Loading...
HomeMy WebLinkAboutNCG110013_Inspection_20240712 ROY COOPER do Governor ELISABETH BISER i = Secretary WILLIAM E.TOBY VINSON,JR. ``"AM Interim Director NORTH CAROLINA Environmental Quality July 12, 2024 City of Winston-Salem Attention: Courtney Driver, Utilities Director PO Box 2511 Winston-Salem, NC 27107 Subject: Compliance Evaluation Inspection Archie Elledge WWTP NPDES Certificate of Coverage—NCG110013 Forsyth County, North Carolina Dear Sir or Madam, Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection we conducted at the Archie Elledge WWTP on July 10, 2024. Please note that in the stormwater inspection report summary we ask that you review preventative maintenance and good housekeeping practices and implement them as necessary. Additionally analyze and address any potential wastewater leaks. The report should be self-explanatory; however, should you have any questions, please do not hesitate to contact Margeory Castellanos at (336)776-9724 or by E-mail at Margeory.castellanos@deq.nc.gov. Sincerel,, Tamera Epli , PE Regional Engineer Land Quality Section Enclosure: Compliance Inspection Report c: Laserfiche North Carolina Department of Environmental Quality I Division of Energy,Mineral and Land Resources Winston-Salem Regional Office 1 450 Hanes Mill Road,Suite 300 I Winston-Salem,North Carolina 27105 kE 336-776-9800 Compliance Inspection Report Permit:NCG110013 Effective: 03/01/24 Expiration: 02/28/29 Owner: City of Winston-Salem SOC: Effective: Expiration: Facility: Archie Elledge WWTP County: Forsyth 2801 Griffith Rd Region: Winston-Salem Winston Salem NC 271036417 Contact Person:James F Crump Title: Phone:336-397-7625 Directions to Facility: System Classifications: SWNC, Primary ORC: Certification: Phone: Secondary ORC(s): On-Site Representative(s): Related Permits: Inspection Date: 07/10/2024 Entry Time 01:OOPM Exit Time: 02:45PM Primary Inspector:Margeory Castellanos Phone: 336-776-9800 Secondary Inspector(s): Ashley J Vikara Isaiah L Reed Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Municipal WWTP> 1 MGD, Stormwater Discharge, COC Facility Status: ❑ Compliant Not Compliant Question Areas: 0 Storm Water (See attachment summary) Page 1 of 3 Permit: NCG110013 Owner-Facility:City of Winston-Salem Inspection Date: 07/10/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Inspection Summary: On July 10, 2024, this facility was inspected for compliance.We met with Heath Petree on site. During the inspection, the following items were noted: 1. The SWPPP was found to be incomplete, lacking appropriately certified non-stormwater discharge evaluation and current list of spills (notation that no spills have occurred). 2. Biosolids material was observed spilling outside containment structure. Review preventative maintenance and good housekeeping practices and implement as necessary. 3.Haul road adjacent to biosolids storage area displayed several indicators of potential wastewater leak (visual and odor). Analyze and address appropriately. Please give the above items your immediate attention. If you have any questions, you can reach me at (336) 776-9724. Page 2 of 3 Permit: NCG110013 Owner-Facility:City of Winston-Salem Inspection Date: 07/10/2024 Inspection Type:Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? 0 ❑ ❑ ❑ #Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ 0 ❑ #Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ #Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? 0 ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? N ❑ ❑ ❑ #Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? N ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: See summary Qualitative Monitorinq Yes No NA NE Has the facility conducted its Qualitative Monitoring? N ❑ ❑ ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ❑ E ❑ ❑ #Were all outfalls observed during the inspection? ❑ 0 ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ 0 ❑ #Has the facility evaluated all illicit(non stormwater)discharges? ❑ 0 ❑ ❑ Comment: See summary Page 3 of 3