / E1812951 /�� _ r _ W0136S - - - 1 PROP. 24" C-900 DR18 FORCE MAIN _ - - - I - - \ \\ - - - - OPEN CUT AND REPAIR _ �/ ' U _-_-_ _ - _ — 610-- — - _ GRAVEL DRIVE FULL WIDTHzz - STA 372+50 TO STA 374+00 - _ _ _ _ _ (63.00 TONS) _ — ----- _— 2GI—FG--____------- -- _----=-__--------_ __--_ (xsection -US 421 (NORTHBOUND) �( \ of 253 — -- —---------) — — — - _ — --- 3 — _ _ _ _ — _---------- _---------- _ — — --- --------_ \ ------ — J \ \\ 3 2GI—FG \ ------------------�� --- — — 635 — - — — — — —--_____ _ _ _ �_ T==---- TRENCHLESS INS �TALLAI 94 I -- --- _ -- ----------- --- _ — — — — _ -`(� 18" ELDED�ST ESL --------- - -------------- -------I1=6`z_334 -FLU �cMO LC DID\ _ _-_ --- SIG _ , /SIG _ N / -_--- /Al c�/ \ \ W J Q W N rn M Lr) LJL.I U = 0 M M 0 Q 2i QC) cory 9W LU Q O (D co _ Q N cn ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR REATER 370+50 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 ALL PIPES ALL BE INSTALLED ON A NEGATIVE SL PE OF 0.1 % OR GREATER 371+00 371+50 372+00 372+50 15" CMP 15" CMP I 373+00 373+50 PRO ILE OVER 24" C 900 DR18 FORCE MAIN EXIS ING GRADE 24"IC-900 DR18 PIPE INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW EXISTING GRADE ALL PIPE SHALL BE INSTALLED ON A 374+00 374+50 REVISIONS 375+00 REVISED PER NCDEQ COMMENTS 100% SUBMITTAL ITIVE SLOPEI OF 0.1 % OR GREATER 375+50 TYPE ROADWAY SEWER WATER SIDEWALK 376+00 CONTRACT 2022-013C W J Q W N M M 0� O Q 2 Q� �Of W + QM Q C7 Z N CO ILL co �+ o LO M Q N co 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. KEY NOTES: ORIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. O2 PROVIDE 2'x2' CONCRETE PAD AROUND VALVE BOX. OFUTURE NCDOT ROADWAY PROJECT WORK. NOT IN CONTRACT. O4 FLOOD PLAIN INFORMATION PER FIRM PANEL 8717, MAP NUMBER 3710871700J, EFFECTIVE DATE 1/2/2008. FLOOD ELEVATION EAST SIDE OF US HIGHWAY 421: 608 FT. NO ADDITIONAL 1 % FLOOD HAZARD AREA IDENTIFIED IN THIS LOCATION. O5 PERMANENT UTILITY EASEMENT IS LIMITS OF DISTURBANCE. O6 TEMPORARY CONSTRUCTION EASEMENT LINE IS LIMITS OF DISTURBANCE. 0DO NOT DISTURB FENCELINE ALONG CONTROLLED ACCESS/RIGHT-OF-WAY. O8 NORTH CAROLINA SURFACE FRESHWATER CLASSIFICATION FOR DOTSON'S LAKE P-A-183-1 AT THIS LOCATION: WS-III. DOTSON'S LAKE IS A PART OF THE CAPE FEAR RIVER BASIN. OPROTECT POWER POLE. CONTRACT SHEET 17 of 43 SENSITIVE INFORMATIO Not to be copied or distributed without the express written permission of the City of Greensboro. North Carolinas 8� , www.nc811.org City of Gree oro a round Locates I o I e uests COG Water eso s e 73-2033 GDOT Tr Si a _ - - 73-2606 COG/Guilf rd Co. Telecom - 73-2084 COG Water upply _ - - - - - ,73-5855 Tanks/Tre tment Plants GDOT Storm ter _ - - - -373-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 p HORIZONTAL SCALE IN FEET + 10 0 10 20 O 00 co 650 VERTICAL SCALE IN FEET a U) 640 630 620 o z 610 � I 600 590 W a - a+ M o580 ,,,,,� CAR0,,,,,. p� ESS %0 E� 037518 z 570 ': 01 /24/2023 ALL PIPE SHALL BE INSTALLED ON .,�gTNGINE•�'�,�` A NEGATIVE SLOPE OF 0.1 /o OR GREATER 376+50 377+00 377+50 378+00 378+50 NTRACTOR AS —BUILT 1AUTH. DATE IWATER AND SEWER PERMITS 379+00 379+50 JOB NO. P- 05805C DESIGNED 11 2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED ----i K- CITY OF GREENSBORO WATER RESOURCES DEPARTMEN GRMS Phase IV Sewer Force Main Extension 24" FORCE MAIN US HIGHWAY 421 AT STARMOUNT RD PLAN AND PROFILE STA 370+00 TO STA 380+00 04C-13 SHEET NO. 17OF43 PROP. 24" 45° RJ FITTING \ \\\s9s \ ^� \ REFER TO SHEET 04E-07 PROP. 24" RJ 22.5° FITTING STA 387+17 \ \ \ L- FOR EROSION CONTROL STA 386+25 N 774005 \ \s \ g N 773926 E 1813815 E 1813754 \ 0093E (P-05805C-06) \ S FEMA 1% ANNUAL NORTH CAROLINA RAILROAD \ \ s O j FLOOD HAZARD AREA HOLDINGS I, LLC +O ( 1 ( 5990 5TARMOUNT RD 20' X 10' C) S 1 \ O RC REID75464 LAUNCHING PIT '171)co ) I I DB 2489, PG 887, PARCEL 32 66 LF OF 36" STEEL CASING PIPE, \\ \ S8 0.375" WALL THICKNESS I s 61 \ \ / i \ \ \ RECEIVING PIT \� 1 �pg'`o \ 2 \ \\ 1 PRO 24� c-0 Q11R`I8 FORCE MAIN// \ \ \ \ \ \\ \ PROP. 24" 45° RJ FITTING >i/ \ / \ \ \ FM \ S9A `593, �� cr/ STA 384+52 7 I / \ \ \ \ \ \ a. \ pow �o N 773828 / / PERENNIAL oD \ FM \ \ \ �� E 1813626 /� STREAM / °� \� LO \ \ 1 FM ��\ \ s90 \\ �\ \� \\ _ S-Q Ld / , F \ C QAF- s _ _;� // 10 \� 2 1 + y, FOCI FOCI— FOC FOC FOCI FO FOC FOCI- FOCI FpC� � C ` �OD \ \ _ _ �\ TOP OF E WALL 7.11' \ \ \ FOC-� FOC \ Foc LOD \ _ I APPROX NVM FOCI FOC. FOCI ="12 _ _ 1 \ ETLA SALD I / / OPEN CUT 1 11 OF 36" STEEL CASING PIPE, PROP. 24" 22.5° RJ FITTING 0.375" WALL THICKNESS STA 389+61 E 1814030 I 1 I f \ \ x I \ \ \ — ` PROP. 24" 45' RJ FITTING STA 389+81 N 773875 E1814043 PROP. 24" 45' RJ FITTING — F `9j4 — — — — 03- X STA 386+97 \ 600 N773999—_ \�i— — -----\ E 1813796 \ — — O 600 595IMAI2THA BLALOCK HUMBLE, LIFE ESTATE \ 4958 STARMOUNTRD 8 �\ RC REID 75474 I II I \\ 5 LIN\ *-rI�BOOK 83E,PA6E25 3 MATCHE_ STA 390+00 w L O J \ - \ \\ II c� I � � � `� \ ZJ FOCI FOC \ x \ \ x \ 59 \ F0= FOC�FOCI FOC— °COCFocE R — _ / P I \ ' � T — T _ r j y�roc W T 585 — 24" </ \IR P� �/ --- _ --OI CS ��� > � 3 -- _--�— �\ --`—_-- / III --— _ \ \\�\���--\--�_= 00 7"7— 59_0 — — � /� `_ 585 — -- _ � Jkl 01 OF ALL 13' AP 5 .2' \\ \\� \��\ cr CS � x a O O + O 00 630 cY) H I U) 620 - 610 I 600 590 I 580 I 570 I 560 550 W J U 380+50 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 O 60 o z' _ 24" C-900 DR18 PIPE C $ W W W W �WWWWWW'W 0 / WWWW.W.W.WyWyWy PROFILE OVER 24" C-900 DR18 FORCE MAIN EXISTING GRADE w 0- a- 0) co Z 00 INSTALL 24" FORCE MAIN AT A DEPTH w m U) REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW PROP FINISH GRADE ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER I 0 / CLAs P T� TION SEE DEB IP RA ON SHEET 11 3 D �W. 13 i xl 5 II I 3 W O 5 �'I W W wl x, 0 1 3 I I 11! �I I 1� I I 1 I III \ f I L l== 30 0EST. 22 VI SEESy I ON SHEE- GRAVEL DRIVEWAY FUTURE RELOCATED STREAM CHANNEL (NI ) / o Z 127 LF,OF 36" STEEL CASING PIPE, n -A75" WALL THICKNESS GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. �J LIMITS OF DISTURBANCE. ORIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. OFUTURE NCDOT ROADWAY PROJECT WORK. NOT IN CONTRACT. O4 FLOOD PLAIN INFORMATION PER FIRM PANEL 8717, MAP NUMBER 3710871700J, EFFECTIVE DATE 1/2/2008. FLOOD ELEVATION EAST SIDE OF US HIGHWAY 421: 608 FT. NO ADDITIONAL 1 % FLOOD HAZARD AREA IDENTIFIED IN THIS LOCATION. OPERMANENT UTILITY EASEMENT IS LIMITS OF DISTURBANCE. OFUTURE NCDOT RIGHT-OF-WAY. ONORTH CAROLINA SURFACE FRESHWATER CLASSIFICATION FOR STREAM S-Q AT THIS LOCATION: WS-III. DODSON'S LAKE AND ALL ASSOCIATED TRIBUTARIES ARE A PART OF THE CAPE FEAR RIVER BASIN. OFUTURE ROAD -Y4-, NCDOT ROADWAY PROJECT HE-0004, TWA2. OINSTALL STEEL CASING PIPE USING TRENCHLESS CONSTRUCTION METHODS IN ACCORDANCE WITH CONTRACT SPECIFICATIONS. ALL PIPE WITHIN THE CASING PIPE SHALL BE RESTRAINED JOINT. 10 DO NOT DISTURB STREAM BANKS OR STREAM BED. 11 INSTALL STEEL CASING PIPE BY OPEN CUT. 12 FUTURE OVERHEAD POWER (NOT IN CONTRACT). 13 FUTURE RELOCATED RANDOLPH TELEPHONE (NOT IN CONTRACT). 14 FUTURE TEMPORARY CONSTRUCTION EASEMENT FOR ROADWAY WORK. CONTRACT SHEET 18 of 43 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. North 8� j Carolina www.nc811.oI City of', Gree or a rounc Locai:es I or I e uests COG Water eso s e 73-2033 GDOT Traffi Si a _ _ _ 73-2606 COG/Guilf rd Co. Telecom— 73-2084 COG Water upply _ — _ — — _ 73-5855 Tanks/Tre tment Plants i GDOT Storm ter _ — — — �373-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. Y U 40 0 40 80 Q m HORIZONTAL SCALE IN FEET ti 10 0 10 20 O 630 VERTICAL SCALE IN FEET O O M Q U) 620 610 I IT 600 590 ---- -- (D 66 LF OF Z c� 36" STEEL C ING PIPE, z 570 0.375" WALL T ICKNESS Lo a) C)) co L0 � Z U 0 ~ z — � C lr­ U) N (n 560 U- lm-- o Id) LL r-- LL ti C17 N CY) C'4 (fl co CO L0 M Ln M N U) LAM N U) N (n - LU z 550 ALL PIPE SHALL AL BE INS LED ON A POSITIVE SLOPE OF 0.1% OR GREATER = I I I 381+50 382+00 382+50 383+00 383+50 384+00 384+50 385+00 REVISIONS TYPE ROADWAY 1 2 3 4 SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK 385+50 386+00 386+50 387+00 387+50 388+00 388+50 389+00 389+50 390+00 CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805C DESIGNED 8 2023 BY MAS 2022-013C CONST. SURVEY BY CHECKED BY SCALE: AS NOTED K- CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension 24" FORCE MAIN STARMOUNT ROAD PLAN AND PROFILE STA 380+00 TO STA 390+00 CARo JLAL 037518 �.12/20/2023 T �NE1w,.Tlp 04C-14 SHEET NO. 18OF43 1 GENERAL NOTES: CONTRACT SHEET 1 REFER TO SHEET 04E-08 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY 19 OF 43 1 FOR EROSION CONTROL SPATIAL DATA CONSULTANTS, INC. AND BRADY j 1 SURVEYING COMPANY, P.A. DURING THE WINTER OF 1 2015. / 1 2. DEFLECT PIPES AS NECESSARY PER SENSITIVE I N FOR M ATI 0 MARTHA BLALOCK HUMBLE, / 1 MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN Not to be copied Or 1 LIFE ESTATE ALIGNMENTS. distributed without the 1 5958STARMOUNTRD THOMAS FRANKLIN WHITE5ELL k0� RC REID 75474 ANDWIFEKATHY CHURCH WHITE5ELL KEYNOTES: express written n 3g0 / 5902 STARMOUNT RD WILL BOOK 83E, PAGE 25 1 RC REI075476 permission of the City / y yy y0yy O DEED BOOK 1939, PA&E 1917 1 LIMITS OF DISTURBANCE. PROP. 24" 45' RJ FITTING y INTERMITTENT 0 of Greensboro. STA 391+22 / 1 y , y STREA PROVIDE 2'x2' CONCRETE PAD AROUND VALVE BOX. N 773733 1 yy yy yy yy y S-E O ( 12 E 1814038 / o - y PROP. 24" 45' RJ FITTING O FUTURE NCDOT ROADWAY PROJECT WORK. NOT IN � \ I / 1 y yWETk/�J'l[?'y0 STA 396+41 CONTRACT. MP�a U I 1 ° / /Y -411/ J 1 I I I I I I I I W-� y N 773523 1 �� �� _ - // i i// i/ / iik I PROP. 24 22.5 RJ FITTING \ / )/ / / I I1 I I I I / yam,\" yyy' E 1814512 / / / / / // / / / / / / / / / STA 391+42// O4 FLOOD PLAIN INFORMATION PER FIRM PANEL 8717, \ ✓/// yyy N 773719 11 \ \ ��, J / /lam �rl' �- - S15 PROP. 24" GATE VALVE l I l / I I I / / I I / / / y y" ' y \ .,Ot I PROP. 24" 45' RJ FITTING /� / // j/ / / // MAP NUMBER 3710871700J, EFFECTIVE DATE ; $ ( E 1814053\ \ / /� \ STA 393+96 / / / I 1 I / I 1 / / / /� y y ' yy / + / �/ // / / / // / / / 1/2/2008. FLOOD ELEVATION EAST SIDE OF US /� \ N 773620 O / o / / %/ / I I J I / / OL 1 I STA 396 55 / / / / / / / / / / / / / / HIGHWAY 421: 608. NO ADDITIONAL 1 % FLOOD / . yb .\ N773510 / / / / / / / / / l \ I \ \ OPEN CUT E 1814287 / / co I / / / / // / y 0 \ \ / / /� HAZARD AREA IDENTIFIED IN THIS LOCATION. Cn / I I I \ \ \ B �/� AND REPAIR / o / / co o / y E 1814517 / yy C"' I I I 0 I p 0� \ !POD 6, \ \ \ �2 _ /� / I l l l l GRAVEL 01, y y"y 10, X 10' QP I I O5 NO NORTH CAROLINA SURFACE FRESHWATER DRIVE \ 6 / / / y RECEIVING PIT \� \ \ \ \-�rOH/P I I CLASSIFICATION EXISTS FOR STREAM S-E. CHy of Gree oro a round 6 \ \ \S% - l / / / / / / I / L y \ OH/P OH� OH/P -� °HIOH/P I OH/1' 1 I OH/P( O 3.52 TON / °H/ OH/P OH/P )1 , Loca�®s 1 o I e nests \ o I—� Z / / y I I / \ \ 613 OH/P{ �- /P�-°/w/P ° /P D P H/P I J�\\ \ \ I O O RIGHT-OF-WAY LINE IS LIMITS OF DISTURBANCE. \ \ \ \ �6, P I LL, I I OH P OH/P off/P °if/P-� / / / / / �� + COG Water eso s e 73-2033 OH/P / / 1 I (/ Y /j 1I o I, / 0. \ X-1�13915. \ 1 \\ \ \ \\ 09 PQP / / O 6 \ GDOT Traffi Si a _—_ 73-2606 / I �" -M -� o 00 /off/ co / co I �� �O \ \":\ S� \�'\ 7 EDGE OF PAVEMENT IS LIMITS OF DISTURBANCE. COG/Guilf rd Co. Telecom _ 73-2084 Y=77376 \ \\ \ \r _ _� _ _ \ \ \ \ / CD / / / / /co o w o ,o / o / \ \ O \ \ `— —a \ ` \ _ _ / / / / / 'Co �O < \ \ \ \ \ \ \ CO Water u - — _ — _ — 73-5855 Z= 588.329 N � -� �` �\\ \ _ \ +Q�- `I - � - - - _ _ _ / _/ _ / / / / / � cn rn �I Q I / / / / � / / \ \ \ \ \ pP Y \ \ \ \ \ \\\ +QQ o, T— �C / Q 8 Tanks/Tre tment Plants 10 \�\ \\ _-�_ __ \_ -/ (10/ / /- �39 Obr— - i - - - - - - _ _ _ _/ l I \ \ \ �I� O PROPERTY LINE IS LIMITS OF DISTURBANCE. — FM- _ — / / — — I _ \ \ _ GDOT Storm ter _373-2569 \ FM VA / - \ _ - —_ _- -_ _ _ _ - _ __ - _ _ __ - -__ - RELOCATED RANDOLPH TELEPHONE. NOT C OC FOf` FOG 0 I FOCI FOC FOC j F6C- FOC Fes. ,� \\� �- - - \ - - �_ \ 0 � � I I \ > > FOC�FO — — — F F°c�F°c \ \_ // 11 8 I - - - - _ FUTURE T-T�T_L T- 1 i-7 -idT 7 T F°Cr-F0 �9" / �FOC�FOC—_Foc-= �— �� / L/ NV�5 2�.26� —=28 �� i � IN CONTRACT. r F =FOB-� F9C= FOC FOCI OC FOC FOE- FOC-- FOC FO 5 O-7 > FOy O ~ �FOLI -=-__S _ 7 - T - T i - T - O� FOC- FCC`-- FOC- = FOC FOC FOC-HOC HOC C_= f � G� �FOC- F9C' FDC� FOCI FOC FOC-7 71�717L'97�-&,o 13 3 ( �0 PR - T—�� = iT- -ice _ - T7_'i - �TT� iT = 7=t777- L7-Ti i—iTi r =r�7y�-=Ti� �`i�-��'-10 FUTURE DUKE ENERGY POWER POLE AND GUYNPDES s� SO O S9 rn -I _ - T �jIT- \� 37 LF OF 36 STEE / 20 PR / / / 9 7 �� PROP. 24" C-900 DR18 FORCE MAIN CC- I �� 15 / / - _ — �— _ ooSTARM0JNT RD (SR 2407) CASING PIPE, ( 7 ( WIRES. General Permit -- ---- r ----�---------------- _--------- _--\---- -- L--=0.375 WALL THICKNESS------- -� -- - ��-� - \ 0 _ _ - 11 TEMPORARY CONSTRUCTION EASEMENT FOR PROP. FORCE MAIN _---_-_- _-_--- - a---_ _MB �� ���� �i999Q Applies \ \ \ ROADWAY IMPROVEMENTS. NCDOT PROJECT �- ----_ —__--- - ----= AIR RELEASE VALVE _ _ � \� IM �!� REFERENCE HE0004, PROJECT NO. 499797.1.1. 3 \ \ \ \ 9 / - - - _ _ - . (COG STD. 211) \ )II \\_J FM \ \ \ \ \ \ 20' X 10' sgs l _ _ _ - - / / - r - 12 NCDOT REVISED RIGHT-OF-WAY LIMIT. NCDOT \ FEMA 1% ANNUAL \ 9� ,s9� ,599 �00 �O \00 so \�, \ STA 394+08 LAUNCHING PIT _ _ _ - -�-1- -�' �- \ \ \ / I 1 E / PROJECT REFERENCE HE0004, PROJECT NO. DISTURBED AREA = \ \ \ FLOOD HAZARD AREA 4 \ ,` `' `�� OR \ N 773615 - - - -� \ I 6 \ \ 1 cV Jw I 499797.1.1. 14.76 . A \ \ �0 \ \ \ \ — 605 co — —f— 7— ��\ \ I \ \ 1 Qi ro co cn `t b \ -r E 1814298 / \\ \ o 0 00 C4 14 13 FUTURE DRAINAGE DITCH. NOT IN CONTRACT. E --/77_/ / / / / /\ �\\ t I I I i 600 v' / I / 1 I �Z \ \ / / / / �� `\ i /) �\ I I I I , \ II I o N ; i I I II \ \ I 1 = 14 TEMPORARY CONSTRUCTION EASEMENT IS LIMITS I \ I � I I \ I I OF DISTURBANCE. I I \ I / I I i 0002 (P-05805F-O6) U DUANEF. WALL 1— GI S DISCLAIMER AND WIFE Q ,3I ) I \ - / / / / / / \ / / \ \ I 1 ( 15 INSTALL STEEL CASING PIPE USING TRENCHLESS 1 6' 1 \ I \ \ \ \ \ - — / / I I I CAROL S. WALL Objects on this map shown G P w I I I ` \ \ \ \\ \ 0095E P-0 - I / / / / / / / \ II�/� / / I \ / // I I I I RCREID 7547 METHODS IN ACCORDANCE WITH CONTRACT with a dotted linestyle were V1, h / / / \ / / I PROP. 24 45 RJ FITTING SPECIFICATIONS. ALL PIPE WITHIN THE CASING PIPE I r��j0 -'r "�1(�E I 1 I I \ \ ( 5805c 06) / / / / / / / \ , / STA 397+16 / I I I I DB 2242, PG 07 not surveyed, they were %l MONARDLLC / / / / �/ l / i / / I / / / 1 SHALL BE RESTRAINED JOINT PIPE. E .� Q 8 — — / , I N 773453 1 compiled by photogrammetric CC7� RCREID 82926 / / / / I�((�rt I\ i I I / / i methods, available on the S�E DG� DEED PAGE68 BOOK 2438, PA &E 9 E 1814508 Geographic Information QN SN ° 1 System (GIS) software used I PROP. 24 45 RJ FITTING 1 by the City of Greensboro. / STA 397+01 I N 773467 \ E 1814501 1 O I O O 0) 650 co Q H 07 I 640 630 620 I 610 570 w J U H o z 75 GRAVEL DRIVEWAY " C-900 DR18 PIPE z ­3 J I__OfQ L U rn M w Q N - U) z I z z LL LL N � J o + o + Q + ° rn L0 - U co � M N M M N Q CV Q Q - w N U) N U) _ _ N CO ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER 390+50 391+00 391+50 392+00 392+50 393+00 393+50 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 w J Q LLJ J) N ao Q o � LLJ 0 _ + N W U rn O O Q QUA c�Fy 24" C-900 DR18 PIPE 24" GATE VAL STA 393+96 (D PROFILE OVER z 24" C-900 DR18 FORCE MAIN EXISTING GRADE J ti � Q + N U rn � M Q - W N > (n PIPE SHAL BE INSTALL D ON A NEGATIVE SLOPE OF 0.1 % OR GREATER 394+00 394+50 REVISIONS REVISED PER NCDEQ COMMENTS 100% SUBMITTAL M CO Q STARMOUNT RD 37 LF OF 36" STEEL CASING PIPE, 0.375" WALL (D THICKNESS z LL o + f` ° 't o') M Q w a- 6) �I__ rn M C) Q z F-- Lu I cn INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW EXISTING GRADE I o Z N Cn N (n ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER � I 395+00 395+50 396+00 396+50 397+00 397+50 398+00 398+50 399+00 399+50 TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805C ROADWAY DESIGNED 11 2022 BY MAS SEWER 2022-013C CONST. SURVEY BY WATER CHECKED BY SIDEWALK SCALE: AS NOTED 40 0 40 80 p HORIZONTAL SCALE IN FEET O 10 0 10 20 O 650 VERTICAL SCALE IN FEET Q H 07 I 640 630 I 620 610 M. 590 580 C A R p�,. I ���•� �� S S % 0% -P �v--*SS SEA �= 037518 = ': 01 /24/2023 LU 570 U K- CITY OF GREENSBORO 04C-15 WATER RESOURCES DEPARTMEN GRMS Phase IV Sewer Force Main Extension SHEET NO. 24" FORCE MAIN STARMOUNT ROAD PLAN AND PROFILE 19 OF 43 STA 390+00 TO STA 400+00 I I \I 1 I I I \ \ � I I � \ / I \ LYNDA C. WILLIAMS I I \ \ STARMOUNT RD O \ I \ \ RC REID 75473 \ O 1 DEED BOOK 2649, PAGE \ \ \ \ \ \\ \\ 1174 O0 \ N W \ON ° C:) \ %10 0 637 116'c,, v,\ co �T FOC T FOC / __T �F� _ \ 1 / / I I / II' Q \ \ \ I II �> T =0C°C I FOCI T - - CD CD _T—_CD FOCI F=C� FOC�� —"/P �= =\— - - - - _ _ FM H+M�- — 1— _ \ / _ - �°--— — — — — — — -! - --_- -�- - �- _ _Q R T� — � ��= � �- / '- OCL � � _iwoo-------ego ----4 ±OQ- �� FM FM F LLJ E I 11 \ oy E a /�P7�`E EETE _ o-- -- x -- - -- �- E E E °" LJJz1 I \ OPEN CUT AND \ \ W �X REPAIR GRAVEL \ \ PROP. 24" GATE VALVE U \ / DRIVE (4.54 TON) \ sr,� o STA 404+52 O F- \ \ \ \ N 773213 2 E 1815202 OPEN CUT AND \ \ \ \ 000REPAIR GRAVEL 2 AND6 (P-05805F-o I \ \ \ DRIVE (6.83 TON) DUA F. WALL � � I � � \ WIFE � � / I CAROL S. WALL I RC REID 75472 DB 2242, PG 407 I I I I I O O O O 650 H I U) 640 630 620 610 M 590 580 570 W Z U GRAVEL DRIVEWAY I/ I REFER TO SHEET 04E-08 / IFOR EROSION CONTROL / I / I / I JIMMY J. WHITERKER / L AND WIFE SJA GLOBANELMA J. WHITERKER ADVISORS, INCI 5820 STARMOUNT RD / 5840 STARMOUNT RD I RC REID 75486 / RC REID 75485 DEED BOOK 1664, PAGE / DEED BOOK 2786, PAGE I 1496 _ 2336 \ \ \ I I I \ PLAT BOOK 59, PAGE 37 \ 1 W PLAT BOOK 59, PA6E 37 ` 1 \ I ) \ I \ \ \ \ \ 1 111 " oT PROP. FORCE MAIN \ \\ V COMBINATION o so_607_ AIR VALVE 7 -O W.6'MH �,\� O \ III \ I �, N STA404+64 w w IW IN I� I �N\N ti tio' N 6+r, `''WNr' N773210 w ►? o Ilrn�o I rn\3 Co v rn E1815215 _) / 1 \//j \ _(n PROP. 24" C-900 DR18 FORCE MAIN —_ — \ — \— �/— 1 = , RMOU_N_ 4-1 + �SR 2407�_ ---------- ---�---- - T RD_ 408� _-�_40�-o_-/ - �� --- ��--406+00------- -bt8�- FM FMI FM FM�� FM FM E OH/P OH/P OH/P OH OH/P OH P OH/P OH/P OH/P -------� H/P OH/P OH/P OH/P OH/ OH/P OH/P OH/P / OH/P OH/P OH/P \ \ \ \ \ \\\ \ \ \ \ 6"j \ PP \ \ \ I w \ \ \ \ \ \ \ \ a ��<s - �� v r. ens a ate^ �,^' W \ N Z_ 1 � , � s N o \6'c,+ \ 3 \631 \s`�O s�9� s?8 2, 26\ �s \ \ \ 3 \ \) J I OPEN CUT AND = ?\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \. \ \ I/ / / ( / REPAIR GRAVEL DRIVE (3.78 TON) \\ \\ \\ 630 0095E (P-05805C-06) 0005 (P-05805E-07) 0001 (P-05805F-06) MONARD LLC RC REID 82926 D8 2438, P61149 PB 138, P6 68 IL DRIVEWAY PROFILE OVER 24" C-900 DR18 FORCE MAIN EXISTING GRADE GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. KEY NOTES: 0 EDGE OF PAVEMENT IS LIMITS OF DISTURBANCE. OPROVIDE 2'x2' CONCRETE PAD AROUND VALVE. OTEMPORARY CONSTRUCTION EASEMENT LINE IS LIMITS OF DISTURBANCE. CONTRACT SHEET 20 OF 43 SENSITIVE INFORMATIO Not to be copied or distributed without the express written permission of the City of Greensboro. 8� _� / www.nC811.oru Clay COG Water eso s GDOT Traffi Si a 73-2606 COG/Gui1f Je73-2033 rd Co. Te73-2084 COG Wat upply - —73-5855 Tanks �e tment PlaGDOT St rni ter _ —73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. 40 0 40 80 OO HORIZONTAL SCALE IN FEET + 10 0 10 20 O 650 VERTICAL SCALE IN FEET �U) 640 _ 630 _ J � 620 oz_ 24" C-900 DR18 PIPE o z Jw W Q N a_ _ + Q O C+p — O o Z Q � � = zQ w w Cn 600 m 590 INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW EXISTING GRADE 580 .,SS CAR I 037518 LU 570 01 /24/2023 r ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR 1ATER ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER T_ \N`i'ip:�`' I112 K- 400+50 401+00 401+50 402+00 402+50 403+00 403+50 404+00 404+50 405+00 405+50 406+00 406+50 407+00 407+50 408+00 408+50 409+00 409+50 HDR Engineering, Inc. REVISIONS TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805C CITY OF GREENSBOROof the Carolinas 04C-16 NCBELSLicense No. F-0116 ROADWAY DESIGNED 11 2022 BY MAS WATER RESOURCES D E P A R TM E N 440S.te,NC 8202-ite 075 SEWER 2022-013C CONST. SURVEY BY GRMS Phase IV Sewer Force Main Extension SHEET NO. Charlotte, NC 28202-2075 704.338.6700 24" FORCE MAIN STARMOUNT ROAD BY SIDEWALK SCALE: AS NOTED PLAN AND PROFILE 20 OF 43 100% SUBMITTAL STA 400+00 TO STA 410+00 11 \ �589- III i I PROP. 24" 22.5° RJ FITTING l \ i \ GENERAL NOTES: I I AP RQ C. NV.- \ \ \ BORE & JA 5 61 LF OF ^ /II \ III / I _ _ _ _ _ _ I \ CONTRACT SHEET PRO- V. 582. \ STA 415+38 \ 36" STEEL CASING PIPE, // �_ 1 I/// / I I E 1816182 71830 _ _ =_-� _ j / // \ CK \ 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY 21 of 43 \ i� X-18161zJ 6fl 8 6 8 SPATIAL DATA CONSULTANTS, INC. AND BRADY \ LUTHER GENECOBLE \ \ I /0.375" WALL THICKNES / - - - - - - / i / SURVEYING COMPANY, P.A. DURING THE WINTER OF AND WIFE�F=7�2$2 7---=_----- ----- 1 /__ ') 1+' d Z=591.534 7 -�`--� - ( \ 2015. \ EILEEN MARTIN COBLE / / ( ` \ 1 �cS`� , ' 1 _ — — — — — _ _ =/ _ / I t ( 1 \ PCRD I ` 1 \20- 10'LA NCHINGPIT /'� -P 1� �\ _ _ - PROP. 24"22.5°RJFITTING - ��\-� \\ \ `\ _- -\—\ SENSITIVE INFORMATION \ E D � I I \ � \ _ _ _ _ - STA 415+67 - _ - `� _�-- � � \ \ \ � \ \r _ 2. DEFLECT PIPES AS NECESSARY PER \ DEED BOOk 1378, PAGr 31 I \ , I �T = - - _ - _ _ _ �� - N 772801 MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN Not t0 be copied Or PLATBOOK\130, AGE138 / 1 - 1 \ -� _ �� ALIGNMENTS. C�IStrlbUteC� without the \ / PROP. 24" 22.5° RJ FITTING �� 15+� x -x X E 1816186 ` _ -> > \ \ STA414+20 ��i--- \ o I I .' -\ T\ ° KEY NOTES: express written co o I I N 772931 / , \ PROP. 24" 45 RJ FITTING - - _ I M E 1816122 / �j \ \ STA415+80 �� \\ \ \ I / ( / /— -- _ permission of the City \ I to X !' ���� / \ LIMITS OF DISTURBANCE. REFER TO SHEET 04E-09 // \I I / I of I �/ / r ' �// // jx�'C `f (: \ \\\ h \( \ - \ N 772788 �\ \\ �1 1\ \ 1 \I 1\ \ \ 1 \ \ \ \ \ / of Greensboro. FOR EROSION CONTROL I I I / //l.y ,� 1 \� \ ; )/ i U % ` E 1816183 �SgO \ \ 1 \ \ \ \ \ \ \ \ 2O FLOOD PLAIN INFORMATION PER FIRM PANEL 8717, \ \ MAP NUMBER 3710871700J, EFFECTIVE DATE 7 2) CP �� I l�l \ \ 1 \ 1 11\\ \ \ \ � \ \ \ � 1/2/2008. FLOOD ELEVATION SOUTH SIDE OF 8. X 6' I� IGH\ / \\ �M'• �/ `.�\ \ _ \ \ U \ 1 1\ 1 1 \ \ \ \\ \\ - STARMOUNT ROAD: 588. NO ADDITIONAL 1% FLOOD �SA�PvROX. V. �82.3' �' `� `. t�` PROP. 24" 22.5° RJ FITTING 1 \ \ \ PPRO X1. 582.6' \ / \ \�\ / I \ STA 416+18 1 1 1 \ 1 \ 1 1 \ \ \ \ \ HAZARD AREA IDENTIFIED IN THIS LOCATION. , All RECEIVING PIT S \ N 772768 2O 1 I 1 \ \ \ \ \ 3 NO NORTH CAROLINA SURFACE FRESHWATER E 1816150 \ 1 \ \ \ \ \ FEMA 1 /o ANNUAL CLASSIFICATION EXISTS FOR STREAM S-A. - - / / / �/ h / / 1 �� i• ••\•\ I I � i I `+�.� --� \ \ \ \ \ \ \ \ \ \ � FLOOD HAZARD AREA \ 1 \ \ 1 \ \ \ \ \\ \ \ \ \ O TEMPORARY CONSTRUCTION EASEMENT IS LIMITS 44 4 h / \\I _ \ \ \ \� \F �� I 1 I I 1 \ \\ \�\\\ \ \ \ \ OF DISTURBANCE. 3` I \ \ 5 INSTALL STEEL CASING PIPE USING TRENCHLESS City of \ 4 \ GVC� er round PERENNIAL I I ` I I / l _ �- \ 1 O METHODS IN ACCORDANCE WITH CONTRACT Loco ee uests JIMMYJ. WHITERKER 1 / \ �� ` STREAM I 1 \ �� AND WIFE I ) / / / 7O'r %// 0 d \ \ O3 S—A i i \ G�' SPECIFICATIONS. ALL PIPE WITHIN THE CASING PIPE NELMA J. WHITERKER / / /r / C� // \ . `3` / I 1 ` \ I I COG Water73-2033 S I I SHALL BE RESTRAINED JOINT PIPE.GDOT Traffi73-2606 58205TARMOUNTRD j "596 i / �/ I / 9�i 1\ICOG/Guilf- 73-2084 RCREID 754, // / Ir / �� �Sg \ \ \\ \ \ I PROP. 24" 11.25' RJ FITTING DEED BOOK1664, PAGE / / - S \ / / 1 O PERMANENT UTILITY EASEMENT IS LIMIT OF COG Wat r upply ----- 73-5855 1496 _ \`s9 r // �' , -596 1 \ \� I FEMA 1 % ANNUAL ,� \ \ \ ` 1 \ STA 418+76 DISTURBANCE. Tanks e tment Plants — a� B r / /r } \ 1 1 FLOOD HAZARD AREA \ ( \ 1 N 772553 - - PLAT�CZOK 59-RA,9E-37 \ / / % / /r 1 I / / � \ r ter _ - - 73 2569 QJ�\ F \ l \ \ \ \� \ E 1816009 O 7 EDGE OF PAVEMENT IS LIMIT OF DISTURBANCE. 0 0/0 8 CENTERLINE OF FUTURE 24" GRAVITY SEWER TO NPDES SANDY CREEK LIFT STATION. NOT IN CONTRACT. S99\ \\ \ 1 11 \ o� \ ` \ \\ $ o� �_ �, \ \ Genercl Permit 00 1510 10 0\ Applies 6.0 o \ 20 Z v�F , WETLAND \ XO _J \PN8 \ \ W-G I o S84\ �F o - so,� 58 A, S� 1 DISTURBED AREA — / \ F AT' 14.76 AC \ F co GI S DISCLAIMER III / / -a/� / //� cos \ \\ I ( � �\ /' ,�.- �`• Objects on this map shown 0095E(P-05805C-06) \ i �`.�I with a dotted linestyle were I/ /r / / \ ` I 'h not surveyed, they were / / / I / / °a� -60) 0005 (P-05805E-07) I � \\ �\ / // \ \ 0001(P-05805E-06) ��� I �\ compiled by photogrammetric 608 \ \ � RCREID 82926 � � �� � �� � � � �`� �` methods, available on the DEED BOOK 2438, PAGE 1149 / i �\ i �`� Geographic Information System (GIs) software used spg\ \ \ \\ PLAT BOOK 138, PAGE 68 7 �\ by the City of Greensboro. 6A� OY Ns. O O O 630 a U) 620 610 PROFILE OVER 600 24" C-900 D CE MAIN EXISTING GRAD 590 580 570 560 550 LU J U Q HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 INSTALL 24" FORCE MAIN AT A DEPTH REQUIRED TO PROVIDE A MINIMUM COVER OF 4' BELOW EXISTING GRADE LL �-) N N N � ALL PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1% OR,GREATER O 0 + N d -4 of � a_ C/) 72" RC 24" GRAVITY SEWER PIPE 72" RCP WITH 36" STEEL ENCASEMENT -1 4 V 36" STEEL CASING PIPE, 0.375" WALL THICKNESS 410+50 411+00 411+50 412+00 412+50 413+00 413+50 414+00 414+50 REVISIONS TYPE ROADWAY 1 SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK (D z 1= C� z I (D Z L Q Z LL I u_ L� c �00 12� +° Lr) + ° 1.0 Lr) + ° 1.0 Lr)(0 N N N N N Q N Q Q N (n N (n N U) W N 1.0 a_ + � o w c~n W W W coa M " C- 00 DR18 PIPE Q' OD + 00 w(0 m(0 I 620 610 M 590 Z_ 580 570 ALL PIPE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GREATER I 560 LLI 550 J U a 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET 037518 .10/26/2023 c % �'�•. TyEtiV W �P�'� z K- 415+00 415+50 416+00 416+50 417+00 417+50 418+00 418+50 419+00 419+50 CONTRACT CONTRACTOR AS —BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805C CITY OF GREENSBORO DESIGNED 8/2023 BY MAs WATER RESOURCES DEPARTMENT 2022-013C CONST. SURVEY BY GRMS Phase IV Sewer Force Main Extension 24" FORCE MAIN STARMOUNT ROAD/PARALLEL TO GRAVITY SEWER CHECKED BY PLAN AND PROFILE SCALE: AS NOTED STA 410+00 TO STA 420+00 04C-17 SHEET NO. 21 OF 43 z� O REFER TO SHEET 04E-09 O FOR EROSION CONTROL O QI co/ \ PROP. 24" GATE VALVE — n STA423+25 N772117 2 �� �/ 1 I _ 1 �J► E1815907 O i � r�� PROP. 24"-- 00 DR1&fORCE MAIN _ Z s FM �. \-58s �\ EE\����L- /� / // ///--- iU--�� 587-- _ \ \ — $�� \ \ _ _ _ _ ——/— -S8 \ FA4 \�22`��—\` \ ��\ �\ _— 5g i= — 9 /,b 3-�_ /�/�L/E—���E��E 590— 4 -/r -- \-586----` \ \ - 7. �\ �F � `4•�+00 - -�_ � '-�— \-� ESE �588- 89590 - F - _--S9424A0p \i / /--� E E� �585— LLI w __-----_-� \ - \ 1 AA - �1� - 425+00 \ \ \ - - 5 — — — E E -� / F- J 58� FM \ 'S88 �426+00 g� �,L L E 584 �`---�•---� =C� L� \ _____-__--- 6 - - - N FM F 427+Qg _- �__,�l ----_------------ \ - --�.y� 6 \ _ - - M 428+0I = _ E —------------- _�\ — — — / -5� F 429+00 — — — /4 11" FM LU IFM PROP. FORCE MAIN `" 1 5 _ FEMA1% ANNUAL \ AIR RELEASE VALVE _ \�' ------------- ____ __ _ + � -'- � p FLOOD HAZARD AREA --__ (COG STD. 211) \ STA 423+36 — — — - - ---4------------ N 772105 ---_� J wF---- \ E 1815905 N ILL. \ \ zm oz \ — N Q o N Q PROP. 24" 22.5° RJ FITTING L 610 STA 429+67 N 771486 E 1815788 GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. DEFLECT PIPES AS NECESSARY PER MANUFACTURER'S RECOMMENDATIONS TO MAINTAIN ALIGNMENTS. UCENTERLINE OF FUTURE 24" GRAVITY SEWER TO SANDY CREEK LIFT STATION. NOT IN CONTRACT. OPROVIDE 2'x2' CONCRETE PAD AROUND VALVE BOX. OFLOOD PLAIN INFORMATION PER FIRM PANEL 8717, MAP NUMBER 3710871700J, EFFECTIVE DATE 1/2/2008. FLOOD ELEVATIONS VARY FROM 586 FT. TO 582 FT. NO ADDITIONAL 1% FLOOD HAZARD AREA IDENTIFIED IN THIS LOCATION. 4O TEMPORARY CONSTRUCTION EASEMENT IS LIMITS OF DISTURBANCE. OPERMANENT UTILITY EASEMENT IS LIMIT OF DISTURBANCE. O O O C'7 620 Q H 07 610 CONTRACT SHEET ?? OF d-� SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. N o rah 8� CaroliMwviw.�n�a� city COG Water eso s e 73-2033 GDOT Traffi Si _ — — 73-2606 COG/Guilf rd C . elecom — 73-2084 COG Wat r upply _ — — — — — 73-5855 Tanks e tment Plants GDOT St r ter _ — — —-3'73-2569 NPDES Genercl Permit Applies DISTURBED AREA 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted linestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIs) software used by the City of Greensboro. 40 0 40 80 HORIZONTAL SCALE IN FEET 10 0 10 20 VERTICAL SCALE IN FEET J >� W (n N Q COCO CO M 600 LU LO M 0 - v 600 0� p Q g PROFILE OVER Q U 5 U)0� 24" C-900 DR18 FORCE MAIN EXISTING GRADE 590 590 oz oz 580 580 w w 570 Ln N a- Ln N 570 + a + Z N to N U Q I w W W 1.---Q fT] (n z a-W W + Z a- + 0')560 J z - 560 Q Q + w l- m cn � r` z 1.--- W cn C-) I 0') U N Q Q Cl)550 64 INSTALL 24" FORCE MAIN AT A DEPTH N 550 REQUIRED TO PROVIDE A MINIMUM •N ,CAROz % COVER OF 4' BELOW EXISTING GRADE .` � ,��.� ESS 540 LU Z_ J U Q ALL PIKE SHALL BE INSTALLED ON A POSITIVE SLOPE OF 0.1 % OR GRE 420+50 421+00 421+50 422+00 422+50 423+00 HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 423+50 424+00 424+50 425+00 REVISIONS REVISED PER NCDEQ COMMENTS 100% SUBMITTAL ALL'PIPE SHALL BE INSTALLED ON A NEGATIVE SLOPE OF 0.1 % OR GREATER I 1 1 425+50 426+00 426+50 427+00 427+50 428+00 428+50 TYPE CONTRACT CONTRACTOR AS -BUILT AUTH. DATE WATER AND SEWER PERMITS ROADWAY SEWER 2022-013C WATER SIDEWALK Al LU 540 Z_ J U z K- 429+00 429+50 JOB NO. P-05805C CITY OF GREENSBORO DESIGNED 8 2023 BY MAS WATER RESOURCES DEPARTMENT CONST. SURVEY BY GRMS Phase IV Sewer Force Main Extension 24" FORCE MAIN PARALLEL TO GRAVITY SEWER CHECKED BY PLAN AND PROFILE SCALE: AS NOTED STA 420+00 TO STA 430+00 037518 08/21 /2023 /-EINW- ,,,�. 04C-18 SHEET NO. 22 OF 43. 16, kFj /// �. \�\;\\\� ���,// I� ti / ll ► STA 256+55 BEGIN PROJECT 0074N / QCOD \ \�\ /� // /�// \ IP \�\ / / / I / , GREENSBO075E DOLPH GILMORE LANDSCAPING, INC. / // �� \ �'% �'�//� ��\// I �� \ MEGASITE FOUNDATION, INC. 9144 9154 OLD 421 RD GCPN 0123460 / // / / / / / ����\\ /■♦��■ / 4621 IRON HORSE TR / p / / / \\ / \■■ ♦ , DB 7032, PG 2896, TRACT 2 \ / / RC REID 74069 / ��/ �/ � � / ♦ ■• ♦ / DB 2491 PG 1186 RC REID 74073 / / / /` // / / /�� � ♦ ► �+ �� / / ♦ � DB 2136, PG. 1529, TRACT 2 /\ // /3 / / / '� ♦ I �\/ PB 121, PG. 43, TRACT 1 _ _ -� / /\"// / l ♦♦\ tiQ� ♦♦, p \ ♦ SENSITIVE CONSTRUCTION AREA WITHIN B- �■ ��♦ ♦♦; \ ` - LOD OF DRAINAGE AREA, SEE SHEET OOG-01 FOR SPECIFIC �\'6 �� \ ;�� �Q� / ♦ CONSTRUCTION SEQUENCE / / // / / \ \ I ♦ 1`��8 �� ` / $ ! \ 3 \ / 0076E / / l/// / ,// / �ti ♦ 4 '9C ��� / \ \ GREENSBORO-RANDOLPH \ _ - / / / / /�d'/� // \ \ J / �\ \ ♦ ���\ \ \ \ %�\ ♦ MEGASITE FOUNDATION, INC. /et i \ \\\ ♦♦ �,q�\ \ \ 4622 IRON HORSE TR / ♦. ♦♦ C ! RC REID 85619 / / ,A ♦ (. / / ♦ / DB 2492 PG 1492, TRACT 2 �41) /V/ Ilk ee :Aj / / / / / / / �� • / PROP. WATTLE s COG STD. 457, TYPICAL \\ // / / / / ROGER DALE ASHLEY 6135 JULIAN AIRPORT RD / \ a\\ ♦ \\ v ♦ / / RC REID 74064 DB 1116, PG. 25 =° \� \\ �♦ \ / /� / / / SEPTIC DRAIN FIELD-7<I /,01 `� \^+ �♦ I / P-750 ♦ \ ♦ �� \ � i/ p. NZ _ � -ale-\ / / C /// / / / / - / / /� / // / / \ / \ ♦ � 0074W ROGER DALE ASH LEY 6135 JULIAN AIRPORT RD RC REID74064 DB 1116, PG. 25 0076E (P-05805C-O6) 0077E (P-05805C-06) 0078E ( MANUFACTURING, I TOYOTA BATTERY MANUFACTURING, INC. TOYOTA BATTERY TOYOTA BATTERY MANUFACTURING, INC. TOYOTA BATTERY I 5938 JULIAN AIRPORT RD I MANUFACTURING, INC. 5950 JULIAN AIRPORT RD MANUFACTURING, INC.. 5990 JULIAN AIRPORT RD I RC REID 74052 RC REID 92593 4622 IRON HORSE TR RC REID 74084 I DB 2810, PG 1683; (5) PARCEL 75 OB 2810, PG 1683, (5) PARCEL 16 DB 2810, PG 1683 D8 1011, PG 138, NCDOT R/W Z RC REID 92504 DB 1782, PG 2430 (VERIZON WIRELESS TOWER I DB 2810 PG 1683, (1) PARCEL 53 I I AGREEMENT) PB 121, PG 27, LOT 1 (5) PARCEL 15 DB 2648, PG 325, COG UTILITY EASEMENT I DB 1011, PG 128, NCDOT RIGHT OF WAY I D8 1011, PG 138, NCDOT RIGHT OF WAY I DB 1011, PG 146 NCDOT RIGHT OF WAY D8 1515, PG 25, DUKE POWER COMPANY EASEMENT DB 1736, PG 2416, DUKE POWER COMPANY EASEMENT PROP. WATTLE COG STD. 457, TYPICAL SENSITIVE CONSTRUCTION AREA WITHIN I LOD OF DRAINAGE AREA, SEE SHEET OOG-01 FOR SPECIFIC - - - - CONSTRUCTION SEQUENCE - -744- - \- I I \I I I I \1� J w a1 I CE CID 745 o Q a Q 1 \ TREES II I I 1 \ - \ - \ \ I \ ^ a � w � I IQ 1 \ \ 74s- � / L GT � TREES - 0 v I I ► I I I ` I I LTI NV. 738.72' -746 \�I T�S \ Q JI _ -, I \ \ ; \ I 1 I w �■�■■■■�■■ r � �NV. 73t.16' to \ \ 15" RCP \ FOC ■■■'■■� o •L<- I 11 r o \ \ Inv In 746\08 I \ 1 I MKR D- ■■■■■■■■■■■ INV./�/43.11' INV. •1�A�1* /� x GENERAL NOTES: 1. SITE TOPOGRAPHIC SURVEY WAS PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. LOCATIONS OF EROSION AND SEDIMENT CONTROLS MAY NEED TO BE ADJUSTED BASED ON FIELD CONDITIONS. 3. CONTRACTOR SHALL NOT PERFORM ANY WORK WITHIN WETLAND AND STREAM AREAS UNTIL 401/404 PERMITS ARE RECEIVED. 4. NOT ALL KEYED NOTES ARE USED ON EACH SHEET KEY NOTES: 0 20'x10' LAUNCHING PIT, TYPICAL. O2 10'x10' RECEIVING PIT, TYPICAL. OPROVIDE BERM WITH SILT FENCE ON OUTER EDGES AROUND BORE/RECEIVING PITS TO REDUCE INFLOW. 4O PITS SHALL BE DEWATERED USING SILT BAGS BEFORE WATER IS REINTRODUCED TO THE CREEK. EROSION CONTROL NOTES: 1. CONSTRUCTION SHALL BE COMPLETED DURING TIME OF LOW FLOW. 2. WEATHER FORECAST SHOULD SHOW NO PRECIPITATION FOR 48 HOURS AFTER COMPLETION OF STREAM CROSSING. O •• • I I I 11 0 \ TREE � ► \ Inv. Out 745 ,48 / \ 1 I AND � �.■■■■■■■■ 1.70 AC / �ZE _ l C7HgDa�HO •`/• -�� - - _ CD ` •• I\ I 11 GUY I \ I I / \ \ \I yi.liL�►■■■■ / _ , �- - �_ _ - 268+ �8"1I�D - -6S �= _ + �0)• i• I 11 \ I 11 I 1 \ / / -� ♦• • `� _ -tSb- _ - _ N . P / I_ - _ ■■■■■■■■■■■�f■■ ■■■■ ■ ■■ ■■■■■ L..��FOC-� - - - - - - I N Fes- I I I Q -_ NUNNLOB - - ' ■ / 2 /ill Fac -_- ^� arm _Sao /pDR _ IPL� r\r�•�•■•�• 12 RCTs \ \ VP __ _ -<---- _ _ DRY' = PIPE��j_� ' '\IP� - ./ I _ _ OH/P I�PE 1�18�r�� ■■■■■■■■■■■■■■ �i■■■■ Sifi•■1�■■16■■■■■■■■■1■■■■■■■ 1} --- ---- -- \ Inv_ Out 751.45 - 2MB - - - ""-�� DR OMB-- - - - - = - - - - - I IP� / / pp off aH I /P D R °fy(r� J I P \ OH/P OH/H - - OH/P OH/P I l _ \ ` - c - - - IPE °f+iP TEL O1/P I OH/P OH/P OH/P PP , ; - - . I I I, 1 4 I 1 / / / Z I I I PP 11 I \\ I I / ► I ► '_�/ 1' ► I� I III \ \ \ I I I / / / ► ► / I I i7 45 I 1 I \ n\ / 1- I Hx / \ I I\ 111 I I I �/ I ►/ I I / I I I►� / 1��/ --In,\\ I \ \ \ ► � / I / I � � LJ SHED \ �I I / / / �� 745 -� I I I I / I I I \I MBH I 1 I I \, - - MBH O - L \ I I A I � \ I I I I I / // �j l/ • C? •� � _ I I I \ TR7S i I I / / I / / i I I PP 1-SBD \ MBH O US / O ►�+ U U HER Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK CONTRACT ICONTRACTORI AS -BUILT IAUTH. DATEI WATER AND SEWER PERMITS 2022-013C JOB NO. P-05805C DESIGNED 11/2022 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED CONTRACT SHEET 24 OF 43 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. Mortholina www.nc811.erj , City of',Gree or �erbround COG Water e c 73-2033 GDOT Traf is 73-2606 COG/Guilf rd Co. Telecom - 73-2084 COG Water Supply -- - - - - ,73-5655 Tanksl�Tr atment Plants GDOT Storm ter--_--373-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a doffed Ilnestyle were not surveyed, they were complied by photoArammetr1c methods, available on the Geographic Information System (GO) software used by the City of Greensboro. 40 0 40 SCALE IN FEET LEGEND: 50' BUFFER STREAM ®EROSION CONTROL MATTING R DRAINAGE AREAS ■ SILT FENCE 00 TREE PROTECTION - LOD - LIMITS OF DISTURBANCE TEMOPORARY CLEAN -TD- WATER DIVERSION SILT FENCE ROCK OUTLET WATTLE TEMP STONE DITCH CHECK DAM CONSTRUCTION ENTRANCE K- CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension JULIAN AIRPORT ROAD AT OLD 421 ROAD EROSION CONTROL PLAN FORCE MAIN STA 256+00 TO STA 269+50 FUTURE CONSTRUCTION `.,•N CARO EA 4 =z 18 SO A J ■' rrr••,/t��7 'G+'�y IN '�j� :1 04E-01 SHEET NO. 24 OF 43 I I / I I I I I I I I 0080E (P-05805C-06) I 0081E (P-05805C-06) 0079E (P-05805C-06) I TOYOTA BATTERY MANUFACTURING, INC. I ' TOYOTA BATTERY TOYOTA BATTERY MANUFACTURING, INC. � I 5742 JULIAN AIRPORT RD I MANUFACTURING, INC. 5938 JULIAN AIRPORT RD RC REID 74080 5772 JULIAN AIRPORT RD "90� RC REID 92593 I DB 2810, PG 1683; (5) PARCEL 76 I RC REID 74040 i DB 2810, PG 1683, (5) PARCEL 16 I DB 1011, PG 147, NCDOT RIGHT OF WAY DB 2810, 1683; (5) PARCEL 78 ��/ DB 1782, PG 2430 (VERIZON WIRELESS TOWER AGREEMENT) DB 2648, PG 325, COG UTILITY EASEMENT PROP. SILT FENCE PB 54, PG 40, LOT 1 DB 1011, PG 146 NCDOT RIGHT OF WAY I D8 1515, PG 25, DUKE POWER COMPANY EASEMENT PROP. WATTLE STONE OUTLET DB 1736, PG 2416, DUKE POWER COMPANY EASEMENT COG STD. 457, TYPICAL i PROP. TEMP STONE DITCH COG STD. 430, TYPICAL PROP. TEMP STONE DITCH CHECK DAM CHECK DAM i SENSITIVE CONSTRUCTION AREA WITHIN I COG STD. 432 COG STD. 432 PROP. 40 LF SILT FENCE COG STD. 430 LOD OF DRAINAGE AREA, i / �\ PROP. 50 LF SEE SHEET OOG-01 FOR SPECIFIC / I / �j TREE PROTECTION/ / CONSTRUCTION SEQUENCE / I I BRUSH / CONSTRUCTION FENCE / / II I / / / / / / / �' I I / I wll / / � ^ti I / \ PROP. 320 LF SILT FENCE � ,•n ( I /I I /� / / COG STD. 430 i / / \ _ 10 — / I I 0 O HLLt i / PROP. WATTLE / r COG STD. 457 0-)^`U ti / / I I I / / I 1 PROP. 150 LF TREES / / j = ■ t-IVI N , / ^ / �/ ti ,� I I I < I \ I TREE PROTECTION/ — — \ / ti /� / / I/ I • �� Q / FIBER-QPTIC /CABLE / / / / / / ^N ^ / I �' I \ I \\ \\ CONSTRUCTION �TION FENCE II ' I _ \ / y I I / ANDH9LE / / / / / / I / ) IN�. 71lS.P' a /II I' I / / / /I I PP I v C7 / / / / / / / / 3 \ \ � �` Z ATE INV. 715.33' — — _\_— — — \ _ L. — — _ l r ■ stQQ ■i r■�■� _ILI _ - - - - - _ - - W —_ ` _ _ `� _ �7 I-j _i _'G`MP — _ _ _ _ _ HOC FOC FOE— FOC fGC ADO — — �� ` _ — FOC— FOC- FOC— FOC FOC— FOC— FOC— FOC FOO— F�(',�F00— FOC ►ur—, U ,,.— FOG=.w� _ —� FOC— FOC— — FOC— FOC FOCI FOir -�. .. ■� ■ : T~ _E L-0B ALA[ 15 " RCP € / ■ 0.09 d`E 0.08 AC ����� ���� Q■zrriliii■■■■ /■■■■■ ■i�zr■ ■Mf'L�� ■■■■■■ f■■■■■■■■■■■■■■■■■3tL■ir■P■■■■ t ■l�I�. I11•�Y'!�!7�'B•� 1 ■ ■-■ff f■� - - 0 I ) l l l 'Li= � 7585. 53 Iri 73 5�' ■■■■■. I Out 714. 44 \ LL ^ - _ Inv. Out 710.47 / ■■■■ ■■■■■■■■■■■■■■■ — — __ --- — //-782357 9 Ex. CON APF�ON _ _/_ ___ _ / _ _ _ ___ _ LL---_--- _ ______ _ -- --- --_ -` T _T— T -t _ =r =r-T - T T\� /� -T -T -ice '-Z _c \ T-------------- i -722 �f T—�T—T T- —T—T \//'— -� — DR( T /�,� D� 4MB— i _ .- n D \Z-iT��t —_ — —___ — — ------ _ — — \ DR PIPE f/�------�'� \ \I I q------ i\PIPE �� c�_�z4--PIPE\ ��F� — �— ` --- _ ---_ c \ ---- ��—_ Y — ---- Q ✓�( — I® r� — ---- X/ \ 1 P POH/P; %/P —p/P �OH/P OH/P OH/P OH/P yOH/P H/P ON/ I ON/P OH/P( /\ 2 4 � OH/P PP 1 4 3 �a �OH/P OH P\� /P P 1\ I /P wt -P �'� �H� Ir I OH/P J/P OH I I OH/P OH/P OH P DHX�/P OH/P3 PP \ � 1 I 1 \ I I ► \ TREE \ I m \o Lu ( II I \ \ \ \ I I \ \ Z=�� I I I �I11 II TREES / /I -x —/X— () CH IN LINK —FE_NCE BRU\ MBHSH III III II I \ I I 1 - i 1 I I PP 1 SBD \ lit >1 Q V A i � 8 I � I 1 I I\ \ T� T9 PROP. TEMP STONE DITCH \ CHECK DAM COG STD. 432 I _ — ♦♦� E (P-05805C-06) ♦ YOTA BATTERY \ %` PROP. 215 LF SILT FENCE ♦♦ ANbFACTURING, INC. COG STD. 430 ♦♦♦ RC'REID 74075 \ _ ♦♦ 8 2810, PG 16' 3\ 2) PARCEL 55A \ \' PROP. SILT FENCE I \\ \ STONE OUTLET ♦♦♦ \\ \I I I .�. COG STD. 430, TYPICAL \ PROP. 170 LF OSILT FENCE COG STD. 430 _ _ �♦ ♦ � y+,+1 � PROP. 50 LF ♦♦ I \ \ y+r:s \ ,� TREE PROTECTION/ \ �+ \ \ / 0 rnNlcTRI IrrTlnnl FP:NIrF GENERAL NOTES: 1. PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. LOCATIONS OF EROSION AND SEDIMENT CONTROLS MAY NEED TO BE ADJUSTED BASED ON FIELD CONDITIONS. 3. CONTRACTOR SHALL NOT PERFORM ANY WORK WITHIN WETLAND AND STREAM AREAS UNTIL 401/404 PERMITS ARE RECEIVED. 4. NOT ALL KEYED NOTES ARE USED ON EACH SHEET U 20'x10' LAUNCHING PIT, TYPICAL. O10'x10' RECEIVING PIT, TYPICAL. OPROVIDE BERM WITH SILT FENCE ON OUTER EDGES AROUND BORE/RECEIVING PITS TO REDUCE INFLOW. 4O PITS SHALL BE DEWATERED USING SILT BAGS BEFORE WATER IS REINTRODUCED TO THE CREEK. EROSION CONTROL NOTES: 1. CONSTRUCTION SHALL BE COMPLETED DURING TIME OF LOW FLOW. 2. WEATHER FORECAST SHOULD SHOW NO PRECIPITATION FOR 48 HOURS AFTER COMPLETION OF STREAM CROSSING. 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE STABILIZED AS WORK IS FINISHED. 4. LIMITS OF DISTURBANCE WITHIN BUFFER SHALL BE LESS THAN 40' IN WIDTH. PROP. 380 LF SILT FENCE \ \ ♦♦ \ •,o•' \ �' \ �� COG STD. 430 \ / ♦♦♦ I vo PROP. 188 LF ~ \ ♦♦♦ �QO �. ♦♦ \ / / \ �� TREE PROTECTION/ :♦�\/ ; �� .♦♦♦♦♦ �\ y// \ \ `��qX CONSTRUCTION FENCE ♦♦ � 0. ` �yy r . ♦♦ O /I / Q� / \ \ \ S \ \ \ I Y � \\ // // / �� �°ate \\ ����� • �l I �� / _ � \ � \ 0. 7 '0 :Q9 AC • a / ■ 0 ♦♦ ♦� Alka \ l I SyFO LOD 0 — — — 000 \ v �13\�\\ 1 \ �' oQ , LOD ■ p / 00 LOD ass 0 a LOD as noon on -6sc Q� OD OD �� \� •1• LODr-154 / I PROP. 52 LF / 2ti / �� \ ••••••� L / l' ,291) U.97 AC / / / I\ ■■r I I TREE PROTECTION/ / ~/ co ••♦„ OD LOD I / / ♦.♦■■�� ••••r•• •• I CONSTRUCTION FENCE , � It Ott pp Ill, 44 7- LOD a LOIT Ross* All c9Q\ �I� ♦ % / // / ♦ / / / i I I ♦••♦♦♦♦ / 000// } �� _rY \� I pE\ / / ♦ J / J ♦♦'� may'// / �� \ �I 0j \ •♦ PROP. 204 LF ♦♦ / / I • Q N l l \ r \ \ ` ♦♦ TREE PROTECTION/ ♦♦♦ /// / i I i I / Q �i•♦ ♦♦ / // q� (; y / /� i At N IRPORT RD SR 2502 CONSTRUCTION FENCE ♦♦ / ( / I _ I Q hA_ •�♦ ♦♦♦♦♦ _� / l I ♦♦1 / / 1 tyO 45 ♦♦♦•♦♦� / / / a� \ �� • / / ♦ / / / % / T p� C, .dT , I 0085E P-05 05C-0 1 l � \ _ � r \ •• \ ♦ / / LLMAN, IA TT 7,/O �� \ •••••• l l / .♦♦j l / j / / I / �7 �9N�F / I GELL�GIA(V, BREYANN ICOLE) \ / yglN �x �7 ,\ \` \ �� \ •••• / / Q ♦♦ / / / /1 I May I ' JU�Li AIR OR RD / q r '�J \ r ••• 0083E (P805C�6) j r S \� �.\ hje �� 0 J \ r I((`11 \\ �� r \ •••• 715 1� / / / /l // TOYOTA BATTERY / i N \ R 7 REI 9 14 FN Tp �� c� \��\ \ ••• •• ♦.♦ /� �n / MANiJFACTUR G, I / T \ DS 699, P '1474 \ \ \ rZ0 / \ C"�' x \ Ste r\ 2s� \ \� ac \ \ •••♦•• ♦ ♦♦ Q / h`� / / / / 57 TULIAN AIRPOR'rRD I / / l y( / \ \ `/ZB 162, G 5A5, L6'T l \ / '1 / �°HiP \� \ •• ♦• l / a / D8U160, P 1110. CESS E�.SEMENT / i i \ �) \ r • G� lam/ / / RC READ 7403 I �/ — \ RCp / /Q/ /68 2810, 1, 8BZ (5) PACEL�� I \ / �/ / \ D598, l� 2 , QUKE EN'&RGY C/�:\ i O_ i i i / I I r `/� / \ O�RTIO EMOPgNDUM\ \ 0082E (P-05805C-06) 0082E (P-05805C-06) ` \ \ r\ , l TOYOTA BATTERY TOYOTA BATTERY , / / MANUFACTURING, INC. MANUFACTURING, INC. / 5742 JULIAN AIRPORT RD RC REID 74041 / RC REID 74080 DB 2810, PG 1683; (5) PARCEL 77 ,pp �l l DB 2810, PG 1683; (5) PARCEL 76 PROP. 208 LF SILT FENCE y COG STD. 430 / / PROP. 99 LF SILT FENCE COG STD. 430 Y C, \\ HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1000 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE CONTRACT CONTRACTOR AS -BUILT AUTH. DATE WATER AND SEWER PERMITS ROADWAY SEWER 2022-013C REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK JOB NO. P-05805C DESIGNED 11/2022 BY HDR CONST. SURVEY BY CHECKED BY SCALE: AS NOTED CONTRACT SHEET 25 OF 43 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. North 8� Carolina www.nc811.org� , City of', Gree ro erground Locates I o I e uests COG Water R e 73-2033 GDOT Traf is c _ _ _ 73-2606 COG/Guilf rd Co. Tecom _ 73-2084 COG Wat,'er Supply- el _ _ _ — _ ,73-5855 Tanks'/Tr atment Plants GDOT Storm ter--- — _I -2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER ObJects on this map shown with a dotted Ilnestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIST software used by the City of Greensboro. 40 0 40 SCALE IN FEET LEGEND: 50' BUFFER STREAM EROSION CONTROL MATTING DRAINAGE AREAS ■ SILT FENCE 0 TREE PROTECTION — — LOD — LIMITS OF DISTURBANCE —TD— TEMOPORARY CLEAN WATER DIVERSION SILT FENCE ROCK OUTLET WATTLE TEMP STONE DITCH CHECK DAM CONSTRUCTION ENTRANCE K— CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension JULIAN AIRPORT ROAD AT WOODVERY DR EROSION CONTROL PLAN FORCE MAIN STA 269+50 TO STA 289+50 •a'tN CAf�O FA D �./ /� Dk K A J ■' 7�.. M. Yk%A "N,j1,1µN����� :8 04E-02 SHEET NO. 25 OF 43 \ ♦ I l l / / / l / // / / / / ' / �' / / / / — '� — JAMES K. GEORGEVICH,♦ \ \ \ \ I I I I I ♦ / / / / / / / / / / / /' /' / / ��e/ c� \ AND WIFE I I I \ I I I I I I I ♦ 0084E (P-05805C-06) l / l l / / / /� DIEOR �♦• •• ♦♦♦♦ l TOYOTj BATTERY l l l / / l / l / l / l / /� / / / / / / / `�' — —leG — \—Gi�460 RUTCHFIFARM RD �♦ ••�••: I I I I I / l / I �♦ / ■ ♦♦ MNRC R C R �4 78UFACTURING, INC! /61, 50, PG 9D9 2810, PG 1683, (2) PARCEL 55A /, leSENSITIVE CONSTRUCTION AREA WITHIN g < o ♦��/ I ��,� I I �/♦I Imo••I••/ • I / I I /•/• l / / / / / / woo l l / / l / l l LOD OF DRAINAGE AREA, SEE SHEET OOG-01 — '■ / • / / / / / ^� o�♦♦♦ ,/ / / / / / / �� �O / // '�/ / / / l I ' / I I ��e� / '4- O FOR SPECIFIC CONSTRUCTION SEQUENCE �\ `6j6 T ' ,♦♦j�♦ / / •�• • / / /• / I I i ♦ ^o 00 // i / �� l / / l I l / I I r s% �� / - \ \ -6j5 / / / / / j�•••�G �'' / / ♦i/� `O�°j �°m �� ti�� / / / l l / / / I I I I I ytiel' 2� / /die _ — 5411 ♦ r♦♦ / � �� N I / I � I PROP. 162 LF SILT FENCE \ \ -6 o ♦♦ / ♦♦ / / / ♦ ` ion �' / o / / / I I I \ \ — s72- i 'o ' '0C16 q� / / ♦♦♦ / / / / /�♦♦ /yrp��g/ ` / cc: v°� /G / / �I I fie, I COG STD. 430 - - \ ` - / ♦�% / / / r %� / // PROP. 89 LF SILT FENCE <°// C0Co /� I I I I I /----\\671- / 6' / ♦i� N �/ ♦♦♦/ / / //de��7/�♦ �/ / COG STD. 430 coGp�Gm o I I l I // /\�67D_ j L, /♦♦ \ 9 / ♦♦ / / �� / � ♦♦♦ / PROP. SILT FENCE / / / e// / / / �/ J \ I \ n / / �♦♦ l g��y / 1�♦ STONE OUTLET /� l l le' l ( / /�// / / ♦• `/' j'/ / / ♦♦i COG STD. 430, TYPICAL PROP. TEMP STONE DITCH / v / -♦ / � CHECK DAM � �' 0 s. 84 / / / F`-��♦♦ ♦♦ / / / / COG STD. 432 \\ \ PROP. TEMP STONE DITCH %�•♦`%9 / AC / ♦ / �"� / / \ \ \ CHECK DAM \ ♦ / / �L — /� / ♦♦♦` //� / / \ \ COG STD. 432 72704t I ♦ I ` \ \ \ \ \ ■ f■■■■Tn■w ale �r ��■����■L����i ��� ...■� LF SILT FENCE — COG STD.4O /�•� I �1 LOD PROP. TEMP STONE DITCH , PROP. 66 LF SILT FENCE \ LO\ \ \ \ �C\\ \ \ \ CHECK DAM (TYP.) / I STD. 430 \ D COG ■ \ \ COG STD. 432 \ \ ZI I I I I I °ale \ ` PROP. 40 LF SILT FENCE \ PROP. 37 LF 6'8q \ �a■ ■ \ \ \ \ \\ \��� \ \ PROP. TEMP CREEK CROSSING I Fi U� U E . U A A R�OR I SR�j%� COG STD. 430 TREE PROTECTION/ \ \ \ \ \ DURING CONSTRUCTION i e re \ \ \ c �k\ - CONSTRUCTION FENCE \ \ \ ♦♦\ \ ��r I � \ \ \ \ � \ � � \ \ \ COG STD. 213 < N PROP. 74 LF SILT FENCEell \ \ \ �Q \ \ \ \ \ \ \ \ \ ♦�� \ \ \ \ \ \ \ \ \\ �� \� \ l \ \\ \\ 1\ \ \ \ ytle \ \ 1 / COG STD. 430 SENSITIVE CONSTRUCTION AREA - \ QQ04 \ \ \ \ \ \\\\ \\\ ♦ �\ \ \\ \ \ \ \ \ \ \\ \ \\ \ICI �S9 \QO l \ \ \ d1r \ \ \ \ / \ PROP. TEMP STONE DITCH WITHIN LOD OF DRAINAGE AREA \ \ \ \�/jT� 1 \�, \ \♦♦� \ \ \ \ \ \ \ \ \ I �I 6S \ \ \ �,�\ \ \ ck� ` \ CHECK DAM SEE SHEET OOG-01 FOR SPECIFIC PROP. 252 LF ` ,��/��- ♦ \ \ \ \ \ \ \ \ \� \ \ \, \I �\ 6\ \ �`l \ \ \ b� \ \ COG STD. 432 \ CONSTRUCTION SEQUENCE \ TREE PROTECTION/ \ \ \ I \ \ PROP. 41 LF SILT FENCE \\ \ \ \ \\ \ PROP. 68 LF SILT FENCE'\ \ \ \ \ \ \ \ CONSTRUCTION FENCE `�""J \ \ ♦ ♦♦ I I I II \\ \ \ COG STD. 430 I \ \ COG STD. 430 \ \ �♦♦ I - \ � \ \ \ \ ♦♦ 1 TEMPORARY CLEAN � � \ ale \ \ \ \ `� \ �t \ \\ \ \ \ �: \ \ \ \ \ \ \ \ \ \ : ♦ �♦ \ \ I I t WATER DIVERSION, SEE \ \ ` -� -I - \ \ \ \ fie\ \\ o\v\ \\e\/ \\ \ \\ \ \ �\ \\ \ \ / \ \\\ 6\�d•sl sD I w / D CDETAIL AIL I 1, SHEET 0400836 (f�805C-O6) I D-0I9 \ ELLMAN, rANN rr co ♦♦���cn-. co I I I rn \�6 N, BREYANN,'Ob(fEL!MA 56.1`ANAIRPORTR(�05815C 6)4 op9 UHFIE�Dy)\ yX RC RTSQ41400 �9\\ \ ♦♦♦\ I0 1 1 qLF rD N7LA �11\DB2699,PG1-74— 44\ �\ \ , E�DS \, \\\ ♦♦ \ I I I I I I/l 41� —_--_— -- _ PB 1�G 555LOT 1 ez6P 17d4 ♦♦♦\ \ GAR�GE D8 1160, PG 111 . ACCESS PROP. 86 LF SILT FENCE' -- --EASEMENT,-, \ \ \ \ \ \ \ \ \ \ 9)t 2598, PG 2471DUKE ENER_�➢` \ \ \ \ ♦♦1R \ I I I I I I I I / / COG STD. 430— \ 29P17"O\MEMO'RA\NDUM - - 008• E (P-0805C-06) \ \ \ \ \ " ALFRED M. CRUTCHFIELD AND— �\ WIFE, CAMLA-9.-eRUTCHFIELD \� \\ \\ \ \ 5536.JULIANAIRPORTRD \ \\ \ 1 \ \ \6 1REID81093 SEE CONCENTRATED FLOW �,/ SEE CROSSING CONSTRUCTION �P-058,5C-06J l ITAM�jS K. G ORGVICH, I \ I SEQUENCE ON SHEET OOG-01 /�_`�' _ \ IANDIFEI I�� /' ' P� / / // / i/'' \---651 JUDIA N E. FOR VIC 606 CR TCHFTELDFORM�D I PgREIDII74078 I ` ` PROP. 570 LF SILT FENCE I DB 1950, PG 2104 � � I I\ / \•657COG STD. 430 PB 1-", PG 514, LOJ 2 to / \ I I \ / V / I \ PROP. 88 LF SILT FENCE \ \ /' ' / / // / //� //%h0 �-' PROP. 45 LF TREE PROTECTION/ C \ \ COG STD. 430 /j > \ \+ / PROP. 267 LF TREE PROTECTION/ // / / /// / / FENCE \\ 1 I I \ / / CONSTRUCTION FENCE `fl \ \ \ ��'> rWETL W- / \ �� / / / _ _�=u�ai=- M_r.L ■fir-ir'■■�O�rr�.■■�, grown `�-"CQ�T�L Qt7� 2� \ \ \\ ♦ ♦♦ � �`/ � `\\ L D'� % ---f� \\ \��- --- y _ / PROP. EROSION CONTROL MATTING - - \ SHE I \� \I _ \ �♦ �� .. r' _ /' �' .%'i��`S _ �/' / SFF I)FTAII 5/n4n_n3 / I I � � , I I I °= I I I I I I I I PROP. 139 LF SILT FENCE I g, COG STD. 430 Ln I I I� j Ln J / I PROP. 67 LF SILT FENCE t •• •/ COG STD. 430 I I • j I I � / KD C /�, CO � I to I I I I C,0 I IS) \\LOItnl i\ Co �� ��\��_ �\�\\ / \ \ 1\ \\ II 1•L�I I I I I � I I I / / / GENERAL NOTES: 1. PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. LOCATIONS OF EROSION AND SEDIMENT CONTROLS MAY NEED TO BE ADJUSTED BASED ON FIELD CONDITIONS. 3. CONTRACTOR SHALL NOT PERFORM ANY WORK WITHIN WETLAND AND STREAM AREAS UNTIL 401/404 PERMITS ARE RECEIVED. 4. NOT ALL KEYED NOTES ARE USED ON EACH SHEET KEY NOTES: O20'x10' LAUNCHING PIT, TYPICAL. 2O 10'x10' RECEIVING PIT, TYPICAL. OPROVIDE BERM WITH SILT FENCE ON OUTER EDGES AROUND BORE/RECEIVING PITS TO REDUCE INFLOW. 4O PITS SHALL BE DEWATERED USING SILT BAGS BEFORE WATER IS REINTRODUCED TO THE CREEK. EROSION CONTROL NOTES: 1. CONSTRUCTION SHALL BE COMPLETED DURING TIME OF LOW FLOW. 2. WEATHER FORECAST SHOULD SHOW NO PRECIPITATION FOR 48 HOURS AFTER COMPLETION OF STREAM CROSSING. 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE STABILIZED AS WORK IS FINISHED. 4. LIMITS OF DISTURBANCE WITHIN BUFFER SHALL BE LESS THAN 40' IN WIDTH. LEGEND: 50' BUFFER STREAM EROSION CONTROL MATTING CONTRACT SHEET 26 OF 43 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. N o rtn 8� Carolina , www.nc811.org City of Gree or o �c#er rounc Locates I o uests COG Water e rce 73-2033 GDOT Traf is _ — — 73-2606 COG/Guilf rd Co. Telecom — 73-2084 COG Water Supply_— — — —12�73-2569 73-5855 Tanks/Tr atment Plants GDOT Storm ater_— — — NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER ONects on this map shown with a dotted Ilnestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIS) software used by the City of Greensboro. .8000000% 40 0 40 80 DRAINAGE AREAS HORIZONTAL SCALE IN FEET SILT FENCE 0 TREE PROTECTION — LOD - LIMITS OF DISTURBANCE —TD— TEMOPORARY CLEAN WATER DIVERSION SILT FENCE ROCK OUTLET WATTLE TEMP STONE DITCH CHECK DAM CONSTRUCTION ENTRANCE PROPOSED TEMPORARY CREEK CROSSING DURING CONSTRUCTION HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK CONTRACT ICONTRACTORI AS —BUILT IAUTH. DATEI WATER AND SEWER PERMITS 2022-013C JOB NO. P- 05805C CITY OF GREENSBORO DESIGNED 11/2022 BY MAS WATER RESOURCES DEPARTMENT CONST . SURVEY BY GRMS Phase IV Sewer Force Main Extension 16" FORCE MAIN JULIAN AIRPORT ROAD CHECKED BY EROSION CONTROL PLAN SCALE: AS NOTED STA 289+50 TO STA 310+00 04E-03 SHEET NO. 26 OF 43 -x=x—x—x ..—x—x 0088E (P-05805C-06) ALFRED M. CRUTCHFIELD AND WIFE, CAMELA B. CRUTCHFIELD 5536 JULIAN AIRPORT RD RC REID81093 L) I DB 2740, PC 17 PROP. 185 LF SILT FENCE \ \ \ \ \ \ \ \ 6S x COG STD.430 Cgol— — — — — — — -------Q 2S— ---- ---- 653----- FD \ \ \ S \\ GRAVEL � � �\ \ \ \ \ \ \\ \ \ \\ \ � � 654------ — — — — — — — — — — — — — 6553— �656--------------\\ \ \ \ o \ PROP. 82 LF SILT FENCE _ — — \ \ I \ — — — — 1 _ COG STD.430 �O \ \ I - ` \ OOSSE (P-05805C-06) _ 0089NE (P-05805C-06) I TOYOTA BATTERY ALFRED M. CRUTCHFIELD ti \ MANUFACTURING, INC. CAMELA B. RC REID 75456 CRUTCHFIELD WIFE,\ � I 5536 JULIAN AIRPORT RD T DB 2810, P6 1704, PARCEL 40 I RC REID 81093 \ ` PB 40, P618, RACTI DB 2740, P617 I 1 PROP. 460 LF SILT FENCE O O O N co iY cI I DIDno ()QF I C TDCC 0090NE (P-05805C-G66) TOYOTA BATTERY MANUFACTURING, INC. RC REID 75455 DB 2810, P6 1704, (1) PARCEL 62 PB 40, P618, TRACT II PROP. PERMAMENT CREEK STABILIZATION WITH MAINTENANCE CROSSING COG STD. 214 PROP. TEMP CREEK CROSSING DURING CONSTRUCTION COG STD. 213 100-YR FLOOD ZONE — PROP. EROSION CONTROL MATTING SEE DETAIL 5/04D-03 LLB _ ,�` �`-� —� - _- --z _ I KCC F'KU I tzu I IUN/ Z _ _ _CONSTRUCTION FENCE PROP. TEMP STONE DITCH CHECK DAM (TYP.) I— = __ ___=_—_= ______==_=�2-----=COG STD.432— _�r„r_T,.,.�T��_ - _ T — PROP. WATTLE =_==yam=_ COG STD. 457, TYPICAL _ --- --- — --�ZM----f—_-------- -- r _ —-----—� _-- — GARDRA�L —f — _ --- \ / \ — 650 =—=/e/45�_- -M TIMT HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 l PROP. 194 LF /�( I 0"` 0"I �i1 �I �Go , �N J / PROP. EROSION CONTROL MATTING SEE DETAIL 5/04D-03 �� C -----`mnf L- A --�- EX R/W LINE — \ � i PROP. 271 LF TREE PROTECTION/ PROP. 470 LF CONSTRUCTION FENCE SILT FENCE n�� nTrnnn \vp I V I � 64 �— 3 x ' x— X % — _ x two to tp°� 6A2.��'■■■■■■■ ■■■■■■■..._�.■ ji �;(v 01 6/39 PROP. EROSION CONTROL MATTING _ — — — — SEE DETAIL 5/04D-03 U PROP. PIPE OUTLET \ ; CLASS 1 RIPRAP APRON — \ LENGTH = 42 FT \\ \\ WIDTH @ END = TOB TO TOB \ THICKNESS = 24 IN \� / COG STD. 422 _ -- -------------- _--- PROP. 470 LF TREE PROTECTION/ CONSTRUCTION --- __-- --- -------------- FENCE ---- --- 640 _--- --.------- - ----- -----FLUME REVISIONS TYPE ROADWAY SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK GENERAL NOTES: 1. PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. LOCATIONS OF EROSION AND SEDIMENT CONTROLS MAY NEED TO BE ADJUSTED BASED ON FIELD CONDITIONS. 3. CONTRACTOR SHALL NOT PERFORM ANY WORK WITHIN WETLAND AND STREAM AREAS UNTIL 401/404 PERMITS ARE RECEIVED. 4. NOT ALL KEYED NOTES ARE USED ON EACH SHEET KEY NOTES: 0 20'x10' LAUNCHING PIT, TYPICAL. O10'x10' RECEIVING PIT, TYPICAL. OPROVIDE BERM WITH SILT FENCE ON OUTER EDGES AROUND BORE/RECEIVING PITS TO REDUCE INFLOW. 4O PITS SHALL BE DEWATERED USING SILT BAGS BEFORE WATER IS REINTRODUCED TO THE CREEK. EROSION CONTROL NOTES: 1. CONSTRUCTION SHALL BE COMPLETED DURING TIME OF LOW FLOW. 2. WEATHER FORECAST SHOULD SHOW NO PRECIPITATION FOR 48 HOURS AFTER COMPLETION OF STREAM CROSSING. 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE STABILIZED AS WORK IS FINISHED. 4. LIMITS OF DISTURBANCE WITHIN BUFFER SHALL BE LESS THAN 40' IN WIDTH. CONTRACT SHEET 27 OF 43 SENSITIVE INFORMATION Not to be copied or disMbuted without the express written permission of the City of Greensboro. o rtlhli�na� MN City of Gree ro gc#er rounc Locates I o j� uests 77\ COG Water e rce 73-2033 GDOT Traf is _ — — 73-2606 COG/Guilf rd Co. Telecom — 73-2084 COG Water Supply-- — — — — 73-5855 Tanks/Tr atment Plants I GDOT Storm Water _ -- — 7,/t,73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted Ihestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Information System (GIST software used by the city of Greensboro. LEGEND: 50' BUFFER STREAM 40 0 40 80 EROSION CONTROL MATTING HORIZONTAL SCALE IN FEET 10 0 10 20 DRAINAGE AREAS VERTICAL SCALE IN FEET SILT FENCE TREE PROTECTION — LOD — LIMITS OF DISTURBANCE TEMPPORARY CLEAN —TD— WATER DIVERSION SILT FENCE ROCK OUTLET WATTLE TEMP STONE DITCH CHECK DAM CONSTRUCTION ENTRANCE CONTRACT CONTRACTOR AS -BUILT AUTH. DATE WATER AND SEWER PERMITS JOB NO. P-05805C DESIGNED 11/2022 BY MAS 2022-013C CONST. SURVEY BY CHECKED BY SCALE: AS NOTED PROPOSED TEMPORARY CREEK CROSSING DURING CONSTRUCTION 14EAA iZ 18 K r'•����-gs`GIN�C Mf0i.YA.� I CITY OF GREENSBORO 04E-04 WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension SHEET NO. 16" FORCE MAIN JULIAN AIRPORT ROAD EROSION CONTROL PLAN 27 OF 43 STA 310+00 TO STA 330+00 0090NE (P-05805C-06) 0091NE (P-05805C-06) N \ �' 0091NE (P-05805C-06) / \� 0091NE A (P-05805C-06) \ TOYOTA BATTERY ��` 1 CONTRACT SHEET TOYOTA BATTERY � / TOYOTA BATTERY /'' TOYOTA BATTERY GENERAL NOTES: MANUFACTURING, INC. MANUFACTURING, INC. 2� MANUFACTURING, INC. MANUFACTURING, INC. Q RC REID 75456 i I ""� 28 OF 43 RC REID 75455 � POj � RC REID 75456 •. RC REID 75460 DB 2810, PG 1704, (1) PARCEL 62 DB 2810, PG 1704, (1) PARCEL 40 / _ _ / ,,, 1. PREPARED BY SPATIAL DATA CONSULTANTS, 0� col . � DB 2810, PG 1704, (1) PARCEL 40 DB 2810, PG 1704, (1) PARCEL 99 P8 40, PG 18, TRACT II I PB 40, PG 18, TRACT �\ �0 ,��j "PB-40, ei 18, TRACTI PB. UNREC-2016 (60' RIW I J INC. AND BRADY SURVEYING COMPANY, P.A. BROWN'S MEADOW RD) DURING THE WINTER OF 2015 'ti Kok �4j' — / \ . Q; / - - SENSITIVE INFORMATION 1 Q-: 'Y 2. LOCATIONS OF EROSION AND SEDIMENT Not to be copied or I / CONTROLS MAY NEED TO BE ADJUSTED \ BASED ON FIELD CONDITIONS. distributed Without file 3. CONTRACTOR SHALL NOT PERFORM ANY express written permission of PROP. 887 LF TREE PROTECTION/ CONSTRUCTION \ I / WORK WITHIN WETLAND AND STREAM AREAS the City of Greensboro. - FENCE PROP. TEMP STONE DITCH / UNTIL 401/404 PERMITS ARE RECEIVED. - - � 100-YR FLOOD ZONE CHECK DAM I PROP. 895 LF SILT FENCE 4. NOT ALL KEYED NOTES ARE USED ON EACH COG STD. 430 PROP. SILT FENCE STONE OUTLET COG STD. 432 SHEET O O O COG STD. 430, TYPICAL I + + PROP. 895 LF TREE PROTECTION/ CONSTRULTIONJ,W) O KEY NOTES: FENCE L \ co co _ PROP. TEMP STONE DITCH 120'x10' LAUNCHING PIT, TYPICAL.- R/SINE N INTER�4ITTENT / Q - CHECK DAM STREAM \ I ,� _ I- - _ ► I I =� =� EiF■ COG STD. 432, TYPICAL S-C-183-1— \ _ _ ` 1 4 U7 O 10'x10' RECEIVING PIT, TYPICAL. \ \ ♦ ern- Gp v \ SS a` �� \ SS \ \ S� \ - 623- -622. l� 20 \ \ / / PROVIDE BERM WITH SILT FENCE ON OUTER ` - a' \ \ D D \ \ '¢�l' ♦♦ J o - -� �� �-'� \ } �� 7 - \ \ - \ / ti0 �69 - \ O ') O EDGES AROUND BORE/RECEIVING PITS TO rn i m \ \ \ v� vS \ m - 1333+1, 0 \ \ \ ��� _ \ \ \ \� 35ti�IId� - 0 ' \ \ \ \ \ \ \ \ 635- cr I I I I \ \ \ \ \ ♦ \ \ - / i (�` 6 6 \ \ T \Z\ o I rn I - REDUCE INFLOW. - - 636- \ \ BIZ t City of Gree or er round - - �) 1311 �00 \ \ x X— - - \ \ + co •� Locates I o uests 50 'a' rn .� _ / / \ \ It �0 / r^ O PITS SHALL BE DEWATERED USING SILT +00 — — — — — -- `6q.� So v� v \v \\�v� \\ \ �v� \ �i� S \ S \ \ S \ \ S x \ - . , v` COG Water e rce 73-2033 �30� 6 . \ \\ \ s� \ N m \ s \ \ \\so, \� �s \ \\ems \ \ �� \ 6�0\ �_ D wI _ / - -ONTO �CC SSA s' 9 \ \ ♦� \ \ \ \ \ \ \ EX•�R LIN 6c' \ / THE CREEK. WATER IS REINTRODUCED TO GDOT Traf is _-- 73-2606 %max E NCE� OLL D \ \ \ \ \ \ ♦���� \ ■■ ■"•• \ \ \ -♦ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ / / / \ o \ \ P/D92 L W0� wTRE � / I ` ■■■ � ♦■ter \ \ \ .'� \ \ \ -J COG/Guilf rd Co. Telecom — 73-2084 _* I ��■■■ •• ♦ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ �\ / — — �\ \ 1 \ y 8 COG Water Supply - — — — —— 73-5855 ` 641— _ _ % ■ • r\ \ ♦� \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ / \ \ 4 2\ \ \ \ ♦ Tanks/Tr atment Plants ■■■■■i■its■■■■■■■■■■■■■■■■■■■■■■■■•f■■■�■■■� `— — — — _ — — — — — _ GDOT Storm r---- 3-2569 - - - - - _ _ - - - - _ s'"�■■1r ■ \ \ \ \ \ • EROSION CONTROL NOTES: ----- ����� - --------- -=%yam ���� X-,*EN ■�.■l�■■■����■ \ \ \ 1 / / WOODS*" \ \ \ \ \ \WETLA � / \ m ate 7 ��rrr.r\\ \ \\ \ \ I\w�-1V3- /(• / WO � ------ __-_____—________-� j�� _-sue■.■ \ \ �_ ----- / \ \ \ \•/ • 1. CONSTRUCTION SHALL BE COMPLETED 11J-_-_-_----- _--_--_ _-______ ==== - —_—_ �__- __=�- _-_� ��� �■ _------ - \ \ \ \ \ \■ y/// / /I/ / ,�J DURING TIME OF LOW FLOW. NPDES _Uj _ _ _ _ _ _ _ __ ■ f,� / -' - • • i ■■i i■i■�■i■�■�■■■�■ ■■■■■■ \■■,■ '■�■ �I■I■�� �8� _ // \ I IZ 2. WEATHER FORECAST SHOULD SHOW NO ' ------ - — -`� — — — — __ —__- __ ------ ----------- — .� , ��" ,� I General Permit _ _----- ---- _-- _ -_-- - / / ��� ij -► PRECIPITATION FOR 48HOURSAFTER U------- ---------__--_ ---_ FLUME �- -___-- -_-_ --l / \ ��������_ - _��/9'/ \ I= COMPLETION OF STREAM CROSSING. ' Applies ----_ - -- --- --� _ --_ __ - __ _ --- - _ — - -_ -_----_ -_--_ _ _ Q 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE - - -- - - - = - _ STABILIZED AS WORK IS FINISHED. t-�- _ _- - - 4. LIMITS OF DISTURBANCE WITHIN BUFFER DISTURBED AREA ' SHALL BE LESS THAN 40IN WIDTH. 14.76 AC _------- _ ------ ----------------- \_--I�+1v=62b.95- -- _ _ _ _=__ _ =-----------� - ��� GIS DISCLAIMER E— = _ — _ -------------------------------------------- -- ��' \\ Objecisonthis map dvmnwith a ------- ------- --__-_ ----- __-- __- --_-----------� ---- ,�� _7 _---_�� \ dottedllnedylewererotsurveyed, _Iv2a. z50f'� 6� —t- Ihfy=&�. 58 — \ 1 they were compiled by ----____—/ �I`—\\ \ \ photoprammetitcmethods, --- --- — — — -- ------ --- - — --- ------ _-- b-,l 1— — _ nTf-1\ available onthe Geograph� Information System (GIS) software used by the City of Greensboro. \ 1 LEGEND: 1 50' BUFFER STREAM \ 1 I EROSION CONTROL 40 0 40 80 \ \ MATTING MNiiiiiiiiia I■■■■■■� HORIZONTAL SCALE IN FEET ■ DRAINAGE AREAS \ SILT FENCE \ \ PROP. 1044 LF TREE PROTECTION/ CONSTRUCTION TREE PROTECTION FENCE - LOD - LIMITS OF DISTURBANCE PROP. TEMP CREEK CROSSING PROP. TEMP STONE DITCH 100-YR FLOOD ZONE DURING CONSTRUCTION CHECK DAM O yTDy TEMOPORARY CLEAN COG STD. 213 COG STD. 432 WATER DIVERSION PROP. 985 LF SILT FENCE I PROP. 456 LF SILT FENCE PROP. TEMP CONSTRUCTION ENTRANCE COG STD. 430 SILT FENCE ROCK OUTLET PROP. PERMAMENT CREEK w w COG STD. 430 M WATTLE COG STD. 436 STABILIZATION WITH Ea - PROP. 995 LF TREE PROTECTION/ CONSTRUCTION MAINTENANCE CROSSING TEMP STONE DITCH CHECK DAM p � FENCE / � COG STD. 214 ` CONSTRUCTION ENTRANCE v V r M �I _ 1 ■ 9 C_- J y*U� J PROPOSED TEMPORARY CREEK CROSSING DURING —34�+da \ \ \ ��/- CONSTRUCTION I \ UUG6IU.432 _ 1\ 42 RCP— Inv_In 60 V ��---- ___--- ---_— �� _ _ — — � SIGN IGG SIGN _-------- `- 1 I CUG STD. 43U i W♦.■■■■iiiWit�■■■■■■.-------- ..■■■■■■■■.■■ ` � — in anummoun LU _ i—UME_----------- ----- - - - - - - - - - - - - -- - - - - _ Q ---�-----------------------------__ ----= Inv_ In 608.>a9•� --_ -- -- ---- ---- ---- —_ - --- — — - ------------------------- - — — — — — — — — — - - - - - - - - - — — — — — — — — — - - - - - - - - _------ -------------- ------ -----� �J�-- —� _ --= 24_�GP— — — r r SIGN �I�N-------------------- _-----_ --- —---��-- ________Lf�l\L=E�,j� �� %��� _ — _ �R€€- -- HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK CONTRACT ICONTRACTORI AS -BUILT IAUTH. DATEI WATER AND SEWER PERMITS 2022-013C JOB NO. P- 05805C DESIGNED 11/2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED I K CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension 16" FORCE MAIN JULIAN AIRPORT ROAD EROSION CONTROL PLAN STA 330+00 TO STA 350+00 -04 oFess�p Z ¢ EA 0z v� /aok ygG I Ele0ji WOO 04E-05 SHEET NO. 28 OF 43 O O O Lo M _o 0092NE (P-05805C-06) TOYOTA BATTERY — MANUFACTURING, INC. ` RC REID 75460 DB 2810, P6 1704, (1) PARCEL 99 PB. UNREC-2016 (60' R/W BROWN'S MEADOW RD) PROP EROSION CONTROL MATTING SEE DETAIL 5 SHEET 04D-08 (NCDOT STANDARD 1631.01) PROP. 1,105 LF SILT FENCE COG STD. 430 W061=121►�1a91[e7►1a911ri1MM CHECK DAM COG STD. 432 PROP. 762 LF TREE PROTECTION/ CONSTRUCTION FENCE / 0093E (P-05805C-06) NORTH CAROLINA RAILROAD HOLDINGS I, LLC 5990 STARMOUNT RD RC REID 75464 DB 2489. PG 887. PARCEL 32 PROP EROSION CONTROL MATTING SEE DETAIL 5 SHEET 04D-08 (NCDOT STANDARD 1631.01) PROP. 108 LF TREE PROTECTION/ CONSTRUCTION FENCE O O O PROP. 387 LF SILT FENCE COG STD. 430 Q PROP. 1,060 LF TREE PROTECTION/ I� j CONSTRUCTION FENCE U 51— _ — - 0.48 A C 0•26 _ - - - 358+0 \ i _ \ 3 0.7g AC =x—. —x F - _ - Fl aP a y / --- /s3 1 00 \ \ 6 - _ \63 - / / - - _ _ _ -WOV ilE FENCE '— . (O 7 WIDE ENQ /6� 6 % / -- ---- \ 640 \-----/_�------i(-R%W L— 9 `\ 1 =642-- 642-_�'` \ /� _\o� ___ /----------_ — ��� I I I I m I M I N to I II mass ■■0.11 u■■■■■■i■:■■■■ _ _ _ 650 - J/ w ____ — —_- -- _ -_ _ — -_- _=-_-_-_-_=__--__________________________________________ _______________-_-_-_-_-_-_-_-_ - - \ _ J =-_ _ ----- --_--------------------YECL ME-- ------ ------------------ ---_= Q _635___ _ ------ - ------------- =628.76-------- — (� _ --_ -iJ-= -_---- __--- -_----- ----------1TOP=67 - 635 Q-�- - 630 _ _- _----- _--- ---- ___�- -�— =_-- --- - - - - c�=r r- =— - --- ---__- =--- ---- ---- ----- ---- ___-- US 421 (NORTH D�_ — — ---_ --- ----------------- _-_--- -- _---- --------_ _ ----=__ =----------------------- -- ------------_ — — — — �v 6(----------- —-------------------_—_—_ _ --- ___ — — — --_ _— 630 — _ — — — — — ---- — —---_ ------ ------ ------ _----- _----------____----�— --- _ =j 630 —__— _ _18' RGP -_-------- _- _ — —__—_ — — __ ------------__ - �_--- ------ - --- —------- _TR-- -----640 RE ------- ---------------- -------__ - - -_ i - �i•J= _---------_--_--_ -------- _-------- -- ��� _ 635 — ------ __---_- — _ — ------------------- `____ - \ -- --\-\ - O O 0 CO co `r PROP. PIPE OUTLET CLASS 1 RIPRAP APRON LENGTH = 36 FT WIDTH @ END = TOB TO TOB THICKNESS = 24 IN COG STD. 422 PROP. TEMP SILT CHECK DAM (TYPE AN A-r DIDC nI ITI CT INTERMITTENT STRF"' \ ' L 0093E (P-05 C-O6) NORTH CAROLINA R LOOAD "l-IOLDINGS I, LL 599(2,STARMOUNT RD\ RC REID 75464 D8 2489`R68N87, PARCEL 32 Id T.1.7.1 7.T-411rl111r�T.l\Ind t.1=�I rr Wr 1\rAQ O h / l/� " i + O / /}�C)/'/ / /'' I(n X& Inv. An OU .yD ` \ /Iyv. 0 t 6 1.5d \ \ \ JLL --� ------ ---- --- ---- ---- --�- __=_------------J-----------�- ` - ------ --------------- -- ---- — —635 ----- - -- _-_--------- __--------------------------g---------------- -a --------------- I - —_-_ —___ =___=------------------------ ----_ __ _ _ ........................� 421 (NORTH BOUND)..I_o.r — — — U / /-------- — _ — I� ------------= ��----------------`— —___ =�---— — — — — — — — — — — — LT - - - - - - - - - - - - - - - - - - - - - — — — ——INV=631_76� ME ------------ ------------------------------------- - - - - - - - ---- -------------------- ------ HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK ------------------------ - — — — — — — — — — — — — — — — — — — — 640 — CONTRACT ICONTRACTORI AS -BUILT IAUTH. DATEI WATER AND SEWER PERMITS 2022-013C I Iz JOB NO. P- 05805C DESIGNED 11/2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED GENERAL NOTES: 1. PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. LOCATIONS OF EROSION AND SEDIMENT CONTROLS MAY NEED TO BE ADJUSTED BASED ON FIELD CONDITIONS. 3. CONTRACTOR SHALL NOT PERFORM ANY WORK WITHIN WETLAND AND STREAM AREAS UNTIL 401/404 PERMITS ARE RECEIVED. 4. NOT ALL KEYED NOTES ARE USED ON EACH SHEET KEY NOTES: 0 20'x10' LAUNCHING PIT, TYPICAL. O10'x10' RECEIVING PIT, TYPICAL. OPROVIDE BERM WITH SILT FENCE ON OUTER EDGES AROUND BORE/RECEIVING PITS TO REDUCE INFLOW. 4O PITS SHALL BE DEWATERED USING SILT BAGS BEFORE WATER IS REINTRODUCED TO THE CREEK. EROSION CONTROL NOTES: 1. CONSTRUCTION SHALL BE COMPLETED DURING TIME OF LOW FLOW. 2. WEATHER FORECAST SHOULD SHOW NO PRECIPITATION FOR 48 HOURS AFTER COMPLETION OF STREAM CROSSING. 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE STABILIZED AS WORK IS FINISHED. 4. LIMITS OF DISTURBANCE WITHIN BUFFER SHALL BE LESS THAN 40' IN WIDTH. CONTRACT SHEET 29 OF 43 SENSITIVE INFORMATION Not to be copied or distributed without the express written permission of the City of Greensboro. WN 8� Carolina , www=811.org City of Gree oro er rounc Locates�e� nests COG Waterrce 73-2033 GDOT Traf is _ — — 73-2606 COG/Guilf rd Co. Telecom — 73-2084 COG Water Supply_ — — — — — 73-5855 Tanks/Tr atment Plants GDOT Storm ater_— — — 73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER ONects on this map shown with a dotted Ilnestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic 1111formatlon System (GIST software used by the City of Greensboro. LEGEND: 40 0 40 50' BUFFER STREAM HORIZONTAL SCALE IN FEET EROSION CONTROL MATTING DRAINAGE AREAS SILT FENCE TREE PROTECTION - LOD - LIMITS OF DISTURBANCE _TD— TEMOPORARY CLEAN WATER DIVERSION SILT FENCE ROCK OUTLET WATTLE TEMP STONE DITCH CHECK DAM < CONSTRUCTION ENTRANCE `.,•N CARO % 04 oF�ss�a EA 18 K A J ■' rrr••,/t�•7 'G t f4j/� 7�.. Mf0i.YA.. t.,�► :1' g I CITY OF GREENSBORO 04E-06 WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension SHEET NO. 16" FORCE MAIN JULIAN AIRPORT ROAD (� EROSION CONTROL PLAN Z7 OF 43 STA 350+00 TO STA 370+00 _ cy� 0093E (P-05805C-06) NORTH CAROLINA RAILROAD \ HOLDIN65 I, LLC / h \ \ 5990 5TARMOUNT RD L RC REID 75464 \ \ DB 2489, P& 887, PARCEL 32 / 40 45 \ \ \ \ 100-YR FLOOD ZONE \\ \ \ \ \ \ j // PROP. 201 LF TREE PROTECTION/ CONSTRUCTION / •601 O / / / - - - - \\\ \ \ \ \ \ PROP. 1,095 LF SILT FENCE / // FENCE -6p9' CD \ �\ \ \ \ \ COG STD. 430 c j PROP. TEMP STONE DITCH i DODSONS LAKE _ / / , 611 /-\\ \\ \ \\\ \ \ \ \ \\ \ 11 WE 601.2 CHECK DAM Q \ (O \ \ \ \ \\ V \ \ \ I I P-A-183-1 100-YR FLOOD ZONE _ __ _ ��� COG STD. 432, TYPICAL TT EDGE OF PAVEMENT W h / / �` / / - _ c =j IS TOP BANK �� , / �<� - / SENSITIVE CONSTRUCTION AREA \ \ O to LU \ CIINCRETE FLUME T— — — Weo �_ _ - - - - i - - - - - -PROP. 700 LF TREE PROTECTION/ CONSTRUCTION = _ - F- _- — =�___= �___ — =— Z FENCE -_- --= — — = ___ — — = �_ _ � = --- --- — _ 5=—f _ ------------------ ---=r= _ — — �n��11.g2--� __ = = � _— —_ -- —__ — = = =� =� ____ —— =__= _____====1= ---- =- = = _ _ �.- - = - _ _- -� 38 — ----\ _------___=—------ =_ �— --- ____ --- ----= ��\ \ (xsection — ' --US 421 NORTH B UND \ heet 152 0 \ \ \ \ \ — — _,of 253) I / ■ — — — — — ------ _ _ _ _ — / -- _-- _ _ — —— — — — — — — — — — _ _----------- _ _—------_--_---_-------_—_— _ _ - -------7� _ _ — ____ — — — —---____ ----- --- _ ---- _ --- — — -- _FM -ItdV-636.fs5y-------- ----------- - - - __---------- GENERAL NOTES: CONTRACT SHEET 30 OF 43 1. PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. SENSITIVE INFORMATION 2. LOCATIONS OF EROSION AND SEDIMENT Not to be copied or CONTROLS MAY NEED TO BE ADJUSTED BASED ON FIELD CONDITIONS. distributed witholtt tale 3. CONTRACTOR SHALL NOT PERFORM ANY express written permission of the C of Greensboro. WORK WITHIN WETLAND AND STREAM AREAS UNTIL 401/404 PERMITS ARE RECEIVED. -so4— 4. NOT ALL KEYED NOTES ARE USED ON EACH XySHEET Q KEY NOTES: L O 20'x10' LAUNCHING PIT, TYPICAL. 10'x10' RECEIVING PIT, TYPICAL. / Vj- •\ / PROVIDE BERM WITH SILT FENCE ON OUTER / O EDGES AROUND BORE/RECEIVING PITS TO I �/ \/N REDUCE INFLOW. City ate7atment of ro er 119( round PITS SHALL BE DEWATERED USING SILT7 BAGS BEFORE WATER IS REINTRODUCED TO (� COG Waterrce 73-2033 THE CREEK. GDOT Traf _-- 73-2606 COG/Guilf. Telecom — 73-2084 \ \ ' COG Watery_ — — — — — 73-5855 \/Tanks/TPlants O� \`/7�EROSION CONTROL NOTES: GDOT Storr73-2569 ti/ y _1 V,G —q- SI SA Y. \ \ OPEN CUT AND . \�S\%^ \ 8\� I \ \ REPAIR GRAVEL \ \ DRIVE (3.52 TON)\ 0093E (P-05805C-06) / PROP. 90 LF SILT FENCE NORTH CAROLINA RAILROAD \ \ \ \ s \ \ qC COG STD. 430 HOLDIN65I, LLC \ \ \ \ \ \ �`fl \ II I \ \ ` SEE CONCENTRATED FLOW - I Q I I 5990 5TARMOUNT RD 1 / \ \ \ \ s / \ \ 1 I CROSSING CONSTRUCTION + RC REID 75464 599 Is,�� \ \ \ SEQUENCE ON SHEET OOG-02 - _ cop I II -I- _ \ D8 2489, P6 887, PARCEL 32 \ 1 \ \ s / I \ \ \ \ I \ \ \ PROP. TEMP STONE DITCH- / I \ \ CHECK DAM o \�------I--'/- ( / PROP.313LFSILTFENCE COG STD. 432 TYPICAL 00 C COG STD. 430 \\ ► \ \ \ \ / \\ \ 1 n \ \ \ \� I\\\ \ \\ - _ _ �■■ \ `s�� \ \ PROP. 97 LF SILT FENCE ,�� _ • \ \ 100-YR FLOOD ZONE i COG STD. 430 F \, I• \■■ ` S \� \ / / \,\\\ \ (/ /j ✓,_ \ \ \ PROP. 577 LF SILT FENCE- \ \ ■■■■ \ S9 93 s / \ I I� / I y \ \ ,9 COG STD430 � S . 0.2 \ENNIA� \\— \ IMA THA BLALOCK HUMBLE, MBLE, 1 4PLIFE E5TATE 0STREAM/ �9585TARMOUNTRD0 013 C REID 75474 BOOK 83E, PAGE 25 .--- i------ _ _ _ _ L / Mph \ \ �/ � � \ \ 100-YR FLOOD ZONE PROP. 700 LF TREE PROTECTION/ CONSTRUCTION _ FENCE i �� ■■■g■■■■■■■■ ' ^/ l / —F� / _ 2 \ 4 — \ I J I �Z l J 00 / AMC —FOCI FOCI FOC--MC--FOCI—FOCI FOCI—FOC ` �■■■■■-1■.Yi� _ TOP OF E WAL ' w Z� �Foc—�Foc�=?de- —a \ \ \ 3 - _ I APPROX INV . 8. 6 ' \ \ \ I 7 \ I I •ua� \ S91' 1 / / / / C�fi Fac �_-1 -1 ■■■■■■ 0.64AC \ k\ 2447- , ram-FI ? _ > M J S \ \ \ \ of 590 • ... \ sir ` —FOC — 1 x \ %ru Name, —r�r fee � __ r/ T�Gi rTr7�r �\'� � — �--- � _-- -O■■ yFoe ■■■■-�■■■■■� \ � \200 \ — Fac�� — — - '• � I ' I \SASS\ \ \� 1\ l — � � / / / I I I I �— / / / / �_ �_ / / / _ / •■ ■■■ ------ AND 24 ^ \ / J /SEE CONCENTRATED FLOW ■■■%----■ -t - - ��ac- - - - - - - - - - R \\ �\ �3 / \ \ / °� CROSSING CONSTRUCTION p -- �- �2 SEQUENCE ON SHEET OOG-02 POC Ln co ru r POO I T OF ALL 7'1 APPHU INV. 8.2' \ \ �� \ \, / 'fir `■ i \ \ \ CTE U' \ `/ IN, \ to I \ED �_ \\ \\ \ \I Ill i =— _ \�\ � r v0094E / —��-- �x \ t0 v / LE5TER LEE RR E \ . . W W . . I // \ 1 _ \\` \\ \ I I I I I \ \ I--- \\\ i cs \ 604 MOUNT RD W W I I / PP \ I \ ' \ 1 I I I 1 I \ \ \ \ _ \ \CD S RC REID 754 \ I I I — — \441 1 DB1962 n\ s p^ Z PROP. WATTLE / W Ile/ I I I I \ ` \ \\ \ \\ COG STD. 457 (TYP.) �V HER Engineering, Inc. REVISIONS TYPE CONTRACT CONTRACTOR AS -BUILT AUTH . DATE WATER AND SEWER PERMITS JOB NO. P- 05B05C of the MCBELarLicen ROADWAY DESIGNED 11/2022 BY MAS NCBELS License No. F-0116 Cha otte, Church 8202 2075200 SEWER 2 0 2 2 - 013 C 704.338.6700 CONST . SURVEY BY REVISED PER NCDEQ COMMENTS WATER CHECKED BY 100% SUBMITTAL SIDEWALK SCALE: AS NOTED 1. CONSTRUCTION SHALL BE COMPLETED DURING TIME OF LOW FLOW. 2. WEATHER FORECAST SHOULD SHOW NO PRECIPITATION FOR 48 HOURS AFTER COMPLETION OF STREAM CROSSING. 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE STABILIZED AS WORK IS FINISHED. 4. LIMITS OF DISTURBANCE WITHIN BUFFER SHALL BE LESS THAN 40' IN WIDTH. NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER ONects on this map shown with a dotted lirlestyle were not surveyed, they were compiled by photogrammetdc methods, available on the Geographic Information System (GIST software used by the City of Greensboro. 40 0 40 MMVE HORIZONTAL SCALE IN FEET LEGEND: 50' BUFFER STREAM EROSION CONTROL MATTING DRAINAGE AREAS SILT FENCE TREE PROTECTION - LOD - LIMITS OF DISTURBANCE TEMOPORARY CLEAN —TD-- WATER DIVERSION SILT FENCE ROCK OUTLET WATTLE TEMP STONE DITCH CHECK DAM CONSTRUCTION ENTRANCE `.,•N CARO OFES51a ~ � Q Z D K A J ■' rrr••,/t��7 'G t f4j� 7�.. M. YA ►, :1' K- CITY OF GREENSBORO 04E_07 WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension SHEET NO. 16" FORCE MAIN JULIAN AIRPORT ROAD EROSION CONTROL PLAN 30 OF 43 STA 370+00 TO STA 390+00 • THA BLALOCK HUMBLE, / i (3.52 TON) OPEN CUT AND REPAIR GRAVEL DRIVE ,1 .•�•• \ LIFE ES TA TE f 1 THOMAS FRANKLIN WHITESELL \ 958 STARMOUNT RD AN RC REID 75474 D WIFE KATHY CHURCH WHITESELL i \ / • LL BOOK 83E, PAGE 25 � � 1 5902 STARMOUNT RD \ / RC REID 75476 i 1 DEED BOOK 1939, PAGE 1917 • j PROP. TEMP ROCK PIPE yy. INTERMITTENT • \\ INLET PROTECTION STREA • j COG STD. 453 yyy y y S-E i \ / � I y yy y • yWEiL y �y • \ Ii II I y - II/1 /•�j /� /% / / � / �/ / / // l// i \\ II PROP. TEMP ROCK PIPE INLET PROTECTION O / COG STD. 453 \ \ \ LLIA\ M 5, O PROP. 334 LF TREE PROTECTION/ \ LYNDA C. D+ E STARECONSTRUCTION FENC547 RC F- i �OAP /�///%� IIII \ ♦ / // / / I ' / I 1 yy �y' \ \ I I ■ / //I /(/ / / // // // // //// // // // //(/(\ / II\ \ 1 \ \ 9\, PACE OPEN CUT AND DED BOOK / � Q REPAIR GRAVEL 5\006 (4.54 TON) CLEANWATER ♦ PROP 97 LF SILT FENCE�♦, F�P�� 1,SN�E \ //� /IIII \\ \ ♦♦ SHEET 04D-06 / / /lI� l l I I y y /� COG STD. 430 P- 0O-\ � - \P\ \� sO9, L\'TD -.QQi5f. /�y///////////I.' ¢Q-O--I I~III II 1♦ ♦I ♦� \ / / // / / // // // / / / / // // l l l lII I acuO ,/ cny /occO>n / - \ Jco \ —0� �t�poI ►o I I OH �/P \ c�B\ \ QO 4P OH/PTOH P OH/ H / �"'0H P I %A J 0 /P d+ dWP OH/p H/P OH�O/P7- 10,0' RECEIVING PIT o 0)Cy) IN) � pl I \ rn�Nrns 1 \ ,p 1 4 3- S 'X (n r — NV5�2_2 Fee �FBoc- r -�"- —� 50 �-R —— — — — — 1— T �OC =F0 woe Foc Foc Foc— FOCI fac— FBC' Foci--'Foc7—Fac—, � — / _ FOC��T I-oG� �E' �- Fw� f - Ff�� Poc>— FOc T T T—T— T'—T—TTt T�- TT� _T T��T—T—T�-7—� r /I � 1�L li-TTT T —T,— 0)0 o0\ i■■ ■■■■■■■■■■■_-WEG■ ■ ■ r—♦iaaart s as 14 . a sai f �■ ■tr■i r ■tea~�rrr■ r + ------- ------ w------------- ■ ■ NV ~ \ \ \\ PROP. WATTLE \ ) \ > / 1 20'x10' LAUNCHING PIT\ t / -■■ OG STD. 457 C- - /-/�- �� III I■I o 1 \ 11 n tiocoPROP EROSION CONTROL MATTING.4 (3)PROP EROSION CONTROL MATTING o o wo� SEE DETAIL 5 SHEET 04D-08 vI SEE DETAIL 5 SHEET 04D-08 IZ (NCDOT STANDARD 1631.01) (NCDOT STANDARD 1631.01) 05F-061 bII \002 P-0P�. wALI 1I \ II \\\ \ \\ \ \\ \\ \\\ \\ PROP. 47 LF SILT FENCE 'Co U )/041) \ , DU NE COG STD. 430 h � ALDwFE SL DDt PROP. WATTLE Q754\ - - - - - - - - \LV9a,p(P-05805C-06) 2`PG Q \ \ \ M01ChARD,�LC - _ — — _ _ / / � // // �/ // / //// // \ �y// I I I \ \ \\ \ \ � / COG STD. 457, TYPICAL 1 \ \\ \ RC REID 82926 III(A(l�( \ 1 I I \ \ \ \ 1 / I I 1 I \ \ — o — — — — — _ / \ DEED BOOK 2438, PAGE 1149 0 o PLAT BOOK138, PAGE68 PROP. TEMP STONE DITCH PROP. 438 LF TREE PROTECTION/ CONSTRUCTION 0002 (P-05805F-06) CHECK DAM FENCE COG STD. 432 I DUAND WIFE LL \ — \ CAROL 5. WALL PROP. 104 LF SILT FENCE RC REID75472 COG STD. 430 I DB 2242, PG 407 1 I 1 ► / \ I � I / \ I JIMMY J. WHITERKER / JIMMY J. WHITERKER AND WIFE AND WIFE I 5JA GLOBAL I NELMA J. WHITERKER l NELMA J. WHITERKER I ADVISORS, INC I 5820 STARMOUNT RD 5820 STARMOUNT RD O 5840 STARMOUNT RD \ / RC REID 75486 DEED RC REID 75485 RC REID 75486 D BOOK 1664, PAGE DEED BOOK 1664, PAGE \ I DEED BOO1496 K 6786, PAGE I ' PLAT BOOK 59, PAGE 37 \ I PLAT BOOK 59, PAGE 37 I PLAT BOOKK 5 59, PAGE 37 / I Q \ \� PROP. TEMP STONE CD DITCH CHECK DAM I /� / I PROP. WATTLE \ \ I / I \ \ \\ \ \\ \ \\\ \ \ °' ►\ \ 1\ \ \ 1I \ I I ( \ \ I I \ \ \\ \� \s ` so7 _ - \ \ \ \\ \ \ o .� COG STD. 432 \ `) \ \ \ I \ I \ COG STD. 457, TYPICAL \ I I ( \ \ \ �\ 6 10 \e - - _ _ _ _ _ - \ l ) \ \ \\ \ \ + I \ I rn \T s .9\\ -- _ p9 / / / / \ i p p0 a" \ \ \ , \ \ ,� / % `- \ \ ` I I I , I r.— \ I t \ \ \ �, rn �', o "'P \ \\ \\ _ 6 n \ �I hl I rn \\\ \\ _ ~- 9 LO 6� \ I iW W W �� 1 ti I I N N N Z,� N 6`N N N� N \ _ / / O/ ?; 1 / / d I �1\ II o ' a'WI rn� w �wIM �`" n w ro o IIM I5 I 6\CD GO v rn s v \ \\ \\ i� ---'� <o O p� o� `\r\/^\ Q I i I \ \ \--- �� �---- — — Q \\N \ D ,� �, W / / / / l Ill Iw I\\ \ / �) / / ) I \ \�� �� ►- S i i i i h S II \ \ I t \ _ % — 1 �� I II / I" \ 1 \\ I�w�l \ / / Il l/I/ I'QI \\\ / _-//�_ l / / / / �' -- -- _ / �- J -- ern,\ \C0 Ile ■■ ■�■■■■■■�t \.ate■ ■'G■ RI•■■■■ a■■■■■_L■...- a "40 saw■au a■ 'E■■'Ea 406 60 / / + FM— xElm— — _ \ \ \ \ \ — \` \ x—x—xx z L ♦ \ - — _ 1 \ \ x x x x x 1 \ _ \ x x INS {I\ O/ OH 9CIE- J \ \ \ \ \\ \ \ \ l\ \ l \ ell \\ \\\ \\ \\ \ \\ \\\\ \\\\ \\ I \ \\\ PROP. 239 LF SILT FENCE \ \ COG STD. 430 \ \ \ \ I \ IOPEN CUT AND REPAIR GRAVEL DRIVE (6.38 TON) I I I HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 OH/P OH/P OH/P OH/P 1 OH OH/P OH/P OH/P /P OH/P OH `�.OH/P OH/P OH/P OH/P OH/P OH/P OFi/P OH% OH/P OH/r �� OH/P��-SN/� OH� �iBH/P—M1\/P� 011/ OH/P OH/ ♦ \ \ \ \ \ \ N e O o o '„`r`� ■ ■ rn \rn \ ■ a \ ♦ \ \ \ 6� N N 1 6` 6� rn a� .. of LL1 ♦ \ \ \ S sc� n \ \ \ I \ \ ' \ N\ 1 o�■■ifi■■.o■■■■�■■■� �■■■■■g■■■p■gO ■■sue■ ♦ 1z \ \ \MEN T %" / l / l // / / /� 1 1 // 2 \ no PROP EROSION CONTROL MATTING \ \ \ \ \ \ \ \ \. I / / / / / \ I 0 \\ \ SEE DETAIL 5 SHEET 04D-08 `\ \ \ \ \ \ \ \ \ \ \ \ \, �- t� I 1 I // / / / / / / / / / / / I I I- \ (NCDOT STANDARD 1631.01) \ \ \ \ \ •l / / / / / \ \ \ \ \ \ \ \ \ \ \ \ SENSITIVE CONSTRUCTION AREA PROP. 95 LF SILT FENCE \ \ \ \ \ \ \ WITHIN LOD OF DRAINAGE AREA COG STD. 430 r \� \ \ \ _ \ \ \ \ \ \ \ SEE SHEET OOG-01 FOR SPECIFIC \ CONSTRUCTION SEQUENCE OPEN CUT AND REPAIR ♦♦♦ ..���• GRAVEL DRIVE (3.78 TON) '•••����� ��.���•••• PROP. 438 LF TREE PROTECTION/ CONSTRUCTION ��� ♦�� FENCE REVISIONS TYPE ROADWAY SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK CONTRACT ICONTRACTORI AS -BUILT IAUTH. DATEI WATER AND SEWER PERMITS 2022-013C JOB NO. P- 05805C DESIGNED 11/2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED GENERAL NOTES: 1. PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. LOCATIONS OF EROSION AND SEDIMENT CONTROLS MAY NEED TO BE ADJUSTED BASED ON FIELD CONDITIONS. 3. CONTRACTOR SHALL NOT PERFORM ANY WORK WITHIN WETLAND AND STREAM AREAS UNTIL 401/404 PERMITS ARE RECEIVED. 4. NOT ALL KEYED NOTES ARE USED ON EACH SHEET KEY NOTES: O20'x10' LAUNCHING PIT, TYPICAL. O10'x10' RECEIVING PIT, TYPICAL. OPROVIDE BERM WITH SILT FENCE ON OUTER EDGES AROUND BORE/RECEIVING PITS TO REDUCE INFLOW. 4O PITS SHALL BE DEWATERED USING SILT BAGS BEFORE WATER IS REINTRODUCED TO THE CREEK. EROSION CONTROL NOTES: 1. CONSTRUCTION SHALL BE COMPLETED DURING TIME OF LOW FLOW. 2. WEATHER FORECAST SHOULD SHOW NO PRECIPITATION FOR 48 HOURS AFTER COMPLETION OF STREAM CROSSING. 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE STABILIZED AS WORK IS FINISHED. 4. LIMITS OF DISTURBANCE WITHIN BUFFER SHALL BE LESS THAN 40' IN WIDTH. CONTRACT SHEET 31 of 43 SENSITIVE INFORMATION Not to be copied or disfitbuted without the express written permission of the City of Greensboro. 8� CWNorth Carolina� City of Gree ro er rounc Locates I o uests COG Water e rce 73-2033 GDOT Traf is _ - - 73-2606 COG/GUilf rd Co. Telecom - 73-2084 COG Water Supply -- - - - - 73-5855 Tanks/Tr atment Plants �'I GDOT Storm Water _ _ _ _ 7,/t,73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted Ihestyle were not surveyed, they were compiled by photogrammetitc methods, available on the Geographic Informatlon Sydem (GM software used by the city of Greensboro. 40 0 40 HORIZONTAL SCALE IN FEET LEGEND: 50' BUFFER STREAM EROSION CONTROL MATTING DRAINAGE AREAS SILT FENCE TREE PROTECTION a 0 — LOD - LIMITS OF DISTURBANCE —TDB TEMPPORARY CLEAN WATER DIVERSION SILT FENCE ROCK OUTLET WATTLE TEMP STONE DITCH CHECK DAM CONSTRUCTION ENTRANCE INLET PROTECTION i K I I_ CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension 16" FORCE MAIN JULIAN AIRPORT ROAD EROSION CONTROL PLAN STA 390+00 TO STA 410+00 `.,•�N CARO Ice 04 0F�S51a Z ¢ EA Z 18 INeE$�*�' %Lf 04E-08 SHEET NO. 31 of 43 \ \ \ \ \ lull. ^.P��(( \ ��✓\ ���` Sri\ � �i/�� ♦�.���� '�-- /J.• //� \ \ \ \ \\ \ \\ \\\ / �♦ // �_� ��. �� \ \ /1$9 58 ♦/C •k�••• — \ \ \ \ \ \ \� \ \ \ \ \ — — ♦ / / �� I \ \ \ \ \ STREAM / / 11 \��♦♦ x� — — \ \ \ \ \ \\ \ ♦ / ♦ J 0.9 . 153 ♦♦ CONSTRUCTION ENTRANCE _ _590 \ \ \ \ \ \ \ \ ♦ _ _ _ \�\ \ I\\� ` \�--� --// �-- \I ��� ZSg� Ate/ � ♦♦ � � �, � SEE CONCENTRATED FLOW 1 \ \ \ \ \ \ \ \ \ \ - - - - 10, + �;� ♦♦4 CROSSING CONSTRUCTION- \ \ \ \ \ \ �o� /�/ /�� � j / :♦ ♦♦ ` ♦♦ SEQUENCE ON SHEET OOG-01 \. \ \ \ \ \\ \\\ \ \\ N_ i LUTHER GENE 6,G�8 \ \I \ \ �� / , ��x // �� \ �s ♦ 0095E (P 05805C O6) \ \\ \ \ \ \ \ \ \ • AND WIFE \\ \ \ \ \ f / / /+ J • ►.p -tie 0005 (P-05805E-07) \ \ \ \ \ \ \ \ EILEEN MARTIN CO L' \ \ / // / 0.0 AC _ 0001 (P-05805E-06) I i \ \ \ • • \ / \ ! MONARD LLC \ \ \ 1 STARMOUNT-RD — \ / 1 4 � � ■ RC REID 8 640 \ 1 \\ �S91� 3 / • ••••/ \ �� — �� ` � RC REID 82926 DEED BOOK 1378 P46 311 \ \` 9� / •♦♦ \� �\ \ DEED BOOK 24�8�PAGE 1149 \ • PLAT BOOK 130, PA(E�38- \ \ \ \ / j♦♦ / /) \ \ ) I ems j PLAT BOOK 138, PAGE 68 \\ \ \ ■ / L, \ �`` I /♦♦ /�� < \)})I i \ \ \ SEE CONCENTRATED FLOW \ / I /�♦♦ �� / \\ �� i / \ �)� SEE CONCENTRATED FLOW CROSSING CONSTRUCTION ■ PROP. TEMP STONE DITCH I L _ /♦♦ / '� + \ \\' \ I ���/ �, CROSSING CONSTRUCTION ♦ SEQUENCE ON SHEET OOG-01 CHECK DAM V \ \ �' �'I` �/ �QO� \ ���` BOO \ SEQUENCE ON SHEET OOG-01 i COG STD. 432, TYPICAL • �. I /I / /♦ / 6' 582'3 g' \/ \' \ I �� i \ , \ \ \ �� 100-YR FLOOD ZONE i PROP. WATTLE 0.12♦ Z`p- 1 - ♦ ■ / /♦ PDX COG STD. 457, TYPICALPROP. 86 LF SILT FENCE S9s_'.\ ` -\ \ \ ` \ - - s' to I US \ ,c 1 �� / COG STD. 430 _ \ M sr7 \\ \J y - TEMPORARY CLEANWATER I \ `A \ 1 I I I I / /♦ I I \ \ O ♦w 8x�o \O�\ ` - DIVERSION SEE DETAIL 1, ♦♦ I 1 I I I �►� \ \ \ 1.01 AC DIVERSION S Seg- -- \\ \ SHEET 04D-06 ♦♦♦ / Z o lit I / G i l \ PEP�pNEPM \\ \ \ �� ,, L' `\ j ss , \ \ ♦♦� l�o°s� l l I / /• I l : 1 / I \ s s' < �\ . o l �\f<<g�� l / l / /� �, \ \ \ J \ ��''►� A, \ \ ♦♦ ♦ SEE CONCENTRATED + / / / \� ��'%�,o°� / / /• I 1 i °i \ \ B� _ �Se� \ \ \ \♦♦ FLOW CROSSINGCD PROP. 130 LF SILT FENCE � \ <O \ • �'• �� — � \ \ � \ \ . \ � ~ ♦♦� � \ N \ I / I / /♦ I \ COG STD. 430 O �/ 584- - ,�6 •�}l� D \ 9 \ CONSTRUCTION �i- I I // / /• / S \ i '� \ ° Lp•••••\� \ -I. ` S O \) \ \ ^� - \ SEQUENCE ON Q 1.30 AC • \ \ SHEET OOG-01 -/ / / �� \/ I •� 3- 1 PROP. SILT FENCE STONE OUTLET F 42 • •�: OD \ \ ` �i / \ \ \ •a 5g 0.14 • J I// / • ° \ \ 1 COG STD. 430, TYPICAL PAD O ® \ ��`- � .Se �•••.■,� � p `gyp � • \ \ � \ \ � _ , ` = _ see•\\` ••`•■1a \ \ \��--- 44 ■ _ 595 \ \ PROP. 66 LF SILT FENCE -42�-+DD _ - ■� � -596- — \ \ COG STD. 430 �` �,,� .'� Q � � \ \ \ F5p / \ \ LOD � \ \ \ \ \ PROP. 67 LF TREE PROTECTION/ CONSTRUCTION i ` '■-�_�` LOD \�^ M - F\IUI-- - \22gQ /ft%w, —n597- FENCES- \ PROP. 146 LF SILT FENCE ST \ \ \ SENSITIVE CONSTRUCTION AREA COG STD. 430 �` LOD A 4)�+0�\ \ WITHIN LOD OF DRAINAGE AREA, SEE �.\ / I �� _-___\�• — — SHEET OOG-01 FOR SPECIFIC CONSTRUCTION SEQUENCE i \�`� LOBe� i --- \--- ) L_OD --- �\ PROP. 186 LF SILT FENCEJ� COG STD. 430 LU PROP. 366 LF SILT FENCE U PROP. TEMP STONE DITCH CHECK DAM I— � � COG STD. 430 COG STD. 432, TYPICAL STREAM BUFFER GENERAL NOTES: 1. PREPARED BY SPATIAL DATA CONSULTANTS, INC. AND BRADY SURVEYING COMPANY, P.A. DURING THE WINTER OF 2015. 2. LOCATIONS OF EROSION AND SEDIMENT CONTROLS MAY NEED TO BE ADJUSTED BASED ON FIELD CONDITIONS. 3. CONTRACTOR SHALL NOT PERFORM ANY WORK WITHIN WETLAND AND STREAM AREAS UNTIL 401/404 PERMITS ARE RECEIVED. 4. NOT ALL KEYED NOTES ARE USED ON EACH SHEET KEY NOTES: 0 20'x10' LAUNCHING PIT, TYPICAL. O10'x10' RECEIVING PIT, TYPICAL. OPROVIDE BERM WITH SILT FENCE ON OUTER EDGES AROUND BORE/RECEIVING PITS TO REDUCE INFLOW. OPITS SHALL BE DEWATERED USING SILT BAGS BEFORE WATER IS REINTRODUCED TO THE CREEK. EROSION CONTROL NOTES: 1. CONSTRUCTION SHALL BE COMPLETED DURING TIME OF LOW FLOW. 2. WEATHER FORECAST SHOULD SHOW NO PRECIPITATION FOR 48 HOURS AFTER COMPLETION OF STREAM CROSSING. 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE STABILIZED AS WORK IS FINISHED. 4. LIMITS OF DISTURBANCE WITHIN BUFFER SHALL BE LESS THAN 40' IN WIDTH. LEGEND: 50' BUFFER STREAM i ■ _ - _ - / / / / • EROSION CONTROL MATTING 0095E (P-05805C-06) T — _ _ _ / / ■ ■ ■ ■ ■ ■ ■i ■ 0005 (P-05805E-07) ■ � � / ♦ / ■ � DRAINAGE AREAS 0001 (P-05805F-06) SEE CONCENTRATED FLOW — — / i / / / / / !� i■■■■■■r CD MONARD LLC CROSSING CONSTRUCTION ■ / / / RC REID 82926 _T--/�// /� 'I� / • + DEED BOOK 2438, PAGE 1149 SEQUENCE ON SHEET OOG-01 SILT FENCE • N PLAT BOOK 138, PAGE 68 ■ / / , ' • , ■ ■ — _ — — _ / / / / A. .0 .0 TREE PROTECTION LOD — LIMITS OF DISTURBANCE Q ■ / / / / •/ TEMOPORARY CLEAN (� _\ \\\ : / r 1� �� / // J �_ -- —_�� � � �i = yTDy WATER DIVERSION SEE CONCENTRATED FLOW -,r - � / / / • � SILT FENCE ROCK OUTLET —.... ------- _CROSSINGCONSTRUCTION // // / • 1z WATTLE \ \ \ v pc�+- ■- - - - J i / _ - - - - - i / 1 \ SEQUENCE ON SHEET OOG-01 Be TEMPORARY CLEANWATER m a �\pp.\ \ / / / / - - J I I \ - ■ - DIVERSION SEE DETAIL 1, / / i TEMP STONE DITCH CHECK DAM i'�■ �� y ��_�- / /�� /-- - // / / 587-- i�� �SHEET04D-06 _ f \\F9- ,5g '595�Q,��L�� ��LO -.� \ (/ / I/ I ^ \ \ ` — _ — V 586 -- i / ,�S9i LC; CONSTRUCTION ENTRANCE �Se9 � _ --- --// / �-425+ -` - ■■L■O.DQ, ��w�w LOD - _ /• _� ti' / � \ � ®S��C#/r•.�.•■�q �/ LO -L / /' f � 585- ct i PI 4 432 J -" g90 J FM N -r FM 4��9 p6- - . �' f+fs,�, LOD ■ - / / LOD j 502 RM I --- _ ` l 587 \ - ■5a8 ,, FIVE }� �5 427+00 ■ / a1 - '** - �584 i _ LOD E 0 / M 31" / _ 015 L-09 ■ ■ LOD _ ■ _ - W I - ^LbD��� - -,7i - - - g0�' i 6 ■■f'p�l■f■.. LO S-PG iTi L / • / _ / OD - �� �g ii�•■■■SET*OD `L� - G i _tp f`� FM 429+00 - x \� LOD LODOr - '� �� FM - � FM / / / / • LOD Cn FM LOD PROP. 366 LF SILT FENCE `� \ \\\ _ LOD - '- - --- COG STD. 430 LOD 0 i \ - ■ PROP. TEMP STONE DITCH CHECK DAM COG STD. 432, TYPICAL - PROP. SILT FENCE STONE OUTLET COG STD. 430, TYPICAL HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 ■ , i� — _ \ — — — — PROP. 381 LF SILT FENCE COG STD. 430 STREAM BUFFER REVISIONS TYPE ROADWAY SEWER REVISED PER NCDEQ COMMENTS WATER 100% SUBMITTAL SIDEWALK PROP. 354 LF SILT FENCE COG STD. 430 100-YR FLOOD ZONE CONTRACT ICONTRACTORI AS -BUILT IAUTH. DATEI WATER AND SEWER PERMITS 2022-013C JOB NO. P- 05805C DESIGNED 11/2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED CONTRACT SHEET 32 OF 43 SENSITIVE INFORMATION Not to be copied or disMbuted without the express written permission of the City of Greensboro. ortft MN !v bna ■ City of Gree ro er rounc Locates I equesft COG Water e rce 73-2033 GDOT Traf is _ - - 73-2606 COG/Guilf rd Co. Telecom - 73-2084 COG Watpr Supply -- - - - - 73-5855 Tanks/Tr atment Plants /I GDOT Storm Water _ _ _ _ 7,/t,73-2569 NPDES General Permit Applies DISTURBED AREA = 14.76 AC GIS DISCLAIMER Objects on this map shown with a dotted Ihestyle were not surveyed, they were compiled by photogrammetric methods, available on the Geographic Informatlon System (GIST software used by the City of Greensboro. 40 0 40 80 HORIZONTAL SCALE IN FEET I K CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension 16" FORCE MAIN JULIAN AIRPORT ROAD EROSION CONTROL PLAN STA 410+00 TO STA 430+00 " CA -04 oFess/p Z ¢ ►% EA Z D � /,ADk �'�,� I% G I NE�' NE-09 SHEET NO. 32 OF 43 / � � v•�. � \ \ \ \ f \ \ SANDI�C�LIFT STATION \ (NOT IN CON �••• \ �E _ c�rr f' f-NA1f' rAITrIATrr'% M /l\A/ O co d'I �r w -7"�D UJ Lam— _ U ,�- ~ PROP. TEMP STONE DITCH Q _� CHECK DAM COG STD. 432, TYPICAL \ \ PROP. 281 LF SILT FENCE \ COG STD. 430 ► ► GENERAL NOTES: CONTRACT SHEET \ i I \ i \ I ►� I i / VALVE \L J \ \ I ' I ( \ \ 1. PREPARED BY SPATIAL DATA CONSULTANTS, 33 OF 43 INC. AND BRADY SURVEYING ✓ ULT \ \ I II I� 1 \\ \ I DURING THE WINTER OF 2015.COMPANY, P.A. \ //I ► I \\ �/ \\ I 2. LOCATIONS OF EROSION AND SEDIMENT SENSITIVE INFORMATION \ \ CONTROLS MAY NEED TO BE ADJUSTED Not to be copied or ,.r• \\ s\ \\ \ / `� distributed without the o I �� BASED ON FIELD CONDITIONS. \\WET WELL \ I \ I ' \\\ \ \ \ II / 3. CONTRACTOR SHALL NOT PERFORM ANY express written permission of • •v \ I \ \ I \ WORK WITHIN WETLAND AND STREAM AREAS the City of Greensboro. — _ _ �_ \ I ► \ \ � � � \ I \ UNTIL 401/404 PERMITS ARE RECEIVED. 4. NOT ALL KEYED NOTES ARE USED ON EACH p,15 AC c� �r I ► \ I I SHEET 0 � ► � � � \ \ KEY NOTES: 14 I ► \ \ / \� \ \ \ I O 20'x10' LAUNCHING PIT, TYPICAL. 10'x10' RECEIVING PIT, TYPICAL. I / ► \ \\ \� \ \� \\ I\ \\ \ PROVIDE BERM WITH SILT FENCE ON OUTER EDGES AROUND BORE/RECEIVING PITS TO I I REDUCE INFLOW. o ' PROP. 396 LF SILT FENCE \I \\ \ I \\ \� \ — \\ 4 PITS SHALL BE DEWATERED USING SILT city Lo atesee6 r er ec rounts d COG STD. 430 I \ I \ \ \ \ O BAGS BEFORE WATER IS REINTRODUCED TO \ \ THE CREEK. COG Water e rce 73-2033 \ \ _ GDOT Traf is 73-2606 COG/Guilf rd Co. Telecom — 73-2084 PROP.351 LF TREE PROTECTION/ CONSTRUCTION \ \ COG Water Supply_ — — — —— 73-5855 84 — / I FENCE \ \ EROSION CONTROL NOTES: Tanks/Tr atment Plants 10' _ _' Fly 73-2569 — ✓ \� _ — — 1. CONSTRUCTION SHALL BE COMPLETED GDOT Storm a\ter _ _ _ 3 1r 3 I \ 100-YR FLOOD ZONE \ \� DURING TIME OF LOW FLOW. 9 38. / �► I \ ` \ \ 2. WEATHER FORECAST SHOULD SHOW NO NPDES PRECIPITATION FOR 48 HOURS AFTER — —\\ \ \\ COMPLETION OF STREAM CROSSING. General Perm} s —581 \ i _ \ // , / N l \ 3. ALL AREAS WITHIN RIPRAP BUFFER SHALL BE Applies ■ 0). J \ / I I STABILIZED AS WORK IS FINISHED. ~ �r / ► I (\� �.- _ — / / 4. LIMITS OF DISTURBANCE WITHIN BUFFER \ 11 /iu ► < i / SHALL BE LESS THAN 40' IN WIDTH. DISTURBED AREA = / 14.76 AC 010. GIS DISCLAIMER Objects on this map shown with a I ► \ — — — — _ \ / — \ — dotted lhestyle were not surveyed, / / ► -� 1 were compiled avallable on the Q�raphlc l 41 ►') I �� �--_�---� �� i� LEGEND: theyby — , photoArammetilc methods, icc\ / wI \ / / 50' BUFFER STREAM Informatlon System (GIS) software used by the City of Greerlsboro. EROSION CONTROL MATTING DRAINAGE AREAS SILT FENCE 40 0 40 80 TREE PROTECTION — — SOD — LIMITS OF DISTURBANCE HORIZONTAL SCALE IN FEET 10 0 10 20 —TD— TEMOPORARY CLEAN WATER DIVERSION VERTICAL SCALE IN FEET SILT FENCE ROCK OUTLET WATTLE TEMP STONE DITCH CHECK DAM CONSTRUCTION ENTRANCE IIm ,-� '•� M. YA' HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS REVISED PER NCDEQ COMMENTS 100% SUBMITTAL TYPE ROADWAY SEWER WATER SIDS CONTRACT ICONTRACTORI AS -BUILT IAUTH. DATEIWATER AND SEWER PERMITS 2022-013C JOB NO. P- 05805C DESIGNED 11/2022 BY MAS CONST. SURVEY BY CHECKED BY SCALE: AS NOTED CITY OF GREENSBORO WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension 16" FORCE MAIN JULIAN AIRPORT ROAD EROSION CONTROL PLAN STA 430+00 TO STA 439+00 04E-10 SHEET NO. 33 OF 43 SERIES H 1 C ACCESS DOOR STANDARD FEATURES: •H20 LOAD RATING (SEE NOTES) •EXTRUDED ALUMINUM CHANNEL FRAME • SINGLE LEAF CONSTRUCTION • AUTO -LOCK T-316 STAINLESS STEEL HOLD OPEN ARM WITH RELEASE HANDLE • T-316 STAINLESS STEEL HINGES AND ATTACHING HARDWARE •T-316 STAINLESS STEEL SLAM LOCK WITH REMOVABLE KEY • STAINLESS STEEL COMPRESSION SPRING ASSIST • RECESSED LIFTING HANDLE • LIFETIME GUARANTEE SLAM LOCK LIFTING HANDLE 0 A OPENING A DIM. + 11 " (279 mm) OVERALL A OPENING (COVER SHOWN IN OPEN POSITION) 4 1 /2" �(108 mm 1 1 /2" (38 1 SECTION ALUM. COUPLING www.HaIIidayProducts.com Phone 800-298-1027 Fax 407-298-4534 HALLIDAY PRODUCTS Sales@HallidayProducts.com STANDARD SIZES QTY. MODEL NO A DIM. INCHES (mm) C DIM. INCHES (mm) UNIT WT. I (kg.) H1C2424 24 (610) 24 (610) 85 (39) H1C2430 24 (610) 30 (762) 100 (45) H1C2436 24 (610) 36 (914) 115 (52) H1C2442 24 (610) 42 (1067) 130 (59) H1C3030 30 (762) 30 (762) 108 (49) H1C3036 30 (762) 36 (914) 124 (56) H1C3042 30 (762) 42 (1067) 140 (64) H1C3048 30 (762) 48 (1219) 157 (71) H1C3636 36 (914) 36 (914) 134 (61) H1C3642 36 (914) 42 (1067) 151 (68) H1C3648 36 (914) 48 (1219) 166 (75) NOTES: 1) SUITABLE FOR USE IN OFF STREET LOCATION WHERE NOT SUBJECTED TO HIGH DENSITY TRAFFIC. 2) PROVIDE A FULL BED OF CLASS "A" CONCRETE UNDER FRAME AND SUPPORT ANGLES. S. STL. SPRING 1 /4" (7 mm) THICK DIAMOND PATTERN ALUMINUM COVER PLATE T-316 STAINLESS STEEL HINGES WITH TAMPER PROOF FASTENERS IMER REQUIRED ARV MANHOLE HATCH GRADE SECTION _FLOWABLE I I I I I SEWER II T—MAIN I I I� I IIII I I DIGABL E FL OWABL E FILL @ 200 PSI OR O a a CLASS B CONCRETE, `I as a T 4a III I a IIII _ I IIII i j IIII I I I I I I I TRENCH WIDTH PLAN C/ T Y O F G R E E N S B O R O ANTI -SEEP PIPE COLLAR STD. NO. REV. 06-15 FOR SEWER LINES 219 L OCKIP RINGS 5/8 - J— T ti h PLAN 7/8" M 1/4 „ ELEVA TION COPOL YMER POL YPROPYL PLASTIC ° = • - ° • ' - -A. #3 DEFORMED Ar STEEL ROD --°- a--: 0 a _ _ • - v S:::: TOP DEPTH INTO CONCRETE SURFACE I 3 1/2" w STOP 1 1/4" 1/4" M T h SIDE EL EVA TION COMPOSITE SECTION A —A C/ T Y O F G R E E N S B O R O STD. NO. REV. t STANDARD MANHOLE STEP FOR W PRECAST CONCRETE MANHOLE 2066 2 ' -0 " OR TO L IP OF GUTTER, CURB, PA VEMENT PA TCH OR EDGE OF PAVEMENT WITHIN 5 ' -0 " OF SECOND SAW CUT NOTE.' 1) FULL LANE RESURFACING AND/OR MILLING MAY BE REQUIRED 2) 3'-0 " MAY BE REQUIRED AT THE DISCRETION OF THE A -A = INITIAL CUT CITY ENGINEER OR DESIGNEE. B-B = SECOND SAW CUT C 'A16 NMI I ••••••••��••••• - COMPACTION REQUIRED AFTER TRENCH FILL 6 BASE COURSE PLACED AND COMPACTED (TYP. ) COMPACTED 1 BACKFILL IS" NOMINAL 18" WIDTH INSTALLATION NOTES.' A B *2'-0"� + + + _ ++ + EX. BASE _ ++++ COURSE + 12" (TYP. ) COMPACTION REOUIRED ON SUBGRADE (TYPICAL) I19.00 INSTALLED IN TWO LIFTS OF 2-1/2". MATERIAL DEPTHS SHOULD EQUAL EXISTING, PLUS 1', OR MINIMUMS SHOWN (WHICH EVER IS GREATER) . FILL MATERIAL COMPACTED TO 95% STANDARD PROCTOR LIFTS NOT TO EXCEED 8 INCHES. PROVIDE TACK COAT TO ALL VERTICAL PAVEMENT SURFACES. SECOND PA VEMENT REMOVAL L INE B-B TO BE SAW CUT ONL Y. MAY VARY BASED ON FIELD CONDITIONS AT DISCRETION OF FIELD INSPECTOR. ADDITIONAL NOTES.' 1. TEMPORARY STEEL PLATES ARE ALLOWED TO BE INSTALLED OVER A TRENCH OPENING. 2. EDGES OF STEEL PL A TE MUST BE MILL ED TO ALL OW THE PLA TE TO SI T FL USH WI TH THE ADJACENT ASPHALT SURFACE OR ASPHALT COLD PATCH MATERIAL MUST BE PLACED AT THE EDGES OF THE PL ATE. 3. ANCHORS ARE REOUIRED TO TEMPORARIL Y FASTEN THE STEEL PLATE TO THE ASPHAL T TO PREVENT SLIDING OF THE PLATE. 4. STEEL PLATE SHALL BE MAINTAINED UNTIL THE AREA IS READY FOR A PERMANENT ASPHALT REPAIR. 5. STEEL PLATES ARE NOT TO BE USED DURING THE WINTER MONTHS. 6. ADVANCE WARNING SIGNS INDICA TING "BUMP AHEAD " OR "UNEVEN PA VEMENT AHEAD " SHAL L BE UTIL IZED WHEN S TEEL PL A TES ARE USED. C/ T Y O F G R E E N S B O R O PAVEMENT REPAIR FOR PIPE/UTILITY STD- NO. REV. PLACED UNDER EXISTING PAVEMENT (ROADWAY) 423 03-103-15 03-18 5 06-15 u 0 u 11 BC t 8" MIN. 1-1/4 BC u u �. 2000 PSI "..-.-: •�•-.: DENSEL Y ti to s" aY-'' ¢9 CONCRETE...- - '• ° :: NT COMPACTED BACKFILL h K :a: .. : - ti • NT e.. .4 .e:•:a•a-: II .III II A- BCI— Bc I — CONCRETE ARCH LIGHTLY �g COMPACTED h BACKFILL GRANULAR FOUNDATION DEPTH OF BEDDING MA TERIAL BEL OW PIPE D d (MIN. ) 27" 9 SMALLER 3" 30" TO 60" 4" 55" 6 LARGER 6" GRANULAR FOUNDATION CLASS D FLAT SUBGRADE LEGEND BC _ OUTSIDE DIAMETER H BACKFILL COVER ABOVE TOP OF PIPE D = INSIDE DIAMETER d = DEPTH OF BEDDING MA TERIAL BELOW PIPE NOTE.' USE 467M OR A. R. E. A. (AMERICAN RAIL WA Y ENGINEERING N ASSOCIATION) #4 STONE FOR 21 " AND LARGER PIPE. C/ T Y O F G R E E N S B O R O STD. NO. REV. t STANDARD TRENCH BEDDINGS FOR 03-97 w CIRCULAR PIPE 207 i ••••••••••• ••••••••••••• COMPACTION REOUIRED ON SUBGRADE REMOVE 6 REPLACE EX. ASPHAL T TO STR1 W/ 1.5" OF S9.5B ASP ASPHAL T DRI VENA YS COMPACTION REQUIRED ON SUBGRADE C/ T Y O F G R E E N S B O R O PAVEMENT REPAIR FOR PIPE/UTILITY PLACED STD. NO. REV. 08-02 03-15 UNDER EXISTING PAVEMENT (ASPHALT DRIVEWAYS) 14P3-A 03-03 1 09-03 NOTES.' CONCRETE SHALL BE CLASS AA, 4000 PSI AS PER ASTM C-478. STEEL REINFORCING SHALL MEET ASTM C-185 (4" DIA) OR ASTM C-478 (5" DIA) . MANHOLES OVER 3'-6" IN DEPTH SHALL BE PROVIDED WITH STEPS 16" ON CENTERS. STEPS SHALL BE IN ACCORDANCE WITH COG STD. #206. ON NEW INSTALLATION A MAXIMUM OF (2) GRADE RINGS CAN BE USED. FOR C-900 DR-18 PVC FORCE MAINS USE ROCKWELL SERVICE SADDLE 323, FORD, MUELLER, OR EQUAL. ALL PIPE TO BE MINIMUM 2" 316 STAINLESS STEEL ALLOY AND NIPPLES TO BE 2" 316 STAINLESS STEEL ALLOY. COG STD. #205 OR #205-A RING 6 COVER 00 -`' 5'-0" I.D. .; MIN 18" r ALIGN AIR RELEASE SHUT OFF VALVE ,. NITH EDGE OF FOR `- - •MANHOLE : EASY HAND ACCESS. J� ` --i _ O N _ 2 " (1/4 TURN) CRISPIN UNIVERSAL BALL VAL VE MODEL NO. U52OZ = = = = _ 45 -4 (OR EQUAL) 2 " AIR � `-_- _ RELEASE VALVE W/ 1/8 " ORIFICE. UNITHAS SCREWED INLET W/ BACKFL USH. NIPPLE - _-`=- - --9' 2 " WHEEL GA TE VA L VE - (TYP.) 2" 316 STAINLESS 22" STEEL ALLOY OFFSET 2 " CORP. STOP SEWER FORCE MAIN CC THREAD X FIP THREAD OUTLET 6 4 PLACE 12" OF #57 T N ' STONE UNDER BASE T . 6'-10" STD. #201 SEC TION THPL/ MA NHOL E C/ T Y O F G R E E N S B O R O AIR RELIEF VALVE WITH ASSEMBLY STD. NO. V. 211 03-03 03-22 06-07 AND MANHOLE FOR SANITARY SEWER LINES 03-08 F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 EXISTING RIGID REPLACEMENT TYPE PAVEMENT CONC. 3000 PSI a � 4 � p D 2 % CAREFULLY COMPACTED BACKFILL 12" 118" I DIA. 118" I 12_' MIN i MIN TRENCH PIPE NOTES: 1. EXISTING PAVEMENT SHALL BE CUT WITH A SAW. 2. ALL REPLACEMENT CONCRETE SHALL BE 2" THICKER THAN EXISTING CONCRETE. CONCRETE DRIVEWAY REPLACEMENT DETAIL NOT TO SCALE 24"x24"x6" CONC. PAD, TYP AT r- A ^" VALVE BC VALVE BOX AND COVER, TYPICAL 2500 PSI CONCRETE, MIN #4 BARS Al I ADnI IAIM UNIMPROVED AREA a 0 CONCRETE PAD a C/ CONCRETE COLLAR DETAIL 3 NOT TO SCALE TYPICAL SECTION CONCRETE CAP DETAIL NOT TO SCALE 12'-0" MAXIMUM BETWEEN SPACERS CARRIER PIPE CASING SPACERS SHALL BE SPACED A MAXIMUM OF 1'-6" FROM EACH SIDE OF JOINT CASING END PLUGS PAVEMENT CONCRETE CAP (3000 PSI) EE PIPE BEDDING ETAIL INSTALL THREE CASING SPACERS PER PIPE JOINT AS REQUIRED TO MEET MAXIMUM SPACING V-6" (MAX) 6" (MIN) PLUG STEEL CASING PIPE 1. CASING SHALL BE PLUGGED ON BOTH ENDS BEFORE BACKFILLING. PLUGS SHALL CONSIST OF MINIMUM OF 1 LINEAR FOOT OF LOW STRENGTH GROUT (1,500 PSI MIN). 2. PROVIDE SIX-1/2" DIAMETER WEEP HOLES ON DOWNSLOPE SIDE OF CASING. TYPICAL PIPE CROSSING NOT TO SCALE 4" ANSI E CLASS 12 4" WHEEL GATE VALV 24" MJ X 4" FLANGE ROTATED VERTICALLY AIR VALVE ASSEMBLY NOT TO SCALE STD WT STL PIPE SLEEVE, GALV AFTER FABRICATION ANNULAR SEAL PIPE THRU WALL OR FLOOR AS RECOMMENDED BY ANNULAR SEAL MFR INTERIOR, DRY OR TOP SIDE 1/4"x3" STEEL P L SEEP RING BURIED, WET OR BOTTOM SIDE " NGLE BODY COMBINATION VALVE CONNECT DRAIN HOSE TO DIRECT DISCHARGE TO VAULT FLOOR ORIFICE DATA ✓IETER WORKING PRESSURE /2" 20-150 PSIG INLET FLANGE DATA LANGE DIAMETER 11.00 in. -ANGE THICKNESS 1.00 in. T CIRCLE DIAMETER 9.50 in. 3ER OF BOLT HOLES 8 _T HOLE DIAMETER 0,88 in. ANNULAR LINK -SEAL PROVIDE SINGLE ROW OF SEALS FOR PIPES a o LESS THAN 16" DIA. PROVIDE DOUBLE ROW PIPE THRU v OF SEALS FOR PIPES 16" WALL OR FLOOR DIA AND LARGER. 0 AS RECOMMENDED o WALL SLEEVE BY ANNULAR SEAL o MANUFACTURER o o T/2 T ' 811 NOTE: TYPICAL PENETRATION OF BURIED DIP THROUGH CONCRETE PRECAST STRUCTURE UNLESS OTHERWISE INDICATED. PENETRATION THROUGH PRECAST CONCRETE DETAIL NOT TO SCALE r_­ o" 1 /2" SST ATE STRAF TYP 1 1/2" K 4" SST BC UTS (TYP) 1/2" THK. S "X 1/2" Tnr\. oo i (SHOE -BEND ENDS UP 1/2") CASING SECTION END ELEVATION NOTE: USE RACI PIDPE SPACERS, TYPE G, IN LIEU OF STEEL SPACERS WHERE INDICATED ON DRAWINGS. STEEL SPIDER DETAIL NOT TO SCALE PHASE IV SEWER FORCE MAIN EXTENSION GREENSBORO BUILDING A BETTER GREENSBORO PROJECT SIGN DETAIL NOT TO SCALE WHITE BACKGROUND COLOR LETTERS WHITE LETTERS COLOR BACKGROUND- PHONE NUMBER TO BE DETERMINED DURING SHOP DRAWING PROCESS - WHITE LETTERS 2 BULB TYPE POP RIVETS PER ANCHOR BARB - C S P A E I U W P T E R L 0 I N N E BEFORE DIGGING CALL qx-xxx-xxxx CITY OF GREENSBORO WATER RESOURCES DEPARTMENT NOTES 1. THE CONTRACTOR SHALL FURNISH, ERECT, AND MAINTAIN TWO 4' BY 4' PROJECT SIGNS AT LOCATIONS DESIGNATED BY THE ENGINEER. THE SIGNS SHALL BE CONSTRUCTED OF 3/4" PLYWOOD, CLEAR ON ONE SIDE, OR APPROVED EQUAL. THEY SHALL BE SUPPORTED BY TWO 4"x4" PRESSURE TREATED POSTS AND SUBSTANTIALLY BRACED. 2. THE SIGNS SHALL BE GIVEN ONE COAT OF A HIGH QUALITY PRIMER, AND TWO COATS WHITE HIGH GLOSS ENAMEL PAINT. LETTERING SHALL BE BLACK HIGH GLOSS ENAMEL WITH COLOR GRAPHIC WORK AS REQUIRED TO MATCH THE LOGOS. LETTERING SHALL BE AS INSTRUCTED AND OF THE GENERAL FORMAT SHOWN IN THIS SECTION. GENERALNOTES 1. MARKERS SHALL BE CARSONITE TYPE CUM-375 OR APPROVED EQUAL. MARKERS SHALL BE PIGMENTED WITH U.V. RESISTANT RESINS OR COATED WITH CLEAR UV RESISTANT COATING. 2. DECALS SHALL BE AS SHOWN AND PROVIDED ON U.V. RESISTANT BACKING WITH TEXT CONFORMING TO THE FEDERAL OFFICE OF PIPELINE SAFETY STANDARDS AND DENOTING THE STANDARD NO -DIG SYMBOL. 3. MARKERS SHALL EXTEND 4-FEET ABOVE GRADE. 4. MARKERS SHALL BE INSTALLED WITH MANUFACTURER'S APPROVED MARKER DRIVER. BURIED DEPTH SHALL BE 24" MINIMUM FOR LOOSE, SANDY, OR MARSHY SOILS AND 18" MINIMUM FOR HARD OR ROCKY SURFACES. 5. MARKERS SHALL BE INSTALLED AT LOCATIONS INDICATED ON THE DRAWINGS, OR AS DIRECTED BY THE OWNER. 6. WHERE COLOR IS INDICATED USE COLOR AS FOLLOWS: BLUE FOR WATER GREEN FOR SEWER I ITII ITV ftA A E:)IlCE) ME=A II HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, INC 28202-2075 704.338.6700 v dm r-E � C � H z > 40w rm��=-i -nn>rn .. Cn 0 Z 0_4 V r_ ZT �yaA cn rti a ZE v m W r �v X N X o= x� m-n *O a 2 1-4o G7 N xz in v W C 1-•I G7 m Q HEET 3 OF 3 1101.01 TWO-WAY UNDIVIDED [L-LINES END ROAD WOA1C vr� DZD-ze ,N•.:.� W2D-, ,a^Ra6" ROADWAYS INTERSECTING ALONG 2 WAY UNDIVIDED WORK ZONE WIK Rr)AWY wOHA ZONE LYJ 8"K24 TAD-, Y- tIN, MORN LI,ySI,UC 1 t pH HEW � 11M LfS } xzD_v 4B"%+N" RECOMMENDED POSTED $PEEP LI•IL MINIMUM (MPH)SIGR SPACING % OP 55 100D• Y-LINES GENERAL NOTES 1- USE FLUORESCENT ORANGE SHEETING (TYPE VII OR HIGHER) ON ALL ADVANCED WORK ZONE SIGNS. 2- DO NOT INSTALL ADVANCE WARNING SIGNS MORE THAN 3 DAYS PRIOR TO BEGINNING OF WORK, UNLESS COVEIIED. 3- SIGNS SHOWN ARE REQUIRED FOR WORK ZONES THAT WILL REMAIN IN EFFECT OVERNIGHT. FOR SHORT-TERM DAILY MAINTENANCE TYPE OPERATIONS, THIS SIGNING APPLICATION IS OPTIONAL; MAY USE ONLY APPLICABLE ROADWAY STANDARD DRAWINGS INSTEAD. HOWEVER, IF THIS SIGNING APPLICATION IS USED, SIGNS MAY BE PORTABLE MOUNTED. 4- ALL SIGN SPACING DIMENSIONS ARE APPROXIMATE, FIELD ADJUST AS NECESSARY OR AS DIRECTED. 5- USE 3LB STEEL U-CHANNEL POST OR 4" X 4" WOOD POST FOR ALL WORK ZONE SIGNS. 315 STEEL U•CHANNEL POSTS MUST MEET THE REQUIREMENTS OF STANDARD SPECIFICATION SECTION 1094-1($), MAY BE GALVANIZED STEEL, OR MAY BE PAINTED GREEN BY THE POST MANUFACTURES. SQUARE STEEL TUBING POSTS HAVING EQUIVALENT STRENGTH OF THE 3 LB STEEL U-CHANNEL POST ARE ALSO ACCEPTABLE FOR USE. ERECT SIGNS PER ROADWAY STANDARD DRAWING 1110.01- PAYMENT FOR WOOD POSTS, 31-13 STEEL U-CHANNEL AND SQUARE STEEL TUBING POSTS WITH SIGNS WILL BE MADE ACCORDING TO STANDARD SPECIFICATION "WORK PONE SIGNS" SECTION 1110. 5• WHEN NECESSARY, USE SPLICING IN ACCORDANCE WITH ROADWAY STANDARD DRAWING NO. 1110.01. 7- DO NOT BACK BRACE SIGN SUPPORTS. z o_N H } aQ z C=Fi v LLJEHZ C>c�,nz _ LU Z Q O �-4 U)oLOU 0 0 z H Q 1 EL LLI 0 0 W W W O N x= � W co 0 3 I"I F c O LL. W �x Z � F„1 N M to � 3 J W W LEGEND H STATIONARY SIGN SHEET 3 OF 3 ,*-DIRECTION OF TRAFFIC FLDW b Z ROADSIDE ACCESS POINT ACCESS THROUGH TEMPORARY BARRIER < DETAIL 9HOYN FOR LEFT 8I0E, BAYS PBINGIPLE APPLIES FOR REWrr SIDE ACCESSES F--' EN Z < Q }} r-C"mv �o~c�ca LESIST]HG � ry TRiICK � 1m-1 Z � m n MULTILANE ROAEDS f C+1Tl MEROElYO TRAFFIC DR UYS MAY SE REMOVED � i $PEED FDR TRDDx C-E--,. 0 O LA = G7 v W C.) i ENTRANCE _w IF ■ - ■ - ■ • --a Mr • ■ - ■ 1 4r ■� ■ - ■ • = Z - = 1T mw,9-12 2t✓ BARRIER OAP E,02, LLI en C A SEE STD. 4 01LEFT SHERE ET 3, ~ U �^ O CD = C� ZU ACCESS POINT A 1--= � MMMMMMM ■ • • ■ • ■ • • • • • • MMrMr0MMMr0MMMMMMM�M0M MMM arm 6 M� O F--E n = - Z TEMPORARY A ~ } • i ~ M ■ w ❑ E--1 Q O CO - - -SEE BARRIER ■ 9173 1101Ti SHEET = z S FOR BARRIER FLARE RATES cm F}-E Oil r F1 ❑ Z .r• .r - OANMI CUSHION 1S REOIII RED (THEN -TRUCK BARRIER yaR SS > O'. ENTRANCE WIH 12 P. r Q ALRNr :.AriE Li09aRES MY RE UMO WHEEN ALLCMED BY ME ENRINEER. HAUL ROADS FOR BE p2-LANE:. 2-WAY ROADS TRUCK � m Z ENTRANCE • TRUCK 2-LANE, 2-WAY ROADWAYS � PREPARED ENTRANCE W LU � CO O Y 1R14-12 0. ACCESS ` 4A % SIGNS SHOWN FOR DINE APPRCIACH. BUMP ST SAYE SIORIM APPLES FOR O STOP BOTH APPROACH DIRECTIONS LL co Uj N 1--1 POINT I W2O-7a Wg-t N3--0 W14-12 A 48" Y 48" ,8" Y'�8" 46" % aA'' f ,B" A ,B" SEE 1®TE 5 1� m i w y HAUL ROAD DD' q B C C W n Mz TRUCK . b C! a D1 in V ENTRANCE r M r cc W I --I Mil. ~ C7 Q `1a-,a a O W ¢> m WEN D]RECTED BY THE Eh101NEER, TRAFFIC MT BE STOPPED TO ALLOW WORK VEHICLE ACCESS. USE THE EAME SION- USE TYPE III BARB OF INCE5 MEEK NMI. ROAD IS hvT BEPMEG Uj FOR HAUL ROADS AS SHOWN IN THE ADIAct-W DETAIL. Z n GENERAL NOTES N m 1- MOUNT SIGNS ON BOTH LEFT AND RIGHT SIDES ON DIVIDED ROADWAYS. SIGNS ARE REQUIRED 5- WHEN NOT SPECIFIED IN THE PLANS OR BY THE ENGINEER, PAYMENT FOR CONVENIENCE WILL NOT (0 m ONLY ON THE 'RIGHT SIDE OF THE ROADWAY FOR UNDIVIDED ROADWAYS. BE MADE FOR FLAGGERS. z o LLI Q m 2- PROVIDE MINIMUM STOPPING SIGHT DISTANCE FOR EACH FLAGGER LOCATION. N 3- REFER TO STD. 1101.11 SHEETS 2 & 4 FOR STOPPING SIGHT DISTANCE AND SIGN SPACING. LEGEND ■ PORTABLE CONCRETE SARRTER 4- UPON COMPLETION OF EACH HAULING OPERATION, REPAIR, SWEEP, AND RESTORE THE ROADWAY w+r TEMPORARY CRASH CUSHION TO BE SAFELY TRAVERSABLE AT NORMAL OPERATING SPEEDS. ■ DRUM 5- "BUMP" SIGNS (W3.1) ARE REQUIRE➢ ONLY IF A BUMP OVER THE ROADWAY EXISTS AS A RESULT F• STArIONARY SIGN OF IMPLEMENTING THE HAUL ROAD. USE FLAGGERS AT ALL TIMES TO STOP TRAFFIC WHEN BUMPS 16 PORTABLE SIGN ARE LOCATED ACROSS THE ROADWAY. CONSTRUCT BUMPS TO PROVIDE A SMOOTH TRANSITION FOR f FLAGGER TRAFFIC CROSSING THEM. REMOVE BUMPS PRIOR TO ALLOWING TRAFFIC TO RESUME NORMAL f DIRECTION OF TRAFFIC FLOW OPERATING SPEEDS. SHEET I OF 1 SHEET 1 OF 1 1 1 0 1. 05 1101.05 O m z O rn v H E"E Z Q >E-"•,O= ca m0m�� rZE�C70 LL__j z�=y 0065m _ a � aeno4 a6o"m U~7�LL0J Cs2�z CC OUjOrr a� z 1-4 Ln0 a [V H r d �p r a CD N 0 Li 0 > J Ir Z w Z STATIONARY OR PORTABLE SIGNS o Q CO T- DISTANCE M ,T. RIM Z H REPEAT FOR ANY CONSECUTIVE STONB L ILI-1-11 TO In SE(W L LIBTANOE 10 YNo 8IGN L DISTANCE IO 1ST SCp4 r r r = C C $ FIT <0 = Q y v z LU O 0 LIU0 �>] F lu REFERENCE CC CC J Q Q v POINT ❑ O m Tnmv m ¢DEL � V� Z LU I-y Z = UI LL O Z - CD W rn LU LPL r m m GENERAL NOTES U Q cc rn N EL H uD 1- REFER TO 2309 MUTCD. 2• USE THIS STANDARD DRAWING IN CONJUNCTION WITH OTHER TRAFFIC CONTROL ROADWAY STANDARD DRAWINGS WHERE SIGN SPACING DISTANCES A, B. C. ARE SPECIFIED, 3- APPLY THE ADVANCE WARNING SIGN SPACING CHART WHERE A SERIES OF 2 OR MORE SIGNS ARE USED. ALL SIGN SPACING DIMENSIONS ARE APPROXIMATE. FIELD ADJUST AS VARIOUS CONDITIONS OCCUR, SUCH AS LIMITED SIGHT DISTANCE, OBSTRUCTION INTERFERENCE, ETC. HEET 4 OF 4 SHEET4 OF 4 11101.111 11101.111 ADVANCE WARNING SIGN SPACING CHART RECOM11E N0EG DISTANCE aETNEEX SIGNS POSTED SPEED LIMIT (MPH) [FEET(x 0 o a 35 230 2D0 2GD 4O.50 �50 35C. 33D b6 50D SUU 5GE7 CONTROLLED ACCESS ROADS 10DO 7500 27D0 v z m O OTen' TO 200, PREPARED NI LAN tOAD } HC -•E • z TO STOP EAO W28-rN a Q Q n F- QmmCIO W9-e Y20-+ 48'" % 46" 48" % +8" AN" % a6" z cc = C.7 FE G7 > MA%. YA%. LL JEHZ � � � © O ,.1 M z .. ULJ mZ>m �U�O(�3 zs�oa f �y � �•• ¢=~Zw Cl = 4.1 Z �z oleo, 0 N >� tJO1-- O = p E--E C O UI= WORK AREA z a E /� E �. J b C E; I {r R ry O nrl.wAr pprH (� [ H I�ti U) O 1 TRAFFIC,wSO'-TOO' SPACE "01 48'" a8" % a0" INSET FOR 2 LANE ROADWAYS ❑ WITH 2-WAY TURN LANE ALL OTHER DEVICES ARE THE SAME AS ABOVE N d m R1 z D v U- w �3r y F- ry O ry CEHITT LAM CTNIN LNM ClO5E0 JS WORK AIEA A _ r' Ci0.F➢ 0 LLJ z Cl3 z • k :8" AD^ Q 48 ■ 48"x ■� j D - IOC� cc V { TTD.xAr nOwn T1IAFFIi 9TR FAY �B.rlaETAPER j ❑ � Q O TAPER BUFFER LU O On 6q' 1US. $PACE SPACC UDC Q_ O Q m a GENERAL NOTES FOR FLAGGER OPERATIONS GENERAL NOTES FOR PILOT CAR OPERATIONS z J 0 p 1- REFER TO STD. 1101.11 SHEET 4 FOR SIGN SPACING. 1- USE PILOT CARS WHEN DIRECTED BY THE ENGINEER. Q 1 !•} � CONES 2- INSTALL LANE CLOSURES WITH THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE 2- IF ROADWAY WIDTH IS LESS THAN 22 FEET (EDP TO EDP CONES MAY NOT BE REQUIRED IF- UPSTREAM SIDE OF TRAFFIC- ALONG WORK AREA AND AT THE DISCRETION CF THE ENG CONES MAY BE GMITTED ALONG THE WORK AREA I� USING A PILOT CAR. DQ � 3- REMOVE LANE CLOSURES AGAINST THE TRAFFIC FLOW, BEGINNING WITH DEVICES ON THE = � Z N Z DOWNSTREAM SIDE OF TRAFFIC. 3- CONES ARE ALWAYS REQUIRED IN THE UPSTREAM AND DOWNSTREAM TAPERS. F�-E Q CV m � G7 4- PLACE CONES THRU THE WORK AREA AT THE MAXIMUM SPACING EQUAL IN FEET TO 2 TIMES 4- MOUNT SIGN G20.4 "PILOT CAR FOLLOW ME" AT A CONSPICUOUS POSITION ON THE REAR OF J m THE POSTED SPEED LIMIT. THE PILOT VEHICLE- �yE r m DD 5 PROVIDED LANEAT }} MEASURED FROM THE BEGINNING THEEOF (REFER TORSTDAC1101.111TSHEETT2}PING SIGHT DISTANCE IS 5- OF THE MERGELTAPERETOHTHEONE LU W Z o N O THESFLAGGER END(OF LANE CLOSUR05URE, � W 6- DO NOT STOP TRAFFIC IN ANY ONE DIRECTION FOR MORE THAN 5 MINUTES AT A TIME. S- ADVISE RESIDENTS AND BUSINESSES WITHIN THE LANE CLOSURE LIMITS ABOUT METHODS OF J M SAFE EGRESS AND INGRESS FROM DRIVEWAYS DURING FLAGGING AND PILOT CAR OPERATIONS. , Q 7- DRUMS OR SKINNY -DRUMS MAY BE USED IN LIEU OF CONES. REFER TO ROADWAY STANDARD CV DRAWING 11DO.01 FOR SKINNY -DRUM REQUIREMENTS. B' USE FLAGGERS TO CONTROL TRAFFIC AT INTERSECTIONS AFFECTED BY THE LANE CLOSURE. LEGEND PILIACEDMENT APPROXIMATE FLAGGERS L250TFTT_AINI AOVRNGFTOFNTHEI WITH AGGFR_ FORAHEAD SIIGNALII SIGNS ■ ■ FLAGGER INTERSECTIONS PLACE SIGNALS IN THE FLASH MODE AND RECOMMEND THE USE OF LAW ENFORCEMENT. GONE 9- REFER TO 2009 MUTCD, CHAPTER 6, FOR FLAGGER CONTROL, REQUIREMENTS, AND PROCEDURES. PORTABLE SIGN 1O DO N07 EXCEED A 1 MILE LANE CLOSURE LENGTH UNLESS OTHERWISE SHOWN IN THE TRIP OR f DIRECTION OF TRAFFIC FLOW AS DIRECTED BY THE ENGINEER. FEET 1 OF 15 SHEET 1 OF 15 11101.02 1 1 D 1 . O2 n m F--1 f++ v C.) H FFI F-E C1l -4 C7 = C-) n C M z -� m > U > Q v xor� v m = m � Z I••I z N " r- _ H-1 N -1 -r1 G7 W = r m CA 11� 01.11 EXAMPLE OF "L" & "W" DESIGNATIONS sill-D. y Sol* • i so** N SHLD. TAPER LENGTH CRITERIA FOR CHANNELIZING DEVICES IN WORK ZONES TYPES OF TAPERS TAPER LENGTH UPSTREAM TAPER MEA4IM TAPER......... .................................... L MINIMUM RHTFT W TAPER..........--.--.--.-- ----ls L MINIMUM TYO "Y TRAFFIC TAPER ................. ----bO TOO FEET MA%IIAUY DONN57REAN TAPER...........................................100 Fk ET WAxl YU11 QUICK REFERENCE -"L" DISTANCE TABLE MINIMUM LONGITUDINAL DISTAACE "L" (FEET) (ROUNDED VALUES) PDSTED SPEED LATERAL WIDTH "Nf" (FEET) s' EXPH) 1 2 3 4 5 e 7 a 9 IO 11 12 20 ,0 - 2D 30 35 4'` '•O .55 GC 70 75 SO 25 15 25 35 45 55 65 75 85 95 105, 115 12E 30 15 JD 45 60 75 90 105, 12C 135 150 165 16, 35 25 45 65 U5 105 125 145 165 105 205 225 'c45 40 3U 55 aC 110 135 190 190 215 2a0 270 205 92,: 45 45 90 135 1 a b 22 E; 270 315 Sal: 405 a50 495 5a:: 5D So :00 15D 200 25D 30D 35O �00 4;D Sob S50 $05 SS 55 ,1O 1R5 220 275 330 305 44D 495 55O 805 SRO aD 60 120 180 240 300 360 420 48D 540 EDO BGD 72a a9 G5 13D 195 260 325 390 4�5 520 585 550 715 780 70 7D ;4❑ 2'0 280 35D 420 4WD 56B 830 7130 770 840 GENERAL NOTES 1- TABLE FOR "L" DISTANCE IS BASED ON CHANNFLIZATION TAPFR FORMULA FROM THE M.U.T.C.D, WHERE; SPEED LIMIT FORMULA 40 MPH OR LESS L,N W x S2 SO 45 MPH OR GREATER L.IX W x S L = MINIMUM TAPER LENGTH IN FEET (LONGITUDINAL DISTANCE) W = WIDTH OF OFFSET IN FEET (LATERAL DISTANCE) S = POSTED SPEED LIMIT, DR OFF-PEAK 85 PERCENTILE SPEED IN MPH PRIOR TO WORK STARTING, OR THE ANTICIPATED OPERATING SPEED IN MPH 2- 1" DISTANCE IS FOR APPLICATION WITH CHANNELIZING DEVICE AND PAVEMENT MARKING TAPERS AND TRANSITIONS. CHANNELIZING DEVICES INCLUDE DRUMS, CONES, TUBULAR MARKERS, BARRICADES, RAISED ASPHALT ISLANDS, AND VERTICAL PANELS. v Z m Q n v� Q }i Z=��' m0m�� co �JF-1"EZ l4Z�=n oo�x G7 O It] C7 � = Tl 2 > TTI LATERAL CLEARANCE: SAE. 2 w a = < .. 3' MINIMUM MW TRAYEL LANE. IFTCATRO $PECI FrCATIDN9 pna�� Sim ATSATE 0 cc �^ = co 0 PLACE SIGN HEYOrm SHOINLDF3E SURSMR NATERLAL Q � I --I F- Z Z U r TI MINY IF IT CANNOT BE INSTALLI0 LU OZ LL - J �„] H PLUMB. ITSI AN 15 PLACED YRTHIN nA LANE CLOSUAI OR ON THE O (/] a TRANELMY THE CLEARANCE z 1.4 (f7 E APPLIES FROM THE OPEN LANE N I> -I r �© MOUNTING HEIGHT DIMENSIONS: FDA TNC-LANE, TWO-WAY RCADKAVf, INCLUDING, LU V THOSE PITTH CONTINWL3 LITT TIAN LANFS, r� THE HEIG BE,-1'IEEY ROM1DWAY TB SIGN SHALL y Z Z m O EE I' YIMIYDY. FOR c � cc Z H ALL OTHER R0A11NAT9 THE HEI6W SETYCEm LL SEAMY TO SION SHALL BE 5' MENINJM. jr 1.4 W a rrE ---- i�i»ii------i-Sri.-----------------•---. _-•--------------------- ..III y = PAVED SHOULDER TRAVEL LANE Z rE J m H m vI � W z v IF SuPPLCNCWAI PANEL 13 MQUINEII SHOULDER POINT n O Lwil O USE A S' NINIVAI EEIMT TO WIN 81AM N H- v a WFTH A 3' MINIMUM HEIGHT TO PANEL J m a =� a DO m p Q _ ao = y ij LU cs �m J = n y Q � r h•1 � � a+�a� aN� GENERAL NOTES LuO� C z n 1- DIMENSIONS SHOWN ARE MINIMUM VALUES. MOUNT SIGNS SO THEY WILL BE CLEARLY VI$IUL.Z TO 0 m APPROACHING TRAFFIC EVEN WHEN SIGNS ARE MOUNTED BEHIND TRAFFIC CONTROL DEVICES SUCH AS DRUMS, BARRIER, OR OTHER OBJECTS. 2• ALL PORTABLE SIGNS AND STANDS MUST MEET OR EXCEED THE REQUIREMENTS OF NCHRP 350 FOR CATEGORY II DEVICES. USE PORTABLE WORK ZONE SIGNS AND STANDS SPECIFICALLY DESIGNED FOR ONE APIOTHER. 3- ALL PORTABLE WORK ZONE SIGNS AND STANDS MUST RE LISTED ON THE ❑EPARTMEN"T'S APPROVED PRODUCTS LISTAThtt ps: Ilapps.dot.state.nc.us/ vunderjappruvedproducts . HEET 1 OF 1 SHEET 1 OF 1 11110.021 1110.02 Z O �r Q Q ���� LL_ J 1- 4 Z O p�2 LL Q U cc CO LL00 LL J OC7Ud 1.-4 _ LU H LL! ❑ N W J m 0 LL w N i-y O J I I z .R LU Cr M Z LLJ y <cc E- Cr 0 U L) 0 0 Cr o O Q LL LOU < U ~ O Q C] C0 C.3r W LL J LL. H 1101 .111 © m SHOULDER CLOSURE ON CONTROLLED ACCESS FACILITIES - ? 50 MPH c C Ew TRAVELWAY a�v0 z�L) ■ • • ` `•■ mzms� H -1 > p LL-30-"m O = O n ( ] rm nI SOD• SHOULDER CLOSURE TAPER W MIN. YIORK AREA TOO' 75 L SUFFER LENGTH VARIER SHOULDER ( PAVED OR UNPAVED) � 1n _ Lli d Z li � v cc C Z III to 0 O -0 -T Mal-pA "ff" ET +Z `V3 ¢ ~ Z Z LLIC7i„y ULD" s® LL 0QaWIN•4 Nz�3a N Z 90" v'z SHOULDER CLOSURE ON DIVIDED FACILITIES - 55 MPH c o y TRAVELWAY Swum. CLOSURE TAPER SD YIN. M RK MER s0' SHOULDER % L 8,1FAE t LDWH VARIES xm. (PAVED OR UNPAVED)m sA_•3'a "90"X24' m o O GG) LWFT4" = SHOULDER CLOSURE ON UNDIVIDED ROADWAYS v CO (SEE NOTE 5) Q CC N W c J a Cr SHOULDER CLOSURE TAPER 5D' YIN, TORK AREA 6G' SHOULDER ■ M '% L BUFFER LENGTH VARTES YIN. { PAVED OR UNPAVED) rz N Q HOMILD WORK H m -B C4 O = GENERAL NOTES w LU y1- PLACE SHOULDER CLOSURE SIGNS ON THE SAME SIDE AS THE SHOULDER THAT IS CLOSED. 2- PLACE DRUMS IN THE SHOULDER TAPER AT THE MAXIMUM SPACING EQUAL IN FEET TO THE POSTED SPEED LIMIT. THE MAXIMUM SPACING OF DRUMS ALDNG THE WORK AREA IS EQUAL IN FEET TO 2 TIMES THE POSTED SPEED LIMIT. LEGEND 3- USE STATIONARY SIGNS FOR LONG TERM OPERATIONS (LONGER THAN 3 DAYS). • DRUM 4- REFER TO STD. 1101.11 FOR "L" DISTANCE AND SIGN SPACING. p STATIONARY OR PORTABLE SIGN + DIRECTION OF TRAFFIC FLOW HEET 1 OF/y1 SHEET 1 OF 1 11101 11101.041 .04 5- THE TWO-LANE, TWO-WAY DRAWING MAY BE APPLIED TO UNDIVIDED, MULTI -LANE FACILITIES. O vm H 1-4 ' Z _� v rF-"_ � ca F-4m � _> =ozylm =cn0a Z Ny 0 -n OOrE n� > Ln 0 Q z C �1 z IT .�W...AA G7 FIT v / N Ca = 00 M wz Q0 00 Cn DO E� v v v � �n v ^N^g Y■ GT1 Z � > _j � as m W m N DESIGN SPEED (MPH) MINIMUM SIGHT DISTANCE MINIMUM LONGITUDINAL BUFFER SPACE (FEET) STOPPING SIGHT OISIANCE (FEET) PASSING SIGHT DISTARCE (FEET) 30 2Do '990 05 36 250 t2B0 t70 40 3D5 1470 155 45 360 1625 1R5 50 42S +835 240 55 495 "985 290 90 570 2135 345 55 645 2265 4D5 70 730 24BO 470 75 820 2560 540 90 810 26Sa .15 GENERAL NOTES 1- TABLES ARE BASED ON THE AASHTO GREEN BOCK "A POLICY ON GEOMETRIC DESIGN OF HIGHWAYS AND STREETS" AND T14F "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES". MINIMUM SIGHT OTSTANCE VALUES ARE FOR PASSENGER CAR VEHICLES ON WET AND LEVEL ROADWAYS. CONSULT THE AASHTO GREEN BOOK TO MAKE FINAL DETERMINATION OF STOPPING SIGHT DISTANCE REQUIREMENTS. 2- BUFFER SPACE TABLE I5 BASED ON THE RRAKING DISTANCE PORTION OF STOPPING STCHT DISTANCE FOR WET AND LEVEL PAVEMENTS. 3- USE OF STOPPING SIGHT DISTANCE IN TRAFFIC CONTROL PLAN APPLICATIONS INCLUDES PROVIDING SIGHT DISTANCE FOR TRAFFIC APPROACHING A LANE CLOSURE. PROVIDE 2-LANE, 2-WAY ROADWAYS STOPPING SIGHT DISTANCE TO THE FLAGGER. FOR LANE CLOSURES ON MULTILANE ROADWAYS PROVIDE STOPPING SIGHT DISTANCE TO THE BEGINNING OF THE LANE CLOSURE MERGE TAPER, OR FLASHING ARROW BOARD. EXTEND LANE CLOSURES AT THE BUFFER SPACE SUCH THAT STOPPING 51014T DISTANCE IS PROVIDED. 4- USE OF MINIMUM PASSING SIGHT DISTANCE TABLE IN TRAFFIC CONTROL PLAN APPLICATIONS INCLUDES PROVIDING SIGHT DISTANCE REQUIREMENTS FOR PLACEMENT OF PAVEMENT MARKING PASSINGINO-PASSING ZONES FOR 2-LANE, 2-WAY ROADWAYS. C7 Z v Tor IS- Q 1-4 C DIAMETER E.y Z NOT 1D E=Mb ¢ nCh Q 0 T- ORANGE ULTRA VIOLET RASE DIAMETER Z � � L) r-E C7 L J E" m z = H > STABILIZED IMPAGT RESISTANT PLASTIC Z 279>ym LJUQ�2 Q �0�C) H = Z Uj �G)35 TIRE BALLAST �C�¢ man z �� a� a H C7 E1[TTOINAL DIAYET ER 35'EMTN1 TO 35.5'1xA%ECn 1--4 r W a Z CIRCUMFERENTIAL N° srR revs TYP If„M. r d ALTERNATE ORANGE & WHITE RETROREFLECTIVE STRIPES, 2 ORANGE $ 2 WHITE COVERING - ENTIHE OUTSIDE MINIMUM 1 o V' M%. TYpICA Ir-I HE IYIEEX 8TR lAE8 �r {fj ALL RUNNER COLLARS MUST BE BLACK IN COLOR Z = mQ, FREE Or AHY COLORED PAINT $--[ YALLAST fA LIAR SHDDLD HAVE SADD LDNTAC-I WITH THE BARREL FLANDE AM 94LLAST OUTER < EDUE NUST LAM' FLAT WITH ROAD SURFACE cc `> CRSIM9 THAT USE TIRE BALLA9T3 ARE MNUrMTUREU 0 !•M Z SPECIFICALLY FOR THAT PURPOSE. DO NOr USE TURF MLLASIS WITH OHFN OPUM PURPOSE., S, C m Q CC 3 a z o Q � 21" VIM. TO 2M" YA%. o1AMETER i Sn Z GENERAL NOTES E-I T1 1- BALLASTING SHALL BE ACHIEVED BY THE SAND BAG, TIRE-SIDEWALL, DR PREFORMED WEIGHTED BASE O METHODS. USE THE TIRE BALLAST AS SPECIFIED BY THE MANUFACTURER. 00 NOT PLACE BALLAST z � ON TOP OF THE DRUM. LU 2- IF NECESSARY PLACE THE NAME OF THE AGENCY, CONTRACTOR, OR SUPPLIER ON NON-RETROREFLECTIVE DRUM SURFACES. SHOW THE LETTERS AND NUMBERS USING A NON-RETROREFLECTIVE COLOR AND NOT OVER 2" IN HEIGHT. 3- USE TYPE 3 OR HIGHER HIGH INTENSITY PRISMATIC SHEETING, 4- SEE THE DEPARTMENT'S APPROVED PRODUCT LIST AT https:l lapps. dot. state. nD. uslvendor/ app r0Vedproduct S. 5• REFER THE STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES FOR ADDITIONAL INFORMATION. HEET 1 OF 1 SHEET 1 OF 1 1 1 3 0.0 1 1 1 3 0.0 1 Z O 1n Q H ix L) L-J0-1-4Z oocnm = Z QU°COH rj�~OLI-1 LL J O❑U]d z 1.4 = LU d (A W J.rA�L co LU Q Q 0 ~ z � N � N � Cr y ❑ C fl � °C J � = d O J fa Cn cc LL1 CD W LL am H 1101.11j FIR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 PART III V _. SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF -INSPECTION Self -inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self -inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. Frequency Inspect (during normal Inspection records must include: business hours) ---i- - ______�. (1) Rain gauge Daily Daily rainfall amounts. maintained in If no daily rain gauge observations are made during weekend or good working holiday periods, and no individual -day rainfall information is order available, record the cumulative rain measurement for those un- attended days (and this will determine if a site inspection is needed). Days on which no rainfall occurred shall be recorded as "zero." The permittee may use another rain -monitoring device approved by the Division. (2) E&SC At least once per 1. Identification of the measures inspected, Measures 7 calendar days 2. Date and time of the inspection, and within 24 3. Name of the person performing the inspection, hours of a rain 4. Indication of whether the measures were operating event > 1.0 inch in properly, 24 hours 5. Description of maintenance needs for the measure, 6. Description, evidence, and date of corrective actions taken. (3) Stormwater At feast once per 1. Identification of the discharge outfalls inspected, discharge 7 calendar days 2. Date and time of the inspection, outfalls (SDos) and within 24 3. Name of the person performing the inspection, hours of a rain 4. Evidence of indicators of stormwater pollution such as oil event > 1.0 inch in sheen, floating or suspended solids or discoloration, 24 hours 5. Indication of visible sediment leaving the site, 6. Description, evidence, and date of corrective actions taken. (4) Perimeter of At feast once per If visible sedimentation is found outside site limits, then a record site 7 calendar days of the following shall be made: and within 24 1. Actions taken to clean up or stabilize the sediment that has left hours of a rain the site limits, event > 1.0 inch in 2. Description, evidence, and date of corrective actions taken, and 24 hours 3. An explanation as to the actions taken to control future releases. (5) Streams or At least once per If the stream or wetland has increased visible sedimentation or a wetlands onsite 7 calendar days stream has visible increased turbidity from the construction or offsite and within 24 activity, then a record of the following shall be made: (where hours of a rain 1. Description, evidence and date of corrective actions taken, and accessible) event > 1.0 inch in 2. Records of the required reports to the appropriate Division 24 hours Regional office per Part III, Section C, Item (2)(a) of this permit of this permit. (6) Ground After each phase 1. The phase of grading (installation of perimeter E&SC stabilization of grading measures, clearing and grubbing, installation of storm measures drainage facilities, completion of all land -disturbing activity, construction or redevelopment, permanent ground cover). 2. Documentation that the required ground stabilization measures have been provided within the required timeframe or an assurance that they will be provided as soon as possible. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be documented in the manner described: Item to Document (a) Each E&SC Measure has been installed and does not significantly deviate from the locations, dimensions and relative elevations shown on the approved E&SC Plan. (b) A phase of grading has been completed. (c) Ground cover is located and installed in accordance with the approved E&SC Plan. (d) The maintenance and repair requirements for all E&SC Measures have been performed. (e) Corrective actions have been taken to E&SC Measures. Documentation Requirements Initial and date each E&SC Measure on a copy of the approved E&SC Plan or complete, date and sign an inspection report that fists each E&SC Measure shown on the approved E&SC Plan. This documentation is required upon the initial installation of the E&SC Measures or if the E&SC Measures are modified after initial installation. initial and date a copy of the approved E&SC Plan or complete, date and sign an inspection report to indicate completion of the Construction phase. initial and date a copy of the approved E&SC Plan or complete, date and sign an inspection report to indicate compliance with approved ground cover specifications. Complete, date and sign an inspection report. initial and date a copy of the approved E&SC Plan or complete, date and sign an inspection report to indicate the completion of the corrective action. 2. Additional Documentation In addition to the E&SC Plan documents above, the following items shall be kept on the site and available for agency inspectors at all times during normal business hours, unless the Division provides a site -specific exemption based on unique site conditions that make this requirement not practical: (a) This general permit as well as the certificate of coverage, after it is received. (b) Records of inspections made during the previous 30 days. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. (c) All data used to complete the Notice of Intent and older inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non -surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a) The E&SC plan authority has been provided with documentation of the non -surface withdrawal and the specific time periods or conditions in which it will occur. The non -surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b) The non -surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that must be reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: • They are 25 gallons or more, • They are less than 25 gallons but cannot be cleaned up within 24 hours, • They cause sheen on surface waters (regardless of volume), or • They are within 100 feet of surface waters (regardless of volume). (a) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (b) Anticipated bypasses and unanticipated bypasses. (c) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at (800) 662-7956, (800) 858-0368 or (919) 733-3300. Occurrence Reporting Timeframes (After Discovery) and Other Requirements (a) Visible sediment . Within 24 hours, an oral or electronic notification. deposition in a . Within 7 calendar days, a report that contains a description of the stream or wetland sediment and actions taken to address the cause of the deposition. Division staff may waive the requirement for a written report on a case -by -case basis. • If the stream is named on the INC 303(d) list as impaired for sediment - related causes, the permittee may be required to perform additional monitoring, inspections or apply more stringent practices if staff determine that additional requirements are needed to assure compliance with the federal or state impaired -waters conditions. (b) Oil spills and • Within 24 hours, an oral or electronic notification. The notification release of shall include information about the date, time, nature, volume and hazardous location of the spill or release. substances per Item 1(b)-(c) above (c) Anticipated • A report at least ten days before the date of the bypass, if possible. bypasses [40 CFR The report shall include an evaluation of the anticipated quality and 122.41(m)(3)] effect of the bypass. (d) Unanticipated • Within 24 hours, an oral or electronic notification. bypasses [40 CFR • Within 7 calendar days, a report that includes an evaluation of the 122.41(m)(3)] quality and effect of the bypass. (e) Noncompliance • Within 24 hours, an oral or electronic notification. with the conditions . Within 7 calendar days, a report that contains a description of the of this permit that noncompliance, and its causes; the period of noncompliance, may endanger including exact dates and times, and if the noncompliance has not health or the been corrected, the anticipated time noncompliance is expected to environment[40 continue; and steps taken or planned to reduce, eliminate, and CFR 122.41(I)(7)] prevent reoccurrence of the noncompliance. [40 CFR 122.41(I)(6). • Division staff may waive the requirement for a written report on a case -by -case basis. F)l HDR Engineering, Inc. ofthe Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 CONTRACT SHEET 38 OF 43 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Stabilize within this Site Area Description many calendar Timeframe variations days after ceasing land disturbance (a) Perimeter dikes, swales, ditches, and 7 None perimeter slopes (b) High Quality Water 7 None (HQW) Zones (c) Slopes steeper than If slopes are 10' or less in length and are 3:1 7 not steeper than 2:1, 14 days are allowed -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, (d) Slopes 3:1 to 4:1 14 ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed -7 days for perimeter dikes, swales, (e) Areas with slopes ditches, perimeter slopes and HQW Zones flatter than 4:1 14 -10 days for Falls Lake Watershed unless there is zero slope Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: Temporary Stabilization Permanent Stabilization • Temporary grass seed covered with straw or • Permanent grass seed covered with straw or other mulches and tackifiers other mulches and tackifiers • Hydroseeding • Geotextile fabrics such as permanent soil • Rolled erosion control products with or reinforcement matting without temporary grass seed • Hydroseeding • Appropriately applied straw or other mulch • Shrubs or other permanent plantings covered • Plastic sheeting with mulch • Uniform and evenly distributed ground cover sufficient to restrain erosion • Structural methods such as concrete, asphalt or retaining walls • Rolled erosion control products with grass seed POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the tmeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. A (TYP.) ES CLEARLY MARKED SIGNAGE NOTING DEVICE (18"X24" MIN.) CONCRETE WASHOUT PLAN ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER 10 MIL 1:1 PLASTI SANDBAGS (TYP.) SIDE SLO LINING OR STAPLES (TYP. =xx r SECTION A -A NOTES: 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. BELOW GRADE WASHOUT STRUCTURE NOT TO SCALE SANDBAGS (TYP.) OR HIGH APLES 10 MIL COHESIVE 6 PLASTIC LOW FILTRATION WIN111 OE SOIL BERM iSLOPE L (TYP.) NOTES: OR STAPLES 1. ACTUAL LOCATION DETERMINED IN FIELD CLEARLY MARKED SIGNAGE CONCRETE NOTING DEVICE (18"X24" MIN.) 2. THE CONCRETE WASHOUT WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY TO PROVIDE ADEQUATE HOLDING CAPACITY WITH A MINIMUM PLAN 12 INCHES OF FREEBOARD. 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. , •�.� N C A,40 .• �• �EA 18 z M. YAN HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE CONTRACT CONTRACTOR AS -BUILT AUTH. DAT WATER AND SEWER PERMITS JOB NO. P- 05808C CITY OF GREENSBORO WATER RESOURCES DEPARTMENT 04D-05 ROADWAY DESIGNED 11/2022 BY HDR SEWER 2022-013C CONST . SURVEY BY GRMS Phase IV Sewer Force Main Extension NCDEQ NOTES SHEET NO. WATER CHECKED BY 38 OF 43 100% SUBMITTAL SIDEWALK SCALE: AS NOTED S F S LEGEND D = OUTLET PIPE DIAMETER d50 = MEDIAN STONE SIZE IN A WELL GRADED APRON dmax = 1. 5 X d5D = MAXIMUM STONE DIAMETER t = APRON THICKNESS = 1. 5 X dmax L = LENGTH (DETERMINED FROM SECT. 8. 05) W = WIDTH @ END OF APRON (DETERMINED IN SECT. 8. 06 DEPENDING ON TA IL WA TER CONDITIONS) WIDTH @ OUTLET = 3D NOTES., RIP -RAP PIPE OUTLET PROTECTION APRONS ARE TO BE DESIGNED ACCORDING TO THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, SECTION 8. 06. 1 - 8. 06. 4 PLACE RIP -RAP AROUND PIPE AS DIRECTED BY THE FIELD ENGINEER. C/ T Y OF GREENSBORO STANDARD PIPE OUTLET STD. NO. REV. 03-97 W EROSION CONTROL DEVICE 422 0 S N f!! N W RIP -RAP SIZE DETERMINED BY C. F. S. TOP OF BANK MIN. OF CLASS I RIP -RAP A - - - - - #4 WASHED of = STONE, 6" THICK Q -III-I I I -I IF A E FL OW CREEK INVERT W12 (35 " MIN.) 1:E1 I E I,;IIIF: -III��I RIP -RAP CREEK INVERT W SECTION A -A NOTE.' THIS DEVICE IS TYPICALLY USED 15' AWAY FROM PIPE OUTLETS LATER TO BE SPREAD INTO A RIP -RAP APRON. THIS DEVICE TO BE CONSIDERED FOR 36" CUL VERTS OR LARGER. m 0 3 A 6 C/ T Y OF GREENSBORO STD. NO. REV. STANDARD TEMPORARY SIL T 03-97 N CHECK DAM, TYPE A 433 09-10 METAL FENCE POST 14 GAUGE MINIMUM HOG WIRE (OPTIONAL) EROSION CONTROL FABRIC MAINTAIN ADEQUATE DISTANCE FOR SEDIMENT REMOVAL 6 MAINTENANCE III- 51,10 I � I I -I FI IIElIEdI1= �-IIIIII-III-III-I I -I EX. EARTH BACKFILL AND COMPACT THOROUGHL Y SILT FENCE MUST BE ENTRENCHED AND SECURED WITH COMPACTED SOIL. THE "SL ICING METHOD " MA Y AL SO BE USED 4" TO INSTALL SILT FENCE (SEE NCDENR "EROSION AND SEDIMENT CONTROL DESIGN PLANNING AND DESIGN MANUAL " SECTION 6. 62) . USE COG STD#432 STONE DITCH CHECK FOR FENCE OUTLETS AT A MAXIMUM 100 FT SPACING AND AT ALL NATURAL DRAINAGE AREAS. (SEE SHEET 2 OF 2) . NO TES: -SPACING OF POSTS USING HOG WIRE WITH APPROVED EROSION CONTROL FABRICS TO BE 8 ' -0 " ON CENTER. -SPACING OF POSTS WITHOUT HOG WIRE USING APPROVED EROSION CONTROL FABRICS TO BE 6 ' -0 " ON CENTER. POST.' METAL T-POST 5 ' -0 " OR 5 ' -0 " IN HEIGh'T DEPENDING ON FILL SL OPE (MIN. 1. 33 LB/LF STEEL CONSTRUCTION) . FABRIC.' 3'-0 " IN WIDTH (MUST BE STANDARD SPECIFICA TIONS FOR SILT FENCE - A5TM D ) WITH 12" BURIED IN TRENCH. STONE.- (IF USED) #4 WASHED STONE PLACED 1 ' -0 " DEEP A T SIL T FENCE. Q -SPLICES IN FABRIC SHOULD BE OVERLAPPED A MIN. OF 4 FT. o -MAXIMUM DRAINAGE AREA = 114 ACRE PER 100 FT OF FENCE FOR 2% OR LESS SLOPE. -SILT FENCE TO BE REMOVED AFTER CONSTRUCTION IS COMPLETE AS DIRECTED BY THE CONSTRUCTION INSPECTOR. W PAGE I OF 2 C/ T Y OF GREENSBORO o` STD. NO. REV. N SILT FENCE DETAIL 12/06 430 03/08 03/09 r r r- r; r- r•r r r r ••r r ••r r r•r• r- r r r r r •r• r r •r, r r r� •r •r r •r � r r r r •r r r r r r: r r r - r r r r r- • rr r r r r r r r r r ••r• r r r r r r r r •r r r r- r r- r r r r r • r r r ••r r r• r •r-r r rr r r r •r r - r r r• ••r , : ..,.. , ., , , •, ,• rl�l o�Qo o?O�o 00 o °pO,Ooo 0 v o0'.Ojti�000O�o°po°o oO�0°oso°°°0 o a0'o�.O.O.o,o oova.O�O�pOO°°°tooa�{� 0 0 °ppo°°1°°Oo 000 0 o0aaa�0 o0'oao00°oo°�o a°0'uo O° law- Oo°OvpOOoo°o°ro ov0,0°o0°0000 0o a °o PAo0�a00000000 00'000000'O;Oo �a.o 000 �O:Ooo�OoRoo o1v-o°v°OOooO°o.o 000.'oo� Oa OOOO°Op��O 00'00�°°000 p��000000�p9 pO° O°OOOp�OO~000 oo dv ono O,' �00� 00 0 oo-19.9 oo Oyoo oo° 00 o oo"000 oOOoo°�00o°oOOrO�o��000 ��� Ov�oO000 0 boo°o'o°o�o ° °-O��ooao o-oo 0 00)00t0?�00�0� o°o) ►000O,yji0o00 opO i �o O°o1 Ooo?ro0'1 �oato O�Oo0o0 00 0o v+a000 0o°09°O oo ° ° °O° i 00��0°��00�00�000�o OoOOi'aKoOo~ 000 oo, oa 01- °oo d o o°c�9�<e uv0$0.��r4"��zR�°a0rvsOg�j�ea�°o0o00��°°00 00o00oov0o o000p "as'�Oc��i��a�°a0 O$e0'�2��sae�s�en��sop o' oo? op°0° 000 1 °oi°a00�o0 ;?a°AoO.O+o 00�000 r a0 O��v °o�000 ~O�O ! Oio°oiOooO°O°vo0 k000 00 0 • 000°p`10,00�0 oa 000° o ° 00o°off°O'o°.�o°vto0o°°o°Oao0 y O.og.o o aP ° oY OOo'OLOtO°o.000 00 v v o 00 pOs°q.00�o0000 0 A0o°Oo�o oro*O'oo00 orto'Oo0 - ,,�;1spt0000�000o O°va000;0 00 O.Og °0 00 O°oo '' :#t��oo oRa oo roo .001. O `► o° ..:•og�c°v�aooaao0o0o°0�o,,oO,lvvolo�o000 000'00 �` oo d O;O00000rc0000a 1 t 000 -.pa.s oe. oo O �+� 0 O'a0000O.Oao •:::.���000, °0 oaa oo° 000 °�o,O° oo:0 00,0,7�•0p'►0 ° _ �rQ`-T,oiOoa000�000°�° a° aa0°°aa°°tiOvo ° °"d qc ::v�'_• 900 °..o o- . :6dAg'.°yo.,�vO�o'oo000.0 ooa.�i�::..• AF • F G - E E N S B • - • TEMPORARY CONSTRUCTION ENTRANCE DETAIL (CITY REQUIREMENTS) �. 3� 8 so\pMA (SEE MAXWITN CpG STp WITHOUT W #21g G WIgEING #q�p 1 MAXIMUM RETAINED AREA TO BE BY SILT FENCE GROUND SLOPE MAXIMUM SLOPE LENGTH DRAINAGE AREA (%) (ft.) * (SO. FT.) <2% 100 10,000 2%-5% 75 7, 500 5%-10% 50 5,000 10%-20% 25 2, 500 >20% 1 15 1, 500 WIRE BACKING SHALL EXTEND THOUGH 8°°°oe�"•e °;° LENGTH OF ROCK m ° m OUTLET COG STD. #432 STONE DITCH 8 CHECK TO BE USED FOR SILT FENCEEOUTLET .a B° ALL SIDE SLOPESARE 2: 1 8 - STRUCTURAL STONE TO BE 'CLASS B' RIP -RAP B� ''� •g8�0 - 12" THICK LAYER OF #57 e�88 ems° 8 °° e�°�° e"°m m°a?mom° `°°°°� WASHED STONE FOR EROSION ed�m CONTROL ON FACE e�8° STONE SHALL BE PLACED ON UPSTREAM SIDE OF OUTLET ONLY NO TES.' 1. NON -EROSIVE OUTLETS ARE TO BE PLACED IN THE SIL T FENCE AS SHOWN ON THE PROJECT PLANS AND AS DIRECTED BY THE CONSTRUCTION INSPECTOR. 2. NON-EROSI VE OUTL ETS ARE TO BE L OCA TED A T ALL NA TURAL DRAINAGE AREAS AND DEPRESSIONS, WITH THE EXCEPTION OF PERENNIAL STREAMS. 3. THE MAXIMUM DRAINAGE AREA IMPOUNDED AT ,EACH OUTLET MUST NOT EXCEED 114 ACRE. PAGE 2 OF 2 C/ T Y O F G R E E N S B O R O STD. NO. REV. SILT FENCE DETAIL 12105 430 03108 03109 I--2 " �I A.f TA/ 6'-0" TYP.� CONSTRUCTION SPECIFICA TIONS 1. REMOVE AND PROPERL Y DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONAL MA TERIAL . 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. 3. ENSURE THAT THE TOP OF THE BERM IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND CLEANOUT. 5. VEGETATE THE BERM IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. MAINTENANCE INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION BERM. CAREFULLY CHECK OUTLETS AND MAKE TIMEL Y REPAIRS AS NEEDED. WHEN THE AREA PROTECT- ED IS PERMANENTLY STABILIZED, REMOVE THE BERM AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPRO- PRIATELY STABILIZE IT. C/ T Y OF GREENSBORO STD. NO. REV. TEMPORARY EARTH BERM W 440 0 N N N J a CLASS B STONE 5 s� oo F� ISOMETRIC VIEW 1 '-6" MIN. y f NA TURAL GROUND 9 .. 1 ' -0 " THICK Q MIN. #57 STONE CLASS B STONE o W 000 O �', DITCH FLOW - o o o I O 00 00 INVERT) Ono O I I I I I I I I L_--- --I OPTIONAL TYPE B -7 SILT BASIN (SEE NCDOT DGN 1530. 02) TYPICAL LONGITUDINAL SECTION 18 " MIN. NATURAL GROUND 1 CLASS B STONE J MIN. / KEY STONE / INTO BANK / DI TCH N, / TYPICAL CROSS SECTION NOTES.' o ENSURE THAT THE DRAINAGE AREA ABOVE THE CHECK DAM DOES NOT EXCEED 114 ACRE WITHOUT o TYPE B BASIN (2 ACRES MAXIMUM) STABILIZE OVERFLOW AREAS ALONG THE CHANNEL TO RESIST EROSION CAUSED BY CHECK DAMS. 0 ClT Y OF GREENSBORO STANDARD TEMPORARY STD. NO. REV. 12106 09/10 STONE DITCH CHECK 432 06109 1.12109 SIGN PLACE TREE PROTECTION FENCE AT THE CRITICAL ROOT ZONE, WHICH IS A CIRCULAR AREA EXTENDING OUT 1.0 FT FROM THE TREE'S TRUNK FOR EVERY i.0 INCH OF TRUNK DIAMETER MEASURED 4.5 FT ABOVE GRADE WOOD OR METAL POST. ORANGE SAFETY FENCING IS REQUIRED. SPACE POSTS ON 8' INTERVALS. NOTES:- 1. SEE PLANS FOR LOCATION OF ALL TREE PROTECTION FENCES. 2. ALL TREE PROTECTION DEVICES MUST BE INSTALLED PRIOR TO LAND DISTURBANCE, INCLUDING THE CUTTING OF ANY TREES, AND MUST BE INSPECTED BY THE URBAN FORESTER OR HIS DESIGNEE. 3. NO GRADING, TRENCHING, FILLING OR STORING OF MATERIALS IS TO OCCUR IN THE TREE PROTECTION AREA. 4. TREE PROTECTION FENCE MAY NOT BE REMOVED WITHOUT THE APPROVAL OF THE URBAN FORESTER OR HIS DESIGNEE. 5. THE TREE CONSERVA TION AREA SHOULD BE DESI GNA TED WI TH "TREE CONSERVA TION AREA " SIGNS POSTED VISIBL Y GN THE OUTSIDE OF THE FENCED -IN AREA. SIGNS MAY NOT BE POSTED ON THE TREES. SEE EXAMPLE BELOW. TREE CONSERVATION AREA WNA DE CONSERVATION DE A"OL EXAMPLE SIGN 16" X 12" SIGN i" BLOCK LETTERS BLACK LETTERS ON WHITE BACKGROUND 1/4" BLACK BORDER ALL WEATHER MEDIA 100' SUGGESTED SPACING BETWEEN SIGNS q C/ T Y O F G R E E N S B O R O STD. NO. REV. STANDARD TREE PROTECTION DETAIL p tO3-08 440 06-08 -10 CONTRACT SHEET 39 OF 43 •a'tN CARD -, oF�ss�p QEA 18 ,0 021/ /aok '114 M. YP�.► HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE CONTRACT CONTRACTOR AS -BUILT AUTH. DAT WATER AND SEWER PERMITS JOB NO. P- 05808C CITY OF GREENSBORO WATER RESOURCES DEPARTMENT Q4D-ftc O6 ROADWAY DESIGNED 11/2022 BY HDR SEWER 2022-013C CONST . SURVEY BY GRMS Phase IV Sewer Force Main Extension STANDARD EROSION CONTROL DETAILS SHEET NO. WATER CHECKED BY DTB 39 OF 43 100% SUBMITTAL SIDEWALK I I I I I I SCALE: AS NOTED INLET METAL FENCE POST 14 GAUGE WIRE SCREEN WITH 1/4" OPENINGS #57 STONE I I I I I I I I I : I I o I I I I I I I I I I I - J F '/ LOW i f SEDIMENT \ I / TYPICAL VIEW / STONE / WIRE INLET PROTECTION NOTES.' POST TO BE SET AT EACH CORNER OF INLET. IN ANY CASE THERE IS TO BE NO MORE THAN 5 , -0 " BETWEEN POSTS. POST METAL T-POST 5'-0" IN HEIGHT, 4 FT MAXIMUM SPACING WIRE SCREEN 3'-0" IN WIDTH WITH 1/4" OPENINGS STONE #57 STONE TO BE PLACED 15 " DEEP A T WIRE SCREE 3OF3 CITY OF G R E E N S B O R O 0 STANDARD STORMWA TER INLET STD. NO. REV. W N PROTECTION MEASURES 4,31 DEC Zoos FLOW FLOW CLASS "B" RIP -RAP �12" MIN. 3' AI MIN 12" MIN. I I 12" MIN. ROADWAY SHOULDER ti �• 24" DIVERSION POINT STORAGE L O 7 MIN. ------------------------ AREA "' D ; ' FLOW STORAGE VOL. -MIN. 3600 CU. ORIG. FT. PER ACRE DISTURBED AREA --Spb1)Nti------------ #5 OR #57 --- ------------------ 18" T MIN. WASHED STONE t36" PIPE MAX. EXCAVATED SEDIMENT STORAGE PROFILE VIEW NOTES.' 1. INSTALL CLASS B RIP -RAP IN A SEMI -CIRCLE AROUND THE PIPE INLET. BUILD UP THE STONE HIGHER ON EACH END WHERE IT TIES TO THE EMBANKMENT. THE MINIMUM CREST WIDTH OF THE RIP -RAP SHOULD BE 3 FT, THE MINIMUM BOTTOM WIDTH SHOULD BE 11 FT, AND A MINIMUM HEIGHT OF 2 FEET - BUT SHOULD ALSO BE 1 FT LOWER THAN THE SHOULDER OF THE EMBANKMENT. 2. A 1 FT THICK LAYER OF #5 OR #57 WASHED STONE SHOULD BE PLACED ON THE OUTSIDE SLOPE OF THE RIP -RAP. 3. THE SEDIMENT STORAGE AREA SHOULD BE EXCAVATED AROUND THE OUTSIDE OF THE STONE SEMI -CIRCLE 18 " BELOW GRADE. 4. INSPECT EROSION CONTROL DEVICES AT LEAST ONCE WEEKLY AND AFTER EACH RAINFALL PRODUCING E EVENT OF 1/2 " OR GREA TER. EXCA VA TE SEDIMENT FROM THE DEPRESSION ONCE ACCUMUL A TED DEPTH HAS REACHED 1/2 THE DESIGN DEPTH OF THE TRAP TO MAINTAIN ADEQUATE STORAGE AREA. E REPLACED ANY CONTAMINATED STONE. i 5. ANY RIP -RAP DISPLACED FROM ITS ORIGINAL LOCATION SHOULD BE REPLACED IMMEDIATELY. 6. ONCE DISTURBED AREAS HAVE BEEN STABILIZED, FILL THE DEPRESSION AND ESTABLISH FINAL GRADE AND STABILIZE WITH GROUND COVER. 7. THE STORAGE VOLUME REQUIRED IS 3600 CUBIC FT PER ACRE OF DISTURBED AREA. 0 o Cl T Y OF GREENSBORO n n STD. NO. REV. ROCK PIPE INLET PROTECTION 453 06/09 SPACING OF WA TER BARS SLOPE SPACING (%) (FT.) <5 125 5 TO 10 100 10 TO 20 75 20 TO 35 50 ` >35 25 nPE SECTION VIEW OF WA TER BAR NOTES.' 1. INSTALL WATER BARS IMMEDIATELY AFTER CLEARING OPERATIONS. 2. DISK OR ROUGHEN THE SURFACE PRIOR TO PLACEMENT OF FILL FOR THE BERM. 3. TRACK OR TAMP THE RIDGE TO COMPACT IT TO THE DESIGN CROSS SECTION. 4. DIVERSIONS SHOULD BE INSTALLED SUCH THAT THE SLOPE IN THE CHANNEL SECTION DOES NOT EXCEED 2%. 5. LOCATE THE OUTLET OF WATER BARS TO UNDISTURBED AREAS. IF THE AREA IS NOT ADEQUATE TO RESIST EROSION, STABILIZE THE AREA WITH RIP -RAP (REFER TO COG STD. #422) . 6. IMMEDIATELY SEED AND MULCH AREAS THAT WILL NOT BE SUBJECT TO CONSTRUCTION TRAFFIC. IF EQUIPMENT WIL L BE CROSSING THE DI VERSION, STABIL IZE WI TH S TONE OF ADEQUA TE SIZE TO WITHSTAND THE TRAFFIC. 7. PROVIDE EXCAVATED SEDIMENT STORAGE AND COG STD. #432 DITCH CHECK AT THE OUTLET OF DIVERSIONS UNTIL DISTURBED AREAS ARE ADEQUATELY STABILIZED. 3, 600 CU. FT. OF STORAGE VOLUME IS TO BE PROVIDED FOR EACH ACRE OF DISTURBED AREA DRAINING TO THE DIVERSION. B. PERIODICALLY INSPECT RIGHT-OF-WAY DIVERSIONS FOR WEAR AND AFTER EVERY RAINFALL OF ONE HALF INCH OR GREATER. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA ANO REPAIR THE BERM. CHECK OUTLET AREAS AND MAKE TIMEL Y REPAIRS AS NEEDED. 9. WHEN ALL AREAS A80VE THE DIVERSION HAVE BEEN ADEQUATELY STABILIZED, REMOVE THE BERM g AND STONE / RIP -RAP AND FILL THE CHANNEL TO BLEND WITH THE NATURAL GROUND. SEED AND MULCH ALL REMAINING DISTURBED AREAS. E 0 Cl T Y OF GREENSBORO N WATER BAR DETAIL STD. NO. REV. (RIGHT-OF-WAY DIVERSION) 454 06/09 SEE INSET A 12" EXCELSIOR WATTLE 1X\ DIA. 5� TYPE 4 EROSION CONTROL MATTING BACK SLOPE \ i 2' UPSLOPE STAKE 2 IN. � SEE INSET C EDGE OF PAVEMENT NATURAL GROUND I II �2' DOWNSLOPE MATTING I_ STAKE CROSS SECTION - TRAPEZOIDAL DITCH 2' UPSLOPE STAKE Im NATURAL GROUND ENSURE ADEQUATE CONTACT IS MADE_ _ - 2' DOWNSLOPE WITH GROUND USING MATTING - II STAKE WOODEN STAKES 6 WIRE STAPLES. CROSS SECTION - VEE DITCH PAGE 1 OF 2 0 CITY OF GREENSBORO STD. NO. REV. WATTLE WITH POLYACRYLAMIDE (PAM) 12/10 457 CONTRACT SHEET 40 of 43 O N \ \ \ Ll� 0 N LL N N N PUMP PROPOSED I 20' PERM. 0EARTH BERM EASMENT (MIN.) - �I N � 00 TEMP. CONSTRUCTION (TYP.) � NO N I I LLSTAKE ZU DOWNSLOPE STREAM CROSSING LL 1) EROSION STONE TO BE "CLASS I" RIP -RAP UNLESS DESIGNATED DIFFERENTLY ON W -10 '� SLOPE CLASS "I " RIP RAP MIN. SEDIMENT TRAP CONSTRUCTION PLAN. TOP OF BANK PAM FLOWTAKE \ / 2.- 1 SIDE SLOPE 2) PIPE SIZE AND AMOUNT NEEDED TO BE DETERMINED BY ENGINEER ON CONSTRUCTION g * PAM (I OZ. ) FLOW o ----------- - - U OR SILT BAG. 8 * PLAN. o rn (I 0Z .) = - _ __ 12 , 5 ' / / \ 3) TEMPORARY STREAM CROSSING TO BE CONVERTED TO COG #214 UPON PROJECT w - - MIN. MIN CONSTRUCTION COMPLETION IF CALLED FOR ON THE CONSTRUCTION PLANS. -_ 4) PUMP AND LINE SIZE TO BE DETERMINED BY THE CONTRACTOR USING THE BASE FLOW - - - -- ::.,......- ............._... SHOWN ON THE CONSTRUCTION PLANS. ............... .................................. A 5 WIDTH OF CONSTRUCTION EASEMENT SHALL BE MINIMIZED BASED UPON FIELD CONDITIONS. STREAM o SEE INSET B MATTING -:.-::: u-:::::::::::::::::::::::::::::::: ANY DISTURBANCE(5) EXCEEDING 40 MAY REQUIRE ADDITIONAL WATER DUALITY PERMITTING FLOW - - - - = OR MI TIGA TION 2' MIN. � MIN 6 . -,. _.._...... W a O _.............................. CONSTRUCTION SEQUENCE FOR STREAM CROSSING STREAM FL OW f 1 ) INSTALL PUMP AND LINE TO PUMP FLOW FROM AREA UPSTREAM OF TEMPORARY STREAM I I GIN PUMPING AND CROSSING TO AREA DOWNSTREAM OF CONSTRUCTION AREA. BE NA TURA L TOP VIEW ' TEMP. 24 " TO 5 MIN 2) CONTINUING PUMPING WHILE WORKING WITHIN THE STREAM. INSTALL UPSTREAM DAM, FIL TER FABRIC, AND TEMPORARY CMP. COVER PIPE INLET GROUND Q RIP -RAP TYPICAL - CROSSING 42" CMP - - - - - - - - - - - - - - - - - 2' CLASS "A" /L-� 10' 10' WITH FABRIC AND SAND BAGS AS SHOWN IN INSET "A" WHILE WORKING IN THE STREAM. "B" PIPE PAM CLASS "I " CROSSING EROSION' CONTROL / \ X DEWATERING BASIN ALLOW STREAM FLOW THROUGH CMP AS SHOWN IN INSET WHEN NOT WORKING WITHIN THE STREAM. SYNTHETIC FILTER (2 OZ .) RIP RAP PIPE STONE' WEIR e 2.' 1 SIDE SLOPE FABRIC PROPOSED 20 10 , MIN. OR SILT BAG. 3) INSTALL DOWNSTREAM TEMPORARY STONE DAM AND FIL TER FABRIC TO PREVENT BACK FLOW INTO CONSTRUCTION AREA. PLAN EARTH BERM (TYP.) 50' CONSTRUCTION EASEMENT 4) INSTALL PROPOSED EARTH BERMS ALONG TOP OF BANK ON EACH SIDE OF THE (SEE NOTE 5) CONSTRUCTION AREA. PROPOSED 5) INSTALL DEWATERING BASIN OR SILT BAG AT TOP OF BANK. DEWATER CONSTRUCTION TOP OF BANK RIP RAP SHALL NOT EAR(TTHYPBERM PLAN AREA BETWEEN TEMPORARY DAM USING THIS BASIN. OOV DRAINAGE DITCH EX ENDWA ABOVE .) TERANORMAL OR SMALL STREAM HIGH PK STAKES POLYETHYLENE FABRIC ON FACE (8 AL. THICK) 5) INSTALL THE 10' X 10' SEDIMENT TRAP OR SILT BAG. AM STAPLES PAM (iPOZ.) 0 OZ.) 12' MN. TOP OF FROM 7) UPON CONSTRUCTION COMPLETION, REMOVE TEMPORARY DAMS, FIL TER FABRIC, AND PTO UMP BAN_K PUMP TEMPORARY CMP. DEPRESS TEMPORARY DAM BOTTOMS INTO STREAM BED UNTIL TOP OF FIL INSET A INSET B INSET C _ _ / _ _ _ _ _ _ _ _ _ _ _ _ _ _ RIP RAP IS LEVEL WITH STREAM BOTTOM. CONVERT TO COG STANDARD #214 IF CALLED EX. IN r 1 FABRIC -� FOR IN THE CONSTRUCTION PLANS. CREEK S'�o� _ - ... ,'. NCDOT SPEC #1055,, SIRE9 y:;_: ;;;;::::` ::: ;;: FLIle7 TEMP. 24" TO 8) UPON STABILIZATION OF CLEARED AREAS, REMOVE TEMPORARY EARTH BERM, SEDIMENT F TYPE-2) NOTES.' � A lug , \ 42 " CMP TRAP, AND DEWA TERING BASIN. 1. 2. USE MINIMUM X RWATT I I UM 12" DIA EXCEL LE USE 2 F7 WOODEN STAKES WITH A 2 " X 2 " NOMINAL CROSS SECTION. ......... 2:: B" TA: _........................_............._... MIN. .- C OSSI G I E CROSSING PIPE 3. ONLY INSTALL WATTLE(5) IN DITCH SUCH THAT FLOW' PASSES OVER THE WEIR FORMED , ..:_ .-:.:'.'.:.TEMP - - - - IN THE CENTER OF THE WATTLE AND NOT AROUND THE WATTLE TO PREVENT BANK EROSION. -` '- ` - � " • ` ---- EX. INV. /� ORARY _ -' - ---- -- - - - 4. INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE STAKES A AN ANGLE TO WEDGE WATTLE TO BOTTOM OF DITCH. - CREEK STONE DAM 18 " CLASS I 5. PROVIDE STAPLES MADE OF 0. 125" DIA. STEEL WIRE- FORMED INTO A ° �� POL YETHYLENE FABRIC ON FACE (8 ML. THICK) RIP -RAP U SHAPE NOT LESS THAN 12" IN LENGTH. L L 5. INSTALL STAPLES APPROXIMATELY EVERY 1 LF ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. / CROSSING SECTION A -A 7. INSTALL MATTING IN ACCORDANCE WITH SECTION 1531 OF THE STANDARD SPECIFICATIONS. / : • \ PIPE o 0 8. PRIOR TO POLYACRYLAMIDE (PAM) APPLICATION, OBTAIN A SOIL SAMPLE FROM PROJECT o I o o NOTES: L OCA TION AND FROM ANY OFFSI TE BORROW MA TERIAL L. ANAL YZE FOR APPROPRIA TE PAN, N N N FLOCCULANT TO BE APPLIED TO EACH WATTLE. a \;::::::::.:::: .: a E 1) PERMANENT CROSSING FOR VEHICLE MAINTENANCE EQUIPMENT. 9. o INTIALL Y APPL Y 2 OUNCES OF ANIONIC OR NEUTPA LL Y CHARGED PAM OVER WATTLE WHERE WATER WILL FLOW AND 1 OUNCE OF PAM ON MATTING ON EACH SIDE OF WATTLE. REAPPLY w \ ' • - ' :_ '::1 INSTALL SANDBAGS IN PIPE INVERT 6 FABRIC WHILE PUMPING w 2) CLASS IRIP-RAP TO BE LAID MIN. 18 INCHES THICK OVER ENTIRE AREA OF DISTURBANCE ` PAN, AFTER EVERY RAINFALL EVENT THAT IS EQUAL 70 OR EXCEEDS 0. 50 ". ..•:; :".,- `;::_:'j A AROUND DURING CONSTRUCTION IN STREAM. d (AS DIRECTED BY ENGINEER). 10. L ONLY POL YACRYLAMIDES FROM THE NC-DWQ APPROVED LIST ARE TO BE USED. ANY OTHER PROPOSED FLOCCULANT REQUIRES REVIEW 6 APPROVAL BY THE OWO AQUATIC a = POLYETHYLENE FABRIC a a 3) CLASS II RIP -RAP USED IN LARGER STREAMS (AS DIRECTED BY ENGINEER) . TOXICOLOGY UNIT. w ON FACE (8 ML. THICK) B REMOVE SANDBAGS 6 FABRIC TO ALLOW FLOW THROUGH PIPE WHEN NOT PUMPING AROUND. W 1 W 4) AS PROJECT IS STABILIZED PLACE SYNTHETIC FIL TER FABRIC 6 SPREAD ALL EXISTING 11. WATTLES SHOULDSPACED IN DITCH USING THE FORMULA: [WATTLE DIA. (FT)) X 1001 /SLOPE (%) EROSION STONE INTO PERMANENT LINER AS SHOWN. ADD STONE AS NEEDED. = 12. WATTLE MATTING IS NOT REQUIRED ON DITCH LINES WHERE COMPLETE MATTING N Y SECTION A -A Y Y 5) ANY REQUIRED ARMORING ABOVE NORMAL HIGH WATER MARK SHALL CONSIST OF IS INDICATED ON THE PLANS. 1 OF 2 2 OF 2 3 MATTING OR APPROVED VEGETATIVE COVER. oINSTALLATION PAGE 2 OF 2 3 �w..N►�„�i+''+, c C/T Y OF GREENSBORO L C/T Y OF GREENSB0R0 Y OF GREENSBORO L �C/T Y OF GREEHSBORO a �C/T ,.•••�cN.�cgRo a�-04 , N STD. NO. REV. STANDARD TEMPORARY CREEK STD. NO. REV. STANDARD TEMPORARY CREEK STD. N0. REV. STANDARD PERMANENT CREEK STABILIZATION STD. NO. REV. oF�SS/ z Q� a WATTLE WITH POLYACRYLAMIDE (PAM) 12/10 u CROSSING DURING CONSTRUCTION 01-9105-05 03-97 09-05 CROSSING DURING CONSTRUCTION 01-9106-05 03-97 214 01-9105-05 ' 457 W 21,3 W 213 09-05 w WITH MAINTENANCE CROSSING 03-97 03-05 03-05 s O03-05 ''•.,�qs �GIN�c��C 1.. M.YA.� HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE ROADWAY SEWER WATER 100% SUBMITTAL SIDEWALK CONTRACT ICONTRACTORI AS -BUILT I AUTH . DATEI WATER AND SEWER PERMITS 2022-013C JOB NO. P- 05808C DESIGNED 11/2022 BY HDR CONST. SURVEY BY CHECKED BY DTB SCALE: AS NOTED K- CITY OF GREENSBORO 04D-13 WATER RESOURCES DEPARTMENT GRMS Phase IV Sewer Force Main Extension SHEET NO. STANDARD EROSION CONTROL DETAILS 40 OF 43 "" r_T GRATE 1'-0" (TYP) INSTALL STRAW EROSION CONTROL MATTING THIS PART OF SLOPE ORIGINAL CATCH BASIN SUSPENSION CORD/RODS PLANTED TO SHRUBS GROUND LINE AND GRASS a` co OVERFLOW 2 FILTER FABRIC SACK DEPTH VARIES FILL Ld FRONT VIEW KEY MATTING /�� CREEK m T vJ INTO GROUND /�//\�//�/�\/ BOTTOM < 3, -6,� MINIMUM GEOTEXTILE OR NOTES: >JJ BEDDING MATERIAL AS NEEDED CATCH BASIN " 1. STRAW MATTING AND STAPLES AS SPECIFIED IN THE 2012 2' MINIMUM ° 1 REBAR IN HEM FOR BAG REMOVAL NCDOT STANDARD SPECIFICATIONS SECTION 1060-8. ° \ 2. MAT SHALL BE STAPLED IN PATTERN AS SUGGESTED BY STORM PIPE RUBBER RESTRAINT MANUFACTURER. BLOCKS 2'-6" MINIMUM GRASS VEGETATED V-SWALE NOT TO SCALE NOTES r Lr\l'4 1. DO NOT EXCAVATE STREAMS WITH ROCK BOTTOMS IN ORDER TO PLACE ALL PIPES AT THE SAME LEVEL. PLACE AS MANY PIPES AS PRACTICAL WITHIN THE LOW AREA OF THE STREAM. PLACE REMAINING PIPES REQUIRED TO CROSS THE STREAM ON THE EXISTING STREAM BOTTOM. 2. INITIATE PUMP AROUND DIVERSION PRIOR TO ANY EXCAVATION IN STREAM. 3. STREAM CROSSING CAN ONLY BE IN PLACE FOR UP TO 4 MONTHS. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING WORK TO MEET THIS REQUIREMENT. 4. CONTRACTOR MUST MAINTAIN CROSSING. THIS INCLUDES KEEPING THE PIPES AND INLET AREA CLEAR OF DEBRIS TO MAINTAIN MAXIMUM WATER FLOW. #57 WASHED STONE 20 FT. MIN OACH LENGTH �'� �� TOP OF ROADWAY 1 /2 PIPE DIAMETER OR 12", WHICHEVER IS GREATER 5 FT. MAX. FILL HEIGHT FROM LOW POINT OF ORIGINAL CHANNEL IDTH BASED UIPMENT USED 8 IN. MIN DEPTH INSTALL NON -WOVEN GEOTEXTILE FABRIC BENEATH APPROACHES CLASS B RIPRAP PIPES SIZED TO ���/\�/� /�\�/' '� //�//�//�//.�ALL PIPE INVERTS SHOULD BE HANDLE FLOW RATE 12 IN. MAX LEVEL WITH THE LOW POINT OF BETWEEN PIPES ELEVATION ORIGINAL CHANNEL INSTALL NUMBER OF CULVERT PIPES REQUIRED TO SPAN CHANNEL 24" DIAMETER (MINIMUM) K0_4�TEMPORARY STREAM CROSSING DETAIL NOT TO SCALE SIDE VIEW TOP OF FRONT VIEW STREAM BANK STABILIZATION NOT TO SCALE 0 om H Z r~OmCn Fm—Iz�=D =-nDnm m = m 2Cn00 %j m I • OOH HOOD < U' o Z m 3 z n H � D F-I z Z D ao rD r > z H o Z m 0 m 1631.01 - -III-II III=111-= IIIIIII� III=III, 1111 III 1=III-III_ 1= 10" ( III III=III 4" III- -III=III=11 II -II -III I I -III- 1 � � III-III 4' II -III - I 111=11� I I II � II I I I I I- � 111,E I -III -I I -III-III IIIIIIIII__ 10' �� III -III -I STAPLE IIIIII` 6 IIIIIIIIIII�II CHECK ` II -III -III= MATTING IN DITCHES V47 10" 10 30B Staple ^^^^^ ^^^Check f"— 4 MATTING ON SLOPES SIUL VILW EXPANSION RESTRAINT TIE FILTER FABRIC SACK NOTES: 1. CURB INLETS AND COMBINATION CURB AND GRATE INLETS WILL REQUIRE THE USE OF A CURB INLET FILTER. CURB INLET FILTER SHALL BE THE "GUTTER EEL" AS MANUFACTURED BY ACF ENVIRONMENTAL, INC., OR EQUAL. CURB INLET FILTER, WHEN REQUIRED, WILL BE INSTALLED AT NO ADDITIONAL COST TO THE OWNER. 2. SIZE OF SACK TO BE DETERMINED BY MANUFACTURER TO SUIT I N LET. 3. INSTALL BAGS WITHOUT GAPS AT INLET GRATE. 4. FILTER FABRIC SACK SHALL BE "SILTSACK" MANUFACTURED BY ACF ENVIRONMENTAL, INC. INLET SEDIMENT PROTECTION DETAIL NOT TO SCALE 18" EXISTING (MIN.) GROUND BACKFILL 6" (MIN.) STAPLES ON 1' CENTERS Al OQ IN TRENCH yv 6" MIN MATTING SHALL BE STAPLES ON PLACED IN TRENCH 1' CENTERS AND BACKFILLED IN TRENCH DIAGRAM O 6 3' Staple X X N 3, X DIAGRAM (:� NOTES: THIS DETAIL APPLIES TO STRAW, EXCELSIOR, AND PERMANENT SOIL REINFORCEMENT MAT (PSRM) INSTALLATION. STAPLES SHALL BE NO. 11 GAUGE STEEL WIRE FORMED INTO A "U" SHAPE WITH A MINIMUM THROAT WIDTH OF 1 INCH AND NOT LESS THAN 6 INCHES IN LENGTH. EROSION CONTROL MATTING INSTALLATION NOT TO SCALE Staple Check Pattern 4„ Staple 7 4" DIAGRAM Q z 0� H } H Q Q LL J 0 0 W 2 Z Z w<<U_ < U O H (AHLLOJ O(!�a O u �> 1ui tz o Z CD � O �••� z � QI —I Q J tx J � Q Q N 0 Z Z ~ Q Cn Z H C H J Q z E w NOT TO SCALE SHEET 1 OF 1 1631.01 CONTRACT SHEET 41 OF 43 `.,• N CARO -04 oFess/p ¢EA z p �r /aok o?yq'G ►100 HDR Engineering, Inc. REVISIONS TYPE CONTRACT CONTRACTOR AS -BUILT AUTH. DAT WATER AND SEWER PERMITS JOB NO. P- 05808C CITY OF GREENSBOROof the Carolinas NCBELS License No. F-0116 WATER RESOURCES DEPARTMENT �4D_�g ROADWAY DESIGNED 11/2022 BY HDR 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 SEWER 2022-013C CONST. SURVEY BY GRMS Phase IV Sewer Force Main Extension SHEET NO. 704.338.6700 STANDARD EROSION CONTROL DETAILS WATER CHECKED BY DTB 41 OF 43 100% SUBMITTAL SIDEWALK SCALE: AS NOTED A 15"-16" TOP VIEW ......,...�.., � ..,..,.� 2' WOODEN STAKE DISTURBED AREA LINED DRAINAGE CLEAN WATER BYPASS. SEE SECTION THIS DETAIL FRONT VIEW SEE INSET A WATTLES ISOMETRIC VIEW 18" WATTLE PARALLEL TO 1AInDV 7nnI= SET 2" INTO EXISTING GRO' IN STANDARD 6.6' LINER WIDTH MAINTENANCE: • WATTLES SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT. • SEDIMENT DEPOSITS SHALL BE CLEANED FROM THE WATTLES WHEN IT REACHES HALF THE HEIGHT OF THE LOG. • DAMAGED WATTLES SHALL BE REPLACED WITHIN 24 HOURS OF INSPECTION. A SUPPLY OF WATTLES SHALL BE MAINTAINED ON SITE FOR THIS PURPOSE. NOTES: USE MINIMUM 18 IN. NOMINAL DIAMETER COIR FIBER (COCONUT) WATTLE AND LENGTH OF 10 FT. EXCAVATED A 2 TO 3 INCH TRENCH FOR WATTLE TO BE PLACED. DO NOT PLACE WATTLES ON TOE OF SLOPE. USE 2 FT. WOODEN STAKES WITH A 2 IN. BY 2 IN. NOMINAL CROSS SECTION. INSTALLED A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE STAKES AT AN ANGLE TO WEDGE WATTLE TO GROUND. PROVIDE STAPLES MADE OF 0.125 IN. DIAMETER STEEL WIRE FORMED INTO A U SHAPE NOT LESS THAN 12" IN LENGTH INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. FOR BREAKS ALONG LARGE SLOPES, USE MAXIMUM SPACING OF 25 FT. 3E FLOW CLEANWATER DIVERSION IN "U" SHAPE. SEE ISOMETRIC VIEW AIlITCC- 1. ALL SWALES TO BE LINED WITH NAG C125BN OR APPROVED EQUAL. TEMPORARY CLEANWATER DIVERSION NOT TO SCALE SECTION VIEW CONTRACT SHEET ,42 OF 43 `.,•N CARO :-04 oF�ss�p Q EA z 18 Iaok n Al. Yle,ptjA' HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE CONTRACT CONTRACTOR AS —BUILT AUTH. DAT WATER AND SEWER PERMITS JOB NO. P— 05808C CITY OF GREENSBORO WATER RESOURCES DEPARTMENT 04D-09 ROADWAY DESIGNED 11/2022 BY HDR SEWER 2022-013C CONST . SURVEY BY GRMS Phase IV Sewer Force Main Extension STANDARD EROSION CONTROL DETAILS SHEET NO. WATER CHECKED BY DTB OF 142 43 100% SUBMITTAL SIDEWALK SCALE: AS NOTED PROJECT NARRATIVE THE PROPOSED PHASE IV SEWER FORCE MAIN EXTENSION PROJECT IS LOCATED IN RANDOLPH COUNTY, NORTH CAROLINA SOUTHEAST OF GREENSBORO AND WILL ENCOMPASS APPROXIMATELY 3.44 MILES OF NEW SEWER FORCE MAIN ALONG THE EXISTING RIGHT OF WAY OF JULIAN AIRPORT ROAD AND U.S. 421. PRIOR TO INITIATING TEMPORARY AND PERMANENT CONSTRUCTION PHASES ASSOCIATED WITH THE NEW UTILITY MAINS, THE CONSTRUCTION CONTRACTOR WILL INSTALL EROSION CONTROL MEASURES TO ENCOMPASS THE ANTICIPATED CONSTRUCTION LIMITS. AN AVOIDANCE AND MINIMIZATION OF DISTURBANCE APPROACH SHALL BE INCORPORATED IN THE SITING OF THE EROSION CONTROL MEASURES. EROSION CONTROL MEASURES ARE INDICATED HEREIN FOR PERMITTING USE ONLY BY NCDEQ. THE INITIAL PROJECT DURATION IS ANTICIPATED TO BE FOUR WEEKS FOR INSTALLATION OF EROSION CONTROL MEASURES WITH MAINTENANCE AS NEEDED DURING THE CONSTRUCTION OF THE UTILITY MAINS. GENERAL EROSION CONTROL NOTES 1. THE CONTRACTOR SHALL INSTALL ALL EROSION AND SEDIMENTATION CONTROL MEASURES AND DEVICES NECESSARY TO COMPLY WITH THE STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY (NCDEQ) AND APPLICABLE STATE AND LOCAL LAWS AND ORDINANCES, AND PREVENT STANDING WATER WITHIN PROJECT LIMITS, UNLESS OTHERWISE DIRECTED. 2. INSTALL CONSTRUCTION ENTRANCES AND ACCESS ROADS IN LOCATIONS SHOWN, IN ACCORDANCE WITH STATE STANDARDS AND WITH MINIMAL DISTURBANCE TO SURROUNDING VEGETATION AND TREES. CONTRACTOR SHALL RECEIVE PRIOR APPROVAL FROM ENGINEER BEFORE TREE REMOVAL FOR ACCESS ROAD CONSTRUCTION. WITHIN 30 DAYS AFTER CONSTRUCTION IS COMPLETED FOR WHICH ACCESS ROAD IS USED, AND UNLESS OTHERWISE APPROVED, CONTRACTOR SHALL REMOVE ALL REMNANTS OF THE ACCESS ROADS AND RETURN AREA TO AS GOOD AS OR BETTER CONDITION. ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BASED ON CONTRACTOR'S PRACTICES OR BY A REPRESENTATIVE OF CITY OF GREENSBORO OR OWNER'S ENGINEER AND WILL BE EMPLOYED WHERE DETERMINED NECESSARY BY ACTUAL SITE CONDITIONS. 3. ALL MATERIALS SPILLED, DROPPED, WASHED, OR TRACKED FROM VEHICLE OR SITE ONTO PUBLIC ROADWAY OR INTO STORM DRAIN MUST BE REMOVED. 4. ALL DITCH LINES DISTURBED DURING CONSTRUCTION SHALL BE STABILIZED BY THE CONTRACTOR. ON ALL NEW OR DISTURBED UNPAVED DITCHES, INSTALL A SOIL STABILIZATION MATTING (NAG S150, S15OBN OR APPROVED EQUAL) ON THE DITCH BOTTOM AND SIDE SLOPES. 5. PROVIDE SILT FENCE ADJACENT TO DITCHES AND AT THE TOE OF FILL SLOPES. ALSO, PROVIDE ADEQUATE MEASURES IN AREAS WHERE NATURAL VEGETATION DOES NOT PROVIDE A SUFFICIENT BUFFER AND AS DIRECTED BY THE ENGINEER. WHERE SILT FENCE AND TREE PROTECTION CONFLICT, STOP SILT FENCE AT TREE PROTECTION. 6. PROVIDE INLET SEDIMENT FILTER AT ALL NEW STORM INLETS. INLET PROTECTION MAY BE REQUIRED AT EXISTING INLETS IN THE EVENT SEDIMENT WILL RUN DOWNSTREAM TO AN EXISTING INLET. 7. PRIOR TO COMMENCING LAND DISTURBANCE ACTIVITY: a. THE LIMITS OF LAND DISTURBANCE SHALL BE CLEARLY AND ACCURATELY DEMARCATED WITH STAKES, FENCING, OR OTHER APPROPRIATE MEANS. THE LOCATION AND EXTENT OF ALL AUTHORIZED LAND DISTURBANCE ACTIVITY SHALL BE DEMARCATED FOR THE DURATION OF THE CONSTRUCTION ACTIVITY. NO LAND DISTURBANCE SHALL OCCUR OUTSIDE THE APPROVED LIMITS INDICATED ON THE APPROVED PLANS. b. ALL TREE PROTECTION FENCING SHALL BE INSTALLED, INSPECTED AND APPROVED BY THE INSPECTOR. TREES WITHIN THE PROTECTION AREAS MAY ONLY BE REMOVED WITH APPROVAL BY THEINSPECTOR. 8. COMPLY WITH THE FOLLOWING CONSTRUCTION SEQUENCE FOR EACH CONSTRUCTION PHASE: a. GRUBBING SHALL BE PERFORMED DURING PREDICTED PERIODS OF DRY WEATHER. b. EROSION CONTROL DEVICES AND STORMWATER MANAGEMENT DEVICES SHALL BE INSTALLED PRIOR TO ANY OTHER CONSTRUCTION AND WITHIN 24 HOURS OF GRUBBING. THIS MAY REQUIRE GRUBBING IN STAGES TO ENSURE EROSION CONTROL MEASURES ARE PUT IN PLACE PRIOR TO A RAIN EVENT. THE LOCATION OF SOME OF THE EROSION CONTROL DEVICES MAY HAVE TO BE ALTERED FROM THAT SHOWN ON THE APPROVED PLANS IF DRAINAGE PATTERNS DURING CONSTRUCTION ARE DIFFERENT FROM THE FINAL PROPOSED DRAINAGE PATTERNS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ACCOMPLISH EROSION CONTROL FOR ALL DRAINAGE PATTERNS CREATED AT VARIOUS STAGES DURING CONSTRUCTION. ANY DIFFICULTY IN CONTROLLING EROSION DURING ANY PHASE OF CONSTRUCTION SHALL IMMEDIATELY BE REPORTED TO THE ENGINEER. c. SILT FENCE SHALL BE INSTALLED WITHIN 24 HOURS OF GRUBBING AND LOCATED PER THE PLANS. THE CONTRACTOR SHALL REMOVE ACCUMULATED SILT WHEN THE SILT IS WITHIN 12" OF THE TOP OF THE SILT FENCE UTILIZED FOR EROSION CONTROL. 9. THE CONSTRUCTION OF THE SITE WILL COMMENCE WITH INSTALLATION OF EROSION CONTROL MEASURES SUFFICIENT TO CONTROL SEDIMENT DEPOSITS AND EROSION. ALL SEDIMENT CONTROL WILL BE MAINTAINED UNTIL ALL UPSTREAM GROUND WITHIN THE CONSTRUCTION AREA HAS BEEN COMPLETELY STABILIZED WITH PERMANENT VEGETATION OR PAVEMENTS. 10. FAILURE TO INSTALL, OPERATE OR MAINTAIN ALL EROSION CONTROL MEASURES WILL RESULT IN ALL. CONSTRUCTION BEING STOPPED ON THE JOB SITE UNTIL SUCH MEASURES ARE CORRECTED TO NORTH CAROLINA EROSION AND SEDIMENT CONTROL REGULATIONS. 11. A COPY OF THE APPROVED LAND DISTURBANCE PLAN AND PERMIT SHALL BE PRESENT ON THE SITE WHENEVER LAND DISTURBANCE ACTIVITY IS IN PROGRESS. 12. ALL EROSION AND SEDIMENT CONTROL MEASURES WILL BE CHECKED DAILY AND ANY DEFICIENCIES NOTED WILL BE CORRECTED BY THE END OF EACH DAY. ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES WILL BE INSTALLED IF DEEMED NECESSARY BY ON -SITE INSPECTION. 13. ON -SITE STOCKPILING OF SOIL IS ALLOWED WITHIN THE LIMITS OF DISTURBANCE SUBJECT TO PLACING APPROPRIATE EROSION CONTROL DEVICES TO PREVENT SOIL LOSS DURING RAIN EVENTS. LOCATIONS SHALL BE PRE -APPROVED BY THE INSPECTOR. 14. GROUND STABILIZATION SHALL BE ACHIEVED CONSISTENT WITH NCDEQ GENERAL PERMIT NCGO1000 EFFECTIVE AS OF AUGUST 2, 2011. WHERE LAND DISTURBING ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, ALL DISTURBED AREAS SHALL BE PROVIDED WITH TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER WITHIN 14 CALENDAR DAYS FROM THE LAST LAND DISTURBING ACTIVITY EXCEPT FOR ALL PERIMETER DIKES, SWALES, DITCHES, PERIMETER SLOPES, AND ALL SLOPES STEEPER THAN 3:1 (H:V), WHICH SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER WITHIN 7 CALENDAR DAYS FROM THE LAND DISTURBING ACTIVITY. THE CONTRACTOR SHALL REFER TO GENERAL PERMIT NCGO1000 FOR SPECIFIC CONDITIONS, EXEMPTIONS, AND DEFINITIONS FOR MEETING THESE STABILIZATION REQUIREMENTS. SEE TABLE 1. 15. SITE DISTURBED AREA = 14.76 ACRES. THE SITE IS LOCATED AT 35°54'07" N, 79°38'55" W. 16. PROVIDE NOTIFICATION TO ALL AFFECTED PROPERTY OWNERS PRIOR TO CONSTRUCTION, AS APPLICABLE. 17. EFFECTIVE OCTOBER 1, 2010, PERSONS RESPONSIBLE FOR LAND DISTURBING ACTIVITIES MUST INSPECT THE SEDIMENT AND EROSION CONTROL MEASURES ON A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. SELF -INSPECTION REPORTS ARE REQUIRED. A SAMPLE SELF -INSPECTION REPORT AS WELL AS DETAILS OF THE SELF -INSPECTION NCDEQ PROGRAM CAN BE FOUND ON THE LAND QUALITY WEB SITE: http://deq.nc.govlaboutldivisionslenergy-mineral-land-resources/erosion-sediment-control/forms 18. ANY OFF -SITE BORROW AND WASTE REQUIRED FOR THIS PROJECT MUST COME FROM A SITE WITH AN APPROVED EROSION CONTROL PLAN, A SITE REGULATED UNDER THE MINING ACT OF 1971, OR A LANDFILL REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT. TRASH/DEBRIS FROM DEMOLITION ACTIVITIES OR GENERATED BY ANY ACTIVITIES ON SITE MUST BE DISPOSED OF AT A FACILITY REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT OR PER DIVISION OF SOLID WASTE MANAGEMENT OR DIVISION OF WATER RESOURCES RULES AND REGULATIONS. [15A NCAC 4B .0110] EROSION MAINTENANCE REQUIREMENTS 1. SEDIMENT FENCE (SILT FENCE): a. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND IMMEDIATELY FOLLOWING A RAIN EVENT WHICH EXCEEDS 0.5 INCHES IN A 24-HOUR PERIOD. MAKE ANY REQUIRED REPAIRS BY THE END OF EACH DAY. b. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. c. REMOVE SEDIMENT DEPOSITS WHEN FENCE IS 1/3 BURIED WITH SEDIMENT OR AS ADVISED BY OWNER'S ENGINEER TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. d. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEAN OUT. e. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE. STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. 2. WATTLES: a. INSPECT CHANNELS FOR DAMAGE IMMEDIATELY FOLLOWING A RAIN EVENT WHICH EXCEEDS 0.5 INCHES IN A 24-HOUR PERIOD. b. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE WATTLE AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE WATTLE. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS BETWEEN WATTLES, INSTALL A PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL. c. REMOVE SEDIMENT ACCUMULATED BEHIND THE WATTLES AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STRAW WATTLE AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE WATTLE. 3. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT: a. INSPECT ON LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 2-INCH STONE. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. 4. ROCK OUTLET PROTECTION: a. INSPECT STONE ARRANGEMENT EVERY 7 CALENDAR DAYS AND IMMEDIATELY FOLLOWING A RAIN EVENT WHICH EXCEEDS 0.5 INCHES IN A 24-HOUR PERIOD. b. MAINTAIN SPECIFIED DIMENSIONS AND REMOVE SEDIMENT BUILDUP WHEN THE SEDIMENT LEVEL IS'/2 THE HEIGHT OF THE ROCKS. 5. INLET PROTECTION: a. INSPECT STONE ARRANGEMENT EVERY 7 CALENDAR DAYS AND IMMEDIATELY FOLLOWING A RAIN EVENT WHICH EXCEEDS 0.5 INCHES IN A 24-HOUR PERIOD. b. REPLACE STONE AS NEED TO MAINTAIN SPECIFIED DIMENSIONS c. REMOVE SEDIMENT BUILDUP WHEN THE SEDIMENT LEVEL IS'/2 THE HEIGHT OF THE ROCKS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL 6. TEMPORARY DIVERSIONS: a. INSPECT EVERY 7 CALENDAR DAYS AND IMMEDIATELY FOLLOWING A RAIN EVENT WHICH EXCEEDS 0.5 INCHES IN A 24-HOUR PERIOD. REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGES. ALSO CHECK AND MAINTAIN OUTLETS. b. WHEN THE PROTECTED AREA IS PERMANENTLY STABILIZED, REMOVE THE RIDGES AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE SITE. 7. CHECK DAM: a. INSPECT CHECK DAMS AND CHANNELS FOR DAMAGE IMMEDIATELY FOLLOWING A RAIN EVENT WHICH EXCEEDS 0.5 INCHES IN A 24-HOUR PERIOD. b. ANTICIPATE SUBMERGENCE AND DEPOSITION ABOVE THE CHECK DAM AND EROSION FROM HIGH FLOWS AROUND THE EDGES OF THE DAM. CORRECT ALL DAMAGE IMMEDIATELY. IF SIGNIFICANT EROSION OCCURS BETWEEN DAMS, INSTALL A PROTECTIVE RIPRAP LINER IN THAT PORTION OF THE CHANNEL. c. REMOVE SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO CHANNEL VEGETATION, ALLOW THE CHANNEL TO DRAIN THROUGH THE STONE CHECK DAM AND PREVENT LARGE FLOWS FROM CARRYING SEDIMENT OVER THE DAM. ADD STONES TO DAMS AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION. TEMPORARY AND PERMANENT NON LAWN SEEDING MEASURES A. GENERAL: 1. AFTER CONSTRUCTION IS COMPLETE IN ANY AREA OR PHASE OF THE PROJECT, THE DISTURBED AREAS SHALL RECEIVE A PERMANENT GROUND COVER. SEEDING AND MULCHING SHALL BE PERFORMED IMMEDIATELY BEHIND CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE PERMANENT SEEDING IN ALL DISTURBED AREAS AS INDICATED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL ADAPT PERMANENT SEEDING OPERATIONS TO PROTECT AND TO ACCOMMODATE ANY TEMPORARY SEEDING AND SOIL AND EROSION CONTROL MEASURES THAT MAY ALREADY BE IN PLACE DURING THE WORK PERIOD. 2. WHEN SEEDING MUST TAKE PLACE OUT OF SEASON FOR PERMANENT GRASS THE APPROPRIATE TEMPORARY SEEDING SHALL BE DONE AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR PERMANENT SEEDING AS SPECIFIED IN SEASON AT NO ADDITIONAL COST TO OWNER. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR TURF MAINTENANCE THROUGH SUBSTANTIAL COMPLETION. SLOPES MUST BE AT 90% COVERAGE AT SUBSTANTIAL COMPLETION REVIEW TO BE ACCEPTED. IF NOT AT 90% COVERAGE, SUBSTANTIAL COMPLETION WILL BE DELAYED UNTIL THE FOLLOWING GROWING SEASON. B. SITE PREPARATION AND INSTALLATION: 1. GROUND COVER: ALL DISTURBED AREAS SHALL BE DRESSED TO A DEPTH OF SIX (6) INCHES. THE TOP THREE (3) INCHES SHALL BE PULVERIZED TO PROVIDE A UNIFORM SEEDBED. RAKE OR HARROW THE SITE TO ESTABLISH A SMOOTH AND LEVEL FINAL GRADE. SOIL PARTICLES SHOULD BE NO LARGER THAN MARBLE SIZE, AND PEA GRAVEL SIZE IS RECOMMENDED. AGRICULTURAL LIME SHALL BE APPLIED AT THE RATE OF 1 TONS/ACRE IMMEDIATELY BEFORE PLOWING. GRASS SEED SHALL BE APPLIED AT THE RATES OUTLINED IN TABLES 2A AND 2B. 2. 10-10-10 FERTILIZER SHALL BE APPLIED TO ALL DISTURBED AREAS AT A RATE OF 750 LBS./ACRE. MULCHING SHALL CONSIST OF SMALL GRAIN STRAW APPLIED AT A RATE OF 2 TONS/ACRE. MULCHED AREAS SHALL BE TACKED WITH AN APPROVED METHOD SUFFICIENT TO HOLD THE STRAW IN PLACE, AT A RATE OF 150 TO 200 GALLONS PER TON OF STRAW. 3. SOME AREAS MAY REQUIRE TEMPORARY SEEDING DUE TO AN INTERRUPTION OF WORK OR SEASONAL RESTRICTIONS AS SPECIFIED IN THE PERMANENT SEEDING SCHEDULE, OR A COMBINATION THEREOF. THESE AREAS SHALL BE RE -SEEDED IN ACCORDANCE WITH THE PERMANENT SEEDING SCHEDULE. IF TEMPORARY SEEDING IS REQUIRED DUE TO CONTRACTOR DELAYS, THERE WILL BE NO COMPENSATION FOR THE TEMPORARY SEEDING. TEMPORARY SEEDING SHALL BE PERFORMED ONLY AT THE DIRECTION OF THE ENGINEER OR INSPECTOR. C. CLEANUP AND INSPECTION: 1. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL REMOVE FROM THE SITE ALL EQUIPMENT AND OTHER ARTICLES USED. ALL EXCESS SOIL, STONE, AND DEBRIS SHALL BE REMOVED AND LEGALLY DISPOSED OF AT NO ADDITIONAL COST TO THE OWNER. ALL WORK AREAS SHALL BE LEFT IN A CLEAN AND NEAT CONDITION. ALL DAMAGE TO EXISTING CONSTRUCTION CAUSED BY LANDSCAPING OPERATIONS SHALL BE REPAIRED TO THE SATISFACTION OF THE TOWN AT THE CONTRACTOR'S EXPENSE. 2. SEEDED AREAS SHALL BE PROTECTED AND REPLANTED AS NECESSARY TO ESTABLISH A UNIFORM STAND OF SPECIFIED GRASS. SCATTERED BARE SPOTS, NONE OF WHICH SHALL BE LARGER THAT ONE (1) SQUARE FOOT, WILL BE ALLOWED UP TO A MAXIMUM OF 3% OF THE SEEDED AREA FOR EACH PROPERTY. WHEN SEEDED AREAS ARE READY FOR INSPECTION, THE MAINTAINED TURF AREAS SHALL BE NEATLY MOWED TO THE UNIFORM HEIGHT OF APPROXIMATELY FOUR (4) INCHES. THE LAWNS SHALL BE CONSIDERED ESTABLISHED ONLY WHEN THE SPECIFIED GRASS IS VIGOROUS AND GROWING WELL IN ADDITION TO MEETING THE OTHER REQUIREMENTS SPECIFIED. 3. AN INSPECTION OF THE COMPLETED SEEDING SHALL BE MADE AT THE CONCLUSION OF THE LANDSCAPE WORK UPON WRITTEN NOTICE REQUESTING SUCH INSPECTION SUBMITTED BY THE CONTRACTOR TO THE ENGINEER, AT LEAST TEN (10) DAYS PRIOR TO THE ANTICIPATED DATE OF INSPECTION. 4. A FINAL INSPECTION SHALL BE PERFORMED WHEN A SATISFACTORY STAND OF SEEDED TURF GRASS HAS BEEN PRODUCED, UPON WRITTEN NOTICE REQUESTING SUCH INSPECTION SUBMITTED BY THE CONTRACTOR TO THE ENGINEER, AT LEAST TEN (10) DAYS PRIOR TO THE ANTICIPATED DATE OF INSPECTION. IF A SATISFACTORY STAND OF TURF HAS NOT BEEN PRODUCED AT THE TIME OF FINAL INSPECTION, NECESSARY REPAIRS SHALL BE PERFORMED IN CONFORMANCE WITH THE REQUIREMENTS OF THIS SECTION. UPON COMPLETION OF THESE REPAIRS, THE SEEDED GRASS SHALL BE REINSPECTED UPON WRITTEN NOTICE AS ABOVE. 5. THESE NOTES ARE GENERAL. THE CONTRACTOR SHALL COMPLY WITH ANY AND ALL NCDEQ SEDIMENT AND EROSION CONTROL REQUIREMENTS FOR PROJECT CLOSEOUT. TABLE 2A SHOULDERS, SIDE DITCHES, SLOPES (For Slopes Between 2:1 and 3:1) Date Type Planting Rate Kobe Lespedeza (scarified) 50 lbs./acre Mar 1 -June 1 and Add Tall Fescue 120 lbs./acre Mar 1 - Apr 15 or Mar 1 - June 30 Add Hulled Common Bermudagrass 25 lbs./acre -Tall Fescue and 120 lbs./acre June 1 - Sept 1 ""*Brovvntop Millet or 35 lbs./acre ***Sorghurn-Sudan Hybrids 30 lbs./acre Kobe Lespedeza (unhulled/unscarified) 70 lbs./acre Sept 1 -Mar 1 and Tall Fescue 120 lbs./acre Nov 1 - Mar 1 Add Abruzzi Rye 25 lbs./acre TABLE 2B SHOULDERS, SIDE DITCHES, SLOPES (For Slopes 3:1 and Flatter) Date Type Planting Rate Aug 15 - Nov 1 Tall Fescue 300 lbs./acre Nov 1 - Mar 1 Tall Fescue and Abruzzi Rye 300 lbs./acre Mar 1 - Apr 15 Tall Fescue 300 lbs./acre Apr 15 - June 30 Hulled Common Bermudagrass 25 lbs./acre w Tall Fescue and ***Brontop Millet 35 lbs./acre July 15 -Aug 15 or ***SorghurrrSudan Hybrids "NOTE: SUBSTITUTE GRASS SEED MIXTURES MUST BE REVIEWED AND APPROVED BY THE ENGINEER. PERMANENT LAWN SEEDING MEASURES A. GENERAL 1. THE FOLLOWING INFORMATION SHALL BE APPLICABLE FOR ALL PERMANENT LAWN SEEDING. PERMANENT LAWN SEEDING SHALL TAKE PLACE WITHIN ALL DEVELOPED AREAS OF DISTURBANCE AND SHALL BE REPLACED IN KIND OF EXISTING MATERIAL BY THE CONTRACTOR. AN APPROVED TURF TYPE TALL FESCUE BLEND SHALL BE USED PER THE CONTRACT DOCUMENTS. KENTUCKY 31 FESCUE IS NOT AN ACCEPTABLE BLEND. 2. WHEN SEEDING MUST TAKE PLACE OUT OF SEASON FOR PERMANENT GRASS THE APPROPRIATE TEMPORARY SEEDING SHALL BE DONE AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR PERMANENT SEEDING AS SPECIFIED IN SEASON AT NO ADDITIONAL COST TO OWNER. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR LAWN MAINTENANCE THROUGH SUBSTANTIAL COMPLETION. LAWNS MUST BE AT 90% COVERAGE AT SUBSTANTIAL COMPLETION REVIEW TO BE ACCEPTED. IF NOT AT 90% COVERAGE, SUBSTANTIAL COMPLETION WILL BE DELAYED UNTIL THE FOLLOWING GROWING SEASON. B. SITE PREPARATION: 1. REMOVE OR KILL ANY UNDESIRABLE EXISTING TURF OR VEGETATION. HERBICIDE SPRAYING OR OTHER CHEMICAL TREATMENT SHALL BE APPROVED BY THE ENGINEER PRIOR TO BEING USED BY THE CONTRACTOR. IF PREEXISTING TURF OR OTHER VEGETATION IS MIXED WITH THE SOIL TO BE REUSED, THE CONTRACTOR SHALL USE BEST JUDGEMENT IN REMOVING IT OR INCORPORATING IT INTO THE SOIL DURING PREPARATION. 2. IF TOPSOIL WAS NOT USED TO REESTABLISH THE UPPER SOIL LAYER AND THE UPPER SOIL IS HEAVY WITH HIGH CLAY CONTENT, SPREAD 1.5-2 INCHES OF AGED GROUND PINE BARK OR BAGGED ORGANIC HUMUS OVER THE AREA TO BE REPAIRED. 3. FOR ALL GRASSES EXCEPT CENTIPEDEGRASS, APPLY PER 1,000 SQUARE FEET: 75 POUNDS OF GROUND LIMESTONE AND ONE OF THE FOLLOWING FERTILIZERS: 40 POUNDS OF 5-10-10; 20 POUNDS OF 10-20-20; OR 20 POUNDS OF 8-8-8 OR 10-10-10 IN COMBINATION WITH 4 POUNDS OF 0-46-0. CENTIPEDEGRASS PREFERS ACIDIC SOILS AND LOW LEVELS OF PHOSPHORUS AND MAY NOT REQUIRE THE ADDITION OF LIME AND PHOSPHORUS. 4. INCORPORATE LIME AND FERTILIZER (AND PINE BARK IF ADDED) INTO THE TOP 6 INCHES OF THE SOIL USING A ROTOTILLER OR BY HAND. ROTOTILL OR HAND CULTIVATE TO WELL INCORPORATE THE AMENDMENTS AND GET A UNIFORM LOOSELY TEXTURED SOIL OF MINIMUM 6-INCH DEPTH. 5. RAKE OR HARROW THE SITE TO ESTABLISH A SMOOTH AND LEVEL FINAL GRADE. SOIL PARTICLES SHOULD BE NO LARGER THAN MARBLE SIZE, AND PEA GRAVEL SIZE IS RECOMMENDED. HAND RAKING TO LEVEL THE SOIL AND WORK OUT HILLS AND HOLLOWS. FOR AREAS LARGER THAN 100 SQ. FT. ALLOW RAIN OR IRRIGATE TO SETTLE THE SOIL. IN SOME SITUATIONS, THE ENGINEER MAY REQUIRE ROLLING OR CULTIPACKING TO FIRM THE SOIL BEFORE SEEDING. HAND RAKE AGAIN TO BREAK UP THE CRUSTY SURFACE BEFORE SEEDING OR PLANTING. C. INSTALLATION: 1. GENERAL: a) SEED OR PLANT THE REQUIRED GRASS ACCORDING TO TABLE 3. b) THE CHOICE OF TURFGRASS TYPE, VARIETY AND PROPAGATION FORM SHALL BE SPECIFIED IN THE CONTRACT DOCUMENTS, AS SPECIFIED IN THE ITEMIZED PROPOSAL, OR AS DESIGNATED BY THE ENGINEER. c) SEED SHALL BE TAGGED CERTIFIED SEED. GERMINATION SHALL BE A MINIMUM OF 95%. SEED SHALL BE 98% PURE WITH LESS THAN 2% OTHER -CROP SEED OR DEBRIS. SEED SHALL BE FREE OF NOXIOUS WEED SEED. d) SOD, SPRIGS, PLUGS OR OTHER VEGETATIVE PLANT PROPAGATION MATERIALS SHALL BE CERTIFIED FREE OF NOXIOUS WEEDS. MATERIALS SHALL BE IN GOOD HEALTH AND VIGOR, FREE OF DISEASE OR PESTS, OR DAMAGE FROM DRYNESS, ADVERSE TEMPERATURE, HERBICIDES, FERTILIZER OR OTHER CHEMICALS. SPRIGS THAT ARE OLDER THAN 48 HOURS ARE NOT ACCEPTABLE REGARDLESS OF CONDITION. e) THE CONTRACTOR SHALL MAINTAIN A LOG OF DATES THAT SOD, SPRIGS, PLUGS, OR OTHER SEEDING INSTALLATION WAS COMPLETED FOR EACH INDIVIDUAL PROPERTY AND SHALL NOTIFY THE ENGINEER OR INSPECTOR OF EACH DAY'S PROGRESS. 2. SEEDING: a) SOW THE SEED ON FRESHLY PREPARED SOIL. ENSURE UNIFORM COVERAGE BY USING A CENTRIFUGAL (ROTARY) OR DROP -TYPE SPREADER. AREAS LARGER THAN 100 SQ. FT. SHALL BE SEEDED WITH A MINIMUM OF TWO PASSES AT THE APPROPRIATE PARTIAL RATE FOR EACH PASS. FOR AREAS AVERAGING GREATER 15 FT. WIDTH, APPLY HALF THE SEED IN ONE DIRECTION AND THE OTHER HALF AT RIGHT ANGLES TO THE FIRST DIRECTION. b) APPLY A STARTER -TYPE FERTILIZER TO THE SOIL SURFACE FOR EXAMPLE, 10 POUNDS OF 5-10-10 OR 5 POUNDS OF 10-20-20 PER 1,000 SQUARE FEET AT THE TIME OF SEEDING. c) LIGHTLY COVER THE SEED BY HAND RAKING OR DRAGGING WITH A MAT OR CHAIN -LINK FENCE. ROLL OR TAMP THE SOIL LIGHTLY TO FIRM THE SURFACE AND PROVIDE GOOD SEED -TO -SOIL CONTACT. d) MULCH GRASS SEED WITH WEED -FREE SMALL GRAIN STRAW OR HAY APPLIED AT A RATE OF 2 TONS/ACRE. STABILIZE SMALL AREAS OF MULCH BY ROLLING, WATERING OR TACKING WITH ASPHALT TACKING SPRAY. TWINE NETTING CAN BE USED IF WIND DISPLACEMENT IS A PROBLEM. IF APPLIED EVENLY AND LIGHTLY, THESE MATERIALS NEED NOT BE REMOVED. LARGER AREAS SHALL BE STABILIZED BY ASPHALT TACKING SPRAY OR TWINE NETTING. D. CLEANUP AND INSPECTION: 1. UPON COMPLETION OF WORK, THE CONTRACTOR SHALL REMOVE FROM THE SITE ALL EQUIPMENT AND OTHER ARTICLES USED. ALL EXCESS SOIL, STONE, AND DEBRIS SHALL BE REMOVED AND LEGALLY DISPOSED OF AT NO ADDITIONAL COST TO THE OWNER. ALL WORK AREAS SHALL BE LEFT IN A CLEAN AND NEAT CONDITION. ALL DAMAGE TO EXISTING CONSTRUCTION CAUSED BY LANDSCAPING OPERATIONS SHALL BE REPAIRED TO THE SATISFACTION OF THE TOWN AT THE CONTRACTOR'S EXPENSE. 2. SEEDED AREAS SHALL BE PROTECTED AND REPLANTED AS NECESSARY TO ESTABLISH A UNIFORM STAND OF SPECIFIED GRASS. SCATTERED BARE SPOTS, NONE OF WHICH SHALL BE LARGER THAT ONE (1) SQUARE FOOT, WILL BE ALLOWED UP TO A MAXIMUM OF 3% OF THE SEEDED AREA FOR EACH PROPERTY. WHEN SEEDED AREAS ARE READY FOR INSPECTION, THE MAINTAINED TURF AREAS SHALL BE NEATLY MOWED TO THE UNIFORM HEIGHT OF APPROXIMATELY TWO AND ONE-HALF (2.5) INCHES. THE LAWNS SHALL BE CONSIDERED ESTABLISHED ONLY WHEN THE SPECIFIED GRASS IS VIGOROUS AND GROWING WELL IN ADDITION TO MEETING THE OTHER REQUIREMENTS SPECIFIED. 3. AN INSPECTION OF THE COMPLETED SEEDING SHALL BE MADE AT THE CONCLUSION OF THE LANDSCAPE WORK UPON WRITTEN NOTICE REQUESTING SUCH INSPECTION SUBMITTED BY THE CONTRACTOR TO THE ENGINEER, AT LEAST TEN (10) DAYS PRIOR TO THE ANTICIPATED DATE OF INSPECTION. 4. A FINAL INSPECTION SHALL BE PERFORMED WHEN A SATISFACTORY STAND OF SEEDED TURF GRASS HAS BEEN PRODUCED, UPON WRITTEN NOTICE REQUESTING SUCH INSPECTION SUBMITTED BY THE CONTRACTOR TO THE ENGINEER, AT LEAST TEN (10) DAYS PRIOR TO THE ANTICIPATED DATE OF INSPECTION. IF A SATISFACTORY STAND OF TURF HAS NOT BEEN PRODUCED AT THE TIME OF FINAL INSPECTION, NECESSARY REPAIRS SHALL BE PERFORMED IN CONFORMANCE WITH THE REQUIREMENTS OF THIS SECTION. UPON COMPLETION OF THESE REPAIRS, THE SEEDED GRASS SHALL BE REINSPECTED UPON WRITTEN NOTICE AS ABOVE 5. THESE NOTES ARE GENERAL. THE CONTRACTOR SHALL COMPLY WITH ANY AND ALL NCDEQ SEDIMENT AND EROSION CONTROL REQUIREMENTS FOR PROJECT CLOSEOUT. TABLE 3 LAWN SEEDING (Cool- and Warm -Season Grasses) Typical Planting Rate/1,000 sq. ft. Lawn Grass Planting Dates' Seeds2 Space Planting3 Sprigginga March 1 to Oct. 15 6 - - Tall fescue (Aug. 15 to Oct. 1 optimum) Tall fescue/annual Oct. 15 to March 1 6 fescue (winter) rye 1 rye Bermudagrass(seed) Apr. 1 to Aug. 15 1 to 2 - - Bermudagrass (vegetative Apr. 15 to Aug. 30 - 5 a 5 Centipedegrass March to July 0.25 to 0.50 5 a Zoysiagrass April to July - 5 a 5 St. Augustinegrass Apr. to July - 5 a - 1. SOD CONSISTING OF COOL -SEASON GRASSES CAN BE INSTALLED ANYTIME THE GROUND IS NOT FROZEN. SOD CONSISTING OF WARM -SEASON GRASSES CAN BE INSTALLED AS LONG AS SOIL TEMPERATURE EXCEEDS 55°F (TYPICALLY APRIL 15 TO OCTOBER 1). 2. POUNDS OF SEED PER 1,000 SQ. FT. 3. SQ. YDS. TO TURF CUT INTO 2-INCH CENTERS TO PLANT 1,000 SQ. FT. 4. BUSHELS OF SPRIGS PER 1,000 SQ. FT. (1 SQ. YD. OF TURF PULLED APART IS EQUIVALENT TO 1 BUSHEL OF SPRIGS. TABLE I NCDEQ Stabilization Timeframes Site Area Description Stabilization Timeframe Exceptions Perimeter Dikes, swales, ditches and slopes 7 days None High Quality Water (HQW) Zones 7 days None Slopes Steeper than 3:1 7 days If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed Slopes 3:1 or Flatter 14 days 7 days for slopes greater than 50' in length All other areas with slopes flatter than 4:1 14 days None, except for perimeters and HQW zones NCDEQ SILT FENCE NOTE: 1. MAKE THE FENCE STABLE FOR THE 10-YEAR PEAK STORM RUNOFF. NCDEQ TABLE 6.52a: MAXIMUM SLOPE LENGTH AND SLOPE FOR WHICH SEDIMENT FENCE IS APPLICABLE SLOPE SLOPE LENGTH (FT) MAXIMUM AREA (FT ) < 2% 100 10,000 2 TO 5% 75 7, 500 5 TO 10% 50 5,000 10 TO 20% 25 2, 500 > 20% 15 1, 500 CONTRACT SHEET 43 OF 43 NOTE: THESE EROSION CONTROL NOTES ARE GENERAL AND EVERY NOTE MAY NOT BE APPLICABLE ON EVERY PROJECT. THE CONTRACTOR SHALL COMPLY WITH ALL NCDEQ SEDIMENT AND EROSION CONTROL REQUIREMENTS. 1. SCREENING OR SHADING OF WORK IS USED TO INDICATE EXISTING COMPONENTS OR TO DE-EMPHASIZE PROPOSED IMPROVEMENTS TO HIGHLIGHT SELECTED PHASED WORK. REFER TO CONTEXT OF EACH PHASE FOR USAGE. 2. SITE SHOWN USING LIDAR-BASED EXISTING TOPOGRAPHY r,ti°'i"oo" """+r, DATA. aa•aaa� O �►+�i 7 02 r S �� C! O� ••. M. YO F)l HDR Engineering, Inc. of the Carolinas NCBELS License No. F-0116 440 S. Church St., Suite 1200 Charlotte, NC 28202-2075 704.338.6700 REVISIONS TYPE CONTRACT CONTRACTOR AS -BUILT AUTH. DAT WATER AND SEWER PERMITS JOB NO. P- 05606C CITY OF GREENSBORO WATER RESOURCES DEPARTMENT 04D-10 ROADWAY DESIGNED 11/2022 BY HDR SEWER 2022-013C CONST . SURVEY BY GRMS Phase IV Sewer Force Main Extension EROSION CONTROL AND SEEDING SPECIFICATION SHEET NO. WATER CHECKED BY DTB 43 OF 43 100% SUBMITTAL SIDEWALK SCALE: AS NOTED